HomeMy WebLinkAbout2075 CORTE DEL NOGAL; J; CB012371; Permit08-16-2001
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB012371
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
08/16/2001
Applicant
GOOD & ROBERTS INC
1090 JOSHUA WAY
VISTA, CA 92083
619-598-7614
2075 CORTE DEL NOGAL CBAD St J
Tl Sub Type INDUST
2130610700 Lot# 0 Status
$40,00000 Construction Type NEW Applied
Reference # Entered By
QUAREX PHARMICEUTICALS-ADD 3
FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPMENTIssued
Inspect Area
ISSUED
07/12/2001
RMA
Plan Approved
08/16/2001
Owner
SAN-GAL TRUST
550 WCST #1820
SAN DIEGO CA 92101
7492 08/1.6/01 0002 OJ 02
CGP 382-99
Total Fees $577 07 Total Payments To Date $194 08 Balance Due $382 99
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$298 59 Meter Size
$0 00 Add'l Reel Water Con Fee
$19408 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$8 40 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$3500
$41 00
$000
$000
$000
$000
$577 07
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
1 PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK NO fffi/O \
EST VAL ty "
Plan Ck Deposit
Validated By
Date "7
iisjiAddress (include Bldg/Suite #)Business Name (at thisladdress)
Legal Description
Assessor s
Description
Parcel #
of Work
X f
Lot No Subdivision Name/Number Unit No Phase No Total # of units
4490 07/12/01 MO:> ni art
Existing Use
£/t>tfrj SO.FT
/
Proposed Use
#of Stones / # of yfiedrooms
CGP
/ /) #of
194
Bathrooms
.08
^,A/X) 3 ffae fttofis A^ teumzo
2 CONTACT PERSON (if different from applicant)
Name
3 ...... APPLICANT,;;;ntractor
Address
. Agent for Contractor
JLOU.S~Tf. fr ~^
Lj Owner'"'' fj 'Agent for
CltV
for Owner •:: i
rr
' State/Zip Telephone # Fax #
Name
4 PROPERTY OWNER
Address City State/Zip Telephone #
Address City State/Zip Telephone ffName
5! CONTRACTOR -COMPANY NAME : 1 "" '.. ..." if" -'. Jv:- • -''I ,'••'"V ' '!P\ ' ''3 "X,, -s •-"•:
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars |$500W
r^r^rO ^ Arrterrt OT^^ ^J^> C^^reAJ <?JT OJSTrt S^S^C,/*
Name
Stato License #
Address
License Class 6
City State/Zip
City Business License #
Telephone #
Designer Name Address City State/Zip Telephone
State License #
6 WORKERS71 COMPENSATION T ; ; ,
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
[~1 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued
^Bl I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance carrier and policy number are
Insurance Company .3 iffT^- F(J/\JJ Policy No ^j? 3 "^-3 XS"" O& Expiration Date ^
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000) in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney s fees
SIGNATURE (^j£j£^£ DATE ? - fL-~O/
7 OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
l~l I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
PI I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
D I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement (~l YES QNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)
PROPERTY OWNER SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY ,; ,:% V; _ % . ;J
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? fj] YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES l~l NO
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? Q YES Q NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8. > CONSTRUCTION LENDING AGENCY # , :,.,
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code)
LENDER'S NAME LENDER'S ADDRESS
9 r:S: APPLICANT CERTIFICATION - '" '"' •, '•• '" - :: •-.. ::-.. 3;: \"',; .. J -'"
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5'0 deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced for a periorJof 1^0 days (Section 106 4 4 Uniform Building Code)
APPLICANT'S SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad
Final Building Inspection
Dept- Building Engineering Planning CMWD St Lite cFire
Plan Check #
Permit #
Project Name
Address
Contact Person
Sewer Dist
Inspected^
By C
Inspected
Bv
Inspected
Bv
Comments <;
CB012371
QUAREX PHARMICEUTICALS-ADD 3
FUME HOODS,LIGHTS, ROOF MOUNTED A/C
2075 CORTE DEL NOGAL #J
CHUCK
CA
' /£- '.JJLJ-tdis
3T ^
Phone 7605987614
Water Dist CA
Date % /?7/niInspected ' ^'
Date
Inspected
Date
Inspected
- fi ^ f
Date
Permit Type
Sub Type
EQUIPM
Lot 0
\ L-
Approved
Approved
Approved
f $/?/- I
08/17/2001
Tl
INDUS!
Disapproved
Disapproved
Disapproved
City of Carlsbad
Final Building Inspection
Dept: Building Engineering
Plan Check #
Permit #
Project Name
Address
Contact Person
Sewer Dist
Inspectedxo
Inspected
Bv
Inspected
Bv
Comments
Planning CMWD St Lite QFire
Date
CB012371 Permit Type
QUAREX PHARMICEUTICALS-ADD 3 Sub Type
FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPM
2075 CORTE DEL NOGAL #J
CHUCK
CA
<C^z£^
rr t*
Phone 7605987614
Water Dist CA
Date tf/-?/
Inspected "/(flD
Date
Inspected
Date
Inspected
'•***£> fs?»*n/.
Lot 0
f Approved
Approved
Approved
\£J *f/?/M
08/17/2001
Tl
INDUST
.---
Disapproved
Disapproved
Disapproved
City of Carlsbad Bldg Inspection Request
For 09/11/2001
PermiW CB012371
Title QUAREX PHARMICEUTICALS-ADD 3
Description FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPMENT
Inspector Assignment TP
2075 CORTE DEL NOGAL
J Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT GOOD & ROBERTS INC
Owner PLETA TRUST
Remarks
Sub Type INDUST
Phone 6197193630
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By J P JONES
Entered By CHRISTINE
Act Comments
A?
Associated PCRs
Inspection History
Date Description Act Insp Comments
08/17/2001 89 Final Combo CO TP
City of Carlsbad Bldg Inspection Request
For 08/17/2001
Inspector AssignmentPermit# CB012371
Title QUAREX PHARMICEUTICALS-ADD 3
Description FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPMENT
2075 CORTE DEL NOGAL
J Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT GOOD & ROBERTS INC
Owner PLETA TRUST
Remarks
Sub Type INDUST
Phone 7605987614
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comments
Requested By CHUCK
Entered By CHRISTINE
Associated PCRs
Inspection History
Date Description Act Insp Comments
CITY OF CARLSBAD
BUILDING DEPARTMENT
DATE &/'?/*/
NOTICE
LOCATION
PERMIT NO
(760) 602-2700
1635 FARADAY AVENUE
TIME
'/
3
FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? i ! YES
FOR FURTHER INFORMATION, CONTACT -&C>Jt '
BUILDING INSPECTOR CODE ENFORCEMENT OFFICER
"NOTICECITY OF CARLSBAD (760) 602-2700
BUILDING DEPARTMENT 1635 FARADAY AVENUE
DATE A?'//If TIME
LOCATION
PERMIT NO
\
FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? ! _ i YES
FOR FURTHER INFORMATION, CONTACT £&£ "Z
PHONE
BUILDING INSPECTOR CODE ENFORCEMENT OFFICER
EsGil Corporation
In Partnership witfi. government for 'Bu.iUmg Safety
DATE August 16, 2001
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 01-2371 SET III
PROJECT ADDRESS 2075 Corte Del Nogal
PROJECT NAME QUOREX PHARMACEUTICALS
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed/
Person contacted Chuck Glynn Telephone #
Date contacted 8/16/01 (by Abe) Fax #
Mad Telephone Fax In Person XX
REMARKS Applicant to carry approved set of plans to the cityyOW by Mike P APPLICANT
WILL SLIP SHEET THE FOLLOWING SHEETS INTO THE C/TY PLAN SET. SHEETS A.1,
E1.1, E1.2, E2.1, E3.1, M3.1 andM4.1. Building Official to review the Fire Department
approval of the Revised Technical Report Hazardous jylaterials Summary dated August 1,
2001.
By Abe Doliente Enclosures
Esgil Corporation
D GA D MB D EJ D PC 8/16/01 trnsmtldot
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858) 560-1468 4 Fax (858) 560-1576
EsGil Corporation
In fartnersfiip wit ft Government for Quitting Safety
DATE August 14, 2001
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 01-2371 SET II
PROJECT ADDRESS 2075 Corte Del Nogal
PROJECT NAME QUOREX PHARMACEUTICALS
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
1X1 The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Good & Roberts Inc
2320 Coosteau Ct, Vista, CA 92083
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted ChuckGlynn— Telephone* 760/598-7614
Date contacted ^M (by 73) Fax # ILoO- ^S^fe
Mail Telephone -"Tax — In Person
REMARKS
By Abe Doliente Enclosures
Esgil Corporation
13 GA D MB D EJ D PC 8/6/01 tmsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
Carlsbad 01-2371 II
August 14, 2O01
RECHECK PLAN CORRECTION LIST
JURISDICTION Carlsbad PLAN CHECK NO 01-2371
PROJECT ADDRESS 2075 Corte Del Nogal SET II
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED
ESGIL CORPORATION 8/6/01 August 14, 2001
REVIEWED BY Abe Doliente
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
A Please make all corrections on the original tracings and submit two new sets of prints to
Esgil Corp ortothebldg dept of the juris
B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
C The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections Please contact me if you have any questions regarding these items
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
Q Yes a No
F Carlsbad 01-2371 II
August 14, 2001
1 All sheets of the plans including the SX sheets of the calculations shall be signed
and sealed/stamped by the Engineer Please include the license expiration date
and the date the plans are signed
3 Please see the following corrections for electrical, plumbing and mechanical
* PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
4 PLAN REVIEWER: Glen Adamek
I Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes Business and
Professions Code Sheet T1 is not signed? And sheet A1 is missing from
the new plan package.
3 Building Official to review the Fire Department approval of the Revised
Technical Report Hazardous Materials Summary dated August 1. 2001
MECHANICAL (1997 UNIFORM MECHANICAL CODE)
8 Correct the exhaust discharge clearances from exhaust fan EF-5 to show
the required minimum 3 feet from the exterior wall (parapet wall or screen
wall) and 3 feet from the roof, as per UMC, Section 505.9.
ENERGY CONSERVATION
10 The plans show an existing non-conditioned space now being conditioned
Provide the required envelope energy design calculations for this change in
envelope The response states the existing space is existing conditioned
space, but the plans do not show any existing HVAC equipment serving the
Research Area. Nothing shows existing HVAC being removed. Please
correct.
I1 On the plans clearly show the wall and roof insulation locations, thickness, and
R-values, as per the energy design See item #10 above.
12 The existing restroom opening into the newly conditioned space is also newly
conditioned space See item #10 above.
A) The new conditioned floor area is about 740 square feet Not the 665
square feet used
B) Please correct the lighting design to include the existing restroom now
being conditioned
F
™Carlsbad O1-2371 II
August 14, 2001
13 Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section
131(d) (5,000 square foot exemption has been eliminated-AB 970 energy
design change)
14 The corrected, completed and signed ENV-1, LTG-1, and MECH-1 forms must
be imprinted on the plans
15 The Documentation Author and the Principal Envelope Designer must sign the
corrected ENV-1 form
16 The Documentation Author and the Principal Lighting Designer must sign the
corrected LTG-1 form
17 The Documentation Author and the Principal Mechanical Designer must sign the
corrected MECH-1 form
18 Complete energy plan check will be done when complete corrected energy
designs are provided
Note: If you have any questions regarding this plumbing, mechanical and energy plan
review list please contact Glen Adamek at (858) 560-1468 To speed the review
process, note on this list (or a copy) where the corrected items have been
addressed on the plans
EsGil Corporation
In Partnership with government for "Building Safety
DATE July 27, 2001 Q APPLICANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 01-2371 SET I
PROJECT ADDRESS 2O75 Corte Del Nogal
PROJECT NAME QUOREX PHARMACEUTICALS
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X] The applicant's copy of the check list has been sent to
Good & Roberts Inc
2320 Coosteau Ct Vista, CA 92083
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Chuck Glynn (V.M.) Telephone # 760/598-7614
ft.-H-*>^e>/Date contacted ~?- z.*7-<" (by £**. ) Fax #
Telephone ^ Fax In Person
XI REMARKS T I includes addition of 3 hood fumes and related mechanical equipment with roof
mounted equipment
By Abe Doliente Enclosures
Esgil Corporation
[3 GA S MB D EJ D PC 7/16/01 trnsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576
Carlsbad 01-2371
July 27, 20O1
GENERAL PLAN CORRECTION LIST
JURISDICTION Carlsbad PLAN CHECK NO O1-2371
PROJECT ADDRESS 2075 Corte Del Nogal
DATE PLAN RECEIVED BY DATE REVIEW COMPLETED
ESGIL CORPORATION 7/16/01 July 27, 2001
REVIEWED BY Abe Doliente
FOREWORD (PLEASE READ)-
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
• Please make all corrections on the original tracings and submit two new complete sets of
prints to Esgil Corp ortothebldg dept of the juris
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
Q Yes Q No
Carlsbad O1-2371
July 27, 2001
1 All sheets of the plans including the SX sheets of the calculations shall be signed and
sealed/stamped by the Engineer Please include the license expiration date and the date
the plans are signed
2 Sheet 3 of the calculations calls for 4 X 16 purlins, but the sketches show 4X14 Please
clarify
3 Please see the following corrections for electrical, plumbing and mechanical
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to
perform the plan review for your project If you have any questions regarding these plan
review items, please contact Abe Doliente at Esgil Corporation Thank you
* ELECTRICAL PLAN REVIEW
* 1996 NEC
* PLAN REVIEWER: MORTEZA BEHESHTI
1 Show or note on the plans the method used to limit fault currents to 10,000 amps on new
branch circuits
2 Show exit signs on the lighting plan(s) at all required exits and specify them as being self-
luminous or having a second source of power (battery or generator) This is required when
two exits are required per the UBC UBC 1003 2 8 2 and NEC 700-16
3 In all occupancies where the exit system serves 100 or more occupants, provide a minimum
of 1 foot-candle of emergency illumination at the floor level and specify a second source of
power for the emergency illumination (battery or generator) UBC 1003 2 9 2 & NEC 700-
16
Note: If you have any questions regarding this electrical plan review list please contact Morteza
Beheshti at (858) 560-1468 To speed the review process, note on this list (or a copy)
where the corrected items have been addressed on the plans
* PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
* PLAN REVIEWER: Glen Adamek
1 Each sheet of the plans must be signed by the person responsible for their preparation,
even though there are no structural changes Business and Professions Code
2 The Technical Report Hazardous Materials Summary shows many of the materials are
only stored and not used? Why are the materials stored and not used?
Carlsbad 01-2371
July 27, 2O01
3 Building Official to review the Fire Department approval of the Technical Report
Hazardous Materials Summary
4 Specify the date of the building permit date of submittal for this project If after June 1,
2001, energy design based upon the AB970 revisions will be necessary See "Energy"
below
PLUMBING (1997 UNIFORM PLUMBING CODE)
5 Correct the plumbing plan sheet P2 1 to clearly show what is part of this permit and what
is "Under a Separate Permit'"? If sinks are not apart of this permit, then correct the air
conditioning unit condensate waste line to an approved existing fixture
MECHANICAL (1997 UNIFORM MECHANICAL CODE)
6 Clearly not on the plans the Class I, II, or III-A liquids are used only within operating fume
hoods as per the Technical Report Hazardous Materials Summary UBC, Section
120222
7 Show the location of the required roof access ladder to roof mounted HVAC equipment
UMC, Section 307 5
8 Detail exhaust ventilation system (fume hood systems) compliance with UMC Chapters 5
&6
a) Detail the exhaust outlet clearances as per UMC, Sections 504 6 & 505 9
b) Clearly show the type of material to be exhausted by each exhaust system
c) Separate and distinct systems shall be provided for incompatible materials UMC,
Section 505 2 The plans show only one exhaust system As per the
Technical Report Hazardous Materials Summary and UMC, Section 505.2,
more than one exhaust system is required.
d) Clearly show the duct materials are suitable for the intended use UMC, Section
6091
e) Clearly show the exhaust duct material and gage used for each duct size See
UMC, Table 5-B & 5-C
f) Detail minimum duct conveying velocities as per UMC, Section 505 4 and Table 5-
A
g) Detail required duct cleanouts as per UMC, Section 609 4
h) Detail duct support as per UMC, Section 609 6
i) Detail protection from physical damage as per UMC, Section 609 9
9 Ventilation air supply shall be sufficient to provide make-up air for exhaust systems when
required by this code or the Building Code Make-up air systems shall be electrically
interlocked with their associated exhaust systems UMC, Section 402 4 Heat Pump
HP-4 and fans EF-5 and SF-1 must all be electrically interlocked.
Carlsbad 01-2371
July 27, 2001
ENERGY CONSERVATION
10 The plans show an existing non-conditioned space now being conditioned Provide the
required envelope energy design calculations for this change in envelope
11 On the plans clearly show the wall and roof insulation locations, thickness, and R-values,
as per the energy design
12 The existing restroom opening into the newly conditioned space is also newly
conditioned space
a) The new conditioned floor area is about 740 square feet Not the 665 square feet
used
b) Please correct the lighting design to include the existing restroom now being
conditioned
13 Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131 (d)
14 The corrected, completed and signed ENV-1, LTG-1, and MECH-1 forms must be
imprinted on the plans
15 The Documentation Author and the Principal Envelope Designer must sign the corrected
ENV-1 form
16 The Documentation Author and the Principal Lighting Designer must sign the corrected
LTG-1 form
17 The Documentation Author and the Principal Mechanical Designer must sign the
corrected MECH-1 form
18 Complete energy plan check will be done when complete corrected energy designs are
provided
Note: If you have any questions regarding this plumbing, mechanical and energy plan review
list please contact Glen Adamek at (858) 560-1468 To speed the review process, note
on this list (or a copy) where the corrected items have been addressed on the plans
Carlsbad 01-2371
July 27, 2001
JURISDICTION Carlsbad
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO 01-2371
PREPARED BY Abe Doliente DATE July 27, 2001
BUILDING ADDRESS 2075 Corte Del Nogal
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION V-N
BUILDING
PORTION
T 1 (see below)
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
cb
Valuation
Multiplier
By Ordinance
Reg
Mod
VALUE ($)
40,000
40,000
Bldg Permit Fee by Ordinance jr
Plan Check Fee by Ordinance V
Type of Review
[J Repetitive Fee -,
Repeats
E Complete Review
D Other
n Hourly
D Structural Only
Hour*
Esgil Plan Review Fee
$298 59]
$194 08
$167.21
Comments Add 3 fume hoods and related mechanical equipment with roof mounted equipment
Sheet! of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB DATE
ADDRESS 5 CLA
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
(< $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
ENGINEE DATE
Docs/Mlsforms/Planmng Engineering Approvals
n
n
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check
Planner
APN
Address
Phone (760) 602- U/ 9-
Type of Project & Use
Zoning General Plan
Net Project Density _
Facilities Management Zone
DU/AC
CFD fin/nut» #
Circle One
Date of participation Remaining net dev acres
(For non-residential development Type of land used created by
this permit )
Legend X Item Complete
Environmental Review Required1
DATE OF COMPLETION
YES
Item Incomplete - Needs your action
NO TYPE
Compliance with conditions of approval7 If not, state conditions which require action
Conditions of Approval
Discretionary Action Required:
APPROVAL/RESO NO
PROJECT NO
YES NO TYPE
DATE
OTHER RELATED CASES
Compliance with conditions or approval7 If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone7 YES
CA Coastal Commission Authority? YES
NO_
NO
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt)
Coastal Permit Determination Form already completed7
If NO, complete Coastal Permit Determination Form now
Coastal Permit Determination Log #
YES NO
Foliow-Up Actions-
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans)
2) Complete Coastal Permit Determination Log as needed
H \ADMIN\COUNTER\BldgPlnchkRevChklst
I I Inclusionary Housing Fee required. YES NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 )
Data Entry Completed? YES NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE')
Site Plan.
1 Provide a fully dimensional site plan drawn to scale Show. North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines (including all side and rear yard slopes)
LJ \_j \_\ 2 Provide legal description of property and assessor's parcel number
D
Zoning-
I 1 Setbacks
Front
Interior Side
Street Side
Rear
Top of slope-
ill] \_\ 2 Accessory structure s«
Front
Interior Side
Street Side
Rear
Structure separation:
3 Lot Coverage
O 4 Height
Til n 5 Parking. Spaces
Required
Required
Required
Required
Required
Jtbacks
Required
Required
Required
Required
Required
Required
Required
Required
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
H \ADMIN\COUNTER\BldgPlnchkRevChklst
.Carlsbad Fire Department 012371
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category
Date of Report 07/24/2001
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by
Name
Address
Good & Roberts, Inc
2320 Cousteau Ct
City, State Vista CA 92083
Plan Checker
Job Name Quorex •
Job# 012371
Job Address 2075 Corte Del Nogal
Bldg# CB012371
Ste or Bldg No J_
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
D Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
D Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FDJob#
1st 2nd 3rd
012371 FDFile#
Other Agency ID
Carlsbad Fire Department _ 012371
'1635 Faraday Ave Fjre Prevention
Carlsbad, CA 92008 (760) 602-4660
Plan Review
Date of Report 07/24/2001 _ Reviewed by
Name Good & Roberts, Inc
Address 2320 Cousteau Ct
City, State Vista CA 92083
Plan Checker °12371
Job Name juorex
Job Address 2075 Corte Del Nogal Ste or Bldg No
Fire sprinklers may be required in areas 4ft or larger per NFPA 13
STRUCTURAL DETAILS
and
STRUCTURAL CALCULATIONS
for1
QUOREX - SUITE J
ROOF UNITS
at
2015CorteDel Nogal
Carlsbad, CA
Prepared for
Good & Roberts
2320 Cousteau Court
Vista, CA 92083-8346
Prepared by
DEVINE ENGINEERING
12316 Oak Knoll Road, Suite C
Poway, CA 92064
858-748-6168
July 5, 2001
Project #181 01
DEVINE ENGINEERING
11884 Sprmgside Rd
San Diego, CA 92128
(858) 748-6168
joBJS?Uc2S.e.:< £Q1T£ ^A
V
JL&LPI _
SHEET NO .OF_
CALCULATED BV_
CHECKED BY
SCALE
DATE.
DATE.
O~) - £> S - O
'/<?"
n. Q
o -\
\ t>
I 1
II O
JOB.Q\
DEVINE ENGINEERING
11884 Spnngside Rd
San Diego, CA 92128
(858) 748-6168
RHFFT MO **•
r.f.\ r.i ii ATFD RV rTVv/O
rwFrKFn RY
snAi F
OF
DATE O~l - OS -0\
DATF
4x
V x Q-4
n q f-k
3.0 K
1~IOO
SL
<
•4 X V^j-UJOy-U
UK! IT
UKllT
WP - I
UP- a Si
O
O
W = .07 x 4 -& - 48<
\1
t
' > / _f / /
UK! ITS \N'\^U
AR.OUMO UM>T
x_ su* TE. >
DEVINE ENGINEERING
11884 Sprmgside Rd
San Diego, CA 92128(858) 748-6168
SHEET NO
CALCULATED BY_
CHECKED BY
SCALE
OF_
DATE.
DATE.
TO TO
* 83
3' S
- .1*5 xCe-.S - 'lO
4 - .4*4
.k by
DEVINE ENGINEERING
11884 Sprmgside Rd
San Diego, CA 92128(858) 748-6168
JOB.
SHEET NO .
CALCULATED BY_
CHECKED BY
SCALE
Ql
OF
DATE
DATE
- \1 -0\
FACTORY CUP>e> w
AT GA04
EXIST. ROOF
. O
-4 x C. TO AUQhJ \VlTl-( Et^Qt OF
^ FACTORS cupe>
<2 -24" o.o.
\.
*2 UK.MTS
5 KJTO
fo'-o"
"THAM UM\T
55 O
6AC\4
-4. -4-x & •soffoft.TS1 SHALL,
5. HAKQtR^ SHALL Bfc 1CJ=O APPROVED
6, LAG, eouT^ SHALL, ee
A:
WinnitrTTn* i/C Mo Chimtri WK 1 IDvMaHl
DEVINE ENGINEERING
11884 Springside Rd
San Diego, CA92128
(858) 748-6168
SHEET NO OF
CALCULATED BY_
CHECKED BY
SCALE
HATE:
DATE
C? ^-ov o.o.
onnnirrr-xix i /C nob Qhootci WK.I f
Quorex Pharmaceuticals, Inc.
TECHNICAL REPORT
HAZARDOUS MATERIALS SUMMARY
For
2075 Corte del Nogal, Suite J
Carlsbad, CA 92009
July 11, 2001
OCCUPATIONAL
SERVICES, INC
Quorex Pharmaceuticals, Inc July 11, 2001
Technical Report / Hazardous Materials Summary Page 1
Quorex Pharmaceuticals, Inc will occupy 2075 Corte del Nogal, J, Carlsbad, CA 92009 This is a
research and development facility performing bench scale science using typical laboratory quantities of
hazardous materials Based upon the proposed volume and usage of hazardous materials, the proper
occupancy classification for 2075 Corte del Nogal, Suites J, is "B" 2075 Corte del Nogal has one, 1-
hour rated control area
For detailed information concerning both the physical and health hazards at 2075 Corte del Nogal, Suite
J, please refer to the enclosed two chemical classification reports based on 1997 UBC Tables 3D and
3E
The building is equipped with an approved automatic sprinkler system None of the hazardous materials
exceed the exempt amounts for physical or health hazards for storage or use
CONTROLS
The following controls are installed at 2075 Corte del Nogal, Suite J, Carlsbad, CA
1 Automatic Fire Extinguishing Systems
[1997 UFC 1003 2 2]
The building will be equipped with an approved automatic fire extinguishing system
2 Shelving and Lips/Guards
[1997 UBC 307 1 3 (3) and 1997 UFC 8001 11 9]
The laboratories will be equipped with adequately braced and anchored shelving of substantial
noncombustible construction with a chemical resistant coating Shelves will be provided with a
lip or guards Shelf storage of hazardous materials will be maintained in an orderly manner
3 Seismic Bracing
Shelves greater than six feet high will be braced
4 Separation of Incompatible Materials
[1997 UFC 8001 11 8]
Incompatible materials will be separated from each other on shelving, in storage cabinets, and in
waste collection containers Incompatible materials will be separated by one or more of the
following methods
Storage in separate storage cabinets
Separation by a distance of more than twenty feet
Isolation using noncombustible partitions greater than 18" high
Chemists and biologists will receive chemical safety instruction on the separation of incompatible
materials Furthermore, scientists will be trained not to exhaust mcompatibles into the ventilation
systems
5 Empty Containers
[1997 UFC 7902 5 3]
The storage of empty containers and containers previously used for the storage of flammable or
combustible liquids, unless free from explosive vapors, will be stored as required for filled
containers and tanks Tank and containers, when emptied will have the covers or plugs
immediately replaced in openings
Quorex Pharmaceuticals, Inc
Technical Report / Hazardous Materials Summary
My 11,2001
Page 2
Security
[1997 UFC 8001 11 2]
The suite will be equipped with lock(s) to prevent unauthorized entry
Fire Extinguishers
/7997 UFC 7902 5121]
The facility will be equipped with portable dry chemical fire extinguishers
Flammable Liquid and Hazardous Materials Storage Cabinets
[1997 UFC 7901 421 & [1997 UFC 8001 10 6]
Flammable and combustible liquids will be stored in approved flammable liquid storage cabinets
Doors will be well fitted, self-closing, and equipped with a latch The flammable liquid cabinets
will meet the construction standards in 7997 UFC 7901 421
Hazardous materials including Highly Toxic Solids and Liquids, Oxidizer, Reactive, and Water
Reactive materials will be stored in hazardous materials storage cabinets Doors will be well
fitted, self-closing, and equipped with a latch The hazardous materials storage cabinets will
meet the construction standards in 7997 UFC 8001 10 6
Laboratory Fume Hoods and Building Ventilation
a Flammable Gases and Vapors in the Exhaust Systems
The storage and use of flammable and combustible liquids and gases in hoods and exhaust
ducts will be limited to the smallest amounts needed each day Concentrations of gases and
vapors will be diluted to less than 10% of the lower explosive limit (L E L ) for each compound
Therefore, no automatic fire protection systems will be required in the fume hoods or exhaust
ducts
Mechanical exhaust will be provided where Class I, II, or III-A liquids are used (in any amount) in
Groups B, F, M, and S occupancies, or portions thereof The rate of exchange will exceed the
minimum of six air changes per hour
Under normal operating conditions explosive vapor-air mixtures will not develop at QUOREX
PHARMACEUTICALS The majority of the work involving Class I, II, or III-A liquids will be
performed in chemical fume hoods, not in the open laboratories The exhaust ventilation will be
sufficient to maintain nonflammable and nonexplosive vapor concentrations throughout the
entire exhaust duct system Quorex's activities will not require elevated temperatures
Table 1 is a listing of the LEL for commonly used flammable liquids and gases
Flammable Liquids and Gases
Acetone
Acetonitnle
Cyclohexane
Ethanol
Ethyl Acetate
Ethyl Ether
Hexane
Hydrogen
Isopropanol
LEL (%)
26
44
1 3
33
22
1 9
1 2
40
25
10%ofLEL(%)*
026
044
0 13
033
022
0 19
0 12
04
025
Quorex Pharmaceuticals, Inc
Technical Report / Hazardous Materials Summary
July 11,2001
Page 3
Flammable Liquids and Gases
Methanol
Pyndme
Tetrahydrofuran
Toluene
LEL (%)
60
1 8
1 8
1 2
10% of LEL(%)*
06
018
018
012
*DuctsDucts conveying flammable vapors at concentrations greater wan 1U7<.
LEL are required to be equipped with automatic fire protection systems
Face Velocities
Face velocities for laboratory fume hoods will not be less than the following
Type
General Use
Use with
Carcinogens
Average Face Velocity
100lfpm
150lfpm
Minimum Face Velocity
70 Ifpm
125lfpm
10 Water Reactive Materials
[1997 UFC 8001 15234]
Materials that react with water or other liquids to produce a hazard will not be stored in the same
room with flammable or combustible liquids
11 Sources of Ignition
[1997 UFC 7901 10]
In locations where flammable vapors could be present, precautions will be taken to prevent
ignition by eliminating or controlling sources of ignition Adequate grounding and bonding will be
provided to prevent the accumulation of static electricity wherever Class I or II liquids are
transferred or dispensed
12 Compressed Gases
[1997 UFC 4904 2]
Compressed gases in service and in storage will be adequately secured to prevent falling or
being knocked over Cylinders, including empty ones, will have their caps in place and valves
tightly closed
If you have any questions regarding the contents of this report, please contact me at (619) 316-4955
Thank you
Prepared for Quorex Pharmaceuticals, Inc by
Occupational Services, Inc
Brad Stanard, Health and Safety Specialist
Quorex Pharmaceuticals Physical Hazard Report Summary
Storage
CLASS
Location LABORATORY
COMBUSTIBLE LIQUID CLASS II
COMBUSTIBLE LIQUID CLASS III-A
COMBUSTIBLE LIQUID CLASS III-B
COMBUSTIBLE FIBER
CRYOGENIC, FLAMMABLE OR OXIDIZING
EXPLOSIVES
FLAMMABLE SOLID
FLAMMABLE, GAS
FLAMMABLE LIQUID CLASS I-A
FLAMMABLE LIQUID CLASS I-B
FLAMMABLE LIQUID CLASS I-C
ORGANIC PEROXIDE, DETONATABI.E
ORGANIC PEROXIDES CLASS I
ORGANIC PEROXIDES CLASS II
ORGANIC PEROXIDES CLASS III
ORGANIC PEROXIDES CLASS IV
ORGANIC PEROXIDES CLASS V
OXIDIZER CLASS 1
OXID1ZER CLASS 2
OXIDIZER CLASS 3
OXIDIZER CLASS 4
OXIDIZER - GAS
OXIDIZER, GASEOUS OR LIQUIFIED
PYROPHORIC
UNSTABLE (REACTIVE) CLASS 1
UNSTABLE (REACTIVE) CLASS 2
UNSTABLE (REACTIVE) CLASS 3
Lbs Gallons
0000
0000
0000
0000
0000
0000
1 123
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
1 123
L588
0291
1 640
0000
0000
0000
0 000
0000
0000
50 153
0 139
0000
0000
0000
0000
0000
0000
0528
0000
0000
0000
0000
0000
0000
1 585
0000
0000
Cu. Ft.
0 000
0000
0000
0000
0 000
0000
0000
0000
0000
0000
0000
0000
0000
0 000
0 000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Closed System
Lbs. Gallons Cu. Ft.
0000
0000
0 000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0 000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0 000
0000
0000
Open System
Lbs. Gallons
0000
0000
0000
0000
0000
o ooo
0000
0 000
0000
0000
0000
0000
0000
0 000
0000
0 000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0 000
0000
0 000
0000
5015
0000
0000
0000
0 000
0000
0 000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Wednesday, July 11,2001 Page 1 of2
Quorex Pharmaceuticals Physical Hazard Report Summary
Storage
CLASS
UNSTABLE (REACTIVE) CLASS 4
RADIOACTIVES
WATER REACTIVE CLASS 1
WATER REACTIVE CLASS 2
WATER REACTIVE CLASS 3
NON HAZARDOUS
Lbs. Gallons
0000
0000
1 101
1 322
0000
4706
0000
0000
1 070
0013
0000
0000
Cu Ft.
0000
0000
0000
0000
0000
1,2000
00
Closed System
Lbs. Gallons Cu Ft
0000
0000
0000
0000
0000
0000
0000
0000
0 000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Open System
Lbs Gallons
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Wednesday, July 11,2001 Page 2 of2
Quorex Pharmaceuticals Health Hazard Report Summary
Location LABORATORY
Storage
CLASS
CORROSIVES
HIGHLY TOXICS
IRRITANTS
SENSITIZERS
OTHER HEALTH HAZARDS
TOXICS
Lbs.
1 333
1 101
50 872
0111
17569
2599
Gallons
7 180
0000
59 754
0000
50 027
1 480
Cu Ft.
0000
0000
0000
0 000
0 000
0000
Closed System
Lbs
0000
0 000
0000
0000
0000
0000
Gallons
0000
0000
0000
0000
0000
0000
Cu. Ft
0000
0 000
0000
0000
0000
0000
Open
Lbs.
0 000
0000
0000
0 000
0000
0000
System
Gallons
0000
0000
0 000
0 000
0000
0000
Wednesday, July 11,2001 Page 1 of 1
Inventory Report for Quorex
Location LABORATORY
Class COMBUSTIBLE LIQUID CLASS II (LIQUIDS)
Cname CAS# Unit Quantity Quantity in Gallons
Acetic Acid, Glacial
Methyl-2,4-Pentanedione
Methyltetrahydroturan-3-one
64-19-7
815-57-6
3188-00-9
L
T
T
Summary for Gallons (3 detail records)
Class COMBUSTIBLE LIQUID CLASS III-A
Cname CAS# Unit
Decyl Aldehyde
Diethy] Pyrocarbonatc
Hydroxytetrahydrofuran
I lydroxytetrahydrofuran
Mcthoxy-3-buten-2-onc
Phenol
Rose Oxide
112-31-2
1609-47-8
453-20-3
453-20-3
4652-27-1
108-95-2
16409-43-1
T
T
T
T
T
L
T
Summary for Gallons (7 detail records)
Class COMBUSTIBLE LIQUID CLASS III-B
Cname CAS# Unit
D1THIOTHEITOL
DMSO
EGTA
FORMAMIDE - DE1ONIZED
Glyccrol
Hcxanoic Acid
27565^1-9
67-68-5
67-42-5
75-12-7
56-81-5
142-62-1
T
L
T
T
L
T
6 1 585
5 0001
5 0001
Sum 1 588
(LIQUIDS)
Quantity Quantity in Gallons
25 0 007
50 0013
5 0001
5 0001
10 0003
1 0264
5 0001
Sum 0291
(LIQUIDS)
Quantity Quantity in Gallons
5 0001
4 1 057
100 0026
100 0026
1 0264
2 0001
Wednesday, Ju ly 11, 2001 Page 1 of 13
Twcen 20 9005-64-5
Summary for Gallons (7 detail records)
Class CORROSIVES (LIQUIDS )
Cname CAS#
Acetic Acid, Glacial
Bulyryl Chloride
Didiloromethane
Hexanoic Acid
Hydrochloric Acid
Hydrogen Peroxide
Isobutyl Chlorotbrmatc
Phenol
Sodium Hydroxide
Tnchloroacetic Acid
Tncthylamine
64-19-7
141-75-3
75-09-2
142-62-1
7647-01-0
7722-84-1
543-27-1
108-95-2
1310-73-2
76-03-9
121-44-8
Summary for Gallons (1 1 detail records)
Class CORROSIVES (SOLID )
Cname CAS#
Crystal Violet
Hexadecyltnmethylammonium Bromide
IM1DAZOLE
Iron-Ill Chloride, Anhydrous
Iron III Chloride, Hexahydrate
Levuhnic Acid
Lithium Chloride
PHENYL-METHYL SULFONYL FLUORIDE
Potassium Hydroxide
Summary for Lbs (9 detail records)
Wednesday, July 11,2001
548-62-9
57-09-0
288-32-4
7705-08-0
7705-08-0
123-76-2
7447-41-8
329-98-6
1310-58-3
L
Unit
L
T
L
T
L
L
T
L
L
L
T
Unit
M
M
M
M
M
M
M
M
M
1
Quantity
6
50
6
2
4
2
25
1
4
4
100
Quantity
25
25
100
100
100
50
100
5
100
0264
Sum 1 640
Quantity in Gallons
1 585
0013
1 585
0001
1 057
0528
0007
0264
1 057
1 057
0 026
Sum 7 180
Quantity HI Lbs.
0 055
0 055
0220
0220
0220
0 110
0220
0011
0220
Sum 1 333
Page 2 of 13
Class FLAMMABLE LIQUID CLASS I-B (LIQUIDS)
Cname
Acetomtnle UV
Alcohol, Reagent
Butyryl Chloride
Ctiloro-2,4-pentanedionc
Ethanol, 200 proof
F.thyl Acetate
Flammable Solvent Waste
Isopropanol
Methanol
Pentanedione
Pyridinc
Tnethylamine
CAS#
75-05-8
64-17-5
141-75-3
1694-29-7
64-17-5
141-78-6
000338-00-0
67-63-0
67-56-1
600-14-6
110-86-1
121-44-8
Summary for Gallons (12 detail records)
Class FLAMMABLE LIQUID CLASS I-C
Cname CAS#
Isobutanol
Isobutyl Chloroformate
78-83-1
543-27-1
Summary for Gallons (2 detail records)
Class FLAMMABLE SOLID (SOLID )
Cname CAS#
Charcoal
Dinitrophenylhydrazine
Summary for Lbs (2 detail records)
7440-44-0
119-26-6
Unit Quantity
I. 20
I. 16
T 50
T 5
L 12
1. 8
G 30
L 4
L 16
T 25
T 100
T 100
(LIQUIDS)
Unit Quantity
T 500
T 25
Unit Quantity
M 500
M 10
Quantity in Gallons
5284
4227
0013
0001
3 170
2 114
30000
1 057
4227
0007
0 026
0026
Sum 50 153
Quantity in Gallons
0132
0007
Sum 0 139
Quantity in Lbs.
1 101
0022
Sum 1 123
Wednesday, July 11,2001 Page 3 of 13
Class HIGHL Y TOXICS (SOLID )
Cname CAS#Unit Quantity Quantity in Lbs
Muscimol
Sodium Azide
Summary for Lbs (2 detail
Class IRRITANTS
Cname
Acelie Acid, Glacial
Acetomtnlc UV
Alcohol, Reagent
Amy] Alcohol
Butyryl Chloride
Chloro-2,4-pentanedionc
Chloroform
Decyl Aldehyde
Dichloromethanc
Diethyl Pyrocarbonate
DITHIOTIIEITOL
DMSO
EDTA
EGTA
Ethanol, 200 proof
Ethidium Bromide
Ethyl Acetate
Flammable Solvent Waste
FORMAMIDE - DE1ONIZED
Glycerol
Hcxanoic Acid
2763-96-4
26628-22-8
records)
(LIQUIDS)
CAS#
64-19-7
75-05-8
64-17-5
75-85-4
141-75-3
1694-29-7
67-66-3
112-31-2
75-09-2
1609-47-8
27565-41-9
67-68-5
6381-92-6
67-42-5
64-17-5
1239-45-8
141-78-6
000338-00-0
75-12-7
56-81-5
142-62-1
1
M
Unit
I.
L
L
T
T
T
L
T
L
T
T
L
T
T
L
T
L
G
T
L
T
1
500
Quantity
6
20
16
500
50
5
4
25
6
50
5
4
500
100
12
500
8
30
100
1
2
0000
1 101
Sum 1 101
Quantity in Gallons
1 585
5284
4227
0 132
0013
0001
1 057
0007
1 585
0013
0001
1 057
0132
0026
3 170
0 132
2 114
30000
0026
0264
0001
Wednesday, July 11,2001 Page 4 of 13
Hydrochloric Acid
Hydroxytetrahydrofuran
Hydroxytetrahydrofuran
Isobutanol
Isopropanol
Methanol
Methoxy-3-buten-2-one
Mcthyl-l,3-Cyclopentanedione
Mcthyl-1 ,3-Cyclopentanedione
Methyl-2,4-Pentancdionc
Mcthyl-2-Cyclopcntcn-l -one
Methyl-2-Cyclopcntcn-l -one
Methyltctrahydrofuran-3-one
Pentanedione
Pyridinc
Rose Oxide
Sodium Hydroxide
Trichloroacctic Acid
Triton X- 100
Twecn 20
Summary for Gallons (41
Class IRRITANTS
Cname
ACES
Acctylcyclopentanone
Adenine
Adonitol
Agar, Skim Milk
Agar, TSA Blood Base
7647-01-0
453-20-3
453-20-3
78-83-1
67-63-0
67-56-1
4652-27-1
765-69-5
765-69-5
815-57-6
1120-73-6
1120-73-6
3 1 88-00-9
600-14-6
110-86-1
16409-43-1
1310-73-2
76-03-9
9002-93-1
9005-64-5
detail records)
(SOLID)
CAS#
7365-82-4
1670-46-8
73-24-5
10058-44-3
1120-73-6
1121-05-7
L
T
T
T
L
L
T
T
T
T
T
T
T
T
T
T
L
L
T
L
Unit
M
M
M
M
M
M
4
5
5
500
4
16
10
5
10
5
5
1
5
25
100
5
4
4
100
1
Quantity
25
5
1
1
500
500
1 057
0001
0001
0 132
1 057
4227
0003
0001
0003
0001
0001
0000
0001
0007
0026
0001
1 057
1 057
0026
0264
Sum
Quantity m Lbs.
0055
0011
0002
0002
1 101
1 101
59 754
Wednesday, July 11,2001 Page 5 of 13
Agarose, General Purpose
Agarose, Low Melting Point
Agarose, Small Fragments
Ammonium Acetate
Ammonium Chloride
Ammonium Sulfate
Ampicillm
Bone Acid
Bromophenol Blue
Broth, I.B Miller
Broth, Phenol Red Base
Calcium Chloride, Dihydratc
Cinoxacm
Coomassie Brilliant Blue R-250
Cystcme Mydrochlonde Monohydrate
Dihydro-2-Methylfuran
Dihydrouracil
Dinitrophenylhydrazmc
Hthyl-2,4-Pentanedione
Ethyl-2-Ilydroxy-2-Cyclopcnten-l-one
Ficoll
Glucose, Anhydrous
GLYCINE
HEPES
Hydantom
Hygromycm B
Iodine
IPTG
IPTG
Iron III Chloride, Anhydrous
Iron III Chloride, Hexahydrate
39346-81-1
39346-81-1
1128-23-0
631-61-8
12125-02-9
7783-20-2
69-52-3
10043-35-3
1 1 5-39-9
130-40-5
13436-46-9
10035-04-8
28657-80-9
6104-59-2
226267-70-9
25564-22-1
504-07-4
119-26-6
3859-41-4
4338-47-0
26873-85-8
488-86-8
56-40-6
7365-45-9
461-72-3
31282-04-9
7553-56-2
367-93-1
367-93-1
7705-08-0
7705-08-0
M
M
M
K
M
K
M
K
M
M
M
M
M
M
M
M
M
M
M
M
M
K.
M
M
M
I
M
M
M
M
M
100
25
100
1
500
1
25
1
5
500
500
500
1
25
25
5
1
10
5
25
10
1
500
100
25
50
30
5
1
100
100
0220
0055
0220
2203
1 101
2203
0055
2203
0011
1 101
1 101
1 101
0002
0055
0055
0011
0002
0022
0011
0055
0022
2203
1 101
0220
0 055
0000
0066
0011
0002
0220
0220
Wednesday, July 11,2001 Page 6 of 13
Kmelin Riboside
Laurie Acid
Lithium Chloride
Lithium Dodccyl Sulfate
Lyso/yme, Egg White
Magnesium Chloride, Hexahydrale
Magnesium Sulfale, Heptahydrate
Manganese Chloride
MES
MOPS
NADPH
Phenol Red
Piperacillm
POLYETHYLENE GLYCOL - (8,000 MW)
Potassium Acetate
Potassium Chloride
Potassium Phosphate, Dibasic
Potassium Phosphate, Monobasic
Potassium Sulfate
Potassium Tetraborate Tetrahydrate
Ribosc
Ribosc
Ribtilosc
Roxithromycm
Sodium Acetate, Anhydrous
Sodium Bisulfite
Sodium Chloride
Sodium Citrate
Sodium Phosphate, Dibasic Anydrous
Sodium Phosphate, Monobasic Monohydratc
Sorbose
4338-47-0
143-07-7
7447-41-8
2044-56-6
12650-88-3
7786-30-3
10034-99-8
13446-34-9
4432-31-9
1132-61-2
765-69-5
143-74-8
59703-84-3
25322-68-3
127-08-2
7447-40-7
7758-11-4
7558-80-7
7778-80-5
12045-78-2
979-92-0
979-92-0
979-92-0
80214-83-1
127-09-3
7631-90-5
7647-14-5
6132-04-3
7758-29-4
7758-29-4
87-79-6
I
M
M
M
M
M
M
M
K
K
1
M
M
K
M
M
M
M
M
M
I
M
1
M
M
M
K
M
M
M
1
100
2
100
25
5
500
500
125
1
1
25
5
1
1
500
500
500
500
500
500
250
10
25
1
500
500
2
100
500
500
100
0000
0004
0220
0055
0011
1 101
1 101
0275
2203
2203
0000
0011
0002
2203
1 101
1 101
1 101
1 101
1 101
1 101
0001
0022
0000
0002
1 101
1 101
4405
0220
1 101
1 101
0000
Wednesday, July 11,2001 Page 7 of 13
Sorbosc
Sulfisoxazole
SULFOSAUCYCLIC ACID
Tetracyclme
Thiamme Hydrochlonde
Tobramycin
Tns
Tns-HCl
Trypan Blue
Tryptophan
Urea
Vancomycin
XYLUNECYANOLPF
Xylilol
Yeast Extract
Zinc Chloride
Zingerone
87-79-6
127-69-5
5965-83-3
60-54-8
67-03-8
32986-56-4
77-86-1
77-86-1
72-57-1
73-22-3
57-13-6
1404-93-9
4463-44-9
87-99-0
8013-01-2
7646-85-7
122-48-5
Summary for Lbs (85 detail records)
Class NON HAZARDOUS (GAS )
Cname CAS#
NITROGEN, COMPRESSliD 7727-37-9
Summary for Cu Ft (1 detail record)
Class NON HAZARDOUS (SOLID )
Cname CAS#
Agar
ALBUMIN
Arabmose
Deuterium Oxide
9002-18-0
9048-46-8
5328-37-0
7789-20-0
M
M
M
M
M
M
K
M
M
M
K
1
M
M
M
M
M
Unit
c
Unit
M
M
M
M
1
25
125
25
100
5
1
500
25
25
1
250
25
5
500
100
5
Sum
Quantity Quantity in
1200
Sum
Quantity Quantity in
500
25
100
5
0002
0055
0275
0055
0220
0011
2203
1 101
0055
0055
2203
0001
0055
0011
1 101
0220
0011
50872
Cu. Ft.
1 ,200 000
1,200000
Lbs
1 101
0055
0220
0011
Wednesday, July 11,2001 Page8ofl3
Enoxacm
Fructose
Gelatin, Nutrient
Ilomoserme
Jasmone
Sodium Bicarbonate
Sucrose
Summary for l.bs (1 1 detail records)
Class OXIDIZER CLASS
Cname
84294-96-2
57-48-7
488-10-8
672-15-1
672-15-1
144-55-8
57-50-1
1
M
M
1
M
M
M
/ (LIQUIDS)
CAS# Unit
Hydrogen Peroxide 7722-84-1
Summary for Gallons ( 1 detail record)
Class OTHER HEALTH HAZARDS
Cname CAS#
Acetic Acid, Glacial
Alcohol, Reagent
Chloroform
Dichloromcthane
DMSO
IIDJA
Clhanol, 200 proof
Ethldium Bromide
Flammable Solvent Waste
I-ORMAMIDH - DEIONIZED
Glyccrol
Hexanoic Acid
Hydrochloric Acid
Isobutanol
64-19-7
64-17-5
67-66-3
75-09-2
67-68-5
6381-92-6
64-17-5
1239-45-8
000338-00-0
75-12-7
56-81-5
142-62-1
7647-01-0
78-83-1
500
1
500
250
5
500
500
Sum
Quantity Quantity
L 2
Sum
(LIQUIDS)
Unit Quantity Quantity
L 6
L
L
L
L
T
L
T
G
T
L
T
L
T
16
4
6
4
500
12
500
30
100
1
2
4
500
0001
0002
1 101
0001
0011
1 101
1 101
4706
in Gallons
0528
0528
in Gallons
1 585
4227
1 057
1 585
1 057
0 132
3 170
0 132
30000
0026
0264
0001
1 057
0132
Wednesday, July 11,2001 Page 9 of 13
Isopropanol
Methanol
Phenol
Tncthylamme
Triton X-100
67-63-0
67-56-1
108-95-2
121-44-8
9002-93-1
I.
L
L
T
T
4
16
1
100
100
1 057
4227
0264
0026
0026
Summary for Gallons (19 detail records)
Sum
Class OTHER HEALTH HAZARDS (SOLID )
Cname
Ammonium Chloride
CAS#
12125-02-9
Unit Quantity Quantity in Lbs.
M 500
Lithium Chloride 7447-41-8 M 100
1 101
Ammonium Sulfatc
Ampicillm
Biotm
Broth, LB Miller
Chloramphcmcol
Crystal Violet
lirythromycin
Glutathione
Iodine
IPTG
1PTG
Kanamycin Sulfale
7783-20-2
69-52-3
58-85-5
130-40-5
56-75-7
548-62-9
114-07-8
70-18-8
7553-56-2
367-93-1
367-93-1
25389-94-0
K
M
1
M
M
M
M
M
M
M
M
M
1
25
500
500
100
25
50
10
30
5
1
10
2203
0055
0001
1 101
0220
0055
0 110
0022
0066
0011
0002
0022
0220
Magnesium Sulfatc, Heptahydrate
Manganese Chloride
MOPS
Muscimol
Nitnlotnacetic Acid
Phenol-Red Broth Base
PHENYL-METHYL SULFONYL FLUORIDE
10034-99-8
13446-34-9
1132-61-2
2763-96-4
139-13-9
83-88-5
329-98-6
M
M
K
I
M
M
M
500
125
1
1
100
500
5
1 101
0275
2203
0000
0220
1 101
0011
50 027
Wednesday, July 11,2001 Page 10ofl3
Potassium Tctraborate Tetrahydrale
Ribollavin
Sodium Bisulfite
Streptomycin Sulfate
SULFOSALICYCLIC ACID
Tetracyclmc
Tobramycin
Tns
Trypan Blue
Urea
Zinc Chloride
12045-78-2
83-88-5
7631-90-5
3810-74-0
5965-83-3
60-54-8
32986-56-4
77-86-1
72-57-1
57-13-6
7646-85-7
M
M
M
M
M
M
M
K
M
K
M
500
10
500
100
125
25
5
1
25
1
100
1 101
0022
1 101
0220
0275
0055
0011
2203
0055
2203
0220
Summary for Lbs (32 detail records)
Sum 17569
Class UNSTABLE (REACTIVE) CLASS 1 (LIQUIDS)
Cname CAS#
Acetic Acid, Glacial 64-19-7
Unit Quantity Quantity in Gallons
L 6 1 585
Summary for Gallons (1 detail record)
Sum 1 585
Class UNSTABLE (REACTIVE) CLASS 3 (SOLID)
Cname CAS#Unit Quantity Quantity in Lbs.
Dinitrophenylliydrazme
Sodium Azidc
119-26-6
26628-22-8
M
M
10 0022
500 1 101
Summary for Lbs (2 detail records)
Class SENSITIZERS (SOLID)
Cname CAS#
Lithium Dodecyl Sulfatc 2044-56-6
Tnmethoprim 738-70-5
Vancomycm 1404-93-9
Sum
Unit Quantity Quantity in Lbs
~M 25 0055
M 25 0 055
i "250 ~b"oo!
1 123
Wednesday, July 11,2001 Page 11 of 13
Summary for Lbs (3 detail records)
Sum 0111
Class TOXICS (LIQUIDS)
Cname CAS#Unit Quantity Quantity in Gallons
Ethidium Bromide
Phenol
Trichloroacetie Aeid
Tnethylamine
Summary for Gallons (4 detail records)
Class TOXICS (SOLID )
Cname
Bromophenol Blue
Chloramphemcol
Crystal Violet
Hexadecyltnmethylanimonium Bromide
1MIDAZOLE
Lithium Chloride
Potassium Hydroxide
Sodium Bisulfite
Streptomycin Sull'ate
Jnmethoprim
"Zinc Chloride
» Summary for Lbs (11 detail records)
Class. WATER REACTIVE
Cname
Dicthyl Pyrocarbonatc
Sodium Hydroxide
1239-45-8
108-95-2
76-03-9
121-44-8
CAS#
115-39-9
56-75-7
548-62-9
57-09-0
288-32-4
7447-41-8
1310-58-3
7631-90-5
3810-74-0
738-70-5
7646-85-7
CLASS
CAS#
1609-47-8
1310-73-2
T
L
L
T
Unit
M
M
M
M
M
M
M
M
M
M
M
500
1
4
100
Quantity
5
100
25
25
100
100
100
500
100
25
100
1 (LIQUIDS)
Unit Quantity
T
L
50
4
0 132
0264
1057
0026
Sum 1 480
Quantity in Lbs.
0011
0220
0055
0055
0220
0220
0220
1 101
0220
0055
0220
Sum 2 599
Quantity in Gallons
0013
1 057
Wednesday, July 11,2001 Page 12 of 13
Summary for Gallons (2 detail records)
Sum
Class WA TER REA CTIVE CLASS 1 (SOLID )
Cname CAS# Unit Quantity Quantity in Lbs
127-08-2 MPotassium Acetate 500 1 101
Summary tor Lbs (1 detail record)
Sum
Class WA TER REA CTIVE CLASS 2 (LIQUIDS)
Cname CAS# Unit Quantity Quantity in Gallons
TButyryl Chloride 141-75-3 50 0013
Summary tor Gallons (I detail record)
Sum
Class WA TER REA CTIVE CLASS 2 (SOLID )
Cname CAS# Unit Quantity Quantity in Lbs.
1310-58-3
26628-22-8
1 070
1 101
0013
Potassium Hydroxide M 100
Sodium Azide M 500
0220
iloT
Summary for Lbs (2 detail records)
Sum I 322
Wednesday, July 11,2001 Page 13 of 13