Loading...
HomeMy WebLinkAbout2075 CORTE DEL NOGAL; J; CB012371; Permit08-16-2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB012371 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 08/16/2001 Applicant GOOD & ROBERTS INC 1090 JOSHUA WAY VISTA, CA 92083 619-598-7614 2075 CORTE DEL NOGAL CBAD St J Tl Sub Type INDUST 2130610700 Lot# 0 Status $40,00000 Construction Type NEW Applied Reference # Entered By QUAREX PHARMICEUTICALS-ADD 3 FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPMENTIssued Inspect Area ISSUED 07/12/2001 RMA Plan Approved 08/16/2001 Owner SAN-GAL TRUST 550 WCST #1820 SAN DIEGO CA 92101 7492 08/1.6/01 0002 OJ 02 CGP 382-99 Total Fees $577 07 Total Payments To Date $194 08 Balance Due $382 99 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $298 59 Meter Size $0 00 Add'l Reel Water Con Fee $19408 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $8 40 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $3500 $41 00 $000 $000 $000 $000 $577 07 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 1 PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO fffi/O \ EST VAL ty " Plan Ck Deposit Validated By Date "7 iisjiAddress (include Bldg/Suite #)Business Name (at thisladdress) Legal Description Assessor s Description Parcel # of Work X f Lot No Subdivision Name/Number Unit No Phase No Total # of units 4490 07/12/01 MO:> ni art Existing Use £/t>tfrj SO.FT / Proposed Use #of Stones / # of yfiedrooms CGP / /) #of 194 Bathrooms .08 ^,A/X) 3 ffae fttofis A^ teumzo 2 CONTACT PERSON (if different from applicant) Name 3 ...... APPLICANT,;;;ntractor Address . Agent for Contractor JLOU.S~Tf. fr ~^ Lj Owner'"'' fj 'Agent for CltV for Owner •:: i rr ' State/Zip Telephone # Fax # Name 4 PROPERTY OWNER Address City State/Zip Telephone # Address City State/Zip Telephone ffName 5! CONTRACTOR -COMPANY NAME : 1 "" '.. ..." if" -'. Jv:- • -''I ,'••'"V ' '!P\ ' ''3 "X,, -s •-"•: (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars |$500W r^r^rO ^ Arrterrt OT^^ ^J^> C^^reAJ <?JT OJSTrt S^S^C,/* Name Stato License # Address License Class 6 City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # 6 WORKERS71 COMPENSATION T ; ; , Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations [~1 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued ^Bl I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company .3 iffT^- F(J/\JJ Policy No ^j? 3 "^-3 XS"" O& Expiration Date ^ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000) in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney s fees SIGNATURE (^j£j£^£ DATE ? - fL-~O/ 7 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor s License Law for the following reason l~l I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) PI I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement (~l YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY ,; ,:% V; _ % . ;J Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? fj] YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES l~l NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8. > CONSTRUCTION LENDING AGENCY # , :,., I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME LENDER'S ADDRESS 9 r:S: APPLICANT CERTIFICATION - '" '"' •, '•• '" - :: •-.. ::-.. 3;: \"',; .. J -'" I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a periorJof 1^0 days (Section 106 4 4 Uniform Building Code) APPLICANT'S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept- Building Engineering Planning CMWD St Lite cFire Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected^ By C Inspected Bv Inspected Bv Comments <; CB012371 QUAREX PHARMICEUTICALS-ADD 3 FUME HOODS,LIGHTS, ROOF MOUNTED A/C 2075 CORTE DEL NOGAL #J CHUCK CA ' /£- '.JJLJ-tdis 3T ^ Phone 7605987614 Water Dist CA Date % /?7/niInspected ' ^' Date Inspected Date Inspected - fi ^ f Date Permit Type Sub Type EQUIPM Lot 0 \ L- Approved Approved Approved f $/?/- I 08/17/2001 Tl INDUS! Disapproved Disapproved Disapproved City of Carlsbad Final Building Inspection Dept: Building Engineering Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspectedxo Inspected Bv Inspected Bv Comments Planning CMWD St Lite QFire Date CB012371 Permit Type QUAREX PHARMICEUTICALS-ADD 3 Sub Type FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPM 2075 CORTE DEL NOGAL #J CHUCK CA <C^z£^ rr t* Phone 7605987614 Water Dist CA Date tf/-?/ Inspected "/(flD Date Inspected Date Inspected '•***£> fs?»*n/. Lot 0 f Approved Approved Approved \£J *f/?/M 08/17/2001 Tl INDUST .--- Disapproved Disapproved Disapproved City of Carlsbad Bldg Inspection Request For 09/11/2001 PermiW CB012371 Title QUAREX PHARMICEUTICALS-ADD 3 Description FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPMENT Inspector Assignment TP 2075 CORTE DEL NOGAL J Lot 0 Type Tl Job Address Suite Location APPLICANT GOOD & ROBERTS INC Owner PLETA TRUST Remarks Sub Type INDUST Phone 6197193630 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By J P JONES Entered By CHRISTINE Act Comments A? Associated PCRs Inspection History Date Description Act Insp Comments 08/17/2001 89 Final Combo CO TP City of Carlsbad Bldg Inspection Request For 08/17/2001 Inspector AssignmentPermit# CB012371 Title QUAREX PHARMICEUTICALS-ADD 3 Description FUME HOODS, LIGHTS, ROOF MOUNTED A/C EQUIPMENT 2075 CORTE DEL NOGAL J Lot 0 Type Tl Job Address Suite Location APPLICANT GOOD & ROBERTS INC Owner PLETA TRUST Remarks Sub Type INDUST Phone 7605987614 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments Requested By CHUCK Entered By CHRISTINE Associated PCRs Inspection History Date Description Act Insp Comments CITY OF CARLSBAD BUILDING DEPARTMENT DATE &/'?/*/ NOTICE LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE TIME '/ 3 FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? i ! YES FOR FURTHER INFORMATION, CONTACT -&C>Jt ' BUILDING INSPECTOR CODE ENFORCEMENT OFFICER "NOTICECITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE A?'//If TIME LOCATION PERMIT NO \ FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? ! _ i YES FOR FURTHER INFORMATION, CONTACT £&£ "Z PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER EsGil Corporation In Partnership witfi. government for 'Bu.iUmg Safety DATE August 16, 2001 JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 01-2371 SET III PROJECT ADDRESS 2075 Corte Del Nogal PROJECT NAME QUOREX PHARMACEUTICALS The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed/ Person contacted Chuck Glynn Telephone # Date contacted 8/16/01 (by Abe) Fax # Mad Telephone Fax In Person XX REMARKS Applicant to carry approved set of plans to the cityyOW by Mike P APPLICANT WILL SLIP SHEET THE FOLLOWING SHEETS INTO THE C/TY PLAN SET. SHEETS A.1, E1.1, E1.2, E2.1, E3.1, M3.1 andM4.1. Building Official to review the Fire Department approval of the Revised Technical Report Hazardous jylaterials Summary dated August 1, 2001. By Abe Doliente Enclosures Esgil Corporation D GA D MB D EJ D PC 8/16/01 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858) 560-1468 4 Fax (858) 560-1576 EsGil Corporation In fartnersfiip wit ft Government for Quitting Safety DATE August 14, 2001 JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 01-2371 SET II PROJECT ADDRESS 2075 Corte Del Nogal PROJECT NAME QUOREX PHARMACEUTICALS The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck 1X1 The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Good & Roberts Inc 2320 Coosteau Ct, Vista, CA 92083 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted ChuckGlynn— Telephone* 760/598-7614 Date contacted ^M (by 73) Fax # ILoO- ^S^fe Mail Telephone -"Tax — In Person REMARKS By Abe Doliente Enclosures Esgil Corporation 13 GA D MB D EJ D PC 8/6/01 tmsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 Carlsbad 01-2371 II August 14, 2O01 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO 01-2371 PROJECT ADDRESS 2075 Corte Del Nogal SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 8/6/01 August 14, 2001 REVIEWED BY Abe Doliente FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new sets of prints to Esgil Corp ortothebldg dept of the juris B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? Q Yes a No F Carlsbad 01-2371 II August 14, 2001 1 All sheets of the plans including the SX sheets of the calculations shall be signed and sealed/stamped by the Engineer Please include the license expiration date and the date the plans are signed 3 Please see the following corrections for electrical, plumbing and mechanical * PLUMBING, MECHANICAL AND ENERGY CORRECTIONS 4 PLAN REVIEWER: Glen Adamek I Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code Sheet T1 is not signed? And sheet A1 is missing from the new plan package. 3 Building Official to review the Fire Department approval of the Revised Technical Report Hazardous Materials Summary dated August 1. 2001 MECHANICAL (1997 UNIFORM MECHANICAL CODE) 8 Correct the exhaust discharge clearances from exhaust fan EF-5 to show the required minimum 3 feet from the exterior wall (parapet wall or screen wall) and 3 feet from the roof, as per UMC, Section 505.9. ENERGY CONSERVATION 10 The plans show an existing non-conditioned space now being conditioned Provide the required envelope energy design calculations for this change in envelope The response states the existing space is existing conditioned space, but the plans do not show any existing HVAC equipment serving the Research Area. Nothing shows existing HVAC being removed. Please correct. I1 On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design See item #10 above. 12 The existing restroom opening into the newly conditioned space is also newly conditioned space See item #10 above. A) The new conditioned floor area is about 740 square feet Not the 665 square feet used B) Please correct the lighting design to include the existing restroom now being conditioned F ™Carlsbad O1-2371 II August 14, 2001 13 Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131(d) (5,000 square foot exemption has been eliminated-AB 970 energy design change) 14 The corrected, completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans 15 The Documentation Author and the Principal Envelope Designer must sign the corrected ENV-1 form 16 The Documentation Author and the Principal Lighting Designer must sign the corrected LTG-1 form 17 The Documentation Author and the Principal Mechanical Designer must sign the corrected MECH-1 form 18 Complete energy plan check will be done when complete corrected energy designs are provided Note: If you have any questions regarding this plumbing, mechanical and energy plan review list please contact Glen Adamek at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans EsGil Corporation In Partnership with government for "Building Safety DATE July 27, 2001 Q APPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 01-2371 SET I PROJECT ADDRESS 2O75 Corte Del Nogal PROJECT NAME QUOREX PHARMACEUTICALS The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X] The applicant's copy of the check list has been sent to Good & Roberts Inc 2320 Coosteau Ct Vista, CA 92083 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Chuck Glynn (V.M.) Telephone # 760/598-7614 ft.-H-*>^e>/Date contacted ~?- z.*7-<" (by £**. ) Fax # Telephone ^ Fax In Person XI REMARKS T I includes addition of 3 hood fumes and related mechanical equipment with roof mounted equipment By Abe Doliente Enclosures Esgil Corporation [3 GA S MB D EJ D PC 7/16/01 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 Carlsbad 01-2371 July 27, 20O1 GENERAL PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO O1-2371 PROJECT ADDRESS 2075 Corte Del Nogal DATE PLAN RECEIVED BY DATE REVIEW COMPLETED ESGIL CORPORATION 7/16/01 July 27, 2001 REVIEWED BY Abe Doliente FOREWORD (PLEASE READ)- This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law • Please make all corrections on the original tracings and submit two new complete sets of prints to Esgil Corp ortothebldg dept of the juris • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? Q Yes Q No Carlsbad O1-2371 July 27, 2001 1 All sheets of the plans including the SX sheets of the calculations shall be signed and sealed/stamped by the Engineer Please include the license expiration date and the date the plans are signed 2 Sheet 3 of the calculations calls for 4 X 16 purlins, but the sketches show 4X14 Please clarify 3 Please see the following corrections for electrical, plumbing and mechanical The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Abe Doliente at Esgil Corporation Thank you * ELECTRICAL PLAN REVIEW * 1996 NEC * PLAN REVIEWER: MORTEZA BEHESHTI 1 Show or note on the plans the method used to limit fault currents to 10,000 amps on new branch circuits 2 Show exit signs on the lighting plan(s) at all required exits and specify them as being self- luminous or having a second source of power (battery or generator) This is required when two exits are required per the UBC UBC 1003 2 8 2 and NEC 700-16 3 In all occupancies where the exit system serves 100 or more occupants, provide a minimum of 1 foot-candle of emergency illumination at the floor level and specify a second source of power for the emergency illumination (battery or generator) UBC 1003 2 9 2 & NEC 700- 16 Note: If you have any questions regarding this electrical plan review list please contact Morteza Beheshti at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans * PLUMBING, MECHANICAL AND ENERGY CORRECTIONS * PLAN REVIEWER: Glen Adamek 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 The Technical Report Hazardous Materials Summary shows many of the materials are only stored and not used? Why are the materials stored and not used? Carlsbad 01-2371 July 27, 2O01 3 Building Official to review the Fire Department approval of the Technical Report Hazardous Materials Summary 4 Specify the date of the building permit date of submittal for this project If after June 1, 2001, energy design based upon the AB970 revisions will be necessary See "Energy" below PLUMBING (1997 UNIFORM PLUMBING CODE) 5 Correct the plumbing plan sheet P2 1 to clearly show what is part of this permit and what is "Under a Separate Permit'"? If sinks are not apart of this permit, then correct the air conditioning unit condensate waste line to an approved existing fixture MECHANICAL (1997 UNIFORM MECHANICAL CODE) 6 Clearly not on the plans the Class I, II, or III-A liquids are used only within operating fume hoods as per the Technical Report Hazardous Materials Summary UBC, Section 120222 7 Show the location of the required roof access ladder to roof mounted HVAC equipment UMC, Section 307 5 8 Detail exhaust ventilation system (fume hood systems) compliance with UMC Chapters 5 &6 a) Detail the exhaust outlet clearances as per UMC, Sections 504 6 & 505 9 b) Clearly show the type of material to be exhausted by each exhaust system c) Separate and distinct systems shall be provided for incompatible materials UMC, Section 505 2 The plans show only one exhaust system As per the Technical Report Hazardous Materials Summary and UMC, Section 505.2, more than one exhaust system is required. d) Clearly show the duct materials are suitable for the intended use UMC, Section 6091 e) Clearly show the exhaust duct material and gage used for each duct size See UMC, Table 5-B & 5-C f) Detail minimum duct conveying velocities as per UMC, Section 505 4 and Table 5- A g) Detail required duct cleanouts as per UMC, Section 609 4 h) Detail duct support as per UMC, Section 609 6 i) Detail protection from physical damage as per UMC, Section 609 9 9 Ventilation air supply shall be sufficient to provide make-up air for exhaust systems when required by this code or the Building Code Make-up air systems shall be electrically interlocked with their associated exhaust systems UMC, Section 402 4 Heat Pump HP-4 and fans EF-5 and SF-1 must all be electrically interlocked. Carlsbad 01-2371 July 27, 2001 ENERGY CONSERVATION 10 The plans show an existing non-conditioned space now being conditioned Provide the required envelope energy design calculations for this change in envelope 11 On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design 12 The existing restroom opening into the newly conditioned space is also newly conditioned space a) The new conditioned floor area is about 740 square feet Not the 665 square feet used b) Please correct the lighting design to include the existing restroom now being conditioned 13 Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131 (d) 14 The corrected, completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans 15 The Documentation Author and the Principal Envelope Designer must sign the corrected ENV-1 form 16 The Documentation Author and the Principal Lighting Designer must sign the corrected LTG-1 form 17 The Documentation Author and the Principal Mechanical Designer must sign the corrected MECH-1 form 18 Complete energy plan check will be done when complete corrected energy designs are provided Note: If you have any questions regarding this plumbing, mechanical and energy plan review list please contact Glen Adamek at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans Carlsbad 01-2371 July 27, 2001 JURISDICTION Carlsbad VALUATION AND PLAN CHECK FEE PLAN CHECK NO 01-2371 PREPARED BY Abe Doliente DATE July 27, 2001 BUILDING ADDRESS 2075 Corte Del Nogal BUILDING OCCUPANCY B TYPE OF CONSTRUCTION V-N BUILDING PORTION T 1 (see below) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Valuation Multiplier By Ordinance Reg Mod VALUE ($) 40,000 40,000 Bldg Permit Fee by Ordinance jr Plan Check Fee by Ordinance V Type of Review [J Repetitive Fee -, Repeats E Complete Review D Other n Hourly D Structural Only Hour* Esgil Plan Review Fee $298 59] $194 08 $167.21 Comments Add 3 fume hoods and related mechanical equipment with roof mounted equipment Sheet! of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE ADDRESS 5 CLA RESIDENTIAL RESIDENTIAL ADDITION MINOR (< $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEE DATE Docs/Mlsforms/Planmng Engineering Approvals n n PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check Planner APN Address Phone (760) 602- U/ 9- Type of Project & Use Zoning General Plan Net Project Density _ Facilities Management Zone DU/AC CFD fin/nut» # Circle One Date of participation Remaining net dev acres (For non-residential development Type of land used created by this permit ) Legend X Item Complete Environmental Review Required1 DATE OF COMPLETION YES Item Incomplete - Needs your action NO TYPE Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required: APPROVAL/RESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES CA Coastal Commission Authority? YES NO_ NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # YES NO Foliow-Up Actions- 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed H \ADMIN\COUNTER\BldgPlnchkRevChklst I I Inclusionary Housing Fee required. YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') Site Plan. 1 Provide a fully dimensional site plan drawn to scale Show. North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) LJ \_j \_\ 2 Provide legal description of property and assessor's parcel number D Zoning- I 1 Setbacks Front Interior Side Street Side Rear Top of slope- ill] \_\ 2 Accessory structure s« Front Interior Side Street Side Rear Structure separation: 3 Lot Coverage O 4 Height Til n 5 Parking. Spaces Required Required Required Required Required Jtbacks Required Required Required Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \ADMIN\COUNTER\BldgPlnchkRevChklst .Carlsbad Fire Department 012371 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category Date of Report 07/24/2001 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Good & Roberts, Inc 2320 Cousteau Ct City, State Vista CA 92083 Plan Checker Job Name Quorex • Job# 012371 Job Address 2075 Corte Del Nogal Bldg# CB012371 Ste or Bldg No J_ Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards D Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 2nd 3rd 012371 FDFile# Other Agency ID Carlsbad Fire Department _ 012371 '1635 Faraday Ave Fjre Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report 07/24/2001 _ Reviewed by Name Good & Roberts, Inc Address 2320 Cousteau Ct City, State Vista CA 92083 Plan Checker °12371 Job Name juorex Job Address 2075 Corte Del Nogal Ste or Bldg No Fire sprinklers may be required in areas 4ft or larger per NFPA 13 STRUCTURAL DETAILS and STRUCTURAL CALCULATIONS for1 QUOREX - SUITE J ROOF UNITS at 2015CorteDel Nogal Carlsbad, CA Prepared for Good & Roberts 2320 Cousteau Court Vista, CA 92083-8346 Prepared by DEVINE ENGINEERING 12316 Oak Knoll Road, Suite C Poway, CA 92064 858-748-6168 July 5, 2001 Project #181 01 DEVINE ENGINEERING 11884 Sprmgside Rd San Diego, CA 92128 (858) 748-6168 joBJS?Uc2S.e.:< £Q1T£ ^A V JL&LPI _ SHEET NO .OF_ CALCULATED BV_ CHECKED BY SCALE DATE. DATE. O~) - £> S - O '/<?" n. Q o -\ \ t> I 1 II O JOB.Q\ DEVINE ENGINEERING 11884 Spnngside Rd San Diego, CA 92128 (858) 748-6168 RHFFT MO **• r.f.\ r.i ii ATFD RV rTVv/O rwFrKFn RY snAi F OF DATE O~l - OS -0\ DATF 4x V x Q-4 n q f-k 3.0 K 1~IOO SL < •4 X V^j-UJOy-U UK! IT UKllT WP - I UP- a Si O O W = .07 x 4 -& - 48< \1 t ' > / _f / / UK! ITS \N'\^U AR.OUMO UM>T x_ su* TE. > DEVINE ENGINEERING 11884 Sprmgside Rd San Diego, CA 92128(858) 748-6168 SHEET NO CALCULATED BY_ CHECKED BY SCALE OF_ DATE. DATE. TO TO * 83 3' S - .1*5 xCe-.S - 'lO 4 - .4*4 .k by DEVINE ENGINEERING 11884 Sprmgside Rd San Diego, CA 92128(858) 748-6168 JOB. SHEET NO . CALCULATED BY_ CHECKED BY SCALE Ql OF DATE DATE - \1 -0\ FACTORY CUP>e> w AT GA04 EXIST. ROOF . O -4 x C. TO AUQhJ \VlTl-( Et^Qt OF ^ FACTORS cupe> <2 -24" o.o. \. *2 UK.MTS 5 KJTO fo'-o" "THAM UM\T 55 O 6AC\4 -4. -4-x & •soffoft.TS1 SHALL, 5. HAKQtR^ SHALL Bfc 1CJ=O APPROVED 6, LAG, eouT^ SHALL, ee A: WinnitrTTn* i/C Mo Chimtri WK 1 IDvMaHl DEVINE ENGINEERING 11884 Springside Rd San Diego, CA92128 (858) 748-6168 SHEET NO OF CALCULATED BY_ CHECKED BY SCALE HATE: DATE C? ^-ov o.o. onnnirrr-xix i /C nob Qhootci WK.I f Quorex Pharmaceuticals, Inc. TECHNICAL REPORT HAZARDOUS MATERIALS SUMMARY For 2075 Corte del Nogal, Suite J Carlsbad, CA 92009 July 11, 2001 OCCUPATIONAL SERVICES, INC Quorex Pharmaceuticals, Inc July 11, 2001 Technical Report / Hazardous Materials Summary Page 1 Quorex Pharmaceuticals, Inc will occupy 2075 Corte del Nogal, J, Carlsbad, CA 92009 This is a research and development facility performing bench scale science using typical laboratory quantities of hazardous materials Based upon the proposed volume and usage of hazardous materials, the proper occupancy classification for 2075 Corte del Nogal, Suites J, is "B" 2075 Corte del Nogal has one, 1- hour rated control area For detailed information concerning both the physical and health hazards at 2075 Corte del Nogal, Suite J, please refer to the enclosed two chemical classification reports based on 1997 UBC Tables 3D and 3E The building is equipped with an approved automatic sprinkler system None of the hazardous materials exceed the exempt amounts for physical or health hazards for storage or use CONTROLS The following controls are installed at 2075 Corte del Nogal, Suite J, Carlsbad, CA 1 Automatic Fire Extinguishing Systems [1997 UFC 1003 2 2] The building will be equipped with an approved automatic fire extinguishing system 2 Shelving and Lips/Guards [1997 UBC 307 1 3 (3) and 1997 UFC 8001 11 9] The laboratories will be equipped with adequately braced and anchored shelving of substantial noncombustible construction with a chemical resistant coating Shelves will be provided with a lip or guards Shelf storage of hazardous materials will be maintained in an orderly manner 3 Seismic Bracing Shelves greater than six feet high will be braced 4 Separation of Incompatible Materials [1997 UFC 8001 11 8] Incompatible materials will be separated from each other on shelving, in storage cabinets, and in waste collection containers Incompatible materials will be separated by one or more of the following methods Storage in separate storage cabinets Separation by a distance of more than twenty feet Isolation using noncombustible partitions greater than 18" high Chemists and biologists will receive chemical safety instruction on the separation of incompatible materials Furthermore, scientists will be trained not to exhaust mcompatibles into the ventilation systems 5 Empty Containers [1997 UFC 7902 5 3] The storage of empty containers and containers previously used for the storage of flammable or combustible liquids, unless free from explosive vapors, will be stored as required for filled containers and tanks Tank and containers, when emptied will have the covers or plugs immediately replaced in openings Quorex Pharmaceuticals, Inc Technical Report / Hazardous Materials Summary My 11,2001 Page 2 Security [1997 UFC 8001 11 2] The suite will be equipped with lock(s) to prevent unauthorized entry Fire Extinguishers /7997 UFC 7902 5121] The facility will be equipped with portable dry chemical fire extinguishers Flammable Liquid and Hazardous Materials Storage Cabinets [1997 UFC 7901 421 & [1997 UFC 8001 10 6] Flammable and combustible liquids will be stored in approved flammable liquid storage cabinets Doors will be well fitted, self-closing, and equipped with a latch The flammable liquid cabinets will meet the construction standards in 7997 UFC 7901 421 Hazardous materials including Highly Toxic Solids and Liquids, Oxidizer, Reactive, and Water Reactive materials will be stored in hazardous materials storage cabinets Doors will be well fitted, self-closing, and equipped with a latch The hazardous materials storage cabinets will meet the construction standards in 7997 UFC 8001 10 6 Laboratory Fume Hoods and Building Ventilation a Flammable Gases and Vapors in the Exhaust Systems The storage and use of flammable and combustible liquids and gases in hoods and exhaust ducts will be limited to the smallest amounts needed each day Concentrations of gases and vapors will be diluted to less than 10% of the lower explosive limit (L E L ) for each compound Therefore, no automatic fire protection systems will be required in the fume hoods or exhaust ducts Mechanical exhaust will be provided where Class I, II, or III-A liquids are used (in any amount) in Groups B, F, M, and S occupancies, or portions thereof The rate of exchange will exceed the minimum of six air changes per hour Under normal operating conditions explosive vapor-air mixtures will not develop at QUOREX PHARMACEUTICALS The majority of the work involving Class I, II, or III-A liquids will be performed in chemical fume hoods, not in the open laboratories The exhaust ventilation will be sufficient to maintain nonflammable and nonexplosive vapor concentrations throughout the entire exhaust duct system Quorex's activities will not require elevated temperatures Table 1 is a listing of the LEL for commonly used flammable liquids and gases Flammable Liquids and Gases Acetone Acetonitnle Cyclohexane Ethanol Ethyl Acetate Ethyl Ether Hexane Hydrogen Isopropanol LEL (%) 26 44 1 3 33 22 1 9 1 2 40 25 10%ofLEL(%)* 026 044 0 13 033 022 0 19 0 12 04 025 Quorex Pharmaceuticals, Inc Technical Report / Hazardous Materials Summary July 11,2001 Page 3 Flammable Liquids and Gases Methanol Pyndme Tetrahydrofuran Toluene LEL (%) 60 1 8 1 8 1 2 10% of LEL(%)* 06 018 018 012 *DuctsDucts conveying flammable vapors at concentrations greater wan 1U7<. LEL are required to be equipped with automatic fire protection systems Face Velocities Face velocities for laboratory fume hoods will not be less than the following Type General Use Use with Carcinogens Average Face Velocity 100lfpm 150lfpm Minimum Face Velocity 70 Ifpm 125lfpm 10 Water Reactive Materials [1997 UFC 8001 15234] Materials that react with water or other liquids to produce a hazard will not be stored in the same room with flammable or combustible liquids 11 Sources of Ignition [1997 UFC 7901 10] In locations where flammable vapors could be present, precautions will be taken to prevent ignition by eliminating or controlling sources of ignition Adequate grounding and bonding will be provided to prevent the accumulation of static electricity wherever Class I or II liquids are transferred or dispensed 12 Compressed Gases [1997 UFC 4904 2] Compressed gases in service and in storage will be adequately secured to prevent falling or being knocked over Cylinders, including empty ones, will have their caps in place and valves tightly closed If you have any questions regarding the contents of this report, please contact me at (619) 316-4955 Thank you Prepared for Quorex Pharmaceuticals, Inc by Occupational Services, Inc Brad Stanard, Health and Safety Specialist Quorex Pharmaceuticals Physical Hazard Report Summary Storage CLASS Location LABORATORY COMBUSTIBLE LIQUID CLASS II COMBUSTIBLE LIQUID CLASS III-A COMBUSTIBLE LIQUID CLASS III-B COMBUSTIBLE FIBER CRYOGENIC, FLAMMABLE OR OXIDIZING EXPLOSIVES FLAMMABLE SOLID FLAMMABLE, GAS FLAMMABLE LIQUID CLASS I-A FLAMMABLE LIQUID CLASS I-B FLAMMABLE LIQUID CLASS I-C ORGANIC PEROXIDE, DETONATABI.E ORGANIC PEROXIDES CLASS I ORGANIC PEROXIDES CLASS II ORGANIC PEROXIDES CLASS III ORGANIC PEROXIDES CLASS IV ORGANIC PEROXIDES CLASS V OXIDIZER CLASS 1 OXID1ZER CLASS 2 OXIDIZER CLASS 3 OXIDIZER CLASS 4 OXIDIZER - GAS OXIDIZER, GASEOUS OR LIQUIFIED PYROPHORIC UNSTABLE (REACTIVE) CLASS 1 UNSTABLE (REACTIVE) CLASS 2 UNSTABLE (REACTIVE) CLASS 3 Lbs Gallons 0000 0000 0000 0000 0000 0000 1 123 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 1 123 L588 0291 1 640 0000 0000 0000 0 000 0000 0000 50 153 0 139 0000 0000 0000 0000 0000 0000 0528 0000 0000 0000 0000 0000 0000 1 585 0000 0000 Cu. Ft. 0 000 0000 0000 0000 0 000 0000 0000 0000 0000 0000 0000 0000 0000 0 000 0 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Closed System Lbs. Gallons Cu. Ft. 0000 0000 0 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0 000 0000 0000 Open System Lbs. Gallons 0000 0000 0000 0000 0000 o ooo 0000 0 000 0000 0000 0000 0000 0000 0 000 0000 0 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0 000 0000 0 000 0000 5015 0000 0000 0000 0 000 0000 0 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Wednesday, July 11,2001 Page 1 of2 Quorex Pharmaceuticals Physical Hazard Report Summary Storage CLASS UNSTABLE (REACTIVE) CLASS 4 RADIOACTIVES WATER REACTIVE CLASS 1 WATER REACTIVE CLASS 2 WATER REACTIVE CLASS 3 NON HAZARDOUS Lbs. Gallons 0000 0000 1 101 1 322 0000 4706 0000 0000 1 070 0013 0000 0000 Cu Ft. 0000 0000 0000 0000 0000 1,2000 00 Closed System Lbs. Gallons Cu Ft 0000 0000 0000 0000 0000 0000 0000 0000 0 000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Open System Lbs Gallons 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Wednesday, July 11,2001 Page 2 of2 Quorex Pharmaceuticals Health Hazard Report Summary Location LABORATORY Storage CLASS CORROSIVES HIGHLY TOXICS IRRITANTS SENSITIZERS OTHER HEALTH HAZARDS TOXICS Lbs. 1 333 1 101 50 872 0111 17569 2599 Gallons 7 180 0000 59 754 0000 50 027 1 480 Cu Ft. 0000 0000 0000 0 000 0 000 0000 Closed System Lbs 0000 0 000 0000 0000 0000 0000 Gallons 0000 0000 0000 0000 0000 0000 Cu. Ft 0000 0 000 0000 0000 0000 0000 Open Lbs. 0 000 0000 0000 0 000 0000 0000 System Gallons 0000 0000 0 000 0 000 0000 0000 Wednesday, July 11,2001 Page 1 of 1 Inventory Report for Quorex Location LABORATORY Class COMBUSTIBLE LIQUID CLASS II (LIQUIDS) Cname CAS# Unit Quantity Quantity in Gallons Acetic Acid, Glacial Methyl-2,4-Pentanedione Methyltetrahydroturan-3-one 64-19-7 815-57-6 3188-00-9 L T T Summary for Gallons (3 detail records) Class COMBUSTIBLE LIQUID CLASS III-A Cname CAS# Unit Decyl Aldehyde Diethy] Pyrocarbonatc Hydroxytetrahydrofuran I lydroxytetrahydrofuran Mcthoxy-3-buten-2-onc Phenol Rose Oxide 112-31-2 1609-47-8 453-20-3 453-20-3 4652-27-1 108-95-2 16409-43-1 T T T T T L T Summary for Gallons (7 detail records) Class COMBUSTIBLE LIQUID CLASS III-B Cname CAS# Unit D1THIOTHEITOL DMSO EGTA FORMAMIDE - DE1ONIZED Glyccrol Hcxanoic Acid 27565^1-9 67-68-5 67-42-5 75-12-7 56-81-5 142-62-1 T L T T L T 6 1 585 5 0001 5 0001 Sum 1 588 (LIQUIDS) Quantity Quantity in Gallons 25 0 007 50 0013 5 0001 5 0001 10 0003 1 0264 5 0001 Sum 0291 (LIQUIDS) Quantity Quantity in Gallons 5 0001 4 1 057 100 0026 100 0026 1 0264 2 0001 Wednesday, Ju ly 11, 2001 Page 1 of 13 Twcen 20 9005-64-5 Summary for Gallons (7 detail records) Class CORROSIVES (LIQUIDS ) Cname CAS# Acetic Acid, Glacial Bulyryl Chloride Didiloromethane Hexanoic Acid Hydrochloric Acid Hydrogen Peroxide Isobutyl Chlorotbrmatc Phenol Sodium Hydroxide Tnchloroacetic Acid Tncthylamine 64-19-7 141-75-3 75-09-2 142-62-1 7647-01-0 7722-84-1 543-27-1 108-95-2 1310-73-2 76-03-9 121-44-8 Summary for Gallons (1 1 detail records) Class CORROSIVES (SOLID ) Cname CAS# Crystal Violet Hexadecyltnmethylammonium Bromide IM1DAZOLE Iron-Ill Chloride, Anhydrous Iron III Chloride, Hexahydrate Levuhnic Acid Lithium Chloride PHENYL-METHYL SULFONYL FLUORIDE Potassium Hydroxide Summary for Lbs (9 detail records) Wednesday, July 11,2001 548-62-9 57-09-0 288-32-4 7705-08-0 7705-08-0 123-76-2 7447-41-8 329-98-6 1310-58-3 L Unit L T L T L L T L L L T Unit M M M M M M M M M 1 Quantity 6 50 6 2 4 2 25 1 4 4 100 Quantity 25 25 100 100 100 50 100 5 100 0264 Sum 1 640 Quantity in Gallons 1 585 0013 1 585 0001 1 057 0528 0007 0264 1 057 1 057 0 026 Sum 7 180 Quantity HI Lbs. 0 055 0 055 0220 0220 0220 0 110 0220 0011 0220 Sum 1 333 Page 2 of 13 Class FLAMMABLE LIQUID CLASS I-B (LIQUIDS) Cname Acetomtnle UV Alcohol, Reagent Butyryl Chloride Ctiloro-2,4-pentanedionc Ethanol, 200 proof F.thyl Acetate Flammable Solvent Waste Isopropanol Methanol Pentanedione Pyridinc Tnethylamine CAS# 75-05-8 64-17-5 141-75-3 1694-29-7 64-17-5 141-78-6 000338-00-0 67-63-0 67-56-1 600-14-6 110-86-1 121-44-8 Summary for Gallons (12 detail records) Class FLAMMABLE LIQUID CLASS I-C Cname CAS# Isobutanol Isobutyl Chloroformate 78-83-1 543-27-1 Summary for Gallons (2 detail records) Class FLAMMABLE SOLID (SOLID ) Cname CAS# Charcoal Dinitrophenylhydrazine Summary for Lbs (2 detail records) 7440-44-0 119-26-6 Unit Quantity I. 20 I. 16 T 50 T 5 L 12 1. 8 G 30 L 4 L 16 T 25 T 100 T 100 (LIQUIDS) Unit Quantity T 500 T 25 Unit Quantity M 500 M 10 Quantity in Gallons 5284 4227 0013 0001 3 170 2 114 30000 1 057 4227 0007 0 026 0026 Sum 50 153 Quantity in Gallons 0132 0007 Sum 0 139 Quantity in Lbs. 1 101 0022 Sum 1 123 Wednesday, July 11,2001 Page 3 of 13 Class HIGHL Y TOXICS (SOLID ) Cname CAS#Unit Quantity Quantity in Lbs Muscimol Sodium Azide Summary for Lbs (2 detail Class IRRITANTS Cname Acelie Acid, Glacial Acetomtnlc UV Alcohol, Reagent Amy] Alcohol Butyryl Chloride Chloro-2,4-pentanedionc Chloroform Decyl Aldehyde Dichloromethanc Diethyl Pyrocarbonate DITHIOTIIEITOL DMSO EDTA EGTA Ethanol, 200 proof Ethidium Bromide Ethyl Acetate Flammable Solvent Waste FORMAMIDE - DE1ONIZED Glycerol Hcxanoic Acid 2763-96-4 26628-22-8 records) (LIQUIDS) CAS# 64-19-7 75-05-8 64-17-5 75-85-4 141-75-3 1694-29-7 67-66-3 112-31-2 75-09-2 1609-47-8 27565-41-9 67-68-5 6381-92-6 67-42-5 64-17-5 1239-45-8 141-78-6 000338-00-0 75-12-7 56-81-5 142-62-1 1 M Unit I. L L T T T L T L T T L T T L T L G T L T 1 500 Quantity 6 20 16 500 50 5 4 25 6 50 5 4 500 100 12 500 8 30 100 1 2 0000 1 101 Sum 1 101 Quantity in Gallons 1 585 5284 4227 0 132 0013 0001 1 057 0007 1 585 0013 0001 1 057 0132 0026 3 170 0 132 2 114 30000 0026 0264 0001 Wednesday, July 11,2001 Page 4 of 13 Hydrochloric Acid Hydroxytetrahydrofuran Hydroxytetrahydrofuran Isobutanol Isopropanol Methanol Methoxy-3-buten-2-one Mcthyl-l,3-Cyclopentanedione Mcthyl-1 ,3-Cyclopentanedione Methyl-2,4-Pentancdionc Mcthyl-2-Cyclopcntcn-l -one Methyl-2-Cyclopcntcn-l -one Methyltctrahydrofuran-3-one Pentanedione Pyridinc Rose Oxide Sodium Hydroxide Trichloroacctic Acid Triton X- 100 Twecn 20 Summary for Gallons (41 Class IRRITANTS Cname ACES Acctylcyclopentanone Adenine Adonitol Agar, Skim Milk Agar, TSA Blood Base 7647-01-0 453-20-3 453-20-3 78-83-1 67-63-0 67-56-1 4652-27-1 765-69-5 765-69-5 815-57-6 1120-73-6 1120-73-6 3 1 88-00-9 600-14-6 110-86-1 16409-43-1 1310-73-2 76-03-9 9002-93-1 9005-64-5 detail records) (SOLID) CAS# 7365-82-4 1670-46-8 73-24-5 10058-44-3 1120-73-6 1121-05-7 L T T T L L T T T T T T T T T T L L T L Unit M M M M M M 4 5 5 500 4 16 10 5 10 5 5 1 5 25 100 5 4 4 100 1 Quantity 25 5 1 1 500 500 1 057 0001 0001 0 132 1 057 4227 0003 0001 0003 0001 0001 0000 0001 0007 0026 0001 1 057 1 057 0026 0264 Sum Quantity m Lbs. 0055 0011 0002 0002 1 101 1 101 59 754 Wednesday, July 11,2001 Page 5 of 13 Agarose, General Purpose Agarose, Low Melting Point Agarose, Small Fragments Ammonium Acetate Ammonium Chloride Ammonium Sulfate Ampicillm Bone Acid Bromophenol Blue Broth, I.B Miller Broth, Phenol Red Base Calcium Chloride, Dihydratc Cinoxacm Coomassie Brilliant Blue R-250 Cystcme Mydrochlonde Monohydrate Dihydro-2-Methylfuran Dihydrouracil Dinitrophenylhydrazmc Hthyl-2,4-Pentanedione Ethyl-2-Ilydroxy-2-Cyclopcnten-l-one Ficoll Glucose, Anhydrous GLYCINE HEPES Hydantom Hygromycm B Iodine IPTG IPTG Iron III Chloride, Anhydrous Iron III Chloride, Hexahydrate 39346-81-1 39346-81-1 1128-23-0 631-61-8 12125-02-9 7783-20-2 69-52-3 10043-35-3 1 1 5-39-9 130-40-5 13436-46-9 10035-04-8 28657-80-9 6104-59-2 226267-70-9 25564-22-1 504-07-4 119-26-6 3859-41-4 4338-47-0 26873-85-8 488-86-8 56-40-6 7365-45-9 461-72-3 31282-04-9 7553-56-2 367-93-1 367-93-1 7705-08-0 7705-08-0 M M M K M K M K M M M M M M M M M M M M M K. M M M I M M M M M 100 25 100 1 500 1 25 1 5 500 500 500 1 25 25 5 1 10 5 25 10 1 500 100 25 50 30 5 1 100 100 0220 0055 0220 2203 1 101 2203 0055 2203 0011 1 101 1 101 1 101 0002 0055 0055 0011 0002 0022 0011 0055 0022 2203 1 101 0220 0 055 0000 0066 0011 0002 0220 0220 Wednesday, July 11,2001 Page 6 of 13 Kmelin Riboside Laurie Acid Lithium Chloride Lithium Dodccyl Sulfate Lyso/yme, Egg White Magnesium Chloride, Hexahydrale Magnesium Sulfale, Heptahydrate Manganese Chloride MES MOPS NADPH Phenol Red Piperacillm POLYETHYLENE GLYCOL - (8,000 MW) Potassium Acetate Potassium Chloride Potassium Phosphate, Dibasic Potassium Phosphate, Monobasic Potassium Sulfate Potassium Tetraborate Tetrahydrate Ribosc Ribosc Ribtilosc Roxithromycm Sodium Acetate, Anhydrous Sodium Bisulfite Sodium Chloride Sodium Citrate Sodium Phosphate, Dibasic Anydrous Sodium Phosphate, Monobasic Monohydratc Sorbose 4338-47-0 143-07-7 7447-41-8 2044-56-6 12650-88-3 7786-30-3 10034-99-8 13446-34-9 4432-31-9 1132-61-2 765-69-5 143-74-8 59703-84-3 25322-68-3 127-08-2 7447-40-7 7758-11-4 7558-80-7 7778-80-5 12045-78-2 979-92-0 979-92-0 979-92-0 80214-83-1 127-09-3 7631-90-5 7647-14-5 6132-04-3 7758-29-4 7758-29-4 87-79-6 I M M M M M M M K K 1 M M K M M M M M M I M 1 M M M K M M M 1 100 2 100 25 5 500 500 125 1 1 25 5 1 1 500 500 500 500 500 500 250 10 25 1 500 500 2 100 500 500 100 0000 0004 0220 0055 0011 1 101 1 101 0275 2203 2203 0000 0011 0002 2203 1 101 1 101 1 101 1 101 1 101 1 101 0001 0022 0000 0002 1 101 1 101 4405 0220 1 101 1 101 0000 Wednesday, July 11,2001 Page 7 of 13 Sorbosc Sulfisoxazole SULFOSAUCYCLIC ACID Tetracyclme Thiamme Hydrochlonde Tobramycin Tns Tns-HCl Trypan Blue Tryptophan Urea Vancomycin XYLUNECYANOLPF Xylilol Yeast Extract Zinc Chloride Zingerone 87-79-6 127-69-5 5965-83-3 60-54-8 67-03-8 32986-56-4 77-86-1 77-86-1 72-57-1 73-22-3 57-13-6 1404-93-9 4463-44-9 87-99-0 8013-01-2 7646-85-7 122-48-5 Summary for Lbs (85 detail records) Class NON HAZARDOUS (GAS ) Cname CAS# NITROGEN, COMPRESSliD 7727-37-9 Summary for Cu Ft (1 detail record) Class NON HAZARDOUS (SOLID ) Cname CAS# Agar ALBUMIN Arabmose Deuterium Oxide 9002-18-0 9048-46-8 5328-37-0 7789-20-0 M M M M M M K M M M K 1 M M M M M Unit c Unit M M M M 1 25 125 25 100 5 1 500 25 25 1 250 25 5 500 100 5 Sum Quantity Quantity in 1200 Sum Quantity Quantity in 500 25 100 5 0002 0055 0275 0055 0220 0011 2203 1 101 0055 0055 2203 0001 0055 0011 1 101 0220 0011 50872 Cu. Ft. 1 ,200 000 1,200000 Lbs 1 101 0055 0220 0011 Wednesday, July 11,2001 Page8ofl3 Enoxacm Fructose Gelatin, Nutrient Ilomoserme Jasmone Sodium Bicarbonate Sucrose Summary for l.bs (1 1 detail records) Class OXIDIZER CLASS Cname 84294-96-2 57-48-7 488-10-8 672-15-1 672-15-1 144-55-8 57-50-1 1 M M 1 M M M / (LIQUIDS) CAS# Unit Hydrogen Peroxide 7722-84-1 Summary for Gallons ( 1 detail record) Class OTHER HEALTH HAZARDS Cname CAS# Acetic Acid, Glacial Alcohol, Reagent Chloroform Dichloromcthane DMSO IIDJA Clhanol, 200 proof Ethldium Bromide Flammable Solvent Waste I-ORMAMIDH - DEIONIZED Glyccrol Hexanoic Acid Hydrochloric Acid Isobutanol 64-19-7 64-17-5 67-66-3 75-09-2 67-68-5 6381-92-6 64-17-5 1239-45-8 000338-00-0 75-12-7 56-81-5 142-62-1 7647-01-0 78-83-1 500 1 500 250 5 500 500 Sum Quantity Quantity L 2 Sum (LIQUIDS) Unit Quantity Quantity L 6 L L L L T L T G T L T L T 16 4 6 4 500 12 500 30 100 1 2 4 500 0001 0002 1 101 0001 0011 1 101 1 101 4706 in Gallons 0528 0528 in Gallons 1 585 4227 1 057 1 585 1 057 0 132 3 170 0 132 30000 0026 0264 0001 1 057 0132 Wednesday, July 11,2001 Page 9 of 13 Isopropanol Methanol Phenol Tncthylamme Triton X-100 67-63-0 67-56-1 108-95-2 121-44-8 9002-93-1 I. L L T T 4 16 1 100 100 1 057 4227 0264 0026 0026 Summary for Gallons (19 detail records) Sum Class OTHER HEALTH HAZARDS (SOLID ) Cname Ammonium Chloride CAS# 12125-02-9 Unit Quantity Quantity in Lbs. M 500 Lithium Chloride 7447-41-8 M 100 1 101 Ammonium Sulfatc Ampicillm Biotm Broth, LB Miller Chloramphcmcol Crystal Violet lirythromycin Glutathione Iodine IPTG 1PTG Kanamycin Sulfale 7783-20-2 69-52-3 58-85-5 130-40-5 56-75-7 548-62-9 114-07-8 70-18-8 7553-56-2 367-93-1 367-93-1 25389-94-0 K M 1 M M M M M M M M M 1 25 500 500 100 25 50 10 30 5 1 10 2203 0055 0001 1 101 0220 0055 0 110 0022 0066 0011 0002 0022 0220 Magnesium Sulfatc, Heptahydrate Manganese Chloride MOPS Muscimol Nitnlotnacetic Acid Phenol-Red Broth Base PHENYL-METHYL SULFONYL FLUORIDE 10034-99-8 13446-34-9 1132-61-2 2763-96-4 139-13-9 83-88-5 329-98-6 M M K I M M M 500 125 1 1 100 500 5 1 101 0275 2203 0000 0220 1 101 0011 50 027 Wednesday, July 11,2001 Page 10ofl3 Potassium Tctraborate Tetrahydrale Ribollavin Sodium Bisulfite Streptomycin Sulfate SULFOSALICYCLIC ACID Tetracyclmc Tobramycin Tns Trypan Blue Urea Zinc Chloride 12045-78-2 83-88-5 7631-90-5 3810-74-0 5965-83-3 60-54-8 32986-56-4 77-86-1 72-57-1 57-13-6 7646-85-7 M M M M M M M K M K M 500 10 500 100 125 25 5 1 25 1 100 1 101 0022 1 101 0220 0275 0055 0011 2203 0055 2203 0220 Summary for Lbs (32 detail records) Sum 17569 Class UNSTABLE (REACTIVE) CLASS 1 (LIQUIDS) Cname CAS# Acetic Acid, Glacial 64-19-7 Unit Quantity Quantity in Gallons L 6 1 585 Summary for Gallons (1 detail record) Sum 1 585 Class UNSTABLE (REACTIVE) CLASS 3 (SOLID) Cname CAS#Unit Quantity Quantity in Lbs. Dinitrophenylliydrazme Sodium Azidc 119-26-6 26628-22-8 M M 10 0022 500 1 101 Summary for Lbs (2 detail records) Class SENSITIZERS (SOLID) Cname CAS# Lithium Dodecyl Sulfatc 2044-56-6 Tnmethoprim 738-70-5 Vancomycm 1404-93-9 Sum Unit Quantity Quantity in Lbs ~M 25 0055 M 25 0 055 i "250 ~b"oo! 1 123 Wednesday, July 11,2001 Page 11 of 13 Summary for Lbs (3 detail records) Sum 0111 Class TOXICS (LIQUIDS) Cname CAS#Unit Quantity Quantity in Gallons Ethidium Bromide Phenol Trichloroacetie Aeid Tnethylamine Summary for Gallons (4 detail records) Class TOXICS (SOLID ) Cname Bromophenol Blue Chloramphemcol Crystal Violet Hexadecyltnmethylanimonium Bromide 1MIDAZOLE Lithium Chloride Potassium Hydroxide Sodium Bisulfite Streptomycin Sull'ate Jnmethoprim "Zinc Chloride » Summary for Lbs (11 detail records) Class. WATER REACTIVE Cname Dicthyl Pyrocarbonatc Sodium Hydroxide 1239-45-8 108-95-2 76-03-9 121-44-8 CAS# 115-39-9 56-75-7 548-62-9 57-09-0 288-32-4 7447-41-8 1310-58-3 7631-90-5 3810-74-0 738-70-5 7646-85-7 CLASS CAS# 1609-47-8 1310-73-2 T L L T Unit M M M M M M M M M M M 500 1 4 100 Quantity 5 100 25 25 100 100 100 500 100 25 100 1 (LIQUIDS) Unit Quantity T L 50 4 0 132 0264 1057 0026 Sum 1 480 Quantity in Lbs. 0011 0220 0055 0055 0220 0220 0220 1 101 0220 0055 0220 Sum 2 599 Quantity in Gallons 0013 1 057 Wednesday, July 11,2001 Page 12 of 13 Summary for Gallons (2 detail records) Sum Class WA TER REA CTIVE CLASS 1 (SOLID ) Cname CAS# Unit Quantity Quantity in Lbs 127-08-2 MPotassium Acetate 500 1 101 Summary tor Lbs (1 detail record) Sum Class WA TER REA CTIVE CLASS 2 (LIQUIDS) Cname CAS# Unit Quantity Quantity in Gallons TButyryl Chloride 141-75-3 50 0013 Summary tor Gallons (I detail record) Sum Class WA TER REA CTIVE CLASS 2 (SOLID ) Cname CAS# Unit Quantity Quantity in Lbs. 1310-58-3 26628-22-8 1 070 1 101 0013 Potassium Hydroxide M 100 Sodium Azide M 500 0220 iloT Summary for Lbs (2 detail records) Sum I 322 Wednesday, July 11,2001 Page 13 of 13