Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; 100; CB053199; Permit03-09-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB053199 Building Inspection Request Line (760) 602-2725 Job Address: 2200 FARADAY AV CBAD St: 100 Permit Typ13: Tl Sub Type: INDUST 0 Parcel No: 2121203700 Lot#: Status: Valuation: $1,967,140.00 Construction Type: VN Applied: Occupancy Group: Reference #: Entered By: Project Title: DOT HILL-OFFICE/LAB TO OFFICE/ LAB.56,204 SF-NEW WALLS,ELECT,MECH Plan Approved: Issued: Applicant: DONALD PITMAN STE 290 3900 5TH AV 92103 Building Permit Add'! Building Permit Fee Plan Check Add'! Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'! Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $5,030.49 $0.00 $3,269.82 $0.00 $0.00 $413.10 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Inspect Area: Plan Check#: Owner: E QB P-1 LL C ATTN: CHAD CARPENTER 800 SILVERADO_ ST #300 LA JOLLA CA 92037 Meter Size Add'! Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees ISSUED 09/12/2005 LSM 11/03/2005 11/03/2005 RB $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $69.00 $185.00 $0.00 $0.00 $0.00 $0.00 $0.00 TOTAL PERMIT FEES $8,967.41 Total Fees: Inspector: $8,967.41 Total Payments To Date: $8,967.41 Balance Due: $0.00 ~llf DING PLANS -~ IN STORAGE "'51:a.r,ne,p _ATTACHED FINAL APPRO\f AL/ Date: 5, 1 1-(JIG:::;,_ Clearance: ------ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to his or s o which the statu e of limitations has reviousl o herwise ex ired. 0525501-2 0050 09/12/2005 001 11 FOR OFFICE USE ONLY . PERMIT APPLICATION PLAN CHECK NO. (!6():53/C}<g CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. } q ({) 7 / 'f0 , Plan Ck. Deposit1 ~.a.h-'l.~;).. Validated By ___ .....:a..'-(/_ .uA_V\../ _____ _ Date 9J { I c9-/ 1()5 Seit Address (include Bldg/Suite #) Business Name (at this address) Unit No. Phase No. Total # of units Proposed Use Description of Work SQ. F . # of Bedrooms # of Bathrooms ltJeuJ Wltl.LS :?-_-"cQ~'tMT'P..EIISOl'fllt-iliffeten( fromapplicpntl', . , -· . State/Zip FaxR,_ , :-,,.~ Add_,~-_n. • e ow ,· J>/,1":(I~ 5 City .lh~-~---State/Zip 0, Telephone# ',,~., 1l~J, .,· - Name Address City State/Zip Telephone# ·5. ·· c;o~:t:RA,CTQfb COJVIPANY ll!MYIJ;' ,, (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). Wh.tt-e. CoM·h--~c.,.Jc',e,v... , ;i::.-.c., ~L,SJ3~'C> c±--% 'l2.e00 7&0 ... 't'll-/l-'$0 Name ' Address City State/Zip ~phone # State License # 4 -s 2, 5 r) License Class 1s City Business License # 1 '2. t,2.., 8 0 Designer Name Address City State/Zip Telephone State License # _________ _ ~~;-i~,,WQ,Ri~R~'v e()M~~NSJ\Tl,QN "', ' ' '~ , -V:, , --~$ ' -' Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the rk for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which his ermit is rssued. My worker's compensation insurance carrier and policy number are: ' Insurance Company S:rer.-r-'E' £CA.NJ> Policy No. fs'1 'o · 2ob 5" Expiration Date_/+---.'--=-='--- (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100) OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to t Wozt:ke ' Comp sation Laws of California. WARNING: Failure ecur 'orkers' c pensation coverage is unlawful, and shall subject an employer to criminal pen tie and civil fines up to one hundred thousand dollars ($ , _ ,n additi o the c of compensation, damages as provided for in Section 3706 of the Lab co e, interest and attorney's fees. SIGNATURE _ _,,,~'E:.4~FC'----"'1'"'--.....::,----------------DATE_/,~'/..,,.,.-+-~----- '7,~: 'J>WN,J;fl".:P._ ,LQ!:,S: pi;c:. .. -,, , _ ~. -, ., . . ,.' . , . I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): _______________________________________________________ _ PROPERTY OWNER SIGNATURE _____________________ _ DATE _________ _ '.CQMl,'~J;t:$)Jil~ ~!::GiJ:10~ FQ!'f tJQNJ/JffeSfDEN;'iJAt ;~u11;1;IN.G·e~~IVl!TS ON,v , Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES D NO IFANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~~L.:..,.Q.Q~~TllQ~T:IQJ'fl,,,1;11,QJf{G ~q;N<t( ,,, ''.,', .. , , , , . , ·_ .. ,., , ,-, I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME______________ LENDER'S ADDRESS ________________________ _ !Q,;--,~ee~1G~ti1r'g~_ijJtf_1qro-10~-.-_ -:_ :-.: , , ,,,· ,, -. _ -: __ ._ · I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit~ of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is requir EXPIRATION: Every permit issue authorized by such permit is not co at any time after the work is co YELLOW: Applicant PINK: Finance City of _Carlsbad Bldg Inspection Reql:J_e~_t _____ _ For: 03/08/2006 Permit# CB053199 Title: DOT HILL-OFFICE/LAB TO OFFICE/ Description: LAB.56,204 SF-NEW WALLS,ELECT,MECH Type:TI Job Address: Sub Type: INDUST 2200 FARADAY AV Suite: 100 Lot 0 Location: APPLICANT DONALD PITMAN Owner: EQUASTONE 2200 FARADAY LLC Remarks: Total Time: CD Description 19 Final Structural ~/J Comment 1!L ~~ 'h Inspector Assignment: RB Phone: 7602711127 Inspector: ----- Requested By: NA Entered By: JANEAN 29 Final Plumbing 39 Final Electrical t--- 49 Final Mechanical Comments/Notices/Hold Associated PCRs/CVs Original PC# lnsgection Histoi:y Date Description Act lnsp Comments 02/06/2006 34 Rough Electric AP RB CEILING 02/06/2006 44 Rough/Ducts/Dampers AP RB COMPLETE SYSTEM 01/20/2006 17 Interior Lath/Drywall AP RB ON 1-19-06. 01/20/2006 18 Exterior Lath/Drywall WC RB 01/19/2006 17 Interior Lath/Drywall AP RB @ RSTROOM SHOWERS 01/19/2006 18 Exterior Lath/Drywall WC RB 01/19/2006 44 Rough/Ducts/Dampers CA RB 01/18/2006 14 Frame/Steel/Bolting/Welding AP RB @ SHOWER AREA 01/18/2006 24 Rough/Topout AP RB 01/18/2006 34 Rough Electric AP RB 01/13/2006 14 Frame/Steel/Bolting/Welding NR TP 01/13/2006 17 Interior Lath/Drywall AP TP patch 1 hr wall @ entry to suite 01/13/2006 24 Rough/Topout NR TP CIIY of Carlsbad · Final Building Inspection Dept: Building Engineering Planning CMWD S!Lit~ Plan Check#: Date: 03/07/2006 Permit#: CB053199 Permit Type: Tl Project Name: DOT HILL-OFFICE/LAB TO OFFICE/ Sub Type: IN DUST LAB.56,204 SF-NEW WALLS,ELECT,MECH Address: 2200 FARADAY AV #100 Lot: 0 Contact Person: BUEY Phone: 7605356201 Sewer Dist: CA Water Dist: CA 'i;~::;:~1"11""111:tJJllll~ .. ,, ................... ~:~~~:~~:·t4~ ...... =~·;~~~~: ... : .... ::~~~~:=~~:·_ .. _ ... _ .. _ ... p Inspected Date By: ___________ Inspected: ______ Approved: ___ Disapproved: __ Inspected Date By: ___________ Inspected: ______ Approved: ___ Disapproved: __ 1•111111111•••••••••••11111 II•••••• 111111111111111111111111111111111111111111111111111111111111111111111111111 Ill Ill 111111111111111111111111111111111111111 Comments: -------------------------------- DATE: October 20, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 053199 EsGil Corporation In <Partnersliip witli government for (}Jui{tfing Safety SET: III PROJECT ADDRESS: 2200 Faraday Ave PROJECT NAME: T.I. for Equus Realty Acquisitions .------CJ-APPl::-l~NT ~ CJ PLAN REVIEWER CJ FILE i:;gj The plans transmitted herewith have been correc~ed where necessary and substantially comply with the jurisdiction's building codes. ·. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted_ for recheck. · ~/:-,: D The applicant's copy of the che~k list is enclosed for the jurisdiction to forward to the·applicant contact person. D The applicant's copy of the check list has been sent to: i:;gj Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person D REMARKS: By: Abe Doliente Enclosures: Esgil Corporation D GA D MB D EJ D PC 10/20/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 .4t DATE: October 12, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 053199 EsGil Corporation In (J!artnersliip witli <Jovernment for <Bui{ain9 Safety SET:II PROJECT ADDRESS: 2200 Faraday Ave PROJECT NAME: T.I. for Equus Realty Acquisitions D APP CANT JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and r~submitted for a complete recheck. !ZI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [g'j The applicant's copy of the check list has been sent to: Donald Pitman Design, Inc. 3900 Fifth Avenue, San Diego, CA 92103 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Donald Pitman {v. ,.,,,\ Telephone#: 619/299-0011 Date ~~lo~J.i..-t>J""(by: 8'k.,) Fax #: -5544 Mail Telephonev Fax,......... In Person D REMARKS: By: Abe Doliente Esgil Corporation D GA D MB D EJ D PC Enclosures: 10/4/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 053199 October 12, 2005 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2200 Faraday Ave DATE PLAN RECEIVED BY ESGIL CORPORATION: 10/4/05 REVIEWED BY: Abe Doliente FOREWORD (PLEASE READ): PLAN CHECK NO.: 053199 SET: II DATE RECHECK COMPLETED: October 12, 2005 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following .items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new complete sets of prints to: Esgil Corp. or to the bldg. dept. of the juris. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo Carlsbad 053199 . October 12, 2005 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123; (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. 8. Specify lever-type hardware for passage doors on floors accessible to the disabled. Title 24. 9. In areas where the occupant load is at least 50, two exits are required. See the conference room 62 .. Table 10-A. See correction item no. 12. 10. Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served. Section 1004.2.4. 11. The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 1004.2.3.1. 12. Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply. Section 1004.2.2. 13. Clearly show the exiting for the lunch room 12. 14. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1003.2.8.2. 15. Show that exits are lighted with at least one foot candle at floor level. Section 1003.2.9.2. 16. Show the locations of existing exits from the building and show the path of travel fro_m the remodel area to the existing exits. Carlsbad 053199 October 12, 2005 17. Exit doors should swing in the direction of exit travel when serving any hazardous area or when the area served has an occupant load of 50 or more. Section 1003.3.1.5. Recheck conference room 62 18. Please see the following corrections for electrical, energy, plumbing and mechanical. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at Esgil Corporation. Thank you. EsGil Corporation In <Partnersliip witli <;;011ernment for (}Jui(aing Safety DATE: September 23, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 053199 PROJECT ADDRESS: 2200 Faraday Ave SET:I PROJECT NAME: T.I. for Equus Realty Acquisitions CJ~ANT ~ CJ PLAN REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies ·identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and ~~submitted for a complete recheck. [gj The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. · [gj The applicant's copy of the check list has been sent to: Donald Pitman Design, Inc. 3900 Fifth Avenue, San Diego, CA 92103 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [gj Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Donald Pitman Telephone#: 619/299-0011 Date contacted: 1 / 2-C~· /D.S(by: l'-) Fax #: -5544 Mail Telephone .../'. Fax / In Person D REMARKS: By: Abe Doliente Esgil Corporation D GA IZI MB IZI EJ D PC Enclosures: 9/13/05 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 053199 September 23, 2005 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 053199 OCCUPANCY: B TYPE OF CONSTRUCTION: V-N ALLOWABLE FLOOR AREA: Existing SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: September 23, 2005 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Offices ACTUAL AREA: T. I. only -56,204 SF STORIES: 2 HEIGHT: OCCUPANT LOAD: 562 (T.I. only) DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/13/05 PLAN REVIEWER: Abe Doliente This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy} where each correction item has been-addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPEqlFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot Carlsbad 053199 September 23, 2005 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and .calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans a·re signed. Business and Professions Code. 2. Indicate the use of all spaces adjacent to the area being remodeled or improved. 3. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or-rated corridors. Identify and provide construction details for proposed new fire rated walls. 4. Provide a section view of all new interior partitions. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). c) Wall sheathing material and details of attachment (size and spacing of fasteners). d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 5. Note on plan that suspended ceilings shall comply with UBC Tables 25-A, 16-0 and 16-B. 6. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.~..). Section 708. .... Carlsbad 053199 September 23, 2005 7. The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24. 8. Specify lever-type hardware for passage doors on floors accessible to the disabled. Title 24. 9. In areas where the occupant load is at least 50, two exits are required. See the conference room 62 .. Table 10-A. See correction item no. 12. 10. Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served. Section 1004.2.4. 11. The maximum number of required exits and their required separation must be maintained until egress is provided from .the structure. Section 1004.2.3.1. 12. Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply. Section 1004.2.2. 13. Clearly show the exiting for the lunch room 12. 14. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1003.2.8.2. 15. Show that exits are lighted with at least one foot candle at floor level. Section 1003.2.9.2. . 16. Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits. 17. .Exit doors should swing in the direction of exit travel when serving any hazardous area or when the area served has an occupant load of 50 or more. Section 1003.3.1.5. Recheck conference room 62 • MISCELLANEOUS 18. Please see the following corrections for electrical, energy, plumbing and mechanical. 19. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 20. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. .,. Carlsbad 053199 September 23, 2005 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at Esgil Corporation. Thank you. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. • REMODELS, ADDITIONS AND REPAIRS 1. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. d) Existing drinking fountains (if any) must be shown to comply with all accessibility features. e) Existing public telephones (if any) must be shown to comply with all accessibility features. Carlsbad 053199 September 23, 2005 ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti • ELECTRICAL (2002 NATIONAL ELECTRICAL CODE) 1. Electrical plans are ok. • ENERGY CONSERVATION 2. Please correct the mechanical energy forms to demonstrate compliance. 3. The completed and signed ENV-1and MECH-1 forms must be imprinted on the plans. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING and MECHANICAL CORRECTIONS PLAN REVIEWER: Eric Jensen 1. The licen_sed designer must sign the approved set of the plans. 2. If building spaces are used as plenums: a) Clearly show that all material exposed within the plenum complies with UMC Section 605.0: "Materials shall have a mold-, humidity-, and erosion-resistant face that meet the requirements of UL 181." b) Clearly show that all combustible materials exposed within the plenum space must comply with UMC Section 602.2. Flame-spread index of not more than 25 and a smoke-developed rating of not more than 50. c) A combustion products vent, vent connector, chimney, or chimney connector shall not extend into or through an air duct or plenum. UMC Section 804.0. d) Environmental and/or product-conveying duct systems shall not extend into or through ducts or plenums. UMC Sections 504.1 (Environment) & 505.1 (Product conveying). Carlsbad 053199 September 23, 2005 3. Provide data on the proposed hazardous materials to be stored and used. UBC 307 and UFC. Present the description of the hazardous materials in a format that coincides with the material classifications found in UBC Tables 3-D and 3-E. a) Clearly show the types of hazardous materials being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Include the material safety data sheets (MSDS), if applicable. b) Clearly show the amounts for each type of hazardous material to be stored and in use. c) Clearly show the locations in the building where each type of hazardous material is being stored or used. PLUMBING (2000 UNIFORM PLUMBING CODE) 4. The plumbing ·is limited to a couple of showers, a new break room sink, and the condensate removal. It is approved as submitted. MECHANl_~AL (2000 UNIFORM MECHANICAL CODE) 5. The boilers(?) are shown on sheet M2.1 but are not detailed or schedule(d) any where. Please clarify. 6. Detail exhaust ventilation system compliance with UMC Chapters 5 & 6. a) Detail the required make-up air as p~r UMC 505.3 b) Detail the exhaust outlet clearances as per UMC 504.5 (Environmental) & 506.9 (Product conveying). c) Clearly show the type of material to be exhausted by each exhaust system. d) Clearly show the duct materials are suitable for the intended use. UMC 506.1 & 610.1 e) Clearly show the exhaust duct material and gage used for each duct size. UMC Table 6-7 f) Separate and distinct systems shall be provided for incompatible materials. UMC 505.1 g) Detail ducts conveying explosives or flammable vapors, fumes or dusts shall extend directly to the exterior of the building without entering other spaces. UMC 505.1 h) Detail minimum duct conveying velocities as per UMC 505.2 and Table 5- 1 i) Detail duct cleanouts as per UMC Section 506.3 j) Detail required explosion venting of dust collection systems as per UMC 506.4 & 610.4 Carlsbad 053199 September 23, 2005 k) Detail duct support as per UMC 506.5 & 610.5 I) Detail fire protection as per UMC 506.6 & 610.6 m) Detail clearances from combustibles as per UMC 506.7 & 610.7 n) Detail protection from physical damage as per UMC 506.8 & 610.8 7. In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or Ill-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour. Such mechanical exhaust shall be taken from a point at or near the floor. UBC 1202.2.2. 8. "Equipment, machinery or appliances which generate finely divided combustible waste or which use finely divided combustible material shall be equipped with an approved method of collection and removal." UBC 306.8 9. Laboratories and make-up air supplied but no exhaust fans? Please clarify the use of the lavatories and provide any additional mechanical design (Fume hoods?)asnecessary. ·- 10. Recirculation of contaminated air in the laboratory or production areas may be a problem depending upon the operational clarification. Please review. 11. Large duct over large electrical service. How does this design comply with NEC 110-26(F)? 12. Return air shall not be obtained from the following locations: UMC Section 906.6. a) Where it will pick up objectionable odors, fumes, or flammable vapors. b) A hazardous or unsanitary location, or a refrigeration machinery room. c) A room or space containing fuel-burning equipment. d) A closet, bathroom, toilet room, or kitchen. e) A dwelling unit other than the room in which the air originates. 13. Detail the primary and secondary mechanical condensate waste design: Pipe sizing, routing, and termination areas. UMC 310.0 & UPC 807.2 ENERGY CONSERVATION 14. Include all "Parts" of energy forms MECH-1onto the plans. Be sure they match the submitted packet. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 053199 September 23, 2005 I VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 053199 PREPARED BY: Abe Doliente DATE: September 23, 2005 BUILDING ADDRESS: 2200 Faraday Ave BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V-N BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Office T.I. 56204 per city ·- Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance _'! I Plan Check Fee by Ordinance -r -I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee [3 Repeats Comments: D Other D Hourly .__ ___ _,I Hour* Esgil Plan Review Fee ($) 1,967,140 1,967,140 $5,030.491 $3,269.821 $2,817.071 Sheet 1 of 1 macvalue.doc DD Facilities Management Zone: -_,'J'--- CFD (in/out) #_Date of participation: ____ Remaining net dev acres: __ _ Circle One (For non-residential development: Type of land used created by this permit: ____________________ _, Legend: ~ Item Complete D Item Incomplete -Needs your action Environmental Review Required: YES NO TYPE ---- DATE OF COMPLETION: --------- Comp Ii an c e with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE ---- APPROVAURESO. NO. ______ DATE __ PROJECT NO. ________ _ OTHER RELATED CASES: _________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Appro_val: _______________________ _ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES__ NO __ CA Coastal Commission Authority? YES __ NO __ If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: NO_ 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. lnclusionary Housing Fee required: YES NO (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data· Entry Completed? YES·_-_ NO-__ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 ' . i ·t]D bo ·o·D ~:oo @oo . . 1, Provide: a .fully d.imensional $ite plan. drawn to scale, Show: .. North arrow, property Unes, · easements, existing anc:f proposed structures, streets; existing street improvem~nts, right-;of-W?JY width, dimension~!. setbacks ·anc;I existing tt'!p9graphicijl lines (including all $_ide and. rear yard. · slppe·s). " . . . . . . . . . . . 2. Provide :legal description of property and assessor'$;:parcel number.. t Policy 44-Neigh_bort,ood Architectµral Desi~11· Gµidelioe$ 1, Applicability:. YES No_, -,---- 2. · Project.complies Y~S _______ . NO .... · . ..;.._,;, ____ Zoning: 1 .. Setbacks: Front: Interior Side: Street Side: · Rear: Top of slope: Required--------,-,--,-,.---Shown _________ _ Required.. Shown ______ _ . Required · Shown ____ -'------- Required Shown ___________ _ Required Shown_. _____ _ 2. Ac9essory stn,.1cture setbacks: Front: Required Shown Inferior Side: Required Shown · Street Side: Reqµired ,Shown Rear: Required. Shown Str'uc~!Jre·sepafatio.ri: Re.quired· Shown 3'. 'Lot Covera!;Je: Required Shown, 4. Height: Required Shown. ·5: Parking: Spaces Required___, ______ ___.. ____ . Shown_-'-------- . (breakgown by U$es for commercii:il ijnq industrial projects required) ResidehtiaLGuest $paces Required · · ~ Shown . · -~ $ . -. Additional Cornments. Correction ·#J --Please .shaw on Sheet 1 .the total number of parking ·spaces . provided and required on site for· each ·use per Chapter 2t.44. Correction #2 -Is there ·any proposed rcrbf mounted eq.uipment associated with.this building permit? If SO; will the equipment be screened .by an existing parapet wall· or·· is. new iscreening materiaf required? Piease see· the attached handouts for examples. . . . . . . . . H:\ADMIN\CQ!JNTER\BldgPlnchkRevcti:k!st Rev 9(01 -·-·.· ' . ' . .. . .. PLANN1N01eN01r1eeR1Nc· AP.PRov Ais · · · ·_ .· . . . . T •• ,. \ PERMIT NUMBER CB V53Z92 DATE .• :: ·• : : i:_ ~ • RESIDENTIAL ··: _: ·· · . · -. ..:. :: -. . . .... . TENANT IMPROVEMENT . . ·' . . .t-i, l:.:RESJDEN.TIAL-=ADDITIOrt:MJNDR .. ~-:-.'l!.:-u· ·. -· .. PLAZA~-CJ.UIJNO--REAI. . _. -..... $10 ODO 00) . . . ' .:·,.··. .,. •. '· . ·-.. f < 1 • ·. · . ,v;.s .: .:1 ·. ' • ••• '& •• .. ·~ I, -: _ .. :· ·~: .. . . -..... ·: . '":: of·.-·.• : • c~~-~-AD COMPANY STOR&s . ~ , .. VILLACE FAIRE · -... COMPlETE ~OFFICE,BUILDING-: ... • f -PLANNER ________ _;,·:;_·· .;..;.· ·...:;;;·· =;;;;----------==D=--A=T-=-E'-=---___ _...:,__ _______ _ DATE ffr/os. I, { Carlsbad Fire Department Plan Review Requirements Category: TI , INDUST Date of Report: 09-29-2005 Reviewed by: ~?U ~ ~ Name: Address: Permit #: CB053199 DONALD PITMAN STE 290 3900 5THAV SAN DIEGO 92103 Job Name: DOT HILL-OFFICE,LAB TO OFFICE Job Address: 2200 FARADAY AV CBAD St: 100 INCOMPLE'i'E The item you have Mbmitted £,11eYiew is iHeomr,iete. Prt tltis time, tsis of§oo oaffll@t ndcetutttely eofteiuet a re•;iew te doteffliifto oeffl:flltEH½oo wifl.l fl.lo a1313lieaelo eodos and,lor s~andards. Please ro;v}ow emcfl:tHy aH eol'tlfllefl:ts attael'ted. Please festtemit ttle ftooossafy f)lElfts 8.ftdi1of Sf)eoifioatiee-s, wifl.l osangos "oloHElod", to ti.tis office fot 1cvicvv mid aw1uval. Conditions: Cond: CON0000754 This project has been reviewed and approved for the purposes of issuance of building permit. This approval is subject to field inspection and required test(s), notations hereon, conditions in correspondence and conformance with all applicable regulations. This approval shall not be held to permit or approve the violation of any law. CERTIFICATE OF COMPLIANCE (Part 1 of 2) ENV-1 PROJECT NAME DAT~/. i/ t>01' \-\\1.,l ... .. G'.f q OS PROJECT ADDRESS 2 '2-00 "FA\'Z-A:D~"-1 , CA'C-ll;.l;,Ai>1 CA q'2COf) PRINCIPAL DESIGNER-ENVELOPE TELEPHONE Building Pem1it # t>ONA,i..,r.;, r'!Tfvv',;t,..) (lotc:t)z~-ool\ DOCUMENTATION AUTHOR TELEPHONE Checked by/Date WAl-S!-t ~lfl,tr,.lEe ~t; ( toSB) 9-t I -0181} Enforcement . " GENERAL INFORMATION DATEOFPLANs cilcilDs I BUJLDING CONDITIONED FLOOR AREA I CLIMATE ZONE t' BUILDING TYPE B NONRESIDENTIAL 0 HIGH RISE RESIDENTIAL 0 HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION 0 NEW CONSTRUCTION 0 ADDITlON Jg{ ALTERATlON 0 UNCONDITIONED (file affidavit) METHOD OF ENVELOPE *=-0 COMPONENT 0 OVERALL ENVELOPE 0 PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. 1his certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE :{,. ~ r, nl / .A \ / q_ Sl-\AWN V-J\v;o~ Vl().Nvr ll'Vt.,,t'.,,; DATE q q ()t;' The Principal Envelope Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in sections 110, 116 throvgh 118, and 140, 142, 143 or 149 of Title 24, Part 6. Please check one: 0 I hereby -affirm that l am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or mechanical engineer, or I am a licensed architect. 0 I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. 0 I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. {These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) PRINClPAL ENVELOPE I SIGNATURE I DATE I LIC. # ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures Ml-I INSTRUCTIONS TO APPLICANT For Detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. ENV-1: Required on plans for all submittals. Part 2 may be incorporated in schedules on plans. ENV-2: Used for all submittals; choose appropriate form depending on method of envelope compliance. ENV-3: Optional. Use ff default U-factors are not used. Choose appropriate fom1 for assembly U-factorto be calculated. Nonresidential Compliance Forms August 2001 A)~ a:Jn·,f2..AC.TD-I' J N RJ '--f)ocs \ q/1a-Jo5 -r1J (._,J r'-t I p I !US I E::6&-1 L. LO I ~-e.r~ C..lt...-L.C..S 1/o1-,1 fo6' ~ & r"Ci,. z_ z3-ry;,-~;J C,L/1/ 0 ,~;;i.)<Y,; ~IL C....L., ('("', CB053199 2200 FARADAY AV CBAD St: 100 DOT HILL-OFFICE,LAB TO OFFICE LAB.56,204SF NEWWALLS,ELECT,MECH Tl INDUST Lot#: DONALD PITMAN -~ ------ ~ BUILDING PLANNING ENGINEERING FIRE APPR/FORM _______ HEALTH DEPT ------HAZMAT/MRQUAL ------OTHERSEWERDISTR TO FROM APPLICANT APPLICANT ____ ..,_ ___ SCHOOL FORM CFDFORM --n-.:nr-:-rlr::-::~"TTT"'7"f-:"'!:.,;;: E & MWORKSHEET ---,--'----,-,,.,.,..-,-.~BLDG FEES COMPLETE /o/;,c-do> i~ /h.w-/11 w~~ . I!~~ ~1 j; l',HIL -frcud ¼ 1IL to l:t ---l---+Ji~~LAN CORR ENG CORR -r-.,,,,-:::1"'-,_-ESGIL CORR __ __,_ __ ....... __ FIRE CORR ~JCJ-Fe_ ~T ¥,-~ · c..eP4t?u /J· \.. v \ '---I_ O"(" f.~ @fc__ r/Jr/t) pc;A