Loading...
HomeMy WebLinkAbout2205 CAMEO RD; ; CB050795; Permit05-27-2005 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB050795 Building Inspection Request Line (760) 602-2725 2205 CAMEO RD CBAD RESDNTL Sub Type: 1670804700 Lot #: $30,360.00 Construction Type: Reference #: 0 Structure Type: 0 Bathrooms: RICE RES- 276 SF ADD TO MASTER BEDROOM RAD 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check#: ISSUED 03/15/2005 LSM 05/27/2005 05/27/2005 Applicant: RICE RUSSELL&JOY 2205 CAMEO RD CARLSBAD CA 92008 Owner: RICE RUSSELL&JOY 2205 CAMEO RD CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $248.55 Meter Size $0.00 Add'l Reel. Water Con. Fee $161.56 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $3.04 PFF $0.00 PFF {CFD Fund) $0.00 License Tax $0.00 License Tax (CFD Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFD Fund) $0.00 Sidewalk Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Housing Impact Fee $0.00 Housing InLieu Fee Housing Credit Fee $0.00 Master Drainage Fee $0.00 Sewer Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $34.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $491.15 Total Fees: $491.15 Total Payments To Date: $161.56 Balance Due: BUILDING PLANS $329.59 IN STORAGE .ATTACHED Inspector: ?32i 05/27/05 1 02 „ FINAL APR Date:Clearance: NOTICE: Please take NOTICE thaty&pproval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." Yo/have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been aivenaNQTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 329.59 CITY OF CARLSBAD BUILDING DEPARTMENT1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLYPLAN CHECK NO. CAEST. VAL.Plan Ck. DepositValidatedDate /&? /CAAddress (include Bldg/Suite #)Business name (at this address).TT-JJ.-Legal Description Lot No. Subdivision Name/Number/<Unit No.Phase Total # of unjts.xisting Use Proposed UseDescription of Work SQ. FT.#of Stories # of Bedrooms # of BathroomsCONTACT PERSON (if different from applicant) Nam Address Cityy mjuiaaa i^ny ,- . . __ . . . J^: . __AEEtlCANT Q Contractor LJ Agent for Contractor QH Owner JJ Agent for Owner P .^r.ss & , . . <*l~,~.<~ s~^- ^ yftf C#r/sbAu( State/Zip Telephone #Fax # Address City /a* State/Zip Telephone # ?J**tt"' 76ff 7l1Sf7l- Address City State/Zip Telephone #Name B. CONTRACTOR - COMPANY NAME i - - - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]}. Name State License # Address License Class City State/Zip City Business License If Telephone # Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance the work for which this permit is issued. rj I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as become subject to the Workers' Compensation Laws of California. /ARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE ^?. . ^_.^)J^ \^ .-*-"/_ . DATE 3 ^ 'Og 7. OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: SB I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). CD I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. \ have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): DATE 3 • XVPROPERTY OWNER SIGNATURE CQMPLETEflf HIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONtY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? CD YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. (fcijl iCONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME A /,} /\x--< _ LENDER'S ADDRESS 1 certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or il the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days ,(Section 106.4.4 Uniform Building Code}. APPLICANT'S SIGNATURE ^7^.J\^ X K ~i Xt*. - . . DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 09/29/2005 Permit* CB050795 Title: RICE RES-276 SF ADD TO MASTER Description: BEDROOM Inspector Assignment: PY 2205 CAMEO RD Lot Type:RESDNTL Sub Type: RAD Job Address: Suite: Location: APPLICANT RICE RUSSELL&JOY Owner: RICE RUSSELL&JOY Remarks: Phone: 7607295072 Inspector: Total Time: CD Description 14 Frame/Steel/Bolting/Welding 18 Exterior Lath/Drywall 34 Rough Electric L £L Requested By: RICE RES. Entered By: CHRISTINE Act Comment AP /A tJr Associated PCRs/CVs Inspection History Date 08/24/2005 08/24/2005 08/23/2005 08/23/2005 08/23/2005 08/23/2005 06/24/2005 06/23/2005 06/23/2005 06/23/2005 06/22/2005 06722/2005 Description 14 83 13 14 15 24 11 11 21 24 21 24 Fram e/Steel/Bolting/Weld ing Roof Sheathing/Ext Shear Shear Panels/HD's Frame/Steel/Bolting/Welding Roof/Reroof Rough/Topout Ftg/Foundation/Piers Ftg/Foundation/Piers Underground/Under Floor Rough/Topout Underground/Under Floor Rough/Topout Act we AP CO we CO AP AP we AP we NR NR Insp PY PY PY PY PY PY PY PY PY PY PY PY Comments STRAP CORNERS, EXTEND SHEAR NAIL BLOCKS City of Carlsbad Bldg Inspection Request For: 04/25/2006 Permit# CB050795 Title: RICE RES- 276 SF ADD TO MASTER Description: BEDROOM Inspector Assignment: PY 2205 CAMEO RD Lot Type: RESDNTL Job Address: Suite: Location: APPLICANT RICE RUSSELL&JOY Owner: RICE RUSSELL&JOY Remarks: Sub Type: RAD Phone: 7607295072 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: RICE Entered By: JANEAN Act Comment Comments/Notices/Hold Associated PCRs/CVs Original PC# Inspection History Date 11/09/2005 10/24/2005 09/29/2005 09/29/2005 09/29/2005 09/29/2005 09/28/2005 09/28/2005 08/24/2005 08/24/2005 08/23/2005 08/23/2005 08/23/2005 Description 17 17 14 16 18 34 14 18 14 83 13 14 15 Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Welding Insulation Exterior Lath/Drywall Rough Electric Frame/Steel/Bolting/Welding Exterior Lath/Drywall Frame/Steel/Bolting/Welding Roof Sheathing/Ext Shear Shear Panels/HD's Frame/Steel/Bolting/Welding Roof/Reroof Act AP PA AP AP AP CO CO we we AP CO we CO Insp PY PY JM JM JM JM JM JM PY PY PY PY PY Comments OK TO TAPE CLOSET SUB PANEL NOT ALLOWED IN CLOSET ADD AB S TO INTERIOR SHEAR - ADD ON INSULATED STRAP CORNERS, EXTEND SHEAR NAIL BLOCKS 09/28/2085 16:58 8564549164 BENNETT AND ASSOC PAGE 01 From the Desk of Jan M. KM mas P.O. Box 8 , Valley Center, Ca 92082 (760) 533-96U Field Document Rice Remodel 2205 Cameo Road Carlsbad, Ca. Field Inspection: After review the interior shear wall configuration at the master bedroom closet area. The current shear wall installation is consistent with CBC Standards as approved by ESGUL Corp. during plan check review. Seo alternate braced wall notes per sheet A2.0 of approved construction documents. lectrully, W/ llimas - Consultant EsGil Corporation In (Partners dip witfi government for (Bui&fing Safety DATE: May 24, 2005 Q APPLICANT JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: 05-795 SET: IV PROJECT ADDRESS: 2205 Cameo Rd. PROJECT NAME: Rice Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: X] Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Bill Elizarraras Enclosures: Esgil Corporationn GA n MB n EJ n PC 5/16/05 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 EsGil Corporation In (Partners Hip vritfi government for Quitting Safety DATE: May 4, 2005 "' Q APPLICANT tf JURIS. JURISDICTION: Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO.: 05-795 SET: III PROJECT ADDRESS: 2205 Cameo Rd. PROJECT NAME: Rice Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies "identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X3 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Russell Rice 2205 Cameo Rd. Carlsbad, CA. 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. X] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Russell Rice (vM>|) Telephone #: 760-729-5072 Date contacted: s)v/^5(by: ^ ) Fax #: Mail ^Telephone-*•" Fax In Person REMARKS: By: Bill Elizarraras Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/26/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 Carlsbad 05-795 May 4, 2005 iRECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2205 Cameo Rd. DATE PLAN RECEIVED BY ESGIL CORPORATION: 4/26/05 REVIEWED BY: BUI Elizarraras PLAN CHECK NO.: 05-795 SET: III DATE RECHECK COMPLETED: May 4, 2005 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new complete sets of prints to: Esgil Corp. or to the bldg. dept. of the juris. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad 05-795 May 4, 2005 • The following corrections are from the original deficiency list, and were either not addressed or a result of new changes. • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Show the following on the plans for the required braced wall panels. If the requirements of braced wall panels in conventional light frame construction are not possible, provide design calculations from a licensed Engineer or Architect. Let-in 1x6 braces are not recognized in seismic zone 4, please use alternative applications. a) Show on the plans the location, length and type of braced wall panel as per UBC Section 2320.11.3 and Table 23-IV-C-1. i) Braced wall panels shall start at not more than 8' from each end of a braced wall line. ii) Braced wall lines shall be in line or offset from each other by not more than 4 feet. iii) braced wall panels in one story structures shall be installed at each end and not more than 25' on center along the length of the braced wall line. b) Interior braced wall panels shall extend to the roof or floor diaphragm level. c) Any braced wall panel required by Section 2320.11.3 may be replaced by an alternate braced wall panel. UBC Section 2320.11.4. For alternate braced wall panels in one story buildings, show compliance with the following on the plans: i) Minimum braced panel length is 2'-8" in width and a maximum height of 10'-0". ii) Each braced wall panel is sheathed on at least one face with 3/8" plywood sheathing nailed with 8d common or galvanized box nails per23-ll-B-1 and blocked at all plywood edges, iii) A minimum of two anchor bolts installed in accordance with Section1806.6 between hold down devices, iv) An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1,800 pounds is provided at each panel end. v) The foundation that supports the braced panels is continuous across the entire length of the braced wall line and reinforced with a minimum of one # 4 bar top and bottom. Carlsbad 05-795 May 4, 2005 4. For Conventional Light-Frame Construction, buildings shall be provided with exterior and interior braced wall lines. Spacing shall not exceed 25' on center in both directions. Sections 2320.4.2 and 2320.5.1 and Table 23-IV-C-1. 5. Detail shear transfer connections, including roof diaphragms, to shear walls. Section 2315. Please provide interior and oablo details as needed. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bill EHzarraras at Esgil Corporation. Thank you. EsGil Corporation In (Partners/Up witR government for (BuiCfing Safety DATE: April 19, 2005 a APPLICANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 05-795 SET: II PROJECT ADDRESS: 2205 Cameo Rd. PROJECT NAME: Rice Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Russell Rice 2205 Cameo Rd. Carlsbad, CA. 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. 2Sl Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Russell Rice Telephone #: 760-729-5072 Date contacted:f I *°il*5~(by. ^ ) Fax #: Mail L^felephone -^ Fax In Person REMARKS: By: Bill Elizarraras Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/12/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 4- Fax (858) 560-1576 Carlsbad 05-795 April 19, 2005 IRECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2205 Cameo Rd. DATE PLAN RECEIVED BY ESGIL CORPORATION: 4/12/05 REVIEWED BY: BUI Elizarraras PLAN CHECK NO.: 05-795 SET: II DATE RECHECK COMPLETED: April 19, 2005 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new complete sets of prints to: Esgil Corp. or to the bldg. dept. of the juris. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad 05-795 April 19, 2O05 • The following corrections are from the original deficiency list, and were either not addressed or a result of new changes. • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2, Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Show the following on the plans for the required braced wall panels. If the requirements of braced wall panels in conventional light frame construction are not possible, provide design calculations from a licensed Engineer or Architect. a) Show on the plans the location, length and type of braced wall panel as per UBC Section 2320.11.3 and Table 23-IV-C-1. i) Braced wall panels shall start at not more than 8' from each end of a braced wall line. ii) Braced wall lines shall be in line or offset from each other by not more than 4 feet, iii) braced wall panels in one story structures shall be installed at each end and not more than 25' on center along the length of the braced wall line. b) Interior braced wall panels shall extend to the roof or floor diaphragm level. c) Any braced wall panel required by Section 2320.11.3 may be replaced by an alternate braced wall panel. UBC Section 2320.11.4. For alternate braced wall panels in one story buildings, show compliance with the following on the plans: i) Minimum braced panel length is 2'~8" in width and a maximum height of 10'-0". ii) Each braced wall panel is sheathed on at least one face with 3/8" plywood sheathing nailed with 8d common or galvanized box nails per 23-II-B-1 and blocked at all plywood edges, iii) A minimum of two anchor bolts installed in accordance with Sectionl 806.6 between hold down devices, iv) An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1,800 pounds is provided at each panel end. v) The foundation that supports the braced panels is continuous across the entire length of the braced wall line and reinforced with a minimum of one # 4 bar top and bottom. Carlsbad 05-795 April 19, 2O05 4. For Conventional Light-Frame Construction, buildings shall be provided with exterior and interior braced wall lines. Spacing shall not exceed 25' on center in both directions. Sections 2320.4.2 and 2320.5.1 and Table 23-IV-C-1. 5. Detail shear transfer connections, including roof diaphragms, to shear walls. Section 2315. Please provide interior and gable details as needed. 6. Provide a positive connection between new addition and existing Dwelling @ top plates. Reference the detail form the appropriate location. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation. Thank you. EsGil Corporation In <Partnersnip -with government for Quitting Safety DATE: March 28, 2005 a AERUCANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 05-795 SET: I PROJECT ADDRESS: 2205 Cameo Rd. PROJECT NAME: Rice Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Russell Rice 2205 Cameo Rd. Carlsbad, CA. 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Russell Rice Telephone #: 760-729-5072 Date contacted: -i fz*f /o^(by: (A_ ) Fax #: ( Mail Telephone "* Fax In Person REMARKS: By: Bill Elizarraras Enclosures: Esgil Corporation D GA D MB D EJ D PC 3/17/05 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 Carlsbad 05-795 March 28, 2005 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 05-795 PROJECT ADDRESS: 2205 Cameo Rd. JURISDICTION: Carlsbad FLOOR AREA: 276 sq.ft. Dwelling Add'n STORIES: 1 HEIGHT: 16' REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: March 28, 2005 DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/17/05 PLAN REVIEWER: BUI Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad O5-795 March 28, 2005 • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4: a) Where the bottom exposed edge of the window glazing is less than 60 inches above a standing surface and drain inlet of tubs and drains. b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 4. Exterior doors may not swing out if stoop has an elevation drop exceeding 1". 5. The following anchor bolt requirements shall apply in Seismic Zones 3 and 4, per Section 1806.6.1: a) Plate washers (minimum size of 2" x 2" x 3/16") shall be used on each anchor bolt. 6. Show size, embedment and location of hold down anchors on foundation plan. Section 106.3.3. 7. Note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 108.5.2. 8. Show double top plate with minimum 48" lap splice. Section 2320.11.2. 9. Show nailing will be in compliance with Table 23-II-B-1. 10. For Conventional Light-Frame Construction, buildings shall be provided with exterior and interior braced wall lines. Spacing shall not exceed 25' on center in both directions in each story. Sections 2320.4.2 and 2320.5.1 and Table 23-lV- C-1. Carlsbad 05-795 March 28, 20O5 11. Show the following on the plans for the required braced wall panels. If the requirements of braced wall panels in conventional light frame construction are not possible, provide design calculations from a licensed Engineer or Architect. a) Show on the plans the location, length and type of braced wall panel as per UBC Section 2320.11.3 and Table 23-IV-C-1. i) Braced wall panels shall start at not more than 8' from each end of a braced wall line. Braced wall lines shall be in line or offset from each other by not more than 4 feet. braced wall panels in one story structures shall be installed at each end and not more than 25' on center along the length of the braced wall line. b) Interior braced wall panels shall extend to the roof or floor diaphragm level. c) Any braced wall panel required by Section 2320.11.3 may be replaced by an alternate braced wall panel. UBC Section 2320.11.4. For alternate braced wall panels in one story buildings, show compliance with the following on the plans: i) Minimum braced panel length is 2'-8" in width and a maximum height of 10'-0". ii) Each braced wall panel is sheathed on at least one face with 3/8" plywood sheathing nailed with 8d common or galvanized box nails per 23-II-B-1 and blocked at all plywood edges, iii) A minimum of two anchor bolts installed in accordance with Sectionl806.6 between hold down devices, iv) An approved hold down device fastened to the foundation and capable of providing an uplift capacity of not less than 1,800 pounds is provided at each panel end. v) The foundation that supports the braced panels is continuous across the entire length of the braced wall line and reinforced with a minimum of one # 4 bar top and bottom. 12. Detail shear transfer connections, including roof and floor diaphragms, to shear walls. Section 2315. 13. Provide a positive connection between new addition and existing Dwelling @ top plates. 14. Specify nail size and spacing for all shear walls and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. Sections 2315 and 2513. 15. Show location of attic access with a minimum size of 22"x30". Section 1505.1. 16. Specify plywood grade and panel span rating. Table 23-1I-E-1. Carlsbad 05-795 March 28, 2005 17. Note on the plans that receptacle outlet locations will comply with NEC Art. 210-52(a). 18. Per NEC Art. 210-11(c)3, note on the plans that bathroom circuiting shall be either: a) A 20 ampere circuit dedicated to each bathroom, or b) At least one 20 ampere circuit supplying only bathroom receptacle outlets. 19. All bedroom branch circuits now require arc fault protection. Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected." NEC Art. 210-12(b). 20. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. The regulations require a minimum of 9.25" cavity for the R-30 insulation with the 2x8 roof members you will only obtain a 7.25" cavity please provide alternative application. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation. Thank you. Carlsbad 05-795 March 28, 2005 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 05-795 PREPARED BY: BUI Elizarraras DATE: March 28, 2005 BUILDING ADDRESS: 2205 Cameo Rd. BUILDING OCCUPANCY: R3/U1 TYPE OF CONSTRUCTION: VN BUILDING PORTION Dwelling Add'n Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 276 cb Valuation Multiplier Per City Value By Ordinance Reg. Mod. VALUE ($) 30,360 30,360 $248.55 Plan Check Fee by Ordinance Type of Review: [~1 Repetitive FeeRepeats Complete Review D Other i Hourly Structural Only Hour* Esgll Plan Review Fee $161.56 $139.19 Comments: Sheet 1 of 1 macvalue.doc DATE: City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: CB fl £. BUILDING ADDRESS: PROJECT DESCRIPTION: 2^0 r"- ASSESSOR'S PARCEL NUMBER:EST. VALUE: ENGINEERING DEPARTMENT APPROVAL C- DENIAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: Please see the attached report of deficiencies marked with D. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. C- 3 By: By: By: Date: Date: Date: By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: Date: IMI [J U D n n ATTACHMENTS Dedication Application Dedication Checklist Improvement Application Improvement Checklist Neighborhood Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: KATHLEEN M. FARMER City of Carlsbad Address: 1635 Faraday Avenue. Carlsbad, CA 92008 Phone: (760) 602-2741 ____ CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: CA 92OO8-7314 • (76O) 6O2-272O - FAX (76O) BUILDING PLANCHECK CHECKLIST iST n n SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: orth Arrow X flight-of-Way Width & Adjacent Streets Existing & Proposed Structures / GL/Driveway widths Existing Street Improvements ' /t^L Existing or proposed sewer lateral Property Lines (show all dimension^N-: Existing or proposed water service Easements / ^ Existing or proposed irrigation service 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. F:\FarniertKalhy\MASTERS\BulkHng Plandwck CMM Form (Owwoc).doc Raw. 7/14/00 BUILDING PLANCHECK CHECKLIST 1ST D RD3 D DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. D D D 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 15.000 , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 W x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:Date: IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 75.000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the F \Farm8rtKalhyWASTERS\Bullding Planchack CUM Form BUILDING PLANCHECK CHECKLIST iST ND2 D ,RD n n n checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by:Date: 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the properly and processing fee of $ 360.00 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: D D D 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: CI 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. n n n n n GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export and remedial). This information must be included on the plans. 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by:Date: [H 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) F:\FamiBrtKalhy\MASTEHS\Building Rnnchack CU*t Form (Centric).doc BUILDING PLANCHECK CHECKLIST iST ,NO RD D D D D D 3 D D D 7d. No Grading Permit required. 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: D D D D D D D D INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 E! Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. 11. Q Retired fees are attached Q/No fees required WTER METER REVIEW 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. F-\F«rniertKHlhy\MASTERS\BuWdlnfl Planchwk CW«I Form (Gttwic}.doG BUILDING PLANCHECK CHECKLIST iST ,RD D D D • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA1+00 Install 2" service and 2. 3. 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water F:\Fami«rtK«thyWASTERS\BuHdfng Ptandncfc Cklel Forni <<3«noric).doc BUILDING PLANCHECK CHECKLIST -ST 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. D D D 12c. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D D D 13. Additional Comments: F:\Firm«rtK»lhyWASTERS\Buildinfl Rincheck ddil Form (Genaric).dac D D ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant. Calculation based on building plancheck plan submittal. Address:Bldg. Permit No. Prepared by:Date:Checked by:Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: • __ Sq. Ft./Units: Types of Use: Sq. Ft./Units: APT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq. Ft./Units: Types of Use:Sq. Ft./Units: EDU's: EDU's: ADT's: ADT's: FEES REQUIRED: WITHIN CFD: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1. PARK-IN-LIEU FEE FEE/UNIT: PARK AREA & #: X NO. UNITS:= $ D 2. TRAFFIC IMPACT FEE ADT's/UNITS: D 3. BRIDGE AND THOROU ADT's/UNITS: D 4. FACILITIES MANAGEt UNIT/SO.FT.: D 5. SEWER FEE EDU's: FEE/ADT:= $ JGHFARE FEE WENT FEE (DIST. X ZONE: X #1 DIST. #2 FEE/ADT: FEE/SQ.FT./UNIT: DIST. = $ #3 } $ X FEE/EDU: BENEFIT AREA: EDU's:X FEE/EDU: D 6. SEWER LATERAL ($2,500) D 7. DRAINAGE FEES PLDA_ ACRES: = *. = $ = $ HIGH /LOW FEE/AC:= $ D 8. POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION I of 2 RRV. 7/14/00 *ccv = fi 8 i i PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB 4f$-7fS-ArirtrPSfi Phone (760) 602- Net Project Density:. Facilities Management Zone: DU/AC CFD (In/out) #_Date of participation:.Remaining net dev acres;. Circle One (For non-residential development: Type of land used created by this permit: ! — ) Leoend^ IS Item Complete D Item Incomplete - Needs your action Environmental Review Required: YES NO j\ TYPE _ ; DATE OF COMPLETION: ' Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES NO X TYPE DATE OTHER RELATED CASES: . : : : Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: : __ Q Coastal Zone Assessment/Compliance / vXProject site located in Coastal Zone? YES NOA— CA Coastal Commission Authority? YES NCM If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): NOCoastal Permit Determination Form already completed? YES If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: ___ _ Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. Inclusionary Housing Fee required: YES _ NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES _ NO _ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: H:\ADMIN\eOUNTER\BWoPlnchkRevChkl8t Rsv9/01 rVr rn™ DD 1. Provide a fully dimensional site plan drawn to scale. Show:. North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including al! side and rear yard slopes). to r~| r] 2. Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES NO. 2. Project complies YES_ _ NO_ D D n DD Zoning: 1. Setbacks: Front: . Interior Side: Street Side: Rear: Top of slope: 2. Accessorwstructure Fro\t: / Interto^ide: Stre4\Side: aructjre separation 3. Lot Coverage: 4. Height: Required Required Required Required Required setbacks: Required Required Required Required : Required Required Required 2^>/ Shown fa 4* Shown _ " —r j Shown 1 4' &" Shown ^— Shown Shown Shown Shown Shown Shown &.LJOI ^ Shown ^ 20 Shown *2<f> G»'** •V 3^y. _— 5. Parking:Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required . Shown Comments : OrCTO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BWgPlnchkRevChklst Rev U01 \DDITION WORKSHEET Page 1 ADD Title .......... RICE RESIDENCE Date. . 02/26/05 12:38:143roject Address ........ 2205 CAMEO RD ******* CARLSBAD CA *v6.01* )ocumentation Author. . . ROCKY ******* Salehi & Salehi Inc. 8360 Clairemont Mesa Blvd, Ste 111 San Diego, CA 92111 858-277-5551 Ilimate Zone 07 lompliance Method MICROPAS6 v6.01 by Enercomp, Inc. Building Permit # Plan Check / Date Field Check/ Date MICROPAS6 v6.01 File-S238 Program-ADDITIONS User#-MP0406 User-Salehi & Salehi Inc. Run-S.F.R. ADDITION/ALTERATION WORKSHEET - COMPUTER PERFORMANCE EXISTING File Name S238 - S.F.R. Conditioned Floor Area 276 sf Standard Design Energy Use. 14.42 kBtu/sf-yr Proposed Design Energy Use. 14.08 kBtu/sf-yr NEW (EXISTING PLUS ADDITION/ALTERATION) File Name S238 - S.F.R. Conditioned Floor Area 276 sf Standard Design Energy Use. 14.42 kBtu/sf-yr Proposed Design Energy Use. 14.08 kBtu/sf-yr FLOOR AREA RATIO Floor Existing New Area Floor Area Floor Area Ratio 276 / 276 = 1.000 DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION/ALTERATION) Floor Addition/ New Area Existing Existing Alteration Standard Rat io Proposed Standard Des ign 14.42 + 1.000 X ( 0.00 - 0.00) = 14,42 Note: If (Existing Proposed - Existing Standard) is negative, this difference is set to zero. ADDITION/ALTERATION ENERGY USE SUMMARY Addition/ Energy Use Alteration Proposed Compliance (kBtu/sf-yr) Design Design Margin New 14.42 14.08 0.34 *** Addition/Alteration complies with Computer Performance *** Q:o LLJ 3 COu <o=&*0 8°19C ! co CN , w. LUCC 3LU n m 9 co^ ~)o:^ LU Oo: CC Q -S !=^ LU LUo o: CD cc «D ^tv\