Loading...
HomeMy WebLinkAbout2237 Levante St; ; 85-679; Permitt I V, z 0 ;:: "' .. :l u "' 0 .. il u .. "' 0 ~ 5 .. ii: "' z ~ O I hereby alflrm that I am licensed under provisions of Chapter 9 (commencing wrth Section 7000) of Division 3 of the Business and Professions Code, and my license is 1n full force and ellect Lie No ______ Cla•< I ~ereoy a·'irrn In;;• I t:rs lrcerse ,a·;, io, Bus•ness ac.~ P:ofe<:s Qnl ~uires d per~·· ·epa,· cny structure ,,1,can' •o, son 1:e1sec pu•,ua1· ·c L sense Law ·Cha:i·w co"lmenn~g w C".-srao -'l r,' the B,s,1ess and p,ofess-~ns err~I •oe,elr~r,, and The Cas,s hr the al eged e•,,rnpt,on ,,,n·dt 0n c' Se:;t1c1 7031 ', oy an JP811Pnt 'c· a :iwn 11 eels rre a:i8·1ccn1 to a;,•,, r;enait1· ol not "l:ire Thdn •,,,e 1Jr ared dGI ars i$50C" .is :,wner ci r~e prope·t·1 or rri, ems,lo1ees ·w,·r ,'/age\ ~.s 1re1-sole co,.,oensaMn w111 de the ·;,or• 'h~ 0,trcc lure .1 -01 ,nlended or o'ter~d lor sale 1S~c Bus ntss anc Pro'ess o~s Coce ~re Conr·acio-s L1cP-nse L3;,· C•Jes no' dP~ly ,~ dn Jwner at prope'ty wro 0,,1,as or 1,,,r,,oves theresn anC wro does such wO'k ~1mself G" t~roug~ h1~ ow1 emc!oyees. Jrov1Ced !~at sue~ 1m~rovemen:1 .ire no! 1n1e1d ea o· ,;lle•ec for sa·e 11 however rne bu1id,ng or 1rPprove 11,e1,l 1> ,u·,u wi'L11,i: une year or cornp1e11on 1ne owrer-bu1•cer wdl have the Durcen of ~roving that he did ~ot build or "'7 vo·,e for 1~e ~·Jrpose of sJ!el as owner ol the pro~efly am e,clus1ve1y ccntrJcJ1ng w1Jh l1cen<ed ccr.1rac1wo to construct The pro1ec! !Sec 70.:4 B~s1~e,s anc Pro!ess101s Code The Contrdclo' s l 1ce~,e Law does not apoly to an owner o' p·ooerty who bu1 as o· 101- p·oves :nereon and w~o con:•acts f8r each pro!ecls w1t1 a contractor(sl 11cense pursuanl :o the Contract8r's 11cense Law1 As a homeowne· I am 1mp,ov ng m·1 heme and the 'o lcw 1ng cond1i1ons exist 1 The wo-k ,s being pertor•ned prio' to sa e 2 "ave lived 1r m·1 home fJr twel,·e nontns prior to completion of lh10 ,'/Ork I have not cia1meo l~1s exemption durinq 11e 1as1 trree years L I am exempt unae1 Sec ior ,n1s reason ____________ _ B & PC II "' .. "' 0 u V, "' "' " .. 0 ,. I hereb) a!f;rm Thal I nave a cer11f1ca1e ot -~onsent to s~:1 1nsve. er a certificate Jf \',Orfccrs' Comoensat1on In su-ance or a ce·:11 ed copy 1he·eof 1sec 380C Labor Code! POL,CY l'.0 COMPANY c~~-y 1s 'leu ,. to tne c,ty Ce•11f ed copy 1s nereby furnished CERTIFICATE OF EXEMPTION FROM WORKERS COMPENSATION INSURANCE 1Th1s sec1,on need not be completed d the permit 1s for one hund-eC dollars ,$7001 or :essJ __ I ce,t,fy that 1n the perlormance ol the work fo· v,h1ch ;his oerl°r'11 ,s issued. I shall not employ any person 1n any ,ra~ner so as to become sub1ect to the Workers· Compen sat1on Laws of Cal1forn1a NOTICE TO APPLICANT. If, after making this Certlf,cate of E,emptmn. you should become sub1ect to tne Wor~ers Compensation provis,ons of the Labor Code. you musl lorthw1tt1 comply with such provisions or lh1s perm1I s~all De deemed reso~ed [ C ' ""' """ '"' "'" ' " """"" """ ffi agency-for tne performance of the work for wh1cn this per C m1t 1s issued (Sec. 3097. C1v1I Code1 z W Lenders Name ___ ~ Lender s Aadress USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. CARLSBAD BUILDING DEPARTMENT Carlsbad. California 92008-1989 (619) 438-5525 APPLICATION & PERMIT DATE OF APPLICATION BUSINESS LICENSE # VALUATION PERMIT NUMBER ':~:;~ 7 / ;;i ~ 3 Ci LAV. ST. AD. rEAREST CROSS ST euo.-.:::::t-e. ~✓.111/FR d.<.::.1,5~0 L _];:, suso1v1s10~..5I ASSESSORPARCELN~, ~a§=s ~\ S L.. <:'... b~ ..2._ I (,,, -.;>. <+ 0 · COT BLOCK CONTRACTOR . ZONE l.:,/1;"'; ,-i~ p/qr CONTRACTORS PHONE • <}3_/-/J6,6_ s~-67 q .... -- 0:,,~;;'ei; 720 za tra ka}(]toylCJ3Lw~'i1'"i3 , I,,.., se::i CON°rRACTQA'S ADO(f'SS . LICENSE NO. PLAN 1.0. " BUILDING SQ FOOTAGE OWNER'S MAILING'ADbAESS , !-1:_,;i.o-u 1 £6' o//-llc/ e,,rr1a O Sf DES~NEA , , DES~NER'S .. PHDNE-- ' DESCR"»ON °' WORK t n e, 'J>4 rttl 11 l 765~f::, OO!:J DESIGNER'S ADDRESS LICENSE NO . ///0/f:!6%I~ ,.., , .. OUOl 9615 I/ I □-/ 86 , ~7~M~,, I --~~ ,, SCR,CEV NO occG, EDU I STORi ES I ,C s:J ~ ~2_1) ,;)_ cu,sus ~nACT l_ANO u':>E F-AH1<.1NG '.c,>'ALt GRADING PERMIT ISSUEC RE:OEVELOP....,ENT DCC LOAD FIRE SPP A REA , D N . C ,.., v D Nor Valid Un/en M•chine Cert1l1ed I QTY I MECHANICAL PERMIT. ISSUE -SUMMARY/ACCOUNT NUMBER I 1 ~4'=c'."_"''"c=--'-'=<-;:..,<'1'-_o__~cc""" INSTALL FURN DUCTSUPT0100000BT@ : ____ __ ~ --+---+-OVER 100,000 BTU BUILDING PERMIT boTI10-06Wa220 SIGN PERMIT 001-810-00-00-8221 t---C'" - I I I I I I I I I I I I I I I I EACH WAT_EH HE.ATER ANU O~_pl_.50 -1 BOILER.CUMPRESS □H.UP T □ .. J HP lt,/--'l+-''-'=A-_cCc-_H .. Gc'.cA~~s1 ~M 1 I_~_'.:_ UUTLLT~~. -: --l ROIL~R~C?~~~E~SOR ~ 1_~ HP __ _ f------1-E_ACH GAS SYSTEMS DR MOR~ ---• ___ ~-',H'IAL "IR~_PLA~~-~-_ EACHINSTA~ ALrER.HEPAIRl'.'AlE.RP1PE d· -~ · vEN~!ANS1NG~cT(!_,~ ~ EACH VACUUM BREAKE s::. _ t MECH EX HAUS I HOOD lJUCTS -----f----~ --:r::__-:-~ ~--·0- PLAN CHECK TOTAL PLUMBING f------CL!:.CIR:CAL MECHANICAL +-----~--lt--~~!LEHDME 001-810-00-Q0-8806 S -l -~ 001·8100000-8222 . ~:== 001-810-00-00-8223 5 - 001-81 0-00-00-8224 001-810-00-00-8225 ~ - _+WA.TEA S .. OFTNEH ____ -=-1==.:-------i--...;-□CATION OF f:A FURNACE H~ER MOBILEHOME PARK INSP --t1 f,\C'1 ;i::,.''.r: ><,\I'-. 1·:~~ ;r: __ ___ _ ~ .:J._-· -SOLAR 001-810-00-00-8226 . 'I STRONG MOTION 880-519-92-33 f------·----,---. IS.~\ JO l A I PLLJMBI~(. I _ --------~E_ ~PRINKLERS 001-810-00-00·82[£27 I ef. ' PUBLIC FACI_LITIES FEE 332-810·00·00-89~ _ ___ _ QTY ELECTRICAL PERMIT_ ISSUE ., ~ _ ·'1 OTY SOLAR -ISSUE 1 ;.'1...~;cI'~~GW---40D - NEW CONST EA A'-'lP SWl f:JK ll'.20~ CCJl I ccrnr:is ------SCHOOL FEE -DISTR1~q_j.ejl-~ - I PH l PH ---~ s I ORAGt._Tl_,,_,_s --------lbt¼~ll'~~~.._.,.-'-'"r --Cacl_sb_,d --+----------~ '- HIST BLDG EA AMP SWT 8KR I ROCK s~oRA-:;F ---------r---Encinitas !PH ]PH. 4· _ _____.:__ P1JMP -------------1ttt-t1-~-<>--t"tll-!"l--il __ SanD1egu1to L.-C~ -7·-- REMOnEL ALTtH PFR CIRCUIT ____ PIM.-C~LCK r:[E _ ____ _ _____ _ 1--8 PP01E20UAMPS ---_-___ ------ OVER 200 AMPS · --=-=====:Joi~~~~~:!l~~~~t~~i~ ---,.;;2,DI ---- llMPOCCUPANCY1.)0UAYS! ---~ ------!!---+---_ jf----:'~ ..---, -~~-' --'--------·--,.-~---__:___,; --------+---.,11--=-==--=:...:....:'-"-'-------,--r 5;:J:s.;:,.r. 117TAL !.lt.l.TRif.At !, I 'OTM SOLAr:l TOT AL FEES PAYABLE 101-11 I /n.750,8\ Expiration. Every permit issued by the Bu,ldmg Off1c1al under the prov1s1ons of this Code shaJ! expire by !imitation and become null and void If the building or work authonzed by such permit 1s not commenced within 180 days from the dale ot such permit, or 1f the btiilding or work authorized by such per is suspended or abandoned at any time aft.!!" the wor_k_ 1s ommenced for 1od of 180 da s * AN OSHA PERMIT IS REOUIAEO FOR EXCAVATIONS OVER s· O"' DEEP ANO DEMOLITK>N OR CONSTRUCTION OF STRUCTURES OVi:R 3 STORIES IN HEIGHT APPROVED BY DATE .I I I I HAVE CAAEFULL Y EXAMINED THE COMPLETED ··APPLICATION AND PERMIT"' AND DO HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE DECLARATIONS ARE TRUE AND CORRECT ANO I FURTHER CERTIFY AND AGREE IF A PERMIT IS ISSUED. TO COMPLY WITH ALL C!TY. COUNlY ANO STATE LAWS GOVERNING BUILDING CON- STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All UABlUTIES. JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT ~j~~Ni\ CONTRACTOR 0 BY PHONE~ L\ . o._ ~.2),-0 J iJq Is <e.. w u.. ~ ~ 0 0. E ~ 1-- D 'o ('.) l'JLBP m 0 0. 0. ., I 1 C 0:: 0 ~ ~ © ~ ~ ., ~ .2 © >- "" ~ © 0 0 ct "' "iii 0 £2 w 0 C "' C Li: - C w ~ ('.) a ;:; m 0. ~ C m ~ ,:: TYPE I DATE INSPECTOR BUILDING I FOUNDATION -:-....... " . REINFORCED STEEL /) ' ' JIJArl T If'. M.ASOt>IB¥., _, • -1/z..7 ..,f../ ; I GUNITE OR GROUT ' I I SUB FRAME □ FLOOR □ CEILdNG /l SHEATHING □ ROOF □ SH~AR 3/4/y~ i"7""'/l FRAME I ' > I ••/y,i 17 EXTERIOR LATH I \_ , I /') INSULATION I \ ..;, ·;.,.Jr, IT - INTERIOR LATH & DRYWALL I \, "/ r--:r' ' ~,.._/.,~ . I PLUMBING I /l ., SEWER AND BL/CO PUCO /1'4/P~ 17'-;::'. UNDERGROUND □ WASTE □ WATER /#J;/r~ "Ml TOP OUT □ WASTE C Vi/ATER q/14/yt, -r- TUB AND SHOWER PAN I f I -GAS TEST I 4//6/(6 r □ WATER HEATER □ SOLAR Wl\TER I < ' I ELECTRICAL ' •. □ ELECTRIC UNDERGROUND □;uFFER /J ROUGH ELECTRIC I qf;-1/r• 1/ /) --~ . □ ELECTRIC SERVICE ~TEMPOR.crRY ~/4.' 1., / .. □ BONDING □ POOL ' , . I I MECHANICAL I II □ DUCT & PLEM., □ REF. PIPlr,,JG /1-/JI/Y{ CT- HEAT -AIR COND. SYSTEMS I I I . VENTILATING SYSTEMS ' I CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HA VE BEEN APPROVED. FINAL ' I PLUMBING "-I ELECTRICAL "' I /J MECHANICAL " ; I ', --'{ . GAS "'l I 'C.1.L ,,,. __ I ./ BUILDING I "" ['/ . SPECIAL CONDITIONS ' I ' ' FIELD INSPECTION RECORD REQUIRED SPECIAL INSPECTIONS INSPECTION' SOILS COMPL IAN~-r PPIOR TO REO 1r-: j.lNSPECTOR S CHECKE~ APPROVAL INSPECTOR'S NOTES DATE FCL;NOA l,Or-.. i".SF ----l STPLJCTl,1riA1_ ~~c1'-.i:~RFTE: I f~---·,-,·•.· I . I .. ,. . .' .,,,,, ""' . -+--;;;, . ,:,~ f''':"~! .... ?}J _; ,,· ." CJVER ;>:~,(:Ci P\;I PRESTf~ESSEr.~ (:()NC:RETf-_ l ., $?' 5 ~ <,,7'1 CONCRETE ~-+'~+'-+J,;:;._~, ~'41· ------------:--;----:--------f-----------+----+------• , ' r, t. , t. -, ·, -· ... · ,.. POST TEN;1QNC[) I t=i 1 · -... ' . ' FIE~D Wf:LDlr-..JG Hll~rl ST9t.N\JTH- 8()L Ts :;~'E'C1Al_ .',,1AS'.)'..RY- -i----+ ----. : t" ' ·~ " r-----------------1------->-- ;==-E;_-;A':.:f_" . ·'±_ _ [ ~-. •~ . ! < I '" I +----~-t t --- --+------+----- r----- --- ------+-----------4------, >------------+-------+-----+-------j - .,. 7 I---------+----+---+-------, r--------------~--·-1 .________ ______ ---------------1.--------' I ~ I \ FINAL BUILDING INSPECTION PLAN CHECK NUMBER: DATE: _!]_.___-_\.__l]_.__-....,._8.....,.,./o'--- PROJECT NAME: ~! J P \ c? X ADDRESS: _ _...fl--""'9'-'S""---L7_-__,,cR"---"""'&2 ........ \ 9,L.__J.9:...__r::,_L,_,_e....,"1'-LL,Q.f.-L.i.._c::...._ ____________ _ PROJECT NO.: _______ UNIT NUMBER: _______ PHASE NO.: ______ _ TYPE OF UNIT: ------------NUMBER OF UNITS: CONTACT PERSON:_--',___._.L.L...,._,,~------------------------ CONTACT TELEPHONE: 9 2) I -18 /g 2. ~y~PECT;J>~½J DATE ½ /,11, INSPECTED: 7 J 3 7 APPROVED X DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED A.'\ lkPl-5 ~o< \ f\~ Pec.+,~otA- COMMENTS: ~l \ UeP Rev. 1186 WHITE: Suspens~ CANARY: Utilities PINK: Planning GOLD: Fire FINAL BUILDING INSPECTION PLAN CHECK NUMBER: DATE: PROJECT NAME: --c,,) ).,___,.__._f-.__-'-"------------------------- ADDRESS: c{ ~.:1 7-.212.:14 Le ih ,1 ./.<c PROJECT NO.: _______ UNIT NUMBER: _______ PHASE NO.: ______ _ TYPE OF UNIT: ____________ NUMBER OF UNITS: ;__ CONTACT PERSON: ________________________________ _ CONTACT TELEPHONE: ct :O I -l c3 lo 2.... INSPECTED BY: _________ _ INSPECTED BY: _________ _ DATE 7 I-. I 1 / INSPECTED: ~ DATE INSPECTED: DATE INSPECTED: J\'\\)epl5 APPROVED w DISAPPROVED __ APPROVED __ DISAPPROVED __ APPROVED __ DISAPPROVE +o <" \ f\ J Pee.. ~/OJ"- COMMENTS: ----------=~~~-::-1L...:\=-------=u==--=-e._._e~--=----------- Rev. 1/86 ;-. _.,, -----:..----· ,., ... ;-·,• .. ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (61 V) 560· 1468 DATE: , /fr!J(Lf'r-l<Y {; 1/,r{, QAPPL ICANT a_JURISDICTION D PLAN CHECKER 0 FILE COPY OUPS JURISDICTION: C,, !TY Q,t= C.8 R1-$ 51;,0 PLAN CHECK NO: D DESIGNER PROJECT ADDRESS: < ..... _.., / PROJECT NAME: • □ □ □ D □ □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdi ction 's building codes . The plans transmitted herewith will substantially comply with the jurisdiction 's buil ding codes when minor deficien- cies identified _______________ are resolved and checked by building department staff. The plans transmitte d herewith have significant deficiencies identified on the encl osed check l ist and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction 's copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for r echeck . The applicant 's copy of the check list is enclosed f or the jurisdiction t o return to the applicant contact person. The applicant 's copy of the check lis t has been sent to: Esgil staff did not advise the applicant contact person that plan check has been comple t e d. Esgil sta ff did advise applicant t hat the p l a n c heck has been compl e ted. Person contacted: £A>DR.E P)PR.TIIN I// Date contacted: /·?·¥~ ~--'----"-....a.....----Telephone # 1SS-le uOS REMARKS: _________________________ _ -------------------------·------- ..__,,! • 1 t<l:t_d! BY: _,,..,, /11 lkl1 _.1,1.,V. V ESGIL CORPORATION ENCL:_~N~O~~~€ ____ _ I -ft,· i'- ESGIL CORPORATION 9320 CHESAPEAKE DR .. SUITE 208 SAN DIEGO , C .-\ 92 J 23 ( H I !>) .3<i0· I 4(S8 DATE: □APPLICANT JURISDICTION : c, rr r aF c.eR1-:. Bc1J '6lJ JURISDICTION D PLAN CHECKER D FILE COPY QUPS PLAN CHECK NO: D DESIGNER PROJECT ADDRESS: PROJECT NA~!E : □ D ■ □ • □ □ • The plans trans mitted herewith have been corrected where necess~ry a nd substantial l y ccm2ly with the jurisdiction 's building codes . The plans transmitted herewith will substantially comply with the jurisdiction 's building codes when minor deficien- cies identifie d _______________ are resolved and checked by building departme nt staff . The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction 's copy for your information. The plans are being held at Esgil Corp. until corre cte d plans are submitted for recheck. The applicant 's copy of the check list is enclosed for the j urisdiction to return to the applicant contact person. The applicant 's copy of the check list has been sent to : Esgil staff did not advise the applicant contact person that p l an check has been completed. Esgil sta ff did advise applicant that the p l an check has been completed. Person contacted: E N DeE A Ag TfHtJ'II Date contacte d : ;-;;..-I?ro Tele phone # ?-55-&,op.S REMARKS : __________________________ _ BY: ~L1cJ lJcid-h./ ESGIL CORPORATION ENCL : .ST( /!'ATIJJG..s I :i../ ;;;o/~5'" --; .... I I I I I JURISDICTION: (2,,e,e LS 6 AQ Enclosures: ..STC.. R'P-1l•Viz,5 .:;CJ-=~ n'· DATB / -,;i_ -~" PROJECT ADDRESS: ;.__-::;-') /l (J-1 s -r To: soce ==-fjPR:Ti4/fJt1 /,!; .1 c:i s -.e e-r: ::: t ·-- Date plans received by jurisdiction J/1;(/~:i" Date plans received by plan checker;i/4w/J'_., Date initial plan check completed /pi.?£ by g ,tv. 7 I FORWARD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections .based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The items circled below need clarification, modification or change. All circled items have to be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Q,,aeu;;.eeo /?i LC,;,. ag-er; To facilitate rechecking, please identify, next to each circled item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans. PLAN CHEC!t NO: 8s-6 7 9 zr 0 APPLICANT COPY 0 JURISDICTION COPY 0 PLAN CHECKER COPY D FILE COPY 41784 , ESGIL CORPORATION 9320 CIIESAl'E.\KE DR .. SUITE 208 SAN DIEGO, CA 92123 (619) 560· 1-"1;8 DATE: NOU€.m6ER... ¢6 I l'tf5 QAPPLICANT JURISDICTION: jg! JURISDICTION D PLAN CHECKER D FILE COPY QUPS QDESIGNER PLAN CHECK NO: PROJECT ADDRESS: L£ll/'WTc sr. PROJECT NAME: 2 5TD(? '{ Qu .. fLe X □ □ • □ ■ □ • □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified-,----:----,--~-,-=-=-----are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's c~py of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone# _________ _ REMARKS: _________________________ _ BY: d,,:lu,..,.; Wa)J,,., I ESGIL CORPORATION , ,-, ~-f'S" _________ , ENCL: OF;tJ. ,";,FP. s ,,,,..:T 57"C .5 f&C5. ~"' ~---~-· .... '"---:""""· --·._· ._-., PLAll aimc IK>. 8.:5' -(,, J 9 JORISDICIIOII: 4,. (tfcLS e,ft 0 m, ✓a:.e:et+ K/4:fb.r:t& cflS'7 9 J.,1Lc, t f & N ti: DLlll'llllll! .,_ ------------ sr, . c., ey ;; /..IE V/1:»Te .ST Date plans received by jurisdiction: Date plans received by Esgil Corporation: Date initial plan check completed: Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1982 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. PIAlfS f· Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corp., 9320 Chesapeake Drive, Suite #208, San Diego, califomia 92123, (619) 560-1468. G) Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction1s building department. 0 To facilitate rechecking, please identify, next to each listed item, the sheet of the plans upon which each correction has been made and return this check sheet with the revised plans. ,j. On the title sheet, indicate on plans the name of the legal owner and name of person responsible for the preparation of the plans. -----·---,f.-·-· /.· Plans, specifications and calculations shall be signed by a California state licensed engineer or architect. (California Business and Professions Code). 0 Specify on the title sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. (;':) Provide a statement on the title sheet of ~ plans that this project shall comply with the editions of the codes as adopted by the jurisdiction and listed on the attached supplement sheet. SEif 1 R, f. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes and approximate finish floor elevations for all structures and show elevations at all lot comers. Section 302 (a) 7. -,. Indicate distance from center-line of ~treet or alley to property line and distance from property lines to proposed building. Section 302 (a) 7. B. FIRI! P!IOtliCIIUII 1.0. Walls closer than 3 feet to property lines 'hall be one-hour rated construction, have no openings, and shall have 30 inch parapets when the building floor area exceeds 1,000 square feet on any floor. (Table 5-A, Section 1709 (a) ). f.: Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 1710 and Section 504 (a) and (b). y.. Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of non-combustible material if they project into the 3' setback area from the property line. Section 1710. @ Show location of permanently wired smoke detectors. Section 1210. 51:e J!!, K.. 'J/. A smoke detector shall be installed in the basement of dwelling units having a stairway which opens from the basement into the dwelling. Such detector shall be connected to a sounding device or other detector to provide an alarm which will be audible in the sleeping area. Section 1210. C. RIUI SIZES, LIGHJ:, Yl!IIIIL\rIOII AND GLAZIIIG p. Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. Section 1207. (b). ;/,. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a). Appears to be deficient in -/,. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms, minimum is 1.5 sq. ft. (Section 1205 (a) ). ___________ _ Gv At least 1/2 of the c0111110n wall must be open and have an opening not less than 25 sq. ft. if light and ventilation is being supplied from an adjacent room. Section 1205 (a). s,;e uffl 1/• Required windows shall not open into a roofed porch unless the ceiling is at least 7 feet and the longer side is at least 65% open. Section 1205 (a), ---------~i..---- Gv-Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, lawtdry tQQ!H. and similar rooms if required windows are not provided. Section 1205 (a). '/1. No habitable room, other than a kitchen, shall be less than 7'011 in any dimension. Section 1207 (c). /2 Show that ceiling height for habitable ro;ms is a minimum of 7 1611• Section 1207 (a). Z1. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7 1011• Section 1207 (a). /.. Provide 3011 clear width for water closet compartments and 2411 clearance in front of water closet. Section 511 (a). @ Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Section 5406 • .;/.t,,6D M-1 11Ce1'1r 1'0 i;.Mt. ~ PC(){l. Q Glazing in shower and tub @OClO§..tg_~~---~.Mil Ye tempered' lam\Mted OL.film~QY~Jl.ru.3.§_t;.jc (including windows within 5 feet of tub or shower floor). Section 5406 (d). yf. Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 4411 above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 2011 and the minimum openable height 2411 • Section 1204. '16• A mezzanine is an intermediate floor and may not have a floor area exceeding 33 1/3 percent of the total floor area in the room below, arid the mezzanine floor must have a clear height of 7 feet, above and below and must have the long side open to the room below except for posts and protective walls railings not exceeding 4211 in height. 1716. or Section r__· The loft you show does not comply as a mezzanine floor and is, by Uniform Building Code definition, a story. D. liXI7S, SL\ll!IIAYS, AND RAU.!]!e ~-Floors above the second story shall have not less than 2 exits. Section 3303 (a). ¥-· Required exit doorways shall be not less than 3611 in width and not less than 6'811 in height, and shall be capable of opening at least 90 degrees. Section 3304 (e). 3/. Provide 3611 high protective railing for ~orches, balconies, and open sides of landings. Maxi.mum opening between railings shall be less than 611 • Section 1711. ~ Show how guardrail coMection details are Vequate to support 20 pounds per lineal foot at a riaht angle to the top rail. Table 23-B. SI/OW d541Al€cnaAl5 OIi Dl!TI'flL .S/.D.J.. f · Provide stairway and landing details. Section 3306 (b) & (c). a. Maximwn rise 811 and minimum run is 9". b. Minimum headroom is 6 1 6". c. Minimum width is 3011 • @ All handrails shall satisfy the following: /. Provide handrail for stairways with 4 or more risers. 0 f Handrail shall be 30" to 3411 above the nosing of treads. OETFt1 LSI D~ APPsfliS Tl> e,e .:z ".l .•• The hand grip portion of handrail shall be not less than 1 1/411 nor more than 2" in cross-sectional dimension. Section 3306 (j), (see attached). f · Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairway width. Section 3306 (g). I• A door may open over a stairway landing provided the door, in any position, does not reduce the clear area of the landing in the direction of stairway travel, to less than one- half the required width of the stairway. Section 3306 (g). 3/3· A door may open inward at the top step of a stairway provided the top step is not more than 7 1/211 · lower than the floor level. Section 3304 (h). 'f· Provide details of winding stairway. a. Minimum tread is 6 inches at any point and minimwn 9 inches at a point 12 inches from the side of the stairway. b. Maximum rise is 9 inches. c. Minimum width is 30 inches. Section 3306 (d). 4/'· Provide spiral stairway details: a. Minimum run is 7 1/2 inches at a point from where the tread is the narrowest. b. Maximum rise is 9 1/ 2 inches. c. Minimum headroom is 6 feet 6 inches. Section 3306 (f). 4/. Spiral stairways may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). 4/. Spiral stairways must have a clear walking space of 26 inches between the column and handrail. Section 3306 (f). . -<· t· Provide I.C.B.O. Research Report and Number for metal stairway, or submit plans and calculations and approved fabricator registered with the Building Department or note that the stairway fabrication shall be done under special inspection per the approved fabrication plans. Section 306 (a) 4B and Section 306 (f). ~-In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stairway. An exit balcony with 2 separated stair,.,ays is exempt. Section 3306 (1). i/s. Exterior stairways shall not project into the 3 foot setback from the property lines. Section 3306 (n). e. The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). C.f»il·T l:.l.l)~Efi'. E. ROOFING ,;. Specify roof pitch. ;'-Roof pitch is not adequate for roof type specified. Specify minimum pitch of ____ _ C\. SpecifY.,_roof material and a~plication. v::y 7 'I~ OP-UN/)b7U./li'l1/~IJT, :;{>. Specify I.C.B.O. or U.L. approval number for roof materials not covered in U.B.C., e.g., tile, etc. i. Specify that wood shakes are pressure freated Class C (when required by Jurisdiction Ordinance). Provide I.C.B.O. number. @ Specify that the roof system shall be fire retardant complying with Section 3203 (e). sJ. Specify roof slope for drainage or design lo support accumulated water. Section 3207 (a). 1/4" per ft. min. pitch per Section 2511 (d) 6. 'j,'('. Show roof drains and overflows. Section 1207. ¥3. Provide skylight details to show compliance with Sections 3401 and 5207 or provide r.c.B.O. approval number (4' min. between plastic skylights). Q Show attic ventilation. Minimum vent area Ys 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above ceiling joists. Section 3205 (c). F. IIASOIIRY r._ Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Section 3707. ~-Show veneer support and connections comply with Section 3002, 4, S, 6, and Section 2515 (a) regarding ties and #9 wire in horizontal joints or note construction to be per attached sheets 30-1 or 30-2. s/-Show height and construction details of all masonry walls. Chapter 24. 6/. Note that cleanout openings shall be provided at the bottom of all cells to be grout filled over 41 in a single pour. Cleanout shall be sealed before grouting, after inspection. Section 2415. fl. Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Section 2310. 6',. Show how masonry house walls retaining 'arth are to be waterproofed. Provide detail. · 6x'°. Show a minimum 211 air space and flashing "~ween planter and building walls. Section 2517 (e). G. GA1Wi1! AND CARPORIS ® Garage requires one-hour fire protection on the garage side of walls and ceiling coDIDOn to the ~ing. Table 5-B, Section 503 (b). Nor E 15 ,4 T LIIIJ NOii!. r HiXJ SE /,.)/Hu •• /s· All e ements supporting floor above garage including walls supporting floor joists, to have one-hour fire-resistive protection on the garage side. Section 503. Beams and posts, not within the wall or ceiling construction, must comply with UBC, Table 43-A, or be minimum 611 wide by 1011 depth beam and minimum 811 by 811 post. ~ Show 1 3/811 solid core self-closing door ¥r openings between garage and dwelling. Section 503 ( d). o/-Garages are not permitted to open into a room used for sleeping purposes. Section 1104. ,js. Openings between carport and residence require self-closing doors and stationary windows. Section 1214. ✓-Show garage framing section, size of header over garage opening, lateral cross bracing at plate line, method of bracing garage front, and holddowns when required. Chapter 23. NOTE: Minimum plywood diaphragm ratio is 3 1/2 to 1. Table 25-I. I Doors may open into the garage only if the floor or landing in the garage is not more than 1/2" lower than the door threshold. -/1. Provide 1811 raised platforms for any FAU, water heater, or any other device in the garage which may generate a flame or spark. --------~---· i I B. fflJIIDATIDN RIIX)ulki!HENIS 'J1-• Note on plans that "A soils engineer shall evaluate any wianticipated uncompacted fill or expansive soil or other soil problems disclosed during construction". Section 306 (a) 12. ;,(. Submit soils classification determination by a licensed engineer or architect based on observation, tests, borings, or excavations, and containing coD111ents on the degree of expansiveness, compressibility and bearing value. The report shall include foundation reco111Dendations. Section 2905. ,I.. Note on the plan the soils classification, whether or not the soil is expansive, and note the allowable bearing value. Section 2905. -/s. The foundation plan does not comply with the soils report recommendation for this project. Please review the report and modify design, notes and details as required. f· Provide notes on the foundation plan listing the soils report reconanendations for foundations slab and building pad preparation. f. Note on the foundation plan that 11Prior to the Contractor requesting a Building Department Foundation Inspection, the soils engineer shall advise the building official in writing that: 1. the building pad was prepared in accordance with the soils report; 2. the utility trenches have been properly backfilled and compacted, and; 3. the foundation excavations, farmings and reinforcements, comply with the soils report and approved plan11• J'· Provide spread footings for concentrated loads designed for 1,000 PSF soil bearing or per bearing value as determined by an engineer or architect. Chapter 29. 1t/. Show height of all foundation walls. Chapter 23. 8(S. Show height of retained earth on all foundation walls. Chapter 23. J1. Show distance or fill slopes and of cuts and fills. of foundation to edge of cut show steepness and heights Chapter 29. f· Note on plans that wood minimum above finish grade. 7. shall be 611 Section 2516 (c) (a;) Note on plans that surface water will Vain away from building and show drainage pattern and key elevations. Section 2905 (f). i. Dimension foundation per U.B.C. Table 29A: Floors SUJ:!I!Orted* Stemwall Width ~ 1 6" 1211 12" 2 8" 1511 l&" 3 1011 1811 2411 *Foundations may support a roof in addition to the floors, where only a roof is supported, use foundation for one floor. r_• Show foundation sills to be pressure treated, or equal. Section 2517 (c) 3. ~. Show foundation bolt size and spacing. Section 2907 (e). @ Specify size, I.C.B.O. number and manufacturer of power driven pins. Show edge and end distance and spacing. Section 306 (f). a/· Show size, imbedment and location of hold down anchors on foundation plan. Section 2312 (f). ~--~-• f· Note on plan that hold down anchors be tied in place prior to foundation inspection. Section 2312 (£). must i· Show adequate footings tmder all bearing walls and shear walls. Section 2311 (e). CJj... Show stepped footings for slopes steeper than 1:10, Section 2907 (c). 9/.. Show minimum 1811 clearance from grade to bottom of floor joists and minimum 1211 clearance to bottom of girders. Section 2516 ( c). 9/. Show pier size, spacing and depth into undisturbed soil. Table 29-A. ,f.. Show minimum widerfloor access of 1811 X 24". Section 2516 (c). c/s. Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of under floor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c). f6. Specify that posts embedded in concrete shall be pressure treated per UBC Std. No. 25- 12. Section 2516 (c). I. 1IWIIllG {9]) Show wall bracing. Every exterior wood 's(ud wall and main cross partition shall be braced at each end at least every 25 feet of length with equivalent. 1X4 diagonal let-in braces or Section 2517 (g) 3. ~. Note cross bridging or blocking. Floor joists and rafters 1211 or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held in line. Sec. 2506 (g). Q Show blocking at ends and at supp~rts of ){oor joists, and for rafters at exterior walls. Section 2517 (d) 3. 100. Show solid blocking at ridge line and at /xterior walls on trussed roofs. Section 2506 (g). /i. Show double joists. Floor joists shall be doubled under bearing partitions rurming parallel with the joists. Section 2517 (d) 5. ~-Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center where rafters and ceiling joists are not parrallel. Section 2517 (h). ~3. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h). ')!64• Show 1/2° minimum clearance between top plate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). @ Show double top plate with minimum 4811 lap splice. Section 2517 (g). €) Table Show nailing will 25-Q. be in compliance with @ Show or note fire stops at the following locations per Section 2516 (f): e in concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10- foot intervals along the length of the wall. at all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; in concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the nm of stairs if the walls under the stairs are unfinished; and f7'\. in openings around vents, pipes, ducts, \::::,;/ chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. y{s. Show stud size and spacing. Maximwn allowable stud heights; Bearing wall: 2X4 and 2X6 max. 10';-Non-bearing: 2X4 max. 14', 2X6 max. 20'. Table 25-R-3. J/J9. Note an A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the Building Inspector prior to erection. Section 306 (f). G Detail al 1 post to beam and post to footing connections. Section 2516 (c). P,1,,-e11.e:>Jc.e orr,.,~ "TD PUHi. l/1· Detail shear transfer connection including roof and floor diaphragms to shear walls. Section 2513. 1]J. Specify nail size and shear walls, floor and roof Indicate required blocking. diaphragm dimension ratios. K) and Section 4713 (d). spacing for all diaphragms. Maintain maximum (Tables 25 I, J, ip· Show 311X411 or 211X6" studs in first story of three story building. Table 25-R-3. )1.4. Provide truss details and truss calculations for this project. 1/.s. Provide roof framing plan and floor framing plan. Section 302 (a) 7. § Provide framing sections throu['h 8()01 ,2../ 51,W(.u s:ue!'P€T OP -l,'l,JQ fJDC,f· Section 302 (a) 7. ~-Specify all header sizes for opening over 4' wide. Section 2517 (g) 5. @ Provide calculations for q< :Ila CJ 6) {(g "().c.. Section 320 (a) 7. G Show on the plans all structural requirements developed in the structural calculations. ,'o. In areas subject to water splash and in exterior locations, wood colunms and posts shall be supported by piers projecting at least 211 above the finished grade and shall bear on a metal base plate or treated wood unless the columns or posts are foundation grade redwood or cedar. Section 2516 (c) 4. 1-f.. Show location of attic access with minimum size 2211 X 30". Section 3205. e) Show draft separation between Wlits in a duplex. for attic areas Section 2516 (f). /3. Show draft separation for space between dropped ceilings and floor above in excess of 1,000 sq. ft. Section 2516 (f). i/4. Specify plywood grade and panel indentification index. Table 25-N. 1is. When roof pitch is less than 3:12, design ridge as a beam. Section 2517 (h). 1'(t,. If foundation cripple wall studs are less than 14" framing shall be solid blocking. Section 2517 (g) 4. -----f-,-~~·· 1¥. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. JJ'. Show plywood sheathing over exposed eaves, or other weather exposed areas, is exterior grade. Section 2516 (g) 3. 1~. Show a weep screed at the /late line on all exterior stud stuccoed. Section 4706 (e). foundation walls to be 1l'b. Show corridor width to le~tion 3305 (b). be minimum 3611• 1~. Specify truss layout for 3011 X 3011 attic rc~ess. 137-Ridges, hips, and valleys shall be at 1fuist one size larger than supported rafters. Section 2517 (h) 3. fi33' Provide metal straps across ridge beam ~ rafters. J. lll!CIIAIIICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 1'1+. Show the size, location and type of all heating and cooling appliances or systems. ~ Show method of providing combustion air M-urnace, per Chapter 6, UMC. 1-f,. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC Sec. 1211. 1/. Show minimum 3011 deep unobstructed working space in front of furnace. 1i8. Note on plans, clearances to be per manufacturers listing. Section 704 UHC. 1~. Furnace shall not be installed under any stairway. Section 704 UMC 1/4tJ. Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space with access only through such room, unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. 1'i· Show I.C.B.O. approval for prefab fireplace. 1zl.. Show access to the attic or underfloor /urnace to be minimum 30 inches by 30 inches. Sec. 708 & 709 UMC. ~ Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide. Section 708 UMC. 1f. Show permanent electrical outlet and lighting fixture controlled by a switch for the attic furnace. Section 708 UMC. 1/s. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. e. Note on plan, gas vents and non- combustible piping passing through three floors or less shall be effectively draft stopped at each floor or ceiling. IJBC Section 1706 (a) 6. It. ELECJl!ICAL (IIA:rIOIIAL ELECIIUCAL CODE) All wiring shall comply with the National Electrical Code. ~ Note on the plan the amperage of ~ctrical service. ,/s. Show location of all electrical le~eptacles. ----------,~ ... ~.~ 1f. Electrical receptacle locations and/or spacing is not adequate in ________ _ § At least one receptacle shall be installed outdoors, in basements and attached garages, other than laundry outlets. Art. 210-25 (b). /isJl. Show minimum dwelling lighting (NEC Art. )i-6-26 (a) and GFI's in garage, baths and outdoors. NEC Art. 210-8 (a). @ Art. Note "UFER" ground to be provided (NEC) • 250-81. L. PLIJIIBIIIG IDIIDOIIII PLIJIIBIIIG CODI!) All plumbing shall comply with the Unifom Plmbing Code. fis3l Show water heater size, type and location ~lans. e, Show method of providing combustion air to fuel burning water heater. Section 1307. If vented door, vents must be at top and bottom. 1JI. Fuel combustion water heater shall not be installed in bath or bedroom•or in a closet opening into bath or bedroom. Section 1309. ~ Provide adequate barrier to protect water heater from vehicle damage. Section 1310. ¥.1. Show T and P Valve on water heater and show route of discharge line to exterior Section 1007 (e). ~ Provide dryer vent to outside. UMC Section 1903. @. Note on the plan that hose bibbs and lawn sprinkler systems shall have approved back.flow prevention devices. Section 1003. H:J,. Shower stall shall acco111DOdate a 3011 Jrcle and have a minimum floor area of 99G sq. in. UPC 909 (d). /0,;y M. IIOISI! IIISULATION (DUPLl!Xl!S) 6:611 Show details of duplex comon (party) ~sand floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibles and on Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibles. Title 25. MDT£' ..ST<'._ i?flT/IJt; DoJ l'L1'N. @. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating, ventilating or exhaust ducts shall be sealed, lines, or insulated to maintain required sound transmission rating. Title 25. 1¥3. Provide insulation in walls and ceiling to achieve SIC of 50 between garage and living area if garage use is not controlled by resident Title 25. 164. l!lll!RGY OOIISl!RVAYION: PL1!ASI! R1!AD New state mandated regulations ( calif. Admin. Code) became effective June 16, 1983 and require that the design satisfy one of the alternative energy packages A, B, C, D, E, 1, 2, 3, 4, 5, 6 or AB 163. The law also requires that many mandatory conservation items be satisfied. Show on the title sheet of the plans, the alternative energy package that was selected i.e., A, B, c, D, E, 1, 2, 3, 4, 5, 6 or AB 163 to show compliance, and provide calculations and other data, appropriate to that selected package. 1d. The responsible designer should sign a lt~tement, on the plan title sheet, 0 The design submitted substantially conforms to the Energy Regulations for Residential Buildings." • 1¥. Show the 11R" value for the walls, floors, ceiling and related areas. Q. Provide a schedule on the plans showing ~rmal mass requirement. Specify rooms, materials, required area and thickness of materials. / r f'rfPllC. Af;/.i; fi68) Show double glazing as per Energy ~lazing Schedule. / P f-'tf/)1,/C. n,(Ni;; Design, 8 e will Show total glazing areas on the plans. Show on the plan how shading requirements be satisfied. / F f'tfPl/e. P&.c., 1ji. Show on the plans details of required movable insulation. Show how the curtains or device will be sealed and gasketed to provide a dead air space. yi• lbe plans are not in compliance with the energy conservation compliance package selected or design calculations provided. Show on plans conformance as follows: 1f3. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled) "Mandatory Energy Conservation Requirements". @ Show the size, type and location of the space heating (or cooling) system and provide energy calculations if the output B11J/Hr- exceeds 45 non • .5~ ~ 1'11.J It ' 1fs. outdoor pools and spas with fossil fuel ?eaters require pool covers as well as other energy saving devices such as time clocks, etc. T20-l406. CARLSBAD s. F .D. & D11PL1X SUPPLIIIIEIIT @ Note on the plans, all work shall comply with the 1982 UBC, -UPC, 1984 NEC, -- UHC. Si£/§ 1 fl, 1/,. Lateral load design should be based on Seismic Zone 4. 678\ Energy conservation design should be for ~e 7. See attached energy packages. e All require a that roof 3203 (e). buildings, except M Occupancies fire retardant roof. Note on plan is to be fire retardant per Sec. 5e€ f/1.$ l!.lJef't::c..T!oll 5.;... 9. Show location of electrical panel; cannot be in a concealed location. yrf. P. & T. drainlines must drain to a floor sink, floor drain or to the exterior, they cannot discharge into an upright sink. lfl • Townhouses (postage stamp lots) must have walls and utilities in accordance with attached City Policy 80-13. J3. Floor drains must have auto-prime (city policy). {i;;) Note exhaust fans cannot be ductless type 'tc{ty policy). 1f. New residential units must be pre-plumbed for future solar water heating. Show two roof jacks where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). e Two 3/4" copper pipes must be installed from the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). ... G9. All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy). 1/,s. Incorporate the waterproofing details, on the attached Policy 80-8, where interior living space occurs below grade at the masonry wall(s). Q Show on the Title Sheet of the plans, the ~rmation required by the attached Developmental Services Sheet The City of carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perfom the plan check for your project. If you have any questions, please contact _______ _ £!Le£/\} W&LKf& at Esgil Corporation. If you have any questions regarding permit procedures, please contact carter Darnell at the City of CArlsbad, 1200 Elm Avenue, telephone 619/438-5525, Thank you. Enclosures: 2. S TC.. • .S ()I, CS.- 3. • ----------1·- ' .. Date 1 //-,fl,;/.-~ Prepared bys £. '»AL H !?fl-' Jurisdiction C,,14,? LS~ 14.tJ VALUATION AND PLAN CHECK FEE PLAN CHECK NO. 5<5"-4,79 BUILDING ADDRESS ST □ Bldg. Dept. □ Esgil APPLICANT/CONTACT _c:&~,'-"-,8"14~&~L.J..J.Jft~AL1LY~I-- BUILDING OCCUPANCY _ __.R.,_-..;;3,__/,_,m~-1 __ PHONE NO. 2:::r5-00a5" ; DESIGNER PHONE _____ _ TYPE OF CONSTRUCTION __ ...:cv_-.;.:w'-----CONTRACTOR PHONE ------ BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER "=• '...,_ ., ..... '-/;)...OD 58 o( II,:,,/_,-, -. f"_ -~ ,, . .-..r:; '""D Ii/ , I,.. ---. , ----- I l',F, ·"' / ·.• ,~112< J./, J ,-, ·9 -3 9 t,r. ' Air Conditionin~ Commerc1.al @ Residential ta Res. or Comm. Fire Sllrinklers Total Value Fee Adjusted To Reflect @ ., 0 Energy Regulations {Fee x 1.1) 0 Handicapped Regulations -------f---,~-. o1.~~I~ 8/4/82 I .. .... ~ ... ' Z237 · PLAN CHECK NUMBER gs--6 7f ADDREss __ ,L_£ __ v_,_VJ-~-----e_ ____ DATE //-/ f -fS- ZONE: e-'2-PLANNING: TYPE OF STRUCTURE . ~ SCHOOL FEES: SAN DIEGUITO v" ENCINITAS ------ CARLSBAD --------SAN MARCOS ______ % COVERAGE -----------REQU-IRED SETBACKS ----BUILDING HEIGHT --------~ FENCES/WALLS ____ ~----,,,.:;.__--,. TWO CAR GARAGE 0/::_ ------+--~;..,_ FRONT 1A) 1 -------i' rnv rnm:~-iENTAL RE:QUIREQ: ---------------------- ADDITIONAL COMMENTS: ----------------------- OK TO ISSUE: DATE: \ '\ I(, OK TO FINAL: DATE: ------------- * * * * .>::·::..·~: *~**~ t:t~-.":~~-;~~:~~*-!:r-!:*-t:? ... ·~-: .. ~ ... ":~'.:~~*****~~-::-: .. ··:..·•:..•:·.:* **** ** **-W~),.. * ****** * * ************ * l ENGINEEfUNG ~ ~ ~ ~ ~ ~ ::-----,-,.~-~,.........,'T"'--i,.,....,~-~=-E. D. U: ,L_ .C. J1,( .0. "~EWER: ~o~~-t?=--6(--u-.U-Zl-.,-~--~. -- . \. ~ LATERAL: ~ ;i'z6, -.z___ 'ow:EWAV: ........,.J_ ~•tj& ~ u.1 GRADING PERMIT: p✓~-~ 4t:-o~ ~ ~ DRAINAGE: cS/,bW oN ~ 0::1 0 EASEMENTS: ~ ~ ADDITIONAL COMMEN 1.u- ~ □ 6~□ ~§ D ' ~ ,,~. L.. u o:: OK TO ISSUE: ~ / DATE: _ __:./✓,,&.1//(-'-,;.l?::.,.af4'""-""...,~ ........ --~---- / / ' * ENGINEERING INSPECTION REQUIRED: ________________ _ PUBLIC lo!ORKS INSPECTOR: __________________ _ FINAL OK: ----------DATE: __________ _ * IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS (DRIVEWAYS, CURB CUT, DRAINAGE, ETC.) DEVELOPMENTAL SERVICES BUILDING DEPARTMENT (itp of (arlsbab 1200 ELM AVENUE CARLSBAD, CALIFORNIA 92008-lffl (819)438-5525 DEDICATIONS OF LAND AND FEES FOR SCHOOL DISTRICTS , CH,APTER 21.55 CARLSBAD MUNICIPAL CODE RETURN TO: BUILDING DEPARTMENT City of Carlsbad 1200 Elm Avenue Carlsbad, CA 92008 FROM: School District SAM DIEGUITO UNION fflGff SCHOOL D!STRICJ' © Plan Check No. Property owner's Name Project Address Name of District 753-6491 Effective Date D-a-,-t_e_P=cl,--an--,Ch=-e-c.,.k-Fe_e_P.,.d4•. Project Site Legal Description--..,,.-,,--...,,..-,---=-=------- Project Site Assessor's Parcel No. ,J/(; .21/0-Os"' Project Des=iption -Incl. no. of dwelling units DPLE ,{ -36D Department Official -=s""ign-a""t,..ur_e ____ _ Title Qo7)v Date SCHOOL DISTRICT CERTIFICATION I certify that the requinm!nts of Ciapter 21. SS. of the carlsbad M.ru.d.pal Code li:lr school facilities dedicat.ion of la,d '"1d fees have been satisfied li:lr the -cri.bed project. 1-8-86 Date Note to ~i<3'lt: A review of cne set plans may oe required by the sdlc:ol district. LEUCADIA COUNTY WATER DISTRICT APPLICATION FOR SEWER SERVICE The application must be signed by the owner (or his representative) of the property to be served. The total charges must be paid to the District at the time the application is submitted. APPLICANT MUST SUBMIT EVIDENCE OF BUILDING PERMIT WITHIN 60 DAYS. FAILURE TO MAKE SUCH SUBMITTAL WILL RESULT IN AUTOMATIC CANCELLATION OF THE SEWER PERMIT. THE SEWER CONNECTION FEE LESS A $50 ADMINISTRA- TIVE FEE WILL BE REFUNDED. A six-month construction period shall be provided and sewer service charges for the bal- ance of the fiscal year shall be collected at the time of application for sewer permits. Sewer service charges for subsequent fiscal years shall be collected on the tax roll in the same manner as property taxes. If the six-month construction period extends into the sub- sequent fiscal year, a prorated sewer service charge for that fiscal year shall be collected on the tax roll in the same manner as property taxes. The full sewer service charges for all subsequent years shall be collected on the tax roll in the same manner as property taxes. There will be no additional fee or refund if service actually commences on a different date. The prorated sewer service charge shall not be required in those applications for sewer permits for subdivisions. Such applicants shall be required to notify the District, on forms provided by the District, of escrow closings on individual properties within the subdivision. Sewer service charges shall commence upon close of escrow and will be the ~esponsibility of the buyer. ff~ service late7al is req~ired, it will be installed by the Leucadia County Water District. The service lateral is that part of the sewer system that extends from the main collection line in the street (or easement) to the point in the street (at or near the applicant's property line) where the service lateral is connected to the applicant's building sewer. The applicant is responsible for the construction, at the applicant's expense, of the sewer pipeline (building sewer) from the applicant's plumbing to the point in the street (or easement) where a connection is made to the service lateral. The connection of the applicant's building sewer to the service lateral shall be made by the applicant at his expense. The connection must be made in conformity with the District's specifications, rules and regulations; and IT MUST BE. INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT. THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE MUST NOTIFY THE DISTRIC'!-' AT THE TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLECTION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND WILL NOT BE ACKNOWLEDGED. The Inspection Deposit will be refunded upon the completion of satisfactory inspection of the connection to the District's sewer system. The inspection deposit shall not apply in those cases in which the applicant has paid plan check and inspection fees for a subdivision. OWNER'S NAME: Joseph & Rozalia Kaplar CONNECTION FEE: $ 3,000.00 MAILING ADDRESS: 2579 Luc1ernaga LATERAL SIZE: ; EASEMENT: Carlsbad 92008 EXTRA FOOTAGE-: -@$ /Foot PHONE NUMBER: 931-1783 EXTRA DEPTH: @$ /Foot SERVICE ADDRESS: 2237 & 39 Lev ante LATERAL FEE ---- LOT NUMBER: 215 INSPECTION DEPOSIT 50.00 TRACT DESCRIPTION: La Costa llril¥ So. #3 PRORATED SEWER SERVICE FEE ASSESSOR'S PARCEL NO: 216-240-50 TOTAL $3,050 • 00 TYPE OF BUILDING duplex NO. OF UNITS_2_ PAID BY: CASH CHECK N0.191 RECEIVED BY:B.Savill The undersigned hereby agrees the conditions as stated. that the above information given is correct and agrees to ~£,{~;i~e/4,z 1/9/86 17729 Date Account Ne • •• • l JlrjlmJ.lla Olivenhain Municipal Water District -A Public Agency 1966 OLIVEN HAIN ROAD• ENCINITAS, CA 92024 • (619) 753-6466 NAME AND ADDRESS FOR BILLING: DATE )-IC ~0 I WORK ORDER# t:5' ACCOUNT NO TYPE OF SERVICE NO Of UNITS 4-1 SIZE METER S-/2?'' MONTHLY MINIMUM ~~ Name: __ .....;V::.:.V/.:;__7_..:..:.....;;..Jl=_.....;x~A..:..:....P...;;./...;;.Ll;;.;.;.,:R:;__ ________ _ METER LOCATION 22.3:1/2 2 ) Address: __ ,,:)_o,_7_9 _____ )__,_(.._IC ......... t .... 1 .... P_.l{ ......... 14 ..... /4_-....,.✓,'""'').---------L I'S 1 ./ A ti./ 7z. -2 I Phone: ___ ..,.-J ____ °=J'---/-~/_7~£=3~---------APPLICATION TAKEN BY: -LI I?--/,, /,;ry / ACCOUNT PRICES QUOTED ARE SUBJECT TO CHANGE WITHOUT NOTICE NO. COST OF METER AND INSTALLATION ............ ,P .. X. .... ~. //.~ ......... . 22720 $ .,.;; 3t'J /' ----------- CONNECTION FEE (less credit$ ______ ) .-PX ... ~!..tf.4-.~-: .... . 49910 $ :2 ~ 5c. ( c.. PIPELINE EXTENSION CONNECTION FEE (Ext.# ____ ) .............. . 22750 $ ----------- DEPOSIT ( ________________ ) ............. .. 22850 $ ----------- JUMPERS( ________ ~ _______ ) ............. .. 13710 $ ----------- ·····················································p ····A···1···0·········· $ ----------- JP.N l O 1986 TOTAL PAID: $ _ ___:.._3:=:....:.......:.,;/)::....R,=;,-::.....:......:t',:...:...._ __ Sec. 7057, Title 17, (Public Health) Cal. Adm. Code System Pressure: (a) Normal operating pressure at the service connection shall not be less than 25 pounds per square inch gauge (p.s.i.g.) nor more than 125 p.s.i.g., except that during periods of hourly maximum demand at the time of peak seasonal loads the pressure may be not less than 20 p.s.i.g. and that during periods of hourly minimum demand the pressure may be not more than 150 p.s.i.g .. Variations in pressures under normal operation shall not exceed 50 percent of the average operating pressure. The average operating pressure shall be determined by computing the arithmetical average of at least 24 consecutive hourly pressure readings. (b) In a water system supplying customers at widely varying elevations, the utility may furnish a service which does not comply with the foregoing pressure specifications, if the customer is fully advised of the conditions under which average service may be expected, and the customer's agreement is secured in writing. (c) New water systems, or new pressure zones in existing water systems supplying customers at substantially constant elevation shall be designed to maintain an operating pressure at the service connection of not less than 35 p.s.1.g. nor greater than 1 00 p.s.i.g .. The undersigned applicant acknowledges that he has read, had explained, and understands Sec. 7057 of Title 1 7, (Public Health), Cal. Adm. Code and agrees to accept water service at not less than-~--p.s.1.g. and not more than_~~-p.s.i.g .. "I HEREBY AGREE TO ABIDE BY THE RULES AND REGULATIONS OF THE OLIVEN HAIN MUNICIPAL WATER DISTRICT AND I AM IN RECEIPT OF A COPY OF THESE RULES AND REGULATIONS." INSTALLATION OF METERS ARE SCHEDULED ACCORDING TO THE DISTRICT'S CURRENT WORKLOAD. TEMPORARY CON-STRUCTION METERS FOR CONSTRUCTION USE ONLY. SIGNATURE _ ___:c.c..=c::.....:..:..!.....!.....::.::?:::::..C....:-l!X~A~~!::....---1!.r'---~ -----------FOR DISTRICT USE ONLY----------- METER # __________ STARTING DATE ________ METER SIZE ___________ _ METER TYPE ___________ DIALS ____ UNITS ____ RATE CLASS _____ READG. __ _ R/C __________ M/C _________ T.M. BOOK ________ COMP. _______ _ ATTENTION PROPERTY OWNER: An "owner-builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information in the envelope provided at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) Y e.s V 2. I (have/have not) -------signed the application for a building permit. 3. I h~;o";lacted with the following person (firm) to provide the proposed construction. / Name CZ. Address ,,R. -7 ll er' e City Cqr' u pqq' Phone _....,f..::.3;..:l_-.;..l:::;.3,.;;.,C,.;;...',,c.,;;;._ __ _ Contractors License No. ----- 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work. Name ------w----,.L~'-}+--:,'p..,.,_,,.,../o:a_ __ ~:::e_ss_·-=----_-7,:-_A-:_~----+__,/-,,.:Z'-._-{&--_:-_-_-=._-=._-= Phone ------------. Contractors License No~ ____ _ S. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Phone Type of Work Signed: Property Owner I <j> <~J&M-! r~d0z- Socia1 Security Number,( 30 0 -3 G -If' J. 3 !:? Date: Y ::, / OH IO -g,c. , e EACH SUBCONTRACTOR WILL BE INSTRUCTED TO OBTAIN A CITY OF CARLSBAD BUSINESS LICENSE AND FURN ,HA CERTIFICATE OF WORKMAN'S COMPENSATION TO THE CITY OF CARLSBAD. x-7~£-Initials DEVELOPMENTAL SERVICES BUILDING DEPARTMENT Dear Property Owner: <trttp of <trarlsbab 1200 ELM AVENUE CARLSBAD, CALIFORNIA 92008-1989 (619) 438-5525 An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "owner-builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by the property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. · Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City of Carlsbad. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and pro- tection. If you employ or otherwise engage any persons other than your i1T111ediate family, and the work (including material and other costs) is $200 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the state and federal government as an employer and you are subject to several obligations including state and federal income withholding, federal social security taxes, workers' compensation insurance, disability insurance costs, and unemployment contributions. There may be financial risks for you if you do not carry out these obligations and these rfsks are especially serious with respect to workers' compensation insurance. For specific information about your obligations under federal law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own emoloyees, without a 1 i c.ensed contractor or subcontractor, only under limited conditions. , A frequent practice of unlicensed persons professing to be contractors is ,o secure an "owner-builder" building permit, erroneously implying that the property 01<,jfi:er is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Informa- tion about licensed contractors may be obtained by contacting the Contractors State License Board in your co1T111unity or at 1020 N Street, Sacramento, CA 95814. PLEASE COMPLETE ANO RETURN THE ENCLOSED OWNER-BUILDER VERIFICATION FORM SO THAT WE CAN CONFIRM THAT YOU ARE AHARE OF THESE MATTERS. THE BUILDING PERMIT WILL NOT BE ISSUED UNTIL THE VERIFICATION IS RETURNED. Very truly yours, Building Department City of Carlsbad