Loading...
HomeMy WebLinkAbout2362 HOSP WAY; ; CB011036; Permitli -02-13-2002 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Miscellaneous Permit Permit No:CB01 1036 Building Inspection Request Line (760) 602-2725 Job Address: 2362 HOSP WY CBAD Permit Type: MISC Subtype: REPAIR Status: ISSUED Parcel No: 1672504241 Lot #: 0 Applied: 03/15/2001 ;-Valuation: $10,000.00 Entered By: CB :,:Reference #: Plan Approved: 05/29/2001 Issued: 07/03/2001 Project Title: THE GROVE-BRIGDE REPAIR&4 NEW Inspect Area: RCB LIGHT POLES FOR PARKING STRUCTURE AppIicant: Owner: STEVE DAHLBERG THE RENAISSANCE CONTINUUM TAYLOR FRANKLIN M y5UITEC S , 0867 02/13/02 0002 01 02 '14661 MYFORD RD / 2362 HOSP WAY #133 COP 14000 -TUSTIN CA 92780 / (/ \ ç CARLSBAD CA 92008 714-734-0466X11 / / Total Fees: $319.00 - \Total Payments To Date: $179.00 Balanbe Due: $140.00 Miscelaneous Fee #1 Miscelaneous Fee #2 Additional Fees TOTAL PERMIT FEES / PERMIT FEE LIGHT POLE FEE 5" J V. \c \\ (/ '1 ci $179.00 - $140.00 $0.00 $319.00 FINAL APPROVAL 041 511glIo 2- _________ Inspector: /'"'"" Date: ______________ Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. FOR OFFICE USE ONLY PERMIT APPLICATION I PLAN CHECK NO CITY OF CARLSBAD BUILDING DEPARTMENT; EST. VAL /4Q 1635 Faraday Ave., Carlsbad, CA 92008 0 Plan •Ck. Deposit (0 f Validated By _ 0 , 0 Date RD ôp VcLy ' ... . Address (include Bldg/Suite #) Business Name (at this address), Le ) Description Lot No. Subdivision Name/Number 0 Unit No. 0 Phase No.0 0 Tétal #'of units 9'( 7- 5C — / 4.( ,, " ' . , 0 :.. " •• Assessor's Parcel # 0 0 0 .....Existing Use 0 0 0 Proposed Use O cc€ .EPM S AD •. 0 47' , ,,,• , Description of Work 0 0 SQ. FT. 0 #of Stories 0 # 'of BedrooWi's' VL ')Uofathroois 0 0 'o 7- R MWi1ppin f,o// (JJ 74 L& j44 M'Foa-o <0. Te '14T7J (k 19;leo. "- O .Name 1,11,4 "rf) fj7A ddre(C%w /1 '/ / City (. . "State Zip Telephone # 0 0 .,..,v.,_,. i . .,.,. ,,,,,,,, . ... 3 APPLI ANT cntract Agent f rnractor,, Owner A 4nt for Ow ur L. / Ti 4' ao w /%:/9 I// Name - , dress 07. City 2A5 Stat /Zip (_T%eP)o! ERTY oWN -' 7 3t - 2i '.'1yft O 4JM cwcrjog zwm &5 ,4*. 0 o. 0 Name. - Address 0 City 0 o . State/Zip ' Telephone # tLS&QNILQP YJJA O (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure,. prior to its O 0 ',issuance, also requires the applicant for such .permit to file a signed statement that he is licensed pursuant 'to the provisions of the Contractor's' License Law, [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that- he is exempt therefrom, and the basis for the alleged O , exe tion. Any vi tion of Section 7031 .5'by any ap lic t for a permit subjects t a plicant to 'a civil penalty of not mar than five hu r d II rs l$500 . ' -4i sfr/r /w,, &*v1, ?) Name 0 / Address , 0 0 City State/Zip , Telephone # 7 0 0, •0 ','".' 0 ' 00 State License fi ' / ( (V— 0 .,,License,Class 0 , City Business License # - 0 Mz 'fr,v 'Designer Name 0 ''' ' Address ' 0 ' '"' City State/Zip Telephone 0 '0 State License# 6 \JERS,._QQ4N1OJ - O :Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of.the following declarations: 0 I have and will maintain a certificate of consent to. self-insure f or workers'. compensation as provided by Section 3700 of the Labor Code, for the performance ,of the work for which this permit is issued. . .. ... 0 ..................0 I have and will m)int,in workers' cçi5npensation, as required.by Section 3700 of the Labor Code, for the performance of the work for which this permit is O , "issued. My worker's 4tiofrQ1 oe carrier and policy number are: 0 0 , 0 Insurance Company ~ I &i - Policy No.04 g'ç' c . ' Expiration Date _ \it I14.. o '(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) O 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as -to become.subject to the Workers Compensation Laws of California. - • 0 0 • 0 -- WARNING,: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties'-'arid civil fines up to one hundred thousand dollars ($1100,00611, in addition to the'cost of compensation, damages as provided for in Section 3706 of'the Labor code, interest and attorney's fees. , ,SIGNATURE __. 0 , 0 DATE ' '0 ' 0 • 0 17. Wb1ELT I hereby affirm that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the-structure snot inteided or offered for sale O ' '(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who bUilds or improves thereon, and who does such work himself or through his own employees, -provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose' of sale). - ,D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code:. The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and dontracts for such projects with contractor(s) 'licensed pursuant to the Contractor's License Law). 0 . ' 0 0 1 am exempt under Section' 0 Business and Professions Code for this reason:' "1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES 2.. ((have /-have not) signed an application for a building permit,for the proposed work. • ' . 0 0 , • 0 0 - ' , 0 ,3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors.,licene humber): 4.., I plan to provide portions of the work; but I have hired the following person to coordinate, superviseand provide the major work (include name address / phone number / contractors license number): 0 0 0 04 0O,00• I will provide some of the work, but'l'have contracted (hired) the following persons to provide the work indicated (include name I address I phone number) type of work): 0 •• ', 0 - ' •'• 0 :pop-y OWNER SIGNATURE 'DATE - Is the applicant, or, future building a required tO submit •a business plan, acutely hazardus materials registration o m or risk 'management and prevention program under Sections 25505, 25533 •or 25534 of the Presley-Tanner Hazardous Substance Account Act? • 0 YES' NO O ''• '(s'the applicant or future building occupant required to obtain ,a permit from the air pollution control district or air quality management district? 0 YES NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? 0 YES No IF ANY OF THE ANSWERS'ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY N0TBE ISSUED UNLESS THE APPLICANT HAS MET OR,IS MEETING THE - REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 0 0 • • • - O 0 'l hereby affirm'that ther is a construction lending'agency for the performance of the work for which thispermit iC issued (Sec. 3097(i) Civil Code). ' LENDER$ NAME : -LENDER'S ADDRESS _, ' • 0 [P , certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all '0 , City ordinances and State laws relating to building construction. 'I hereby authorize representatives of the Cit' of Carlsbad to enter upon the above mentioned • property 'for - inspection purposes. 'I "ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST WALL LIABILITIES. O 0 JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OFJHIS'PERMIT..,. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height: EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire-by limitation and become null and void if-the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work iuthorized by such permit is suspended or abandoned at any time after the work is corn • edArToeriod of 180 days (Section 106.4.4 Uniform Building Code).': 0 •' - 0 ' PPLASlGNATUR1 TEV' 1j(e) - 0 ,, • - WHITE: File YELLOW: Applicant . PINK: Finance - -. - 0 ' • , - •• - iO 0 r '-' -. -'- -__ -'-'- ,.'." , '•'' _-'.--. "__ -,,..--- '.' " '•'' ''•_••• '-"- FOR OFFICE USE ONLY. PERMIT APPLICATION PLAN CHECK NO CITY OF CA1RLSBA0 BUILDING DEPARTMENT' . :' EST. VAL. 1635 Faraday Ave:, Carlsbad, CA 92008 . .. Plan .Ck. Deposit '..' Validated By Date_______________________________ 11 Address (include Bldg/Suite #) Business Name (at this address) 77-ie rov 'Legal Description , ....,, ' Lot No. Subdivision Name/Number Unit No. Phase No.. ' Total # of units Assessor's Parcel # ' Existing Use Proposed Use , Description p_____bP Name Address City State/Zip Telephone# Fax # , jPyLlCrtNT Contractor 4 _e e cxk+ s+c4o i ~ 17 9f o Hl' /? (( O f .s C,4 92 #3 D r5 -3co 86 ':Name - Address City . ' State/Zip''Telephone"# - . PROPER1IY 0WNER . .. ' Name ' Address 77 7 ' : City ' State/Zip 'Telephone # - 20OMP )Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repairany structure, prior to its issuance, also requires the applicant for such permit-to file a signed statement that'he is licensed pursUant to the provisions of the Contractor's License Law ,[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subje ts h te applicant to a civil penalty of nof more then five,hundred dollars [$500)). C1d /2o , .S ',q q o . -so.-scZ - Name . ' Address . City, ' State/Zip . Telephone # State License # 7.~ 7O License Class . 'i ' ' City Business License # Designer Name Address City State/Zip Telephone tte License #' 6 WORKERSCOMPENSATIot WoikeW Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: - '.0 I have and will maintain a certificate of consentto'self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of tore.work for which this permit is issued: have and will maintain workers' compensation, as required by Section' 3700 of the Labor Code, for the performance of the work for which this permit is, 'issued. My worker's compensation insurance carrier and policy number are: . -,.,-lnsurance Policy No. I)lA)4_.S44-So5tO Expiration Date________________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) '0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued; I shall not employ any peron in any manner so as to become subject to the Workers' Compensation Laws of California. - - - WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000). in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. 'SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: o I; as owner of,-the property or my employees' with wages as their sole compensation, will do the work and the structure is not intended or offered for sale 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building' or improvement'is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, 'Business and Professions Code: The' IContractor's License Law does not apply-to an owner-of property who builds or improves thereon, and contracts for such projects with 'contractor(s) licensed tpursuañt to the Contractor's License Law). 0. I am exemptunder Section ' . Business and Professions Code for this personally plan to provide the major labor and'materials for construction of the proposed property im'provement. 0 YES DNO I )have / have not), signed an application for a building permit for the proposed work.- 1 have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number'/ contractors license number): '4. -,..I ,plan to provide portion's of the work, but .1 have hired the following person to coordinate, supervise and provide the májor'work (include name I address / phone 1'number / contractors license number): 5. I will provide sorRè of the work, but I have cOntracted (hired) the following persons td' provide the work indicated (include name I address / phone number I type of work): PROPERTY OWNER SIGNATURE " ' DATE * Is the, applicant or future building 'occupant required to submit a business plan; acutely hazardous materials registration form or risk management and prevention' program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? .0 ,YES 0 NO ')s the applicant or future building occupant required to obtain'a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT. BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE' -IREQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION_ L1 hereby affirm that there is a construction lendir'g agency for the performance of the work for which this pprrnit I I ued (Sec 30970) Civil Code) 'LENDER',S NAME LENDER'S ADDRESS TwcAT - ,I certify that I have read the application and state that the above information is correct ,and that the,information on the plans is accurate. I agree to comply with all - City ordinanbes'and State laws relating to building construction. I hereby authorize representatives of the Cit' of Carlsbad to enter upon the above mentioned ,'propérty for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. - 'JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by'the'building Official under the provisions of this Code shall expire by lithitation and become null and void if the building or work-' authorized by such permifisnot commenced within 180 days from the date o such per or if the building or work authorized by such permit is suspended or abandoned' - at anytime after the work is commenced for a. period of 80 days (Secti 1' 6.4.4Uriiform Building Code). ' ' APPLICANT'S SIGNATURE' ('i2..fiJ2ey.L,. ' ' ' ' DATE 'z/,3 I WHITE: File' YELLOW: Applicant PINK: Finance •,'., 'City of Carlsbad Bldg Inspection Request For: 05/13/2002 Permit# CB011036 S Inspector Assignment: RCB Title: THE GROVE-BRIGDE REPAIR&4 NEW Description LIGHT POLES FOR PARKING STRUCTURE Type: MISC Sub Type: REPAIR Phone: Job Address: 2362 HOSP WY • '' Suite: Lot 0 Location Inspector APPLICANT STEVE DAHLBERG THE RENAISSANCE CONTINUUM . - Owner:. 'Remarks: - -Total Time: . . • Requested By: DAVID ., . . Entered By: ROBIN . CD Description ' • Act Comments ' . 34 Rough Electric -. - Final Electrical )—D P6Rm r ,39 • . 4 I- * ' •-. Associated PCRs .....• .-.-• • I - Inspection History Date Description Act lnsp Comments 04/19/2002 11 Ftg/Foundation/Piers AP RC OK TO POUR 4 LIGHT POLES 02/22/2002 19 Final Structural CA RC 02/08/2002 -11 Ftg/Foundation/Piers . CA RC 01/25/2002 18 Exterior Lath/Drywall PA RC OK TO STUCCO #2382 *01/23/2002 18 Exterior Lath/Drywall PA RC OK TO STUCCO #2330 01/22/2002 18 Exterior Lath/Drywall . PA RC #2340, 2336, 2334, 2332 OK TO STUCCO :- 01/18/2002 18 Exterior Lath/Drywall CA JC .,01/16/2002 , 18 Exterior Lath/Drywall .CA RB 01/15/2002. 11 Ftg/Foundation/Piers NR JC 01/15/2002 14 Frme/SteeI/BoIting/WeIding NR JC S .* 01/07/2902 14 Frame/Steel/Bolting/Welding PA RC FRAMING AT #2336 OK TO WRAP . 01/07/2002 18 Exterior Lath/Drywall ' NR RC 01/03/2002 11 Ftg/Fotindation/Piers PA RC OK TO POUR PIERS - BRIDGE #2340 01/03/2002 17 Interior Lath/Drywall WC RC 01/02/2002 • 11 Ftg/Foundation/Piers PA RC FTGS, REBAR OK TO POUR 2336 . 01/02/2002 • 14 Frame/Steel/Bolting/Welding WC RC 01/02/2002 17 Interior Lath/Drywall WC RC 01/02/2002 18 Exterior Lath/Drywall • PA RC OK TO STUCCO 2360, 2344, 2342 (LEAVE OPEN AT BOTTOM AT DOORJAMB) 12/28/2001 18 Exterior Lath/Drywall - NR RC 12/18/2001 18 Exterior Lath/Drywall - PA RC LATH AT #2380 & 2362 OK TO STUCCO ,. ••• - . 5- 4_S • • . .....- • 5, - • ', r 4.. S ::. Inspection List Permit#: CB011036 Type: MISC REPAIR THE GROVE-BRIGDE REPAIR&4 NEW LIGHT POLES FOR PARKING STRUCTUR Date Inspection Item Inspector Act Comments 05/13/2002 34 Rough Electric - RI' 05/13/2002 34 Rough Electric RCB AP LIGHT POLES - OK 05/13/200239 Final Electrical RCB AP FINAL FOR PERMIT 05/13/2002 39 Final Electrical - RI 04/19/200211 .Ftg/Foundation/Piers - RCB AP OK TO POUR 4 LIGHT POLES -' 02/22/200219 Final Structural RCB CA 02/08/2002 11.' Ftg/Foundation/Piers RCB CA 01/25/2002 18 Exterior Lath/Drywall RCB PA OK TO STUCCO #2382 01/23/2002 18 Exterior Lath/Drywall RCB PA OK TO STUCCO #2330 01/22/2002 18 Exterior Lath/Drywall RCB PA #2340, 2336, 2334, 2332 OK TO STUCCO 01/18/200218 Exterior Lath/Drywall JC- CA 01/16/2002 18 '. Exterior Lath/Drywall RB CA 01/15/2002 11. ,Ftg/Foundation/Piers- - JC NR 01/15/2002 14, Frame/Steel/Bolting/Weldin JC NR - -- 01/07/2002 14 Frame/Steel/Bolting/Weldin RCB PA FRAMING AT #2336 OK TO WRAP 01/07/200218 Exterior Lath/Drywall RCB NR 01/03/2002 11 Ftg/Foundation/Piers RCB PA OK TO POUR PIERS - BRIDGE #2340 .,. 01/03/2002 17 Interior Lath/Drywall RCB WC 01/02/2002 11 Ftg/Foundation/Piers RCB PA FTGS, REBAR OK TO POUR 2336 01/02/200214 Frame/Steel/Bolting/Weldin RCB WC 01/02/2002 17 Interior Lath/Drywall RCB WC '! 01/02/2002 18 Extericr Lath/Drywall - RCB PA OK TO STUCCO 2360, 2344, 2342 - S . •- (LEAVE OPEN AT BOTTOM AT DOOR JAMB) '. . 12/28/2001 18' 'Exterior Lath/Drywall • ' RCB NR 12/18/2001 18 Exterior Lath/Drywall RCB PA LATH AT #2380 & 2362 - OK TO STUCCO 12/14/2001 14 Frame/Steel/Bolting/Weldin RCB AP 2330 2332 2334 2340 2342 2344 BRIDGE FRAMING OK TO COVER . 12/14/2001 14 - Frame/Steel/Bolting/Weldin RCB AP 2330 12/14/2001 14 Frame/Steel/Bolting/Weldin RCB AP 2330 12/13/2001 11 Ftg/Foundation/Piers RCB PA BRIDGE FTGS AT 2332, 2344 AND 2360 - ,. .12/13/2001 14 Frame/Steel/Bolting/Weldin RCB WC 12/11/200118 Exterior Lath/Drywall ' RCB PA LATH AT BRIDGE 2350 & 2352 , 12/05/2001 14 Frame/Steel/Bolting/Weldin -. RCB AP BRIDGE FRAMING #2350, 2352, 2380, : ' 2382, 2360, 2362 '11/20/2001 .11 Ftg/Foundation/Piers RCB AP #2330, #2334, #2342, OK TO POUR .• •-• ' ' - PIERS 1.1/07/2001 14 ,Frame/Steel/Bolting/Weldin RCB PA NEW SHEAR PANEL - REPLACED ROTTEN FRAMING 10/29/2001 11 Ftg/Foundation/Piers. ' RCB AP BRIDGE PIERS AT 2380 & 2352 - OK TO - . POUR •10/29/?001 18 Exterior Lath/Drywall -. RCB AP UNITS 138, 140, 142, 144 ALL THREE .5' - • FLOORS OK TO STUCCO 10/26/2001.11 Ftg/Foundation/Piers,, - RCB PA #2346 BRIDGE PIERS - OK TO POUR 10/26/2001 17 Interior Lath/Drywall RCB ' WC 10/26/2001 18- Exterior Lath/Drywall: RCB . AP UNITS 137,139,141,143,-ALL THREE FLOORS OK TOP STUCCO Tuesday May 14 2002 Page 1 of 2 - S • I 10/18/2001 18 ExteriOr Lath/Drywall RCB ". 09/11/2001 18- Exterior Lath/Drywall RCB 09/05/2001 17 Interior Lath/Drywall RCB 09/05/2001 18 Exterior Lath/Drywall RCB -08/28/2001 17 Interior Lath/Drywall RCB 08/23/2001 13 Shear Panels/HD's JC •08/23/200118 Exterior Lath/Drywall JC 08/21/200113 Shear Panels/HD's RCB 08/21/2001 18 Exterior Lath/Drywall RCB 08/20/2001i3 Shear Panels/HD's RCB 08/20/2001 18 Exterior Lath/Drywall RCB 08/09/2001 11 Ftg/Foundation/Piers RCB 4• ..•,', •,-. .-• ., 08/09/2001 12 Steel/Bond Beam RCB - •4. - - - -S. . . '5• , -• 'S ..; ............. .5 - - - .-• ' - - • r. -' ...-, - C . - •5._ , - .( - 'Tuesday, May 14,20O2 - - S. .; . 5 - S • AP UNITS NO 145-152 OK TO STUCCO AP 103,105,107,102,104,106,108,110,112,. 114,116-OK TO STUCCO WC PA UN ITS 1O9,111,113AND115ALL THREE FLOORS OK TO STUCCO PA 9 UNITS - # S ON BACK OF INSPECTION CARD - OK TO STUCCO WC PA OK TO STUCCO 8 UNITS - NUMBERS ARE ON THE BACK OF INSP CARD WC PA OK TO STUCCO 8 UNITS ( NUMBERS ARE LISTED ON BACK OF INSPECTION CARD NR NR PA FTGS FOR BRIDGES #2380,'#2352, - #2362/OKTO POUR PA Page 20f2 EsGil Corporation - In Partnership with Government for Building Safety I DATE: May 24, 2001 D APPLICANT JURISDICTION: Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 01-1036 SET: II ,•- .- • - PROJECT ADDRESS 2362 Hosp Way PROJECT NAME Pedestrian Bridge for the Grove Units 4 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes vQ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. -: The plans transmitted herewith have significant deficiencies identified on the enclosed check list -. and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. - The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to * - Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted Telephone # -' Date contacted (by ) Fax # Mail Telephone Fax In Person . REMARKS: Please see the attached minor outstanding correction. .' -By: Bert Domingo Enclosures: Esgil Corporation D GA El MB EJ PC 5/14/01 tmsmtl dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 CARLSBAD 01-1036 1. - 0n the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.3. . REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS PILES/CAISSONS , DESIGNER-SPECIFIED. • OTHER 4. • • .4. .• 2 When special inspection is required, the architect or engineer of record shall prepare an * inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form .4 J 4 * 4 . r 1 - . - C' EsGil Corporation In Partnership with government for !Buz&Izng Safety DATE March 30, 2001' C] APPLICANT JURISDICTION: Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO 01-1036 SET I PROJECT ADDRESS 2362 Hosp Way 'PROJECT NAME Pedestrian Bridge for the Grove Units The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes L , • The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck ± . The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. EI1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contabt person. - Th&appliàant's copy of the check list has been sent to: Wayne Fukuda 14661 MordRd., Ste. c, Tustin, CA 92708 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporätiôn staff did advise the applicant that the plan check has been completed. Person contacted Wayne FukudaTelephone # (714) 734-0466 "Z Date contacted 3 !?O(O (by l- ) Fax # (714) 734-0537 Mail \/'Telephonei./ Fax ,-/ in Person REMARKS Call David also Tel (619) 247-0380 By Bert Domingo Enclosures Esgil Corporation GA J MB EJ EJ PC 3/19/01 trnsmti dot . I 9320 Chesapeake Drive, Suite 208 • San Diego California 92123 • (858) 560-1468 • Fax (858) 560-1576 I. •., - • * - .• :. .: -Carlsbad 01-1036 March 30, 2001 PLAN REVIEW CORRECTION LIST MULTI-FAMILY FOREWORD (PLEASE READ): - This plan review is limited tothe technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws -. regulating energy conservation, noise attenuation and access for the disabled. This plan review - is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire -.. Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Pésent California law mandates that residential construction comply with Title 24 and the following model codes: 1997 UBC, 1997'UPC, 1997 UMC and 1996 NEC (all effective 7/1/99). - he above regulations apply to residential construction,regardless of the code editions adopted ordinance: . The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. - .:.To speed -up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Y•. '' • LIST NO. 16, R-1 GENERAL WITHOUT ENERGY OR POLICY SUPPLEMENTS (1997 UBC) rlforw.dot - •• Carlsbad 01-1036 March 30, 2001 GENERAL 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans • for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1 Deliver all corrected sets of plans and calculations/reports directly to the City of c - Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments . ••• . 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, r. . 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of - .. Carlsbad Building Department for routing to their Planning, Engineering and Fire - •. - - Departments. * ':- • NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by .5 . EsGil Corporation is complete. - . ADDITIONAL - - 2. - .Please submit calculations for the bridge girders. 3 Please show bridge floor loading 4. Sheet A 14 calls for 6X10 but different with the structural recommendations. Please clarify. -S 5.. 5. Sheet A 15 shows the caisson @ the sloping area 2' 1" but the calculations recommended minimum 3' Please clarify. :6. Page E2 of the calculations recommended base plates and anchor bolts but not -. shown on the details. Please clarify. - 7. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.3. - .•. 5 • . REQUIRED SPECIAL INSPECTIONS • •, • In addition to the regular inspections, the following checked items will also S • require Special Inspection in accordance with Sec. 1701 of the Uniform Building • Code. - - 'S • S - • ITEM REQUIRED? - 1 • PILES/CAISSONS S * DESIGNER-SPECIFIED OTHER S • • - .5 •-••- - REMARKS .-1S,S •; ,• Carlsbad 01-1036 March 30, 2001 8 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section - 4 106.3.5. Please complete the attached form To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate: . ' Yes U No U - The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake - - Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation Thank you - -5 S - - - -- *S - - - .5 .5 -. -- I -* - ' S - -.' . -- • • I_. ., S . is,, S •S • - . - S • , - , ._ - --, ;5' - 5__'__'_ .5 F -• - S S •L 5;•,. ,, -- . - -. 6ar1sbad01-1036 March 30, 2001 C ity of -Carlsbad Buil d i ng Department t BUILDING DEPARTMENT ---- - : . - 4 , NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans -- • ,• ., Plan Check No 01-1036 Job Address or Legal Description 2362 Hosp Way -Owner Address___________________________________________ '4 You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of - this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in-addition to the inspections normally required by the County Building / Code The Special Inspector is not authorized to inspect and approve any work other than that for which : 4he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that - -. he/she inspected and approved. The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the - • . items indicated on the reverse side of this sheet. (over) •- - -•• I -- •.• - Carlsbad 01-1036 March 30, 2001 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that, 1, or the architect/engineer of record, will be responsible for employing the special • inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction . project located at the site listed above. UBC Section 106.3.5. Signed 'I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above 4 • Engineers/Architects Seal & Signature Here - • e• S Signed I List of work requiring special inspection , . fl Soils Compliance Prior to Foundation Inspection fi Field Welding •. . Structural Concrete Over 2500 PSI fi High Strength Bolting fi Prestressed Concrete fi Expansion/Epoxy Anchors fi Structural Masonry fi Sprayed-On Fireproofing fi Designer Specified fi Other 2; Name(s) of, individual(s) or firm(s) responsible for the special inspections listed above: - 3. Duties of the special inspectors for the work listed above: ' ;•. 1 . Special inspectors shall check in with the city and present their credentials for approval prior to beginning work on the job site. S • • - Li Carlsbad 01-1036 March 30, 2001 VALUATION AND PLAN CHECK FEE. JURISDICTION: Carlsbad PLAN CHECK NO.: 01-1036 PREPARED BY: Bert Domingo DATE: March 30, 2001 .BUILDING ADDRESS: 2362 Hosp Way ,BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING - - PORTION •.i. AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE 'Jurisdiction Code cb By Ordinance 1994 UBC Building Permit Fee V 1994 UBC Plan Check Fee -- v Type of Review E complete Review U Structural Only - LI Repetitive Fee LI Other v Repeats El Hourly Hours * Esgul Plan Review Fee * Based on hourly rate I $326.811 $261 •I -: le 4 Comments at' 4 ,•'•' Sheet of I macvalue.doc - PLANNING/ENGINEERING APPROVALS S PERMIT NUMBER CB 01 -10i DATE ADDRESS LQ z p RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER S—Eci PLANNER DATE ENGINEER..<STh ' DATE_______________ DocS/MIStormS/PIannng Erwinéering ADDrovaIs • t -, -• 1111*1 - = ft1 411111 iiiiliL I c\_+O 50Me( r - - _ oil Cav- cpro OOck, - 11 SCc acrcO3 Ill - F HI + / . STRUCTURAL CALCULATIONS' 4• ? 4 For THE GROVE CONDOMINIUM LIGHT POLE BASE r44; - a * Prepared For e REALTY CONSTRUCTION Prepared By: •• •-. MOBAYED CONSULTING, GROUP 7940 Silverton Avenue, Suite 208 1 San Diego, CA 92126 (858) 586-7855 * FAX (858) 586-7845 PROJECT NO 02003-1.10 DATE ISSUED 01/23/2002 REVISION DATES _4 I I - • • ;---. I WMAMAlk Wi JOB 'JROV L:H—ro - MOBAYED CONSULTING GROUP . _L.. L CONSULTING STRUCTURAL ENGINEERS SHEET NO. OF___________________ 7940 SILVERTON AVENUE; STE. 208 CALCULATED BY______________________ DATE 1 1 - p a SAN DIEGO, CALIFORNIA 92126 TEL: (858) 586-7855 FAX: (858) 586-7845 CHECKED BY DATE ..• . .• P<-L 2Aç 7 ;1S ><)'çL ) o =: /L.,L,5 f7 H • ).L)! QL . -. . \•%ç 14 -f_fl 5C 4,A) '<- 2-• o , • • 0> : . . ••- d 4- .1 I . . - . - • • - ' • • . d - 3 Ljç zLd' bpr;. >L5'1.O". / / - • . • . • • SngieSel)2E5-I (Pddbi) I i Ot 1. 1 2002 9:1. : ELT (:)11ST,3 TO ::s: 004? / - Custom Lighting Fixture Sketch 4k Project ThGroveatHospWay Nv- Appllcatto!f Outdoor Lighting Fixture Type' iW and L1 Alternate Lighthig Materia1: Die Cast Aluminum and Tapered AJuminum Pole (Steel alternate) Pisb.: DtOreen . .' Lamp: (1) 250Watt Metal Halide I)nensioni:,35 pole • •• • : . •. p, :4 - D Liht1n 1Q21 - $&e& Office. Cerisjad, CA • • • • - .• \• (leQ) 720-$30; fIX. (78 ?40Q923 . • .•' fill ls.aptrn tapeed frQfl Iloyu1uninurs tbirag and is produpe • Tb tatnpur The per-ed t3 the orn diarret. a$t Rom. A365 Ulloy 1Iwrr.- r biae ii heit-treet,-J tc i is anchor base telescopes and is clreuisferanalIv bottom.. )p 121 g9lvanized pef ASIM steel rod having a mul• Igth of 55,000 PSI. round lug looted amed hundhole is tapped ruund mln 3 x50 or 'f reir. Coverqd hindhoi 'is the be&o. rvws, nim ørd bols arc &s aluminum cup is prvsdd pullS. d finish is brthd alum' 8iytIr powder 0eirit &no is avQilable. 356 nut covers shall te 1. 4011 anchor b19e unleas meL VrOd oIiVdL Ill ptICvI wrap - flift"d imed',tMy to orovin to 2 TN 1 Lc' 30141 : PELT ''HET E3 r _r O oct - a - - - p.JUL*INoNl INC Mill I C1 .12221 Y-111 P 102)002 . 0.101 flUUtW td1U MIWU1tIUflI to 40 Mounting RTA Ordering tnftlrmgtian; See page 187 V , TECHNICAL INFORMATION - PA tMl With 1.3 _______ Fell F.w.iTi °1T Featurts - tguloo MOVA 11eI site Th),-u, ICC l&.* Bell CiCIi uk ti el % $?iaft: Tht 11 Nw?,.bE VA V it V çlg.) ii3eil'l Ie5 IZI •i. -VA , lco 7.I4.10 114e113 (a 801m1119 603 Sa fl uN 7.4 2 1 l .Il4 ile3 1TAI ITA1 V ia4ilfl' X 7i1$%fl Gail I.j 1.Z LSI 1W .4 7.1 to lL 11-10 • I1.14 lit C Cori* t .. 1iiV4 10 ic+rnr Base -KTANN a 14A2cr LUI 3.1 U flUfl, the 'iCh • ,•i$ 21 1elo2ã1 t1 LI. 7 utol 14.2 Ill O.k 8.1 l Z0 0.V.I 11.12 106 44 Iz3*4 I2C . 1$ ccrdbon. 1 •' !TA 21 .1N 11.01 138 I.i I iso .e pole shot Z 7s4o1'E till 39 1.! 1'.I $1Il.1I!4 1*2Se r welded top or AU 00 X I IL1ae' 1.1 It LI 70 L3 1". • 11 ll. Cl 8eC4iiDS IT Is k 7j 1 112 e1;e TK Anchor Bolts: A15. Made 30 tCeie$ t Oil 40 110 VI I I4.IN-419 1e4 2Y, I - - .'- 1T*1 idi3Cl Ui.$a8ti1 t) . Li 4.1 2.3 1.0 III 11.10 %e4 mum yiei IkI - 0 1NIJ V 8.188 8. ILl L 1l-0 1.0 I I IS-li a88A4 1RI0* Do 311 I Greundliq: A -'- .- MAXIM a toss It 341' 4.19 11.0 131 I0.6 M I4.?t .II.lIt S O IV lt1ldB th • • rAI4 I . 01 V I.$suiflI 1il 1.1 3.8 31 ITt 11-iZ s014 I W bIt fb QVII1 i31oc S ;4.53flj 8 38 I 1Q4iI(11T GIN 01 7.11 1 0.1 10.* 1.1 01 MY 2 *1,4.11-Ill 1 AAAA I H.ndh.Ie A I I ISj 'Si IBillL.V!.15j?lIA8IL5l forced Rushed .•• . . M5r Nl#Pt, CMj p STD.C. 0 Hardware: All made of stain • • - 0øoart MC eq. i?tl..p. 9.$0, ••.-.- ', . Top Cap; Cad . Pole 0941 -. tor drill mount ' ,' hi; em ArClI0r WCiioeii h: Stundu 5 bisl lirr"It. pri$CIlQ9I VQVt lilt *flCI1Ur Ick ,1nDlit flUITS 0 t1Ofll ~DG A 9 C -dege6otion olstflo6oft A M ----- atlodlzad finis ¶ 1-11'r-1.117 %l/" AfimA I *011-0 1,45I83 Salt Covers; • •• 8 T t-10' 2.1/1' 50' AORTA4 A4 I.11r-11.L4 10.1/7 ARRTA.7 M*U• JJ533 ,,J%34 nclud*d with ; • r .i-to *44 A09 p.j5 oherise spi I0" 18-ul-Ie-;14-- • 4.I/T 14-1/T A0WtA-1 Null'. II ill are • -. 11TJ 1401t-I0' • • I 14.1, ABTA-4J WA N00c03 • . lrsisls dssu . •. • - • 14 OM Ins bllt..s 'u.'-v yt a ii puked 'd'iV 0iso to 9'*jy 5.45cr W.V. t opihd W4e,o ffi.ff 0$ c,i wiwn I5l's ersmll 710118. LI10$ISI$ I .ssy I714S el.;., r.- 'Ic0 a e pkaw.iqi c 1M 1 to LhSso4li lot,y Vlbritl$.o r w+,r,. 71 iitAwAzad w is iPtlV.q • • - 1 wit W%% owl 0,w,l r.mcw. 0ihtaI74 414X, , , .~ - • • . , 99 LI!Vib'WA T~ PE- P_ S f)/ / /5 II (Si Seels) 20S-i (Pd&d) ' - JOB714 1ROVE. . . 2MOO)%4)))jpM Lk1TP,L.€ MOBAYED CONSULTING GROUP -' m C CONSULTING STRUCTURAL ENGINEERS - SHEET NO. I OF___________________ -. 7940 SILVERTON AVENUE, STE, 208 CALCULATED BY DATE SAN DIEGO, CALIFORNIA 92126 .3 TEL (858) 586-7855 FAX (858) 586-7845 CHECKED BY DATE - 61 I E&A Engineers, Inc. Consulting Engineers 30 April 2001 . . .. . Response To Structural Plancheck Comments Project: Pedestrian Bridge For The Grove Units Plan Check No. 01 -1036 The following is the response to the structural comments. The item number corresponds to the plan check number. 1. Done. Please see the revised drawings. Done. Please see calculation sheets D-1 and D-3. pane: Please see calculation sheet C-3. Done. Sheet D-3 of the calculations calls for 6X1 0. 5 Done Please see sheet A-I 5 Done. Please see sheet A-16.'' Done. Please see notes on sheet A-9. • Sincerely, E&A Engineers, Inc Gil V Evangelista, PE, SE -2 • • II,'f",/I <A'\ llI II • - .. - - • • II 0 I , 11w I N 2422 i ((ct 6-30-0 ) - J ..,.i •• .• -• UC ...:: • - E&A Engineers,-Inc. Consulting Engineers : 1 -------------------- project: Pedestrian Bridge (7 Ft. X 22 Ft.) subject: Structural Calculations .O4/O1 Architect/ Client: The Renaissance COntinuum INDEX: GENERAL NOTES Al A2 KEY PLAN, DETAILS •:-j BI DEADLOAD : Cl FRAMING Dl 02 LATERAL El E2 MISC Fl '-: .. .tt•_. PEDESTRIAN BRIDGE GENERAL NOTES .' A. GENERAL . 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE UNIFORM BUILDING, CODE, 1997 EDITION AND THE APPLICABLE LOCAL CODES. L. 1.. 2. CONTRACTOR SHALL STUDY THE DRAWINGS, SPECIFICATIONS AND FIELD CON— DITIONS BEFORE SUBMITTING BIDS! COMMENCING WITH THE WORK INVOLVED. ANY DISCREPANCIES FOUND SHALL BE REPORTED TO THE ARCHITECT IN WRITING. ., '.. FOR CORRECTION OR CLARIFICATION; ' ALL DETAILS ARE TYPICAL. SIMILAR CONDITIONS REFER TO SIMILAR DETAILS. ITEMS! CONNECTIONS NECESSARY,TO CONSIDER THE PROJECT COMPLETE SHALL BE PART PART OF THE BID CONTINGENCIES. ' WALL AND CEILING COVERING UNLESS NOTED SHALL CONFORM TO CHAPTER 25 OF THE UNIFORM BUILDING CODE.' CONTRACTOR SHALL PROVIDE SHORING AND BRACING TO EXISTING STRUCTURE PRIOR TO ANY ALTERATION, DEMOUTION OR EXCAVATION. B. FOUNDATION FOUNDATION SITE PREPARATION, DESIGN, AND DATA SHALL BE AS PER UBC CHAPTER 18. ALLOWABLE BEARING PRESSURE 1000 PSF FILL AND BACK FILL SHALL BE COMPACTED TO A MINIMUM OF 90% DENSITY. C. LOADING CRITERIA 1. DEAD LOAD CALCULATED ' -2. LIVE. LOAD . FLOOR 100PSF ' ,: r 3 WINDLOAD V= 70 MPH EXPOSURE C 4 SEISMIC LOAD ZONE 4 Ca= 44 Na, Na= 1 3 0 CONCRETE WORK SHALL CONFORM TO ACI 301-72,318-83 & 315-80 4 CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE A MINIMUM OF 2500 PSI. HOWEVER NOTE'THAT ONLY 2000 PSI IS USED IN THE DESIGN SO THAT CONTINUOUS INSPECTION NEED NOT BE REQUIRED. d%t MIN. CONCRETE PROTECTION FOR REINF:sTEEL' . SLAB ON GRADE 2 1. CONC. POURED AGAINST EARTH e43I$ :• ' OTHERS AS PER ACI 318, CHARTER 7.` . . E. REINFORCING STEEL ALL REINFORCING BAR SHALL CONFORM TO ASTM A615 DEFORMED GRADE 40. .F.. STRUCTURAL STEEL , ALL AMATERIALS , WORKSMANSHIP AND MIN. REQUIREMENTS SHALL BE IN ",*,ACCORDANCE WITH THE LATEST REVISEDEDITION OF THE AISV MANUAL OF STEEL CONSTRUCTION ALL STRUCTURAL STEEL SHAPE SHALL CONFORM TO ASTM A36, FY= 36 KSI STRUCTURAL TUBING SHALL CONFORMJFO'ASTM A500, GRADE B,FY=46 KSI. . SUBMIT STEEL SHOP DRRAWINGS FOR REVIEW: . , ":... • I EG WOOD - ALL FRAMING LUMBER SHALL BE DOUGLAS FIR• • - FB=875 PSI FV= 95 PSI FOR 2X MEMBERS OF #2' FB=1150 PSI FV=95 PSI FOR 4X MEMBERSDF #1 • FB1350PSI FV85PSI FOR 6XBEAMSDF;#1 - H t•' ,', I i..' i••4_•. 1••,• '•- •• I, ALL WOOD IN CONTACT WITH CONCRETE SHALL BE TREATED.' PLYWOOD SHEATHING SHALL BE STRUCT I EXTERIOR TYPE UNLESS NOTED OTHERWISE. INSPECTION APPROVAL IS REQUIRED PRIOR TO COVERING THE SHEATHINGS. . MIN. NAILING SHALL BEAS PER UBC TABLE NO. 23-I1-B-1. WOOD CONNECTORS DESIGNATIONS INDICATED REFER. TO STRONG TIE CONNECTORS AS MANUFACTURED BY SIMPSON COMPANY. OTHER CONNECTORS HAVING EQUIVALENT CAPACITY MAY BE USED. USE STANDARD CONNECTORS WHENEVER APPLICABLE. USE APPLICABLE JOIST/BEAM HANGERS FOR JOIST TO BEAM AND BEAM TO ' BEAM, COLUMN CAP CONNECTORS FOR BEAM TO POST AND POST BASE ' ' CONNECTORS FOR POSTS. H. EXISTING UTILITIES ' UTILITY LINES AND ACCESSORIES INDICATED ON THE DRAWINGS OR FOUND AT THE SITE THAT INTERFERE WITH THE NEW CONSTRUCTION SHALL BE RELOCATED AS NECESSARY. . THE CONTRACTOR SHALL OBTAIN ANY BUILDING PERMIT REQUIRED. THE CONTRACTOR SHALL ALSO PROVIDE AND GET APPROVAL OF ANY DRAWINGS AND DATA REQUIRED TO OBTAIN CITY APPROVAL FOR THE RELOCATION. , . ..... •'.F' t'' F '., , f., 4' t 4',.' ",• ' - ' • '., F' , • '. '-'-:. . .;, . • • ., • DEAD LOADS. ROOF . FLOOR • 6PSF '. P.W. 'I. 2 PSF FRAMING . 3 PSF CEILING + MISC 9 PSF 20 PSF • • . .- 1 - •..i. - -- . -. *4 4 I .4,' - 4' • 4, -• • . - 4 .• .. 4 . 4 - -''- •. ,.•,,. •. . , •"t_' - -- -S B project: / Comments Sheet No. i E&A ENGINEERS dale: Consulting Engineers deslyned by: Jr it 8. (gi) L t F 'I I 1- k ,k • / •• - -., II -. I - . Ct 1 -••-• 20505 E. Valley Blvd, SuIte 108, Walnut, CA 91789 • irifinri cn cnic non cn ococ . . '• Y CANTILEVER BEAM DESIGN e&a engineers .Project: PEDESTRIAN BRIDGE Membr: J 1 "ALLOW STRESSES ••. SPAN LENGTHS ' Fb . 0.875 KSI CENTER SPAN 6.67 FT Fv 0.095 KSI LEFT CANT. 0 FT E 1600 KSI RIGHT CANT . 0 FT 'I. F.= 1.067 . CF= 1.1 . Cm= 0.97 for b=<4 Cr_ 1 Croof= LOADINGS . ,UNIFORM . . CONCENTRATED LOADS (KIPS) . .. . ' CENTER SPAN ,. #1 . #2 'UNIFORM DL -20 PSF DLP 0 0 ' UNIF.LL . 100 PSF . LLP 0 0 ,;TRIBWIDTH • 1.33 FT . X 0 0 LEFT CANTILEVER . . :UNIF DL •: •' . 0 PSF . DLP . 0 0 UNIF LL ,' 0 PSF LL . 0 0 ..TRIBWID11-1 . OFT X 0 0 RIGHT CANTILEVER . . •:'' . UNIFORM DL . 0 PSF . . DLP 0 0 UNIF LL ' •. 0 PSF LL P 0 0 TRIBWID1H . . . . 0 FT X 0 0 DESIGN MOMENTS AND SHEAR (PATTERN LOADING) - . .POS MOMENT 0.89 •,'. . MAX MOM 0.89 .. LEFTNEG3MENT 0.00 REQDS 11.41 RIGHT NEG MOMENT ' 0.00 . CENTER SPAN . CANTILEVER REACTIONS SHEARATLEFT 0.53 . . 0.00 0.532266 .SHEARATRIGHT , . ,' 0.53 • 0.00 0.532266 0.53 0.00 :- DESIGN SHEAR 0.53 •''. atddist 0.46 q'.-'. ... . H.t. •-' •" . - . ,TRIALSBTION: . • -TRIAL . B= . 1.5 FLEXURE REQUIRED d= . • 6.76 - SHEAR REQUIRED d 4.54. SELECT . B . • 1.5 I 47.6 d 725 79 DEFLECTION CHECK • CENTER SPAN • CANTILEVER LEFT RIGHT DLDEFL - 001 000 000 • J LLDEFL • . , . 0.08. •' 0.00 . ' 0.00 . :LL+DL s - 0.09 . . 0,00 . 0.00 ALLOWABLE DEFL .LL(LJ36O) '• • 0.22 .t4,LL+DL(L/240) 033 NOTE-CHANGE SIZES IF ALLOW DEFL ARE EXCEEDED. 4 - - . •1' . - . ...................... ......... - •. .. . ". 0.00 • 0.00 0.00 0.00 e&aengirieers Project: : PEDESTIAN BRIDGE Member: B V V V V ALLOW STRESSES V SPAN LENGTHS • 1.35 KSI CENTER SPAN V 10.33 FT Fv V 0.085 KSI '' . LEFT CANT 6 FT .'E 1600 KSI ' RIGHT CANT V 6 FT ''I.F;V 1 CF= 1 Cm= 1 for b=<4 V Cr=. V 1 Croof= 1 PJ V V V V V LOADINGS UNIFORM V . CONCENTRATED LOADS (KIPS) CENTER SPAN '. #1 #2 ;10 UNIFORM DL, wi . 20 PSF ' DL P 0 'UNIFLL,w2 100 PSF 'V 4.*..LL 0 ..VTRIBWJDTH ' 3.67 FT V X 0 . LEFT CANTILEVER V V V .' UNIF DL,w3 20 PSF' V DL P 0 ;'UNIFLL,w4 100 PSF LL . 0 TRIB WIDTH V , 3.67 FT . 4;,. X V 0 V ' V RIGHT CANTILEVER V UNIFORM DL,w5 20 PSF DL P V 0 V UNIF LL,w6 100 PSF LL P . 0 TRIB 'MOTH 3.67 FT , X 0 DESIGN MOMENTS AND SHEAR V (PATTERN LOADING) kft 0 0 :. 0 0 0 0 0 0 0 V POS MOMENT, Mc 4.55 MAX MOM 7.93 k ft LEFT NEG MOMENT, MI 7.93 REQD S . 70.46 in"3 RIGHT NEG MOMENT, Mr 7.93 CENTER SPAN CANTILEVER REACTIONS ,• SHEAR AT LEFT, VI 2.27 2.64 '. .. 4.917066 V V SHEAR AT RIGHT, Vr 2.27' - ' 2.64 4.917066 2.27 .: ' 2.64 • DESIGN SHEAR, V 2.64 atddist 255 i TRIAL SECTION t TRIAL B= ." 5.5 in '':':, V actual fb= 0.660 KSI V 'FLEXURE REQUIRED, db= (6Mc/(bFb)" , a.77'in , actual fv= 0.076 KSI SHEAR REQUIRED dv= 1 .5V/(bFv) - .'8.48 in ; SELECT B 55 in 7 1= 3930 IN "4 D -951n, S= 831N"3 -V I JI ._•OVtt...VtV ,.Vt '-DEFLECTlON CHECK CENTER SPAN • , . CANTILEVER V in. '- LEFT RIGHT ' DLDEFL 001 005 005 "ALLDEFL 010 054 054 0.11 . . 059 0.59 VI , .ALLOWABLEDEFL LL(L/360) . 0.34 LL -' , 0.40 0.40 + DL (Lf240) 0.52 , -' - 060 060 ,.. NOTE: CHANGE SIZES IF ALLOW DEFL ARE EXCEEDED . VI VVFORMULAS: . V VI=(wl+w2)L/2 + P1(L—xl)/L +P2(L—)/L . fb= Mc/S Vr= P1+P2+(w1-i-w2)L--VI . . f'/ 1.5V/BD 'Mc= (wl+w2) L"2/8 +P1 (02) +P2(x2/2)— (MdI—Mdr)/2' MdI=w3x"213 +Pdlxl +Pd2x2 Mdr=w6x"2/3 +Pdlxl +Pd2x2 , MI= (w3+w4)x" 2/2 +P1x1 +P2x2 ti Mr= (w5+v6)x" 2/2 +P1x1 +P2x2 , VI=(w1+w2)L/2 +P1(L—xl/L) +P2(L—/L) i I Vr= PI +P2+ (wl+w2)L—VI ' 2 1' • J i - . V. • - V • V V;' - J ' ' - project: /-, A Comments- Sheet No. E&A ENGINEERS date: Consulting Engineers deskineJ I 0 0 14. , t\) I ( 0 • T P-- ,..- 'l64 () f7t /c o __ / .. 0 •, 00 • . 0 • 4 ••- • 0 0 *0.• .• ••,. .. . '. . S - -•.. . 000 • 0 •• ! : •'-• I •• 20505 E. Valley Blvd. Suite 1108, Watniit, CA 917B9 0 . II nnn cnn cnic f nnn rn nnc E&A ENGINEERS, INC. FSCOL R.97 > project PEDESTRIAN BRIDGE • mark TYP TS/ FOOTING FOOTING DATA: DL= 1 kip > LATERAL SOIL BEARING: > P= 0.44 kip . 200% increase per footnote 4 h= 8 ft UBC Table 18-I-A .> Fy= • 46 ksi > E= 29000 ksi Dm=.025h 1.2 in Dm- Max Inelastic Response displacement R= 2.2 Os- Design Level Response displacement Ds= DmI.7R 0.779 frame factorc=. 't M= Phc+DrnDL 3.58 k-ft M- includes P Delta (DmDL) • Reqd 5= ML66Fy = 1.42 lN'3 Reqd 1= P (h c)A3Y(3Ds)E)= . 5.74 lNM > USE: Its 4x4x3116 , > J= •. 6.59 lNA4 >S= 33INA3 • embedment: 1.5 ft -' Footing: diameter,B 2.5 ft depth,D 3.08 ft Vertical reinf. 3.53 i&'2. Base Plate: bp= 16 dp= ' 16 EMBED COLUMN TO FOOTING Le= 2 FT .• `10 in fc. . 0.00 ksi Fp= .351'c '0.700 ksi - BASE PLATE: • , . '. -. DL+LL DL= 1 47 kip LL= 423 kip - ' fp=(TlJAp)= ' -. '0.035. ksi tp=2n(fpffy)A5 1,0.187 in 9DL+E114 4-314"dia.x12"A.B., / > d= 13in > bp .16 in .,' T=M/d-.9011 J.19, kips mpt= 090 in-kip ••:. . tp= 0.34 in - -FOOTING: Clalculations per UBC 97 1806.8.2 ' NON-CONSTRAINED CONSTRAINED • B= • • 2.5 ft -• 2.5 ft A= 2.34P1(sl b) trial D= 308 It 48 0= N2(1+(1+4 36h!A)' 5) 8= 05 v • sl= 0.51 '. ' 0.80 • 0= (4.25(ph!s3B))'.5 s3= 154 2.40 A •. 0.80 - .• • . cal D 308 158 b • C' 0.25 RAILING E&A Engineers PROJECT:: BLANEY * : .• RAILING/ HANDRAIL DESIGN PER UBC TABLE 16—B HANDRAIL= 200 LBS AT ANY DIRECTION RAILINGS AND GUARDRAIL CASE 1 50 PLF FOR EXITS SERVING GREATER THAN 50 OCCUPANT LOAD . CASE 2 20 PLF FOR OTHERS >CASE 2 LOAD 20 PLF . wood steel >RAILING POST SPACING, L= . 6 FT. RAILING >HEIGHTH= 3.5 FT' M=PL/4 300 300 FTLBS • > POST M—_ .420 FTLBS M=2/8 90.0 90 FTLBS Railing S= 3.130434783 0.166666667 in'3 RAILING POSTS SPECS • . p 3 L / / i 1 • WOOD — ALT I • STEEL ALT-11 PIPE ALT III Fy=46 li Fy= 36 ksi Fb(KSI) 1.15 27.6 21.6 0.233 OF_SSi0 SM/Fb 4.383 . 0.183 4. Nc TRIAL SIZE WOOD . • TUBE • Pipe Lu width ordiaB= 3.5 1.5 l mCD _ wood depth= 3.5 1.5 0.125 • - -30-0 * * ThK= . - 7 . 7.146 '. . 0.165 - S•>• adopt • .• . (hi Pita • base Side conn steel Plate BASE Pipe Properties t dia(in) S(in"3) bolt spacing(in) 45 3 in 1 0.133 Bolt.Tension(Ibs) 93.33333333 140 lbs 11/4 0.235 Plate (b=4') - 210 inIbs 11/2 0.326 S Plate (in" 3) - . . • 0.008 in3 2 0.561 Plate thk(in) - • 0.108 in 21/2 1.06 .•• - ,• • . ) • •:. It 1 --- BRIDGE REPAIR 4 c ; TO a 012080 1' • •: Z# IEW Og 2362 HOSP WAY COVER SHEET A16 DETAIL - BRIDGE FOOTING A2 SCOPE OF WORK All DETAIL - BRIDGE SUPPORT COL A3 SECTiON 01000 - GENERAL NOTES Al 8 DETAIL - BRIDGE JST TO BM A4 SECTION 01000 - GENERAL NOTES A19 DETAIL - HANDRAIL ANCHOR A5 SECTION 01000 - GENERAL NOTES A20 DETAIL - BRIDGE TO WALL A6 SECTION 06100 - FRAMING NOTES A21 DETAIL - BRIDGE @ THRESHOLD A7. SECTION 06100 - FRAMING NOTES A22 DETAIL - BRIDGE DRAINAGE A8 SECTION 06100 - FRAMING NOTES A23 DETAIL - RAFT TO BM A9 * SECTION 06100- FRAMING NOTES A24 DETAIL - RAFT TO LEDGER A10 SECTION 07600 - FLASHING NOTES A25 DETAIL - EAVE All SITE PLAN A26 DETAIL - CONFINED RIDGE Al2 BRIDGE PLAN A27 DETAIL - WOW @ CONFINED RIDGE : A13 FOUNDATION PLAN A28 DETAIL - ROOFING AT RAKE A14 SECTION - LATERAL A29 DETAIL - DECK FLASHING Al-5-7 SECTION - LONGITUDINAL • COVER SHEET SoIe Title • Engineering Provdngs for: Ion rmfo The Rnotssone Continuum The ('rove Units • 11 4661 Mford Rood, Suite C Ovtners Association $ • 7ustln, Calif. 121 Hosp 05 El Nay at Camino Real C>32 Al rn4134046 FAX 14.0551 Carlsbad, CA '; • 4 os,oe,oi RevIIon9 SA G*d SFD Sheet No. 5(~C F*E OF - -V 01z;Z< '. I. REMOVE ROOF ELEMENT. 2. DISCONNECT ELECTRIC AL UGHT - - V AND CONDUIT. V 5. CAREFULLY REMOVE TOP REAILING SYSTEM MILL BE REINSTALLED) ..•. DEMOLISH EXISTING DECK SYSTEM. INSPECT EXISTING SEAM TO FOUNDATION V CONNECTION AT PARKING LOT. CONTACT I V • ARCHITECT NITH INFORMATION. V V V 6., INSPECT EXISTING FRAMING FOR DRY ROT AND/OR TERMITE DAMAGE (INCLUDING V • V BUILDING V4ALL). r -7. V VCONSUC.T NEY4 DECK FRAMING. V V REBUILD EXISTING ROOF ELEMENT AND RAILING V INSTALL DRAINAGE 1 0.-, APPLY "LIFE DECK" COATING SYSTEM V V V V PER MANUFACTURERS SPECIFICATIONS. 7 -I I.. . APPLY BUILDING PAPER, AND LATH V PLASTER (COLOR SHALL MATCH EXISTING) V • • (PROTECT DECK COATING) V VI2. RE-CONNECT LIGHT FIXTURES. IS.- CLEAN-UP AND REMOVE ALL DEBRIS. Title,V OF V4ORK V Engineering roir1gs for: The RenoissonGe Conttnum • The Grove Units -14661 Myford Rood, Suite C. 0v4ner5 Association 268 Hasp kMoy at El Comma V - V Real . .1I4.154.04 FAX ,-754.055-7 Carlsbad, CA Scale: Dat. 03/OS/OF Revisions Ghkd SFV PH. Sheet No. SECTION 01000 - GENERAL I. ALL V4ORK SHALL COMPLY k4ITN APPLICABLE STATE, COUNTY, AND CITY ORDINANCES AND THE ii UNIFORM BUILD CODE, 1 UNIFORM BUILDIN6 COPE STANDARDS, I1 UNIFORM MECHANICAL COPE, I1 UNIFORM PLUMSIN COPE, AND THE I NATIONAL ELECTRICAL CODE. 2: THE GENERAL BUILDIN6 PERMIT AND PLAN CHECK SHALL BE PAID FOR AND OBTAINED BY THE CONTRACTOR. ALL H OTHER PERMITS SHALL BE PAID FOR AND OBTAINED BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE FOR THEIR PORTION OF THE VORK. S. NO 5US5TI11JTION5 V4ILL BE MADE V4ITHOUT THE Ok14NER'5 PRIOR V4RITTEN APPROVAL. 4. THE OVNER MAY ORDER EXTRA V4ORK OR MAKE C.HANES BY ALTERIN&, ADDINS TO, OR DEDUCTIN& FROM THE V4ORK. THE CONTRACT SUM BEING ADJUSTED ACCORPINLY. 5.: 'THE INTENTION OF THESE PROJECT DOCUMENTS IS TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, AND TRANSPORTATION NECESSARY FOR COMPLETE AND 'PROPER EXECUTION OF THE k440RK. s.,. THE ARCHITECT DOES NOT VARRANT NOR GUARANTEE, -EITHER EXPRESSED OR IMPLIED, ANY PRODUCT THAT HAS , SEEN MENTIONED OR IDENTIFIED BY ThEIR TRADE NAME IN THESE PROJECT DOCUMENTS. 7• ALL TRADES SHALL FURNISH ALL LABOR, EQUIPMENT; MATREIALS, AND PERFORM ALL kMORK NECESSARY, INDICATED, REASONBLY INFERRED, OR REQUIRED BY ANY BUILDIN AMP/OR SAFETY CODE V4ITH JURISDICTION TO '-COMPLETE THEIR SCOPE OF AORK FOR A COMPLETE AND PROPERLY FINISHED JOB. re0t_GENERAL_NOi ES - Engineering Prcii.'tirs for: The genoisnG, ContInuum The crove Units II Myord Rood, suite - Oviners Association -• Tutin, C.oIiP. c12105 '-,114. '754.0466 - FAX 14O551 Hasp Va at El Camino Real Carlsbad, CA le: Pot. o/Oe/oI R.evIIons PrtMn SA/SPP Ghkd PH, Sheet No. SECTION 01000 - GENERAL CONT. S. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUILDING LIMES AND LEVELS. THE CONTRACTOR SHALL COMPARE CAREFULLY THE LINES AND LEVELS SHOMN ON THE PROJECT DOCUMENTS kITH EXISTING LEVELS FOR THE LOCATION AND CONSTRUCTION OF THE V0RK. ANY DISCREPANCIES IN THE PROJECT DOCUMENTS, DISCREPANCIES BETkA1EEN EXISTING STRUCTURES AND PROPOSED 'MORK, OR DISCREPANCIES BETI'MEEN PROJECT DOCUMENTS AND EXISTING STRUCTURES SHALL BE BR0UHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCING NITH ANY IMORK. q: ALL TRADES SHALL DO THEIR O4N CUTTING, FITTING, PATCHING, ETC., TO MAKE THE SEVERAL PARTS OF THEIR V4ORK AND OTHER TRADES' kNORK TO PROPERLY FIT TOGETHER. 10. ALL TRADES l'MILL, AT ALL. TIMES, KEEP THE PROJECT, AND THE PROJECT SITE FREE FROM THE ACCUMULATION OF - - I'MASTE MATERIALS AND RUBBISH CAUSED BY THEIR Y4ORK. AT THE COMPLETION OF THE PROJECT REMOVE ALL RUBBISH, TOOLS, SCAFFOLDING, AND SURPLUS MATERIALS AND LEAVE THE JOB IN A BROOM CLEAN CONDITION. II.- BEFORE SUBMITTING A BID, BIDDERS SHOULD CAREFULLY • - EXAMINE THE PROJECT DOCUMENTS, VISIT THE SITE OF THE MORK AND FULLY INFORM THEMSELVES AS TO ALL ' EX15TIN& CONDITIONS AND LIMITATIONS. - . .. ENERAL NOTES C.ONT Title Engineering Drov4ings for: ThORnoissnc. Continuum The crove Units 4.. i or Suite • Oviners Association TL)stlfl, Calif. c12708 Ho5p Noy at El Camino Real -74:754.0466 - •PAX154.0551 CorI9bod, CA SECTION 01000 - GENERAL CONT. 12. THE PROJECT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERV4ISE SHO4N, THEY P0 NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR, HILL SUPERVISE AND DIRECT THE NORK AND HE V4ILL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS OF THE NORK BY THE ARCHITECT V4ILL NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES REQUIRED FOR THE V4ORK, kNHICH IS THE RESPONSIBILITY OF THE CONTRACTOR. ANY SUPPORT SERVICES PERFORMED BY THE ARCHITECT V4ILL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED INSPECTION.SERVICES ?'4HICH ARE FURNISHED BY OTHERS THESE SUPPORT SERVICES PERFORMED BY THE ARCHITECT, V4f4EThER OF MATERIAL OR NORK, AMP kMHETHER PERFORMEP PRIOR TO, DURIIN6 OR AFTER COMPLETION OF CONSTRUCTION ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AMP IN .ACHIEVIN& CONFORMANCE AITH THE PROJECT 'DOCUMENTS, BUT THEY P0 NOT GUARANTEE THE CONTRACTORS PERFORMANCE AND 'NILL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. 5 :ftj OMISSIONS OR CONFLICTS BET1EEN THE VARIOUS ELEMENTS OF THE PROJECT DOCUMENTS MILL BE SROUHT TO THE ATTENTION OF THE ARCHITECT BEFORE .PROCEEPIN 'MITH ANY VORI( SO INVOLVED. :? &NERAL NOTES CONT Scale: The Renaissance Continuum 14661 MyPord Road, Suite Tustin, Calif. 012-705 FAX 134.0531 I4.4.04'I Engineering PrIri for: The crove Units Oners Asso.ition Hosp V'4oj at El Camino Real Carlsbad, CA ReVt5ton5 Dot. 03/05l0 I Sheet No. A5 UI I1 0 z 0 c3 0 o FH • I - - - - .• , -.• $ .• ,- ; ? t I - -. - - - •? .-.• - - I.. * 4 : :- ,1 - U) t) • - 4 • - 4-- * -• LI33IItTI I -1fl1LZ11Z --Z>'33>L - - Irnr - nii cYni> >ni0''X00O0 'O ->3:z0 !LL - __ • _ <--i3-jI .flr3 - _ >O •jj> -143 --4 •oZfl13 Iu 0 I11> U' zj ZUS . x >- I 0Jjrn jJn1>> z>> r>nl r> tU1Ii_Z fl':1: )zZ .Zrj1 n10 -0tUjI0--j xF - U q j0J 33fl1 li -u •fl1çj Z nj * rn41'11 OX' "- XO c-i-j -fllr cz •>cJ5j .ln z _au' C' • Z (~3 i1;O Znl>-fl-I Izxi3:iL)ox 0 'hr -> -• 00 ii:) OZO r3ni 'ZJ0 °0 o4rtIQ u r-j L3A30 11 ç bO Lp 0- b Tfl\3 o4 1 ZF041OUL. or0-(1 O?co "3 Z(S> I1l Zis irr co>fll3> '33> flu> C' > (\ll I (P 2 F -o - C' 00 rFUIoOtii> uj Lo Ut 3 1> A > A Am i1j-' 0 Ozr 111 UI U' >1 1 0Unu flu I 1fl1 Oflhl -I1U'fll - - o UI0fl1z1 Zr (' t 11 'hUI ' - r 4 SECTION 06100 - FRAMING CONT ROOF SHEATHING - 1/2" CDX PLVOOP (P.S.R. 24/0) kA4ITH Sd AT 6 INCHES O.C., SOUNDAR'r NAILING (SN) Sd AT 6 INCHES O.C., EDGE NAILING (EN) 5d ,AT 12 INCHES 0.C.,FIELD NAILING ALL EDGES BLOCKED (ALT: PL"i'k'4OOP EDGE CLIPS). S. FLOOR SHEATHING - 5/5" CDX TG PLYI'MOOD (P.S.R. 32/1(o) kMITH lOd ATS INCHES 0.C., BOUNDARY NAILING (SN) I0 AT 6 INCHES 0.C., EDGE NAILING (EN) lOd AT 10 INCHES 0.C., FIELD NAILING ALL EDGES BLOCKED (ALT: TONGUE-AND-(5ROOVE 'JOINTS) GLUE AND NAIL PLYY'400D FLOOR SHEATHING TO ALL POINTS OF SEARING. 10. THE BUILDING DEPARTMENT SHALL BE NOTIFIED FOR INSPECTION OF, ALL FLOOR AND ROOF DIAPHRAGM NAILING, SHEAR I"MALL NAILING, AND ALL SHEAR CONNECTIONS PRIOR TO CONCEALING NAILING. FIRESTOPPING SHALL BE ROVIDED IN THE FOLLOIMING 'LOCATIONS: 20.1 IN CONCEALED SPACES OF STUD INALL5 AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS ALONG THE LENGTH OF THE 'MALL. 4 20.2, AT ALL INTERCONNECTIONS SETk#.4EEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, PROP CEILINGS, AND COVE CEILING. Title FRAMING NOTES CONT Engineering Droings Per: The Renaissance Continuum-he.Grove Units 14661 MyPdrd Rood, Suite C. Ovtners Association ' '• 'Tut, CoIIP. 2108 kosp Noy ot El Comino R&cI rn4.154.0466 FAX 134.0551 • Corl5bod, CA .' ' * 'S - P," O3/O/OI RevIsIori ______ Prp,n SAJSPP Sheet No. A7 SECTION O'IOO - FRAMING CONT 20.3 IN CONCEALED SPACES BETkALEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BET1EEN STUDS ALONG AND IN LINE V4ITH THE RUN OF STAIRS THE HALLS UNDER THE STAIRS ARE UNFINISHED. 20.4 IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS k*4HICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, V'4ITH NONCOMBUSTIBLE MATERIALS. II. FIRESTOPPING SHALL CONSIST OF NOMINAL 2 INCH LUMBER, EXCEPT FOR OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS VHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS INHICH SHALL USE MINERAL kOOL. 12. NOTCHING OF BEAM6 IS NOT PERMITTED UNDER ANY CIRCUMSTANCES. IS. A HOLE NOT GREATER IN DIAMETER THAN 40 PERCENT OF THE STUD kMIDTH MAY BE BORED IN ANY VOOD STUD. BORED HOLES NOT GREATER THAN bO PERCENT OF THE V4IDTH OF THE STUD ARE PERMITTED IN NONBEARING PARTITIONS OR IN ANY V4ALL INHERE EACH BORED STUD IS DOUBLED, PROVIDED NOT MORE THAN TV4O SUCH 1 'SUCCESSIVE DOUBLED STUDS ARE BORED. IN NO CASE SHALL THE EDGE OF THE BORED HOLE BE NEARER THAN 5/5 INCH TO THE EDGE OF THE STUD. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF SUP AS A CUT OR NOTCH. Sheet FRAMING NOTES CONTTitle SGOIC: Enginóering Pravdrs for: Pat& OS/OS/OI The Renaissance Continuum m. drove Units _____ u., S'VSFD 14661 -Mg Rood, Suite . ' Ov4ners Associotlori Sheet No. Tutin Calif. 412'705 Hosp Yiay at El Camino Real '714.754.0466 A8 ______ FAX 14.O531' Carlsbad, CA 5r-010: Pat. 05/0/0I RevIsIons Prn SA/SP SPP PLN OW GC 4O/OI Sheet No. ' - SECTION 06100 FRAMING CONT 4. SOLID 5AY4N RECTANGULAR LUMBER BEAMS, RAFTERS, AND JOISTS SHALL BE SUPPORTED LATERALLX TO PREVENT ROTATION OR LATERAL DISPLACEMENT IN ACCORDANCE kMITH THE FOLLOV4IN: IF THE RATIO OF DEPTH TO THICKNESS, BASED ON NOMINAL - DIMENSIONS,IS: -A. 2 TO. I, NO LATERAL SUPPORT IS REQUIRED. 5. 3 TO I OR 4 TO I, THE ENDS SHALL BE HELD IN POSITION, AS BY FULL DEPTH SOLID BLOCKING, .--- BRIDIN, NAILING OR BOLTING TO OTHER FRAMING MEMBERS, APPROVED METAL HANGERS OR OTHER ACCEPTABLE MEANS. S TO I, ONE EDGE SHALL BE HELD IN LINE FOR ITS • ENTIRE LENGTH. -. D. TO I, ERID&IN, FULL DEPTH SOLID BLOCKING OR CROSS BRACIN6 SHALL BE INSTALLED AT INTERVALS NOT EXCEEDING S FEET UNLESS BOTH EDGES ARE HELD IN LINE. E 1 TO I, BOTH EDGES SHALL BE HELD IN LINE FOR THEIR ENTIRE LENTF4. ROOF TRUSSES SHALL BE SUPPORTED LATERALLY AT POINTS OF BEARING BY SOLID BLOCKING TO PREVENT -ROTATION AND LATERAL D15PLACEMENT. ITEM .• - •. . REQUIRED REMARKS STRUC. CONC. - 2,500 p51 YES MA Sheet FRAMING NOTES C.ONT Title Engineering Dravilngs for: The Renolssonc.e Continuum The Grove units I4I Myford Rood Suite C OP'4ner5 Association Tustin, Coll! 205 Hosp at El Camino Real - 714.734.04 FAX 154:0551 . Corlsbod, CA .. - ,•••._.- SECTION O1OO - FLASHING .1. ALL. FLASHING SHALL BE 26 6AU6E, 6ALVANIZED IRON SHEET METAL. 2. ALL ROOF PENETRATIONS SHALL BE PROPERLY FLASHED. AMP/OR COUNTERFLASHEP TO PREVENT V4ATER FROM PENETRATIN& TO THE INTERIOR OF THE STRUCTURE. 3. FLASH ALL EXTERIOR OPENIN&S AND ROOF TO k4ALL JOINTS. 4. VERTICAL EXTERIOR OENINS (DOORS, Y4INPOV4S ETC.) SHALL BE FLASHED BOTTOM, SIDES, AND TOP .V41Th 'MATERPROOF KRAFT PAPER. EACH BOTTOM, SIDES, AND TOP KRAFT PAPER FLA5HIN6 SHALL BE A CONTINUOUS, FULL LENGTH PIECE. POOR OPENINGS SHALL HAVE AN ADDITIONAL METAL : FLA5HIN& Y4ITH DRIP ABOVE. 4 1• A t V. Sheet FLASHING NOTES SIe: The R oIssnc,e Continuum 1,466 1. MyPord Road, Tustin, Calif. 2105 V V V• FAX 4.051 V 1I4.134.046 A10' Engineering Dravilngs for: wrove Onsrs Asso ciation Hasp V4ay at El Camino Real Carlsbad CA Poe. o/o/OI Chkd SFP FNI No. V V .I1IIII,,u Niglio SITE FLAN The Renalssanco'continuum ~En gineeringI1'12'1Ii j--i. The C-7rove Units ___ Oviners Rr-si TUstin, Calif. 41:2105 JI 7 - - MATCH <I9N5 4xbSM. EXPAMON.Rr s_-0 -_ - i F A A14 14 DEMO EX MK AALL 4x6 RAFT - x. - -- - Sheet - -- 4 - - -. Title RIE ELAN SccIe: " Engineering Drolngs for: Raylislons Data 03/08/01 The Renaissance Gofltlnuurn The Grove Units CP*4SPP - 146I Mford Oners Association - Sheet No. Tustin, Oplif. 012105 Hasp Mcj at El Camino Real 714.134.046 Al 2 FAX 54.051 Carlsbad, CA bxlO DM9 / ^16 All I.. - . (4) PM P1! GaL - - - ro poj FT cl IS F- - -i- - It2' T 51-51 21-01/2" P TGH XIS - Title FOUNPATION ELAN Engineering DrviIng9 for: Pot. o,oeioi The Renoisnc.e ContInuum The rove units ReVISIOnS SPP/SA 4661 ford , 0v4ner5 Association sPp Tustin, Collf. 21O Sheet No. Hop 1610 at El c.omirio Real 714.754.0466 Al 3 - FAX 14057 C.0r13bod, CA -- Ix tO TRIM H \ IxTRIM 11/2 IE @ 4'-' f1!2" PLOO (EA. SIDE) - 1/S STUC.C.O (riP) z PEBBLE EPDXY N I I/2" P.C. @42" in 5'(5TEM 2 x S STUPS @ 2" 4 -, "LIFE DEC K" / O.C. •-• OR EQUAL / \ 3/4" PLYkNOOD. PV(4) .-5"X5"X3/S"P " LAG BOLTS tO BEAM - 'SIMPSON' LU 28 4. CENTIRE Z~~j SHEET BR06E SETION Tit? ScIe: 1 /2" Engineering Drov4irlg5 for: t. 3/05/01 The Renaissance Continuum The &rove Units R6vTsIon SA 14661 Mard Road, 5ulte 0 Oners Association v1 ftN WK WW 4=101 GPkd SFD PN. - -• -- Tustin, Calif. 412105 Hosp kMciij at El Camino Sheet Na. -156 TI4.4.O46 Real ______ Al 4 FAX '754.055-1 .Carlsbad, CA -. A20 A21 Ex BUILDINS P !A A ex OUILDIN& (4) MEN PIPE C40L : Titl?RIPE _SECTION ScIe: /1 1-01, Engineering rMIns for: iat.O/O/QI The Renaissance ContInuum The crove UrIt9 Gh4 1466 1 Myf ord 'Su Orer3 Association 4/20/01 PIN, Sheet No: - Tustin, Collf. c12105 He9p kMcj at El C.omlrio ReoI - -• 114.14.0466 - FAX 154.051 Corlsbod, CA Al 5 SLOPE TOP OF FTG AkNA5( FROM COL - :2% MIN FINISH SRADE *3 TIES #3 TIES @ S' O.C. MAX. SLOPED &RADE kMHERE OCCURS I /2" THK NON-SHRINK GROUT *5 VEST SEINF. '4. CONC. FT *3 TIES. STL. SUPPORT COLUMN VEST REINF. I - I ShCt Title BRIPE FOOTING 5r-ale: 3/4" = 1-0" Engineering Dron for: Dot. 03/0/0I The Renaissance Continuum -!. Revisions vevwoN 1 C4*4 5P I46I Myford Rood, Suite C. Oners Association - Sheet No. Tustin, Calif. C12,70a Ho5p kSay at El Camino Real I4.34.0466 Al 6 - FAX 154.0531 Carlsbad, CA 3/4" 5T1)CT I T46 PL'rk'4P V4ITH POd @ 6" OC., BOUNDARY lOd @ 6" 0.0., EDGES IOd @ 10" 0.0., FIELD OUNDR'( NAILING Y400P BRIDGE SEAM SIMPSON "000" COLUMN' CAP 4" x 4" x 3/16" TS STL SUPPORT COL 5Th SUPPORT COL 0" x 10" x 3/4" THK 5Th ANCHOR PLATE Y4ITH (4)- 5/4"(P x 12" ANCHOR 0LTS. 5Th SUPPORT COL . . site A ENTIRE SHEET ANIHOR FLAN Title Sheet 5R0E SUPPORT COL. Eiiglriecring DroIn9s for: nate 03/0/0I The Renolssonce Continuum -me. crove RzvlslonsUnitsReVISM ___ __________ 14661 M?ord Rood, Suite C Oners Assoclit1on - . Sheet No. TutIr,CoIIf. q2108 Hasp I&iLJ at El C.omlrio Rea l . " I4.34.0466 . . FAX 134.0531 : Carlsbad, CA Al 7F . ANCHOR PLATE - 5/4" STRUC.T I T* • PLYPO 5HTC7 KTH / IOd @ 6" O.C., / BOUNDARY /10d a 6" O.C., EDGES IOd@ 10 FIELD 1 /2" WX PLYV4P SHT& / I6d @ 16 B.N. (BOUNDARY NAILINCO M BEAM 2x FLOOR JOISTS kITH - SIMPSON "LPU" SERIES MTL HANcERS t 16" O.C. -, ? JST TO BM 5cole = Engincering Drov1ngs for: oat. OS/OSlO I The RonIssonce Continuum The rove Units ReVI&One OiNners Association GH4SPV 14661 Myord Rood, Suite C. Sheet No. 'Tustin, Calif. 4127705 Hosp oy ot E l Camino :Real- -714.754.0466 Al 8,. ' FAX 154.0551 C.rIbod, OA -. I /2" P.C. @ 42"; o.c,. xxS/S" PLATE VV (4) - S/S" xe" LA I.. SCREM :: T II"2 /2" I . @ 'f 5xx5/5" PLATE V/ (4) - /S" x6" LA ___ SCREfrM - uI - - - Sh ? HANDRAIL CCNNECTION Engineering DroIrg9 for: Revisions it. 05/05/01 The, Renaissance Continuum The d7rove Units - Oviners Association rLJtIn, Calif. 210 Sheet No. - • • • Hosp Noy ot El C.omirio Real - 114.154.0466 FAX 14.0551 Corlsbod, CA Al 9.. STONE FIN. @ STUCCO FINISH C7.1. FLA5HIN(5 SOFFIT SFERATION EX FLR FRM& EX MALL FRM S. * . ? BRIE AT VLALL Stole:Tit = Engineering Per: pat. O/O/Ql The Renaissance Gontlnuum The rove Units RavIsions _____ DrP(n /SP 146I MyPord Rood, Suite C. Oners Association .• Tustin C.oliP. q270S Hosp Noy ot El C.omirio Sheet No. Roo -714.754.0466 ______ FAX AX C.orlsbod, C.A I - - I - - •4 - 5 - - - ' -4. I -_ . I- - L :. •- • • -: ,I A -- - • = -- - .. - A C' ci (Jb ul - A 'S -? "S ',,S . ___ \ I Lo \' -' 111UtJJ n1 js m -0 U3 0 XO3 '?<u H ?i ç ni :lj II I I 2' rn rn >3; rti n 11 @1 ii I 1' S --S - -S. • S ALUM. EXPANSION JNT COVER - ANCHOR TO BRIDGE ONLY PEDESTRIAN TRENCH GRATE 8RIP6E FINISH 20 GA. G.I. TRENCH DRAIN - ALL JNTS SOLDERED frMATER. TIGHT STUCCO SOFFIT 4 DRAIN LINE TO DRAINAGE SYSTEM Sheet Title BRIDE DRAINA&E Sccile: I 1/2" = Engineering DroiIrs for: Revisions Data O/QOI The Renaissance Continuum The rove Units - • 14661 ?iord Oners Assoc.Iot1on • Shoot No. TustIr Calif. 412705 Hosp kNoy ot El Comma - Reol 1I4.14.0466 FAX 4.057 CorIsbOd, CA A22 & 2x RAFT ? RAFTERS AT The RenoIssnGe Continuum - 114.754.0466 SEAM Engineering DroIn3 for: The (rove Units Oners Association Ho5p kNy at El C.rnIrio Real Carlsbad, CA Pot. /OS/0l Revisions prMnSA GhkdSPD PH, Sheet No. - '. A2 3 Wo T46 ROOF SHT BOUNDR'( NAIL 2x SOLID BLK& Al (I) SIMPSON o35 EA BLK BLK& TO BEAM. x BE Sh I4I Myford Sod, Suite C. Tustiri,C.olif. 1710 FAX 154.0551 - - - .- -- - .-i - v't .5 I EX. NO 51W kMALL 8.N. SIMPSON f42 SEISMIC. TIE - RAFT TO EX. S1W MIN. Sx LEER V/ MIN (2) 5/8"0 LArv - - - BOLTS @ 2' O.C. LEER TO EX. 51W RAFT. Vil MTL HNR - RAFT TO . LEI7ER RAFT TO LEDGER !oi 1= The RnQIssonc,e Continuum 14661 MyPord Rood, Suite C - Tutin, CouP. 2108 - 5 .• . - FAX 74.0531 114.154.0466 A24' Engineering Drvngs for: The d7rove Units Oviners Association - Hasp Noy ot El C.omino Red CorI5bod, CA Pat. Q/Q/QI SFV Sheet No. f :v '. TILE ROOFING • OVER O* FELT • ROOF SHTG ROOF FING •• BIRD STOP CONT 26 GA. G.I. IVERTOR .• • • 5hee litr:t EAVE ScIe: • Engineering ProIr, for: pot. OS/O&'OI Th. R.enoissnG, Continuum The Grove Units • Revislons _________ Or— SA 14661 Myord Oners Association SFV Thstln, Collf. 2105 Hosp V9cj at El Camino Sheet No. rn4.134.0466 Real ______ A25 FAX 4.05i • Carlsbad, CA - SThP KALL FRAMING 5TUCCO OVER #15 FELT CONT. 2b6A C7.1. FLASHIN6 TILE ROOFIN6 OVM 50# FELT ROOF 5HT6 ROOF FRAMING Tit? ROOF 'c @ CONF I NED RIE SIe: 1 I/° 1-0" Engineering rv.1Irigs for: oto 0/0/0I The Renaissance Continuum. The Grove Units RøVISIOfl __ 14661 Myor P Oners Association Tustin, Callf. 5770a Hosp Noy at El Camino Rea - rn4.-74.046 I A26 FAX 734.0531 Carlsbad, CA I 1/2' = '-0' RvI&ore Pat. O/OS/OI n SA PN. Sheet A27. ' ... U U U .. .. -, - • •• SThP V4ALL FRAMING 5TV.,W OVER #15 FELT SCREW CONT. 266A 6.1. FLA5HIN(7 FELT ROOF 5HTC7 2x SOLID BLK6. - -- - ROOF FRAMIN& Sheet Title V17Y @ CONFINED RIPE - Engineering Droing for: The Renolssonce ContInvum The Grove Units I46I Myord Rood, Suite .C. Oners Association • Tustin 2105 Hop Noy ot El ComIno Roo 7I4.14.0466 FAX 4051 C.orlsbod, CA - 5-TILE ROOFING • OVER *O ROOFING * FELT :2x5 NAILER :2x2 NAILER RAKE TILE ) A 0 \ / DE&REESEVELE DC E SE DRIP ROOF FRAMIN& IXbTSOLI SHEATHING Sh 5-TILE ROOFIN& AT RAKE Tit? Sole: 1 1/2" = 1-0' Engincering Drap4ings for: Pat. 05/08!01 The Renaissance continuum 1.h& Grove Units Revisions 1 4661 Myord Rd, Suite C Ov4ner5 AssoIot1on Tustin, Calif. q2108 Ho5p kNay at El Camino - SheetNo. -, •- .• Reol 1I4.154.046 A2 8 * FAX 7540551 Carlsbad, CA - 4:7. - •IJ • : V • ADDITIONAL WNT 2xLK STUCCO OVER #15 FELT C.ONT G.I. kMEEF SCREE ONTI 'Z FLASHING COt4T 6.l. FLASH I • / PECK I N - LD PECK SHTG -'I V - V - V' V •V * FLASHING Sc Title Engineering Drar4ings for: V 05/08/01 : SA The Renaissance Cont1rvum e cvroye units Revisions 0v4n6r9 Association ChW I4I Myord Rood, Suite C TustIr; olIf:.42io Hosp Nay at El Camino Sheet No. V V rn4.154.046 Real • A29 FAX 154.0551 •' Carlsbad, CA 'BRIDGE REPAIR To I c' 2362- HOSP WAY CARLSBAD, CALIF. SHEETINDEX V ' Al COVER SHEET. V A15c SECTION - LONGITUDINAL V At SCOPE OF WORK A16 DETAIL - BRIDGE FOOTING V A3 SECTION 01000 - GENERAL NOTES A17 'DETAIL - BRIDGE SUPPORT COL A4 SECTION 01000 - GENERAL NOTES A18 DETAIL - BRIDGE JST TO BM A5 SECTION 01000 - GENERAL NOTES A19 DETAIL - HANDRAIL ANCHOR V *6 SECTION 06100 - FRAMING NOTES *20 DETAIL - BRIDGE TO WALL V A7 ' SECTION 06100- FRAMING NOTES A21 DETAIL - BRIDGE @ THRESHOLD V AS SECTION 06100- FRAMING NOTES *22 DETAIL - BRIDGE DRAINAGE A9 SECTION 06100 - FRAMING NOTES *23 DETAIL - RAFT TO BM AID 'SECTION 07600 - FLASHING NOTES *24 DETAIL - RAFT TO LEDGER V All SITE PLAN *25 DETAIL - EAVE V V Al2a BRIDGE PLAN *26 DETAIL - CONFINED RIDGE Al2b BRIDGE PLAN ' *27 DETAIL - WOW @ CONFINED RIDGE A13 FOUNDATION PLAN V *28 DETAIL - ROOFING AT RAKE .• *14 -SECTION - LATERAL *29 DETAIL - DECK FLASHING V V Al 5a SECTION - LONGITUDINAL ' A30 DETAIL - GUARD RAIL Al 5b SECTION - LONGITUDINAL *31 DETAIL - GUARD RAIL V A32 REPAIR SCOPE OF WORK Dm 9IT Sheet ,1 t -r-- V Title ' T 5-ale: NONE V The RnoIssince ContInuum The Grove Units orm SPO V 14661 Mgford Rood, evit-ce C, in Overs Association IGG -- Sheet No. Tustin, C.Iif. q2-1O ' V V Hasp y at El Camino 1I V I I? I Ar.L/A# # P 11A. . Seol V V V FAX 734.0537 ' V Carlsbad, CA V : •' V C.6oi ow-,,I mal OWN I. REMOVE ROOF ELEMENT. V 2. DISCONNECT ELECTRICAL LI&HT V • V AND CONDUIT. V 3.1 CAREFULLY REMOVE TOP REAILIN V SYSTEM MILL BE REINSTALLED) 4.. DEMOLISH EX15TIN6 DECK SYSTEM. 5.• INSPECT EXISTING SEAM TO FOUNDATION V T CONNECTION AT PARKINc' LOT. CONTACT V ARCHITECT Y4ITI-4 INFORMATION. V INSPECT EXISTIN6 FRAf-IIN& FOR DRY ROT AND/OR TERMITE PAMAE (INCLUPIN V. SUILDINc kALL). V CONSTRUCT NEY4 DECK FRAMIN&. V 5.V REBUILD EXISTING ROOF ELEMENT AND RAILIN . V V q INSTALL DRAINA6E V .'10. V APPLY "LIFE PECK' COATING SYSTEM PER MANUFACTURERS SPECIFICATIONS. V V II. APPLY BUILDING' PAPER, AND LATH V V PLASTER (COLOR SHALL MATCH EXISTING) V V (PROTECT DECK C.OATIN') V .- 12:. RE-CONNECT LI6HT FIXTURES. V I; CLEAN-UP AND REMOVE ALL DEBRIS. Sheet. ,0 1 iAI1 Scale: Title V. V Engine.-ring Dror.Ifrg9 for: V 03/0/0I The Renoissoflce COfltiflUUtfl The Grove Units RevI,Ion SA • 14S61 Myford Rood, Suite C Oners Association V V V Sheet No. Tustin Calif. q270 V . IAL.,i i ,if1=1 -714.774.04e6 . • FAX 734.0537 _• , liii Real Carlsbad, CA A2. SECTION 01000 - &ENERAL I. ALL V40RK SHALL COMPLY V'UTH APPLICABLE STATE, COUNTY, AND CITY ORDINANCES AND THE IC(1 UNIFORM BUILDING' CODE, l°(1 UNIFORM BUILDING' CODE STANDARDS, l7 UNIFORM MECHANICAL COPE, IT UNIFORM PLUMBING' CODE, AND THE lclqb NATIONAL ELECTRICAL CODE. 2. THE G'ENERAL BUILDING' PERMIT.AND PLAN CHECK SHALL BE PAID FOR AND OBTAINED BY THE CONTRACTOR. ALL OTHER PERMITS SHALL BE PAID FOR AND OBTAINED BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE FOR THEIR PORTION OF THE VOW. . NO SUBSTITUTIONS YHLL BE MADE VITHOUT THE OV4NERS PRIOR MITTEN APPROVAL. 4. THE OVNER MAY ORDER EXTRA V4ORK OR MAKE CHANGES BYALTERING', ADDING' TO, OR DEDUCTING' FROM THE V4ORK. THE CONTRACT SUM BEING ADJUSTED ACCORDIN&LY. 5: THE INTENTION OF THESE PROJECT DOCUMENTS IS TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, AND TRANSPORTATION NECESSARY FOR COMPLETE AND . PROPER EXECUTION OF THE V4ORK. . THE ARCHITECT DOES NOT V4ARRANT NOR GUARANTEE, EITHER EXPRESSED OR IMPLIED, ANY PRODUCT THAT HAS BEEN MENTIONED OR IDENTIFIED BY THEIR TRADE NAME IN THESE PRCCT DOCUMENTS. 1- ALL TRADES SHALL FURNISH ALL LABOR, EQUIPMENT, MATREIALS, AND PERFORM ALL VORK NECESSARY, INDICATED, REASONBLY INFERRED, OR REQUIRED BY ANY BUILDING' AND/OS SAFETY CODE YLTH JURISDICTION TO COMPLETE THEIR SCOPE OF I10RK FOR A COMPLETE AND PROPERLY FINISHED JOB. . &ENERAL NOTES Engine Scale: The RanoIssanceC4ntInuum I466IMyford Road, Suite . Tustin, Calif. 412i0 - 714.734.0466 FAX 134.0531 e9Dra e, &rove Units Oners Association Hasp V4ay at El Comma Real Carlsbad, CA VCA0 05/05/01 mm 5A/5M SPP Sheet No. A3 ______ . . . .4. SECTION 01000 - GENERAL CONT. '. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUt LPI HG LINES AND LEVELS. THE CONTRACTOR SHALL COMPARE CAREFULLY THE LINES AND LEVELS SHOVIN ON THE PROJECT DOCUMENTS VIITH EXISTING LEVELS FOR THE LOCATION AND CONSTRUCTION OF THE VLORK. ANY DISCREPANCIES IN THE PROJECT DOCUMENTS, DISCREPANCIES BETV4EEN EXISTING STRUCTURES AND PROPOSED V4ORK, OR DISCREPANCIES BETV4EEN PROJECT DOCUMENTS AND EXISTING STRUCTURES / SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCING YUTH ANY V4ORK. q. ALL TRADES SHALL DO THEIR 010*4 CUTTING, Fl TTIN, PATCHING, ETC., TO MAKE THE SEVERAL PARTS OF THEIR - . Y40RK AND.OTHER TRADES' V4ORK TO PROPERLY FIT TOGETHER. .. b. ALL TRADES I'MILL, AT ALL TIMES, KEEP THE PROJECT AND THE PROJECT SITE FREE FROM THE ACCUMULATION OF V4ASTE MATERIALS AND RUBBISH CAUSED BY THEIR V4ORK. . AT THE COMPLETION OF THE PROJECT REMOVE ALL RUBBISH, TOOLS, SCAFFOLDING, AND SURPLUS MATERIALS .. AND LEAVE THE JOB IN A BROOM CLEAN CONDITION. II.. BEFORE SUBMITTING A BID, BIDDERS SHOULD CAREFULLY . EXAMINE THE PROJECT DOCUMENTS, VISIT THE SITE OF THE YSIORK AND FULLY INFORM THEMSELVES AS TO ALL • EXISTING.CONDITIONS AND LIMITATIONS. .4 -• -. Title GENERAL NOTES GONT Engineering Drosllng9 for: The Renalssoflce. COfltIflUUfl1 The &rove Units 14661 Myford Rood, Suite C OiNners Association TList1n,cii#. c1270a Hasp V4oy at El Comma Real rn4.4.0466 ., FAX -754.055-1, . Carlsbad, CA OWAD Q/Q/Qi RevI5Ion5 ___ 5A/5P cI*dspp . Sheet No. __ Al SECTION 01000 - &ENERAL CONT. 2. THE PROJECT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. UNLESS OThERV4I5E 5H0VIN, THEY DO NOT INDICATE THE METHOD OF CONSTRLJC.TION. THE CONTRACTOR VIILL SUPERVISE AND DIRECT THE Y4ORK AND HE }'MILL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS METHODS TECHNIOUES, SE&IJENCES, AND PROCEDURES. OBSERVATION VISITS OF THE V4ORK BY THE ARCHITECT V4ILL NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES REOUIRED FOR THE Y4ORK, 10*4ICH IS THE RESPONSIBILITY OF THE CONTRACTOR.. ANY SUPPORT SERVICES PERFORMED BY. THE ARCHITECT kMILL BE DISTIN&UISHEP FROM CONTINUOUS AND DETAILED . INSPECTION SERVICES V4HICH ARE FURNISHED BY OTHERS THESE SUPPORT SERVICES PERFORMED BY THE ARCHITECT, Y4HETHER OF MATERIAL OR V4ORK, AND V4HETHER PERFORMED PRIOR TO, vLlRINCv OR AFTER COMPLETION OF * CONSTRUCTION ARE PERFORMED SOLELY FOR THE .PURPOSE OF ASSISTIN& IN OUALITY CONTROL AND IN ACHIEVING CONFORMANCE V4ITH THE PROJECT DOCUMENTS, BUT THEY Po NOT &UARANTEE THE CONTRACTORS PERFORMANCE AND JMILL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. i. ALL OMISSIONS OR CONFLICTS BEW4EEN THE VARIOUS ELEMENTS OF THE PROJECT DOCUMENTS V4ILL BE BROUSHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEPINS Y4ITH ANY V40RK SO INVOLVED. GENERAL NOTES CONT . Engineering DrQr4hg9 for: . VaLo 03/0/0I The ReflOiSSflC Cg'OfltIfltJUfl The Grove Units _____orm 5Af510r, Chkd I46I v;, .4 goad; Suite C. OVli1erS Association Tustin, Calif. q2-70 ••. fl4.1.34.O466 -. FAX 734.051 Hosp Viay at El Comma ReI Carlsbad, CA A5 SECTION 06100 - FRAMING I. JOISTS SHALL BE SUPPORTED LATERALLY AT THE ENDS ANP AT EACH SUPPORT BY SOLID BLOCKING EXCEPT '.}'NHERE THE ENDS OF JOISTS ARE NAILED TO A HEADER, BAND OR RIM JOIST OR TO AN ADJOININ& ShiP OR kMITh APPROVED METAL HANGERS. SOLID BLOCKING SHALL BE NOT LESS THAN A NOMINAL 2 INCHES IN THICKNESS AND THE FULL DEPTH OF THE JOIST. NOTCHES ON THE ENDS OF JOISTS SHALL NOT EXCEED ONE FORTH THE JOIST DEPTH. HOLES BORED IN JOISTS SHALL NOT BE V4ITHIN 2 INCHES OF THE TOP OR BOTTOM OF THE JOIST, AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED ONE THIRD THE DEPTH OF THE JOIST. NOTCHES IN THE TOP OR BOTTOM OF JOISTS SHALL NOT EXCEED ONE SIXTH THE DEPTH AND SHALL NOT BE LOCATED IN THE MIDDLE THIRD OF THE SPAN JOISTS FRAMING INTO THE SIDE OF A VOOD 6IRDER OR BEAM SHALL BE SUPPORThD BY I .CB.O. ArxOVEP METAL HANGERS. S EACH SHEET OF PLYV900D SHALL CONTAIN A MINIMUM OF EIC3HT SQUARE FEET AND SHALL EXTEND OVER THREE BEARING LINES Y4ITH FACE GRAIN PERPENDICULAR TO JOISTS. 5. PROVIDE AND INSTALL EDGE NAILING OVER ALL SHEAR, • BEARING,.AND EXTERIOR V4ALLS. ALSO FLOOR BEAMS, STRUTS, AND AROUND ALL OPENINGS. 6. FLYVLOOP USED FOR FLOOR OR ROOF SHEATHING SHALL BE BONDED BY EXTERIOR GLUE. PLYV4000 ROOF SHEATHING EXPOSED ON THE UNDER SIDE SHALL BE APPROVED FOR EXPOSED EXTERIOR CONDITIONS. (ALTERNATE TO PLThOOD: I.CB.O. ACCEPTED ORIENTED STRAND BOARD) S Title - heet FRAMING NOTES Engineering Drmhigs for: D. 03/0/01 The RenoIssonGe Continuum The &rove Units ____ SA/SPP 14661 Myford good, Suite 0 Oners Association - S • Sheet No. Tustin, Call?. 412-106 Hop Y4ay at El Camino Reol S 714.734.046 A6 -. FAX 734.071 Carlsbad, CA -I FLOOR SHEATHING - 5/8' COX T46 PLYV400D (P.S.R. 32/1(b) V41Th lOd AT 6 INCHES 0.C., BOUNDARY NAILING ON) lOd AT 6 INCHES O.C.., EDGE NAILING (EN) lOd AT 10 INCHES O.C.., FIELD NAILING ALL EDGES BLOCKED (ALT: TONAE-ANDGROOVE JOINTS) GLUE AND NAIL PLYV4000 FLOOR SHEATHING TO ALL POINTS OF BEARING. 0. THE BUILDING DEPARTMENT SHALL BE NOTIFIED FOR INSPECTION OF ALL FLOOR AND ROOF DIAPHRAGM NAILING, SHEAR V4ALL NAILING, AND ALL SHEAR CONNECTIONS PRIOR TO CONCEALING NAILING. FIRESTOFFING SHALL BE ROVIPED IN THE FOLLOV4ING LOCATIONS: 20.1 IN CONCEALED SPACES OF STUD ALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 0-FOOT INTERVALS ALONG THE LENGTH OF THE V4ALL. 202 AT ALL INTERCONNECTIONS BETkMEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILING. ? FRAMIN(5 NOTES CONT Engineering Drainge for: D. 03/0/01 The Renoissonce Continuum The &rove Units _____ 5A/SPP Ghkd5PP 14661 MPord Pd, SvIte 0 Oners Association - Sheet No. 'Tustin, Calif. 412,705 Hasp Ilay at El Comma - * Real '•' 714.734.0466 A7 . FAX 734.031 Carlsbad, CA. 4 • SECTION 06100 - - FRAMIN& CONT 203 IN CONCEALED SPACES BETV4EEN.5TAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND 5ETV*4EEN STUDS ALONG, AND IN LINE V4ITh THE'RUN OF STAIRS IF THE V4ALL5 UNDER THE STAIRS ARE UNFINISHED. 20.4 IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS 'MHICH AFFORD A PASSAGE FOR FIRE AT CEILING -. AND FLOOR LEVELS, V4ITH NONCOMBUSTIBLE MATERIALS. II. FIRESTOPPINcS SHALL CONSIST OF NOMINAL 2 INCH LUMBER, EXCEPT FOR OPENINGS AROUND VENTS, PIPES, DUCTS, ' CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS kNHICH '4 'AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS V4HICH: SHALL USE MINERAL V400L. I2• NOTCHING OF BEAMS IS NOT PERMITTED UNDER ANY C I RCUMSTANGES 15. A 'HOLE NOT GREATER IN DIAMETER THAN 40 PERCENT OF ,' THE 51W kMIDTH MAY BE BORED IN ANY V400D STUD. BORED HOLES NOT GREATER THAN 60 PERCENT OF THE MIDTH OF THE STUD ARE PERMITTED IN NONBEARING PARTITIONS OR IN ANY kMALL Y4HERE EACH BORED STUD IS DOUBLED, PROVIDED NOT MORE THAN TO SUCH SUCCESSIVE DOUBLED STUDS ARE BORED. IN NO CASE SHALL THE EDGE OF THE BORED HOLE BE NEARER THAN 5/6 INCH TO THE EDGE OF THE STUD. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF :. STUD AS A CUT OR NOTCH. Sheet FRAMING NOTES WNT . Title Engineering Drawings for: Date 03/05/0I The Renaissance Cofltlnuum The Grove Units arm SAJ5Pt7 _____ I466I Myford Road, Suite C, OnerE Association Sheet Na. 'Tustin, CoIiP. q2-10e Hasp kA4oy at El Comma - Reol I4L134.O466 ______ A8 FAX 734.051:. Carlsbad, CA 4 '_'•l•' I.. .• • - - :•_ SECTION 06100 - FRAMING CONT. 14. SOLID SAN RECTANGULAR LUMBER BEAMS, RAFTERS, AND JOISTS SHALL BE SUPPORTED LATERALLY TO PREVENT ROTATION OR LATERAL DISPLACEMENT IN ACCORDANCE 11TH THE FOLLOPMING: IF THE RATIO OF DEPTH TO THICKNESS, BASED ON NOMINAL DIMENSIONS, IS: 2 TO I, NO LATERAL SUPPORT IS REQUIRED. 3 TO I OR 4 TO I, THE ENDS SHALL BE HELD IN POSITION, AS BY FULL DEPTH SOLID BLOCKING, BRIDGING, NAILING OR BOLTING TO OTHER FRAMING MEMBERS, APPROVED METAL HANGERS OR OTHER 1 ACCEPTABLE MEANS. '' c.: 5 TO I; ONE EDGE SHALL BE HELD IN LINE FOR ITS 'ENTIRE LENGTH. I, BRIDGING, FULL DEPTH SOLID BLOCKING OR CROSS BRACING SHALL BE INSTALLED AT INTERVALS NOT EXCEEDING 8 FEET UNLESS BOTH EDGES ARE HELP IN LINE. E. 1 TO I, BOTH EDGES SHALL BE HELP IN LINE FOR THEIR ENTIRE LENGTH. ROOF TRUSSES SHALL BE SUPPORTED LATERALLY AT POINTS OF BEARING BY SOLID BLOCKING TO PREVENT RO~TA ION~ANV LATMERAL 01S~PLACEIME~NT. SPECIAL INSPECTION ITEM' * REQUIRED .. REMARKS STRUC. CONC. - 2,500 psi YES FRAMING NOTES GONT Title t o3/oe/oI pmvmmq CAW I4bbI Myford Road 5J Oviners Association , Tustin, C.alif. q2-7O * Sheet No. Hasp YSIay at El Camino A9' FAX -754.056-7 Corlsbod, CA SECTION 01600 FLAS1-UNC I. ALL FLASHING SHALL BE 26 &AUE, &ALVANIZED IRON SHEET METAL. ALL ROOF PENETRATIONS SHALL BE PROPERLY FLASHED AND/OR COUNTERFLASHEP TO PREVENT YtATERFROM PENETRATIN& TO THE INTERIOR OF THE STRUCTURE. - S. :FLASH ALL EXTERIOR OPENIN&S AND ROOF TO HALL JOINTS. 4. VERTICAL EXTERIOR OPENINGS (DOORS, k4INDOV4S, ETC) SHALL BE FLASHED BOTTOM, SIDES, AND TOP Y4ITH VLATERPROOF (RAFT PAPER. EACH BOTTOM, SIDES, AND TOP KRAFT PAPER FLASHING' SHALL BE A CONTINUOUS, • FULL LEN&T14 PIECE.. 5. POOR OPENINS SHALL HAVE AN ADDITIONAL METAL FLASHINS V4ITh DRIP ABOVE. Sheet FLASHING NOTES Scale; Engirkeering Drcmhgs for: 05/05/01 .0w" 'The R&flOI5StflC The &roVe units cwm Gd SFP I4661 MyfordRoad, Suite C Ov4ner5 Associotion . Tustin, C.alif. q2-7O Ho5p I'Moy at El Camino Sheet No.: I4.4.046 Real Al 0 FAX 134O51 Carlsbad, CA SHEET 2 ENI 4 jNOT A PART I 2362 I SITE FLAN SGOIC: NONE The anoIssance Engineering t)rovifrtgs for: o 05/0001/005/0001/01 The c9rove Units 1. 466 1. Myford Road, evite 0. . Oviners Association 5heet No. Tustin, Calif. C12105 Ho5p v4oy at El Camino Real 714.734.0466 All FAX Car lsd, CA I.. -• * - - •' OF ROOF ABOVE , /•, i 51-41 1/21, SI - REPLACE EXIST. 4x6, EXTEND TO EX.kE GLB USE INVERTED PC.46 VARIES - EXIST. STEP 7. ASOCGUR / - EXIST. SIDEP4ALK - 4 )1tRE OCCURS 71 . EXISTING SLOPE 2% MIN. - FIELD VERIFY () RETAINING AI4 LL HERE - OCZURS 1) 4AIF SI - -. (=7) Title Shect SR I 17GE PLAN Scale: The Renoissor,ce Continuum EgDangsfor Revistom . 0'7/26/01 14661 Mf'ord Road, Suite C Oviners Association Tustin, Calif. q2-10E Sheet No. . Hasp Hay at El Camino Real - V 114.734.0466 ______ Al2a FAX 1-14D551 CorIsbd, CA V p $ 1: REPLACE EXIST 4x&, I A —5c>------ ,- NY 'IX b POST I.YV PC I ,- —REMOVE i STORE EXIST. 4xS BM I I (W GONG. TILE ROOF, REPLACE o 0 I I EWE' PAPER P*? I I CONSTRJXTIOW l• ___ • •\ I] GOMPLE1t/. •.: ______ ____ 7. -EX. 2xb LEI76,ER / TO REMAIN N EX. (4) 7===\ To REMAIN EXI SLOPE fLA5HING - \ - _________i • 511UCT. 'I - SRI 17&E • S SELOV4 5'-1/2" —(E)RO0F Sheet BRIDE PLAN 0 Scale:Title Engineering VQYfl95 for: Dicta Thö RenoIssonce Cofltlnuvm The &rove Units Rav19 K.E'. _________ 146b1 Hyord Road, Suite C. Ov.iners Association Sheet No. Tustin, CaIW. 412108 Hosp1oy at El Camino 714.734.0466 Al 2b FAX 134.051 Carlsbad, CA - ." ? FOUNPATION PLAN Engineering Drorikgs for: The &nOISSnCI COflt1fltMfl The &rove Units 14661 Myford Road, SvIte C, Ovners Association Tustin, CIif. q2-108 Hasp Noy ot El Camino Real 1l4.4.046 FAX 134.0531 Gorlsbod, GA PTO Ravlsions 03/08/01 SPD/SA spy- _________ Sheet No. All VARIES ('-q" TO ?'O") " r .\ SQ. K1. RAIL \' PIC,KETS -. I \0 P4.1. POST 0 - 6-0' O.C. MAX - I 3 c i ''— f 1/20 ro (EA. SIDW STLIC0001 Tyr. REMOVE EXISflN& V PER STRLJCT. in I \ VIA. POST, TYP. EXIST. 2x& STUDS-0 24' 0 C PELE EPDXY TYP, REPLACE AS PE)ED \ 'J _ EXIST. [ PLYVIOOI7 II SYSTEM BY 'LIFE DECK' OR EQUAL REPLACE AS NEEDED V — 5'x5'xl'P P41(4) 1' "' BOLTS V _V_VVV_VVVV V V BEAM PER STRUCT. - V '-2x FRAMIN& PER STRUCT. 4 V V V RE SHEET 5RI0E SECTION Scole: 1/2" = I'-O" Dot. 0'7/26/01 The Rencissance Continuum The Units 14661 Myford Rood, Suite C Oviners Association V rr V Tustin,C.olif. q27O Sheet No. V Hasp Noy at El Comma V Real V V 1I4.734.O466 V FAX 34.0 V Corlsba d, CA A14 - .. FHI PR0G9 T0TAI SPARGAilTtLEv P41P9PN4 SEAM DE DIM D1 DIM V2'SUE I1'UEP 2330 13-IO' 3-6' 6'-II' 6x10 4-0' 3-0' 19 4x4x5/t6 IWAAVEP 2332 14-0' 3-6' T-O' 6,d0 4-0' 5-0' 19 4x4x9/16 tNCUfP 2934 4-0' 3-6' -r-o' 6,d0 4-0' 3-0' 15 4x429/I6 IWAIAND 2336 I4'-2' 9-6' T-0' 6*10 4-0' 5-0' 19 449/16 IPuW 2940 11-4' 2'-lO' 5-b' 6*10 4-0' 3-0' 19 4x4,Sfl6 !WAAVM 2942 5-0' 3-3' 6-6' 6*10 4-0' 3-0' 15 4*4*9116 IWAAVW 2944 14-b' 9-0' 1-4' 6*10 4-0' 3-0' 19 4*4*9/16 NOT A PART 2350 Ib-4' 4'-?' q-2' 6*10 4-0' 5-0' 1944*9/16 ItAUAXMP - 2952 0-3' 4-1' '-2' 6,40 4-0' 3-0' 1'S 4*4*9/l6 PC 2360 fl'-R 4-5' 5-10' 6*10 4-0' 0-0' 194*4*3/16 LMXX SWORATE F00T 1 2962 22-4' 5'-l' Il'-2' 6*10 4-0' 3-0' 19 4*4*9/16 INCUEP 2360 25-6' 61-0' 6-6' 5 11512 4-5' 91-8 19 55*3/l6 Wr A PART 2502 25-5 6-0' I4'-2' S 119*12 4-8' 9-8' 15 5*5*9/16 Title BIGE SECTION scale: /" = 11-013 Engineering Profrgs for: ocas 03/0e/0I -. . The 'rove Units .:,14661 Myford good, Suite Ov4ner Assoc.ition C#" SF17 5hoot MU Tustin, c.I1f. c12-105 - G06/26/01 L(Tt NO. Hop V4oy at El Camino Seol rn4.7134.046 Al 5a F _____ FAX 734.O51 Carlsbad,C.A - NEV4 4xb POST PAINT, COLOR PER ARCH. FIELD CUT PRECAST CAP TO FIT POST P.C. CONC. CAP LITE STONE "APC I4PG rr EG I / I 11 NEkM'M.I. '1 P !x:STEPS RAILIN&\ AS OCCUR ::. IHififfiffi fflfflfflj __ \Ej - NEV4JEX. &LB 4Er4/EX FT&S. / PER STRL)CT. / 1 NQTL: I. PROVIDE BID ALT. FOR LJ RECESSED LIGHT FIXTURE AT EACH - -• - SThO BOLLARD • 2. THIS DETAIL APPLIES TO ALL -. - BSID&ES FROM 2' TO O' IN LENGTH mmom OHM (BLDS :2560,256:2) Shoat, ELEVATION 1e:Tit Engineering Droing for*: D. 07/26/0I The Renöissone Gontinuum The Grove Units Rv1ens 14661 Myferd Road Suite C 0v4flers Association • - Sheet No. :Tustin" Colif. 412705 ot El Comino - -; Real • 7I4.1.4.0466 Al 5b . . FAX T34.0531 GrIsbd, CA - -- -. •'•-. NEV4 4x6 POST PAINT, COLOR PER ARCH. = FIELD CUT PRECAST CAP TO FIT POST P.C. CONC-.- CAP LITE STONE "APC I4PC." 'rrp 12 EX. ___1/2" op A" MAX AS OCCUR a L CU '.4 A 30 NEX &L Jj E. STING BLDG. :'.': OPEN 1• ____ r r NEI.N/EXFT&S. /LT PER STRUCT. ' NOTE: I. PROVIDE BID ALT. FOR RECESSED LIGHT FIXTURE AT EACH * STUCCO BOLLARD • fl . 2. THIS DETAIL APPLIES TO ALL BRID&ES FROM IT-b" TO 20' IN LEN&TH •. (BLDS 256Q, 23(02, 2550, 2552) Shoat Title SRI&E ELEVATION 1C: Engineering Drordirlgs for: got. 01/26/0I Thek Ranoissone CntInuum me 'rove Units • orm K.&. II1I 14661 Myford Rood, Suite C OkNners Association * Sheet No. Tustin, CouP. 412106 Hoop 104ci at El Camino Pool *t• Al ;•• rn4.04.0466 • C -TAX 154.0551 Carlsbad, CA EX. STEPS ---\--- NEI'4kN.I. 1• '1/ 1RAILIN I ii I CONC. FT -' #5 TIES 5Th SUPPORT, COLUMN N 2IIIiI VEST REINF FLN STL SUPPORT COL :. - >— SLOPE TOP OF FT -. . - -' AV4A FROM COL - 2% MI N• ' GRADE .....L—FINlsH (3) *3 TIES IN.I *3 TIES @ " O.C. .. 14, MAX. - --- -•-------J--- -----SLOPED GRAVE - V4HES! OCCURS • I— - __i I I 1/2 " I THK ,.;' z 0 - NON-SHRINK GROUT (4) *3 VEST REI NF. "CLR AENTIRE SHEET SEC. sheet BRIDGE FOOTING Scale: 3/4" Title • • Engineering DrorIIng for: D. 03/06l0 I The Reno1ssone Continuum me 6ve RtvtIons orm SPD. P"Ui r 1.ill-I m'I tt 5 I4146W Myford Rood, Suite C. - Tustin, Calif. 412106 • - ,,,', Hasp V4o at El Camino Sheet No. -- - - Real • 114.734.0466 -Al 6' .: FAX 134.O31 Carlsbad, CA /4" STJ)C.T I 16 G PLYVIPVITh IOd BOUNDARY IOdo 6" O.C.., EDGES IOd 10" 0.., FIELD BOUNDRY NAILING Y400D BRIDGE BEAM SIMPSON "C.CO" COLUMN 15 STL SUPPORT C.OL PER TABLE STL SUPPORT C.OL 10" x 10" x 5/4" ThK STL ANCHOR PLATE VIITH (4) x 12" ANCHOR BOLTS ANCHOR PLATE IH STL SUPPORT COL 5IJ5I 70/ A ENTI RE SHEET ANCHOR PLAN Title Shut SRII7&E SUPPORT COL. Engineering DrovIn for: D. 05/0/ 'The¼anoieeone Continuum me rove units vt*Ions __ SFV I46bi !'4yPàrd Road, Suite C Oviners Assotion WIN" ft Sheet No. I. S - 4••foomr Tustin, Calif. Hasp Y'4y at El C.mIno Real 114.154.0466 Al 7 FAX 134.0551 Carlsbad, CA • 1 • - /4" STRUCT I T* - I LYV4P !*4T' Y41Th / IOd 0 6" O.C.., I BOUNDARY -. / IOd o 6" O.c.., !DE / - - IOd 0 10" 0.G., FIELD / 1/2" COX PL.Y4D SHT6 I 2x SILL, I"4ITN I6d a 16" I / O.., MAX - B N (BOUNDARY I NAILINC i^V BEAM 2x8i FLOOR JOISTS ITH -, 5IMPWN "LPU" SERIES • - MTh HANGERS e 16" 0.C.. Shut SRII7E JST TO SM • ° = Title Engineering Dro4Ing for: Dat. 03/08/01 The Renaissance Gontlnuum The Grove units 0v4nere Association 14661 MyfordRod, SuIte C • Sheet -No. Tustin, c.IW. 412106 Hosp ftq at El Camino RI 714.734.0466 FAX 734.0337 CrIb, CA - .1.1 2"P@42" 5x5x3/" PLAT! Y41 x6° LA& -'HANDRAIL CONNECTION "11-011 Erineering Drovifr for: Dot. 03/05/0I The Renaissance continuum The &r-ove Vrits ormn SA GNd .14661 M4for.d Road, evite C. SPp Onere Association 5hvet No.. Tustin, C.ollf. 412106 ap fty at El Camino Reol rn4.134.0466 Al 9 FAX i34.051 Oarlal=d, CA STONE FIN. @ PLY VC SHT • STUCCOFINISF4 C7.1. FLA5HINC7 SOFFIT I" 5EPERATION EX Y4ALL FSMc fi• sheetSR&E AT VALL Scale: 111 11-011 Title EnGIneerIng DroiIngs for: MAO 03/06/0I Tha R.M0195ance Continuum The Grove t)nits OINrsrs Association I466IMy?ord good, SIte C, IONS Tustin, Calif. q21708 Hosp v t El C.omlno Shoat No. • Real - rn4.-734.0466 A20: FAX 40537 Carlsbad, CA - * _•_•'* *** -I 5RIO&E FINISH - PLY PO OR THRESHOLD EX.FLR& = C7.1. FLASHIN& - SIP! FRMC7 * - -a- SRIJ7E AT THRESHOLD - Engireerin Droriing for: The RenoIseonGe Continuum The r-ove ur,Its I466I Myford Road, evite C. Ok4 Association TutIn, C.ollf "12106 Hasp v4oy at !I Camino Reo - 114.734.0466 FAX 734.051: - Carlsbad, CA *. .4 - *- C. - - I '' = it-oil onto 03/OSlO I Røvtstons Drvm SA/51"'D GI*d SPP - PH, Sh..tNo. A2.1 V••VV i 4 • V V ALUM. EXPANSION JNT COVER- - ANCHOR TO BRIOC ONLY PEPESTAN TRENCH - .I. TT1 / / I I / •• FLASH'S 1 BP 9E FRAMING EXTEND l/4 MIN V BELOYNI SOFFIT $N LR SCO SOFFIT • EX.CONC.. V V HEAPV(ALL TO REMAIN ENTIRE :: V SHEET BRIDGE DRAINAGE V Scale: Engineering Drav4" for: 01 The ssonce conunuum Cvrove Ravons : = aff em 0*4 SFP 14661 VMford Rood, Suite C Owners Association V Tustin, Calif. q210e Sheet No. V Ho5p Hay at El Camino V Real V -71-4.-r-34.0466 FAX734.O51 Carlsbad, CA A.22 Ix T46 ROOF SHT67 BOUNDSY NAIL 2x SOLID BLKY4/ (I) SIMPSON o35 EA • BLK BLK6 TO BEAM 2x RAFT 4x BEAM 4 Shut Title RAFTERS Al SEAM le: Engineering The¼ RnoIssnGe continuum Dr1n R m've vleions 0&'Ol SA SPO 14661 t4yPord Rood, SuIteC Ok'4ne r"e A9GOC.iotion Tustin, Calif. 412108 •. 5heet No. - - • Hasp Nay at El Camino - - - 1I4.14.0466 A23 - •. FAX 734.051 Gorlsod; CA • -. EX. YV STUD Y(ALL B.N. SIMPSON H2 SEISMIC. TIE - RAFT TO EX. STUD MIN. Sx LEP&ER V'4/ HIM (2) S/" LA6 BOLTS @ 2" O.C. LEDGER TO EX. STUD ;. RAFT VV MTL HNR RAFT TO LEPER I . 1'• - C - Sheet Title RAFT TO LEDGER 11 '-0' Er Igimearing DroriIng for: got. o/o/ol The Renaissance. C.ontlnuum The Grove Units RavIIons SPP/5A ii 1iyor Oners Association TutIn, C.ollf. q2-70s Hasp Hay ot El C.omlno Reol rn4.754.0466 A24 FAX 134.0531 Carlsbad, CA - . •V.4 V V TILE.ROOFINC7 V OVER 50# FELT V V V ROOFSHTG V ROOF FRAMING - • V V V BIRD STOP . V V • CONT 26 67A. .I. ' V V V PIVERTOR - V IV • V • V Sheet EAVE 11/2" = '-a' Title, V EngIneerIng Drotrg for: Date osios/oi Tho Renclissonce Continuum The Grove Unite Rcvlon Prp, SA 14661 Myord Road Suite C. Ok4ner's Association V Shoat No. - Tustin, Calif. 412106 •Hosp Noy at El C.rnir ______ •V VVV V Real VVV• V . V1f4 O4 _____ V A25' FAX 14.0551 V Carlsbad, CA • V V V. -. V • - 4 V 1tV V4ALL FRAMIN6 2x SOLID BLKrz,. 5MXZO OVER #15 FELT CONT. 26 C SCREED CONT. 2bGA 6.1. FLASHIN6 SOLID 6ROUT - - -----. .- ROOF FRAMIN6 Sheat Title ROOF'&. @ CONFINED RI&E oIe: V - V !riglneering Prov4Ing for: DQt. 05 /06/01 V urIs •rL Vi P r' RvIIon snce nnuum The Grove Units ___ SA V • V 14661 Myor Road, Suite Ovrisre Aeeociotion r. • - V V Sheet No. V V Tuetin, Calif. c12106 Hosp y at El C.mIno V Real 114.734.0466 V FAX -754.055-T Carlsbad, C.A A26 - -- - V- • - V • 1 • V p. 14 - . STUD YALL FRAMING 2x SOLID BLKG. 11XCO OVER *15 FELT L CONT. 26 GA. 6.1. AEEP SCREED .COW. 26GAG.I.FLASHING SOLID &ROUT /ZLEROOF OVER 3O* FELT ROOF SHT& ROOF FRAMING r heat V4t7V4 CONFINED R117&E !nineerIng DroIng8 for: Date 0/06/0I The Ranolssonth Continuum The rove linits ReVIIofls orm SA 1.4661 !4yPord Rood. Suite G OINF1ØS AS9Ot1OF1 . Sheet No. Tustin, C.ollf. 412-706 Hasp Noy at El Camino Real 114.14.0466 A27 FAX 154.0531 Carlsbad, CA 4 p • -- - - •1•Ak _ - S -TILE ROOFING OVER * ROOFING FELT. 2x5 NAILER 6EEEEEEEE 2x2 NAILER RAKE TILE \ / 2x BARGE BOARD INSTALL BARGE DECPREE BEVELED EDGE DRIP ROOF FRAMING IX6 T*G SOLID $I-4!ATHING S-TILE ROOFING AT RAKE iii" = TI . . Engineering Drings for: Pat. 03/06l0 I The¼ ReroIs9onGe ContTrtuum The Grove Revisions orm GA Oyt41ø$ Association 14661 Myord Road, Suite C, . ', • Tustin, Calif. 412708 Hasp Y4oy t El Camino - Sheet No. - 0 • Real rn4.134.0466 A28 FAX 134.0531 C.rIsbGd, CA H-. - . ADDITIONAL CONT 2xBLK5 STUC<,O OVER #15 —N- FELT Al I I I ELASTOMERI DEC.KIN& I - PLY10'4P PECK SI4T& •- A ENTIRE SHEET Sheet Title. TLA5HIN& Scale: 3" = I'-O' "Incering Drcm" for: onto 01/26/01 The RónoIssance ContInun The &rove Units 14661 MyPord Road; Suite Co, Ovners Associotion GOMM P% - Sheet No. Tustin, Calif. q2'706 Hasp v4oy at El Camino Real ,• rn4.-134.0466 A29 FAX 734.0551 Carlsbad, GA I LINE OF P.C. CON. OPEN TO BELOV -'CAP ABOVE / P4.1. RAILING '(E) FRMcS' AS OCCURS - - I BRlDG ELAN ,- P.C. CONC. CAP TO BE I APO I4PC Br LITESTONE L ' I CONCRETE ' / TEL *IqqI5I ' - / RECESSED LT. FIXT. TOBE TAZZ LIGHTING MODEL KHO J BLACK, OR APPROVED EQUAL. Aa _ ENTIRE ' - - 53-4EEr ELEVATION Sheet cL)ARP RAIL. Title DETAIL °' is =11-091 Engineering Draw" for: two 0'7/26/016/oi The Renosonce ConUnuum 14661 Myford Rood, Suite C - 0v4ner5 Association !' d SPP Tustin, Calif. q2-10 - Hosp v4atj at El Camino '• Sheet No. • Real rn4-154.0466 A30 FAX 4.O! , Carlsbad, CA -. VS - 'hV• V I 1/2 SQ SE - - K::I"xI/2"!5TL BAR IM/*IOxI 1/4" R.H. V A40 SCRES @IS" O.C. * 1/2' SQ RAILS V Z V I V V V I" SQ ATANC.HION V V /@4s' O.G. MAX 4 V / I/2' SQ RAILS V - •. V• V 4" O.C. MAX " SOxS/lb" Sm V \ BASE PLATE \ (4) 1/4"P V C.ARRIA&E BOLTS V V SET IN FULL BED OF MASTIC------------------- V _ V A 3 V V ) ENTIRE ) 11/4' (V5 .4ET K L)ARIRAIL DETAIL Title Scale. r = '-0' The RenoIssnce Continuum e. c7rove, Units I466I Mord Rood, Suite C Oners Association V Tustin, Calif. Sheet • V Hasp 'Noy at El Camino ______ • V Seal 114.734.0466 S A31 -. V • V FAX 73.O531 Carlsbad, CA • V S -- S. Scole: NONE /I2/OI Revisions vote sP . 6/16I0 Pt4 - Sheet A-32 EXPANDED SCOPE OF V10RK -: STUCCO REPAIRS STUCCO REPAIRS ARE TO OCCUR YITH BALCONY FLASHING REPAIRS. SHEAR PANEL REPAIRS PLYYIOOD SHEAR PANEL REPAIRS ARE LOCATED ON THE LONER LEVEL OF THE BUILDINGS AT BUILDING ENTRANCES. -. SHEAR PANELS ARE TO BE EVALUATED ON AN • INDIVIDUAL BASIS TO DETERMINE: IF THEY HAVE SUSTAINED DAMAGE THE EXTENT OF THE DAMAGE REPAIRS TO SHEAR PANELS MAY INCLUDE BUT ARE NOT LIMITED TO FULL REPLACEMENT, PARTIAL REPLACEMENT OR RENAILING. DRY ROT REPAIRS PRY ROT REPAIRS ARE LIMITED TO EXPOSED FRAMING AS OCCURS IN CONJENCTION kNlTH BALCONY FLASHING REPAIRS. REPAIRS )4ILL BE REPLACEMENT OF LIKE FRAMING ON AN AS-NEEDED BASIS. ESTIMATED QUANTITIES . 7 THERE ARE 112 BALCONIES THAT ARE HAVING FLASHING REPAIRS. STUCCO REPAIRS OCCUR AT TNO SIDES OF EACH BALCONY. APPROXIMATELY S SQUARE FEET AT EACH END (S SF x 2 x 112) EQUALS 72 SQUARE FEET OF STUCCO REPAIRS AT BALCONIES. APPROXIMATELY 32 SQUARE FEET PER PANEL EVALUATION 1'NITH TI40 PANELS PER CORRIDOR (32 x 2 x 13) EQUALS 532 SQUARE FEET OF STUCCO REPAIRS AT SHEAR PANELS ,TOTAL ESTIMATED STUCCO REPAIR: 1,504 S.F. T0TAL ESTIMATED SHEAR PANEL REPAIR: 13 LOCATIONS TOTAL ESTIMATED DRY-ROT REPAIR: UNQUANTIFIABLE Sheet REPAIR SWFE OF VNOR< Engineering Dro'iirs For: The Reriaissonce Continuum The r'ove Units I4IMfor'Roo, Suite C Oners AssoGiotion Tustin', CIif. 210S • , Hasp V4cij at El Camino Real 1I4.134.046' FAX 4.0531 • Garlsbod, GA