Loading...
HomeMy WebLinkAbout2530 LUCIERNAGA ST; ; 82-101; Permit~ 5 a: j * i[ 0 u ~ ., 5 ~ w z ~ z 0 s z w .. " 0 u ., ir w "' a: ~ ![ O I hen 1lrm that I am llcensed under provisions Chapter 9 (commencing with Section 7000) of Division 3 of the Business arKI Professions Codfl, and my license is in full force and effect. L,c No ____ __ Class I hefeby alflrm that I am eJtempt from the Con- ~~o,;'~~~~~;:: ~d ~~,~~1~~~QJ/=:,\~r county wh1ch requires a perm,t to construct alter, improve, oemohsh, or repair any structure, pnor to its issuance also requires the applicant for such pel'ffl•I to hie a s,gned statement that he 1s licensed porsu-ant to the prov,s,ons ol the Con tractor's License Law (Chapter 9 commencing w11h Section 7CX)O of O,v,s,on 3 o! the Business and Pro-less1ons Codef or that ,s exempt therefrom and the basis tor the alleged exemption. Any v,ola!,on o! Section 7031.5 by an ;ippilcant tor a permit subJects tne appllc.inl to a civil penalty of not more than five hundred dollars ($500) □ l. ;JS owner ol the property, or my employees -.,th wages as the,r sole compensai,on, will do the wOl'k, and ,he structure 1s no! mt ended or olfered fo, sale (Sec 7o«, Business and Protess1ons Code The Contractor's License Law does not apply to an owneJ of property who builds or improves thereon and who does such work himself or through his own employees. provided that such improvements are not intende1 or offered for sale If. however. the bu1ldmg or improvement Is sold w1thm one year of complet,on, the owner-burlder w,11 have the burden ot proving tha, he d,d not Dl .. uld or ,mprove !or the ~ se of sale) ;JS owner ol the property, am exclusively actinQ w,th 1,censect contractors to construct !he pro1ect (Sec 704A. Business and Pro!ess1ons Code The Con!ractor's License Law does not apply to an owner of property who bullds or improves thereon. and who contracts for each proiects with a contractof{S) 1,cense pursuan1 to !he Contractor's L,cense Law! □ I am exempt under Sec for !his reason . B &PC 0 I hereby affirm that I have a cert,f,cate of cor,sent to self-insure. o< a cer1,!1ca1e of Workers Compensation Insurance. or a cert1!1ed copy !hereof (Sec 3800. Labor Code! POLICY NO COMPANY 0 Copy 1s !1led w,th the c,ty D Certified copy Is hereby turn,shed CERTIFICATE:. OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (Th,s section need not be completed 11 the perm,1 1s for one hundred dollars 1$100) or less) O I cert,ty that In the performance ot the worl\ for which this perrrnt 1s issued, I shall not employ any person 1n any manner so as to become sub1ect to the Workers· Compensation Laws oi Cal,forn1a NOTICE TO APPLICANT 11, after mak,nJ th1s Cert, locate of Exemption. you should t>ecome sub1ect l'J the Worl<.ers · Compensa11on prov,s,ons of Hie Labor Code. you must forthwith comply w,th such prov,s,ons or !h1s permit shall t>e deemed re~oked 0 I he,eby a!f,rm That There Is a cons1ructIon lending a,;iencv to, !he performance o! ttie work lor wh,ch th1s perm,i ,s ,ssued 1Sec J097. C,,il Cod~·- Lender s Name ___________ _ Lenoe,,. Address __________ _ USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA ANO DECLARATIONS. CARLSBAD. JILDING DEPARTMENT AP, ,JCATION & PERMIT 1200 Elm, Carlsbad, \.,dllfornia 92008 (714) 438-5!5~ BUS~NESS'L_ICENSE_# €.?..r-8% _CON,~AqtQR$-PNQN~4--ZONE 8]::..--Io I Pe.AMiT-NIJMBIA U~NO-PLAN 1.0. # BLDG U81 CODI 120<>9 ASSESS':)~ PA~G, STANDARD PLAN# .uc;.;::r-YI~ ·; .. I:. ' ., (~ -i,,.--YO N 0 ,o N Not Valid IJnlm Ad,;,u, Cllrtifi«I PLUMBING PERMIT· ISSUE EACH FIXTURE TRAP EACH BUILDING SEWER EACH WATER HEATER ANOiOR VENT EACH GAS SYSTEM 1 TD 4 OUTLETS EACH GAS SYSTEM~ OR MORE 1 I . \ EACH INSTA~ .. ALrER~REPAiR WATER PIPE ----_---- r EACH VACUUM BREAKER I -VI EACH ROOF DRAIN (INSIDE) TOTAL PLUMBING -r- ELECTRICAL PERMIT· ISSUE NEW CONST EA AMP'SWT DKR I PH 3 PH EXIST BLDG EA AMP1SWT/8KR ____ _ I PH 3 PH I REMODEL:ALTER P TEMP PO --~~RCUIT LE 2_Q_O AMPS -~ OVER_~oo AMPS ---- --+-TEM~~UPANcY (3~ -____l ----__ A_YS) --·;::;-~---- TOTAL ELECTRICAL -T - MECHANICAL PERMIT · ISSUE INSTALL FURN. DUCTS iJP TO 100.000 BTU OVER 100,000 BTU BOILER/COMPRESSOR UP TO 3 HP BOILER/COMPRESSOR 3-1~ HP II J I METAL FIREPLACE VENT FAN SINGLE 3. oo I SUMMARY/ACCOUNT NUMBER f --BUILDING PERMIT 01-00Q_-422 SIGN PERMIT 01~1)00-4221 PLAN CHECK 01-000-4806 TOTAL PLUMBING 01-000-4222 ELECTRICAL 01-000-4223 MECHANICAL 01-000-4224 '" . -II VI MECH HHAUST t;_'1Jll!"IY.CJ> . • I IP· -~ '"" ~ RELOCATIONOF~'"""",.r".,....... unn11ru 8 .. ,.,BILEHOME 01-000-4225 ov1uo1Lc;nOME PARK INSP SOLAR 01-000-4226 lOliH'lilE STRONG MOTION 65-640-0519 FIRE SPRINKLERS 01-000-:...4227 PUBLIC FACILITIES FEE 25-000-4933 SOLAR • ISSUE BRIDGE FEE COLLECTORS SCHOOL FEE · DISTRICT STORAGE TANKS Carlsbad 65-623-0519 ROCK STORAGE Encinitas 65-624-0519 PUMP San Dieguito 65-625-0519 PLAN CHECK FEE San Marcos 65-626-0519 ~1 l --F~=========±=+=i ====•~~u~~~ TOTAL SOLAR TOTAL FEES p,.,-ABLE - --- -1 HAVE GAREFULLY E>tAMtNED TI-IE COMPLETED "APPLICA.'nON At)H::IPERMIT",ANO 00 HE.Rf:av ~~J:A~l;;_R"-~-~::_ D:'cir ~~I :~~i::~~~~ ::o_f\:~~L-~~M~._- ~_;£vtfy·~tseuedby~~ffdi~icia1un(le,:.theptovi~·onso( ~-< Code Shaff e'lq)ltiJ ~ lim~-ai\ij bet(MM·lluu llf)d vokt,.Jf 1t\e"buikt_ inQ.,.. rk authprizedbySUCbpetmitiSnot_ c~wtthin1Mday$1romlhe · such permit, Ol if ti\&· l>Wfding or wo,k au1hodzed iby. ,: t):etmH ;~ or * Aft O$HA fl'EAltllT IS RE0UtRED ~ ixoA'U.TION&ONI -5' O" DEEP AND OEM0LfTIOtf OR 'CONStRUGllON OF STAUC1UfllES OIIER 3 STOAIES llf'HEIGHT 'lSSUEI>~.1:&,. , r •t1 N,\¼ ' AOO $TA')'E tAW$,G<lVeRN1tfG 6UILO¼NG COM-- 'ST . ·• . _ .. _ __. . . l<'.l~e~:t~A~-11'Y AND ·KEEP.. . . _. . . .. . ,}d:_C.L~ .COSTS ANO . "'· -.. . ' -_,__,..,,_,,---..;-., .... _.,,..,. .-..... ......,, OF THE '-.:....;. Uffll-ilftet -ill " . · l ~m'S ~~Uflff 'le CON1l!ACTOR e . · J (J, Mt• . If~ f" ~ 1 gq BY PHONIS (] A.PP~VED BY ~-• e * " I'-(/' ]! ii: i!' ., g_ ~ ... I l2 0 '-' E " £ a. i ,_. " C ii: 0 ., :l .. ., <( I ,. 0 'ai >- ,,; ., CD g a: ., .; □ E l'l C ., C u:: • -INSPECTION TYPE DATE INSPECTOR ;f;:;-JO( -BUILDING -FIELD INSPECTION RECORD q,J!Ul'Z, f'.J+ FOUNDATION REINFORCED STEEL • I REQUIRED SPECIAL INSPECTIONS INSPECTOR'S NOTES OA:::-1 --0 9-;17-83 f_ . . INSPECTION REQ IF INSPECTORS DATE MASONRY CHECKED APPROVAL GUNITE OR GROUT SOILS COMPLIANCE ~·~ ~ // __ ,,...,.. /,,<~4'17<~ .,t:..-,a,4g~ .. Z/,<7&/ ~/) /7/<'/o~ FLOOR & CEILING SUB FRAME /1 PRIOR TO ' '-m RE.... ,,,, ~' /~Mill~ ,f/5;e:eZI iilli~0_ . lq_7_9-3 ,,,, FOUNDATION INSP SHEATHING STRUCTURAL CONCRETE FRAME "',l< ~/.,-/~./J J/5/F4 ,µ; (~) OVER 2000 PSI ,,, j,,(/df n, .I t9LEAJ",.ti;/t1r Ch'C-<L;. -z;z/4f,e' C4A"~~ PRESTRESSED EXTERIOR LATH I ,,,uN -'-. CONCRETE ,. ~~ n.-,M..,... /,e,rr A// ,,.,..crr/,..,z,,. If Cov_t:✓.:? 11',c -5.--~ /. / ,, (s) POST TENSIONED ~ A /.&E"/J /A J< F INTERIOR LATH & DRYWALL I I -CONCRETE , PLUMBING / / -f( A&I/Uc' ,,,,,; //,/,N 7 --FIELD w·ELDING I SEWER AND BL/CO r, HIGH STRENGTH , ' I PLUMBING UNDERGROUND 'J-1:i.-PJ Ii (It) BOLTS , PLUMBING TOP OUT .,_1~. f SPECIAL MASONRY If"-,/ VLL TUB AND $HOWER PAN A / 115/y,1. r 00 GAS TEST -PILES CAISSONS ELECTRICAL I ; TEMPORARY POWER , ELECTRIC UNDERGROUND ROUGH ELECTRIC ,J..,/ J-4 -i rifi ' - ELECTRIC SERVICE I I I ' -. . -• ..._ --. BONDING G. F. I. -SMOKE DETECTOR MECHANICAL /l ----·· DUCT & PLEM., REF. PIPING ' 1/,.-Ju. 7, (i}) HEAT -AIR COND. -SOLAR SYSTEMS / I , I -. . VENTILATING SYSTEMS CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HA VE BEEN APPROVED. ----- JOB SITE FINAL -- PLUMBING ' ELECTRICAL '-/1 MECHANICAL '-,, I I,_ , 17' --- GAS "'-11/!J.IJ• • I ' - BUILDING ....,_ I VJ SPECIAL CONDITIONS CERT OF ocr \NCY ISSUED -J / To: FIRE, PLANNING, ENGINEERING t,/ FINAL INSPECTl~~W-7 _gy ~ress 2t>~,J -;;tS-]d ici,,,~ 1 t,. _,, (A?,,J Type of Constructlon1 _____ ,~t,.AJ<-•-..r.L------- Person to Contact ~ ~ Ph. No.<f3J'--i9'JJ Remarks: __________ c->-_'J-'i/'-;)--'-.2:....c.<.7..,.J:='3 Date _ _.Jt.j'...,_-..a.P_--_____,_J,__4 ________ _ Approval _ ___,_fhn~.LL{,a,""'7...L.L>&-1/""--'-"~------- , To: FIRE, PLANNING, ENGINEERING _ FINAL INSPECTION 0/~ Date I {J1 Address d sv¢,Jo ~Ian# ,-P..2-10 / I Type of Constructloo~A=--~~""7""'--_______ _ Person to Contact J/?J-.--: ~ Remarks: ______________ _ Date~$~~ Approva:~'~ I N s p E C T I 0 N R E Q u E s T I N s p E C T I 0 N R E Q u E s T 82-/CJ/ ESGIL CORPORATION 9320 CHESAPEAKJ<: DR., Sl'ITE 122 SAN DIEGO, CA 9212:l (714) ~00·140H L (.) CI t;-"7e fJ /-}~ y:} s,. ,, (i) ~V--l~ 1):,orz.,L01\,\.Ji)u..U ,, Yk tT2 G,-s,f,,,,...e.J-~1 +v ''. .. ,q. \IV\ , vi I VVI v VV\ 0 ,= 1 3 • 7 -:;-,¾, <'.11"" \c:-, ~vt., 0vt -~,"' 1 v4- w, tv oo ~ S.\i1"}1..-L 11 /rr-~-:-;-(o~~ be ~.1vvtct 'ale .. ~ ~ . ~ ' ~ , etitp of etarlsbab .TURISDICTION: CA-Rh! l4 D DATE. ____ _ ?P.OJEC':' ADDRESS: L. ltl c I fR, /IA G, 6 er TO: _______________________ _ PLAN CORRECTION SHEET SINGLE FAMILY AND DUPLEX DWELLINGS PI an Check No . __ .....,8'-='2.=---__,/c.:0~/ _______ _ rldte plans received by jurisdiction ':/· 2 ·82..:: :->ate plans received by plan checker~-• 'I~ Date initial plan c heck completed 4\ 1 l-, by' ? fC)RE\,0RD: PLEASE READ D APPLICANT COPY < CITY COPY > D PLAN CHECKER COPY /. Submit f~lly dimensioned plot plan drawn to scale showing loc3tion size, and use of all existing and proposed structures" on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes and approximate finish floor elevations for all structures and show elevations at all corners. Sec. 302(b)7. ,;. Indicate distance from center-line of street or alley to property line and distance from curh to property line . Sec. 302(b)7 Plans, specifications and calculations shall be signed by a California State licensed engineer or architect. (California Business and Professions Code) n . Fin•: PROTECTION / Wa 11 s closer than 3 feet to property lines shall be one-hour fire-rated construction, have no openings, and shall have 30 inch parapets when the building floor area exceeds 1,000 square f~et on any floor. (Table 5-A Sec. l 709(a) _y Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Sec. 1710 and Sec. 504(b) /· Projections, including eaves,shall be one- hour fire-resistive construction, heavy timber or of non-combustible material if they project into the 3' setback 3rea from Plan check is limited to technical requirements 1..._ the property line. Sec. 1710 contained in the ~niform Buil~ing Code, Uniform r r /~ Plumbing Code, Uniform Mechanical Code, National ( 5e.r;. ~ Show location of p.:!rn,,1nently wir,,d smoke Electrica; Code ~nd state la~s regulating energy rt,JI\JJ(p dr•t,:ctor. Sec. 1210 conservation, noise attenuation and access for ~f r ~/ the handicapped. The plan check is based on. ,_.....,,----;. , .. ROOM SIZES, 1,rc1rr. v~:NTILATfONS AND GLAZING regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planni ng Department, Engineering Department or other departments. The items circled below need clarification, modification or change. All circled items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (cl, 1979 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. (j Please make all corrections on the original tracings and submit two new sets o! prints, and any original plan sets that may have been returned to you by the jurisdiction, to: 8Wt4 Q tA!(i QE)>A R14t r 4/7 To facilitate rechecking, please identify, next to each circled item, the sheet of the plans upon which each correction on this sheet has been made and return this c heck sheet with the revised plans. Indicate on plans the name of the legal owne r and name of person respons~QL the preparation of the ~l~ Sec. 302(b) /4' One room must cont a in ,1 r,,ini,num of I SO square f•iet of superficial f loor areol . Sec. 1207(b) l~b,table rooms, othe r than kitchens, shall contain at l east 70 square feet af floor ~rea. Sec. 1207(b) ),If~ Window area must ~eat least 1/10 of the fl oor area and a minimum of 10 square feet per Sec. 1207(a). Appears to be deficient in Openable window area must be 1/20 of the floor area and a minimu~ of S-square feet. In bathrooms, laundry rooms and similar rooms. Minimum is 1.5 sq.ft. (Sec.1205(a) •191 One-hal f of all required window area must be openable in (, 1 Tc /./ r , 1 / f> ,.,., •ltq G,'4rtOOv I U • oD~ ., o{i-hn~i-0~ cla/\ ;f,,J,,, rovide mechanical ventilation capabl e of roviding five air changes per hour in '0 A. 'f'H I athrooms , water closet compart:nents, laundry v • rooms and similar rooms if required windows arc not provided . Sec. 120S(a) 1V. No habitabl e room, other than a kit.Chen, ✓-s hall be less t han 7'0" in anv di:nension. Sec. 1207(c) · Show that ceiling height for rooms is a minimum of 7'6". \., . r( I I :' 1..1 { /)( habi+.:able Sec. l207(a) Show ceiling he i ght for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0". Sec. 1207(a) y.'Provide 30" clear width for water closet compartments and 24" clearance in front of water closet. Sec. 17ll(b) No cooking room shall be used for sleeping purposes, unless complying as an efficiency living unit. Sec. 1208 yr. Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Sec. 5406 @Glazing in shower and tub enclosures (includin9 windows ) shall be tempered, laminated or approved plastic. Sec. 1711 (f)(g) Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". Sec. 1204 ~-Eaves and cornices may not project into a required yard more than 2 i'nches for each foot of yard width if required windows open into the yard. Sec. 1206(d) ,,,t<f. A mezzanine is an intermediate floor and may not have a floor area exceeding 33 1/3 percent of the total floor area in the r oom below, and the mezzanine floor must have D. a clear height of 7 feet, above a nd below,and must have 651 of the long s ide open to the room below. The loft you show does not comply as a mezzanine floor and is, by Building Code definition, a story ______________ _ eXITS, STAIRWAYS, AND RAILINGS Floors a bove the second story shall have not less than 2 exits. Sec. 3302(a) Required exit doorways shall be not less than 36" in width and not less than 6'-8" in height, and shall be capable of opening at least 90 degree s . Sec. 3303(e) ~ Provide 36" high protective railing for porches, balconies, and open sides of landings. Ma ximum opening between railings shall be l ess than 9". Sec. 1716 A. Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a r ight angle to the top rail. Table 23-B y. Provide stairway and landing details. Sec. 3305(b) & (cl /_ Maximum rise 8" and minimum run lS 9". /4 Minimum head room is 6 '-6". /. Minimum width is 30". ><f'. Handrails shall satisfy the following: ~- A'2. ,$-1 . Provide handrail for stairways over 30" high when serving a single dwelling. Title 24, Sec. T25-22(b) Handrail shall be 30" to 34" above the nosing of treads. Sec. 3305(j ) Handrail projecting from a wall shall have a space not less than l 1/2" between the wall and the handrail. The hand grip portion of handrail shall be not less t han l l /4" nor more than 2" in cross-sectional ,dimension. Sec. 3305(jl (see attached ) Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairway width. Sec. 3305(g) A door may open over a stairway landing provided the door, in any positi on, does not reduce the clear area of the landing, in the direction of stairway travel, to less than one-hal f the required width of the stairway. Sec. 3305(g) A door may open inward at the t op step of a stairway provided the top step is not more than 7 1/2" lower than the floor level . Sec. 3 3 0 3 ( i ) 2 54. Provide detai ls of winding stairway. 5Y. S'L ,o. a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from the side of the stairway. b. Maximum rise is 9 i nches . c. Minimum width i s 30 inches. Sec. 3305(dl (see attached) Provide spiral s tairway details: a. Minimum run i s 7 1/2 inches at a point from where the tread is the narrowest. b. Maximum rise is 9 1/2 inches. c. Minimum headroom is 6 feet 6 inches. Sec. 3305 (f l (see attached) Sprial stairways may not be used for required exits when the area served is greater than 400 sq. ft. Sec. 3305(!) Spiral stairways must have a clear walking space of 26 inches between t he column and handrail. Sec. 3305(£) Provide I.C.B.O. Reasearch Report and Number for metal stairway, or submit plans and calculations and approved fabricator registered with the Building Department or note that the stairway fabrication shall be done under special inspection per the approved fabrication plans. Sec. 306(a )4B and Sec. 306 ( f) In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the e xterior wa l l below or ~ithin 10 feet horizontally of an exterior stair- way . An exit balcony with 2 separated stairways LS exP.mpt. Sec. 3305 Exterior st~irways shall not project i nto the J foot setback from the property lines. Sec. J305(nl ~~e walls and soffits of the enc l osed useable s pace under inter1or stairs shall be ?rotected on -~he enclosed side as r equired for one-hour f1r~-resist1ve construction. Sec. 3305(m) ,,J .. 02: Show 1 3/8" solid core self-closing door for openings between garage and dwelling. Sec. 503(d) 103. Garages are not permitted to open into 62. Min1mum construction specifications shall be made a part of the approved plans. (See attached ) a room used for sleeping purposes. Sec. 1104 Openings between carport and residence require self-closing doors and stationary windows. Sec. 1214 E. ROOFING ( ,..-) )(105. Show garage framing section, size of header -.,( specify roof pitch. tf]-.-,, t over garage opening, l,!teral cross bracing /Y• ..,,.. at ~te l1ne and method of bracing garage y. Roof pitch is not adequate for roof type front. Chapter 23 specified. Specify minimum pitch of_____ NOTE: Minimum plywood diaphragm ratio is 3 1/2 to I or 2'8". Table 24-I ,>r. Spec ify roof material and application. ;,.c,(.' ~'ll SpecifyCJ C B,O !2,Proval !!.l!ll)~or....r~ L7 materials not covere01n-uec.l~,<),,1 VA L t 11L c ~ J,<:' Specify roof slope for drainage ~r design ( f~f.f.t to support accumulated water. Sec. 3207(a) 1 5 '-Show roof drains and overflows. Sec. 3207(a) ,, itM / Provide skylight details to show compliance w1th Sect1ons 3401 and 5207 or provide IC30 approval number. {Ij ?rovide plastic roof panel details to show compliance with Se~tion 5206 or provi~ ~ - ICSO number. (3 R I~ r oL T,f'f-,• Ll t C JS IC8'J \....:\_ J.-08"'. y. Show attic v·entilat1on. Minimum ~vent area t/. z,q.:_'1) is 1/150 of attic area or 1/300 of attice R. area if at least 501 of the required vent µ,r. is at least 3 feet above ceiling joists. Sec. 3205(c ) MASONRY Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Sec. 3707 Show veneer support and connections comply with Sec. 3002, 4,5,6, and Sec. 2516(a) regarding ties and 19 wire in horizontal joints or note construction to be perattached sheets 30-1 or 30-2. H. _µ-,-. Doors between dwellings and attached garages may swing in either direction provided the difference in floor elevation between the dwelling and garage does not exceed 1 1/2 inches and provided the door is not used as the primary means of egress from the building. If the difference in floor elevation exceeds 7 1/2 inches, or if the door is used as the primary means of egress from the building, additional steps or landing must be provided i n accordance with stairway requirements, and the door must not swing over the depressed level. (see 3303(i)2 and 3305 (g). Provide 18" raised platforms for any FAU, water heater, o r any other device which may generate a flame or spark. Note that continuous fire wall protection shall be installed behind raised platform(sl prior to framing platform. FOUNDATION REQUIREMENTS Note on plans that"A soils engineer shall eva1uate any unantic ipated uncompacted fill o r expansive soil or other soil problems disclosed during construction". Sec.306(a)l2. Submit soils classification determination by a licensed engineer or architect based on observation, tests, borings, or excavations, and containing comments on the degree of expansiveness, compressibility and bearing value. Sec. 2905 ,>9-::""'show height and construction details of all masonry walls. Chapter 24 ))-i"· Note o n the plan the soils c lassification, whether o r not the soil is expansive, and ~Note that cleanout openings shall be'provided at the bottom of all cells to be grout filled over 4 ' in a single pour. Cleanout shall be sealed before grouting, after inspection. Sec. 2415 Y, Show floor and roof connections to masonry · walls. Connection shdll resist 200 pounds per l ineal foot or the actual design load, .,,,.. whichever is greater. Sec. 2310 ~-Provi de material specifications for mortar, grout, masonr y and reinforcing steel. Sec. 2403 ,,y{: Show how masonry house walls retain1ng earth are to be waterproofed. Provide detail . Note that special inspection of the masonry w1ll be required for ____________ _ G. GAR.a.GE AND CARPORTS >°1'.Garage requires one-hour fire protection on the garage side of walls and ceilings common to the dwelling. Table 5-B Sec.503(b) ~.Al l elements supporting floor above garage to have one -hour fire-resistive protection o n the garage side. Sec. 50). Beams and posts, not w1t h1n t he wall or ceiling con- struc~1on, must comply wi th UBC, Tab!~ 4)-A, or be m1ni mum 6" dimension beam and m1n~mum 8" by 8" post. note the alJ.owable bearing value. Sec. 2905 The foundation plan does not comply with the soil report recommendation for this /'/ project -So /L. s 8£ to8 T I ufcu V + - 1 -;tt<,1.d l xG -10µ0 w ,,,n , d:T 6AtA6F ) ,;; (.. A f, OIIJ ,; H '[, ,s.. / ~ Provide notes on the foundation plan listing the soils report recommendations for foundations. slab and building pad preparation. Note on the foundation plan that "Prior to the Contractor requesting a Building Department foundation inspection, the soils engineer shall advise the Building Official in writing that: l. the building pad was prepared in accor- dance with the soils report: 2. the utility t renches have been properly backfilled and compacted, and: 3. the foundation excavations, formi ng and reinforcement comply with the soils report and appro ved plan." Provide spread loads des1gned or per bearing an enginee r or footings for concentrated for l,000 PSF soil bearing value as determined by arch1t cct. Chapter 29 ✓ Y,· _µ-r. Show height of all foundation walls. Chapter 23 Show height of retained earth on all foundation walls . Chapter 23 Show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29 ~ote on plans that wood shall be 6" above finish grade. Sec. 2417(c) 7. Note on plans that surface water wi ll drai n away from building a nd show drainage pattern and key elevations. Sec. 2905(f) Dimension foundation per Table 29A. TABLE NO. 29-A-FOUNDATIONS FOR STUD BEARING WALLS-MINIMUM REQUIREMENTS DEPTH OF FOUNOATION WIDTH TNICIINESS IELOW NUMllR THICKNESS OF OF OF NATURAL OF FOUNDATION WALL FOOTING FOOTING SUlfACt STOIIES (laclles) (IDCftts) (lncftts) OF l",IDUND ANO FINISH CONCIETE UNIT GHDE MASONIY (lnc~ts) - l 6 6 12 6 12 2 8 8 15 7 18 3 10 10 18 B 24 XOTES: Wbe~ unusual conwtion• or frost cooditions are found, footings anti lound.,tions <hall be :as required in Section 2907 (11. The around under the Boor may be ••cavated to the ,-le,·atoon of th, top nf the loot1n~. .132 . Show !oundation sills to be pressure treated, or equal . Sec. 2517(c) 3. @ Show foundation bolt size and spacing. Sec. 2907(e) _, Note cross bridging or blocking. Floor joists and rafters more than 12" in depth and spanning more than 8 feet shall be ~uppor ted laterally by bridging at intervals not exceeding 8 feet. Sec. 2506(g) 163. Show blocki ng at ends and at supports ' of floor ·joists, and for rafte rs at exterior walls. Sec. 2506(g) ~- Show solid blocking at ridge line and at exterior walls on trussed roofs. Sec. 2506(gl Show double joists. Floor joists shall be doubled under bearing partitions r unning paral lel with the joists. Sec. 2518(d) 5 Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center wher e rafters and ceiling joists a r e not paral lel. Sec. 2518(h ) 16] Show rafter purlin braces to be not less / • than 45 degr ees to the horizontal. Sec. 2518(h) ,/show 1/2" minimum clearance between top / 0 plate of interior partitions and bottom chord of trusses. (To e nsure loading will be as designed.) Show double top plate with minimum 48" lap splice. Sec. 2518(g)4 Show nailing will be i n compliance with Table 2S-P. Provide f ire stops between stories, between top story and roof space, at cei lings and floor levels in interior and exterior walls, in mansard roof or eyebrow so no concealed or furred space is greater than 10' horizontally or verti cally, between stair stringers at top and bottom and- --m!tw e n stuas -arong ancf-i"n l rne wTtfi'"~ . scafrforl adjoln1.ng stud walls aru! partitions , at perimeter of sliding door pockets,·· between chimney and wood frame using metal or i ncombustibles for the fire stop and at other places that could afford passage --137:\ Specify size, ICBO number and manufa&turer f 1Jt..-1'1 ~ ot power driven pins. Show edge and end fl \SO !t /$ j distance and spacing. Sec. 306 (fl l \. l'l')O )% of flame. Sec. 2517(fl Show stud size and spacing. Maximum allow- able stud heights: 2"x4"@ 16" is 14': 3"x4"•2"x6"@ 16"o.c. is 20'. Sec. 2Sl8(g)2 135 Show size, imbedment and location of hold ' / •u/ down anchors on !oundatio~lan . se·c. 23l2(fl ~-Note on plan that hold down anchors must ),M. be tied in place prior to foundation inspection. Note an A.I.T.C. Certificate of Compliance for glued laminated wood members shall Sec. 2312(f) ;l-37. Show adequate footings under al l shear walls. Sec. 23ll(e) ;)6. Show stepped footings for slopes steeper than 1:10. Sec. 2907(c) yt\. ;,,<2 . Show minimum 18" c l earance f rom grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Sec. 2517 Show pier size, spacing a nd depth i nto undisturbed soil. Table 29-A Show minimum under floor access of 18"x 24". Sec. 2517 Show minimum under floor ventilation equal to l 1/2 sq. ft. for each 25 lineal feet of exterior foundation with openings as close to corners as practicab le to provide cross ventilation on at least two approximat ~ ( ly opposite sides. Sec. 2517 ( .,_f; ..,_ r'· be given to the Building Inspector prior to erection. Sec. 306(fl Detail all post to beam and post to footing connections. Sec. 2517(c) 4 Specify nail size and spacing for all shear walls , floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. (Tabl es I,J,K). Show J"x4" or 2"x6" studs in first story of three story building. Sec. 2518 (f ) 1'(11. Provide truss details and truss calcul ations . p-t{. Provide roof framing plan. Sec. 302(al7 179. Provide frami ng sections through ______ _ Section 302(a) 7 I. "/,t•· FRAMING f,.~ ~ & Speci fy all header sizes for opening over 4' wide. Sec. 2518(gl 7 Provide calculations for l,19--fL.:rrJ2R-'L Show all joists, rafter s, beams, and posts 2• to 4" thick to be No. 2 Grade Douglas Fir-Larch or bette r. All posts and beams s· and thicker shall be No. l Grade Douglas Fir-Larch or better. (Table 25-A-l > Show wall bracing. Every exterior wood stud wall and main cross partition shall be braced at each end and at least every 25 feet of length with lx4 diagonal .J .. ---. let-in brace or equivalent. Sec. 2518(g)S, r,l,A.. , , J L S ') ""\-o C... k tJ ... , 1 ; ! 1e ') "' IJ 1 : 1 I ------ ..182. ), • ' -; ,. I 1 •~1nS., Section 302(a) 7 In areas subject to water splash and in exterior l ocations, wood columns and posts shall be supported by piers projecting at least 2" above the finished grade and shall bear on a metal base plate or treated wood unless the columns or posts are foun- dat on grade ~edwood or cedar. Sec. 2Sl::J(cl4 \9 ' i'") ',"'."HA .. \ V $1-:.e~ ,'-4,~i~e '10V L,s;,..L -'"<.::!~ .... "')'•>te ~ ~o ~ ~~--°:!-(._::::-1?_ ; yr. J><· y!. ;,w: ;Y- r- ~ Show location of attic access with minimun size 22" x 30". Sec. 3205 Show draft separation for attic are as in excess of 3,000 sq.ft. Sec. 3205 Show draft seoaration for space between dropped ceilings and floor above in excess of 1,000 sq.ft. Sec. 2517 Specify plywood grade and panel indenti- fication index. Table 25-J When roof pitch is less than 3:12, design ridge as a oeam. Sec. 2518 (h) Wood shear walls shall not be used to resist horizontal forces contributed by masonry in buildings over one story in height. Sec. 2516(b) Gypsum lath and plaster, gypsum sheathing board and gypsum wallboard shal l not be used in vertical diaphragms to resist for ces imposed by masonry or concrete construction. Table 47-I If cripple wall studs are le!s than 14", framing shall be solid blocking. Sec.2518(g )6 Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Sec. 2518 (g)6 Show plywood sheathing over exposed eaves, or other weather exposed areas, is exterior grade. Sec. 2517(gl 3 Show a weep screed at the foundation plate line on all exterior stud walls to be stuccoed. Sec. 4706 (el Provide an approved waterproof building paper under wood siding. Sec. l70l(a) Specify an approved flashing for exterior openings and parapet walls. Sec. 3208 196. Show corridor width to be minimum 36". J,rl· ~- ~- Sec. 3304(bl.' Specify truss layout for 30" x 30" attic access. Ridges , hips, and valleys shall be at least one size larger than supported rafters. Sec. 25l8(hl 3 Provide metal straps across ridge beam and rafters . J. MECHANICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uni form Mechanical Code. A"oo'\ Show the size, location and type of all c::;;,;' heating andc oollngappliances or systems. .,)M'. Show source of combustion air for furnace will comply with Chaper 6, U.M.C. .J1>?.. Every dwellin:J unit shall be provided with heating facilities capable of maintain- ing a r oom temperature of 70° f . at J feet above the floor in all habitable rooms. Show basis for compliance. UBC Sec. 1211 Show minimum 30" deep unobstructed working space in front of furnace. Note on plans.clearances to be per manufac- t urers listing. Sec. 704 UMC furnace shall not be installed under any stairway . Sec. 704 UMC furnace shall not be installed in any bedroom, bathroom, closet, or in confined space with access o nly through such room , unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Sec. 704 UMC Show ICBO approval for prefab fireplace and pr ovide approved installation i nstructions at job site. ~ Show access to the attic or under floor ~ furnace to be minimum 30 inches by 30 inches. Sec. 708 & 709 UMC .,. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide. Sec 708 UMC Show permanent e lectrical outlet and lighting fixture controlled by a switch for the attic furnace. Sec. 708 UMC Show details to comply with Section qo9 for furnace under the floor, Section 708 for attic furnace, or Section 710 for roof or outside furnace. Note on plan, gas vents and non-combustible piping passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC Sec. 1706(a)6 K. ELECTRICAL (National Electrical Code) All wiring shall comply with the National Electrical Code. Note on the plan the amperage of electrical service. If the electrical installation is more than 200 amperes, show panel location and provide a single l ine diagram and load calculations including: a. Wiring method employed. b. Sizes of all conductors, switches, circuit breakers, fuses, and conduits. c. Approximate length of service feeders. d. Provide plot plan showing services, all panel l ocations, circuit arrangement and load distribution on panel busses. e . Provide typical panel schedule(sl. Dwellings require minimum 100 amp service. Show location of all electrical receptacles. Electrical receptacle locations and/or spacing is not adequate in PtNt.v;, {Vfll,; ttl, PPt?III H Pf 'n 1-O bP¥ 3 At least one receptacle shall be installed outdoors, in basements and attached garages, other than laundry outlets. Art. 210-25(b) Show minimum dwelling lighting (NEC Art. 210-26(al and GfI 'S in ~arage, baths and outdoors. NEC Xrt. 210-(a). Note "UFER" ground to be provided (NEC). Art. 250-81 PLUMBING (Uniform Plumbing Code) All plumbing shall comply with the Unifrom Plumbing Code . m. 23;'_) 2 4 3 .) Show water heater size, type and location on plans. Show method of providing combustion to fuel burning water heater. Sec. air 1307 fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom. Sec. 1309 Provide adequate barrier to protect water heater from vehicle damage. Sec. 13'10 Show T and P valve on water heater and show route of discharge line to exteri or Sec. l007(el Provide dryer vent to outside . UMC Sec. 1903 Note on the plan that hose bibbs and lawn sprinkler systems shal l have approved ba ckflow prevent:ion devices. Sec. 1003 Shower stall shall accomodate a JO"circle and have a minimum floor area of 900 sq.in. UPC 909(dl ,· ~- N. y 273. @) ~OISE INSULATION (DUPLEXES) Show details of duplex common (par~yl walls and floor/ceil1ng assembl1es to ach1eve a Sound Transm1ssion Class (STC) rat1ng in walls of SO decibles and an Impac~ Insulation Class (IIC) rating on floor/ ceiling of SO decibles. Title 25 Show how penetration of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 25 Provide insulation in walls and ceiling to achieve STC of SO between garage and living area if garage use is not controlled by resident Title 25. ENERGY CONSERVATION All additions to existing residential bu1ldings must comply with Title 24 energy regulat1ons. Additions exceeding 30\ of the existing building requires the existing and addition to have R-19 ceiling insulation if the existing ceiling area is accessible for insulation installation (T20-l40l(c). Specify the insulation R valves for walls, roof and ceiling. (R-11 for wal ls: R-19 for ceilings, or provide details and analysis for alternate design. T20-1403 Table A, 28. Specify the gros• floor area or heated portions of the dwelling, and the area of glazed openings on the plan. (T20-l430) Provide an analysis justifying increasing the single glazed area beyond 161 of the gross floor area. Show method to reduce heat loss to that which would occur with basic glazing. (T20-l402,def.) Provide energy analysis to show that the bonnet capacity of the gas central furnace does not exceed the building design heat loss by more than 301. (Exceptions: 48,000 BTU Hr. output furnace. See also California Efficiency Adjustment.) T24-l404 Note on plan that all tranverse ducts, plenums, and fitting joints of HVAC system shall be sealed with pressure sensitive tape or mastic to prevent air loss. T20-l404 Note on plan that insulation of ducts shall conform to UMC Section 1005. (T20-l404) ~-Note on plan that all doors and windows to the exterior or to unconditioned areas shall be fully weather striped per ANSI Standard. (T20-1403). ~- ~- Note on plan that back draft dampers are requir&d on all fan systems exhausting air from the building. T20-1403 Electrical resistance space heating shal l not be used unless: a. 60\ of heating/cooling is supplied by a nondepletable source. b. supplements a heat pump system. c. less than 10\ of total heating system. d. life cycl e cost analysis justifies. T20-l404 Note on plan that all heating and cooling equipment efficiencies shall conform to Title 20-Chapter 2, Subchapter 4, Article 4. (75\ for forced air furnaces). Note on plan that no natural gas, central heat1ng plant may be installed without an Interm1ttent Ignition Device. Tl0-1405 Ele c~ric ~esistance wate r heat1ng 1s not permit t ed unless verf ied as cost e ffective by a l ife cycle cost analys1s. T20-l406 NOTE: 0. )l)t. / (Joi ) Outdoor pools with fossil fuel heaters require pool covers as well as other energy saving devices such as time clocks, etc. T20-l406 MISCELLANEOUS Show a minimum 2" air space and flashing between planter and building walls. Sec. 251 7( el Specify material to be used under the shower tile. Sec. 1707(a) ~ Specify lath and plaster to comply with Chapter 47, use. , 30 "') Two 3/4" copper pipes must be i nstalled from water heater location to convenient location of future solar panels (City Ord.) ;os. Provide sleeves (roof jacks) in roof for two future 3/4" copper pipes to cunvenient location of future solar panels (City Ord.) Note that solar water piping is to be insulated in areas that are not heated or cooled. (City Ord.) See attachment for roofing requirements. The plans were reviewed based on the information shown on the plans. If the plans are in error, or changed during construction, the permittee shall contact the Building Department for review and prior approval before proceeding with the work: --7 0 Building plans are substantially correct and complete. By: __________________ _ Date: __________________ _ 0 Building plans would be substantially correct and complete if minor corrections are made at counter. By: _________________ _ Date: __________________ _ ii Building plans require major corrections and by plan check If you have any questions regarding this plan check, please -:all ✓-;-'vy3 atl14 ,:1oi '1J0t;,. We . .,oul d also be pleased to meet with you, at no charge, if addit1ona l assistance 1s needed. Ordinary roof coverinys may be used only on buildin~s of Group M occupancies . (City Ord. 809)) Fire-retardant roofin~ is requi red on all residential dwellinl's r,er City Ord. 809). 1979 EDITION UNIFORM BUILDING CODE 3203 (e) •·irr-rrlardanl Roof Covtrjngs. A f1re-re1ardan1 roof l"ll\"Crinf ~hall he any one of 1he following roofings: I A.n~ Cla~, A or B huill-UJl roofing a,,embly. ., An~ mineral aggrega1e ;urfaced built-up roof for arptica1ion 10 roob ha\ mg a slope no1 more 1han 3 mche~ hl 12 inches applied as ,pe.:if1ed m Section 3203 (di I consis1ing of not less than the I ollo" mg: Roof Orel. Solid ,urlace o n noncomhus1ible ma1erials or minimum of ':-in.:h pl Y" ood or I -inch nominal board; or or her ma1erial appro\·ed by the build mg official. Ba~r Sheet and Plirs Four layer, o f Type 15 perforated organic fiber felt. or Three layer, o f Type 15 organic o r inorganic fiber felt, and !,urfadn)? Mau•rial 4()(1 r<iund, per roofing square of gra, el. crushed rock. ceramic or arrr,n ed ,imilar surfacing material. or 300 pound, per roofing square of crushed slag. l~ee L". B.C. 51andard No. 32-5 for mineral roofing aggrega1e "eigh- 1ng les~ 1han 6ll pounds per cubic foot. I J . An} buih-up roof for applica1ion 10 roofs ha\'lng a slo pe 1101 less 1han ·: m.:h I() I:! inches applied a; specified in Sect1on 3:!03 (di I, comisung of no1 less 1han the folio" ing: Roof Deel. Sohd surfa.:e on noncombus1ible ma1erials or minimum of '!-inch plywood or I-inch nominal boards or orher ma1erial appro,·ed by 1he building official. Bast Shtrl and Plits 1" o layer~ of Type 15 organic fiber felt, or One layer of 14-pound glass fiber fell base sheet, or combination ;heel, or One la)·er of Type 30 organic fiber fell. or One la)er of Type 45 asbestos fiber felt base sheet, and Cap Sherb One layer of 90-pound mineral surfaced organic fiber felt .:ap sheet (requires no1 le;s 1han two layers of organic fiber felt), or T"o layers of 55-pound mineral surfaced organic fiber felt split sheet, or One layer of 80-pound mineral surfaced asbestos fiber felt cap sheet, or ( >nr la\e1 ol 72 pound 111111<·ral \IHlan·d 11la" f1h<·r fl'l1, ,1p ,1"·,·1. "' I wo la,rr, ol 1 VP<' I~ a,hr,11" hher fml\h11111 frh,. 4 Any ('la" A ,,r II prrpared roohng ~ Any {'la"< mmeral ~urlaceJ a,phah ~h1n11te, laid ,11 1ha1 th<·1c a1<· no! le" 1ha11 1"" 1hid.ne~,c, al an~ pom1 and the 1111al wci)!hr rl·r roorm!! ,quarc •~ no1 le" than :!35 pound,. t,, A~heMO,-l·emem ~hm111c, or ~hcct, 7 ( ·oncretc ~lah rout. k. Me1al roof covering Y. Slate ~hmgle,. HI. Cla) or .:o n.:rc1c roof tile 11 . Any wot i:o\'crmg ~> ,tern, ul "ood shmgle~ or ;hakes ha, ing a Cla~s B ra11ng. A Special Purpose Roof complying with UBC Standards tlo. )2-14 may be used provided the building is, (1) not more than two stor ies in hei~ht1 (2) not more than 6 ,000 S.F. of projected roof area; and()) there i s a mi nimum of 10 feet from the extremity of the r oof t o the property lines on all sides. (City Ord. 809)) UNIFORM BUILDING CODE STANDARD NO. 32·14 SPECIAL PURPOSE ROOFS Wood Shakes and Shingles with Asbestos Felt SK. 32.1401. (al Wood Shahs. Special purpose wood shake roofing shall .:on- form 10 grading and applica1ion requiremen1s of Chap1er 32 of 1he L·niform Build- ing Ccxk for shakes. In addi1ion, 1he deck shall be conmu.:1ed of· ,·1n.:h ply"ood "11h ex1enor glue or I-inch nominal T and G board,. merlaid "i1h a layer of ap- J)l'O\'ed asbcs1os fell lapped:! inches on the horizontal and ver1ical jom1s. An 18-in,h "ide s1rip of 1he same .isbes1os felt shall be shingled in be1wccn each .:oursc of shakes in SUl:h manner 1ha1 no fell is exposed 10 1he wea1her belo" 1he shale bum. (b) Wood Shini:le~. Spa:ial purpose wood shingle roofing ~hall .:onform 10 grading and appli,arion requiremenrs of Chapter 32 of 1he Uniform Building Code for shingks. In addi1ion 1he deck, whe1her of spaced boards or ,olid. shall be o,.:r- laid wi1h a layer of apprmed a,bcstos f.:11 lapped:! inches on 1he honzomal and ,.:r- 1ical join1s. tc) A~bnlo~ felt. Appru,cd a,b~10s fell for srt-.:ial purpo,c: ruoling ,hall "c1gh 001 le,-than I~ pound, p.:r 100 ~4uarc feel, be not k~s than .022 in,h III thi,~n.:,,. non-b11umirwu, ,a1ura1cd, .:0111a1nini; a fire-and \\a1cr-r,:1arda111 b1mkr. and re111- for.:cd "ith i;la,, fib.:r, runmng kngth" i,c of 1he ,hcct 1101 mor,: 1han ·• ind, a pan. Wood Shakes or Shingles with Gypsum Board Underlayment St-i-. 32.1402. Sp.:,1al purp,»e \\Ood ,hake or \Hlod ~hingk ru,1lin~ ,hall .:.1111,11111 10th,: !!radon!' and Jpph.:a11on re4uiremen1> ol l'hapt,:r 32 of the L no fo rm UuilJ1nt,: Code. In addnoon a11 und,·rl.1~111en1 of 1 :-in<·h T)pc :\ g)p,um boarJ ,hJII be plJ.:,:J w1Jer 1h.: ,ol1d or ,pJ,.:d ,h,·.11hini;. .. . . r 57A I ~I 75 p 011/0t= /80 5/+ow OM ..:-p ' ._;> - I ·~,-~ ~ ADDITIONAL REMARKS • l ,_:.. ," . ., 1 -.:f (,· o ;J IL (",,.,., 'r; ~7 1 I • ) :-: , {-i .:.' I ) . I ' I JI '../ _,:;- ' .. . ' ' , Date, ~I 1(1{~ ~ Jurisdiction C 4 P L 5 BA Q by1 VALUATION AND PLAN CHECK FEE 8 2,-JO / (A) BUILDING ADDRESS b ti c /E R, NA 6: A s· T. □ Bldg. Dept. t:1 t:::.S ~/L. APPLICANT/CONTACT PHONE NO. ----------------BUILDING OCCUPANCY R-3 (1,,,, I . 4 ) • DESIGNER PHONE ------TYPE OF CONSTRUCTION _v .... --~ ..... 1 ___ _ CONTRACTOR PHONE ----- BUILDING PORTION BUILDING AREA VALUATION VALUE ------L--- MULTIPLIER !_ I I ' (, 2-3 (.., 'L L/2,,-~o Lf Vl· (' :l I 5 ?,' b,~__, ~ ., ~~ r L. It/ I A., C, "2 'I,(_, 'l., -/42.-'7 ~. i~ '-/ Dt?Ck !~8'------i"' {,, -' 73, 8' -----~ lJ-7vl/-4-7 ,z_.-i--i,.,,ov f ' -II ~ 141/ ,-::; ~ (_ f-> j . ~v ~c-~ (< • " 1 I b ..... ,J) Air Conditionin,e: 1 ~~\C.-.,_ -.,, Commercial ~' /i) J _,,. -/'(/ Pf~ ' Residential r Fire Sprinklers - Total Value ~I - Building Fermit Fee l 8~~ %. {b Q Ott-Plan Check Fee -./ -C Qt{J,1 ENTS 1 --=---r _ .... , .... , __ ... _.___ __ '--____ ,_· •--, __ ,,_. ----.... ·--• -✓-'r_l_· __ t..,.• ~--• . __ ,,_ Date,-$/'{:..,.. Jurisdiction 1.. 1t· LS EAD PrepalJf by 1 ,-1 1) VALUATION AND PLAN CHECK FEE --......... ~----□ Bldg. Dept. P /=Scf IL PLAN CHECK NO. .;;_ ~ '">/ (E-) BUILDING ADDRESS ______ ...:.J_tl _( __ ! __ L_.1_1.._11...,l ...... , ...... C:"""'1 A_.__ ___ S __ J ..... ·-, ____ _ APPLICANT/CONTACT _________ PHONE NO. _______ _ BUILDING OCCUPANCY r JJ -I ---------DESIGNER PHONE ------TYPE OF CONSTRUCTION V --IY CONTRACTOR PHONE ----- BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER ,,/ G AUJ ,:;r-~51!.t .:" ,•.t ~ } //. -~ 't J O I -• V i=--, v / / V / / - Air Conditionin~ Commercial -- Residential Fire St,rinklers Total Value '-,~ Building Permit Fee A , - / b L/ I o.S- Plan Check Fee - COtl.MENTS, /', / .I / v11. , //, . , , . ,, ., ,.• I -. --t r .-,- ~" ,· A b ,: ' 7 r .-1 1 • • , c-z c APPLICANT PLAN WORKSHEET PCRMIT NUMBER ttz.,,-10 1 JOB ADDRESS '-"'' 11:T<N~gA -'t 1TY Cl41-1.-s elf-D ESTIMATED VALUATION OF WORK _______________ _ The value shall include all construction work for which the permit 1s issued as well as all fin1Sh work, painting, roofing, electrical, plumbing, heating, air conditioning, elevators, fire-extinguishing systems and any other permanent equipment, including contractors overhead and profit. BRIEF DESCRIPTION OF WORK D I,( f L a:x t p~~lhtl) ' ,9.~e,g:s BUILDING BUILDING OCCUPANCY OR USE 8, r 3 ,, M -/ TYPE OF CONSTRUCTION V .... N -----'----'------------- AREA _______________________ _ PLUMBING Plumbing Fixture Traps / l av./S1nk ................•................. tt!:t: .. tftf..u .... /-···· ........... _ .......... N,;'.:'r. ~:~;;~·~~=~·.·.·.:::·.:·.:·.:·.·.·.:·.·.:::·.:::·.·.·.·.:W.J.·.·.:·.:·.:·.:::·.::Z:·.:·.:·.·.·.:·.-.·.: ............... t. .. . Floor Drain/Sink ...........•.•••••..................•............... /··············-········ Clothes V.'asher Standp1pe ........ /.l. ..................... L. .................. -....... . 1- Grease Trap •....•................•..................•....•.•.......................••..•••........ Building Sewer ...•••.••..•..•....•.•......... /·············································-······· .•.••......... Water Heater/Storage Tanks •••..•... /. ....•...•........•.............................• -...••........ ;; ••.•. Gas Piping Outlets .....•.......•..•.••••...• ttt:/../.(l. ................................................. Y.. .... . Wa ter Piping Install or Repair ......•...•.............•..•....•.•.••..•....•..•..••.•••••..••.••....••.••••••.. Drain/Ve~t Install or Repair •••••.•.....•.........••••.. r······································ .............. . lawn Spr inkler System ....•.•..••••.••••.•••.•...•........•.......•.•........••......•..••••...•......... 1. ..... . Vacu;:seB::~:~.~·························tl/f J./... .................................. 1 ..... <e. ..... . Dishwasher ........................... 7/.:·.:·.:· ...................................... __ .......... l.. ...... . Other Fixtures or Equipment····················•·······························•·-····· .............. . Rain Water Drams Onterior) •..•...•.•.•••.•••••..••. /1. ........................................... ~ ...... . MECHANICAL Number Heating Units Forced Air Unn ....••.•...........•••......••••..•...•..•...• 1 ................................. ' 100,000 ATU or l ess ............................. L ......... : ............. ·-········ ..... k .. . Ov!'r 100,000 ATU ••.•••••••••....•.•...••••.........•..••.•••....••.••••••....•....••••....••••••.••.. Wal l Heater ....................................................................................... •·······•····· Suspended Heater •••.••••.•••..••••••••••••••.•••.••••.•••••••••••••••••••.••••••••.. ·-········ ••••.••••••••• Floor Mounted Heater ................................................. •··••·········-······· ............. . Floor Furnace •••••••••.••••••.••.•••..••••.•.•••••••..••.•••••.••••••••••••••••••.••.•••••••••.• Compressors, Heat Pumps, Industrial Boilers 3 H.P. or less/100,000 BTU or l ess ................................................. . Over 3 H.P .• J5 H.P./100,001-.500,000 BTU •••••••••.•••••••••••.••.••....•.•.....•. Over 15 H.P.-30 H.P./.500,001-1,000,000 BTU •••....•••••••.••.....•.....••........ 1·············· Over 30 H.P.-.50 H.P./J,000,001-1,7.50,000 BTU ••..•••••.•......•.•...•.•••......•.............. Over 50 H.P./ over 1,750,000 BTU ••••••.•.••••••••••••.••••••......•..•.•....••...•..........•..•... Air Handling Unit 10,000 CFM or less .......................•....................••...................•.......... over I O,OOOCF ,\1 ..•..............................•.•..... :.:J;J::J,;i.7 ........................... 1············ Vent Fan to a Single Duct. ...•.•.•....................... ~.!.lf..-................................... f:/! ..... . Hood IJ.'/Vent Fan, Jennaire, etc ••.........•.•........ // .•...•.........••....................... b .. . Other Vent1lat10n System Not Part of Heating or AC System ...••............................. Gas Piping Outlets .....•........•••.••....................................•.•.............••..•••.... , ...........•• Refrigeration I H.P = I Ton = 12,000 BTU's. ....•••..............•.•............••••......•...•••....... , ....•.•...••. Miscellaneous Install or Replace Appliance Vent Not Included in Appliance Permit Above ••.•..•••....•..••••.•••••••••.•••••••.•..•••••••••••••••••...••.•.••.•..•••••••••••. Repair, Alter, or Add to Heating Applaince, Refregeration Unit, Comfort Cooling Unit, Absorption Unit, or Evaporative Cooling Sustem, Including Installation of Controls ....•..••••••••••.•....•.....•...••.•.....•. Evaporative Cooler -Non-Portable Type ..........•.•.••..•••.........•.• : ..•.•••••..• , .......•..••. Other Applaince or Equipment Regulated by this Code, but Not otherwise Classified ..•••••••••..•.....•••.••....•.••........•••••••••••••••..........••..•.•..• 1 ••••••••••••• ELECTRICAL New Service Size in AMPS ........................................................................ 1 ... /..~~ ~ - Increase in Service Size in AMPS .•..........•.••••.•....•••••...••....••......••.•.....•..•.•. New Size _______ _ Old Size ________ _ Add or Revise Circuits (No Service Change) •••••••.•••••••••.••••..••..••••••.•...••••.•• Temporary Construction Power···-························•········•·········•······ .••••••••• \,: .. j , • lNIERDEPARTMEN I AL illEDRMAT I ON SHEE! E CE IVE D BUILDING DEPARTMENI DATE: ____ _ BUILDING ADDRESS: .,;)-S>-#:S'.3& ~""~ AUr, '1982 A.P.N: o?.tr-o£-£D -,2.-f c.T: kbf-"l;;..q-,,r_v OF CARLS-BAD -* * * i¼ * * * * * * t·.:l: * * * * :'· * * * t· *.li.:k]illi..fili.:tt ~ * * * * * m:rn:D...._ti * * * t4ii'trlJ.it &: f* ~* -i; * * * * PLANNING DEPARTMENT o2@ t~<rs<-f; • ZONE: SCHOOL FEES: SAN DIE GU ITO SAN MARcosl(.3) lo ~ ---------- ENCINITAS _____ CARLSBAD _____ _ ·UNITS REQ'D: PROVIDED: % COVERAGE A-LL_O_l-VE_D_:=============---·PROVID-ED-::::::::..:-0:~ ..... ~~:v--~---~-~-<---_-_-= PARKING SPACES REQ'D: PROVIDED: __ y-+----~~J--~-~--\-------- BUILDING HEIGHT REQ'D: _________ PROVIDED: ________ _ FRONT S:ETBACK ALLOWED: ±C: PROVIDED:_~,,e,-+--....,..... __ _ INTRUSIONS: ------ SIDE SETBACK REAR SETBACK RE-DEVELOPMENT APPROVAL REQ' D: --~N-~~---- LANDSCAPE & IRRIGATION PLAN COM~!ENTS :__._N..,__,_~.__ ___________ _ ENVIRON~mNTAL PROTECTION REQ = -~E~f~i;_m~«~------------- ADDITIONAL COMMENTS: sf:.-~.l>:::C-)..,t , t:tv;..± ~ ,(,<) Q. ~ '(\/\A • ,_ &<[\t\ a ~ OK TO ISSUE:~ OK TO FINAL: DATE: --------- PUBLIC FACILITIES FEE: SEWER CONNECTION: -------------- DRIV:EWAY LOCATION(S) =-----------~----__ _ GRADING PERMIT: ________________________ _ EASEMENTS: DRAINAGE: -----------------------LEGAL D!::SCRIPTION : _______________________ _ ADDITIONAL COMMENTS: ______________________ _ *CHECK IF ENGINE:ERING INSP:ECTION RJ:;Q'D. ON FINAL: _________ _ OK TO ISSUE:J)ltL DATE:$-S~L/ !'WI:~~~ OK TO FINAL: ____ _ llATE:____ · * IF Tl!IS ITEM IS NOT Cl!ECKED, BUILDJNG IJEl'AiffMl:NT WILL MAK:E FINAL INSPECTION. • "· •--s•-------~-... PHILIP HENl<ING BENlON PR[Srr>ENT ,·11/IL t:N<,l~f.E.R Mr. Herbert Co hen P.O. Box 923 BENTON ENGINEERING. INC. APPLIED SOIL MECHANICS -----FOUNDATIONS 5!'!40 RUFFIN ROAD SAN DIEGO, CALIFORNIA 921]3 August 16, 1982 Carlsbad, California 92008 Subject: Dear Mr. Cohen: Project No. 8 l-6-9M Moisture Contents in Subgrade Soils Lot 182 of La Costa Meadows U-.it No. 1 Carlsbad, California TELEPHONE ( 714) 5$5-105!5 This is to report the results of tests ta determine the moisture contents of the soils in the upper three feet below finished grade in the proposed building area at the subject site in Carlsbad, California. The soil samples were obtained on August 13, 1982 and the results of the moisture determinations ore presented as follows: Approximate Location of Samples Northeaster! y portion of proposed building area Southwesterly portion of proposed building area Depth Below Existing Grade in feet 1.0 2.0 3.0 1.0 2.0 3.0 Moisture Content (% dry wt) 18.4 25.7 22.2 20. 1 23.0 20.3 It is concluded from the field observations of the various soil types and the final results of the moisture determinations that the soils in the upper three feet below finished grade at the locations sampled have been sufficiently moistened to minimize the potential expansion of the soils, as recommended in our report under Project No. 70-10-28D dated October 12, 1971. It is recommended that positive drainage, 6 inches of vertical fall in 6 feet horizontally, should be provided around the perimeter of the house in landscaped areas. Drainage systems should also • Mr. Herbert Cohen Project No. 81-6-9M -2-August 16, I 982 be provided to collect oil runoff from roofs and conduct the water in watertight pipes either into the streets or storm drains, All surface drainage should be prevented from ponding adjacent to or running over the tops of slopes. Inlet boxes ond watertight pipes should be installed when necessary to comp I y with the above requirements. Respectfully submitted, BENTON ENGINEERING, INC. By ~·&e~~ Phil ip.ento[vil 7gfr,eer , RCE No, 10332 Distribution: (3) Addressee Pt-e/jr BENTON ENGINEERING, INC, ., - ' LEUCADIA COUNTY WATER DISTRICT APPLICATION FOR SEWER SERVICE Owner's Name Mr. & Mrs. Kasten G. Talmadge Phone No. 415-941-2158 Mailing Address 446 Guadalupe Drive ~>//y~os Altos, Ca, 94022 Service Addris~:7 Luciernaga Street Tract Description : _L_t_o_t_l_8_2_,_La_c_o_s_ta_M_e_a_do_w_s_,_u_n ,_· t_No. l SEWER PERMIT ISSUED UPON 11.r-::,_o;-o:: DUILDING PERMIT. tu:LJ,NG PERMIT MUST BE 02TA!NW BY -.,, -(j --_,. ::_;_c, Assessor's Parcel llo. 215-250-24 --''-'-"-=.;=--=--..:.----------j Type of Building ---=-du""p~l"'e,,,x ____ No. Units ___,,2'--_ Connection Fee $3,000.00 Lateral Size: 4" 6" 8" Saddle Easement Connection Extra Footage: @$ __ _ Amount Rec'd $]_,000.00 Ck. Mo/Cash 20::;5;,,....,...-- Date 3-23-81 Rec'd By ec"-'d=---- Extra Depth: ___ @ $ __ _ Lateral Fee Prorated Sewer Service Fee Total $3,000.00 The application must be signed by the owner (or his authorized representative) of the property to be served. The total charges must be paid to the District at the time the application is submitted. If a service latera.l is required, it will be installed by the Leucadia County Water District. The service lateral is that part of the sewer system that extends from ... the main collection line in the street (or easement) to the point in the street (at or near the applicant's property line) where the service lateral is connected to the applicant's building sewer. The applicant is responsible for the construction, at the applicant's expense, of the sewer pipeline (building sewer) from the appli- cant's plumbing to the point in the street (or easement) where a connection is made to the service lateral. The connection of the applicant's building sewer to the service lateral shall be ~ made by the applicant at his expense. The connection must be made in conformity with the District's specifications, rules and regulations; and IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT. THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC- TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND WILL NOT BE ACKNOWLEDGED. The prorated sewer service fee is based upon the date the District estimates that service will begin and covers the balance of the fiscal year. There will be no additional fee or refund if service actually conmences on a different date. For - succeeding fiscal years, the sewer service fee will be collected on the tax roll in the same manner as property taxes. The undersigned hereby agrees that the above information given is correct and agrees to the conp)tigns a;;-stat d. ;__ ,rt.,. q /'J1A..., . ~ C r. ? /J a.,?~ -23 Manh 1981 13722-23 wnersSignature Date Account No. ATI'ENTION PROPERI'Y OWNER: An "owr1<=.e-builder" building pennit has been applied for in your name and bearing your signa-qrre. Please ccmplete and return this infonnation in the envelope provided at your earliest opportunity to avoid unnecessary delay in processing and issuing your wilding permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) A/0 ; 2. I (have/have not) h <>-\J .e signed the application :Eor a building permit. 3. I have contracted with the following person (firm) to provide the proposed construction. Name Phone -------------------------- Address Contractors License No. ------------ City ------------- 4. I plan to provide portions of the w:irk, but I have hired the following person to coordinate, supervise and provide the major w:irk. Name -------------Phone -------------Address ------------Con tractors License No. ----- City ------------- 5. I will provide some of the work but I have contracted (hired) the following persons to provide the w:irk indicated: Name Address Phone Signed: Property OWner _u/[j=,,.___..J..._~~--'------------ Social Security Number :J.l t • 36· 3 d~ 7 ----~--~-------- Date: _~1 /_,. _1 )_c_2. ___________ _ Type of Work