Loading...
HomeMy WebLinkAbout2577 STATE ST; ; CB152713; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02-18-2016 Residential Permit Permit No: CB152713 Building Inspection Request Line (760) 602-2725 Job Address:2577 STATE ST CBAD Permit Type:RESDNTL Sub Type: CONDO Status: ISSUED Parcel No:2030543415 Lot #:15 Applied: 08/20/2015 Valuation:$295,759.00 Constuction Type: 5B Entered By: JMA Occupancy Group:Reference #: CT130005 Plan Approved: 02/18/2016 # Dwelling Units:1 Structure Type: MF5+Issued: 02/18/2016 Bedrooms:0 Bathrooms:0 Inspect Area: PY Orig PC #: PC140037 Plan Check #: PC150047 Project Title:STATE ST. TOWNHOMES: PHS 5 C1 405 SF 1ST FLR COMMERCIAL/1,694 SF LIV/ 476 SF GAR/ 67 SF BALCONY/ 585 SF ROOF DECK Applicant:Owner: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Permit $1,317.94 Meter Size FS1 Add.' Building Permit Fee $0.00 Add'I Recl. Water Con. Fee $0.00 Plan Check $922.56 Meter Fee $317.00 Add'I Plan Check Fee ($500.00)SDCWA Fee $4,800.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $38.45 PFF (3105540)$5,382.81 Park in Lieu Fee $6,190.00 PFF (4305540)$4,968.75 Park Fee $0.00 License Tax (3104193)$0.00 LFM Fee $0.00 License Tax (4304193)$0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541)$0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $210.00 Renewal Fee $0.00 ELECTRICAL TOTAL $89.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $65.38 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $3,931.00 Housing Credit Fee $0.00 Meter Size FS1 Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $3.00 Sewer Fee $881.00 Red. Water Con. Fee $0.00 Additional Fees $202.00 Green Bldg Stands (SB1473) Fee $12.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $28,830.89 Total Fees:$28,830.89 Total Payments to Date:$28,830.89 Balance Due:$0.00 jr FINAL APPROppttL Inspector:/I Date:3 .E 19)- 1 Clearance: NOTICE Please take approval of your coded indudes the "Inicositiok of fees dedications, reservations, or other exactions flu tefter collectively referred to as 'fees/exactions.'cc have 93 dayslionthe date this permit was isaked to est imposition of these fees/exactions.If you protest them, you must follow the protest procedures set forth in Government ilaie Section 66020(a), and file the and any other rvquired information with thetesty Manager for processing in accordance with Carlsbad Municipal Cali.Section 3.32.030.Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTI-ERNOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capaOty changes, nor planning, zoning, gracing or other sirrila-application processing or service fees in connection with tlis project.NOR DOES IT APPLY to any fees/exactions ofMich Youhaepreviously been given a NOTICE similar to this. or as to which the statute of limitations has Previously otherwise mired. •••••••„, , •••'k!'- .•PERMITINSPECTION HISTORY:REPORT (C131.02713).. Permit Type:BLDG-Residential Application Date:08/20/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status Closed -Finaled Expiration Date:09/01/2017 Address:2577 State St Carlsbad, CA 92008 IVR Number:708719 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 11/09/2016 11/09/2016 BLDG-15 000389-2016 Passed Paul York Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/21/2016 11/21/2016 BLDG-13 Shear 002038-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/28/2016 11/28/2016 BLDG-13 Shear 002922-2016 Failed Paul Burnette Reinspection Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/30/2016 11/30/2016 BLDG-13 Shear 003493-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/01/2016 12/01/2016 BLDG-13 Shear 003755-2016 Passed Paul York Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/22/2016 12/21/2016 BLDG-84 Rough 006459-2016 Passed Paul York Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 01/04/2017 01/04/2017 BLDG-17 Interior 008119-2017 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-23 008118-2017 Passed Paul York Complete Gas/Test/Repairs March 28, 2017 Page 1 of 2 •• PERMIT INSPECTION HISTORY REPORT (CB152713) Pi Diiit Type:BLDG-Residential Application Date:08/20/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status.Closed -Finaled Expiration Date:09/01/2017 Address:2577 State St Carlsbad, CA 92008 IVR Number:708719 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No 01/09/2017 01/09/2017 BLDG-18 Exterior 008800-2017 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/2312017 02/23/2017 BLDG-Electric Meter 014420-2017 Failed-Construction Paul York Reinspection Complete Release Change Needed Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/01/2017 02/28/2017 BLDG-Electric Meter 014842-2017 Passed Paul York Complete Release Checklist !tern COMMENTS Passed BLDG-Building Deficiency No 03/20/2017 BLDG-Fire Final 017243-2017 Scheduled Dominic Fieri Incomplete Checklist Item COMMENTS Passed FIRE-Building Final No 03/28/2017 03/28/2017 BLDG-Final 017923-2017 Passed Paul York Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes March 28, 2017 Page 2 of 2 Inspection List Permit#:CB152713 Type:RESDNTL CONDO STATE ST. TOWNHOMES: PHS 5 C1 405 SF 1ST FLR COMMERCIAL/1,694 SF L Date Inspection Item Inspector Act Comments 11/01/2016 17 Interior Lath/Drywall PY PA 10/27/2016 15 Roof/Reroof PD PA 10/11/2016 17 Interior Lath/Drywall PD PA 09/21/2016 17 Interior Lath/Drywall PY PA 08/29/2016 11 Ftg/Foundation/Piers PY AP 08/12/2016 21 Underground/Under Floor PY AP 08/11/2016 21 Underground/Under Floor PY AP 08/11/2016 22 Sewer/Water Service PY AP Wednesday, March 29, 2017 Page 1 of 1 sirCillalintato lltint [(.4::et tint[:Vetter/a tg% revlit IPSOumwE ............A. A. A.. Inspection & Testing,Inc.441 Commercial Way. La Habra. CA 90631 -6168 (56) 941 -2990 • (714) 526-8441 FAX 1562) 946-0026 December 12, 2016 Building Official City of Carlsbad Department of Building and Safety 1635 Faraday Ave Carlsbad, California 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name:Seagrove Townhomes Address:Tract #CT13-05,PH 5 Building 2 Owner:Taylor Morrison Lot#Address Permit Lot#Address Permit 10 2557 State Street CB152706 14 2573 State Street CB152712 11 2561 State Street CB152709 15 2577 State Street CB152713 12 2565 State Street CB152710 16 2581 State Street CB152714 13 2569 State Street CB152711 17 2585 State Street CB152707 This is to certify that Southwest Inspection and Testing, Inc. was employed to perform special inspection on the above mentioned project at the above address, which required continuous inspection per section 1701 of 2013 California Building Code. Brett Aiblinger -Reinforced Concrete, Post Tensioned Concrete, ICC #0881693 Bruce Gordon -Reinforced Concrete, Post Tensioned Concrete, ICC #1133732 Larry E Robertson -Reinforced Concrete, Post Tensioned Concrete, ICC #5090690 Based upon special inspection and materials testing written reports of this work, it is our judgment that the inspected work was performed to the best of our knowledge,in accordance with the approved plans, specifications and applicable workmanship provision of the California Building Code. ------. 00FE f -N, c/)414 C) - 7CA(47;0:112:4‘41.14 Sincerebi.Reviewed By:42<-'\-‘'y°0 ( (- . -'t '-i/,,. wcc\C.:J''E.''...\EXP 3...5/./ 7 r,Z)pr .S...........*' .\*\\R. :::CIV .*. Steven L.Go?ey Ian R.Waddell,P.E.Qf Ags.'._President Principal Engineer - SLG/IRW:amc For inspection and testing only. no design responsibility expressed or implied. 4\./.>CB152713 2577 STATE ST .CITY OF STATE ST. TOWNHOMES: PHS 5 C1CARLSBADINSPECTION RECORD 405 SF 1ST FLR COMMERCIAL/1,694 SF LIV/ 476 SFBuilding Division GAR/ 67 SF BALCONY/ 585 SF ROOF DECK INSPECTION RECORD CARD WITH APPROVED RESDNTL CONDO PLANS MUST BE KEPT ON THE JOB Lot#:15 TAYLOR MORRISON OF CA, LLC RI CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL:760-602-2725 REcoRD copy OR GO TO:.4. A..t •-•.•.f ••'....!..•AND CLICK ON "Reg ,sAt..on" DATE:.i If/ IF "Yt. S''Is CHECKED ITT.t OW THAT DIVISION'S APPROVAL IS REQUIRED t 'RE :R Tr.‘'t r.).-;I IN.A FINAL. BUILD/W.IN .PF CTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICAHL1 DIVISION'-;A I THE PHONE NUMBERS PROVIDED I i IOW.AFTER ALL REQUIRED APPROVALS ARE.SIC NFL-)OFF --FAX TO 760 602 8560 EMAIL. BRING IN A COPY OF THIS CARD TO.1635 FARADAY AVE.. CARLSBAD,CA 92008.BUILDING IN..I.E:(low.CAN PI_RFACIIED AT 760-602-2700 BETWEEN 7'30 AM --8:00 AM TI-IF DAY OF YOUR INSPECTION. NO YES Required Prior to Requesting Building Final If Checked YES Date Inspector Notesy-Planning/Landscape 760-944-8463 Allow 48 hours 3 •VI. t1 rvi.- SS/ -cm6.1 (Engineering Inspections)760-438-3891 Call before 2 pm `17111 ZZeit')(Fire Prevention 760-602-4660 Allow 48 hours 3p-31 Type of Inspection •of Inspection CODE tt BUILDING Illar 111111==.1 cow:1.*ELECTRICAL Date Inspector #11 FOUNDATION %VI toitc 'Or.#31 0 ELECTRIC UNDERGROUND 0 UFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC.. #66 MASONRY PRE GROUT #33 0 ELECTRIC SERVICE 0 TEMPORARY 0 GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS CODE #MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPING #14 SUBFRAME 0 FLOOR 0 CEILING •#44 0 DUCT&PLENUM 0 REF. PIPING #15 ROOF SHEATHING Pho I *#43 HEAT-AIR COND. SYSTEMS - #13 EXT. SHEAR PANELS ..4 .:*.ii..e..#49 FINAL #16 INSULATION Cool 0 COMBO INSPECTION #18 EXTERIOR LATH 1 /17 #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH &DRYWALL j g Ai 7 ,'#82 DRYWALL,EXT LATH. GAS TES (17,18,23) #51 POOL EXCA/STEEL/BOND/FENCE #83 ROOFSKATING,EXT SHEAR (13,15) #55 PREPLASTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44)1-2-/.2 j iikep iii..e.'#19 FINAL #85 T-Bar (14,24,34,44) CODE tt PLUMBING Date Ins .tor #89 FINAL OCCUPANCY (19,29,39,49) #22 0 SEWER & BL/CO 0 P1,/C0 juilliprIAMIll F 1 R E Date Ins •-or #21 UNDERGROUND OWASTE 0 %VTR ob -0 #24 TOP OUT 0 WASTE 0 wit A/S UNDERGROUND VISUAL #27 TUB &SHOWER PAN A/S UNDERGROUND HYDRO #23 )11(GASTEST 0 GAS PIPING iblija7 n A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL V11.1:7..#28 SOLAR WATER A/S OVERHEAD HYDROSTATIC I ItIlL laoirt #29 FINAL A/S FINAL 3 \'‘\).-7\44\ CODE 11 STORM WATER F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL .%%•114-41.1'" #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN 305 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV 10/2012 SEE BACK FOR SPECIAL NOTES Development Services(City of CIRCUIT CARD Building Division Carlsbad B -36 •.1635 Faraday Avenue ' . 760-602-2719 www.carlsbadca.gov THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION Address:/Ls-11 %OA/c)t-ulik"Permit Number: Owner:Phone:Area in Sq. Ft. Contractor:Phone: PANEL:A.LC.1 142 VOLTS 2 yo 0 po WIRE BKR WIRE r WIRE BKRLOCATIONCKTMISCRECRECLTGMISC CKT LOCATIONSIZESIZETYPESIZETYPESIZE Spit.Pec.1 t S -(J kwp t _ t1 'clk(A 0 i 5-2 Ft Iry lull i3u 3 3 IS- -"C\"j 3 tlA ;e.;--4 ...-i...1.1.e- (..(ut...3 te.5 l C.- ((A 1 c‘Co 1 vt. t51-P.7 (((Gi '-\-1.. 1 11.7A'to 86 - 4Bt 4.-tc5:::( P(8.4-9 .('j tut Lc to %(- 1-`7...0 10 VC._ ,1001ACii6HA 11 (S.'I IA 1.-q 1 t1 j.0 12 C kii/6.44, L 13 (S 0A 11-9 1 I ,10 14 A/C,PI3/5K. 6 15 t (45- --ka ko (9 ‘(0 ts---- 16 Ax_ Lk i18 Dit.ii'ti17-i.e4 ii-\/ 1 i C/- Km4k0/1- 44/ „i S 0.119 )-20 *1014. 21 22 23 24 .. 25 26 27 28 29 30 31 32 33 34_. 35 36 37 38 39 1 40 ., 41 .42 MAIN:0 $e)0 AMP BRK/FUSE 0 MLO Computed Load AMPS BUS:AMP See Calculation Worksheet on back Service entrance or feederponductors:Branch circuits required: A) Lighting Circuits 220 -3(b), 4(d)A) Size: No.ye B) Type:0 CU 0 AL B) Two Small Appliance Circuits 210 -11(e) C) Insulation:D) Conduit Size:C) Laundry Circuit 220 -16(b) Service ground/bond:D) Central Heating Equipment 422 -12 A) Size: No.VO B) Type:EirCU CI AL E) Bathroom 210 -52(d) ,C)Clamp location(s): L UFER 250 -50(c)Remarks:0 Water Pipe 250 -104 0 Ground Rod 250 -52a GFCI locations 210 -8,680 -70:I certify that all terminations have been torqued in accordance with manufacturer's `CI Bathroom(s)10 Kitchen instructions and that the work shown on this circuit card represents the full extent of -0 Garage(s)0Hydromassage Tub the work performed under this permit. •1:3 Outdoors 0 a Owner &CI Protected Circ. 210 -12 0 Contractor (e.--lei .--03 Bedroom(s)0 Signed c-.--Date / t -ly -W. -..• B-36 Page 1 of 2 Rev. 03/09 SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an alternative method, the STANDARD METHOD found in ARTICLE 220 of the National Electric Code, may be used 1.GENERAL LIGHTING LOADS Dwelling sq. ft. x 3 VA =220-3(a)VA , Small appliance loads —220-16(a) 1500 VA x circuits =VA Laundry load —220-16(b) 1500 VA x circuits ='VA • General Lighting Total VA 2.COOKING EQUIPMENT LOADS -Nameplate Value Range VA =VA Cooktop VA =VA Oven (s)VA =VA Cooking Equipment Total VA 3.ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA =Dryer Total VA 4.FIXED APPLIANCE LOADS 230-30 (b) (3) Dishwasher =VA Disposal =VA Compactor =VA Water Heater =VA Hydromassage Bathtub =VA Microwave Oven =VA Built-in Vacuum =VA VA Fixed Appliance Total VA 5.OPTIONAL SUBTOTAL (Add all of the above totals)VA • 6.APPLYING DEMAND FACTORS -TABLE 220-30 First 10,000 VA x 100% =10,000 VA Optional Subtotal (from line 5) { Remaining VA x 40%=VA 7.HEATING OR AC LOAD —TABLE 220-30 Larger of the Heating or AC Load =VA 8.OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7)=VA 9.MINIMUM SERVICE SIZE =Optional Loads Total =Ampere 240 Volt (Please put total on front of card under Computed Load) BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 1 of 3) Site Address:Enforcement Agency:Permit Number: LOT 1 5111101'STAVE STREET.CB152713 Ifmore than one person has responsibilityfor installation ofthe items on this certificate, each person shall prepare and sign a certificate applicable to the portion ofconstructionforwhich they are responsible; alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificatefor the entire construction.Allapplicable Mandatory Measures with check boxes require to be checked to ensure the mandatory measures have been met. Description of Insulation I.RAISED FLOOR Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): §150(d):Minimum R-I3 insulation in raised wood-frame floor or equivalent U-factor. 2.SLAB FLOOR/PERIMETER Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): Perimeter Insulation Depth (inches): O §150(1): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. 3.EXTERIOR WALL a.Insulation Type (e.x. Batt, Loose Fill, Spray Foam) 2X4 BATTS a.Thermal Resistance (R-Value):R-13 b..Insulation Type (e.x. Batt, Loose Fill, Spray Foam) 2X6 BATTS b.Thermal Resistance (R-Value):R-19 Brand:MANVILLE Spray/Loose fill)Installed Actual Thickness Spray/Loose fill) (inches):Contractor's min installed weight/ft2 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) §150(c):Minimum R-13 insulation in wood-frame wall or equivalent U-factor. Exterior Foam Sheathing (rigid Insulation) Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 4.FOUNDATION WALL Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 5.CEILING Batt or Blanket Type:BATTS Brand Name:MANVILLE Loose Fill Type:Thermal Resistance (R-Value):R-30 Spray Foam Type:Brand Name: Installed Actual Thickness (inches):Contractor's min installed weight/ft2 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value):0 §150(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 6.ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material:Brand Name: Material:N/A Brand Name: Thickness (inches):Thermal Resistance (R-Value): O §118(a):Insulation installed meets Standards for Insulating Material. §150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16. 2008 Residential Compliance Forms August 2009 RI DG 9 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 2 of3) Site Address:Enforcement Agency:Permit Number: LOT 15-2577 STATE STREET CB152713 Description of Roofing Products CRRC Product ID Manufacturer Product Roof Roof Product Initial Solar Aged Solar Thermal Number'Information Brand/Model Type Area Slope Weight rReflectance Reflectance'Emittance 0' 1:13 I.The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at ww.coolroofsorg/products/search.php 2.The weight in lbs per square feet ofthe roofing product being installed 3 Check box ifthe Aged Reflectance is a calculated value using the equation below, footnote 4. 4.Ifthe aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the directory and use the equation (0.2+ 0.7(pounal -0.2) to obtain a calculated aged value. CCHECK APPLICABLE BOX BELOW IFEXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENT: O The roofarea covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from the above Cool Roof criteria. O Roof constructions that have thermal mass over the roof membrane with a weight ofat least 25 lb/ftl is exempted from the above Cool Roof criteria. To apply Liquid Field Applied Coatings, the coating must be applied with a minimum dry mil thickness of20 mils across the entire roofsurface and meet minimum performance requirements listed in §1l8(.)3 and Table I18-C.Select the applicable coating 0 Aluminum-Pigmented Asphalt Roof Coating 1 Cement-Based Roof Coating I 0 Other 1 0 CRRC-1 Label Attached to CF-6R (Note ifno CRRC-1 label is available, this compliance method cannot be used and another method is required to meet compliance). FENESTRATION/GLAZING Product #Total Quantity Add. Exterior comments/ Manufacturer/Brand Name U-Product of NFRC of Like Product Area Shading Dm Location/ Special Item (GROUP LIKE RODUCTS)factor'_SHGC',Panes Certified"(Optional)ft2 or Overhang Features 2 3 4 N/A 5 6 7. 8. I.Use valuesfrom afenestration product's NFRC Certified Label. For fenestration products without an NFRC label,use the default values from Section 116.Table 116-A and I 16-B ofthe 2008 Energy Efficiency Standards. 2.NFRC Label Certificates shall not be removed until the building inspector has verified the efficiency. Enter Yes or No. O §116(a)I: Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. O §116(a)2 and 3: Actual fenestration products installed are equivalent to or have a lower U-factor and/or a lower SHGC than that specified on the Certificate ofCompliance (Form CF-1R). 0 § I 16(2)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a) §117:Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed. 2008 Residential Compliance Forms August 2009 BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 3 of 3) Site Address:Enforcement Agency:Permit Number: LOT 15-2577 STATE STREET CB152713 DECLARATION STATEMENT •I certify under penalty ofperjury, under the laws of the State of California, the information provided on this form is true and correct. •I am eligible under Division 3 ofthe Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). •I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. •I reviewed a copy of the Certificate ofCompliance (CF-I R) form approved by the enforcement agency that identifies the specific requirements for the installation.I certify that the requirements detailed on the CF-IR that apply to the installation have been met. •I will ensure that a completed, signed copy ofthis Installation Certificate shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections.I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name:(Installing Subcontractor or General Contractor or Builder/Owner) ROCKWELL DRYWALL, INC. Responsible Person's Name:Responsible Person's it3.atu;. BUTCH INGRAM CSLB License:Date Signed:Position With Comp.•y itl 14R 956154 1/10/2017 VP OF OPERATIONS 2008 Residential Compliance Forms August 2009