HomeMy WebLinkAbout2604 EL CAMINO REAL; A; CB961074; Permit*
1 • *
B U I .L D I N G, P ER M I T Perthit No: CB961074'
08/19/96 14:54 Project No:A9601535
Page. 1 of 1 Development.No:
JobAddtess: 2604 L CAMINO REAL Suite:'A
.Pernit' Type.: COMMERCIALTENANT IMPROVEMENT 9171 08/19/96 000101 02,
Parcel No: Lot#: C'PRMT 1337i00
Valuation 88,200 Construction Type:,VN.
Occupancy Group Reference#:' J Status: ISSUED
Description: 2450 SF TENANT IMPROVEMENT Applied: Q6/14/96
RUBIOS FISH TACO Apr/Isue: 08/19/96
Entered By: MOP.
Appl/Ownr :•KERR, BILL 619 273-4649
4655.CASS STREET 4ff200 *
SAN DIEGO,, CA*. 92109
*** Fees Requir,ed Feesilected & Credits
Idjustments: / To ((Ci?it\: .00
Total Fees -
al 13371 00
Fee description Units U 't Ext fee, Data, -------------------
Building Permit •••.•.. ••.• 590.00
Plan Check' 384.00
Strong Motion Fee 19.00'
'Enter Traffic. Imp ct Fee 1
*'BUfLDING TOTAL 13471.00
Enter or Plum ing Is u Fe, 201.00 Y.*
Each Plumbing Fixt re or Tap )/ 14 7. 0 98:00
Each.-,Install/Repair Wate.inJ NORPORATED 7. 0 7001
Ea'ch'Watei Heater an /ot(Wnt > 1952 b 7.00 •7.00
Gas Piping System 4 .00 f4.00
*. LUMBING:TOTAL // fl - .• 146.00
-Enter "Y t for Electric I ue'..'/ 0 10.00 Y
Remodel/Alter Per AMP U> 30 • 25 * 7500
* ELECTRICAL TOTAL . . . 85.00
Enter 'Y'. forMechariical Issue Fee> 45.00Y
Install Fürn/Ducts/Heat Pumps > . .. 2 9.00 'n. o0
Each Exhaust Fan • • > 1 6,50 - • 6.50
Each Hood > .. 2 6.50 .13.00
* MECHANICAL TOTAL . - . 53.-00 - - • *
PER1I1T APPUCATION (.1 City of Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 .
I. PERMIT TYPE
PLAN CHECK NO.
ESTVAL
PLAN CK DEPOSIT _zs
VALID. BY / ,v-tPV
From List I (see back) give code of Permit-Type:
---------------------------------------------------------
For Residential Projects Only: From List 2 (see back) give
Code of Structure-Type:
Net Loss/Gain of Dwelling Units 8053 06/14/96 0001 01 02 I C-PRIIT 384 .00
2. PROJECT INFORMATION FOR OFFICE USE ONLY
Address Building or Suite No.
Nearest Cross Street a6oy A et aru toto 4e-& /
CHECK BELOW IF SUBMITTED:
fl2 Energy Calcs 02 Structural Calcs 02 Soils Report DI Addressed Envelope
ASSESSOR'S PARCEL EXISTING USE pnnpncn iici
DESCRIPTION OF WORK
SQ. F. '6 (J # OF STORIES - # OF BEDROOMS # OF BATHROOMS
NAME (lastname first) K lacr, ADDRESS Cc&ss .ç. 51-
%'.e-CITY STATE ZIP CODE . DAY TELEPHONE ((a 2 -13 '( '
4. APPUCANI' U ON1 (IUR U AL EN I 1Th{ CONIRACIUI1 DOWNER AGENT FOI OWNEI NAME (last name first) ADDRESS '40s5 CGS Si4ce: .00
CITY tj STATE ('A ZIPCODE 'Tolk oq DAYTELEPHONE(t' I-'((,
. t'1tutrAiiYuwNLK 'J
NAME (last name first) Wc&.<e& 4' ADDRESS A)1 Sc4& Qko Ave. Le 41
CITY STATE QA ZIP CODE DAY TELEPHONE (g 51' — '7 ((3 6. (DNTRAC'FOR
NAME (last name first) 1-i3 EO )I3 . RESS 3 3o C'JE -oLLoL,.)
CITY L\'J+ 'A STATE ZIP CODE 2 d- DAY TELEPHONE (C. 43(_-1,6P0
STATE LIC. LiCENSE CLASS __ CITY BUSINESS LIC. #
DESIGNER NAME (last name first) ç ADDRESS Qu- (4 \J
CITY Sc,..v',. C)' STATEçA ZIP CODE I. L(. DAY TELEPHONE 51-.qso STATE LIC. # C 1113 O
- 7. WORKERS' COMPENA*FTON
Workers' Compensation Declaration: I hereby attirm that I have a ceruticate ol consent to sell-insure issued by the Director of Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. Q.
INSURANCE COMPANY 5Ttç - j ij - POLICY NO. Q742(DZ EXPIRATION DATE 3.-ol.- 17
%-ClLJlMdLUUll1AU111PLJVll. I cetuty uiat in we pertormarice 01 we work tor wnicn mis permit is issued, i snail not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California.
SIGNATURE DATE
8. OWNER-BUILI)ER DECLARA11ON
Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractors License Law !or the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law).
1 am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
DYES ONO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
DYES 0 N
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
DYES ONO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLU11ON CONTROL DISTRICT.
WNSTRUCI1ON LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
APPUCANI CE911IICNflON
I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS
AND EXPENSES WHICH MAY IN ANY WAY A(XIRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA An OSHA permit is required for excavations over 5'O" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or aband ned at any ti e afer the work is commenced fora period of 180 days (Section 303(d) Uniform BuilcJinCod.
APPLICANTS SIGNATURE DATE:
-O?LoJ
SEWER PERMIT
08/19/96 15:04 ,Permit No: SE960092,
Page 1 of. :i Bldg PlanCk#: '.
Job Address 2604 EL CANINO REAL Suite A
Permit Type SEWER - RESTAURANTS 9170 08/19/96 0001 01 02
Parcel No CPFMT 1196 (st)'
Description: 2450 SF TENANT IMPROVEMENT Status: .ISSUED.
'RUBIOS FISH TACO - Applied: 08/05/96:
-Apr/Issue: '08/19/96
Permitee KERR, BILL 619 273-4649 Expired
655 CASS .STREET #200 - PreparedBy: MDP
SAN DIEGO, CA. 92109
*** Fees Required Fesllected & Credits
- Fe's: 11,39j0 -
Adjustments:
* / .0' &tE/fredit¼s: .00
Total Fees: 11/396.0 Totaçit\: 1.00
/ ç\ he\ 11,396.00
Fee description / £L. / kUhit /U it Ext fee -Data
BaseEDUs for All /Re,st h. - - 2.67
Enter Sit Down-Fast Pe>d, el Cap. - 6
Fast Food, Deli D" 5.00
<Enters CREDIT ED
> 1: ' -
Sewer Fee . - 11396.00
Ehter Sewer EDUs a d Bene iAr 6. 00
* SEWER TOTAL - 11396:0O: --
INCORPORATED
1952
( /
CITY OF CARLSBAD
- . . 2075 Las, Palmas Dr., Carlsbad, -CA 92009 (619) 438-1161
4- .. .
lO'll/96 INSPECTION HISTORY LISTING
FOR PERMIT# CB961074
DATE INSPECTION TYPE INSP ACT COMMENTS
11/11/96 Final Combo RI RI
10/11/96 Final Combo TP AP
10/08/96 Rough Combo RI RI
10/08/96 Rough Combo TP WC
10/08/96 Final Combo TP P1
09/30/96 Frame/Steel/Bolting/Wel TP AP
09/30/96 Rough Electric TP AP
09/30/96 Rough/Ducts/Dampers TP AP
09/30/96 Rough/Ducts/Dampers TP AP
09/27/96 Frame/Steel/Bolting/Wel TP P1
09/27/96 Rough/Topout TP P1
09/27/96 Rough Electric TP P.1
09/27/96 Rough/Ducts/Dampers TP CO
09/27/96 Rough Combo RI RI
09/19/96 Gas/Test/Repairs RI RI
09/19/96 Gas/Test/Repairs' PY AP
09/09/96 Interior Lath/Drywall RI RI
09/09/96 Interior Lath/Drywall TP AP
09/09/96 Rough/Ducts/Dampers RI RI
09/09/96 Rough/Ducts/Dampers TP AP
09/04/96 Frame/Steel/Bolting/Wel TP AP
09/04/96 Franie/Stéel/Bolting/Wel TP AP
09/04/96 Interior Lath/Drywall TP AP
09/04/96 Gas/Test/Repairs TP 'AP
09/04/96 Rough/Topout TP . AP
09/04/96 Rough Electric , TP AP
09/04/96 Rough/Ducts/Dampers TP WC
09/04/96 Rough Combo RI RI
08/21/96 Underground/Under Floor RI RI
08/21/96 Underground/Under Floor TP AP
MW/LARRY/434-4673
GAS RELEASE FOR FIRE TEST
T-BAR GRID
CEILING LITES
DUCTS -
METAL AROUND HOOD DUCT COLLAR
A/B REV DUCTS REQ
BJN/434-4673
MW/JOE/434-4673
RS/434-4673
RS/434-4673
GREASE SHAFT DUCT
WALLS
GREASE SHAFT ENCL
GREASE SHAFT ENCL
GAS. TEST/LINE INSIDE TI
WALLS
RS
MW/JOE
ND A/B FOR LAYOUT
HIT <RETURN> TO CONTINUE...
-l Aft --ruction
Environmental
Geotechnical
Consulting • Engineering • Testing
INSPECTION REPORT
PageJ_...of..
CLI ENZ7rry &4kn 4
DATE
Architect
Engineer z i/t'c 6Jiie
Contractor 7T Lcti-y -
PROJECT (Name)
(Address)2 '4E1_Cctrni'ro
&
REPORT NO.
Building Permit No.
Plan File No.
Govt. Contract No.
OSA or OSHPD #____________________________
Other
INSPECTION
_OSHPD
_OSA
.__Specialty
_Mechanical
_Electncal
_Roofing
MAIL SAMPLING QTY
_Concrete Cylinders _____
_Cement
Mortar Samples
_Grout Samples
.__Masonry Prisms _____
_Masonry Block _____
MATERIAL DESCRIPTION
- Rinf.: Rebar
- Rinf.: W.W.F.
- Rinf.: Tendons
- Conc.: Mix #/psi
- Conc.: Mix #/psi
- Conc.: Mix #/psi
INSPECTION CHECKLIST
- Plan & Specs
- Clearances
- Positions___________________
- Sizes
- Laps______________________
- Future Continuity #/psi
Concrete Fireproofing - Grout: Mix #/psi - Consolidation________________
_Masonry .__Units (block or brick) _____ Mortar: Type/psi - Mortar Batching
..__Struct Steel _Asphalt Concrete ._Units: Block - Electrode Storage
- Prestress Conc -Roofing - Units: Brick - Torque Applied
_Pile Driving _.__Reinf. Steel Steel - c -
- H.S. Bolts _.....Fireproofing _Steel 6 ' __Waterproofing —H.S. Bolts Metal Decking
Non-Destructive Tendon (PT Strands) - Electrodes___________________
_Soils Technician _Other Fireproofing
_74ch P1 t _Other _.± Other 44 ,( —Corrective action required
ol PulI-Ou Other fair - Corrections completed
REMARKS.
CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reported work, unless otherwise noted, substantially complies with approved plans,
specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin-
ion or project control. 10-1-1
INSPECTOR NAME
INSPECTOR SIGNA
PSI-8-900-170(1)
CERT. NO.
DATE
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING RE). PLANNING U/M .WATER
PLAN CHECK#: CB961074 DATE: 10/10/96
PERNIT#: CB961074 PERMIT TYPE: CTI
PROJECT NAME: 2450 SF TENANT IMPROVEMENT
C ADDRESS:'/
J fl OCT 13
CONTACT PERSON/PHONE#: MW/LARRY/434-4673 U L SEWER DIST: WATER DIST:
INSPECTED DATE j 7 7- BY: u". _A INSPECTED: APPROVED DISAPPROVED -
INSPECTED - DATE
BY: INSPECTED: APPROVED DISAPPROVED -
INSPECTED DATE -
BY: INSPECTED: APPROVED DISAPPROVED -
COMMENTS:
S
/
EsGil Corporation
Trofessiona(Plan Review Engineers
DATE: 8/2/96
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-1074
PROJECT ADDRESS: 2604-A El Camino Real
PROJECT NAME: Rubio's TI
SET: III
O APPLICANT
ci FIRE
'UiN REVIEWER
0 FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
Lii The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Bill Kerr's staff.
Date contacted: 8/2/96 (by: ga) Telephone #: Walk-in
REMARKS: City Building Department to review Health Department approval.
By: Kurt Culver Enclosures:
Esgil Corporation
LII GA [J CM 0 EJ 0 GP ] PC 8/2/96 . trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576
ESGII Corporation
Professional P&zn Review Engineers
DATE: July 23, 1996
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-1074
PROJECT ADDRESS: 2604-A El Camino Real
U APPLICANT
U FIRE
AN REVIEWER
U FILE
SET: II
PROJECT NAME: Rubio's TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's **********• codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Bill Kerr 4655 Cass St., Suite 200 San Diego 92109
cc: Schuss& Clark 9474 Kearny Villa Road, #215 San Diego 92126
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: ) Telephone #:
REMARKS:
By: Kurt Culver Enclosures:
Esgil Corporation
GA D CM 0 EJ fl GP U PC 7/16/96 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576
Carlsbad 96-1074 II
July 23, 1996
RECHECK PLAN CORRECTION LIST
JURISDICTION: Carlsbad PLAN CHECK NO.: 96-1074
PROJECT ADDRESS: 2604-A El Camino Real SET: II
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED:
ESGIL CORPORATION: 7/16/96 July 23, 1996
REVIEWED BY: Kurt Culver
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with .the cited codes and regulations. Per- Sec. 106.4.3,,
1994 Uniform Building Code, the approval of the plans. does not permit the violation of any
state, county or city law.
Please make all corrections on the original tracings and submit two new sets of prints to:
ESGIL CORPORATION.
To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. Please contact me if you have any
questions regarding these items.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
UYes No
Carlsbad 964074 II
July 23, 1996
PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
JURISDICTION: Carlsbad DATE: 7/23/96
PLAN REVIEW NUMBER: 96-1074 SET: II
PLAN REVIEWER: Glen Adarnek
9. Provide evidence of Health Department approval (for restaurants).
PLUMBING (1994 UNIFORM PLUMBING CODE)
15. Correct detail 5 on sheet D2 to show the required two straps on the water
heater. One strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank.
UPC, Section 510.0
. MECHANICAL (1994 UNIFORM MECHANICAL CODE)
17. The 18 x 20 inch grease duct, from the kitchen hood, with the required 3 inch
clearance from the fire rated grease duct enclosure and the 5/8 type X drywall of
the fire rated grease duct enclosure, will not fit between the 2 x 4's at 24 inches
on center as shown on sheet SI. Please correct maximum 15 inch wide duct will
fit between the 2 x 4's at 24 inches on center with required clearances. Please
correct.
. ENERGY CONSERVATION
20. The standard time switch will not comply with the exterior lighting control
requirements. Please correct. "Exterior, lighting controlled from a lighting panel
within the building shall be controlled by a directional photocell or
astronomical time switch that automatically turns off exterior lighting when
daylight is available."
Note: If you have any questions regarding this plan review list please contact
Glen Adamek at (619) 560-1468. To speed the review process, note on this list
(or a copy) where the corrected items have been addressed on the, plans.
EsGil Corporation
Trofessiona[fP&zn Review Engineers
DATE: June 27, 1996
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-1074
PROJECT ADDRESS: 2604-A El Camino Real
PROJECT NAME: Rubio's TI
SET: I
U CANT
JURIS. U FIRE
U AN REVIEWER
U FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
The plans transmitted herewith will substantially comply with the jurisdiction's ********** codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Bill Kerr 4655 Cass St., Suite 200
San Diego 92109
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: ) Telephone #:
LI REMARKS:
By: Kurt Culver Enclosures:
Esgil Corporation
GA 0 CM 0 EJ fl GP D PC 6/17/96 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax(619)560-1576
Carlsbad 96-1074
June 27, 1996
M
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 96-1074
IOCCUPANCY: A3
TYPE OF CONSTRUCTION: V-N
IALLOWABLE FLOOR AREA: to be
determined
SPRINKLERS?: ?
REMARKS:
JURISDICTION: Carlsbad
USE: Restaurant
ACTUAL AREA: TI=-2450
STORIES: n/c
HEIGHT: n/c
OCCUPANT LOAD: -62
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
JURISDICTION: ESGIL CORPORATION: 6/17/96
DATE INITIAL PLAN REVIEW PLAN REVIEWER: Kurt Culver
COMPLETED: June 27, 1996
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1994 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994U8C) tiforw.dot
Carlsbad 96-1074
June 27, 1996
1. Please make all corrections on the original tracings and submit two new sets of
prints, to:
Esgil Corporation, 9320 Chesapeake Drive.,Suite #208, San Diego, CA 92123,
(619) 560-1468.
2. Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes. Business and
Professions Code.
3. When the character of the occupancy or use changes within a building, the
building must be made to comply with current Building Code requirements for the
new occupancy. Please provide complete details to show the building will
comply. Section 3405.
Provide an analysis on the plans, showing that the TOTAL building floor
area does not exceed the Code allowable.
Show an assumed property line between this building and Building 1.
Due to the new A3 occupancy, additional fire protection may be required.
4. Exit doors from Group A occupancies shall not be provided with a latch or lock
unless it is panic hardware. Chapter 10.
The notes for hardware type 3 are confusing. Please revise it to clearly
state that panic hardware is required.
The door schedule states that door Al isn't used, but it's the main entry!
5. Provide structural justification to place new loads on the roof framing, as shown
on sheet A6.
6. See below for P/M/En corrections.
7. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
8. Please indicate here if any changes have been made to the plans that .are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction
list? Please indicate:
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
619/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Kurt Culver at
Esgil. Corporation. Thank you.
Carlsbad 96-1074
June 27, 1996
9. Provide evidence of Health Department approval (for restaurants).
PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
PLAN REVIEWER: Glen Adamek
. PLUMBING (1994 UNIFORM PLUMBING CODE)
Correct the water line sizing calculations. The American Standard #2168.128
Elderly New Cadet Aquameter water closet requires 20 psi minimum to operate.
Not the 15 psi used in the water line sizing calculations.
Provide gas line plans and calculations, showing pipe lengths and gas demands.
UPC Section 1217.0
The mop sink, floor drains in the kitchen, and two compartment sinks (Item # 15)
must drain through the grease interceptor or grease trap. Please correct. UPC,
Sections 1011.0 or 1008.0
Show the required relief vent for grease interceptor. UPC, Section 1008.4.
No vent from an indirect waste piping shall combine with any sewer connected
vent, but shall extend separately to the outside air. Correct the lavatory vents.
UPC Section 803.0
Correct detail 5 on sheet D2 to show the required two straps on the water heater.
One strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank. UPC,
Section 510.0
MECHANICAL (1994 UNIFORM MECHANICAL CODE)
Show the location of the required access ladder to roof mounted HVAC
equipment. UMC, Section 321.8
Provide complete kitchen hood plans, details, and calculations to show
compliance with UMC, Chapter 5, Part II as per the following:
Provide roof framing around new openings in the roof for the exhaust and
make-up air ducts for kitchen hoods.
Each room provided with a kitchen exhaust system shall have air supplied
to the room equal to the amount of air to be exhausted. The exhaust and
make-up air systems shall be connected by an electrical interlocking
switch. UMC, Section 402.'4
The fire-rated grease duct and/or hood enclosures must extend from the
point of penetration of the ceiling up to the roofing. The ceiling or hood
Carlsbad 964074
June 27, 1996
enclosure must be over the hood. UMC, Sections 507.6, 508.4, and
508.4.1
The fire-rated grease duct enclosures must be sealed around the duct at
the point of penetration of the ceiling. UMC, Section 507.6
Clearly show the material used to construct the hood and exhaust duct.
UMC, Sections 508.2 & 507.3
f) A complete kitchen hood system plan review will be done when complete
hood system plans, details, and calculations are provided.
. ENERGY CONSERVATION
Provide complete energy designs for the proposed changes in envelope.
Provide the completed ENV- forms showing envelope energy compliance.
On the plans clearly show the wall and roof insulation locations, thickness, and
R-values, as per the energy design.
Detail required exterior lighting controls. "Exterior lighting controlled from a
lighting panel within the building shall be controlled by a directional photocell or
astronomical time switch that automatically turns off exterior lighting when
daylight is available."
Correct the daylit areas and required daylit area lighting controls for lighting in
daylit areas for the window on the west side of the building. Title 24, Part 6,
Section 131(c).
22. The completed and signed ENV-1 forms must be imprinted on the plans.
Note: If you have any questions regarding this plan review list please contact
Glen Adamek at (619) 560-1468. To speed the review process, note on this list
(or a copy) where the corrected items have been addressed on the plans.
Carlsbad 96-1074
June 27, 1996
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 96-1074
PREPARED BY: Kurt Culver DATE: June 27, 1996
BUILDING ADDRESS: 2604-A El Camino Real
BUILDING OCCUPANCY: A3 TYPE OF CONSTRUCTION: V-N
BUILDING PORTION BUILDING AREA
(ft 2)
VALUATION
MULTIPLIER
VALUE
($)
TI 2450 36 88200
Air Conditioning
Fire Sprinklers
TOTAL VALUE i 88,200
1991 UBC Building Permit Fee J Bldg. Permit Fee by ordinance: $ 590.00
1991 UBC Plan Check Fee Plan Check Fee by ordinance: $ 383.50
Type of Review: Z Complete Review LI Structural Only Hourly
Repetitive Fee Applicable LI Other:
Esgil Plan Review Fee: $ 306.80
Comments:
Fire Services Review: Ej Complete Review E] Suppression System
fl Fire Alarm Other:
Esgil Fire Services Review Fee:
Comments:
Sheet I of I
macvaluedoc 5196
..'
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 st-2ndv' 3rd/
L2' El El 1. Provide a fully dimensioned site plan drawn to scale. Show:
North Arrow D. Property Lines Easements
Existing & Proposed Structures E. Easements
Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
0 2. Show on site plan:
Drainage Patterns C. Existing Topography
Existing & Proposed Slopes
I2I" El 0 3. Include note: "Surface water to be directed away from the building foundation at a 2%
gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)."
[Per 1985 UBC 2907(d)5].
On graded sites, the top of any exterior foundation shall extend above the elevation
of the street gutter at point of discharge or the inlet of an approved drainage device
a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.).
EV' 0 0 4. Include on title sheet
Site address
Assessor's Parcel Number
Legal Description •
For commercial/industrial buildings and tenant improvement projects, include: Total
building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses (manufacturing, warehouse, office,
etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
P:\D0cS\CHIQS1\8O0I .FRM Page 1 of 4 •
-•
pv 043o,9
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
lstV 2ndV 3rdV
0 0 5. Project does not comply with the following Engineering Conditions of approval for
Project No.
Conditions were complied with by: Date:
DEDICATION REQUIREMENTS
O 0 0 6. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $________________ -pursuant to Code
Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8-1/2" x 11" plat map
and submit with a title report. All easement documents must be (approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Provide the
completed application form and the requirements on the checklist at the time of
resubmittal.
Dedication completed by • Date:
IMPROVEMENT REQUIREMENTS
O 0 0 7a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the construction
exceeds $ -pursuant to Code Section 18.40.040.
Public improvements required as follows:
Please have a registered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for a
separate plancheck process through the Engineering Department. Improvement
plans must be approved, appropriate securities posted and fees paid prior to
issuance of permit.
Attached please find an application form and submittal, checklist for the public
improvements requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmittal.
Improvement Plans signed by: Date:
P:\DOCS\CHKLSY\BP0001.FRM Page 2 of 4 REV 04/30/96
BUILDING PLANCHECK CHECKLIST
1st" 2nd' 3rd'
El Cl El Construction of the public improvements may be deferred pursuant to code Section
18.40. Please submit a recent property title report or current grant deed on the • property and processing fee of $ . so we may prepare the
• necessary Future Improvement Agreement. This agreement must be signed, notarized
and approved by the City prior to issuance of a Building Permit.
Future public improvements required as follows:____________________________
Improvement Plans signed by: Date:___________
O 0 0 Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
Future Improvement Agreement completed by:____________________________
/ Date:_________________
." 0 0 7d. No Public Improvements required. SPECIALNOTE:Damagedordefective
improvementsfoundadiacenttobuildingsitemustberepairedtothesatisfactionof
the City_Inspector prior tooccupancy. •• -; •
GRADINGPERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the Municipal Code.
• •
O 0 0 Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
O 0 0 Grading Permit required. A separate grading plan prepared by a registered Civil
• Engineer must be Submitted together with the completed application form attached.
NOTE:The Grading _Permit must be issued andrough grading approval obtained prior
to issuance of a Building Permit.,• ••
- • Grading Inspector sign off by: Date:
0 8c No Grading Permit required
\oOcscS1NBpocO1.F • • Page 3 of 4 • •: •
BUILDING PLANCHECK CHECKLIST
MISCELLANEOUSPERMITS
o1st \2Adv' 3rd-,./
'D 0 9. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private
work adjacent to the public Right-of-Way. Types of work include, but are not limited
to: street improvements, trees, driveways, tieing into public storm drain, sewer and
water utilities.
Right-of-Way permit required for
A separate Right-of-Way permit issued bythe Engineering Department is required for
the following:
ZE03,4*1 0. A SEWER PERMIT is required concurrent with the building permit issuance. Thefee
( is noted in the fees section on the following page. .
0 11. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste
Permit Application Form and submit for City approval prior to issuance of a Permit.
Industrial waste permit accepted by: Date:
&A
74# / C&L
£JaiZf 5
•
P:\DOcS\CHIQST\9P000I.FRM Page 4 of 4 • REV 0O/96
ENGINEERING DEPARTMENT ENGINEERING REVIEW SECTION
FEE CALCULATION WORKSHEET
C3 Estimate based on unconfirmed iriformation from applicant.
El Calculation based on building plancheck plan submittal.
Address: c 4A- (J (?&A.P Bldg. Permit No.
Prepared by/'21??i,4't Date:4/9 Checked by: Date:___________________
EDU CALCULATIONS. List types and square fo-otages for &I -
Types fUse: fs t
Total EDU $ e 3! ADI CALCULATIONS: Ustpes and square footages for al ues.
,
, 72
Types of Use: ali~ Sq. Ft.IUnits: ADTs:.' S'5
Total ADTs____________
FEES REQUIRED:
PUBLIC FACILITIES FEE REQUIRED 0 YES 0 NO (See Building Department for amount)
WITHIN CFD: 0 YES (no bridge & thoroughfare fee, 0 NO
reduced Traffic Impact Fee)
1. iIN.LJEU FEE PARK AREA:________
FEE/UNIT: X NO. UNITS: =$_____________
0'2.TRAF1C iMPACT FEE
ADTs/UNITS: 3 (9 7 X FEE/ADT: c =
DGE AND THOROUGHFARE FEE
ADTs/UNITS: X FEE/AOl: =$ -(9
ACIU11ES MANAGEMENT FEE ZONE:________
SQ.FT.: X FEE/SO.FT.: =$___________
A. FEE/EDU:/(O
BENEFIT AREA: DRAINAGE BASIN:______
EDU's: X FEE/EDU: =$_____________
DR'AINAGE FEES PLDA : HIGH ______/LOW______
ACRES: X FEE/AC: =$____________
SEWER LATERAL ($2500 DEPOSIT) =$ _C
0 8. WATER FEE
EDU's: X FEE/EDU:________
TOTAL OF ABOVE FEES*:
This calculation sheet Is NOT • complete list of all 1... which maybe due. . Dedications and Improvements may also be required with Building Permits.
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB 7b- If) 79 Address ''D 1.9
.
C.
Planner ti 1-.. 1fr/<' 9//,&V Phone (619).4'38-1161 ext. (Name) 0
Type of Project and Use: £
Zone: /L9 Facilities Management Zone:______________
CFD (in/out) # s *
circle (If property in, complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department)
Legend
M 9 Item Complete
Item Incomplete - Needs your action
E1 i' 0 Environmental Review Required: YES NO V TYPE
DATE, OF COMPLETION:
' 0 5
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval 0
0
/ 0 - EZ( 0 Discretionary Action Required YES NO '—' TYPE 's £4s'' •.' 'i
APPROVAL/RESO NO '. DATE
PROJECT NO.
OTHER RELATED CASES: •
0 0 0
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval 0
0 0
0
J •. .5 -.
E( I"D California Coastal Commission Permit Required: YES 0 NO
DATE OF APPROVAL: •0
San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA 92108
(619) 521-8036 0 0
Compliance with conditions of approval? If not, state conditions 'which require action.
Conditions of Approval .
0
( I( 0 IncIusionary Housing Fee required: YES NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993).
Site Plan:
0 -. Provide a fully dimensioned site plah drawn to scale. Show: North arrow, property
lines, easements, existing and proposed structures, streets, existing street'
improvements, right-of-way width, dimensioned setbacks and existing topographical
lines.
Provide legal description of property, and assessor's parcel number.
Zoning:
.
1. Setbacks:
Front: Required -& 'Shown
Int. Side: Required Shown
Street Side: Required . -' Shown
Rear: Required - -. 'Shown
2.. Lot Coverage: Required . - Shown
Height: Required . 3S Shown
L" 0 Parking: . Spaces Require tilfrfr1' i6wfr'
Guest Spaces Required Shown
-
-- - -
/ -
/
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE 74,
K:\ADMIN\COUNTER\PLANCKFRM 1-17-96
City of Carlsbad 96153
Fire Department • Bureau of Prevention
Plan Review: Requirements Category: Building Plan Check
Date of Report:Monday, June 24, 1996 Reviewed by: 1 VA..
Contact Name Bill Kerr
Address 4655 Cass St Ste 200
City-,State San Diego CA 92109
Planning No.
Job Name - Rubio's Restaurant
Job Address 2604 El Camino Real Ste. or Bldg. No.
Approved - The item you have submitted for review has been approved. The approval is
based on plans; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure
to comply with instructions in this report can result in suspension of permit to
construct or install improvements.
El Disapproved - Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.
For Fire Department Use Only
Review 1st 2nd 3rd
Other Agency ID
CFD Job# 96153 File#___________
2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121
City of Carlsbad 96153
Fire Department . • Bureau of Prevention•
General Comments:
Date of Report:Monday, June 24, 1996
Contact Name Bill Kerr
Address 4655 Cass St Ste 200
City, State San Diego CA 92109
Bldg Dept. No. 96-1074 Planning No.
Job Name Rubio's Restaurant
Job Address 2604 El Camino Real Ste. or Bldg. No. A
Hood and duct system is to be permitted separately by Fire Department.
2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121