Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2606 JACARANDA AVE; ; CB151761; Permit
City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 09-04-2015 Residential Permit Permit No: CB151761 Building Inspection Request Line (760) 602-2725 Job Address: 2606 JACARANDA AV CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No:. 2551132600 Lot #: 0 Applied: 06/08/2015 Valuation: $102376.00 Constuction Type: 513 Entered By: JMA Occupancy Group: Reference #: Plan Approved: 09/04/2015 # Dwelling Units: 0 Structure Type: Issued: 09/04/2015 Bedrooms: 0 Bathrooms: 0 Inspect Area: Orig PC #: Plan Check #: Project Title: HISHMEH: 281 SF ADDITION //841 SF INTERIOR REMODEL Applicant: Owner: EIRC JOHNSON HISHMEH RICHARD E JR&AMBER L 31 MCNEILL AVE 2606 JACARANDA AVE ENCINITAS CA 92024-3623 CARLSBAD CA 92009 760-889-6132 Building Permit $636.65 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $445.66 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $13.31 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $77.00 Renewal Fee $0.00 ELECTRICAL TOTAL. $45.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $63.25 Other Building Fee . $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (SB 1473) Fee $5.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $1,285.87 Total Fees: $1,285.87 Total Payments to Date: $1,285.87 Balance Due: $0.00 FINAL APPROVAL Inspector: Vu. /'< Date: __________. Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FuRTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given p NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. • City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit 09-04-2015 Permit No:SW150235 Job Address: 2606 JACARANDA AV CBAD Permit Type: SWPPP . Status: ISSUED Parcel No: 2551132600 Lot #: 0 Applied: .06/08/2015 Reference #: Entered By: JMA CB#: CB151761 Issued: 09/04/2015 Inspect Area: Project Title: HISHNEH: 281 SF ADDITION Tier: 1 Priority: L Applicant: Owner: ERIC JOHNSON HISHMEH RICHARD E JR&AMBER L 2606 JACARANDA AVE CARLSBAD CA 92009 760-889-6132 • Emergency Contact: ERIC JOHNSON 760-889-6132 SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES $48.00 $58.00 $0.00 $106.00 Total Fees: $106.00 Total Payments To Date $106.00 Balance Due: $0.00 FINAL APPROVAL DATE eL/2 4ii CLEARANCE__________ SIGNATURE VL4. t& -V ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: KPLANNING 'GINEERING SUILDING 0 FIRE 0 HEALTH DHAZMATIAPCD I cbity f Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 email: building©carlsbadca.gov www.carlsbadcagov Plan Check No. Ct Vaiu I, 1(0 O Plan Ck. Deposit Date G.' • 1 Iswppp j JOB ADDRESS 26 SUflt#/SPAcE#/UNrr# I APN CT/PROJECT# 1LOT# IPHASE# 1#OFUNITS l i# BEDROOMS iLt #BAThROOMS 19 ITENANTBUSiNESSNAME Ic0NSTR.TYPE I I5 I OcC.GROUP IT...-' DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) "2-B\ Sir,lo V12.t \'&h XIS71NGUSE PROPOSED USE I t*L GARAGE (SF) I PATIOS(SF) DECKS I (SF) IFIREPLACE JYESD& NODI IAIRCONDITIONING YES DNODI IFIRESPRINKLERS YES[:] NO[::] APPLICANT NAME PROPERTY NAME ADDRESS ADDRESS tc CITY STATE ZIP art' STATE ZIP -" C PHONE FAX I PHONES FAX I EMAIL "(1_0 Cae'\.e EMAIL DESIGN PROFESSIONAL CONTRACTOR BUS. NAME ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL STATE UC. a STATE UC.# CLASS CITY BUS. UC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to files signed statement that he is licensed pursuant to the provisions of the Contractor's License Law[Chapter 9, commending with Section 7000 of Division 301 the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 1 11111 1111111 111111 1111 111 11~111 111111 111 1 — 1 I'v Workers Compensation Declaration: I hereby affirm under penally of pe'juiy one of the following declarations: R I have and will maintain a certificate of consent to self-Insure for workers' canpensatiai as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers compensation, as required bY Section 3700 of the Labor Coda, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Policy No. Expiration Dale section need not be completed if the permitis for one hundred dollars ($100) or less. Certificate of Exemption: (certify that in the performance of the work for which this pemnill is issued, I shall not employ any person in any manner so as to become suect to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,00(1), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE DAGERT DATE I TV IF thereby affirm that lam exempt from Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon, and who does such W9rk himself or through his own employees, provided that such tinprovernents are rd intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am ssclusivety contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not applyto an owner of property who builds or improves thereon, and contracts for such prects with contractor(s) licensed pursuant to the Conlractofs License Law). [J I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. Dyes Dt'io I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5.1 will provide some 01 the work, but I have contracted (hired) the following persons to provide the work indicated (include name! adoressl ptrone/ type of work): "PROPERTY OWNER SIGNATURE []AGENT DATE ___137317t108 JOGOøO (®C 0000000 12300098 (J(37 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25&, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air q.jality management district? DYes 0 No ls the facility tobe constructed withn lfeat ofthe outer boundary ofasch site? DYes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CER11FICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. (3008VOUMV000 COG30000 I hereby affirm that there is a construction tending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name . Lender's Address 0€01 @0010@000 have Information on the plans Isaimte. I agree to complywith all City ordinances and Stale laws telatingto building construction. I hereby authcree reprmnlatrve of to Cdy of Carlsbad to enter upon the above maitioned propertyftcirechenpurpose I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OFCARLSBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH AY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OFThE GRANTING OF THIS PERMIT. OSHA: An OSHA pennfl is required for excavations ov&5l)'dØ~ndd orconsbn of sfructkuesw&3stones N haight. EXPIRATION: Every perm it issued by the Building Official u 1"r the p of this Code shall wpire by lhbtiDn and become null and vdd if the building or vork audwized by such permit is not commenced Whn 180 days from the data of such permit or llthebuiogt auth by such permit is suspended orabandoned at any time after the esxk is commenced for aperiod of 180 days (Section 106.4.4 Uniform Building Cole). "APPLICANT'S SIGNATURE DATE 6. , i Inspection. List Permit#: CB151761 Type: RESDNTL RAD HISHMEH: 281 SF ADDITION 1/841 SF INTERIOR REMODEL Date Inspection Item Inspector Act Comments 01/26/2016 89 Final Combo - RI 01/26/2016 89 Final Combo MC Fl 01/22/2016 89 Final Combo - RI 01/22/2016 89 Final Combo 11VIC CO NOTICE 11/20/201,5 27 Shower Pan/Roman Tubs PY AP 11/17/201517. Interior Lath/Drywall MC AP DRYWALL ONLY 11/17/2015 18 Exterior Lath/Drywall MC AP 11/13/2015 16 Insulation MC AP 11/12/201584 Rough Combo MC AP 11/05/2015 13 Shear Panels/HD's MC AP 10/29/201515 Roof/Reroof MC AP 10/21/2015 22 Sewer/Water Service MC AP WASTE, BUILDING STUB TO P.O.C. 10/15/2015 66 Grout MC AP 2ND LIFT 10/09/2015 66 Grout PY PA 1st lift 09/21/2015 11 Ftg/Foundation/Piers MC AP 09/18/2015 11 Ftg/Foundation/Piers MC , NR 09/17/2015 21 Underground/Under Floor MC AP WASTE ONLY TO BLDG. LINE 09/17/2015 22 Sewer/Water Service MC NR - Tuesday, January 26, 2016 - . Page 1 of 1 -( -'..-- . - •- : ' - .- - - - (•__ P.O. Box 2450 -• r= Alpine, CA 91903 Phone 619-540-0612 Fax 619-445-5889 Inspection & MteriaI Testing DAY J DATE .s- COVERING WORK PERFORMED REQUIRING APPROVAL BY THE SPECIAL INSPECTOR OF: L1 Reinforced Concrete LI Reinforced Masonry U Struct. Steel Assembly (One inspection per Report) U Pre-Stressed Concrete U Fireprooflng Other:°r Project Nark,/ , / Project No: Pemit/AppIication .fIo:Plan.-File 57 No: Project S(reet Address Jurisdictipi Project Plans/Specifications Title & Date (Revision) Architect Eni7 General Contractor / Contractor Doing Reported Work. CODE DESCRIPTIONS OF WC~Rlk INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED: NUMBER, TYPE, &.IDENTIFICATION NUMBERS OF TEST SAMPLES tvo- (2)qo- Jac a. ,' I C,*ee • AIJ i /,c w d d#z 41,-7 77 ___ 00, ' 4ra. 2/,'x ' ?é4s • 4zc (Q m571r-. Iz7,a, iV -. J.7 yr ... •. \ TIME ON SITE TIME OFF SITE RIG. RS- O.T. - HOURS # OF TEST SPECIMENS ( - - >.INIaafReistered Inspector (Print) - Signature of Registered Inspector JOB SITE CONTACT IS ASKED TO SIGN TO VERIFY INSPECTION HOURS ONLY. THE CONTENT OF THIS REPORT AND FEE GlIARGES ARE THE RESPONSIBILITY OF OTHERS. __________________________________ A Date of Report Registered Number fii III ,j CERTIFICATE OF COMPLIANCE -Signature: - - V IJI ( VV . TO THE BEST OF MY KNOWLEDGE, THE ABOVE REPORTED WORK,LINLESS UNLESS - - Owner -Authorized JobSite Contact • OTHERWISE NOTED, IS IN CONFORMANCE WITH THE APPROVED PLANS AND - - • : SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE - - - • GOVERNING STANDARDS. - - L EsGil Corporation In (Partnership with government for cBui(iing Safety DATE: 07/30/2015 U APPLICANT U JURIS. JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 15-1761 SET: H PROJECT ADDRESS: 2606 Jacaranda Ave. PROJECT NAME: SFD addition and remodel for Hishmeh residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficienóies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. II1 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Eric Johnson Telephone #: 760-889-6132 Date contacted: (by: ) Email: eaj62cornell.edu Mail Telephone Fax In Person REMARKS: A - All sheets of plans must be signed by the person responsible for their preparation. B - Applicant shall reproduce the clouded notes (for smoke alarms missing) included on sheet D-2.1 of the approved plans in all sets of plans remaining at the City. By: Chuck Mendenhall (SA) Enclosures: EsGil Corporation E] GA L1EJLMB 17-1 PC 07/27/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partners flip with government for Bui(dIng Safety DATE: 06/18/2015 JURISDICTION: City of Carlsbad UPPLICANT JURIS. U PLAN REVIEWER U FILE PLAN CHECK NO.: 15-1761 SET: I PROJECT ADDRESS: 2606 Jacaranda Ave. PROJECT NAME: SFD addition and remodel for Hishmeh residence LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: El EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Eric Johnson Telephone #: 760-889-6132 .2'te coacted: %Q4 ('1 (by:'-)- Email: eaj62cornell.edu MaiI Vièlephone Fax In Person LII REMARKS: By: Chuck Mendenhall (SA) Enclosures: EsGil Corporation [:1 GA L]EJ LIMB F] PC 06/11/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 City of Carlsbad 15-1761 06/18/2015 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 15-1761 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2606 Jacaranda Ave. FLOOR AREA: SFD 281 SF SFD REM 841 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 6/8/15 DATE INITIAL PLAN REVIEW COMPLETED: 06/18/2015 STORIES: 1 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 06/11/15 PLAN REVIEWER: Chuck Mendenhall (SA) FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 15-1761 06/18/2015 . PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and àalculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). . FIRE PROTECTION An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings (not required for additions if the existing dwelling doesn't already have a sprinkler system). Please clearly note this on the plans. Section R313.2. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.3.1. Please show the required smoke alarms at the existing bedrooms and at the hallways/rooms/areas giving to existing bedrooms. City of Carlsbad 15-1761 06/18/2015 Specify on the plans that any existing smoke alarms that are more than 10 years old will be replaced. Section R314.3.2. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. Please show it on plans outside of the new proposed Master Bedroom. NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 8. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. Please show the required carbon monoxide alarms at the hallways/rooms/areas giving to existing bedrooms. GENERAL RESIDENTIAL REQUIREMENTS 9. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: Glazing in doors. Door 3 Glazing adjacent to a door where the nearest vertical edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60" above the walking surface. Windows G and F ROOFING 10. Specify on the plans the following information for the roof materials, per Section R106.1.1: Manufacturer's name and product name/number. ICC approval number, or equal. SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. City of Carlsbad 15-1761 06/18/2015 Show the required ventilation for enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters. The minimum vent area is 1/150 of enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters. Show on the plans the area required and area provided. Section R806.2. Enclosed rafted spaces do not require venting if the following specific insulation design is used, per Sections R806.5/EM3.9.6: If the insulation is air-permeable and it is installed directly below the roof sheathing with, rigid board or sheet insulation with a minimum R-4 value installed above the roof sheathing. (or) If the insulation is air-impermeable and it is in direct contact with the underside of the roof sheathing. (or) If two layers of insulation are installed below the roof sheathing: An air- impermeable layer in direct contact with the underside of the roof sheathing and an additional layer of air permeable insulation installed directly under the air-impermeable insulation. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be.provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1 clearance, member sizes may have to be increased for rafter-ceiling joists. Section R806.3. Note on the plans: VENTILATION OPENINGS FOR THE ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH 1/16" MINIMUM TO 14" MAXIMUM OPENINGS. Section R806.1. . FOUNDATION REQUIREMENTS All new residential buildings, including additions, require a soils report. An update letter is required if the report is more than 3 years old. If a room addition is less than $OO sq. ft. in area and only one story, then a soils report is not required. The maximum allowable soil bearing value used in any design must be 1000 psf for this exception. Under this condition, Esgil staff should advise the City (upon final transmittal) to place their "soils notice" stamp on the plans. Carlsbad has ruled that a stand-alone accessory dwelling unit, if under 500 square feet, may also qualify for this exception. a) Provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. Show distance from foundation to edge of cut or fill slopes ("distance-to- daylight") and show slope and heights of cuts and fills. Section R403.1.7. City of Carlsbad 15-1761 06/18/2015 . FRAMING 17. Provide structural design calculations for the CMU walls. Additional corrections may follow. 18. Please revise the structural calculations provided to include the CMU walls in the dead load calculations provided on sheet 1. 19. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2) a) Masonry construction. Special inspection should be provided for all masonry construction in accordance with Section 1705.4. . MECHANICAL 20. Show on the plans the location, type and size (BTU's) of all heating and cooling appliances or systems. 21. Specify on the plans the following information for the fireplace(s): Manufacturer's name/model number and ICC approval number, or equal. Show the height of the factory-built chimney above the roof and the horizontal clearances per listing approval. Chimneys shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet. CIVIC Section 802.5.4. Note on the plans that approved spark arrestors shall be installed on all chimneys. CRC Section R1003.9. Decorative shrouds shall not be installed at the termination of chimneys for factory-built fireplaces, except where such shrouds are listed and labeled for use with the specific system and installed in accordance with the manufacturer's installation instructions. Section R1004.3. . ELECTRICAL 22. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. 23. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. 24. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). Weather resistant type for receptacles installed in damp or wet locations (outside). Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.8(A): Family, living, bedrooms, dining, halls, etc. City of Carlsbad 15-1761 06/18/2015 Show at least one wall switch-controlled lighting outlet to be installed in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at the exterior side of outdoor entrances or exits. At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps. CEC Article 210.70(A). . PLUMBING Show water heater size (1st hour rating), type, and location on plans. Note on the plans that "combustion air for fuel burning water heaters will be provided in accordance with the Plumbing Code". Show the T and P relief valve at the water heater and the discharge pipe size and routing to the exterior. CPC Section 608.3. Provide a note on the plans: The control valves in showers, bathtubs, and bidets must be pressure balanced or thermostatic mixing valves. CPC Sections 408, 409, 410. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.5 GPM, and showerheads may not exceed 2.0 GPM of flow. CPC Section 403 and 408. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that. existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. . RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that in the building's conditioned area, volume or size CGC Section 303 1 1 Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. City of Carlsbad 15-1761 06/18/2015 Storm water drainage/retention during construction. Note on the plans: Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, wattle or other approved method. CGC 4.106.2. Grading and paving. Note on the plans that site grading or drainage system will manage all surface water flows to keep water from entering buildings (swales, water collection, French drains, etc.). CGC 4.106.3. Exception: Additions not altering the drainage path. Note on the plans that automatic irrigation system controllers shall comply with the CGC Section 4.304.2 as follows: A. Controllers shall be weather or soil moisture based that automatically adjust irrigation in response to changes in needs as weather conditions change. B. Weather based controllers shall have separate wired or wireless rain sensor which connects or communicates with the controller(s). Soil moisture based controllers are not required to have rain sensors. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC 4.410.1. Note on the plans that the gas fireplace(s) shall be a direct-vent sealed- combustion type. Woodstove or pellet stoves must be US EPA Phase II rated appliances. CGC 4.503.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. City of Carlsbad 15-1761 06/18/2015 Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified in Section 4.505.3. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC 4.505.3. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. . ENERGY CONSERVATION Include on the Title Sheet of the plans the following statement: "Compliance with the documentation requirements of the 2013 Energy Efficiency Standards is necessary for this project. Registered, signed, and dated copies of the appropriate CF1 R, CF2R, and CF3R forms shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." All hot water piping sized 3/4" or larger is required to be insulated as follows: 1" pipe size or less: 1" thick insulation; larger pipe sizes require 11/2' thick insulation. Note: In addition, the 1/2" size hot water pipe to the kitchen sink is required to be insulated. ES 150.00)2 Below grade hot water piping is required to be installed in a waterproof and non- crushable sleeve or casing that allows for replacement of both the piping and insulation. ES 150.00) SEE NEXT PAGE FOR ADDITIONAL INFORMATION. City of Carlsbad 15-1761 06/18/2015 . MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Ll No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall (SA) at EsGil Corporation. Thank you. 'City of Carlsbad 15-1761 06/18/2015 (DO NOT PAY— THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-1761 PREPARED BY: Chuck Mendenhall (SA) DATE: 06/18/2015 BUILDING ADDRESS: 2606 Jacaranda Ave. BUILDING OCCUPANCY: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) SFD ADD. 281 157.88 44,364 SFD REM 841 68.98 58,012 Air Conditioning Fire Sprinklers TOTAL VALUE 102,376 Jurisdiction Code Icb 113y ordinance I Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: Complete Review Structural Only I $636.711 I $41 3.861 Repetitive Fee Repeats Other Hourly EsGil Fee Hr. @ * I $356.561 Comments In addition to the above fee, an additional fee of $43 OOis due (0 5 hour $86 00/hr )fo the CalGreen reveJ Sheet of 1 macvalue.doc + - CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov 11 DATE: 07/28/2015 PROJECT NAME: HISHMEH PROJECT,ID:CB151761 PLAN CHECK NO: 2 SET#: 1 ADDRESS: 2606 JACARANDA AVE APN: 255-113-26-8 VALUATION: $91,960 SCOPE OF WORK: RES ADD OF 281 TO EXISTING 1722 SF + INTERIOR REMODEL >< This plan check review is complete and has been APPROVED by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by Construction Management & Inspection Division is required: Yes No To determine status by one or more of these divisions listed below, please contact 760-602-2719. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on F-1 the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: EAJ62@CORNELL.EDU - CA 1TIIJ3 ENGINEERING tJt1!Z1B1111 ' `360-602-2750, Chris Sexton - Chris Glassen 1 Greg Ryan 760-602-4624 -, 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christopher.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz F-1V Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 I - 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov -. ValRay Nelson T Dominic Fieri 760-602-2741 - 760-602-4664 ValRay.Marshall@carlsbadca.gov Remarks: HISHMEH PLAN CHECK NO # 2 Outstanding issues are marked with X . Items that conform to permit requirements are marked with I or have intentionally been left blank.. 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: X [1 North arrow Driveway widths Li Existing & proposed structures E 1 Existing or proposed sewer lateral X / Existing street improvements Existing or proposed water service X / Property lines (show all dimensions) '. Submit on signed approved plans -. Easements DWG No. X / Right-of-way width & adjacent streets Show on site plan: X I Drainage patterns ........... - Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining - street or an approved drainage course. ADD THE FOLLOWING NOTE Finish grade will provide a minimum positive drainage of 2% to swale 5 away from building. I Existing & proposed slopes and topography Size location alignment of existing or proposed sewer and water service(s) that serves the project Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. LJ L.J Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: 'iJ Site address / Assessors parcel number X / Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: lot 303 of map 8362 Subdivision/Tract: CT 7348 Reference No(s): E-36 Page 2 of 6 REV 6/01/12 HISHMEH PLAN CHECK NO# 2 DISCRETIONARY APPROVAL COMPLIANCE J Project does not comply with the following engineering conditions of approval for project no DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 24000.00 pursuant to Carlsbad Municipal Code Section 18.40.030. E] EIIJ Dedication required as follows: IMPROVEMENT REQUIREMENTS :-]All needed public improvements upon and adjacent to the building site must be constructed N/A --- at time of building construction whenever the value of the construction exceeds $120000.00, pursuant to Carlsbad Municipal Code Section 18.40.040. LiJ Public improvements required as follows: EIIIJ Construction of the public improvements must be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee, so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the city prior to issuance of a building permit. j Future public improvements required as follows: E-36 Page 3 of 6 REV 6/01/12 N/A N/A HIS H ME H PLAN CHECK NO # 2 GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. EJ =Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" P Grading Permit required. NOTE:. The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector The inspector will then provide the engineering counter with -a release for the building permit. No grading permit required. Minor Grading Permit required. See additional comments for project- specific requirements. MISCELLANEOUS PERMITS RIGHT-OF-WAY ,PERMIT is required to do work in city right-of-way and/or private work N/A adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Li Right-of-way permit required for: E-36 Page 4 of 6 1 REV 6/01/12 HISHMEH PLAN CHECK NO #2 7. STORM WATER -APPLICANT- MUST SIGN SIGNED 7/29/15 Construction Compliance Dj E2IJ Project Threat Assessment Form complete. JJ Enclosed Project Threat Assessment Form incomplete. T] Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW15-235 ] [1 Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance [21J Storm Water Standards Questionnaire complete. EIJ Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. http://wwwcarlsbadcaqov/business/building/DocumefltS/EflgStafldSW-StdS-V014-Ch2.Pdf El E Project needs to incorporate low impact development strategies throughout in one or more of the following ways: Rainwater harvesting (rain barrels or cistern) j Vegetated Roof [ Bio-retentions cell/rain garden LJ Pervious pavement/payers Eli Flow-through planter/vegetated or rock drip line Li Vegetated swales or rock infiltration swales [J Downspouts disconnect and discharge over landscape Other: E-36 Page of 6 REV 6/01/12 Required fees have been entered in building permit. Drainage fee applicable Added square feet Added square footage in last two years? [1 yes [J no Permit No. Permit No. Project built after 1980 E] yes- Ono Impervious surface> 50% Jyes 11 no Impact unconstructed facility [jyes Ono Fire sprinklers required Eiyes jno (is addition over 150 from center line) Upgrade 0 yes No fees required HISHMEH PLAN CHECK NO #2 8. WATER METER REVIEW Domestic (potable) Use OLIVENHAIN L.J ITT] What size meter is required? WD 'T] [J Where a residential unit is required to have an automatic fire extinguishing system the minimum meter size shall be a 1' meter. 760-753-6466 NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. ::i 2IJ For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be 3/4". 10. ADDITIONAL COMMENTS PLEASE CONTACT OLIVENHAIN WATER DISTRICT TO. DETERMINE IF AN UPGRADE FOR METER IS NEEDED Attachments: Engineering Application Storm Water Form Right-of-Way Application/ Info Reference Documents E-36 Page 6of6 REV 6101/12 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: Date: GEO DATA: LFMZ: iB&T: Address: Bldg. Permit #: Fees Update by: Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: 0 Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq,Ft./Units ADT's: Types of Use: Sq.Ft,/Units ADT's: Types of Use: Sq.Ft./Units ADT's: FEES REQUIRED: Within CFD:flYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) ONO 1. PARK-IN-LIEU FEE: [INW QUADRANT EJ NE QUADRANT OSE QUADRANT OW QUADRANT ADT'S/UNITS: X FEE/ADT: 2.TRAFFIC IMPACT FEE: ADT'S/UNITS: X FEE/ADT: S BRIDGE & THOROUGHFARE FEE: EDIST.#1 EDIST.#2 EDIST.#3 (USE SANDAG)ADT'S/UNITS X FEE/ADT: FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: X FEE/SQ,FT./UNIT: SEWER FEE EDU's X FEE/EDU: BENEFIT AREA: EDU's X FEE/EDU: 4 6 DRAINAGE FEES PLDA flHIGH Li MEDIUM TILOW ACRES: X FEE/AC: 7. POTABLE WATER FEES: UNITS I CODE I CONN, FEE I METER FEE I SDCWA FEE TOTAL ***This may not represent a comprehensive list of fees due for this project. Please contact the Building division at (760) 602719 for a complete listing of fees*** Prcjecl Adess: Assessor Parcel No. J* (' c 255 t Owner/Owner's AulIrized Agent Nane: Title: Owner/Ow 'S Author4nt Signalur Date: - ~ 7.tt1.tT City Concurrence: By: Date: Project ID: 11 NO 'JJ 1111 I5fl(oi Page 1 of 1 Rev.03/09 STORM WATER DeveloDment Services CITY <04_> OF COMPLIANCE BuildingDivision CARLSBAD ASSESSMENT 1635 Faraday Avenue 760-602-2719 B-24 www.carlsbadca.gov I am applying to the City of Carlsbad for the following type(s) of construction permit: 23 Building Permit L3 Right-of-Way Permit U My project is categorically EXEMPT from Electrical .: Patio/Deck the requirement to prepare a storm water Fire Additional Photo Voltaic pollution prevention plan (SWPPP) because it Fire Alarm Re-Roofing only requires issuance of one or more of the 'JjJ1TT Fixed Systems Mechanical Sign Spa-Factory following permit types: Mobile Home Sprinkler Plumbing Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Criteria U My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Tier I - Low Threat Assessment Criteria My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: Results in some soil disturbance; and/or Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 - Moderate Threat Assessment Criteria U My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (chapter 15.16 of the Carlsbad Municipal Code); or, Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or Construction will be initiated during the rainy season or will extend into the rainy season (Oct 1 through April 30). Tier 3 - Significant Threat Assessment Criteria U My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or U My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, U My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. "The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Construction SWPPP Tier Level is warranted. B-24 STORM WATER POLLUTION PREVENTION NOTES ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPECIAL NOTES PROJECT INFORMATION Site Address: Assessors Parcel Number: Project ID: Sw Construction Permit No.: C?S tS. 7 (, I Estimated Construction Start Date Project Duration Months Emergency Contact: Name: 1L 24 hour Phone: i3t Perceived Threat to Storm Water Quality o Medium Low If medium box is checked, must attach a site plan sheet showing proposed work area and location of proposed structural BMPs For City Use Only ((4> CITY OF CARLSBAD STORM WATER COMPLIANCE FORM TIER I CONSTRUCTION SWPPP E-29 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov STORM WATER COMPLIANCE v' My project is not in a category of permit types exempt from the Construction SWPPP requirements I My project is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code) I My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more of the additional following criteria: located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. CITY OF CARLSBAD STANDARD TIER 1 SWPPP OWNE(S)/O\ V ER'S AGENT NAME (PRINT) '7 OWNER(S)/NERS AGENT NAME (SIGNATURE) DATE Approved By: Date: (S 1I-(' E-29 Pagel of 3 REV 4/30/10 U) OQCDg (1)3 CD - Co .. -CD (D a) RU) (D -so. --() Cfl(2• (DO C(0CDcr 0U) (U mU)og O)CD 0:, U)(UCDU) CD CD o 0 U) U) - - (I) - 0. CDar g -g O 2. (D ~:a g- - Qø CD,OOU)U) O< O )+0) C .cD2 CD 3 C . U) (0 CmCDo U) 'U)_ o —3z,-.- -. CD 5 CD WE. CDC - og __w 0 3iCDO >_u flI1Q) O(D3 (CD OCD Ch 0CD05(D, (• DOO Cr O I U) 0 C a ID O _ 0 flU)CD U)S < U)O=ID Q _ . O-•' D E° -- (D O PU)öOCD U- CD CD -CD 00. U) .00 0.o -O o U) U) (no C)!O. .0 0) CD 0) 0 C --g .Th (D U) -• O _-o_Co q U) x> o _O (U (D -o1 a:CL ID CD (DOq(D(Dg CO" ug. U)5 0-0. 0 U)_...CD Th CD -0 °U)cO CD0. CD-' EL. 04i8 (D2>3O CD -CD - (flOU)-0 U) ju 3 CD ~goLp 3S O(UU) U)0. -' _• m<92=9$:-, -' a - U) a (0-. -. -. ?D - 0 CD D (C) M Co 0 0 W O(nQCImwou0o0ocn—lG) -.0-. 0 K - • Ct -u CO --. c D - U) DD -o cn - g U) > CD • 4. CD EC-7 Geotextiles & Mats EC-8 Wood Mulching ca C1 - Earth Dikes and - .-------- Drainage Swales 0 . ----- Cr EC-il Slope Drains a SE-1 Silt Fence SE-3 Sediment Trap SE4 Check Dam Cl) a 3 SE-5 Fiber Rolls SE-6 Gravel Bag Berm - - - - - - - - - - - - - - - - - - - - SE 7 Street Sweeping and a - Vacuuming SE-8 Sandbag Barrier SE-10 Storm Drain Inlet Protection TRA Stabilized Construction Ingress/Egress 0 Co o M TR-2 Stabilized Construction Roadway aco NS-1 Water Conservation Practices NS-3 Paving and Grinding ODerations NS-7 Potable Water/Irrigation NS-8 Vehicle and Equipment Cleaning WM-i Material Delivery and Stor2ae WM-2 Material Use VCD WM-3 Stockpile Management WM4 Spill Prevention and OE Control WM-5 Solid Waste Cr a Manaaement M CL WM-6 Hazardous Waste M2nac1ement WM-8 Concrete Waste M2naoemPnt U) PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division 1635 CITY OF Faraday Avenue. APPROVAL (760) 602-4610 CARLSBAD P-29 DATE: 6/9/15 PROJECT NAME: ADDITION PROJECT ID: PLAN CHECK NO: CB151761 SET#: ADDRESS: 2606 JACARANDA AV APN: This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required J Yes N No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: EAJ62@CORNELL.EDU For questions or clarifications on the attached checklist please contact the following reviewer as marked: .•• .... '. . !.'••- • •.•'• •• :•• PLANNING ENGINEERING FIRE PREVENTION.. - 7606024610 7606022750 7606024665 r.•;t. •:-.' '. ••:.:' ' .• .- Chris Sexton Chri.s Glassen Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christorher.Glssen@carlsbadca.gov Greorv.Ryan@carIsbadca.ov Gina Ruiz ValRay Marshall Cindy Wong 760-602-4675 760-602-2741 . 760-602-4662 Gina.Ruiz@carlsbadca.gov ValRay.Marshall@carlsbadca.gov Cynthia.Wonn@carIsbadca.gov Linda Ontiveros Dominic Fieri 760-602-2773. \ 760-602-4664 Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carIsbadcaov Remarks: