HomeMy WebLinkAbout2724 LOKER AVE W; ; CB081232; Permitl' '·
City of Carlsbad
->
09-22-2008
. .1,.635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB081232
Building Inspection Request Line (760) 602-2725
Job Address: 2724 LOKER AV WEST CBAD
Permit Type: Tl Sub Type: INDUST
0 Parcel No: 2090812800 Lot#: Status:
Valuation: $113,435.00 Construction Type: VN Applied:
Occupancy Group: Reference #: Entered By:
Project Title: SENSIENT=-3241 SF Tl-Plan Approved:
(2324 SF WAREHOUSE TO R&D) & (917 SF OFFICE TO Issued:
Applicant:
DESIGN/BUILD TENANT IMP.
SUITE B
9770 CARROLL CENTER RD.
SAN.DIEGO, CA 92126
619-954-9519
Building Permit
Add'I Building Permit Fee
Plan Check
Add') Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD#2 Fee
BTD#3 Fee
Renewal Fee
Add') Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$643.29
$0.00
$418.14
$0.00
$0.00
$23.82
$0.00
$0.00
$154.00
$0.00
$0,00
$0.00
$0.00
$0.00
$0.00
$0.00
~0.00
Inspect Area:
Plan Check#:
Owner:
FENTON HG COMPANY
7577MISSION VALLEY RD
SAN DIEGO CA 92108
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF (3105540)
PFF. (:4305540)
License Tax (3104193)
License Tax (4304193)
Traffi9 Impact Fee (3105541)
Traffic Impact Fee (4305541)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
· Sewer Fee
Redev Parking Fee
Additional Fees
HMP. Fee
TOTAL PERMIT FEES
ISSUED
06/30/2008
RMA
09/22/2008
09/22/2008
$0.00
$0.00
$0.00
$0.00
$1,735.19
$1,601.71
$0.00
$0.00
$167.44
$154.56
$48.00
$20.00
$78.00
$0.00
$146.76
$0.00
$0.00
??
$5,190.91
Total Fees: $5,190.91 Total Payments To Date: $5,190.91 Balance Due: $0.00
B~DING PLANS . __ IN STORAGE Sc.a.r-f\e,{:)
_ATTACHED
FINALAPPROVAL \;a I.a =-
_ Inspector: Date: ~ r "J.B Clearance: ____ _
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to·timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
CityLof Carlsbad
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717 / 2718/ 2719
Fax: 760-602-8558
Building Permit Application
SUITE#/SPACE#/UNIT#
,ZIP
92.loG
Workers' Compensation Declaration:/ hereby affirm under penally ofpeljwy one of the follalling declarations:
TENANT BUSINESS NAME i
Sef'-lSieh
ce:f t-Ti f ,· o h 171 n J 6 3 L . F,
Io o vi
FIREPLACE
YESD #_ N0!21'
AIR CONDITION ING
YES JZI NOD
FIRE SPRINKLERS
YES J<l' NOD
D I have and will maintain a certificate of consent to 1elf-ln111re for workers' qompensalion as provided by Section 3700 of lhe Labor Code, for the performance or Iha work for which this permit is issued.
D I have and will maintain wo a' compen1&tlon, as required by S~lion 3700 of Iha Labor Code, for the performance of the work for which 'this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. . · Pdicy No. 2. 2 4-6 Expiration Dale a I . 1 :Z 2 Q of}
This section need nol be completed if the permit is for one hunci'ed ddlars ($100) or less.
D Certificate of Exemption: I certify Iha! in lhe performance'or the work for which !his permit Is issued, I shall not emµoy any person in any manner so as lo become subjecllo the Workers' Compensation Laws of
Caifomla. WARNING: Failure to secure workers' compenHtlon awful, and shall subject an employer to crtmlnal penalties and civil fines up to one hundred thousand dollars (&100,000), In
addition to the cost of compensation, damag11 aa provided for I action 3706 of a Labor code, Interest and attorney's fee,.
~ CONTRACTOR SIGNATURE '
d
D
Is the apµicanl orfulure buildng.occupanl required lo submit a business_pla • acutely hazardous materials registration form or risk management a
Presley-Tanner Hazardous Substance Account Act? ~y ~ C:J'No
Is the apµicanl or future buildng occupant required to oblai . ermlt,from lhe air pcilulion conlrd district or air quality management dslricl?
Is the facmly to be constructed Within 1,000 feet of lh 0 er boundary of a schod slle? a Yes a No
IF ANY OF THE ANSWERS ARE YES, A FIN ERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE R
EMERGENCY SERVICES AND THE LLUTION CONTROL DISTRICT.
I oortlfythat I have read the application and &tatethatthe above lnfonnatlon Is correct and that the lnfonnatton on the plans Is accurate, I agree to comply with all Cl\yordlnanoos and State laws relating to building construction.
I hereby authorize represenlalive of the Cily of Garlsbad to enter t.pon the above mentioned property for Inspection pwposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AG1\INST ALL LIABILITIES, JUDGMENTS, costs AND EXPENSES WHICH MAYIN ANYWAY ACCRUE AG1\INST SAID CITY IN CONSEQUENCE OF THE GRANTING OFTHIS PERMIT.
OSHA·. An OSHA perrrit Is reqlired for excavafions r:Ner 5a dlep and demdition or construcUon or slructures over 3 stooes in height.
EXPI RATION:.EvS!)' permit issued by the Buildng Offida under the pmvisions of this Code shall exp re by !irritation and become null and void if the buildng or Vvlllk authoozed by such perrrit is not oommenced v.ithin
180 days from the date of such pellTlil orif the buildng or'Mllk authorized by such perrrltis suspenood or abandoned al any lime aller the 'Mllk is oommenced for a period of 180 days (Section 106.4.4 Uniform Buildng Code).
~ APPLICANT'S siGNATURE DATE
I
City of Carlsbad Blqg Inspection Request
For: 11/14/2008
Permit# CB081232 Inspector Assignment: MC
Title: SENSIENT=-3241 SF Tl-.
Description: (2324 SF WAREHOUSE TO R&D) & (917 SF OFFICE TO
OFFICE)
--'---
Type: Tl Sub Type: INDUST
Job Address: 2724 LOKER AV WEST
Suite: -Lot: 0
Location:
APPLICANT DESIGN/Bl,JILD TENANT IMP.
Phone: i234
Inspector:
Owner:
Remarks: COULD HAVE PHIL
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comments
Requested By: ROBERT
Enterec;l 13y: JANEAN
L-~------
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
lns12ection Histo!Y
Date Description Act lnsp. Comments·
11/07/2008 15 Roof/Reroof WC MC
11/07/2008 89 Final Combo PA MC ROOF TOP HVAC EQUIP.
11i05/2008 39 Final Electrical AP RB EMR FOR METER C
10/29/2008 14 Frame/Steel/Bolting/Welding AP MC T-BAR PER ICC REPORT
10/29/2008 24 Rough/Topout WC MC
10/29/2008 34 Rough Electric WC MC
10/29/2008 44 Rough/Ducts/Dampers WC MC
10/28/2008 14 Frame/Steel/Bolting/Welding NR MC T,BAR
10/28/2008 34 Rough Electric AP MC LIGHTING@ T-BAR
10/28/2008 44 Rough/Ducts/Dampers AP MC AIR GRILLES @ T-BAR
10/27/2008 84 Rough Combo co MC NOTICE
10/24/2008 14 Frame/Steel/Bolting/Welding CA PD
10/17/2008 17 Interior Lath/Drywall AP PC
Ci.ty of Carlsbad Bldg Inspection Request
For: 1 t/07 /2008
Permit#. CB081232 Inspector Assignment MC
Title: SENSIENT=-3241 SF Tl-
Description: (23.24 SF WAREHOUSE TO R&D) & (917 SF OFFICE TO
OFFICE)
Type:TI
Job Address:
Sub Type: INDUST
Phone: 6199545234
Suite:
Location:
2724 LOKER AV WEST
Lot 0
APPLICANT DESIGN/BUILD TENANT IMP.
Owner:
Remarks:
Total Time:
Inspector: -----
Requested By: ROBERT
Entered By: CHRISTINE
CD Description Act Comments
15 Roof/Re roof w~_t!:_---,------------c
f'4 ~y . --r"o:t" :H: VA G. ri-!r t..l lp, B~ fuJA~
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
lns12ection Histoiy
Date Description Act lnsp Comments
11/05/2008 39 Final Electrical AP RB EMR FOR METER C
10/29/2008 14 Frame/Steel/Bolting/Welding AP MC T-BAR PER ICC REPORT
10/29/2008 24 Rough/Topout WC MC
10/29/2008 34 Rough Electric WC MC
10/29/2008 44 Rough/Ducts/Dampers WC MC
10/28/2008. 14 Frame/Steel/Bolting/Welding· NR MC T-BAR
10/28/2008 34 Rough Electric AP MC LIGHTING @ T-BAR
10/28/2008 44 Rough/Ducts/Dampers AP MC AIR GRILLES @ T-BAR
10/27/2008 84 Rough Combo co MC NOTICE
10/24/2008 14 Frame/Steel/Bolting/Welding CA PD
10/17/2008 17 Interior Lath/Drywall ·AP .PC
10/16/2008 16 Insulation AP MC DESMISING WALL
10/15/2008 24 Rough/Topout AP MC WASTE&VENT
10/15/2008 63 Walls WC MC
10/14/2008 14 Frame/Steel/Bolting/Welding AP MC DEMISING, PONY & OFFICE WALL FRAMING ONLY
10/14/2008 34 Rough Electric AP MC WALL ELECTRICAL ONLY
10/01/2008 21 Underground/Und~r Floor AP MC WASTE ONLY 3 SINKS & L W/C
09/26/2008 15 Roof/Reroof AP MC . ROOF STRUCTURE FRAMING FOR NEW MECH GEAR (2)
EsGil Corporation
t
In (J'artnersfi.ip witfi. :government for (}Jui(tfing Safety
'DATE: 9/5/08 ~NT
~ JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 08-1232 SET: III
0 PLAN REVIEWER
0 FILE
PROJECT ADDRESS: 2724 Loker Ave West
PROJECT NAME: Senient -TI
D
D
D
D
0
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes, .
---The plans transmitted herewith will sµbstantially comply with the jurisdiction's building codes
when minor deficiencies identifieci.,b~low are resolved and checked by building department staff. _, ~-.4;::;...
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporatioh staff did advise the applicant that the plan check has been completed.
-Person contacted: Telephone#:
Date contact~d: (by: ) Fax #:
Mail Telephone Fax In Person
D REMARKS:
By: Doug Moody
Esgil Corporation
D GA D MB D EJ D PC
·Enclosures:
LOG
9320ChesapeakeDrive,Suite208 + SanDiego,California92123 + (858)560-1468 + Fax(858)560-1576
.EsGH Corporation
In (J?artnersliip witli_ <]overnment for <Bui[aing Safety
DATE: 8/28/08 ~ANT
~ JURISDICT_ION: City of Carlsbad
PLAN CHECK NO.: 08-1232 SET: II
D PLAN REVIEWER
D FILE
PROJECT ADDRESS: 2724 Loker Ave West
PROJECT NAME: Senient -TI
D
D
D
D
D
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans-transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your-information .. The plans are being held at Esgil
Corporation until c9rrected plans are submitted for recheck.
The applicant's copy of the check list is ·enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Design Build Tenant Improvement/ Jaci Edwards
9770 Carroll Center Rd Suite C, San Diego, CA 92125
Esgil Corporation staff ,did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed .
. Person contacted~}~~~E~rds
Date contactect:fY/U't(I (byf'~)
Mail~lephone Faifln Person
REMARKS:
By: Doug Moody
Esgil Corporation
D GA D MB D EJ D PC
Telephone #: 858-549-8455
Fax #:858-530-1779
Enclosures:
8/22/08
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 08-1232
· 8/28/08'
RECHECK CORRECTION LIST
JURISDICTION: City of Carlsbad
.PROJECT ADDRESS: 2724 Loker Ave West
PLAN CHECK NO.: 08-1232
SET: II .
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 8/22/08
REVIEWED BY: Doug Moody
FOREWORD (PLEASE READ):
DATE RECHECK COMPLETED:
8/28/08
This plan review is limited to the technical requirements contained in the Building Code,
Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy
conservation, noise attenuation and disabled access. This plan review is based on regulations
enforced by the Building Department. You may have other corrections based on laws and
ordinances enforced · by the Planning Department, Engineering Department or other
departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
A. Please make all corrections on the original tracings and submit
prints to:
new complete sets of
B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
C._ The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
D. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
DYes DNo
City of Carlsbad 08-1232
; 8/28/08' _
5.
Please make all corrections on the original tracings, as requested in the correction list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department,-1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil Corporation ar:id the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete.
Please provide notes on the plans to show the suspended ceilings in Seismic Design
Categories D, E & F comply with ASCE 7 05 Section 13.5.6.2.1 as fol1011is:
a)
b)
c)
d)
e)
f)
g)
All .ceilings shall use a Heavy Duty T bar grid system.
The width of the perimeter supporting closure angle shall be not less than 2
inches.
In each orthogonal horizontal direction, one end of the ceiling grid shall be
attached to the closure angle.
The other end in each horizontal direction shall have a %" clearance from the wall
and shall rest upon and be free to slide on a closure angle or a listed assembly.
Ceiling areas over 1,000 :ft.2 must have horizontal restraint 'Nires (typically restraint
would consist of four 12 gauge wires splayed 90° to each other and sloped 4 6° to
the horizontal, spaced 12" o.c.).
Ceiling areas over 2500 :ft.2 must have seismic separation joints or full height
partitions.
Ceilings without rigid bracing must have 2" oversize trim rings for.sprinklers and
other ceiling penetrations. The information above was not indicated on the
plans in either note form or as part of the details on sheet D-1.
9. On the plans clearly show the roof insulation locations, thickness, and R values, as per
the energy design. Not indicated on the plans.
11. It is unclear from the plans if the restrooms servicing the tenant improvement are
disabled accessible, please provide a dimensioned restroom plans showing the
restrooms to be accessible compliant. The plans still show the restrooms to be· non-
disabled accessible, plans correct the plans.
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
City of Carlsbad 08-1232
~ 8/28/08'
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
Where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes D No D
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform
the plan review for your,project. If you have any questions regarding these plan review
items, please contact Doug Moody at Esgil Corporation. Thank you.
) .EsGil Corporation
In <Partnersliip witli government for (}Jui{aing Safety
DATE: 7/9/08
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 08-1232
PROJECT ADDRESS: 2724 Loker Ave West
PROJECT NAME: Senient -TI
SET:I
ANT
.
EVIEWER
CJ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with. the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[g] The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant .
contact person.
f:g] The applicant's copy of the check list has been sent to:
Design Build Tenant Improvement/ Jaci Edwards
9770 Carroll Center Rd Suite C, San Diego, CA 92125
D Esgil Corporation staff did not advise the appli?ant that the plan check has been completed.
f:g] Esgil Corporation staff did advise the applicant that the plan check has been completed.
-Person colifactec:l:,1,Japi Edwards Telephone#: 858-549-8455
Date contacted?/'? /tJ 6(b../,ltJ) Fax #: 858-530-1779
Mail~ Telephone Faxv In Person
D .REMARKS:
By: Doug Moody
Esgil Corporation
D GA D MB D EJ. D PC
Enclosures:
7/1/08
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 08-1232
7/9/08 '!.
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
· PLAN CHECK NO.: 08-1232
OCCUPANCY: B/F2?
TYPE OF CONSTRUCTION: VB
ALLOWABLE FLOOR AREA:
SPRINKl.ERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 6/30/08
DATE INITIAL PLAN REVIEW
-COMPLETED: 7 /9/08
FOREWORD (PLEASE READ):
JURISDICTION: City of Carlsbad
USE:. Research & Development
ACTUALAREA: 3241~
STORIES: 1
HEIGHT:
OCCUPANT LOAD: 32
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 7/1/08
_ · PLAN REVIEWER: Doug Moody
This plan review is_ limited to the technical ·requirements contc:1ined in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
required prior to the issuance of a building permit.
_Code section~ cited are based on the 2007 CBC, which adopts the 2006 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2006 Inter-national Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note_ on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad 08-1232
" 7/9'/08 . . ,
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208,. San Diego, CA 92123, (858) 560-1468.
D.eliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. A complete description of the activities and processes that will occur in this
tenant space should be provided. A listing of all hazardous materials should be
included. The materials listing should. be stated in a form that would make
classification in Tables 307.7(1) and 307.7(2) possible. The building official
requires a technical report to identify and develop methods of protection from
hazardous materials. Section 307.7.
2. Please provide the UL listing and· manufacturer's installation information for all
new .equipment to be installed. Show all electrical requirements, plumbing
requirements, exhaust or mechanical requirements, operational weight,
anchorage and seismic restraints if required etc. Section 106.3.3.
3. Clearly indicate on the plans the fume hood exhaust ventilation system
compliance with UMC Chapters 5 & 6.
a) Detail the required make-up air as per UMC, Section 505.3.
b) Detail the exhaust outlet clearances as per UMC, Sections 504.5
---(Environmental) & 506.9 (Product conveying).
c) Clearly show the type of material to be exhausted by each exhaust
system.
d) Clearly show the duct materials are suitable for the intended use. UMC,
Section 506. 1' & 610.1.
e) Clearly show the exhaust duct material and gage used for each duct size.
See UMC Table 6-7.
f) Separate and distin~! systems shall be provided for incompatible
materials. UMC Section 505.1
City of Carlsbad OS~ 1232
'7/9108 '
g) Detail ducts conveying explosives or flammable vapors, fumes or dusts
shall extend directly to the exterior of the building without entering other
spaces. UMC Section 505.1.
h) Detail minimum duct conveying velocities as per UMC Section 505.2 and
Table 5-1 .
. i) Detail duct cleanouts as per UMC Section 506.3.
j) Detail required explosion venting of dust collection systems as per UMC
Section 506.4 & 610.4. ,. . .
k) Detail duct support as per.UMC Sections 506.5 & 610.5.
I) Detail fire protection as per UMC Sections 506.6 & 610.6.
m) Detail clearances from combustibles as per UMC Sections 506.7 & 610.7.
n) Detail protection from physical damage as per UMC Sections 506.8 &
610.8
4. Egress from a room through an 9djoining room (Section 1014.2):
a) Egress shall not pass through kitchens, store rooms (warehouse), closets
or spaces used for similar purposes.
5. Please provide notes on the plans to show the suspended ceilings in Seismic
Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as
follows: .
a) All ceilings shall use a Heavy Duty T-bar grid system.
b) The width of the per,imeter supporting closure angle shall be not less than
2 inches. ·
c) In each orthogonal horizontal direction, one end of the ceiling grid shall be
attached to the closure angle.
d) The other end in each horizontal direction shall have a ¾" clearance from
the wall and shall rest upon and be free to slide on a closure angle or a
listed assembly.
e) Ceiling areas over 1,000 ft.2 must have horizontal restraint wires (typically
restraint would consist of four 12 gauge wires splayed 90° to each other
---·-and sloped 45° to the horizontal, spaced 12" o.c.).
f) Ceiling areas over 2500 ft.2 mL,1st have seismic separation joints or full
height partitions ..
g) Ceilings without rigid bracing mast have 2" oversize trim rings for
sprinklers and other ceiling penetrations.
6. Please clarify the lighting plans it appears occupancy sensors are being installed
(from the new OC symbol) yet all of the L TG forms appear to show what could
be a automatic time switch (is this what is the by-pass switch is for?)
7. Please indicate on the lighting plans the location of the automatic time switch
required by the mandatory measures of the L TG-1-C documents.
City of Carlsbad 08-1232
'7/9/08 · .
8. Please revise the L TG documents to show an automatic time switch or
occupancy sensors and not a by-pass switch.
9. On the plans clearly show the roof insulation locations, thickness, and R-values,
as per the energy design.
10. When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 1134B.2. These
requirements apply as follows:
a) Existing sanitary facilities that seNe the remodeled area must be shown to
comply with all accessibility features.
11. It is unclear from the plans if the restrooms seNicing the tenant improvement are
disabled accessible, please provide a dimensioned restroom plans showing the
restrooms to be accessible compliant.
12. Show that the minimum strike edge distances are provided at the level area on the
side to which a door swings to the new conference, per Section 1133B.2.4.3:
a) ~18" at interior conditions.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
-Yes-CJ No 0
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
City of Carlsbad 08-1232
•7:/9/b8 ' ·
VALUATION AND PLAN CHECK ·FEE
JURISDICTION: City of Carlsbad
PREPARED 13Y.: Doug Moody
PLAN CHECK NO.: 08-1232
DATE: 7/9/08
BUILDING ADDRESS: 2724 Loker Ave West
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB
BUILDING AREA Valuation Reg. VALUE
PORTION (Sq.Ft.) Multiplier Mod.
TJ 3241 34.37
Air Conditioning
Fire Sprinklers .
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit Fee by Ordinance I • I
Plan Check Fee.by Ordinance I~ J
Type of Review: 0 Complete Review D Structural Only
-0 Repetitive Fee--3 Repeats
Comments:
D Other
Hourly I Hour* D .
· Esgil Plan Review Fee
($)
111,393
111,393
$636.571
$413.771
$356.481
Sheet 1 of 1
macvalue.doc
I L..U L.&.. LUV I I IIV UV' IU f\lYI
-····
·-·
-·:,,,,
'\_ ~. ',\ .. , , ...
~ •: ....
~:-..
· ·State{)! California · ··i n~~ CONTRACTORS STATE LICENSE BOARD@·
• ~--.-A~IV~ LICENSE ·: · ~lf'~U0 0 ' • I , • 0
' . . ... · . .
l~ .... i.;.;.., 466554 t.i., INDiV . j
~"" ..... D~SJGN~BU/LD 'iiNANT
·-IMPROVEMENTS . u • • .. •
----... ----·---···-· .. --.... .,.,.,_. "·-------·-·-·-j,,,,•,•-MO........ 0 _ .. · _ ........ "·
'··
0 k\v ~ t,f ~ od:t'wei'J,am6 u.et ba ;oporrad.11) lh• floc.:i;if;ij' w!1hi1 SID cb,ic:' ' : ... . 'Thi;; liCD~ 1$ !'DI l~bkl, 8ftcl shall b& r&IIJl'ne-d fO lliit lle!Jiw,,r • ...... .
·: • 111P,>n d"'"''nd -.itaon ~spc,ndad, N>11olqc:>d1 f>f ll'Mlfldaled ror any 111~. · · · . ·
·This po$! card is vlllicl through Ille a:clllraJ!on dllt, •nly, , · .':
· · · · · ·.·• :·/ .11 ~ drop In 1¥1;rmsJJl)Q);. ··:·:. · · ,.._.:-,~ ··• ·• .. ··
. ·. . ·. · '. :·.'.:,' · Poo~p 91,1;u;,11iood bf; ·, , .. , .. · :· :·
. ' ; . , : , : : . ;Cont~,, Sb\> Uaori,o Bo"1d /
·.~· ..
. ... · Uotnffe·S~alui9
··:,: ...
,,
.,
I• VV"t
CERTIFICATE OF INSURANCE Issue Date: January I. 2008
PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS
Ron Graybeal NO RIGHTS UPON_ THE-CERTIFICATE HOLOE~. THIS CERTIFICATE oqes NOT
Beecher Cartson/JBL&K AMEND. EXTEND OR ALTER THE COVERAGE AFFORDED-BY THE POLICIES BELOW.
220 NW 2nd Avenue. Suite 800 COMPANIES AF.FORDING COVERAGE·
Portland. OR 97209-3951 COMPANY-
INSURED LETTER A National Union Fire Insurance Company of Pittsburg, PA (an AIG Company)
Barrett Business. Services, Inc: COMP,6,NY
8100 NE Parkway,.S\Jite-200 LETTER· B
COMPANY Vancouver. WA 98662 LETTER C And all insureds as defined by a co-emploier contract COMF'ANY incl.: DESIGN BUILD TENANT IMPROVE ENTS LETTER 0 CSLB License No. 466554 COMPANY
9770 CARROLL CENTRE RD STEC
SAN DIEGO, CA 92126-6504 LETTER E
COVERAGES; . . . . . . . .
THl!:rlS TO CERTIFY THAT-HE l'OllCIES OF INSURANCE LISTED BELOW HAile BEEN-ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PER!OO:INDICATED.
NOJWf!"H~TANOl.f)IG A,~Yii:f;QU!REMENT. Tt:R~ OR CONOITlON OF ANY CON'tRAC;'I: OR dT_Hf;R DOCUMEr,ITW!TI-f ~ESPec·(ro Wj-1!¢H THl)fCERTIFJ9ATE MAYSE ISSUED OR MAY PERTAIN, Tl-fE INSURANCEAl'FORPED BY THE POLICIES OESCRIB!:[) HER.EIN 1$ SUBJECHO ALL-rHE: TERMS, EXCLUSIONS, ANO.CdND_ITION ClF SUCH POLICIES. LIIWTS SHOWN.MAY H1WE BEEN REOIJCED BY·PAIO CLAIMS, . co POLICY. EFFECTIVE EXPIRATIQN
LTR_ TYPE OF I_NSURANCE NUMBER DA'ta DATE
GENERAL LIABILITY G~NE~L AGGREGAT!:: SXXX)O(X-LJ COMMERC.1At GENERAL LIABILITY PQIJc:y E:ffeetive · l;xplnil!IOn
:~~~~~:rff~:~isfiN11~~~~~e
$XXX.XXX
. ~CLAll'AS MADE goccUR: Numb« Date Dalt! sxxxxxx D . WNER'S_& CONTRA TQRS PROT: EACH (?CClJRRi:~c.i:t · · · $XXX;l00(
FIRE DAMAGE. ~Any qne ·11r11) . sxxx.xxx
-MEO)CAL EXPENSE (Any one person) SXXX.XXX
(~~~~ COMBINED SINGLE LIMIT , sxxx.xxx
ALL OWNED AUTOS· 1?0011..Y l~JURY(Per person). SXX.X,)00(,
· SCHEDULE AUTO$_ B0011,.Y iNJURY (.ParaccideniJ SXXX.XXX
HJREO AUTOS. PR"OPERTV DAMAGE sxxx,xxx
NON-OWNEOAUTOS COLLISION.DEDUCTIBLE sxxx,xxx
GARAGE LIABILITY .. COtvlPREHENSive beoOCTIE)LE SXXX XXX
EXCESS LIABILITY c:J UMBREUlA FORM. --AGGREGATE
\ t I $XX)(,)()(){ I D OTHER-THAN UMBRELLA FORM
'
WQRKERS'COMP.ENSATION 1$15.000.000 LIMIT
A -~.rs. 1$1 :000,000. I /EACH ACCIDt:N 11
EMPLOY~$' LIABILITY 469-8018 1/112~ 1i1120()9 1s1,ooo.ooo·. TIOtSEASE-POUCY LIMITI
1$1,000000 . I/DISEASE-EACH EMPLOYEE!-
.. OTH_ER
oi:sc~_IPTION-()F·OPERATIONS/LOCATIONSNEHICLE~RE,TRICJION~PECIA!,.ITEM_$
l.lmlt$ shown are above a $5,000,000 self:lnsured retention: _ .
CERTIFICATE HOLDER CANCEL:LATION-Contractors State License Board SHOLiLOANY OF'THE Aaove 01:SCRIBED P.01.JCIES 81; CANCELEO BEFORE THE EXPIRATION O,•,:m
9821 Business P!lfk Drive THEREOF, THE ISSUING COMPAl'/'f-WILL MAIL :IQ DAYS WRITTEN NOTICE. TO-THE -Sacramento, CA 95827 HOLDER NAMED TO.THE LEFT, BUT FAILURE TO M.AJL·SUCH NOTICE SHALL lMP0SE NO OBUGATION
OR.LJABllm'. OF ANY KIND UPON:THE COMPANY. ITS AGENTS, OR REPRESENTATIVES
Aullorlzed Reprl!sentabve A'./.J.,,,e--R Grayb~al, C:Pf;U', ARM
doc: COI-3
February 08, 2008
DESIGN BUILD TENANT IMPROVEMENTS
9770 CARROLL CENTRE RD
STEC
SAN DIEGO, CA 92126-6504
8100 NE Parkway Drive, Suite 200
Vancouver, Washington 98662
Re: B~rrett Business Services, Inc. ("BBSI")
Letter of Self-Insurance for Workers' Compensation Coverage
For DESIGN BUILD TENANT IMPROVEMENTS, CSLB license number 466554
As the named addressee of this Letter, your company's required workers'
compensation coverage is provided through BBSl's state approved Self-Insured
Workers' Compensation Plan. As a party to a co .. employment contract with
88$1, which is effective from 2/1/2008 to 1/31/2009.
California Labor Code §3602 allows DESIGN BUILD TENANT IMPROVEMENTS to
obtain its workers' compensation coverage from 88S1. BBSl's California customers
can also verify BBSl's state certification ~t www.dir.ca.gov./SIP/sip.html: .
next, click on "Rosters''; then click on Private self insured employers; then scroll down to
Barrett (the list is alpha by company name). Additional information is as follows:
Self-Insurance Certification Number:
California:
Oregon:
Washington:
Delaware:
Maryland:
2246
1068
706.116 .
152
11365
360.828.0700
800.494.5669
Fax 360.828.0701
www.horref!business.com
Notice of Termination: BBSI will endeavor to provide 15 days advance notice of the termination of the
workers' compensation coverage to the California Contractor~ State License Board ('CSLB') in the event the
contract between BBSI and DESIGN BUILD TENANT IMPROVEMENTS is terminated.
Other Comments (place an •ix" if applicable):
m Named "Letter Holder'': DESIGN-BUILD TENANT IMPROVEMENTS
D Other:
Additionally, BBSl's self-insured program is further supported by an excess workers'
compensation insurance policy with American International Group (AIG), see accompanying
certificate of insurance.
For additional information, please contact your local BBSI office at (858) 597-0522 .
Very truly yours,
Michael D. Mulholland
Vice President-Finance
BBSI Office: SAN DIEGO
Gooo PEOPLE, Gooo COMPANIES ••. GREAT RESUt.:rsr
doc: LOSI-3
, PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB 08 (). 3 l ·
RESIDENTIAL
RESIDENTIAL ADDfflON MINOR
(<$10,000.00)
PLANNER
,rjQf&:g
DATE 7/8/4'6
c:=IMPRO~
DATE
DATE
·•
PLAZA CAMINO REAL I
CARLSBAD COMPANY STORES
VILLAGE FAIRE
. .
COMPLETE OFFICE BUILDING
I
7/§U§
l l
~
-·
ENGINEERING DEPARTMENT . J'JJq ~
. . FEE c·ALCULATION)'V.ORKSHEE_T vJ!A;0MtM· ~
· D . ./4mate based on uriconfirmed information from applicant.
/. Calculation based on building plancheck plan submittal. .
Address: d-,7J If .. [of e--.kt ~ ~rrnit No. ((3 fJ8 f2: '3j.
Prepared by: -or: Date: __ !3,/4ij . E:hi!eke¢bj,:. -n-Date: 9-/lf/orJ
EDU CALCULATIONS: List !YJ)es_and square fo~tage$ for all use~. ~ ~C-. d(5 ~ ~cc-tcs) . . . ' -. l () Types of Use:~ . . . . Sq. Ft./Omts.______ EDU's: .' ., IA
Types-of Use: ____ "-e:,----· Sq. Ft/Units:. ___ .----'------
,.
ADT CALCULATIONS~ l.:,.ist type~ and square fO.Qtages for all uses. Tsu.-~ ~ ~~c:~sJ. ly'pes of Use: . Sq. Ft./Umts: .
Types of Use:__________ Sq. Ft./Units: _____ _
FEES REQUIRED:
EDU's: ____ _
ADT's: _ __.],__ __
ADT's: _____ _
WITHIN CFO: DYES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) ~ ~ PARK-IN-UEU FEE . PARK AREA & #: ---
FEE/UNIT:.____ X NO. UNITS~ . . · ~
TR~FFIC IMPACT FEE . V .=$ ~ ~
=$ 3J,2~ . / A~T's/UNITS: . 7 X . FEE/ADT: _li_:_
., 3. BRIDGE AN.D THOROUGHFARE FEE (DIST. #1 ~2 __ DIST.#3 __ ) ~
'=$ !Sf/ . . ADT's/UNITS:. 7 X FJ:E/ADT: a{,2
~ F. CILITIES MANAGEMENT FEE ZONE:. __ _
UNIT/SQ.FT.:____ X FEE/SQ.FT./UNIT: __ _
5. SEWER FEE
EDU'$: I /J..
BENEFIT AREA: G
EDU's: , (J_'
SEWER LATERAL ($2,500)
. DRAINAGE FEES PLDA ______ __
ACRES:____ X
~8. POTABLE WATER FEES
UNITS CODE CONNECTION FEE
F:\FEE CALCULATION WORKSHE~:doc
1oq0
X FEE/EDU:~
1~7
X . FEE/EDU:J~
HIGH __ /LOW __
FEE/AC: __ _
METER FEE SDCWAFEE
1 of 2
=$ ,.rt:. ..
=$~
IS,c).1/~
=$)!{~
=$ /2
=$ f1
SDCWAFEE
Rev. 7/14/00
~~
f;-Ol>o (j'.3J-'i) :0 l J
,i
'
EJ)liS -
..,,----
!1
-,;2~J -(Jj ~
~$ 0 .--
¼,(o1~t)z l?
>, ~ >, . ..c ,Q ;;;; ~ ~ -"' "" ~ (.) -~ Q) Q) .c :. :. (.) (.) (.)
C: C: C: "' "' "' a: a: a:
[8]00
[8J D D
[81 D D
~DD
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB081232 Address 2724 Loker Ave. West
Planner :@e-lifm Phone _....(7-=6-=0,_) 6=0=2=---'4 __ 6.1 __ 1 __ . ---'--------
APN: 209-081-28
Type of Project & Use: Tl Net Project Den~ity:_ , , DU/AC
Zoning: P:.M General Plan: Pl Facilities Management Zone: §,
CFD (in/out) #_Date of participation: ____ .Remaining net dev acres: __
Circle One
(For non-residential development Type of land used created by this permit:
_)
Legend: [8J Item Complete
Environmental Review Required:
DATE OF COMPLETION:
D Item Incomplete -Needs your action
YES D NO O TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval: ·
Discretionary Action Required-:; YES O NO D TYPE __
APPROVAURESO. NO. DAtE
PROJECT NO.
OTHER RELATED CASES: __
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __ .
, Coastal Zone Assessment/Compliance , I
Project site located in Coastal Zone? YES O Nb D
CA Coastal Commission-Authority? YES ONO D ,-_. , .. , .,,
If California Coastal Commission Authority: Contact them at --7575 Metropolitan Drive, Suite"f0·3·,
San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? Yl;S D NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
ass·ess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE!)
lnclusionary Housing Fee required: YES D NO 0
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Data Entry Completed? YES D NO D
(A/P/Ds., Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!) ,
'. '~ / ,··
H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08
Site Plan:
DOD
rgJ D D
rgJ D D
\ Provide' a fully dimensio'nal site plan drawn to scale. Show: North arrow, property lines, easements,
existing and proposed structures, streets, . existing street · improvements, right-of-way· wrdth,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes).
Provide legal description of property and assessor's parcel number.
Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES D NO D
2. Project complies: YES D NOD
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
. .
Required_. __ Shown __
Required ____ Shown __ _
Required __ Shown __
Required. __ Shown __
Required ____ Shown __
2. Accessory structure setbacks:
Front: Required __ Shown __
Interior Side: Required _ .. __ .Shc;,wn ____ .
Street Side: Required__:__ Shown _. __
Rear: ·Required_---· Shown __ .. _·
Structure separation: Required _____ · _ Shown __
3. Lot Coverage: Required __ Shown __
4. Height:
5. Parking:
Requi~~--_Shown ___ _
,.O)j} t<L I ~ lR'_
t19w1..X-11-00A,.fl.. ,r ~
A.-i;D ,., . I Spaces .Required ___ .Shown _I _
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Requ1red _ .. __ ··Shown_._. _ ·
:. '
::
•' :.
,:
Additional Comments Correction #1: Please revise parking calculation to account for all square
footage of the building: Parking requirements are based on gross square footage. Correction #2:
Please show square footage of current uses and ·proposed uses. Correction #3: The parking ratio for
biotech research and develo ment is 1 s ace er 300 sf of ross floor area not 3 s aces er 1 000
sf. Correction #4: The north arrow is way off. l\ \,S\&
OKTO ISSUE AND ENTERED·APPROVAL, INTO COMPUTER:·(!_.~ DATE9-/S-~
.. I #
H:\ADMIN\Template\Building Plancheck Review Checklfst.doc Rev 4/08
• ,~. ! :.1
. . ll Carlsbad Fire Department . . '
Plan Review Requirements Category: TI , INDUST
Date ofR.eport:09-15-2008
Name:
Address:
Permit#: CB081232
DESIGN/BUILD TENANT IMP.
SUITEB
9770 CARROLL CENTER RD. ·,
SAN DIEGO, CA 92126
Job Name: SENSIENT=-3241 SF TI-
Job Address: 2724 LOKER AV WEST CBAD
I
Reviewed by: C} j ::tr:n ff
BLDG~ DEPT COPY
' t
adequately conduct a review compliance w1 des and/or standards. Please review
care:fullyall · attached. Please resubmit the necessary plans and/or spec1 nges "clouded",
1--llll"t'F1-·1ce for review and approval.
Conditions:
Cond: CON0002907
[NOT MET]
1,. Sheet A-2 & E-2: Move (2) exit signs in R & D area. Occupants to exit thru open office.·
2. Add Note: "Only main exterior door ot doors are permitted to be equipped witp. key-operated
locking devices from the egress side in accordance with CFC 1008.1.6. All others shall be no
knowledge, single action in accordance with CFC 1008.1.8 and 1008.1.8.4."
Entry: 07/08/2008 By: cwong Action: CO
Cond: CON0003047
[MET] ****NOTE: R & D occupants shall exit through open office ONLY. Exit signs shall reflect
this****
Entry: 09/15/2008 By: cwong Action: AP
Carlsbad Fire D~pat:tment
Plan Review Requirements Category: Tl , INDUST
Date of Rep01t: 07-08-2008
Name:
Address:
DESIGN/BUILD TENANT IMP.
SUITE B
9770 CARROLL CENTER RD.
SAN DIEGO, CA 92126
Permit#: CB081232
Job Name: SENSIENT=-3241 SF TI-
Job Address: 2724 LOKER AV WEST CBAD
BLDG. DEPT COPY
CTN_liOMRf,E:t:.E3 The item you have su,bmitted for review is incomplete. At this time, this office cannot
adequately conduct a review to detennihe compliance with the applicable codes and/or standards. Please review
carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval.
Conditions: .
Cond: CON0002907
[NOT MET]
. 1. Sheet A-2 & E-2: Move (2) exit signs in_R & D area. Occupants to exit thru open office.
2. Add Note: "Only main exterior door er doors are permitted to be equipped with key-operated
locking devices from the egress side in accordance with CFC 1008.1.6. All others shall be no
knowledge, single action in accordance with CFC 1008.LS and 1008.1.8.4."
Entry: 07/08/2008 By: cwong ~~CI~
,.
1-s:-_ Se.-:;isient Haz Matl Inventory 7/31/2008
All hazardous materials and waste on site meets the following criteria: NOT Radioactive and all stored at ambient temperature and pressure
All material is measured in LB with the largest storage container for useable material being 40 LB ( 5 GA pail)
Waste material maximum storage will be 240 LB (30 GA drum) for liquids and 300 LB Fiber tote for solid NON-RCRA waste
Haz Matt Type Physical State FED Hazard Categories
Pressure Acute Chronic
Chemical Name CAS# Pure 'Mix Vl(aste Solid Liquid Gas Flammable Reactive Release Health Health
Dyes, Dry Various . X X X X
Dyes, l,.iquid Various X X X X
Inks, Water based NA X X X
ALCOHOLS
Diacetone _Alcohol 123-42-2 X X UN1148 X
Butyl Alcohol 71-36-3 X X UN1120 X
' Propanol 70657-70-4 X X UN1987 X
lsopropyl Alcohol 67-63-0 X X UN1219 X
Ethyl Alcohol 64-17-5 X X UN1987 X
N-Butanol 71-36-3 X X UN1120 X
Cychlohexanone 108-94-1 X X UN1915 X
GLYCOLS
Ethylene Glycol 107-21-1 X X
Diethylene Glycol_ 111-46-6 X X
Carbowax Polyethylene Glycol 25322-68-3 X X X
Glycerine 56-81-5 X X
-
-
Storage
Container (see
below)
CNS
CNS
,CN1
GA
CN1
CN1
GA
CN1
CN1
<:;,A
GA
FC: FLAMMABLE CABINET CN1 MET AL CAN 8 LB DM30 DRUM 240 LB CY CYLINDER
FH: FUME HOOD CNS METAL CAN 40 LB DMF30 DRUM FLAMMABLE 240 LB
(flammble cabinet under fume hood) GA GALLON 8 LB PB PLASTIC BOTTLE
CC: CORROSIVE CABINET PL5 PAIL40 LB GB GLASS BOTTLE
~
1 of2
Chemical Locations
Maximum Approx
Daily Yearly Days on
Amount Amount Site Daily Use Bulk
365 m~in lab
365 rriain lab
365 main lab
5LB 200LB 365 FH-1 FC-1
2LB 160 LB 365 FH-1 FC-1
.25LB 10 LB 365 FH-1 FC-1 ~
5 LB 200 LB, 365 FH-1 . FC-1 I~
2LB 100 LB 365 FH-5 FC-1 '
lA
2 LB 100 LB 365 .FH-5 FC'-1 .L p-,..
1 LB 50 LB 365 FH-4 FC-2 ' -t)
I'--
3 LB 200 LB 365 FH-2 FC-3
3LB 200 LB 365 FH-2 , FC-3
1 LB 100 LB 365 FH-2 FC-3
2 LB 100 LB 365 FH-4 FC-3
(?~ D ,:y-I 2-32-
'i S.6ilsient Haz Matl Inventory 7/31/2008
All hazardous materials and waste on site meets the following criteria: NOT Radioactive and all stored at ambient temperature and pressure
All material is measured in LB with the largest storage container for useable material being 40 LB (5 GA pail)
Waste material maximum storage will be 240 LB (30 GA drum) for liquids and 300 LB Fiber tote for solid NON-RCRA waste
Haz Matl Type Physical State FED Hazard Categories
Pressure Acute Chronic
Ghemical Name CAS# Pure Mix Waste Solid . Liquid Gas Flammable Reactive Release Health Health
GLYCOL ETHERS
Dowanal PM Glycol Ether 107-98-2 X X UN3902 X X
SOLVENTS
Acetone 67-64-1 X X UN1090 X
Exxate 600 Solvent propdatary X X UN1194 X
Defoamers 8052-41-3 X X UN1993 X X
l
..
Storage
Container (see
below)
CN1
GA
CN1
CN1
FC: FLAMMABLE CABINET CN1 MET AL CAN 8 LB DM30 DRUM 240 LB CY CYLINDER
FH: FUME HOOD CNS METAL CAN 40 LB DMF30 DRUM FLAMMABLE 240 LB
(flammble cabinet under fume hood) GA GALLON 8 LB PB PLASTIC BOTTLE
CC: CORROSIVE CABINET PLS PAIL40 LB GB GLASS BOTTLE
2 of2
Chemical Locations
Maximum Approx
l)aily Yearly Days on
Amount Amount Site Daily Use Bulk
5LB 250 LB 365 FH-2 FC-2
16 LB · 400 LB 365 FH-5 FC-4
1 LB S0LB 365 FH-5 FC--4
2 LB . 200 LB 365 FH-3 FC-3
/j /J I\ v I ~'2 / .,-., -. . -
TITLE 24 REPORT
Title 24 Report for:
Sensient Technologies
2724 Loker Ave West
Carlsbad, CA 92054
Project Designer:
Design Build Tenant Improvements
9770 Carroll Center Road Suite C
San Diego, CA 92126
(858) 549-8455
·Report Prepared By:
Will Gander
Design Build Tenant Improvements
9770 Carroll Center Rd.
San Diego, CA 92126
(858) 549-8455
Job Number:
4339H
Date:
6/27/2008
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the ca·lifornia Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC -www.energysoft.com.
Ene_rgyPro 4.3 by E:nergySoff JobNumber. 4339H User Number: 6328
. .
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Nonresidential Performance Title 24 Forms 3
Form ENV-MM Envelope Mandatory Measures 14
. Form L TG-MM Lighting Mandatory Measures 15
Form MECH-MM Mechanical Mandatory Measures 16
EnergyPro 4.3 by EnergySoft Job,Number: 4339H User Number: 6328
IPERFORMANCE C~R"J:IFICATE OF COMPLIANCE Part 1 of 3 PERF-11
· PROJECT NAME DATE
Sensient TechnoloQies 6/27/2008
PROJECT ADDRESS
2724 Loker Ave West Carlsbad
PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Building Permit #
Design Build Tenant Improvements (858) 549-8455
DOCUMENTATION AUTHOR TELEPHONE Checked by/Date
Design Build Tenant Improvements (858) 549-8455 Enforcement Agency Use
GENE~L INFORMATION
DATE-OF PLANS IBUILDING CONDITIONED FLOOR AREA /CLIMATE ZONE?
6/11/08 2,324 Sq.Ft.
BUILDING TYPE [Kl NONRESIDENTIAL 0 HIGH RISE RESIDENTIAL D HOTEUMOTEL GUEST ROOM
· PHASE OF CONSTRUCTION D NEW CONSTRUCTION D ADDITION D EXISTING+ ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code·of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation prepar!)r hereby certifies that the docum.entation· is accurate and ca lete.
DOCUMENTATION AUTHOR SIGNATURE
Will Gander
The Principal Designer hereby certifys th~t the proposed building design represe t d in this set of construction documents is
consistent with the other compliance forms and worksheets, with the specification nd with any other calculations submitted with this
permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 ofTitle 24, Part 6.
ENV. J..,TG. MECH.
D D
D D
D
D
1. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect.
2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
3. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures /1'1 -,5 1---'----=--------------------l
Required Forms ENV-1
PRINCIPAL ENVELOPE DESIGNER -NAM~ UC.NO.
Desi n Build Tenant Im rovements '-lb(o55
LIGHTING COMPLIANCE
PRINCIPAL LIGHTING DESIGNER-NAME UC. NO.
~-~~~D~e~si~n~B~u~ild~E~le~c~tr~ic~ __ -1,_--1;,u.....e;~~_,,;;.:;~~-==;;;_...L......!.!'.:4C655i_..._~-i..-~
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measyres 1----------------------l
Required Forms MECH-1 MECH-2 MECH-3 MECH-5
PRINCIPAL MECHANICAL DESIGNER· NAME ·
Desi n Build HVAC
Run Initiation Time: 06/27/08 12:49:53
EnergyPro 4.3 by EpergySoft User Number.. 6328
UC. NO. DATE
~~\S4 G,--z., 1--ob()
Run Code: 1214596193
. Job Number. 4339H Page:3 of 17
I PERFO~MANCE Cf:=RT,IFICATE OF COMPLIANCE -Part 2 of 3
PROJECT NAME
_ Sensient Technolo ies
ANNUAL TDV ENERGY USE SUMMARY kBtu/s
ENERGY COMPONENT
Space Heating
Space Cooling
Indoor Fans
Heat Rejection
Pumps & Misc.
Domestic Hot Water
Lighting
Receptacle
Process
TOTALS:
Standard
Design
3.54
178.97
87.76
Q.00
0.00
0.00
72,80
83.94
0.00
427.01
Percent better than Standard:
GENERAL INFORMATION
Proposed
Design
0.37
89.58
56.93
0.00
0.00
0.00
65.52
83.94
0.00
296.34
Compliance
Margin
3.17
89.39
30.83
0.00
0.00
0.00
7.28
0.00
0.00
-130.67
30.6% ( 30.6% excluding process)
· BUILDING COMPLIES
(N) 0 deo Conditioned Floor Area
1 Unconditioned Floor Area
2 Cqnditioned Footprint Area
2,324 sqft.
0 sqft.
2,324 sqft.
·suilding Orientation
Number of Stories
Number of Systems
Number of Zones 1 Fuel Type Natural Gas
Front Elevation
Left Elevation
Rear Elevation
Right Elevation
Roof
Total
Orientation
<N
(E
(S
(W
Standard
Lighting Power Density 1.200 W/sqft.
Prescriptive Env. Heat Loss f----4--'--'6"'-16 Btuth
Prescriptive Env. Heaf Gain 20,488 Btuth-F
Remarks:
Gross Area
0 sqft.
-0 sqft.
0 sqft.
640 sqft.
640 sqft.
2,3241sqft.
Proposed
,__ __ 1_.0_8......,0 W/sqft.
f--~-6'--'4--l7 Btu/h
25,128 Btu/h-F
Glazino Area Glazino Ratio
0 sqft. 0.0%
0 sqft. 0.0%
0 sqft. 0.0%
24 sqft. 3.8%
24 sqft. 3.8%
olsqft. 0.0%1
Run Initiation Time: 06/27/08 12:49:53 Run Code: 1214596193
EnergyPro 4.3 by EnergySoft User Number: 6328 Job Number: 4339H
DATE
PERF-1
6/27/2008
Page:4 of 17
-!PERFORMANCE CERT,FICATE OF COMPLIANCE Part·3 of 3-PERF-11
rROJECT NAME . .
Sensient Technologies
!DATE 6/27/2008
ZONE INFORMATION
. -Floor Inst. Ctrl. Allowed LPD Proc.
Area LPD Credits .Area Tailored Loads
System Name Zone Narpe Occupancy Type (sqft.) (W/sf)1 (W/sf)2 (W/sf)3 (W/sf)4 (W/sf)
HP-4 & 5 Research & Dev. Office 2,324 1.08(
-
.
Notes: 1. See LTG-2-C 2.SeeLTG-4-C 3. See L TG-5-C 4. See L TG-6-C Items above require special documentation (items marked with asterisk, see LTG-2 -C by others) (by others)
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
The local enforcement agenc;y should pay special attention to the items specified in this checklist. These items require special written justification
and documentation, and special verification to be used with-the performance approach. The local enforcement agency determines the adequacy of
the justification, arid may reject a building or design that-otherwise complies based on the adequacy of the special justification and documentation
submitted. ·
The HVAC System "604BPX036" is desionated-as 3 Phase, or is Exempted from the NAECA 13 SEER requirement.
The Roof "Roof'-has been designated as an alteration, however the Roof Surface is NOT being replaced.
'
The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant.
Authorized Signature or Stamp
Run Initiation Time: 06/27/08 12:49:53 Run Code: 1214596193
EnergyPro 4.3 by EnergySoft ·user !'{umber: 6328 Job Number: 4339H Page:5 of 17
I
!CERTIFICATE :OF GOMPLIANCE ENV-1-Cj
PROJECT-NAME DATE
Sensient T echnolo ies 6/27/2008
!OPAQUE SURFACES
Surface Insulation Act. Cond~ Joint Appendix # Type Area U-Fac. Cav. Cont. Azm. Tilt Status IV Reference Location I Comments
1 Wall 61E .0.820 None R-0.0 270 90 Existina 13-DS Research & Dev.
2. Roof 2,324 0.048 R-19 R-0.0 0 0 Altered 01-A14 (E=01-A11) Research & Dev.
.. • N, E, A, R (New, E>asting, Altered, Removed) I FENESTRATION SURFACES
D More than or equal to 10,000 sq.ft. of site-built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U-factors from
Standards Table 116-A and B Certificate shall be filed in the contractor's project office during construction and in the building manager's office after construction
Ac"t. Cond. ·
# Tvoe Area U-Fac.1 _SHGC 2 Azm. Stat. Glazinq Tvpe
1 Window Riaht (W) . 24 1.280 116-A 0:67 116-B 270 Existino SinaleMetalTinted
(1l U-factor Type: 116~A Default Table from Standards, Table Nl-1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
Window Overhang
# Exterior Shade Type SHGC Hgt. Wd, Len. Hat. LExt.RExt.
1 None 0.76
..
""
! MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
Left Fin
Dist. Len. Hat.
Location/
Comments
Research & Dev.
Right Fin
Dist. Len. Hat.
D The proposed building is in climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general
lighting of at Jeasf0.5 W/ft2. Se'!' Section 143(c). If this box is checked, ENV-4-C must be filled out. when submitting under the Prescriptive Compliance Approach.
Run Initiation Time: 06/27/08 12:49:53 Run Code: 1214596193
EnergyPro 4,3 by _EnergySoft User Number: 6328 Job Number: 4339H Page:6 of 17
fCERTIFICATE OF CO~PLIANCE (Part 1 of 3) L TG-1-CI
PROJECT NAME DATE
Sensient Technolo ies 6/27/2008
!INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG-2-C)
PORTABLE LIGHTING (From LTG-3-C)
LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG-4-C)
CONDITIONED.SPACE ADJUSTED INSTALLED LIGHTING POWER
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG-2-C)
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG-4-C)
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER
ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES
0 ·COMPLETE BUILDING METHOD (From L TG-5-C)
0 AREA CATEGORY METHOD.(From LTG-5-C)
0 TAILORED METHOD (From L TG-5.,C) ALLOWED LIGHTING PQWER
!AL TERNA TE COMPLIANCE
IB) PERFORMANCE METHOD
0 COMM MON LIGHTING SYSTEM (From L TG-8-C)
!ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES (From LTG-5-C)
!MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS
CONTROL LOCATION
(Room#)
CONTROL
IDENTIFICATION
--. CONTROL TYPE
(Auto Time Switch, Dimming, etc.)
NOTES TO FIELD • For Buildina Department Use "Onlv
SPACE CONTROLLED
Run Initiation Time: 06/27/08 12:49:53 Run Code: 1214596193
EnergyPro 4.3 by EnergySoft User Number: 6328 Job Number: 4339H
INSTALLED
WATTS
2 511
0
0
2 511
0
0
0
ALLOWED
WATTS
2,511
0
Check if NOTE TO
Daylighting FIELD
Page:7 of 17
lcERT1F1cATE oF coMPLIANCE
I
(Part 3 of 3) L TG-1-Cj
...
PROJECT NAME IDATE Sensient Technolooies 6/27/2008
Designer:
This form is to be used by the _designer and attached to the plans. Listed below are all the acceptance
tests for lighting systems. The designer is required to check the boxes by all acceptance tests that
apply and list all equipment that require an acceptance test. If all equipment of a certain type requires
a test, list the equipment description and the number of systems to be tested in parentheses. The NJ
number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the
test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design
professional or an agent selected by the owner). Since this form will be part of the plans, completion
of this section will allow the responsible party to budget for the scope of work appropriately.
Building Departments:
Before an occupancy permit is granted for a newly constructed building or space, or a new lighting
system system serving a building or space-is operated for normal use, all control devices serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
In addition a Certificate of Acceptance, L TG-1--A, Forms shall be submitted to the building department
that:
A. Certifies plans, specifications, installation certificates, and operating and maintenance
information meet the requirements of§ 10-103(b) and Title 24 Part 6 .
. .
Test Descriotion I Test Performed Bv:
D LTG-2-A: Lighting Control Acceptance Document
-Occupancy Sensor Acceptance
-Manual Daylight Controls Acceptance
-Automatic Time Switch Control. Acceptance
Equipment requiring acceptance testing
D LTG-3-A: Automatic Daylighting Controls Acceptance Document
Equ!pment requiring acceptance testing
Run Initiation Time: 06/27/08 12:49:53 Run Code: 1214596193
EnergyPro 4.3 by EnergySoft User Number. 6328 Job Number: 4339H Page:8 of 17
]CERTIFICATE OF COM.PLIANCE MECH-1-CI·
PROJECT NAME DATE
Sensient Technolo ies 6/27/2008
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the -boxes by all acceptance tests that ;;ipply and list all equipment that requires an .acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ-number designates the Section in the Appendix of the Nonresidential
ACM Manual-that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent
selected by th_e owner). Since this form will be part of the plans, completion of this section will_ allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is-granted for a newly constructed building or space, or a new space-conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance:
In addition a Certificate of Acceptance, MECH-1-AForm shall be submitted to the building department that certifies plans, specifications, installation
certificates, and ooeratina and maintenance information meet the reauirements of Section 10-103(b) and Title 24 Part 6.
STATEMENT OF COMPLIANCE
0 MECH-2-A: Ventilation System Acceptance Document
-Variable Air Volume Systems Outdoor Air Acceptance
-Constant Air Volume Systems Outdoor Air Acceptance
Equipment requiring acceptance testing
Test required on all New systems both New Construr:tion and Retrofit. .
0 MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
D MECH-4-A: Air~Side Economizer Acceptance Document
);:quipment requiring acceptance testing
Test required on all New systems both New Construction and-Retrofit. -Units with ec_onomizers that are installed at the factory and certified with the
commission do not require equipment testing but do require.construr:tion inspection.
0 MECH-5-A: Air Distribution Acceptance DoctJment
Equipment requiring acceptance testing
.
This test required If the unit serves 5,000 ft2 of space or Jess and 25% or more otthe ducts are in nonconditioned or semicondilioned space like an
attic, New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or
replace_ the packaged unit._
.D MECH-6-A: Demand Control Ventilation Acceptance Document
Equipment r~cjuiring acceptance testing
All new DCV controls installed on new or existing packaged systems must be tested.
D MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VAV fan volume controls installed on new .or existing systems must be tested
0 MECH-8-A: -Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled ·and hot water systems.
-Automatic· Isolation Controls Applies to new t1oilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chilled.and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr.
-Water-loop Heat Pump Controls
Applies to all new waterfoop heat pump systems where the combined loop pumps are greatet than 5 hp.
-Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment requiring acceptance testing
EnergyPro 4.3 by EnergySoft User Number. 6328 Job Number: 4339H Page:9 of 17
!INDOOR LIGHTING. SC,HEDULE
PROJECT NAME
Sensient Technolo ies
!INSTALLED LIGHTING POWER FOR CONDITIONED SPACES
(Part 1 of 2) LTG-2-CI
DATE
6/27/2008
luminaire Lamps/Ball~sts Installed Watts
·c D
rrz C lll c
~!;;"· 333 ~--g g 'O 3 CD 'O -·"C -, <D CD 0 Name Type Description -.-
(3) 4 ft Fluorescent T8 Rapid Start Elec 3 F32T8
..
. .
Run Initiation Time: 06/2770812:49:53
E F G H I
rCDZ r r
0 C z 3 !1b3 C :E 3 l;-o i CD 0 C s·~ c, 2.'0 0) iii'm s·o 3 3 CD -::, CD -E.O 0) -0" "'O.., en m -CD 0) ... --·"C .., -· C/J :::s @· ~ CD ro o ro -.-Yes No C/J
32 1.0 93.0 X 27
PAGE TOTAL
BUILDING TOTAL (sum of all pages)
PORTABLE LIGHTING (From LTG-3-C)
CONTROL CREDIT (From L TG-4-C)
ADJUSTED ACTUAL WATTS
Run Code: 1214596193
J
~:E:i G'l !!l. x~~
.::;ci>[
2 511
2,511!
2,511/
ol
ol
2.511!
EnergyPro 4.3 by EnergySoft User Number: 6328 Job Number: 4339H Page: 10 of 17
jAIR SYSTEM REQlJIRl;MENTS Part 1 of 2 MECH-2-Cj
PROJECT NAME
Sensient Tec:hnolo ies
DATE
6/27/2008
iSYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
MANDATORY MEASURES
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated.Sensible Cooling Capac_ity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor'Locatio11
Supply Pressur,e Reset (DOC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
· Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance3
T-24
Section
. 112(a)
112fa\
112(b)
112(c), 115(a)
121{b)
121(b)
121(c)
121(c)
121fc) 122fe)
122(e)
122(f)
122(9)
123
124
144 (a.& b)
144(a&b)
144 (a & b)
144(a&bl
144 (c)
144 (c) .
144 (c) '.
144 (d)
144 (e)
144 (f)
144 (f)
144 (k)
AIR SYSTEMS, Central or Single Zone
HP-4&5
2
Reference on Plans or Specification 1
8.00 HSPF
13.0 SEER/ 11.0 EER
Yes
n/a
Yes
349 cfm
No
No
Proarammable Switch
No Setback Required
Auto
nla
R-8.0
n/a
70,096 btuh
n!a
55,779 btuh
Constant Volume
Yes
No
.No Economizer
ConstantTemp
Constant Temp
No
1: For each central and single z~ne air systems ( or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required·features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put-in reference ot plans and specificatons per footnote 1.
3: Enter Yes if System.is: Constant Volume, Single Zone; Serves.: 5,000 sqft; Has> 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF-1 for performance method duct sealing.requirements.
NOTES TO FIELD -For Buildina Deoartment Use Onlv
Run Initiation Time: 06/27/08 12:49:53 Run Code: 1214596193
EnergyPro 4.3 by·EnergySoft User Number: 632.8 Jo_b !'Jumber: 4339H Page:11 of 17
jMECHANICAL VENTIL~TION MECH-3-CI
PROJECT NAME DATE
Sensient Technolo ies 6/27/2008
PRESCRIPTIVE REHEAT
MECHANICAL VENTILATION Section 121lb 2) LIMITATION (Section 144(d))
AREA.BASIS OCCUPANCY BASIS VAVMINIMUM
A B C D E .F. G H I J K L M N
Nl:; ;,;O 0 CJ) C" Cl) --1 (") .c -C"S: z '< s: ;o < g~ (") 0 Q. CJ) !!!. ... ;_>g Iii (") .,, C: .,, m ~ 5· os:m (")Cl) 0 "II [D ... C: s: Cl) IQ Ill
[D'< :i' Cl) 3 Cl) 'ti(") 0 Ill Q (")Cl> 0 ~ >< w3 111 .... ::, ::,
CJ) ... C. ... 'ti "II >< ~(") 0 C" ii! Cl) "II >< 0 (") -n am "TIC/)"" O::, >< -g s: Cl)
"II Cl) -· Cl)~ s: Ji!: 0 -.s: ... >< 0 s: :,:.cEi' s: C: 0 Cl) 0 Oen 0 it -m!::t. "II nm~-"II C: "II C>!a,< 'ti Cl) .c . 5· 5· ... -0 ::, --gs: _,::, •.i,. (") :c: ..., ZONE/SYSTEM ::l 0 0 -)> ... 'ti!!!. rl' ..... > 0 .... a '<'§ "II• =r .... S::-> =·
Research & Dev. 2,32L 0.15 349 349 349
HP-4.&5 Total 349 349
..
C Minimum ventilation rate per Section 121, Table 121-A
E Based on fixed seat or the Qreater of the exoected number ofoccupants and 50% of the CBC occupant load for egress purposes for so aces without fixed seatino.
H, · Required Ventilation Air (REQ'D V.A) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column Dor G).
I Must be oreaterthan or equal to H, or use.Transfer Air (column N) toinake up the difference.
J Design fan supply cfm (Fan CFM) x 30%; or
K Condition area (ft. sq.) x 04 cfm/ft. sq.; or
,L Maximum of Columns H, J, K, or 300 cfm
M This must be'less than or eaual to Column Land greater that or equ·aI to the suni of Columns H + N.
N Transfer.air must be provided where the Required Ventilation Air (coiumn I) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal
to the difference between the Required Ventila_tion Air (column I) and the Design Minimum Air (column M), column H -M.
EnergyPro 4.3 by EnergySoft User Number: 6328 Job Number: 4339H Page: 12 of 17
!MECHANICAL EQUIPMENT DETAILS. Part 1 of 2
I . MECH-s-cl
PROJECT NAME
DATE 6/27/2008 I Sensient Techrioloaies
CHILLER AND TOWER SUMMARY
PUMPS
Tot. .. Motor Drive Pump
Eql!ipment Name Equipment Type Qty. Efficiency Tons Qty GPM BHP Eff. Eff. Control
DHW / BOILER SUMMARY
Energy Standby TANKINSUL.
Rated Vol. Condition Factor Loss or Ext.
System Name System Type Distribution Type Qty Input (Gals.) Status or RE Pilot R-Val.
MULTI-FAMILY CENTRAL WATER HEATING DETAILS
Hot Water Pump Hot Water Piping Length (ft)
Control # HP Tvne In Plenum Outside Buried Add 1/2" Insulation .
CENTRAL SYSTEM RATINGS
HEATING. COOLING
Aux. Condition
Svstem Name Svstem Tvoe Qtv Outbut · kW Eff. Cutout Efficiencv Status Economizer Type
604BPX036 Packaged DX 2 36,000 2.2 8.00HSPF 36,000 13.0 SEER/ 11.0 EER New No Economi?:er
CENTRAL SYSTEM FAN SUMMARY
SUPPLY FAN RETURN FAN
Motor Drive Motor Drive
Svstem Name FanTvoe Motor Location CFM BHP Eff. Eff. CFM BHP Eff. Eff.
604BPX036 Constant Volume Draw-Through 1,200 0.75 77.0% 97.0% none
Run Initiation Time: .06/27/08 12:49:53 Run Code: 1214596193
EnergyPro 4.3. by EnergySoft User Number:·6328 Job Number: 4339H Page: 13 of 17
fENVELOPE MAND~ TO.RY MEASURES ENV-MMI
PROJECT NAME DATE
· Sensient Technolo ies 6/27/2008
·DESCRIPTION Designer Enforcement
[X] § 118(a) lnstalied Insulating Material shall have been certified by the manufacturer to comply
with the California Quality Standards for insulating material, Title 20, Chapter 4, Article
3.
[X] § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
D § 117(a} All Exterior Joints and openings in the building that are observable sources of air
l~akage shall be caulked, gasketed, weatherstripped or otherwise sealed.
D § 116(b) Site-Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors and
fire doors).
D § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration.products must'be labeled for U-value according to NFRC procedures.
[X] § 118(e) Demising Walls in Nonresidential Buildings:
The opaque portions of framed demising walls in-nonresidential buildings shall have
insulation with an installed·R-value of no less than R-13 between framing members.
EnergyPro By·EnergySoft User-Number: User Job Number: 4339H Page:14 of 17
·ILIGHTING.MANDATORY MEASURES
PROJECT NAME
Sensient Technolo ies
DESCRIPTION
IX] §131{d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic
c~ntrol to shot off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automatically shutting off the lighting.
IZJ §131 (d)2Override for Building Lighting Shut-off: T~e automatic building shut-off system is
provided with a manual, accessible override switch in sight of the lights. The area
of override is not to exceed 5,000 square feet.
IZJ §119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified arid installed as directed by the
manufacturer.
[ZJ §111
[ZJ §132
Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for
the project are certified and listed in the Djrectory::--A11 installed fixtures shall be
certified.
Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three
lamp fluorescent fixtures are tandem wired with two lamp ballasts where required
by Standards Section 132; or all one and three lamp fluorescent fixtures are
specified with electronic high-frequency ballasts and are exempt from tandem
wiring requirements.
[Z] §131(a) Individual Room/Area Controls: Each room and area in this building is equipped
with a separate switch or-occupancy sensor device for each area with floor-to-
ceiling walls.
[Z] ~131{b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
. controlled with bi-level switching for uniform.reduction of lighting within the room.
[Z] §131 (c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 sq~are feet and that allow for the effective use of daylight in the area shall
have 50% of the lamps in each daylit area controlled· IJy a separate switch; or the
effective use of daylight cannot be accomplished because the windows are
continuously shad.ed by a. building on the adjacent lot. Diagram of shading during
different times of the year is included on plans.
Ix] §131{e) l?isplay Lighting. Display li!Jhting shall be separately switched on circuits that
are 20 amps or less.
EnergyPro 4.3 by EnergySoft · User Number: 6328 Job Number: 4339H
LTG-MMI
DATE
6/27/2008
Designer Enforcement
Page:15 of 17
fMECHANICAL MA~DAJORY MEASURES
PROJECT NAME
Sensient Technolo ies
DESCRIPTION
Equipment and Systems Efficiencies
[x] §111 Any appliance for which there is. a California standard established in the Applianc:e
Efficiency Regulations will comply wjth the applicable standard.
D § 115(a) Fan type central furnaces shall not have a pilot light.
[X] § 123 Piping, except that conveying fluids .at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated in accordance with
Standards Section 123,
[Z] § 124 Air handling duct systems shall be -installed and insulated in compliance with
Sections 601,602, 603, 604,and 605 of the 20'01 CMC Standards.
Controls
§ 122(e) Each space conditioning system shall be installed with one of the following:
/
D § 122(e)1A Each space conditioning system.serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the requirements
of Section 112 (d)) shall be installed with an automatic time switch with an
acc_essible manual override that allows operation of the system during off-hours for
.up to4 hours. The time switch shall be capabie of programming different
schedules for weekdays and weekends and have program backup capabilities that
prevent the loss of the device's program and time setting for at least 1 O hours if
· power is interrupted; or
D § 122(e)1B An occupc1ncy sensor to control the operatin_g period of the system; or
D § 122(e)1C A 4-hour timer that can be manually operated·to control the operating period of the
.system.
D § 122(e)2 Each space conditioning system shall be installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup cooling thermostat setpoint.
D § 122(g) Each space conditioning system serving multiple zones with a combined
conditioned f19or are<! more than 25,000 square feet shall be provided with isolation
zones. Each zone: shall not exceed 25,000 square feet; shall be provided with
isolation devices, ~uch as valves or dampers, that allow the supply of heating or
cooling to be setback or shut off independently of other isolation areas; and shall
be controlled by a time control device as described above.
[x] § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat
that responds to temperature within the zone. Where used to C0!1trol heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the control
shall be adjustabie up to-85 degrees F or higher. Where used for both heating and
cooling, the control shall be capable of providing a deadband of at least 5 degrees
F within which the supply of heating and cooling is shut ·off or reduced to a
minimum.
[X] § 122(c) Thermostats shall have ·numeric setpoints in degrees Fahrenheit (F) and adjustable
setpoint stops accessible only to authorized personnel.
D § 112(b) Heat pumps shall be installed with controls to prevent electric resistance
supplementary heater operation when the heating load can be met by the heat
pl.imp alone.
EnergyPro By EnergySoft User Number. User Job Number: 4339H
Part 1 of 2 MECH-MM!
(
(
DATE
6/27/2008
Designer Enforcement
I~
(J!J'~
(Dv'---
~k -
~r--
'
Page: 16 of 17
fMECHANICAL MA~ DAro_RY-MEASURES Part 2 of 2 MECH-MMj
PROJECT NAME DATE
Sensient Technolo ies 6/27/2008
Description Designer Enforcement
Ventilation
[:gJ § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at (~)\l~ the ventilation rates as specified on these plans.
D § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be
provid_ed on the outside air intakes and discharges of all space conditioning and
exhaust systems.
D § 122(f) All gravity ventilating systems shall be provided with ·automatic or readily accessible
manually operated dampers in all openings to the outside, except for combustion air
openings.
D § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National
Environmental Balancing B~reau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council {AABC) National Standards (1989); or
D § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measure!! and certified by the
installing licensed C-20 mechanical contractor and certified by (1) the design,
mechanical engineer, (2) thfl installing Iicenced C-20 mechanical contractor, or (3) the
person with overall responsibility for the design of the ventilation system; or
[Z] § 121(f)3 Outside Air Measurerpent: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on ~ continuous C ~ basis and <!isplaying that quantity on a readily accessible display divice; or -
D § 121(f)4 Another method approved by the Commission.
Service Water Heating Systems
D § 113(b)2 If a circulating hot water system is installed, it shall h~ve a-control capable of
automatically turning off the circulating pump(s) when hot water is no.t required.
D § 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the
.. . . outlet temperature to 110 degrees F •
EnergyPro _By EnergySoft User Number: User · Job Number: 4339H Page: 17 of 17