HomeMy WebLinkAbout2728 LOKER AVE W; ; CB050521; PermitV ~(o # City of Carlsbad , · v(\ ~ \\o~ 1635 Faraday Av Carlsbad, CA 92008
03-10-2oosl V Commercial/Industrial Permit Permit No: csosos21
Building Inspection Request Line (760) 602-2725
Job Address: 2728 LOKER AV WEST CBAD
Permit Type: Tl Sub Type: INDUST
0
NEW
Parcel No: 2090812900 Lot#: Status:
Valuation: $5,873.00 Construction Type: Applied:
Occupancy Group: Reference#: Entered By:
Project Title: PALOMAR TECH-INSTALL STORAGE
RACKS
Applicant:
RICK LIEN
P O BOX 930 9207 4
(619) 339-7425
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
STD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$68.89
$0.00
$44.78
$0.00
$0.00
$1.23
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
FENTON HG COMPANY
7588 METROPOLITAN DR
SAN DIEGO CA 92108
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF
PFF (CFO Fund)
License Tax
License Tax (CFO Fund)
Traffic Impact Fee
Traffic Impact (CFO Fund)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
TOTAL PERMIT FEES
ISSUED
02/18/2005
LSM
03/10/2005
03/10/2005
Total Fees: $114.90 Total Payments To Date: $44. 78 Balance Due:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$114.90
$70.12
BUH.1 3558 03/10/05 0002 0.1.
FINAL APPROVAL
Inspector: Date: ~ Clearance: _____ _
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions, If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired.
02
70-12
~td-cro---
PERM'IT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
Address (include Bldg/Suite #)
Legal Description Lot No. Subdivision Name/Number
;1 t:> 'j-o~ I -~ 'Y
Assessor's Parcel #
/ AJ j 77+-f-L $ ;?>Mt;. E""
/1 A . Existing Use
l'vre../e!,$
Description of Work SQ. FT. #of Stories
Name Address
: : II·contractor: -,liFAseni'ior,:contractcir.! ... . . .. Po ...
Name Address City
'4... PROPERTY OWNER
1 Name Address City
~5, QQI\IJRACTO!h CQMPANY'NAMJ;
FOR OFFICE USE ONLY
PLAN CHECK NO. C,_,,,f.::> Df>l) ~-a-,/
EST. VAL. 6-S-73 o'o
Plan Ck. Deposit 'fl.f. 7~
Vat;dated Bv~~
Date .9-. ~
Unit No. Phase No. Total # of units
Proposed Use
# of Bedrooms # of Bathrooms
State/Zip Telephone # Fax #
Telephone#
S,tate/Zip Telephone#
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exempticp:t, , n violation of Sectio~ 7031.5 b an applicat\t ffr a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
L.o .f'e.5~ c..-\-e.vi'c.. ¼d h1v"\ l2-CP06 5f-ov->~Dv-Sf-c~ '?c.~ c...l<i·<t'ZOls>'t S°b~Cf&ia9ZO
Name Address City State/Zip elephone #
State License # 7 6 7 7 Y 2. License Class J2 2--l 'D 2 f City Business License # 12. I 7 '2..C> S
J
Designer Name Address City State/Zip Telephone
, State License # 7 b 7 7 '{ l--
~;·:-.WOR!<~)js• CQMi>tN.~ATJOrf': :_: . . . ,
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
\ D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued. ':rJ I have and. will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
~ued. My worker's compensation insurance carrier and policy number are: ,/ ,,.-
Insurance Company a,,__-1-e:.. fu v'\d. Policy No. (?C::•2:5'~ / 'i -2<::)0 L Expiration Date %-( -~ ~
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS)
D CERTIFICATE OF EXEMPTIO : I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Worke ' ompensation Laws of California.
WARNING: Failure to secur kers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,0 , · addition to the cost of compensation, damages as provided for in Section 3706 of the Labo cod , interest and attorney's fees.
SIGNATUR~::~::/4L~============~:,._-=-_ _:_-:---;--:---DATE / 0 0 S"'° .
:. . .. OWNER"Bi.JltDE . . . . . . . . _ · , , .
I hereby affirm that I exempt from the Contractor's License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
D I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improveme~2£3 Y62/.18~5 0002 01 02
2. I (have/ have not) signed an application for a building permit for the proposed work. CGF" 44 = 78
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________________________________ _
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number/ type of work): ________________________________________________________ _
PROPERTY OWNER SIGNATURE _____________________ _ DATE _________ _
~IYIPLETij;i'tfil.S ,$1;:0TiON ·F9P,..N,ON•ijESIDENTIAL/P,Ul~DIN(., :P!:RMITS.ONL'Y
ls the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
:~. ,.,.;~9.l'l~Jlj!JCT;IOj)IJ .. 1;:ND.l~~ MENC:Y,, .. ; .. ·. ·~,.. ":;.:_:" . ::,:
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME______________ LENDER'S ADDRESS ________________________ _
~; ,<APP.Ji.l«;:AN'l'.,,C!;JH!fl<,Art.ON'. . ,. , . , , . , · . . · " -: : :. , . --.
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is uspended or abandoned
at any time after the work is com ecl for period of 1 ,ays (Section 106.4.4 Uniform Building Code).
DATE
WHITE: File YELLOW: Applicant PINK: Finance
v
City of Carlsbad Bldg ln_spection Request
For: 03/11/2005
Permit# CB050521
Title: PALOMAR TECH-INSTALL STORAGE
Description: RACKS
Type: Tl Sub Type: INDUST
Job Address: 2728 LOKER AV WEST
Suite:
Location:
APPLICANT RICK LIEN
Owner:
Remarks:
Total Time:
CD Description
Lot
14 Frame/Steel/Bolting/Welding
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
0
Act
Af_
ti!-
~ t
Associated PCRs/CVs
Inspection History
Comment
Date Description Act lnsp Comments
Inspector Assignment:
Phone: 6197237930
Inspector:?
Requested By: MARK
Entered By: CHRISTINE
CilY of Carlsbad
· Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite .::-Frre-:-'
Plan Check #:
Permit#: CB050521
Project Name: PALOMAR TECH-INSTALL STORAGE
RACKS
Address: 2728 LOKER AV WEST
Contact Person: ANITA
Sewer Dist: CA
lnspe~-By: ;,ti,.....---
Inspected
By:
Inspected
By:
Phone: 8584866920
Water Dist: CA
Date ¥ /, Inspected:// ,~5-
Date
Inspected:
Date
Inspected:
Date:
Permit Type:
Sub Type:
Lot: 0
Approved: /
Approved:
Approved:
03/11/2005
Tl
INDUST
Disapproved: __
Disapproved: __
Disapproved: __
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••a•••••••••••••••••••••••••••••••••••1111111111111111111111
Comments: ------------------------------
EsGil C9rporation
In <Partnersli.ip witli. qovernment for (J3ui{aing Safety
DATE: 3/9/05 ANT
.
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 050521 SET:11 1
CJ EVIEWER
CJ FILE
PROJECT ADDRESS: 2728 Loker Ave. West
PROJECT NAME: Storage Racks for Palomar Technologies
D
D
D
D
D
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: ~-Telephone#:
Date contacted: (by: ) Fax #:
Mail Fax In Person l
REMARKS: 1 ire Department approval is required. City to Field verify that the path of travel
from the ha icapped parking space to the rack area and the bathrooms serving the rack area
comply with all the current disabled access requirements.,
By: David Yao Enclosures: ·
Esgil Corporation
D GA D MB D EJ D PC log trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In CFartnersli.ip witfi. government for (]Juiftfing Safety
DATE: 3/4/05
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 050521
PROJECT ADDRESS: 2728 Loker Ave. West
SET:I
PROJECT NAME: Storage Racks for Palomar Technologies
0 APPLICANT
oc:[URIS.~
0 PLAN REVIEWER
D FILE
D The plt;1ns transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted he~ewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
r;gj The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
r;gj The applicant's copy of the check list has been sent to:
Rick Lien P. 0. Box 930 Poway, CA 92074
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
r;gj Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Rick Lien ( v. J.-1) Telephone#: (619)339-7425
Date contacted:':, l 1-{ o5 (by: IC---) Fax #:
Mail Tolephone-.....-' Fax In Person
D REMARKS:
By: David Yao Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 2/24 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City ·or Carlsbad 050521
3/4/05
GENERAL PLAN CORRECTION LIST
JURISDICTION: City of Carlsbad
PROJECT ADDRESS: 2728 Loker Ave. West
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 2/24
REVIEWED BY: David Yao
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 050521
DATE REVIEW COMPLETED:
3/4/05
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments. ·
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
D Yes D No
City 6f Carlsbad 050521
3/4/05
1. Please make all corrections on the original tracings, as requested in the correction list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the _plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete.
2. Only the storage racks are included in this plan review
3. Provide a statement on the Title Sheet of the plans that this project shall comply with
Title 24.
4. Provide a note on the plans indicating if any hazardous materials will be stored and/or
used within the building which exceed the quantities listed in UBC Tables 3-D and 3-
E.(Note on sheet 2 not clear)
5. City to field verify that the path of travel from the handicapped parking space to the rack
area and the bathrooms serving the rack area comply with all the current disabled access
requirements. Title 24, Part 2.
6. Obtain Fire Department approval for groups F, Mand S occupancy storage per UBC
Sections 306.8, 309.8 and 311.8.
7. Provide forklift protection per Section 2222.5.(or check the exception)
8. Recheck all connections on sheet as follows:
a) The rivet bearing capacity is only dtFu = 0.406(0.0747)65 = 2 kips.
Provide calculations for all beam to bracket weld capacities per Section 2330
(allowable weld stress is the member thickness times-26 ksi times 1.33, or the
weld stress, whichever is lower).
b) Check the bracket maximum weak axis moment.
9. Provide calculations for the column weak axis bending plus axial for transverse seismic
loading. The axial load is the maximum compression load at the base from vertical plus
seismic overturning. The column moment will probably be maximum for the lateral load
from the base plate to the first diagonal brace (not only to the first horizontal member).
;
':
eity·of CarlsbacJ. 050521
3/4/05
10. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform
the plan review for your project. If you have any questions regarding these plan review
items, please contact David Yao at Esgil Corporation. Thank you.
City·of Carlsbad 050521
3/4/05
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: David Yao
PLAN CHECK NO.: 050521
DATE: 3/4/05
BUILDING ADDRESS: 2728 Loker Ave. West
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
BUILDING AREA Valuation Reg. VALUE
PORTION ( Sq. Ft.) Multiplier Mod.
storage racks per city
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1994 UBC Building Permit Fee ~1
1994 UBC Plan Check Fee ~,
Type of Review: 0 Complete Review D Structural Only
D Repetitive Fee
3Repeats
Comments:
D Other
D Hourly I_ I Hour *
Esgil Plan Review Fee
($)
5,873
5,873
$68.89!
$44.781
$38.581
Sheet 1 of 1
macvalue.doc
MAR-07-2@05 f?:33 FROM:CMH INC 8584866925 T0:18585601576
RACK DESIG-N & ENGINEERING CO. 8Y ·. G •. Qr!ANIA~ 412 WEST BROADWAY, SlnTE #20.f.
. OA'TE. .... .'J.-:: 1. '.". .. ~ ?.. .. · Gl,ENJ)ALE, dA. SH204
SUBJE:Cl...... . .. .. ... ... ttt:(818)2,60-3810 FAX:(818)~O-3813
~ L.OM..,,. -re<~IVDL&Jt;1e
,
, -~AC"/cJ /Jfs'I.~~" r,,'-'I .,.-,,,,,7 J.>AlfA~cr 7ll hf,,., 1
8--
l 4'-)
(JJ}
(CI
r /,,.._ .,. ... r I"'.,.,. ,,
-,.--.... , .. ,
SMHT NO.
JOB NO ... #Z.J; ?V95"
4
BY ... \ .... 9:.: .. :9.HAN!A~ ....
DAT.E ...... J .. :-::~.~.:~~·······
SUBJECT. ........ '!' ............. , ..
RACK DESIGN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE,. CA. 91204
TE_L:(818)957-2980 FAX:(818)240-3813
STRUCTURAL CALCULATIONS OF STORAGE
RACKS FOR:
PALOMAR TECHNOLOGIES
2728 LOKER AVE. WEST
CARLSBAD, CA. 92008
PER CBC 2001 EDITION
STORAGE RACKS CAPACITY:
1 500 # / l,EVEL
CALCS. 1 THRU 4
DRAWINGS: RD-9495
SHEET. NO •........... ! ............ .
JOB NO •....... ~.~.-::-.~.1.~.~ ..
BY : ....... 9.: ... ,9..~AN!A.tL..
DATE ...... ~.::::~.~.:-:-:_q:? ...... .
• SUBJECT. ........ ,.-,. ........... ,. ..
l
~ sj-
'~
;:-~ sj-.;-
~
~
0 c:o
1-,. ..
LB311 BEAM·
~
fEto:,
II) . ~ ·-t~~::·.~· X
J, . 2 3/4" J
CBC 2001 SEC. 2222
SEISMIC DESIGN
V= 2.5xCaxl x W
Rx 1 ·4 woRKJNG
I= 1 STRESS
RACK DESIGN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE, CA. 91204
TEL:(818)957-2980 .FAX:(818)240-3813
106"
··.~. · .
lx=1.6
Sx=.8
Fy =50 KSI.
f
: . •·.
l 42"
l
~ .;-
~ .;-
k
•.•• 'i,.
1500 #/LEVEL+ 25% IMPACT LOAD
700 # / BEAM
106" 7K " M=. x. = 9 K
8
SR= ~O = .3<.8
11 = 5xWxL3 = .4" _lQ.§_ = .58"
384xlx xE < 1 80
LONGIT. SEISMIC
R=5.6
R=4.4
Ca=.44
W=D.L.+L.L.
LONGIT. DIR. (MOM. CONN.)
TRANSV. DIR. (BRACED)
f--------1-----<-• 1 6 K
LOAD PER COLUMN
P= 3x1 .5K=2.3 K
2 col
W=.1 o.i::z·tL=:=2.4 K
v = 2.5x.44x2.4 = 33 K
LONGIT. 5 • 6 X 1 . 4 '
v = 2.5x.44x2.4 = .42 K
TRANS. 4. 4X 1 • 4
0 c:o
f--------!t---. 11 K
,___ _____ ,___.06 K
SHEET NO ........... ? .......... .
JOB NO ........ ~P.-::-?1.~.~ ..
"K 3 .
3 "K 5_"K
5 "K 1 o""K
1 o"K
BY~ .•...... ~.:...9.H~N!A.N. ... .
DATE ...... ~.::~:?~.:9.~ ...... .
• SUBJECT... ..... £ .............•...
RACK DESIGN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE, CA. 91204
TEL:(818)957-2980 FAX:(818)240-3813
COLUMN ·ANALYSIS
1 5/8" ·%,
1' 15 n[~C E
Fy=50 KSI
A=.4
Sx=.5
rx=1.1
ry=.62
.K! = __§_Q_ = 55 rx 1.1
.Kl= 42 =67 ry .62
SHEET NO .......... .:? ............ .
JOB NO ........ ~P.~.~.1.~.?. ..
p = ___f_rr_ = 9 K
a 1.92
COMBINED STRESS RATIO
BASE PLATE
10 -(2.4 x3") ANCH. TENSION= __ ...,_ __ ...__ = .5 K
6"
ANCHOR SHEAR = .42 = .22 K
2
(2)-1/2"¢ WEDGE TYPE ANCHORS
ICBO #4627, OR #1372. (NO .INSPECTION REQ'D)
DESIGNED FOR 1 /2 STRESS
MOMENT AT BEAM CONNECTION
· M _ 1 0+5 _ 7 5 "K
I -2 -•
.. . .. :· .. .. ... ·
.... -.~. . : ... · .• .
ASTM A354-79
. . ..... •.
2 PIN CONNECTOR
7 /16"¢ RIVET
A = .1 Fy = 79 KSI
Va = .1 x79x.4 = 3.0 K
7 3/ 4"x5"x3/8"
BASE PLATE
.. •,. ~ ..
TH'K=3/16"
Ma = 3.0 Kx4"x1 .33 = 15"K CONN.
BY ~ .•...... Q.~ .• .9.t!!.'!~!A.~ ... .
DA TE ...... ~.::::?:~.:-:-:·9.~ ...... .
• SUBJECT.. ...... ,. ......... , .... ,. .. .
TRANSVERSE SEISMIC
(OVERTURNING)
RACK DESIGN & ENGINEERING CO.
. 412 WEST BROADWAY, SUITE #204
GLENDALE, CA. 91204
TEL:(818)957-2980 FAX:(818)240-3813
TOP LEVEL LOADING
SHEET N0 ........... 4. .......... ..
JOB NO ........ ~.l?::-:-.~.4?~ ..
K " "K Mor= .42 x2 x144 x.5x1.15 =70 COL.
K. " "K MOT = . 14 x2 X 1 44 = 40 ·
MR = 2.4 Kx42"= 101 "K
NO UPL:IFT
LOAD TO DIAGONAL
p = .42 KX2 X ~ = 1.5 K
COL. 42
Fy=50 KSI
A=.31
rx=.48
• Q:=.74
L= 56"
CHECK WELDS
Fa= 11'.2 KSI
Pa= 3.5 K
1 /8" WELD 1.5" LONG EACH SIDE (3" TOTAL)
3x. 125x. 707x70x.3 = 5. 7 K
CHECK SLAB
2400 #
5" CONCRETE SLAB
2000 PSI. CONC.
1000 PSF. SOIL
..
·:. ; ~ i.•.A ·:. ~. •=,:: • > .. ·. : ",A· ~ . :~ : ..
20"
5.5" 4.5"
10"
COL.
MR =1 K x42"= 42 "K
BOTH_ SIDES 1YP. 1 /S
1 1/2" ' 11 >fAx
~ t=.07"
SEC. A-A
SEC. 8-8
2400 = 2 4 o'
1000 ' 2.4x 144=345 o"
V345 =20''
M= (~)2 x1 OOOx _j_ x12 = 844 "# 12 2
S= 12x52 = 50 6
ii4 = 17 < 1.6 v'2ooo =72
\-\-VZb -2.:1?> OFFICE USE ONLY
SAN DIEGO REGIONAL J37,,oo
HAZARDOUS MATERIALS QUESTIONNAIRE
t \f lS-D
UPFP#: rJO 4 g'O Y
BP DATE: ---'----'/'--_
\
Business Contact
V\C •
Telephone# ,tv,.nu._ ' ( "¼o) q~ l .,-3<oz;o;
City State Zip Code
9'2.00</
T~ephone #
((9\C\_)l,th &~&4-
he fo owing q stions represent tl)e lity's activiti s, NOT the specific project description.
PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your
business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire .Protection Agency
with jurisdiction prior to plan sub,:nittal.
1. Explosive or Blasting Agents 5. Organic Peroxides ~ Water Reactives 13. Corrosives
(lJ) Compressed Gases 6. Oxidizers Q.1!.> Cryogenics 14. Other Health Hazards
-@ Flammable/Combustible Liquids 7. Pyrophorics 11. Highly'ifoxic or Toxic Materials 15. None of These
4. Flammable Solids 8. Unstable Reactives 12. Radioactives
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISIONS (HMO): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3rd floor, San Diego, CA 92101.
Call (619) 338-2222 prior to the issuance of a building p~rmit. ·
FEES ARE REQUIRED. Expect_ed date of Occupancy 5 / ) / D 5
YES
1. a
2. 'tgL
3. ~
4.
5.
6.
D D
D
~ Is your business listed on the reverse side of this form? D Will your business dispose of Hazar9ous Substances or Medical Waste in any amount?
D Will your business store or handle Hazardous Substances in quantities equal to or ·greater 11i!OO fl?·-lG-115 10· 10
55 gallons, 500 pounds, 200 cubic. feet, or carcinogens/reproductive toxin? in any quantity? --P!-!if" • ~ 'gf_ Will your business use an existing or install an.underground storage tank? · l:i ...
~ Will your business store or handle Regulated Substances (CalARP)?
~ Will your business use or install a Hazardous Waste Tank System (Title 22, Article 1 0)?
0 CalARP Exempt
I
D CalAAP Required . RlEE I t5b?Wl
D $:.37~11.nn CalAAP Compfe1ev
I
Date Initials
PART Ill: San Diego County Air Pollution Control District: If the answer to any of the questions below is yes, applicant must-contact the Air Pollution Control
District (APCD), 9150 Chesapeake Drive, San Diego, CA 92123, telephone' (858) 650-4550 prior to the issuance of a building or demolition permit. Note: if the
answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commen~ing demolition
or renovation, except demolition or renovation of residenti<!,1 structures of four units or less. Contact the APCD for more information.
YES t!_9
1. D C'A_ Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See
the APCD fact sheet at http://www.sdapcd.org/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse
side of this form. Contact APCD if you have any questions.)
2. D D (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)?
(Public and private schools may be found after search of the California· School Directory at http://www.cde.ca.gov/re/sd/; or contact the
appropriate school district.)_ ·
3. D D Will there be renovation that inv21ves handling of any friable asbestos material, or disturbing any material that 9ontains non-friable asbestos?
4. D . D Will there be demolition involvin the removal of a load su ortin structural member? e: or"' ~ \,. -\!p-'\ ?.-• i
Briefly describe business activities: , Briefly describe proposed project:
~\~ &.~ \oonlle.ir-.s <-Wtr-e.. ~~ecs ~ \,I ,Yt)'>J~
y knowledge a
~-Z-f t>j -I 61'6
Dae· .
FOR OFFICIAL USE ONLY: _
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ____ --=----------------------------
BY: DATE: I I
EXEMPT OR NO FURTHER INFORMATION R!;OUIRED RELEASED FOR OCCUPANCY
COUNTY·HMD APCD APCD APCD