Loading...
HomeMy WebLinkAbout2762 LOKER AVE W; ; CB130874; PermitMINIM m.• City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit 05-30-2013 Permit No: CB130874 Building Inspection Request Line (760) 602-2725 Job Address:2762 LOKER AV WEST CBAD Permit Type:PME Status:ISSUED Parcel No:2090810900 Lot #:0 Applied:04/03/2013 Entered By:LSM Reference #:Plan Approved:05/30/2013 PC #:Issued:05/30/2013 Inspect Area: Project Title:ASYMTEK-NEW PANEL ADDITION WITH NEW TRANSFORMER THREE PHASE 480 IN EXISITNG METER ROOM Applicant:Owner: JESSICA BORDERS CARLSBAD OAKS NO 1 L P 17065 CAMINO SAN BERNARDO 1000 PIONEER WAY SAN DIEGO CA 92127 EL CAJON CA 92020 858-673-4445 Plumbing Fees $0.00 Electrical Fees $154.00 Mechanical Fees $0.00 Other PME Fees $375.00 TOTAL PERMIT FEES $529.00 Total Fees:$529.00 Total Payments To Date:$529.00 Balance Due:$0.00 FINAL APPROVAL Inspector:th•Date:ogitz(is Clearance: NOTICE:Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions."You have 90 days from the date this permit was issued to protest imposition of these fees/exactions.If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030.Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project.NOR DOES IT APPLY to any fees/exactions of which you have previously been oiven a NOTICE similar to this. or as to which the statute of limitations has Previously otherwise expired. ,.. [THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:0 PLANNING 0 ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH 0 HAZMAT/APCD Plan Check No.ce.1 SOS -74Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value\1,/CITY 0 F Ph:760-602-2719 Fax:760-602-8558 CARLSBAC)email: buldlIngecarlsbadca.gov Plan Ck. Deposit www.carlsbadca.gov Date if]ai la SWPP JOB ADDRESS SUITECSPACEVUNIT#APN:1V).*L 0 Vel.1/NleMQ-k)jtd±.'L0 °‘-oq -oct -CO- CT/PR •JECT LOT #PHASE ##OF UNITS # BEDROOMS #BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP N00.osco AslmrcK DESCRIPTION OF WORK:Include Square Feetof Affected Area(si I?CVOJZA C 1 aa.0 On (3w9 kcom I.'ot)k°1-1(2)var‘c '.6ci5ic .\.,z.c\-.("t cal / iJ GX.\s-n r.)G-me.Ter 2-00 nn EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE AIR CONDITIONING FIRE SPRINKLERS MCON.•••Un •.(a&V 0 M9CNIO CiCA-Uf I (151 YES Cl #NO/11 YES Cl NO 1:1 YES Cl NO CI APPLICANT NAME (Primary Contact)APPLICANT NAME (Secondary Contact) cvtif\..\3‘es51cPcie0C-06(z-s moNor &145ADDRESSADDRESSnWSecimi(70 Sari PYitlel ay-0(0 1 -)cioj Cary. too San Repnarci 0 CITY STATE al ZIP CITY STATE ZIP PON D 1 ECO'D Cwi (11-1/A-SoP Oiego CA q 2 t 19- PHONE FAX PHONE FAX 565V)tal 3 41-11--k5 '65`b o+-5 I-Li IAS EMAIL EMAILOn 0_1/19e. Con sotthig .corn OPAI 141 tO, v\ii oe consuiii 09.covr1 PROPERTY OWNER NAME n CONTRACTOR SUS. NAME ic).17 cr.eiecca \c.L.Af \slcpci Oci‘4.5 ADDRESS ADDRESSk0opionesWo`l —150 (-)Q02)(.iii-ee;i- CITY —STATE if...ZIP CITY -STATE ZIP \,C cAj on Crl (tin)fscoti A %ot 0 Q A-C12.02-1— PHONE FAX PHORE FAXltso R3o -)ctoLl i;.-.ic..e.- 1 I- 1 to I 005EMAILAIL • ARCH/DESIGNER NAME & ADDRESS STATE LIC.#TE CLASS CITY BUS. LIC.#Mg-tw25 I 13 o 1-kl.p C. \O 1 IN Ce 00 (Sec.7031.5 Business and Professions Code; Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure. prior to its issuance, also requires theapplicant for such permit to file a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law 'Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he Is exempt therefrom, and the basis for the alleged exemption.Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). WORKERS'COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 16 I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. O I have and will maintain workers' compensation,as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation Insurance carrier and policy number are: InsuranceCo.10.0vt./5 \N?-cos co:50.9ml Policy No.41e.v)vbciLict 4 Rto fin %2._Expiration Date —1 ""1 —1.3 This section need not be completed if the permit is for one hundred dollars ($100) or less.O Certificate ofExemption:I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California.WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (8100,000), In addition to the cost of compensation, dam ,_.as provided forI ,z ection 3706 of the Labor I.inter rid .eye . AK CONTRACTOR SIGNATURE a #I a a #W .age ,r111C(Ar(lar Nigrr 11WeirS?t'' .. DATE .— OWNER -BUILDER DECLARATION I hereby affirm that (am exempt from Contractor's License Law for the following reason: 71 I,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section Business and Professions Code for this reason: 1.I personally plan to provide the major labor and materials for construction of the proposed properly improvement.0 Yes 0 No 2.1 (have I have not) signed an application for a building permit for the proposed work. 3.I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4. I plan to provide portions of the work, but) have hired the following person to coordinate, supervise and provide the major work (include name/address / phone I contractors' license number): 5.I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address/phone / type of work): 41 AKPROPERTYOWNER SIGNATURE "[AGENT DATE IA —3 -13 1110110.111.11 COMPLETE THIS SECTION FOR NON -RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505. 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?I3 Yes Is the applicant or future building occupant required to obtain a permit fro;(he pollution control district or air quality management district?el Yes 7(flo Is the fadlity to be constructed within 1,000 feet of the outer boundary of a school site?GI Yes IF ANY OF THE ANSWERS ARE YES,A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UgS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 30910) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certifythatl ham reedtheapplkatIon and abatethatthe abcne Intommlonla coned and that the InfonnatIon on the plans la accuiste. Imeet°cornpiyMth allIllyradlnances and Slate lava relating)) bulking conseuctIon. Ihereby aulhorbs representative of the CityofCarlsbadbenter upon the above mentioned properly for inspection purposes.I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILMES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CCNSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demordion or construction ofstructures over 3 stories in height. EXPIRATION: Every permit issued by theBuffing Oficial under the provisions of this Code shallwireby imitation and become null and void if the building or work authorized by such permit is not commerced within 180 days from the dateof such permit buirrng or work by •is suspended or abandoned at any time after the works commenced foraperiod of180 days (Section 106.4.4 Uniform Building Code). ..0dAPPLICANT'S SIGNATURE DATE ti -3 -13 • • STOP STOP:THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email torww.buildiria@carlsbadca.aav or Mall the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO*: (Moe Use Only) CONTACT NAME OCCUPANT NAME ADDRESS .BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. UC. No. DELIVERY OPTIONS D PICK UP:o CONTACT (Listed above)o OCCUPANT (Listed above) o CONTRACTOR (On Pg 2.) a ASSOCIATED CB00MAIL TO:o CONTACT (Listed above)o OCCUPANT (Listed above) o CONTRACTOR (On Pg i) NO CHANGE IN USE/NO CONSTRUCTION D MAIL /FAX TO OTHER: a CHANGE OF USE/NO CONSTRUCTION AKAPPLICANT'S SIGNATURE DATE Inspection List Permit#:CB130874 Type:PME ASYMTEK-NEW PANEL ADDITION WITH NEW TRANSFORMER THREE PHAS Date Inspection Item Inspector Act Comments 06/11/2013 13 Shear Panels/HD's RI 06/11/2013 19 Final Structural RI 06/11/2013 34 Rough Electric MC AP PER PLAN 06/11/2013 39 Final Electrical MC FI Wednesday, June 12, 2013 Page 1 of 1 EsGil Corporation In Tartnership with governmentfor •Buitling Safety DATE:05/22/2013 AP_PLIC NT JURIS. pJURISDICTION:Carlsbad REVIEWER 0 FILE PLAN CHECK NO.:13-0874 SET:III PROJECT ADDRESS:2762 Loker Avenue West PROJECT NAME:NORDSON ASYMTEK The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. E The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. E The check list transmitted herewith is for your information.The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. n The applicant's copy of the check list has been sent to: [xi EsGil Corporation staff did not advise the applicant that the plan check has been completed. n EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:Telephone #: 858.673.4445 Date contacted:(by:)Email:jessicab@mpeconsulting.com Fax #: Mail Telephone Fax In Person Li REMARKS: By:Eric Jensen Enclosures: EsGil Corporation ID GA ID EJ PC 05/16 9320 Chesapeake Drive, Suite 208 •San Diego, California 92123 •(858) 560-1468 •Fax (858) 560-1576 EsGil Corporation In Partnership with governmentfor Building Safety DATE:04/30/2013 A"-•ANT 41C0 JURISDICTION:Carlsbad U PLAN REVIEWER 1:1 FILE PLAN CHECK NO.:13-0874 SET:II PROJECT ADDRESS:2762 Loker Avenue West PROJECT NAME:NORDSON ASYMTEK The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 171 The check list transmitted herewith is for your information.The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ri The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ri The applicant's copy of the check list has been sent to: In EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:Telephone #: 858.673.4445 Date contacted: 4130113 (by: (a-)Email:jessicab@mpeconsulting.com Fax #: t Mail.'Telephone Fax In Person n REMARKS: By:Eric Jensen Enclosures: EsGil Corporation 1=1 GA 0 EJ 0 PC 04/24 9320 Chesapeake Drive, Suite 208 •San Diego, California 92123 •(858) 560-1468 •Fax (858) 560-1576 ..mmommo. Carlsbad 13-0874 04/30/2013 GENERAL PLAN CORRECTION LIST JURISDICTION:Carlsbad PLAN CHECK NO.:13-0874 PROJECT ADDRESS:2762 Loker Avenue West DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION:04/24 04/30/2013 REVIEWED BY:Eric Jensen FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code,Uniform Plumbing Code,Uniform Mechanical Code,National Electrical Code and state laws regulating energy conservation,noise attenuation and disabled access.This plan review is based on regulations enforced by the Building Department.You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change.All items must be satisfied before the plans will be in conformance with the cited codes and regulations.The approval of the plans does not permit the violation of any state, county or city law. •Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. •To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. •Please indicate here if any changes have been made to the plans that are not a result of corrections from this list.If there are other changes, please briefly describe them and where they are located on the plans.Have changes been made not resulting from this list? Yes No ....moommoimmen mimeo. Carlsbad 13-0874 04/30/2013 •ELECTRICAL PLAN REVIEW •2008 NEC (2010 CEC ) 1.The tap conductors are more than 10'.CEC 240.21(6)(2) applies in lieu of (1)Hence, the conductors are undersized. Review requirements of the Code section. 2.Where equipment exceeds 6ft in width then 2 entrances are required for access to the equipment room.With the new 800 amp disconnect within the 6' area in front of the existing 3000 amp service it may be a code violation depending on exact dimensions. Please review.NEC(CEC)110.26(C)(2).This is a troublesome comment as the submitted original design does not appear to comply with Code, let alone with the added 800 ampere disconnect.The distance between the wall and the existing service has to be at least 7'((2 X 3'6')(Table 110.26(A)&CEC 110.26(C)(2)),and that doesn't scale. Include a dimensioned layout with room dimensions,equipment dimensions and 110.26 clearances all detailed. 3.Provide required transformer ventilation.NEC(CEC) 450.9 Impossible to determine the design of the room that the new 300KW transformer is installed therein:Is it open, closed?What is the existing ventilation? The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Eric Jensen at Esgil Corporation.Thank you. er.walsOMMINNIMIMI 111.111.11.1.1 •. EsGil Corporation In (Partnership with governmentfor Building Safety DATE:04/10/2013 OzAPPLICANT JURIS. JURISDICTION:Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.:13-0874 SET:I PROJECT ADDRESS:2762 Loker Avenue West PROJECT NAME:NORDSON ASYMTEK 7 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information.The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. l>1 The applicant's copy of the check list has been sent to: Jessica Borders 17065 Camino San Bernardo San Diego, CA. 92127 EsGil Corporation staff did not advise the applicant that the plan check has been completed. X EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:Telephone #: 858.673.4445 Date contacted:4111 (by:)4.)Email:jessicab@mpeconsulting.com Fax #: \r„1114 4eleqcre Fax In Person E REMARKS:V.'10) By:Morteza Beheshti Enclosures: EsGil Corporation 0 GA 0 EJ 0 PC 04/04 9320 Chesapeake Drive, Suite 208 •San Diego, California 92123 •(858) 560-1468 •Fax (858) 560-1576 • Carlsbad 13-0874 04/10/2013 GENERAL PLAN CORRECTION LIST JURISDICTION:Carlsbad PLAN CHECK NO.:13-0874 PROJECT ADDRESS:2762 Loker Avenue West DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION:04/04 04/10/2013 REVIEWED BY:Morteza Beheshti FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code,Uniform Plumbing Code,Uniform Mechanical Code,National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access.This plan review is based on regulations enforced by the Building Department.You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change.All items must be satisfied before the plans will be in conformance with the cited codes and regulations.The approval of the plans does not permit the violation of any state, county or city law. •Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. •To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. •Please indicate here if any changes have been made to the plans that are not a result of corrections from this list.If there are other changes, please briefly describe them and where they are located on the plans.Have changes been made not resulting from this list? Yes No 6.0.0001.1.01.110.11.10111111.111.11111.0110.11111111 • Carlsbad 13-0874 04/10/2013 ELECTRICAL PLAN REVIEW 2008 NEC (2010 CEC ) 1.The tap conductors are more than 10'.CEC 240.21(6)(2) applies in lieu of (1)Hence, the conductors are undersized. 2.Indicate on single line what the secondary ground electrode will be.CEC 250 3.Submit load calculations for existing commercial service.Include long continuous loads (LCL)and the largest motor loads.Demonstrate service adequacy by showing compliance with NEC(CEC) 220.40 or NEC(CEC)220.87 4.Specify the wiring method you intend to use for this project.Indicate the type of conduit to be used when exposed or buried underground, etc. (i.e., EMT, Metal Flex, NMC etc.). NEC(CEC) 110.8 5.Where equipment exceeds 6ft in width then 2 entrances are required for access to the equipment room.With the new 800 amp disconnect within the 6'area in front of the existing 3000 amp service it may be a code violation depending on exact dimensions. Please review.NEC(CEC) 110.26(C)(2). 6.Provide the required working space about electrical equipment.NEC(CEC) 110.26. 7.Show the "nearest electrode" used for each transformer secondary ground system (i.e., building steel, cold water pipe). NEC(CEC) 250.30(A) (7) 8.Provide required transformer ventilation. NEC(CEC) 450.9 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Morteza Beheshti at Esgil Corporation.Thank you. 1111111111111111111111111 •, Carlsbad 13-0874 04/10/2013 EDO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION:Carlsbad PLAN CHECK NO.:13-0874 PREPARED BY:Morteza Beheshti DATE:04/10/2013 BUILDING ADDRESS:2762 Loker Avenue West BUILDING OCCUPANCY:TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg.VALUE ($) PORTION (Sq. Ft.)Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance Bldg.Permit Fee by Ordinance w Plan Check Fee by Ordinance w $375.00 Type of Review:0 Complete Review Structural Only Repetitive OtherFee w I Repeatss Hourly 3 Hrs. @* EsGil Fee $100.00 $300.00 *Based on hourly rate Comments:Electrical plan review only. Sheet 1 of 1 macvalue.doc + Job Name: 13-0874 Plan File No.: Nordson Asymtek RESPONSE PLAN REVIEW SHEET FOR PLAN CHECK COMMENTS RESPONSES 1.The tap conductors are more than 10'.1.Feeders revised. CEC 240.21 (B)(2) applies in lieu of (1) hence the conductors are undersized. Review requirements of the code section. 2. Where equipment exceeds 6ft in width 2. Gear Relocated the 2 entrances are required for access to the equipment room. With the new 800 amp disconnect within the 6' area in front of the existing 3000 amp service it may be a code violation depending on exact dimensions. Please review. This is a troublesome comment as the submitted original design does not appear to comply with code, let alone with the added 800 ampere disconnect. The distance between the wall and the existing service has to be at least 7' ((2x36)(Table 110.26(A) & CEC 110.26(c) (2)) and that doesn't scale. Include a dimensioned layout with room dimensions and 110.26 clearances all detailed. 3.Provide required transformer 3.Existing Ventilation to remain. ventilation. NEC (CEC) 450.9 impossible to determine the design of the room that the new 300kw transformer is installed therein: Is it open, closed? What is the existing ventilation? RECSIVE° MAY 1 b 203 CITY OF CARLSBAD BUILDING DIVISION