HomeMy WebLinkAbout2792 JAMES DR; ; CB162195; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-10-2016 Residential Permit Permit No: CB162195
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
2792 JAMES DR CBAD
RESDNTL Sub Type: SFD
Lot#: 0
Constuction Type: 5B
Reference #:
Status: ISSUED
Applied: 06/07/2016
Entered By: RMA
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms;
1561424800
$483,818.00
1
3
Stnicture Type: SFD
Bathrooms: 2.5
Orig PC#:
Plan Approved: 08/10/2016
Issued: 08/10/2016
Inspect Area:
Plan Check #:
Project Title: BOWLING RE.S-NEW 2974 SF HOUSE
949 SF GAR, 255 $F PORCH/PATIO-ON VACANT LAND//
FREE-STANDING FIREPLACE IN REAR YARD
Applicant:
ALAN ROPER
1443 PANORAMA RIDGE RD
OCEANSIDE CA 92056
760 522-3997
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
$1,989.26
$0.00
$1,392.48
$0.00
$0.00
$62.90
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0,00
·$0.00
$0.00
$904.80
$0.00
$0.00
$0.00
$20.00
$163.00
Owner:
KIM & MIKE BOWLING
2792 JAMES DR
CARLSBAD CA 92008
760 594-2884
Meter Size·
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
. Housing Credit Fee
Master Drainage Fee.
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAi:. PERMIT FEES
Total Fees: $30,486.49 1otal Payments to Date: $30,486.49 Balance Due:
$0.00
$0.00
$0.00
$0.00
$8,805.49
$8,128.14
$0.00
$0.00
$3,160.00
$0.00
$0.00
$240.00
$89.00
$135.42
$0.00
$4,515.00
$0.00
$0.00
$881.00
$0.00
$0.00
$30,486.49
$0.00
Inspector: ~ Clearance: _____ _
l'JO'llCE: Please take NOTICE that awiwaf d'yoor ptject includes the "lrrposition" cf fees, dooications, reservations, or other exactions hereafterCXJllectively
referred to as ''fees'exactions." Yoo have 9J days frcrn the date this pemit WaS issued to protest irrposition cf these fees'exactions. If yoo protest them, yoo rrust
· fdlotvttie protest p,:x;ec:lres set forth in Go/et'm"ent Ccxle Section 60020(a), and file the potest and any other requred infooration wth the Oty ~ for
puressing in acxxirclarre wth c.aisboo M.nidfEI Ccxle Section 3.32.030. Failtre to tirrely fdlotv that p-ocootre wll bar any subsequent legal oction to attack,
re-iiem, set aside, wid, or annul their irflX)Sition.
Yoo are herecy FLRll-ERNOTIFIEDthatya.rrigitto ixotest thespecifiedfees'exactions Da:S NOT APPLY to water and SEMerCXJ11nectionfeesand ~ty
~. nor planting, zming, g-ac:f ng or other sinilar appication p-oqlSSing or service fees in cx:nneqion wth tlis ptject. !'-CR Da:S IT APPLY to any
i i w1i · · · 'nilar t tt-i t w,i the atute lini i has 'ousl ·see 'red.
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-10-2016
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW160268
Job Address:
Permit Type:
Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
MIKE BOWLING
760 594-2884
Emergency Contact:
MIKE BOWLING
760 594-2884
2792 JAMES DR CBAD
SWPPP
1561424800
CB162195
BOWLING RESvNEW HOME
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Lot#: 0
Owner:
AP A TRUST 01-07-05
2785 CRE:ST DR
CARLSBAD CA 92008
Status:
Applied:
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
ISSUED
06/07/2016
RNA
08/10/2016
1
L
$49.00
$59.00
$0.00
$108.00
Total Fees: $108.00 Total Payments To Date: $108.00 Balance Oue: $0.00
"THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: QPLANNING OENGINEERING OBUILDING OFIRE OHEALTH OHAZMAT/APCD
__ .Ccicyof
Carlsb.ad
JOB ADDRESS
CT/PROJECT# LOT#
EXISTING USE VAyiµ[
APPLICANT NAME
CITY
DESIGN P.ROFESSIONAL
ADDRESS
CITY
PHONE
EMAIL
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITE#/SPACE#/UNIT# -PHASE# # OF UNITS # BEDROOMS # BATHROOMS
GARAGE (SF) PATIQS (SF)
1'M1F. -~~'5-::.
PROPE:RTY OWNER NAME ..
ADDRESS
. CITY
EMAIL
CONTRACTOR BUS. NAME
ADDRESS
STATE ZIP .CITY
FAX .PHONE
EMAIL
STATE UC,# STATE UC.#
OGG.GROUP
ZIP cr-u:nB
STATE ZIP
FAX
Cl,ASS CITY BUS. UC.#
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement ttiat he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or niat he is exempt therefrom, and the basis for the alleged exemption. Ariy violation of Section 7031.5 by any applicant for a permit subjects the applicant to a· civil penalty of not more than five hundred dollars ($500)). . ·
")'.!1.¢@
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: D I have and wlll maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers' comp_ensation, ~s required by Section 3?00 of the l,abor Qqde, for the per{ormance of the wo[k f9r which th_is permit /s issueil. My workers' compensation insurance carrier and policy
number are; Insurance Co .. ~~-------------------Policy No. ______________ Expiration Date _________ _
This section n~ed not be completed if the permitis for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permifis issued, I shall.not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in.
addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, interest and attorney's fees •
.fE5 CONTRACTOR SIGNATURE OAGENT ) :~<ii~cim4 ..... _ -. --=---....,..,.,.....,..,,,,,.,,.....,,..,.,....==--==,,..,...,.,~-"""""'=-,,,j
DATE
I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason:
D
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he ~id not build or improve for the purpose of sale).
I, as owner. of the property, am exclusively contracting with licensed contractors to construct the·projecr(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves th.ereon·, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section . . . Business and Professions Code for this reason: 1: I personally plan to provide the major labor and materials for construction of the proposed property improvement. DY es 0No
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (Include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number):
5. I will provide some of the work, but I have contracted (hi the following persons to provide the work indicated (include name/ address/ phone/ type of work):
t?/;Z
.fE5PROPERTY OWNER SIGNATURE OAGENT DATE
I
Is the applicant or future building occupant required to submit a business P,lan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? Yes · 'No
Is the applicant or future building occupant required to obtain a permit from the air pollution control .9istrict or air qyality management district? . Yes No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? :Yes _; :No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
:~~:m~i®i
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
I certifythatl have read the application and state that the above lnfonnation is correct and that the infonnation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property tr inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINSTALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: AA OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height
'EXPIRATION: ~very pennitissued by the Buiiding Official under the provisions of this Code shall expire by \imitation and become null and void if the buiiding or \\Ork authorized by such permit is not commenced 'hithin
180 days from the date of such permit or if the buiiding or authorized by such permit is suspended or abandoned at any time after the \\Ork is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code} .
...@S' APPLICANT'S SIGNATURE DATE
• · , ...... · STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
. ,-..r.ncrc,aI PrOJCCtS only J
Fax (760) 602-8560, Email building@carlsbadca;gov or Mail the completed form to City of Carlsbad, Building Division 1635 F11raday Avenue, Carlsbad, California 92008.
I CO#: (Office Use Only)
CONTACT NAME . OCCUPANT NAME
ADDRESS BUILDING ADDRESS
'' ..
.CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE I FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
·. 'PICKUP: ;'· CONTACT (Listed above) • · -OCCUPANT (Listed above)
,~. C:ONTRACTOR'(On Pg. 1)
ASSOCIATED CB# · -, ·MAIL TO: ",. CONTAC:T (Listed above) · . OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1) -NO CHANGE IN USE/ NO CONSTRUCTION -'
. : •,MAIL/ FAX TO OTHER: ,
,-CHANGE OF USE/ NO CONSTRUCTION
.... ~ ....... " -···· . ...
"
L APPLICANT'S SIGNATURE DATE
-
~
····'.,
. }.:~:
' . '' , !' ,, ""-:
Permit Type: BLDG-Residential Application Date: 0.6/07/2016 Owner: COOWNER KIM AND MIKE
BOWLING
Work Class: Single Family Detached
Closed -Finaled
Issue.Date: 08/10/2016
11/27/2017
715002
Subdivision:
Status: Expiration Date: Address:
IVR Number:
Scheduled Actual Inspection Type Inspection No. Date Start Date Inspection Status Primary Inspector
03/30/2017 03/30/2017 BLDG-Compliance 018255-2017 Pas-sed Peter Dreibelbis
Checklist.Item COMMENTS
BLDG-Building Deficiency
04/28/2017 04/28/2017 BLDG-11 021616-2017 Passed Michael Collins
Foundation/Ftg/Pier
s (Rebar)
Checklist Item COMMEN1:s
BLDG-Building Deficiency Base layer, 1 1/2-2" rock for pervious
driveway.
05/0;3/2017 05/03/2017 BLDG-66 Grout 021974-2017 Pas·sed Andy Krogh
Checklist Item ~OMMENTS
BLDG-Building Deficiency 3/4 rock for permeable driveway system
05/3.0/2017 05/30/2017 BLDG-34 Rough 024781-2017 Falled Michael Collins
Electrical
Checklist Item COMMENTS
BLDG-Building Deficiency
06/06/2017 06/06/2017 BLDG-Fire Final 02537-2-2017 Passed Andy Krogh
C_hecklist Item COMMENTS
FIRE-Building Final Wrong code should be building final
2792 James Dr
Carlsbad, CA
Re inspection
Passed
Yes
Passed
Yes
Passed
Yes
Reinspection
Passed
No
Passed
Yes
Complete
Complete
Complete
Complete
Complete
Complete
June 06, 2017 Page 2 of2
Permit Type: BLDG-Residential Application Date: 06/07/2016 Owner:
Work Class: Single Family Detached Issue Date: 08/10/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 11/27/2017 Address:
IVR Number: 715002
Scheduled Actual Inspection No. Primary Inspector Date Start Date Inspection Type Inspection Status
06/06/2017 BLDG-Final 025593-2017 Passed Andy Krogh
Inspection
Chec.klist l~em COMMEIIJTS
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
11/21/2016 11/18/2016 BLDG-13 Shear 001911-2016 Partial Pass Peter Dreibelbis
Panels/HD (ok to
wrap)
Checklist Item COM.MENTS
BLDG-Building Deficiency
11/22/2016 11/22/2016 BLDG-15 002386-2016 · Passed Andy Krogh
Roof/ReRoof (Patio)
12/20/2016 12/20/2016 BLDG-13 Shear 006235-2016 Passed Michael Collins
Panels/HD (ok to
wrap)
Checklist Jtem COMMENTS
BLDG-Building Deficiency
12/30/2016 12/30/2016 BLDG-84 Rough 0077 40-2016 Passed Andy Krogh
Combo(14,24,34,44)
Chec~list Item COMMENTS
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG.-24 Rough-Topout
BLDG-34 Rough Elegtrical
BLDG-44
Rough-Ducts-Dampers
01/17/2017 01/17/2017 BLDG-17 Interior 009833-2017 Passed Andy Krogh
Lath/Drywall
BLDG-18 Exterior 009834-2017. Passed Andy Krogh
Lath/Drywall
01/18/2017 01/18/2017 BLDG-23 009999-2017 Passed Andy Krogh
Gas/Test/Repairs
03/27/2017 03/27/2017 BLDG-Compliance 017718-2017 Passed Andy Krogh
Checklist Item COMMENTS
BLDG-Building Deficiency Permeable pavement questions
June 06, 2017
. ~·:
., •t: /, '' ·<·: J.--:.
COOWNER KIM AND MIKE
BOWLING
2792 James Dr
Carlsbad, CA
Reinspection Complete
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Reinspection Incomplete
Passed
Yes
Complete
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Complete
Complete
Passed
Yes
Page 1 of 2
EsGil Corporation
In <Partnersliip witli government for (]Jui{aing Safety
DATE: July 28, 2016
JURISDICTION: CARLSBAD
PLAN CHECK NO.: 16-2195
PROJECT ADDRESS: 2792 JAMES DRIVE
PROJECT NAME: SFR FOR BOWLING
SET: II
CJ APPLICANT
~URIS.
CJ PLAN REVIEWER
CJ FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will su_bstantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D rhe applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D ihe applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: -Telephone#:
Date contacted: ~ (by:J IQ Email:
Mail Telephone Fax In Person
D REMARKS:
By: Abe Doliente (for A.S.)
EsGil Corporation
D GA D EJ D MB D PC 7/25/16
Enclosures:
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In (l'artnersliip witli government for <Bui(aing Safety
DATE: JUNE 16, 2016
JURISDICTION: CARLSBAD
PLAN CHECK NO .. : 16-2195
PROJECT ADDRESS: 2792 JAMES DRIVE
PROJECT NAME: SFR FOR BOWLING
SET:I
D AJ>PLICANT
--l:T"JURIS.
D PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith i~ for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
0: The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
l2S] The applicant's, copy Of the check list bas been sent to:
ARLEN ROPER
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
l2S] EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: ARLEN ROPER Telephone#: 760-522-3997
~ate ~cted: l.P,1 i W (byfC--) Email: arlenroper@gmail.com
'\::;,Mail \llej2ho~ Fax In Person D REMA '?)'\.
By: ALI SADRE, S.E. Enclosures:
EsGil Corporation
D GA D EJ D MB D PC 6/9
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
:...-CARLSBAD 16-2195
JUNE 16, 2016
GENERAL PLAN CORRECTION LIST
JURISDICTION: CARLSBAD PLAN CHECK NO.: 16-2195
PROJEC1 ADDRESS: 2792 JAMES DRIVE
OCCUPANCY= R3/U; CONSTRUCTION= V-B; SPR. = YES; STORY= ONE; HEIGHT= 15';
LIVING= 2,974; GARAGE= 949; PATIO COVER= 255
. DATE PLAN RECEIVED BY DATE REVIEW COMPLETED:
ESGIL CORPORATION: 6/9 JUNE 16, 2016
.REVIEWED BY: ALI SADRE, S.E.
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Meohanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• ARCHITl;:CTURAL
• Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for
commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing,
corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building
Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil
Corporation and the Carlsbad Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive,
Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports
directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning,
Engineering and Fire Departments until review by EsGil Corporation is complete.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans
upon which each correction on this sheet has been made and return this sheet
with the revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located on the plans. Have changes been made not resulting from this
list? D Yes D No
.-'l CARLSBAD 16-2195
JUNE 16, 2016
1. Please revise the sheet index to match the content of the plans.
2. Openable windows shall be located a minimum of 1 O' from any plumbing vents,
chimneys, etc. Section R303.5. Please note this on plans.
3. The garage shall be separated from the residence and its attic area by not less than ½"
gypsum board applied to the gara9e side (at walls). Section R302.6.
• STRUCTURAL
4. Please note on plans that surface water will drain away from building. The grade shall fall
a minimum of 6" within the first 1-0'. Section R401.3. This may be done on site plans.
5. Note on the foundation plan that "Prior to the contractor requesting a Building
Department foundation inspection, the soils engineer shall advise the building official in
writing that:
a) The building pad was prepared in accordance with the soils report,
b) The utility trenches have been properly backfilled and compacted, and
c) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the
soils report."
6. Provide a letter from the soils engineer confirming that the foundation plan, grading plan
and specifications have been reviewed and that it has been determined that the
recommendations in the soils report are properly incorporated into the construction
documents.
• MISCELLANEOUS
7. Provide a note on plans stating: "New and existing buildings shall have approved
address numbers, building numbers or approved building identification placed in a
position that is plainly legible and visible from the street or road fronting the property.
These numbers shall contrast in color to .background. Numbers shall be a minimum of 4"
high with a min stroke width of½ inch." CFC Section 505.1.
8.. The jurisdiction has contracted with EsGil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for yowr project. If you have any questions regarding these plan
review items, please contact ALI SADRE, S.E. at EsGil Corporation. Thank you.
~ ... '-
' ' r CARLSBAD 16-2195
JUNE 16, 2016
[DO NOT PAY --THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURl$DIC.TION: CARLSBAD
PREPARED BY: ALI SADRE, S.E.
BUILDING ADDRESS: 2792 JAMES .DRIVE
BUILDING OCCUPANCY: R3/U; V-B/SPR.
BUILDING .AREA Valuation
PORTION ( Sq. Ft.) Multiplier
LIVING. 2974 .
GARAGE 949 ..
PATIO COVER 255
Air Conditioning
Fire Sprcinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
.
Bldg. Permit Fee by Ordin;;ince . • !
Plan Check Fee by Ordinance . • I
Type of Review: 0-Complete Review
D Repetitive Fee ~ Repeats
o Other
Cl Hourly
EsGil Fee
..
PLAN CHECK NO.: 16-2195
DATE: JUNE 16, 2016
Reg. VALUE ($)
Mod.
483,818
$1,989.261
$1,293.021
o Structural Only
$1,113.991
Comments: Jn-·aqditibfljO t~e -~~_oy~~ie.,:.~o~a~.~Jtjgn~Tf~~:Qrt§§)~.~~µe _(l_~hbu{@$~6(hrii~~
lMfGak.{re~ri review.
Sheet 1 of 1
macvalue.doc +
C,
. Gityof
Carlsbad
PLAN CHECK
REVIEW
TRANSMITTAL
Community & Economic
Development Department
1635 Faradc:1y Avenue
Carlsbad CA 92008
www.carlsbadca.gov
DATE: 08/02/2016 PROJECT NAME: BOWLING RESIDENCE PROJECT ID:CB162195
APN: 1561424800 PLAN CHECK NO: 2 SET#: 2 ADDRESS: 2792 JAMES DR
VALUATION: $483,818 SCOPE OF WORK: 2974 SF SINGLE FAMILY LOT
,.
This plan check review is complete and has been APPROVED by:
LAND DEVELOPMENT ENGINEERING DIVISION
Final Inspection by Construction Management & Inspection. Division is required: Yes !Xl No !]
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan .Check Comments have been sent to: ARLENROPER@GMAIL.COM
To determine status by one of the divisions listed below, please contact 760-602-2719.
~ LAND DEVELOPMENT I (;(lill~
~ 76().602-,2750 ~
" ,.,, ' ~-~--' . ...,.,,__ ' ·~~--' . . ' -"'"""""" .... _.,,,_,_., ___ ---~-~ r-·~1 Chris Sexton D Chris Glassen r----Greg Ryan
760-602-4624 760-602-2784 L-_! 760-602-4663
Chris.Sexton@carlsbadca.gov ·Christopher.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca.gov
D Gina Ruiz D Linda Ontiveros 7 Cindy Wong L_ 760-602-4675 760-602-2773 760-602-4662
Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov
D [Z] ValRay Nelson D Dominic Fieri
760-602-27 41 760-602-4664
ValRay.Marshall@carlsbadca.gov Dominic.Fieri@carlsbadca.gov
Remarks: **"' PLACEMENT OF IRON GATES Will ,'VEED TO BE RELOCATED OUT OF TlfE EASEMENTA,"t'D
WITN AT LEAST Oh'£ CAR LENGT/1 BETWEEN Th'£ GATES Ah'D Th'£ PUBlfC RfGNT OF WAY
,
BOWLING R~SIDENCE PLAN CHECK NO# 2 ,,
Please Read
Instructions:
l .... '
Outstanding issues are marked .!-Yl!h i_Xl • Items that conform to permit
requirements are marked with i { l or have intentionally been left blank.
SHO~
jA8£MENTS
DWG494-3A
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale.
D D North arrow
D D Existing & proposed structures
D D Existing street improvements
D D Property lines (show all dimensions)
D m Easements
CJ D Right-of-way width & adjacent streets
Show on site plan:
Show:
D D Driveway widths
D D Existing or proposed sewer lateral
D D Existing or proposed water service
D [Z] Submit on signed approved pl~ns:
DWG No. DWG 494-3A
D D Drainage patterns and proposed site elevations. Show all high points.
D D Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining
street or an approved drainage course.
D DADD THE FOLLOWING NOTE: "Finish grade will provide a minimum.positive drainage of2% to swale
5' away from building".
D D Existing & proposed slopes and topography
D Osize, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception. ·
D D Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
D W Site address
D m Assessor's parcel number
D D Legal description/lot number
CJ D For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
D D Show all existing use of SF and new proposed use of SF.
Example:•.
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
LoUMap No.: LOT 2 MAP 14517
Subdivisionrrract: CT 98-16
Reference No(s):
E-36 Page 2 of 6 REV 6/01/12
BOWLING RESIDENCE PLAN CHECK NO#. 2
N/A
DWG494-3A
2. DISCRETIONARY APPROVAL COMPLIANCE
CJ D Project does not comply with the following engineering conditions of approval for proje~t no.:
3. DEDICATION REQUIREMENTS
D D Dedication for all street rights-of-way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $ 24 000 00 , pursuant to Carlsbad Municipal Code Section 18.40.030.
CJ CJ Dedication required as follows:
4. IMPROVEMENT REQUIREMENTS
D D All needed public improvements upon and adjacent to the building site must be constructed
at time of building construction whenever the value of the construction exceeds
$120,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040.
D D Public improvements required as follows:
D D Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee, so we may prepare the necessary Neighborhood
Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit.
D D Future public improvements required as follows:
. Page 3 of6 REVS/01/12
•),
BOWLING RESIDENCE PLAN CHECK NO# 2
5. GRADING PERMIT REQUIREMENTS
GR 16-21
NEED PAD
CERTIFICATION
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
D Olnadequatei information available on site plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must be included on the plans. If no grading is proposed
write: "NO GRADING"
D [lJ Grading Permit required. NOTE: The grading pern:iit must be issued and rough grading
approval obtained prior to issuance of a building permit.
[X] D Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector The inspector will then
provide the engineering counter with a release for the building permit.
D D No grading permit required.
D D Minor Grading Permit required. See additional comments for project-specific requirements.
6. MISCELLANEOUS PERMITS
E-36
[XJ ORIGHT-0F-WAY PERMIT is required to do work in city right-of-way and/or private work
adjacent t<;> the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
D D Right-of-way permit required for:
*ANY WORK BEING DONE WITHIN THE PUBLIC RIGHT OF WAY*
Page 4 of 6 REV 6/01/12
' BOWLING RESIDENCE PLAN CHECK NO# 2
SW 16-247
E-36
7. STORM WATER
Construction Compliance
D D Project Threat Assessment Form complete.
D D Enclosed Project Threat Assessment Form incomplete.
D D Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form
and return (SW )
D D Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post-Development (SUSMP) Compliance
· D D Storm Water Standards Questionnaire.
D D Project is subject to Standard Storm Water Requirements: See.city Standard Urban
Storm Water Management Plan (SUSMP) for reference. '
D D Indicate areas of impervious surfaces (patios.walkway, etc. ) and pervious areas (landscaping).
D D Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
D Rainwater harvesting (rain barrels or cistern)
D Vegetated Roof
D Bio-retentions cell/rain garden
D Pervious pavement/pavers
D Flow-through planter/vegetat~d or rock drip line
D Vegetated swales or rock infiltration swales
0 Downspouts disconnect and discharge over landscape
D Other:
Page 5 of6 REV 6/01/12
BOWLING RESIDENCE PLAN CHECK NO# 2
8. WATER METER REVIEW
Domestic (potable) Use D D What size meter is required?
D I FYI I Where a residential unit is· required to have an automatic fire
e~inguishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity char.ge will be based on the size of the meter
necessary to meet the water use requirements. -D !FYI I For residential units the minimum size meter shall be 5/8", except where
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be¾".
9. FEES
[X]C]
·Do
DD
DD
Required fees have been entered in building permit.
Drainage fee applicable ·
Added square feet
Added square footage in last two years? Dyes D no
Permit No.
Permit No.
Project built after 1980 Dyes D no
Impervious surface > 50% Dyes D no
Impact unconstructed facility Dyes D no
Fire sprinklers required Dyes D no (is addition over 150' from center line) ·
Upgrade D yes Ono
• No fees required
10. ADDITIONAL COMMENTS
....
Attachments: [~] EnglneerlngAppllcatlon [7 Storm Water Form IJ Right-of-Way Application/Info. I. -I Reference Documents
E-36 Page 6 of6 REVG/01/12
*** Fee Calculation Worksheet ***
ENGINEERlNG DIVISION
Prepared b·y:vALRAY NELSON
Address: 2792 JAMES DR
Date: 08/02/2016 GEO DATA: LFMZ: / B&T:
Fees Update by: Date: Fees Update by:
Bldg. Permit#: CB162195
Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: SFR Sq.Ft/Units
Types of Use: Sq.Ft/Units
Types of Use:
Types of Use:
Sq.Ft.JU nits
Sq.Ft/Units
ADT CALCULATIONS: List types and square footages for all uses.
Types of Use: SFR Sq.Ft/Units
Types of Use:
Types of Use:
Types of Use:
FEES REQUIRED:
Sq.Ft/Units
Sq.Ft/Units
Sq.Ft/Units
EDU's:
EDU's:
EDU's:
EDU's:
ADT's:
ADT's:
ADT's:
ADT's:
Within CFO: DYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) lZI NO
1. PARK-IN-LIEU FEE:IZ!NW QUADRANT ONE QUADRANT OSE QUADRANT OW QUADRANT
ADT'S/UNITS: I X FEE/ADT: I =$ FM 98-16
2.TRAFFIC IMPACT FEE:
ADT'S/UNITS: I X FEE/ADT: I =$ 3150
3. BRIDGE & THOROUGHFARE FEE: ODIST.#1 ODIST.#2 ODIST.#3
(USE SANDAG)ADT'S/UNITS I X FEE/ADT: I=$ N/A
4. FACILITIES MANAGEMENT FEE ZONE: 1
ADT'S/UNITS: I X FEE/SQ.FT./UNIT: I =$ N/A
5. SEWER FEE
EDU's 1 IX FEE/EDU: 881 I =$ 881
BENEFIT AREA:
1x ,FEE/EDU: EDU's
6. DRAINAGE FEES: PLDA: OHIGH
FEE/AC:
I=$ N/A
0MEDIUM 0LOW
ACRES: 1x I=$ FM 98-16
7. POTABLE WATER FEES: PAID
UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL
PAID WM16-i
***This may not represent a comprehensive list off ees due for this project.
Please contact the Building division at (760) 602-2719 for a complete listing of fees***
CITY OF CARLSBAD
GRADING INSPECTION CHf:CKLIST
FOR PARTIAL SITE RELEASE
RECEIVED
CITY OF CARLSBAD
AUG -9 2027
PROJECT INSPECTOR: _____ JO~E ...... M ____ c _____ M----'AH""""O----N_,___ _______ DATE:. CMlfl'atffllfSION
PROJECT ID 2792 JAMES DR. PD 16-12 GRADING 'PERMIT NO. GR160021
LOTS REQUESTED FOR RELEASE: N/A ONE LOT ONLY ON THIS PERMIT
NIA = NOT APPLICABLE ~ = COMPLETE 1
O = lncom lete or unacceptable
1st 2nd.
1-----+-----1
N/A
1--~--+-----1
N/A
l-----'"----+-----1
,_.....__...,_ _ _,
1. Site access to requested lots adequate and logically grouped.
2. Site erosion control measures adequate including basins and lined
ditches installed.
3. Overall site adequate for health, safety and welfare of public.
4.
5.
Letter from Owner/Dev. requesting partial release of specific lots, pads
or bldg.
8½" x 11" site plan (attachment) showing requested lots subm_itted.
6. Compaction report from soils engineer submitted.
7. EOW certification of work done with finish pad elevations of specific lots
to be released.
8. Geologic engineer's letter if unusual geologic or subsurface conditions
exist.
9. 1 Fully functional fire hydrants within 350 feet of building combusti~les
and an all weather roads access to site is required.
10. Retaining walls installed. ·
11. Adequate progress on installation of slope irrigation and landscape.
12. Minimum 20' wide all weather road.
13. Sewer installed and available for use. IN DRIVE WAY
D
D
Partial release of grading for the above stated lots is approved for the purpo~e of building
permit issuance. Issuance of building permits is still. subject to all normal City
requirements required pursuant to the building permit process.
Partial release of the site is denied for the following reasons:
Date
Partial Site Rel Checklist-UPDATED 11/2015
j
I. t ! I l i i I l f
I E ' f
f I I ! .l,
I i i I i I I I I
Ca of
Carlsbad
PLAN CHECK
REVIEW
TRANSMITTAL
DATE: 06/09/2016 PROJECT NAME: BOWLING RESIDENCE
PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2792 JAMES DR
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID:CB162195
APN: 1561424800
VALUATION: $483,818 , SCOPE OF WORK: 2974 SF SINGLE FAMILY LOT
D This plan_ check review is complete and has been APPROVED by:
LAND DEVELOPMENT ENGINEERING DIVISION
Final Inspection by Construction Management & Inspection Division is required: Yes l~ No []
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Piease resubmit amended plans as required.
Plan Check Comments have been sent to: ARLENROPER@GMAIL.COM
To determine status by one of the divisions listed below, please contact 760-602-2719.
r,..] Chris Sexton
L 760-602-4624
Chris.Sexton@carlsbadca.gov
Chris Glassen
760-602-2784
Christopher.Glassen~carlsbadca.gov
Greg Ryan
760-602-4663
Gregory.Ryan@carlsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
D
D Linda Ontiveros
760-602-2773
-Linda;0ntiveros@carl~badca.gov
ValRay Nelson
760-602-27 41
ValRay.Marshall@carlsbadca.gov
Cindy Wong
760-602-4662
Cynthia.Wong@carlsbadca.gov
Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
Remarks: *** PLACEMENT OF IRON GATES WILL NEED TO BE RELOCATED OUT OF THE EASEMENT AND
WITH AT LEAST ONE CAR LENGTH BETWEEN THE GATES AND THE PUBLIC RIGHT OF WAY
BOWLIN~ RESIDENCE PLAN CHECK NO# 1
Please Read
Instructions:
Outstanding iss1Jes are marked with [X! . Items that conform to permit
requirements are marked with 0 or have intentionally been left blank.
SLIP SHEET
CITY SIGNED
'APPROVED
SHOW
EASEMENTS
DWG494-3A
1. SITE PLAN
Provide a fµlly dimensioned site plan drawn to scale. Show:
D
D
D
D
[Kl
D
D North arrow CJ Existing & proposed structures
c::J Existing street improvements
D Property lihes (show all dimensions)
0Easements
D Right-of-way width & adjacent streets
Show on site plan:
D
D
D
.[XI
D Driveway widths
D Existing or proposed sewer lateral
D Existing or proposed water service
D Submit on signed approved plans:
DWG No. DWG 494-3A
D D Drainage patterns and proposed site elevations. Show all high points.
D · CJ Building pad surface dr-ainage must maintain a minimum slope of one percent towards an adjoining
street or an approved drainage course.
D LJADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
5' away from building".
D D Existing & proposed slopes and topqgraphy
D LJSize, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
CJ D Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
D W Site address
D m Assessor's parcel number
· CJ D Legal description/lot number
D D For commercial/industrial buildings and tenant improvement projects, include: total building
squar~ footage with the square footage for each different use, existing sewer permits
st:iowing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
D D Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.: LOT 2 MAP 14517
Subdivision/Tract: tr 98-16
Reference No(s):
E-36 Page 2 of 6 REV 6/01/12
BOWLING RESIDENCE PLAN CHECK NO# 1
N/A
DWG 494-,3A
E-36
2. DISCRETIONARY APPROVAL COMPLIANCE
[:J D Project does not comply with the following engineering conditions of approval for project no.:
3. DEDICATION REQUIREMENTS
D D Dedication for all street rights-of-way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $ 24 000,00 , pursuant to Carlsbad Municipal Code Section 18.40.030.
D D Dedication required as follows:
4. IMPROVEMENT REQUIREMENTS I .
D DAIi needed public improvements upon and adjacent to the building site must be constructed
-at time of building construction whenever the value of the construction exceeds
$120,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040.
D D Public improvements required as follows:
D D Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit~ recent.property title report or current grant
deed on the property and processing fee, so we may prepare the necessary Neighborhood
Improvement Agre~ment. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit. ·
D D Future public improvements required as follows:
Page 3 of-6 REV6/01/12
BOWLING RESIDENCE PLAN CHECK NO# 1
GR 16-21
E-36
5. GRADING PERMIT REQUIREMENTS
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
D Olnadequate information available on site plan to make a determination on grading
· requirements. Include at::curate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must .be included on the plans. If no grading is proposed
write: "NO GRADING"
[ZJ D Grading Permit required. NOTE: . The. grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit.
[X} D Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector The inspector will then
provide the engineering counter with a release for the building permit.
D D No grading permit required.
D D Minor Grading Permit required. See additionc;1I comments for project-specific requirements.
6. MISCELLANEOUS PERMITS
[X] ORIGHT-0F-WAY PERMIT is requlred to do work in city right-of-way and/or private work
adjacent to the public right-of-way .. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
D O Right-of-way permit required for:
*ANY WORK BEING DONE WITHIN THE PUBLIC RIGHT OF WAY*
Page 4 ofS REV 6/01/12
BOWLING RESIDENCE PLAN CHECK NO# 1
SW 16-247
E-36
7. STORM WATER
Construction Compliance
D CJ Project Threat Assessment Form complete.
D · CJ Enclosed Project Threat Assessment Form incomplete.
D D Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form
and return (SW )
D CJ Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post-Development (SUSMP) Compliance
D D Storm Water Standards Questionnaire.
D D Project is subject to Standard Storm Water Requirements. See city Standard Urban
' Storm Water Management Plan (SUSMP) for reference.
D D Indicate areas of impervious surfaces (patios.walkway, etc. ) and pervious areas (landscaping).
D D Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
D Rainwater harvesting (rain barrels or cistern)
D Vegetated Roof
D Bio-retentions cell/raih garden ·
D Pervious pavement/p~vers
D Flow-through planter/vegetated or rock drip line
D Vegetated swales or rock infiltration swales
D Downspouts disconnect and discharge over landscape
D Other:
Page 5 of 6 REV 6/01/12
BOWLING RESIDENCE PLAN CHECK NO# 1
8. WATER METER REVIEW
INDICATED
WHAT SIZE
METER WILL
BE REQUIRED
Domestic (potable) Use 00 D What size meter is required?
CJ I FXI I Where a residential unit is required to have an automatic fire
exting1,1ishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements. D !FYI I For residential units the minimum size meter shall be 5/8", except where
the residential unit is .larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be¾".
9. FEES
000
DD
Required fees have been entered in_ building permit.
Drainage fee applicable.
Added ss:iuare feet
Added square footage in last two years? Dyes D no
Permit No.
Permit Na..
Project built after 1980 Dyes D no
Impervious surface > 50% Dyes D no
Impact unconstructed facility Dyes D no
DD Fire sprinklers required Dyes D no (ls addition over 150' from center line)
Upgrade Dyes Ono
oo· No fees required
10. ADDITIONAL COMMENTS
Attachments: CJ EnglneerlngAppllcatlon [_1 Storm Water Form LJ Right-of-Way Application/Info. [7 Reference Documents
E-36 Page6 of 6 REV 6/01/12
' '
*** Fee Calculation Worksheet***
ENGINEERING DIVI.SION
Prepared by: Date: GEO DATA: LFMZ: / B& T:
Address: Bldg. Permit#:
Fees Update by: Date: Fees Update by: Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq.Ft./Units
Types of Use:
Types of Use:
Types of Use:
Sq.Ft.JU nits
Sq.Ft./Units
. Sq.Ft./Units
. ADT CALCULATIONS: List types and sq1,1are footages for all uses.
Types of Use: Sq.Ft./Units
Types of Use:
Types of Use:
Types of Use:
FEES REQUIRED:
Sq:Ft./Units
Sq.Ft./Units
Sq.Ft./Units
EDU's:
EDU's:
EDU's:
EDU's:
ADT's:
ADT's:
ADT's:
ADT's:
Within CFD;OYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) [Z] NO
1. PARK-IN-LIEU FEE:0NW QUADRANT ONE QUADRANT 0SE QUADRANT OW QUADRANT
ADT'S/UNITS: I X FEE/ADT: I =$
2.TRAFFIC IMPACT FEE:
ADT'S/UNITS: I X FEE/ADT: I=$
3'. BRIDGE & THOROUGHFARE FEE: ODIST.#1 ODIST.#2 DDIST.#3
(USE SANDAG)ADT'S/UNITS I X FEE/ADT: I=$
4. FACILITIES MANAGEMENT FEE ZONE:
ADT'S/UNITS: I X FEE/SQ.FT./UNIT: I=$
5. SEWER FEE
EDU's IX FEE/EDU: I=$
BENEFIT AREA: ,
FEE/EDU: ~DU's
6. DAAINAGE FEES:
1x
PLDA: OHIGH
FEE/AC:
I=$
0MEDIUM 0LOW
ACRES:
7. POTABLE WATER FEES:
UNITS CODE
1x I=$
CONN. FEE METER FEE SDCWA FEE
***This may not represent a comprehensive list of fees due for this project.
TOTAL
Please contact the Building division at (760) 602·2719 for a complete listing of fees***
, I
STORM WATER.COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
CB /p4/lf
SW/.k12-~
STORM WATER POLLUTION PREVENTION NOTES BEST MANAGEMENT PRACTICES (BMP) SE~ECTION TABLE
1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE
iWAILABLE ON SITE TO FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN
IS EMINENT.
2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION
CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION
OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING
RAINFALL.
3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY
INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE.
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE
AT THE END OF EACH WORKING DAY WHEN THE FIVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT
{ 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL
5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER
PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST
BE INSTALLED AND MAINTAINED.
7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY
REGULATIONS.
!l 0 ::,;
Best Management Practice* -'<I
(BMP) Description ~ ., .,
~ ~ ~
CASQA Designation ~ .... I
Construction Activity fil
!,rodin<1/Soll Disturbance
rrrenching/Excovotion
\I' Stbckoilina
Drillina/Borlna
1/Concrete/Asoholt .Sawcutting
V Concrete Flotwork
P.ovina
lf:onduit/Pioe Installation
V .!!.ucco/Mortor Work
. J Waste Disoosal
'..Staqlna /l av Down Area
linuioment Maintenance and FuelinQ
, :Hll,ardous Substance Use/Storaqe
iOewatering
V Site Access Across . Dirt
Other (list):
Erosion Control BMPs
,-g ~ "' a. c, "o 0 :c ., .. ., ,= u ""' ~ ., '3 .,,., u ii :::E Cc, ~ "O 0 ., . § :e-~ 0 g. "O -i ce 'U) .,i WO in
00 a> ,; I I ' hl i)tl fil IX
·v V
Sediment Control BMPs Tracking Control BMPs
C ~ -0 ~ C u 0 E ~ .5 .5 "' L ., .E. .!!:?· :s ~ 18 ] a, a. t: ., 0 .5 (.)~ E ., "' ""' a, eg 0 'is 0 ~.5 'g~ ]f C a, c> 0:.::, "' 1,~ C ~Jg ~ 1 ,g ~i kl :g ~ ·18 .. eU Jj 0 ~ in~ ind: V) C (/)"' ... IO '° .... ; 0 ~ ~ ~ ~ I· 'T l/ ' !Jj, 1b! f!=j f!=
... , v V iY
I'
"
Non.Storm Water Waste Management and Materials Management BMPs Pollution Co.ntrol BMPs
C -0 -:;, C "O, C
"' 0 E ., '"0 C "' C E C ~ 0 .2 'E .e-., 0 {! 1 ~ ~ ~ ~ "' -~ o· -~ 0 !l C
"O ~ gi. 0 ] 25 =-=-iL,, "O ., ~ C ::, ::,; .,Iii §g 0"' .!! 1l E jsE ~~ E-t;n+l ., ~-~ :g 8. i ci. ,., .. -0 .,
·i ~ :c ~ a. _g "' L 0, .e~ :2 g oO _ ... ~ i:=c NC :i&: ~o ~ 8'.8 "-a.o oo O·O a. :>;Cl) ::,; C/lU Cl):>; :C::>i
,,, .... 00 ' N 't")' ... IO '° ;i; I I J, I I I I I (/) (/) ii i i ii i ii z z z z
,. • ~ v I V V V
j
I • f>4_
\ I -I .. . ,'V I r ., , ,.., " I V V IV Ir ..., /
J/
Instructions: .
1. Check the box to the left of all applicable construction activity (first colu.mn) expected to occur durin·g construction.
2. "Located along the top of the BMP Tobie is a list of BMP's with lt'.s corresponding California Stormwater. Quality Association {CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column.
3. Refer to the CASQA construction handbook for informatiqn and details of the ch~sen BMPs and how to apply them to the project.
OWNER'S CERTIFICATE:
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION
ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID
THE MOBiUZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO
AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION
RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT All TIMES,
COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP
THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES ~
UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED B
BY THE CITY OF CARLSBAD , JY'.,,t-v._A l) ,/{)B //...(' ~ f?tlp-(.,? I
OWNERS 4,(lz/1,t,
E-29
SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE
ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN.
SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE
EROSION CONTROL PLAN.
-BMP's are subject to field inspection-
Page 1 of 1
PROJECT INFOR~TION
Site Address:t,;7 Z. q7/,wl!ii:., /)fZ.
Assessor's Parcel Number/S&-/L./l.-4 8
Emergency. Contact: u ~ r:J. _ / )
~
Construction Threat to Storm Water Quality
(Check Box)
0 MEDIUM '8-J.OW
-
{!
~'ii
,.e? ~ E"' uo ·:s 6 U::>i
00 I i
~
,v
f
.J ., ,.,
't~/3>
REV 02/16
\
-BMP's are subje~t to field inspection-\
• I <'
XX O )(X XX XX ;.':;,.',.~]f!'N~,\ \
-----j ~ SCALE:
l
sax)NDDWEil.lJIC :\ Ul8T PA/IIONG Q~~
PROPEHfY LJNE
SILT Ff.NCE
FIBER ROLL
PRESERVAITON OF EXISITNG
INLET PROTECITON
GRAVEL B<!G 8ERM/B<IRRIER
DIRECITON/COURSE OF FLOW
HYDRAUUC MULCH/HYDROSEED
STA8/UZED CONSTRUCITON ENTRANCE
MATERIALS DELJVERY ANO STORAGE AREA
TEMPORARY TRASH/SOUD WASTE
HAZARDOUS AND CONCRETE
WASTE MANAGEMENT
SANITA!iY WASTE
(PORTABLE TOILET)
711
LEGEND
•DWG.NO. SYMBOL
N45'45'45"W
SE-1 -0---0--
SE-5 -X-X-X-X-
EC-2 I Z Z 2 2 7 Z 2 2 I
SE-10 ~
SE-6 CX::X:::X:::X:: --
EC-1.EC-4 ™
TR-I ffllll~ll~ffl
lt?H I WM-I I
WM-5 I WM-5 I
WM-6, WM-8 I :=~ I
WM-9 I WM-91
•STAND,4RD DRAWINGS (SE-5, WM-5, ETC.} cAN BE FOUND AT THE
CALIFORNIA STORMWATER Ql.blLJTY ASSOC/AITON (CASQA) WEBSITE: http:/ ,f www.cabmphandbooks.com/
.9_UANTITY
., ___________________________________________ _
_ (Cttyof
Qrrlsbad
DETERMINATION OF
PROJECT'S SWPPP
TIERLEVELANDCONSTRUCTION
THREAT LEVEL
E-32
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
I'm applying f9r: D 9rac;f ing ~ermit A7suilding Pe.rmit D Right-of-way permit D Other
Project Na~~~-06'~ Address:2, _ . . ·
Project ID: __.·--.-=-r--DWG #/CB# ___ .,..,,.., __ _
APN/$:l<t.2, ..... 'ff Disturbed Area: _ __._i-+-y ___ Ac
Section 1: Determination of Project's SWPPP Tier Level SWPPP
(Check applicable criteria and cjrcle the corresponding SWPPP Tier Level, then go to section 2) · Tier L: :'
Exem12t -No Threat Project Assessment Criteria
My project is in a· category of permit types exempt from City Construction SWPPP requirements. Provided
· no $ignificant grading proposed, pursuant to Table1, section 3.2.2 of Storm Water Standards, the
following __ permits are exempt from SWPPP requirements: Exempt -
}> Electrical· >-Patio }>
, Mobile Home }> Plumbin~ }> Spa (Factory-Made)
}> Fire Sprinkler }> Mechanical }> Re-Roofing }> Sign }> Roof-Mounted Solar Array
Tier 3-Significant Threat Assessment Criteria..,.. (See Construction General Permit (CGP) Section I.B)*
D My project includes construction or demolitio,n activity that results in a land disturbance of equal to or
greater than one acre including but not limited to clear-ing, grading; grubbing or excavation; or,
D My project includes construction activity that results in land disturbance of less than one acre but the
construction activity is part of a larger common plan of development or the sale of one or more acres
of disturbed land surface or,
D My Project is associated with construction activity related to residential, commercial, or industrial Tier3
development on lands currently used for agriculture; or
D My project is associated with construction activity associated with Linear Underground/overhead
Projects (LUP) including but not limite.d to those activities necessary for installation of underground
and overhead linear facilities (e.g. conduits, substructures, pipelines, towers, poles, cables, wire,
towers, poles, ca~les, wires, connectors, switching, regulating and transforming equipment and
associated ancillawfacilities) and include but not limited to underground utility mark out, potholing,
concrete and asphalt cutting and removal,· trenching, excavation, boring and drilling, access road,
tower footings/foundation, pavement repair or replacement, stockpile/borrow locations.
D Other per CGP
Tier 2-Moderate Threat Assessment Criteria: My project does not meet any of the Significant Threat
Assessment Criteria described above and meets one or more of the following criteria:
D Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the
Carlsbad Municipal Code); or,
D Project will result in 2,500 square feet 6r more of soils disturban~e including any associated
construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance
areas and project meets one or more of the additional following criteria: Tier2
• located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or,
• disturbed area is ·Iocated on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or
• disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or
watercourse; and/or
• construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1
through Apr. 30).
TiA"" 1-Low Threat Assessment Criteria
~ My project does not meet any of the Significant or Moderate Threat criteria above, is not an exempt
· permit type per above and the project meets one or more of the following criteria: Tier 1 .. results in some soil disturbance; and/or
• includes outdoor construction activities (such as roof framing, saw cutting, equipment washing,
material stockpiling, vehicle fueling, waste stockpii'ing) ,--* Items listed are excerpt from CGP. CGP governs criteria for triggers for Tier 3 SWPPP. Developer/owner shall confirm coverage
under the current CGP and any amendments, revisions and reissµance·thereof.
E-32 Page 1 of2 Rev. 2/16/16
SWPPP Section 2: iDetermination of Project's Construction Threat Level
Tier (Check applicable criteria under the Tier Level as determined in section 1, circle Construction
Level the corresponding Construction Threat Level, then complete the Threat Level
signature block below)
Exempt -Not Applicable -Exempt
Tier 3 -High Construction Threat Assessment Criteria: Mt Project meets one or more of the'
following:
CJ Project site is 50 acr~s or more and grading will occur during the rainy season
CJ Project site is located within the Buena Vista or Agua Hedionda Lagoon watershed,
inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly
to an ESA High
CJ Soil at site is moderately to highly erosive (defined as having a predominance of soils Tier3 with USDA-NRCS Erosion factors kf greater than or equal to 0.4)
CJ Site slope is 5 to 1 or steeper
. ----. CJ Construction is initiated during the rainy season or will extend into the rainy season (Oct. ---·1 :. April 30). . -
CJ Owner/contractor received a Storm Water Notice of Violation within past two years
Tier 3 -Medium Construction Threat Assessment Criteria Medium CJ All projects not meetimg Tier 3 High Construction Threat Assessment Criteria
Tier 2 -High Construction Threat Assessment Criteria: Mt Ptoject meets one or more of
the following:
CJ Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or
within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an
ESA
CJ Soil at site is moderately to highly erosive (defined as having a predominance of soils High
Tier2
with USDA-NRCS Erosion factors kr greater than or equal to 0.4)
CJ Site slope is 5 to 1 or steeper
CJ Construction is initiated during the rainy season or will extend into the rainy season (Oct.
1-Apr. 30).
CJ Owner/contractor received a Storm Water Notice of Violation within past two years
CJ Site results in 10,000 sq. ft. or more of soil disturbance
Tier 2 -Medium Construction Threat Assessment Criteria Medium CJ My project does not meet Tier 2 High Threat Assessment Criteria listed above
Tier 1 -Medium Construction Threat Assessment Criteria: Mt Project meets one or more
of the following:
· CJ Owner/contractor received a Storm Water Notice of Violation within past two years Medium
Tier 1
... Q_ Site result~ in 5Q0_sq. ft. or more 9f soil. di§,turl;>JtnQ~ _ _ ____
CJ Constructioi:, will be initiated during the rainy season or will extend into the rainy season
(Oct.1-April 30)
Tier 1 -Low Construction Threat Assessment Criteria Low CJ My project does not meet Tier 1 Medium Threat Assessment Criteria listed above
I certify to the best of my knowledge that the above statements are true and cqrrect. I will prepare and submit an appropriate tier level SWPPP as determined above
prepared in accordance with the City SWPPP Manual. I understand and acknowledge that I must adhere to and comply with the storm water best management
practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards at all times during construction activities for the permit type(s) checked above.
The City Engineer/Building Official may authorize minor variances from the Construction Threat Assessment Criteria in special circumstances where it can be shown
that a lesser or higher SWPPP Tier Level is warranted.
Owner/0wner's Authorized Agent Name:
/5 /;$t1(_ i:>6rl.-> r
• 6G--....,u/" vL
Tit!>:::,~ S-1 ,,o,.,, rC"(
$6"<!.. -
Page 2 of 2
City Concurrence: Yes No
(For City Use Only)
By:
Date:
Project ID:
Rev. 2/16/16
l''
~--
«~ ~ CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.1mv
DATE: 7/22/2016 PROJECT NAME: SINGLE FAMILY RESIDENCE PROJECT ID:
PLAN CHECK NO: CB162195 SET#: 2 ADDRESS: 2792 JAMES DR APN:
~ This plan check review is complete and has been APPROVED by the
Planning Division.
By: Veronica Morones
A Final Inspection by the Planning Division is required D Yes [gl No
You may also have corrections from one or more of the divisions listed below.
Approval' from these divisions_ may be required prior .to the issuance of a building
permit. Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are
listed on the attached checklist. Please resubmit amended plans as
required.
Plan Check Comments have been sent to: arlenroper@gmail.com
For questions or clarifications on the attached checklist please contact the following reviewer as
marked:
" .. . ~ ,. . ,. . .,, ' --.
·PLANNIN-G ENGINEERING -· '· · FIRE PREVENTION . · . ' .-· ,,. .·' " ' 7£?()-602-4610 760-6O2~27SO veo-eo;;Mes,s -• . ' ...
,,._ ·--.. .. , . . ~
D Chris Sexton D Chris Glassen D Greg Ryan
760-602-4624 760-602-2784 760-602-4663
Chris.Sexton@carlsbadca.gov Christogher.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca.gov
D Gina Ruiz D ValRay Marshall D Cindy Wong
760-602-4675 760-602-2741 760-602-4662
Gina.Ruiz@carlsbadca.gov ValRay.Marshall@carlsbadca.gov Cynthia.Wong@carlsbadca.gov
~ Veronica Morones D Linda Ontiveros D Dominic Fieri
760-602-4619 · 760-602-2773 760-602-4664
Veronica.Morones@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov
Remarks: -PENDING APPROVAL OF GRADING PERMIT D'NG 494 3A;DWG 494-3A
approved; LOW WALL DENOTED IN FRONT OF HOME, BUT IS OUTSIDE FYSB REQ; HERB
P-28 Page 1 of4 07/11
'' >
~ W CITY OF
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e:ov CARLSBAD
REVIEW#:
1 2 3
P-28
GARDEN SHOWN IS UNDER 5OOSF; INTERIOR FIREPLACE INTRUDES SYSB BY 1.5'. INLIEU
FEE AND DISTURBED HMP FEES ASSESSED UNDER CB162195.
Plan Check No. CB162195 Address 2792 JAMES DR Date 7/22/2016 Review# 2
Planner Veronica Morones Phone {760) 602-4619
APN:
Type of Project & Use: SINGLE FAMILY RESIDENCE Net Project Density: DU/AC
Zoning: R-1 General Plan: R-4 Facilities Management Zone: 1
CFD (in/out) #_Date of participation: __ Remaining net dev acres: __
(For non-residential development: Type of land use created by this permit: __ )
Legend: ·!XI· Item Complete D Item Incomplete -Needs your action
Environmental Review Required: YES O NO O TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Actien Required:
APPROVAL/RESO. NO. __ · DATE
PROJECT NO.
OTHER RELATED CASES:
YES O NO~ TYPE __
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES O NO 181
CA Coastal Commis~ion Authority? YES D NO 181
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite
103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt): N/A
H.abitat Management Plan ...,. FEE ASSESSED $904.80
Data Entry Completed? YES ~ NO O .
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habit~t
Type impacted/taken, UPDATE!)
lnclusion..,.ry Hous,ng Fee required~ Fl;E ASSES$EO $45·15.00
YES~ NOD
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Page 2 of4 07/11
~ «i~ W CITY OF
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov CARLSBAD
Site Plan:
l8l l8l D
P-28
Data Entry Completed? YES l8J NO 0
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing
YIN, Enter Fee, UPDATE!)
Housing Tracking Form (form P-20) completed: YES D NO D N/A l8l
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 -Neighborhood Architectural Design Gu_idelines
1. Applicability: YES O NO l8l
2. Project complies:· YES D NOD
Zoning:
1. Setbacks: R-1
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required 20' Shown 20'
Required 7'6" Shown 7'6"
Required __ Shown __
Required .1.[ Shown 15'1"
Required ___ Shown __
2. Accessory structure setbacks:
Front: Required __ Shown __
Interior Side: Required __ Shown __
Street Side: Required __ Shown __
Rear: Required __ Shown_·_
Structure separation: Required __ Shown __
3. Lot Coverage:
Required 40% MAX Shown 33%
4. Height:
Required 30' MAX@>3:12 Shown 21'11"@5.5:12
5. Parking: Spaces Required 2-CAR GARAGE + 1 FOR PAN HANDLE Shown 2-
CAR GARAGE (22'X32') AND 1 EXTERIOR (NOT IN FYSB)
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces
6. Floor Area Ratio:
Required __ Shown __
Required __ Shown·_._
Page 3 of4 07/11
«f~ W CITY OF
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610.
www.carlsbadca.eov CARLSBAD
D~D Additional Comments:
1. PLEASE PROVIDE DETAILS FOR THE OUTDOOR FIREPLACE SHOWN ON PLANS.
2. PLEASE SHOW HEIGHT OF FOUNTAIN SHO\A.'N IN SYSB, NTE &' .
3. PLEASE SPECIFY 'l!HAT THE 4' SETBACK IS IN REGARDS TO SHOWN ON SHT
A1 .1 IN THE FRONT YARD (FLATWORK, ETC)
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER V.Morones DATE 7/22/2016
P-28 Page 4 of4 07/11
~ «-~~ ¥ t'JTY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
{760) 602-4610
www.carlsbadca.1mv
DATE: 6/9/2016 PROJECT NAME: SINGLE FAMILY RESIDENCE PROJECT ID:
PLAN CHECK NO: CB162195 SET#: 1 ADDRESS: 2792 JAMES DR APN:
D This plan check review is complete and has been APPROVED by the
Planning Division.
By: Veronica Morones
A Final Inspection by the Planning Division is required D Yes , ~ No
You may also have correcti.ons from one or more of the divisions listed below.
Approval from these divisions may be required prior to the issuance of a building
permit. Resubmitted plans should include corrections from all divisions.
[gl This plan check review is NOT COMPLETE. Items missing or incorrect are
listed on the attached checklist. Please resubmit amended plans as
required.
Plan Check Comments have been sent to: arlenroper@gmail.com
For questions or clarifications on the attached checklist please cont_act the following reviewer as
marked:
-... -· .. -·--" . ---. ~ ' Pl.ANNING EN'GINESRIN.G ' :FIR;E:PREY.ENT.i.O.N · w~
760-602-4610 ' 760-602~4(;,65 . 76()..602-2750· ., "
"
. .. . .. .. .. ..... ... .,, .. ~.-'' .. , _ _, .. -.. ' , . ,., , . ~ -· ·-. -. , ' .
D Chris Sexton D Chris Glassen D Greg Ryan
760-602-4624 760-602-2784 760-602-4663
Chris.Sexton@carlsbadca.~ov Christogher.Glassen@carlsbadca.gov Grego[Y.Ry:an@carlsbadca.gov
D Gina Ruiz D ValRay Marshall D Cindy Wong
760-602-4675 760-602-27 41 760-602-4662
Gina.Ruiz@carlsbadca.gov ValRay:.Marshall@carlsbadca.gov Cy:nthia.Wong@carlsbadca.gov
~ Veronica Morones D Linda Ontiveros D Dominic Fieri
760-602-4619 760-602-2773 760-602-4664
Veronica.Morones@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov
· Remarks: -,PENDING APPROVAL ·Qi= GRAOiNG P~RMt:r bW<i494:.3A; LOW WALL
DENOTED IN FRONT OF HOME, BUT IS OUTSIDE FYs·s REQ; HER.B GARDEN SHOWN IS
P-28 Page 1 of4 07/11
'
p
~/
«~ ~ CITY OF
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www .carlsbadca.1mv CARLSBAD
REVIEW#:
1 2 3
IX! D D
IX! D D
IX! DD
[gl DD
IX! D D
P-28
UNDER SOOSF; INTERIOR FIREPLACE INTRUDES SYSB BY 1.5'. INLIEU FEE AND DISTURBED
HMP FEES ASSESSED UNDER CB162195.
Plan Check No. CB162195 Address 2792 JAMES DR Date 6/9/2016 Review# 1
Planner Veronica Morones Phone (760) 602-4619
APN:
Type of Project & Use: SINGLE FAMILY RESIDENCE Net Project Density: DU/AC
Zoning: R-1 General Plan: R-4 Facilities Management Zone: 1
CFD (in/out) #_Date of participation: __ Remaining net dev acres: __
(For non-residential' development: Type of land use created by this permit: __ )
Legend: [g] Item Complete D Item .lncpm_plete -Needs your action
Environmental Review Required: YES D NO D TYPE
DATE OF COMPLETION:
Compliance with cor:1ditions of approval? If not, state conditions which require action.
Conditions of Approval: ·
Discretionary Action Required: YES D NO IX! TYPE __
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Asse$sment/Compliance
Project site located in Coastal Zone? YES O NO .IX!.
CA Coastal Commission Authority? YES D NO .IX!.
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite
103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt): N/A
Habitat Management Plan -J;E~ A$$ESSED $'904.80
Data Entry Completed? YES IX! NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat
Type impacted/taken; UPDATE!)
lnclusion~ry Housin_g Fee required: FE!;: ASSESSED $4515;00
YES IX! NOD
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Page 2 of4 07/11
«'~ ~ CITY OF
PLANNING DIVISION
BUILDI.NG PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov CARLSBAD
~DD
Site Plan:
~DD
lg] DD
~DD
~DD
~DD
!81 D D·
~DD
~DD
~DD
P-28
Data Entry Completed? YES ~ NO D
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing
Y/N, Enter Fee, UPDATE!)
Housing Tracking Form (form P-20) completed: YES D NO D N/A ~
Provide a fully dimensional $ite plan drawn to scale. Show: North arrow, property li'nes,
easements, existing and proposed structures, streets, existing street improvements,. right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES D NO ~
2. Project complies: YES D NOD
Zoning:
1. Setbacks: R-1
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required 20' Shown 20'
Required 7'6" Shown 7'6"
Required __ Shown __
Required 1[ Shown 15'1"
Required_-_Shown __
2. Accessory structure setbacks:
Front: Required __ Shown __ _
Interior Side: Required _· ._ Shown __
Street Side: Required __ Shown __
Rear: Required_· _ Shown __
Structure separation: Required __ Shown_·_-_
3. Lot Coverage:
Required 40% MAX Shown 33%
4. Height:
Required 30' MAX@ >3:12 Shown 21'11"@ 5.5:12
5. Parking: Spaces Required 2-CAR GARAGE+ 1 FOR PAN HANDLE Shown 2-
CAR GARAGE (22'X32') AND 1 EXTERIOR {NOT IN FYSB)
(breakdown by uses for commercial arid industrial projects required)
Residential Guest Spaces Required ___ Shown __
6. Floor Area Ratio: Req1,1ired __ Shown __
Page 3 of4 07/11
~ «~~ W CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
ODO Additional -Comments:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602~4610
· www.carlsbadca.eov
~: ·~t~::~ :~g~~~~E::~::i~N~lTNo~:g~i~:~~~B~~~~ ~~OWN O.N PLANS.
3. PLEASE SPECIFY WHAT tHE 4' SETBACK.I$ IN REGARDS TO-SHOWN ON SHT
A.1.1 IN THE FRONT YARD (FLATWORK; ETC)
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
P-28 Page 4 of4 07/11
City o·f Carlsbad Valuation Worksheet Building Division
Permit No:
[----"--·---~.. '""'--"·---. '" -··----~ -7· ;,,~L. .. ~ > · -·~ .'A .. !!!! ', , . ~> -·_, -~tstorrarcef~. , -· .. -~---_-, ._. ~'.';_, -: :: 5>;s,i::. ,) :~>~•:d
1:., ""'"\ _ t~QtWQtfi -•·
,, --.• ~,-' Muttip1fer : : .{ :':.~,> ,; -v,M.ti~~-.. , ,: '•,,,'
'~ ' '" ,,
,1','-.' '''):" __
SFD and Duplexes 2,974 $139.52 $414,932.48
Residential Additions $166.81 $0.00
Remodels / Lofts $45.78 $0.00
Apartments & Multi-family $124.35 $0.00
Garages/Sunrooms/Solariums 949 $36.40 $34,543.60
Patio/Porell 255 $12.13 $3,093.15
~nclosed Patjo $19.71 $0.00
Decks/Balcqnies/Stairs $19.71 $0.00
Retaining Walls, concrete,masonry $24.26 $0.00
,,
Pools/Spas-Gunite $51.56 $0.00
Tl/Stores, Offices $45.78 $0.00
Tl/Medical, restaurant, H occupanc;:i~s $63.70 $0.00
Photovoltaic Systems/# of panels $400.00 $0.00
$0.00
$0.00 -$0.00
$0.00 $0.00
$0.00 $0.00
Fire Sprinkler System 3,923 $3.94 $15,456.62
Air Conditioning -commercial $6.37 $0.00
Air Conc;litionirig -residential 2,974 $5.31 $15,791.94
Fireplace/ concrete, masonry $4,883.11 $0.00
Fireplace/ prefabricated Metal $3,319.61 $0.00
$0.00
$0.00
TOTAL $483,817.79
Valuation: $483,818 CFO· Comm/Res (C/R): R la· Yes (PFF=l.82%) ltf No (PFF = 3.5%)
Building Fee $1,989.26 Land Use:
Plan Check Fee $1,392.48 Density:
Strong Motion Fee $48.00 Improve. Area:
Green Bldg. Stand. Fee $16.00 Fiscal Year:
Green Bldg PC Fee $163.00 Annex. Year:
Factor: License T~x/PFF $16,933.62 CREDITS License Tax/Pf F (in CFO) $8,805.48 PFF and/or CFD
CFO Explanation:
1st hour of Plan CheckFire Expedite
Plumbing TBO
Mechanical TBO
Electrical TBD
4020 30th St. San Diego, CA 92104
Evan Coles, P.E. (858) 376-7734
evan@simplystrongeng.com
RECEl\!ED
JUN O 7 2016
CITY OF CARLSBAD
BUILDING OlViSION
STRUCTURAL CALCULATIONS
Bowling Residence
2792 James DR, Carlsbad, CA 92006
05/27 /16 : Project # 16-072
DIGITALLY SIGNED
Table of Contents
Design Criteria & Loads .................................................. 1
Gravity Analysis & Design .............................................. 2-4
Lateral Analysis & Design .............................................. 5-12
Foundation Analysis & Design ..................................... 12
Design Criteria
Building Code:
Concrete:
Masonry:
Mortar:
Grout:
Reinforcing Steel:
Structural Steel:
Bolting:
Welding:
Wood:
Soil:
Design Loads
SIMPLY STRONG
E:NGINEERJNG
2012 IBC/2013 CBC -ASCE / SEI 7-10
ACI 318-11 [f c = 2500 psi -No Special Inspection Req. 'd (U.N.O.)]
TMS 402-11/ACI 530-11 [Normal Wt.-ASTM C90-fm=1500 psi-Spec. Insp. Req.'d]
ASTM C270 [f c = 1800 psi Type S]
ASTM C476 [f c = 2000 psi]
ASTM A615 [Fy = 40 ksi For #4 Bars & Smaller/ Fy = 60 ksi For #5 Bars & Larger]
AISC 360-10, 14th Edition
W Shapes (I Beams):
HSS Shapes (Rect.):
HSS Shapes (Round):
Pipe Shapes:
All other steel:
ASTM A992, High Strength, Low Alloy, Fy = 50 ksi
ASTM A500, Carbon Steel, Fy = 46 ksi
ASTM A500, Carbon Steel, Fy = 42 ksi
ASTM A53, Grade B, Carbon Steel, Fy = 35 ksi
ASTM A36, Fy = 36 ksi
A307 / A325-N / A490-N (Single Plate Shear Conn.)
E70 Series Typ. (E90 Series for A615 Grade 60 Reinforcing Bars)
Shop welding to be done in an approved fabricator's shop.
Field welding to have continuous Special Inspection.
NDS-12
Geotechnical Report By:
Allowable Bearing Pressure =
Lateral Bearing Pressure =
Active Pressure =
At-rest Pressure =
Coefficient of Friction =
Lateral Seismic Pressure =
Project#:
Date:
Coast Geotechnical
1700 psf
N/A psf/ft
38 psf/ft
60 psf/ft
0.3 (Table 1806.2)
N/A
W.O. U-659416
5/23/2016
Page 1 of 12
05/27/16
Roofing 1 psf Roofing 2 Ext. wall psf
DL !C'.t;>Ht;re1:e_]l[;_1 .. ___ .. ___ t_o._'O'_l
Plywood 1.5
Rafters or Trusses 3.5
Insulation 1.5
Drywall 2.5
Electrical/Mech./Misc. 1.0
Other
Total DL
LL Residential
Total Load
20
20
40
DL I · ;. C, ' .; ' ,~, ' • ; ' '
Plywood
Rafters or Trusses
Insulation
Drywall
Electrical/Mech./Misc.
Other
Total DL
LL Residential
Total Load
DL rstuce0+ 1. :~.,;;;";·; .. ~ ~ % ;.z.~:19..:9:;:g
2x4 Studs @ 16110.c. 1.0
Drywall 2.5
Insulation 1.5
Misc. 1.0
Other
Total Load 16
Int. wall psf
DL fQ.~hl,~:Y~I~~~~:5:.:.~Lir~; d
2x4 Studs @ 16"o.c. 1.0
Misc. 1.0
Other
Total Load 7
Description : ROOF HEADERS
SIMPLY STRONG
ENGINEERING
Page 2 of 12
05/27/16
'1'W9pcf8ea,rn o~~i.prf t RH-1 UNE lt_-.-.,,, _ ___,., ,_,...,,_~·-=--="",--,-=~=~=-~-=-,-,,.,,,,-}: ;'_
;.:_ __ ~~ ... :~~ .. :~~...:;. _ ",;-,; . -, -, ~ .~, :-.. :_·, . ~ ,--. ~----~~~~:~~-~~'"':~ .. : .. ~:~~' ~€~ICutations~per~NE>S'.201~,11B~~~012,,~ljl~~~Q1~,~ASCE·.7;.10
BEAM Size : 6x10, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species :
Fb-Tension
Fb-Compr
Applied Loads
Douglas Fir -Larch Wood Grade : No.2
875.0 psi Fe -Prll 600.0 psi Fv 170.0 psi Ebend-xx
875.0 psi Fe -Perp 625.0 psi Ft 425.0 psi Eminbend -xx
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr= 0.020 kif!, Trib= 24.0 ft
Design Summary
Max fb/Fb Ratio = 0.581; 1
fb : Actual : 634.01 psi at 3.000 ft in Span # 1
Fb : Allowable : 1,091.25 psi
Load Comb : +D+Lr+H
Max fv/FvRatio = 0.291 : 1
1,300.0 ksi
470.0ksi
fv : Actual : 61.90 psi at 5.220 ft in Span # 1
Fv: Allowable: 212.50 psi 6.0ft, 6x10
Load Comb : +D+Lr+H Max Deflections
Density 31.20 pcf
Max Reactions (k) Q J. J.r ~ ':tJ. !; !:I. Downward L+Lr+S 0.028 in Downward Total 0.056 in
Left Support 1.47 1.44 Upward L +Lr+S 0.000 in Upward Total 0.000 in
Right Support 1.47 1.44 Live Load Defl Ratio 2613 >240 Total Defl Ratio 1291 >180
r"Y~-~d~~ea~~pe~1igh ';. fRH-filNE]f"°" ' . . ' --,..---y~~ ' ' ' • ,, .. ". • " "":=™?:~:') l /.'" ~~,, • :·· <· • ;. / .. -~: • '.• · •• ~ ;. .. :. ,, • . ~ ·-~-~al?.u,l~~~':!_~-~-~.E!'.~,R12,;IBG~O~~;jGQ.C',20131:A~CE;,7:·~-~
BEAM Size : 5.25x11.25, Parallam PSL, · Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.0E
Fb -Tension 2900 psi Fe -Prll 2900 psi Fv 290 psi Ebend-xx 2000 ksi
Fb -Compr 2900 psi Fe -Perp 750 psi Ft 2025 psi Eminbend -xx 1016.535 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr= 0.020 kif!, 0.0 ft to 7.0 ft, Trib= 18.0 ft
Unif Load: D = 0.020, Lr= 0.020 kif!, 7.0 to 13.250 ft, Trib= 15.0 ft
Unif Load: D = 0.010, Lr= 0.010.klft, Trib= 5.0 ft
Design Summary
Max fb/Fb Ratio = 0.522; 1
fb : Actual : 1,868.92 psi at 6.404 ft in Span # 1
Fb : Allowable : 3,582.81 psi
Load Comb : +D+Lr+H
Max fv/FvRatio = 0.322 : 1 ~ fv : Actual : 116.83 psi at 0.000 ft in Span # 1
Fv : Allowable : 362.50 psi
Load Comb : +D+Lr+H Max Deflections
13.250 ft, 5.25x11.25
Density 45.05 pcf
Max Reactions (k) Q .!. J.r Q ':tJ. !; H Downward L+Lr+S 0.214 in Downward Total 0.439 in
Left Support 2.75 2.63 Upward L+Lr+S 0.000 in Upward Total 0.000 in
Right Support 2.55 2.43 Live Load Defl Ratio 742 >240 Total Deft Ratio 362 >180
IWo.acFB·e·am'Bes·ign:: tRH-3.(LfNE'm== = '' ™""-'="-Y~= .. mmra .... ......mr== .. ==rbJ l : · r ::· .\ .'-· ::' : : ~-' , ~· · -~~""':--~:; ·. .. •· · ,. -, ·. · . . ~· . . l ·: .. • .. : , , .r~a1cu1atr90~~-,per,t-i1q§,;2qn~ffi~~ ~~1J;E!I~f2'.'(53!~E'fl.J.i12~
BEAM Size : 6x8, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir -Larch Wood Grade : No.2
Fb-Tension
Fb-Compr
875.0 psi Fe -Prll 600.0 psi Fv 170.0 psi Ebend-xx 1,300.0 ksi
470.0 ksi
Density
875.0 psi Fe -Perp 625.0 psi Ft 425.0 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr= 0.020 kif!, Trib= 12.0 ft
Point: D = 1.10, Lr= 1.10 k@0.750 ft
Design Summary
Max fb/Fb Ratio =
fb: Actual:
0.384; 1
419.13 psi at
1,092.63 psi
+D+Lr+H
Fb : Allowable :
Load Comb:
Max fv/FvRatio =
fv: Actual:
Fv : Allowable :
Load Comb:
Max Reactions (k)
Left Support
Right Support
0.390: 1
82.98 psi at
212.50 psi
+D+Lr+H
Q .!.
1.30 0.67
.!.r
1.28 0.66
0.782 ft in Span# 1
0.000 ft in Span # 1
H
Max Deflections
Downward L +Lr+S
Upward L +Lr+S
Live Loa9 Def! Ratio
3.50ft, 6x8
0.007 in Downward Total
0.000 in Upward Total
5686 >240 Total Defl Ratio
31.20 pcf
0.015 in
0.000 in
2820 >180
~ SI.MP LY STRONG
~ ENGINEE.RING.
Page 3 of 12
05/27/16
'-W~gcJ~·a:e:~mQe$is:J'r'.V: ·! RH-4 LINE E) aaao:;;;i,-;,c~ ' ™-"""""··'"-""'--"'"""'""'"M'"""·=--·-!'. ·Jl I .~ : i .: · .. Y •. i , ; ; , :· ' -~~L~~,,, · ·-~.--:.:~~ ~c '. •Qat9~!alj~n~ ,iferINtH~-iq1'.2;~13G-iq,i2j~~c~~~;:-t~~:9~J
BEAM Size : 6x8, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir -Larch Wood Grade : No.2
875.0 psi Fe -Prll 600.0 psi Fv 170.0 psi Ebend-xx Fb -Tension
Fb-Compr 875.0 psi Fe -Perp 625.0 psi Ft 425.0 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Point: D = 1.0, Lr= 1.0 k@ 4.0 ft
Unif Load: D= 0.040->0.10, Lr= 0.040->0.10 k/ft, 0.0 to 6.0 ft
Design Summa,y
Max fb/Fb Ratio = 0.701-; 1
fb : Actual : 765.46 psi at 4.000 ft in Span # 1
Fb : Allowable : 1,091.80 psi
Load Comb : +D+Lr+H
Max fv/FvRatio = 0.293 : 1
fv: Actual: 62.34 psi at 5.380 ft in Span# 1 Fv: Allowable: 212.50 psi
Load Comb : +D+Lr+H Max Deflections
6.0 ft, 6x8
1,300.0 ksi
470.0ksi
Density 31.20 pcf
Max Reactions (k) Q !: !d: §. 'fY. !; !:!. Downward L+Lr+S 0.035 in Downward Total 0.071 in
Left Support 0.54 0.51 Upward L +Lr+S 0.000 in Upward Total 0.000 in
RightSupport 0.93 0.91 Live Load Defl Ratio 2065 >240 Total Defl Ratio 1017 >180
1w~~-<f-,a~artj. a~§l.Qi:f;:. RH-s (LINE G) ______ ·~-. . . . .,_ -~ . . :~:1 u~~-· ~ : ' :...:~2.J:..::...:.....:.:. ' ':, '. " -~:0 h ,,. ' " • •• \ ~ '' ' ~~ eaLc.w~t!s>.~~,Bl~~1-~(~~~2~21-C!!~Pil ·-· --... ~J
BEAM Size : 5.25x9.25, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Trus Joist Wood Grade : Parallam PSL 2.0E
Fb -Tension 2900 psi Fe -Prll 2900 psi Fv 290 psi Ebend-xx 2000 ksi
Fb -Compr 2900 psi Fe -Perp 750 psi Ft 2025 psi Eminbend -xx 1016.535 ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr= 0.020 k/ft, Trib= 6.50 ft
Design Summa,y
Max fb/Fb Ratio = 0.445; 1 D{0.130) Lr{0.130)
Density 45.05 pcf
fb : Actual : 1,593.44 psi at 8.500 ft in Span # 1 Fb : Allowable : 3,579.99 psi
Load Comb : +D+Lr+H J I t I MMM itE 4±Htfl(
ZS Max fv/FvRatio = 0.182: 1
fv: Actual: 65,99 psi at 16.263 ft in Span# 1 Fv : Allowable : 362.50 psi
17.0 ft, 5.25x9.25
Load Comb : +D+Lr+H Max Deflections
Max Reactions (k) Q !: !d: §. 'fY. !; !:!. Downward L+Lr+S 0.355 in Downward Total 0.751 in
Left Support 1.23 1.11 Upward L +Lr+S 0.000 in Upward Total 0.000 in
Right Support 1.23 1.11 Live Load Defl Ratio 575 >240 Total Defl Ratio 271 >180
BEAM Size:
Wood Species :
Fb-Tension
Fb-Compr
Applied Loads
6x8, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Douglas Fir -Larch Wood Grade : No.2
875.0 psi Fe -Prll 600.0 psi Fv 170.0 psi Ebend-xx
875.0 psi Fe -Perp 625.0 psi Ft 425.0 psi Eminbend -xx
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr= 0.020 k/ft, Trib= 10.0 ft
Point: D = 1.50, Lr= 1.80 k@ 0.50 ft
1,300.0 ksi
470.0ksi
Density 31.20 pcf
Design Summa,y
Max fb/Fb Ratio =
fb: Actual:
--------------------.. -··--············· -------
Fb : Allowable :
Load Comb:
Max fv/FvRatio =
fv: Actual: Fv : Allowable :
Load Comb:
Max Reactions (k)
Left Support
Right Support
0,325; 1 354.79 psi at
1,092.95 psi
+D+Lr+H
0.157: 1
33.42 psi at 212.50 psi
+D+Lr+H
Q
1.46
0.56
!: !d:
1.69 0.61
0.500 ft in Span # 1 1
1.883 ft in Span # 1
!:!.
Max Deflections
Downward L +Lr+S
Upward L +Lr+S
Live Load Defl Ratio
2.50ft, 6x8
0.003 in Downward Total
0.000 in Upward Total
9866 >240 Total Defl Ratio
0.006 in
0.000 in
5243 >180
SLMPLY .STRONG
ENGlNEERING
Page 4 of 12
05/27/16
.. ',,, •·. " "S ;~."<File,,::~:\Rrpjectsl4a16\11:~HUJtl:i\GiL¢\bo\Ylihg;ec6; ~
... ,~ENERC.A¼61;1t{E?,'1983~~~ttj;:~J:!iJdi~1~.~;5.1~;iygh§.'1!l.:~.~;t;-_;;
Description : ROOF BEAMS
f'Y'ifQ,~d:.8:'eam;De~i91J :{R~-1 (LINE n===~ . -= . .. .~~.~ ~ .. ~--~== ·=~~,.-... JJ 1 t ·· · · · · .. · · < '~-'• '. ' · · •· , ... , ·.· · ··. ·. , , €,' • , • ., , , ... , , · 1 Calculat1ons'.,pltNE>S,20!1\2',:;IBC' 20~€BC,2013;?ASCE·7.~:tf(i:J ~~ ... ,,,~ ........................ ..,. ........ ,..,.. ...... ~. · -~. : ,..-,,t,<'"f\_~~,:,.;;_:..........;;.,.;.:'°,t;i;::~;.;,:-.:':M:;.;l.i~~!~·~-···.,.:.:~-;,:;,,,J~~~~ .. ;,,,.-:,:···~.~,,.\:.1
BEAM Size : 6x10, Sawn, Fully Braced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir -Larch Wood Grade : No.1
Fb-Tension
Fb-Compr
1,350.0 psi Fe -Prll 925.0 psi Fv 170.0 psi Ebend-xx 1,600.0ksi
580.0ksi
Density
1,350.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr= 0.020 k/ft, Trib= 12.0 ft
Design Summary
Max fb/Fb Ratio = 0.404 · 1
fb : Actual : 682.05 psf at 4.375 ft in Span # 1
Fb : Allowable : 1,687.50 psi
Load Comb : +D+lr+H
Max fv/FvRatio = 0.238 : 1
fv : Actual : 50.60 psi at 0.000 ft in Span # 1
Fv: Allowable: 212.50 psi
Load Comb : +D+Lr+H
Max Reactions (k) Q !. !.r
Left Support 1.10 1.05 Right Support 1.10 1.05
.t!
Max Deflections
Downward L +Lr+S
Upward L +Lr+S
Live Load Def! Ratio
8.750 ft, 6x10
0.051 in Downward Total
0.000 in Upward Total
2074 >240 Total Def! Ratio
31.20 pcf
0.104 in
0.000 in
1013 >180
·Wc,p'(f;e:e,antQe.$itfr;tl RB-2 (LINE 1)
i{,, .. ,; 'J " ... -~,: ~-~-·.; -~~ .. ~"' -~ -,-:·· ,, • i::~; ;>: '.' ,, "'.; '' ,·~v,, ,~'·Ca[~J:il~!i<>ti~.P~r:NoSz~:~'IJ·;J~P~~~CQ~~«u?
BEAM Size : 8x10, Sawn, Fully Braced
Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir -Larch Wood Grade : No.1
Fb-Tension
Fb-Compr
1,350.0 psi Fe -Prll 925.0 psi Fv 170.0 psi Ebend-xx 1,600.0 ksi
580.0ksi
Density
1,350.0 psi Fe -Perp 625.0 psi Ft 675.0 psi Eminbend -xx
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr= 0.020 k/ft, Trib= 5.0 ft
Design Summary
Max fb/Fb Ratio =
fb: Actual:
Fb : Allowable :
Load Comb:
Max fv/FvRatio =
fv: Actual: Fv : Allowable :
Load Comb:
0.408; 1
688.21 psi at 7.750 ft in Span# 1 1,687.50 psi
+D+Lr+H
0.149: 1
31.64 psi at 14.725 ft in Span# 1 212.50 psi
+D+Lr+H
Q !. Max Reactions (k)
Left Support
Right Support
0.89
!.r
0.78
0.78 0.89
.t!
Max Deflections
Downward L +Lr+S
Upward L +Lr+S
Live Load Def! Ratio
15.50 ft, 8x1 o
0.152 in Downward Total
0.000 in Upward Total
1221 >240 Total Defl Ratio
31.20 pcf
----··-~
0.328 in
0.000 in
566 >180
Seismic Design
~-SIMPL.Y' STRONG
~ E .. NGINEgRJNG.
Page 5 of 12
05/27/16
Design Variables Base Shear Calculation (ASCE 7-10 Sec. 12.8 & Supplement 2)
Latitude= 33.16 c12.8-2) V = C5W Cs = Sos*I/R = 0.121
Longitude= -117.33
Site Class= D
Occupancy= II
Seis. Category = D
I= 1.0
R= 6.5
Ss= 1.120
S1 = 0.430
Fa= 1.052
Fv = 1.570
SMs = Ss*Fa = 1.178
SM1 = S1*Fv = 0.675
Sos = 2/3*SMs = 0.785
S01 = 2/3*SM1 = 0.450
All other structural systems
Ct= 0.02
X= 0.75
TL= 8
Ta= Ct*h/ = 0.121
T =Ta= 0.121
hn = 11.0
Cs= 0.121
k= 1
Cd= 4
/:J.a = hsx* 0.025
Table 1.5-1
Table 11.6-1 & 2
Tables 1-1 & 11.5·1
Table 12.2· 1
Section 11.4.1
Section 11.4.1
Table 11.4-1
Table 11.4-2
(11.4-1)
(11.4-2)
(11.4-3)
(11.4-4)
Table 12.8-2
Table 12.8-2
Table 12.8-2
Figure 22-15
(12;8·7)
Section 12.8.2
Section 12.8.2.1
Section 12.8.1.1
Section 12.8.3
Table 12.2-1
Table 12.12·1
(12.8-3) for TSTL: So1*I/(RT) Where: Cs max. = 2 (12.8-4) forT>TL: S01*TL*l/(RT)
(12.8-5) for S1<0.6:0.044S0sl;,:0.01 Where: Cs min. = (12.8-6) for s1;::o.6: 0.5S1 *I/R
Material
DL
(psf)
20
16
7
Area Len. Ht.
(tt:2) (ft) (ft)
4200
Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-10, Sec. 12.8.3 & 12.8.6)
Level Wx hx h/ Wxh/ fx fx (psf) % P i5xe allow.
Roof 114.1 11.0 11.0 1255 13.8 3.3 100% Yes 0.825
114.1 1255
Diaphragm Forces (ASCE 7-10, Sec. 12.10.1.1)
Level Wx IWx fx Ifx
Roof 114.1 114.1 13.8 13.8
114.1 13.8
14 3
fpx fpx (ASD)
17.9 12.6
Where:
Fmin. = 0.21SosWx
Fmax. = 0.41SosWx
= 0.573 Max.
= 0.035 Min.
w
(kips)
84.0
24.0
6.1
114.1
Where:
'5xe allow. = /:J.a *I/¼
(Section 12.8.6)
p : Redundancy Check
Required if story shear
is > 35% of base shear
(Section 12.3.4.2)
~ SIMP'LY STRONG Page 6 of 12
05/27/16 ,~ ~NGINEE:'RIN.G
Wind Design
Wind Pressures for MWFRS ASCE 7-10 -Envelope Procdedure Method 2
Design Variables
Occupancy=
Iwind =
Basic Wind Speed (mph) =
Exposure Category =
Topographic Kzt =
Width (ft)=
Length (ft) =
Roof Pitch
Eave Ht. (ft) =
Ridge Ht. (ft) =
Mean Roof Ht (ft) =
'A=
0=
'AKztI =
2a (ft)=
Min. Design Load (psf) ==
II
1.00
110
.. ,,,.g,' ~" ,, t .,,: 1, ! v·.
l'J[l:
30.4
25.2
1
22.6
1.0
19.0
16.0
Table 1.5-1
Tables 1.5-2
Figure 26.5-lA
Section 26.7.3
Section 26.8.2
Transverse
Longitudinal
Figure 28.6-1
Figure 28.6-1 Note 9
Section 28.4.4
Ps = 'AKztIPs3o (28.6-1) Note: (-) Horiz. Pressures shall be zero.
Horiz. Press.
(psf) A B C
Trc;msverse 25.3 -1.3 17.5
Longitudinal 19.2 -10.0 12.7
t111tt1tttlttttttttt
-------------------·1
~ Ridge
Eave height
height
i-----Widlh, W=
D E
0.2 -16.6
-5.9 -23.1
Vert. Press. Overhangs
F G H ECH GCH
-15.3 -11.7 -11.9 -25.8 -21.0
-13.1 -16.0 -10.1 -32.3 -25.3
Transverse
Zone Ps Area Force (k) Total (k)
A 25.3 380 9.6
B 0.0 198 0.0 36.5 C 17.5 1520 26.7
D 0.2 792 0.189514
Min. 16.0 2890 46.2 46.2
Wind pressures ere in psf
: *Because wind presence is less than zero (0), use O for design.
E
F
-16.6
-15.3
475 -7.9
475 -7.3 -60.0 I
Transverse Governing Design Force:
Transverse Tributary Area:
Transverse Governing Design Pressure:
ttttttttttl+tttftt+ft
Vertical
46.2 kips
2890 ft:2
16.0 psf
l
~Ridge Eave height
height
Wind pressures are in psf
Longitudinal Governing De$ign Force:
Longitudinal Tributary Area:
Longitudinal Governing Design Pressure:
20.2 kips
1260 ft2
16.0 psf
G -11.7 1900 -22.1
H -11.9 1900 -22.7
Min. -16.0 4750 -76.0 -76.0
Longitudinal
Zone Ps Area Force (k) Total (k)
A 19.2 455 8.7
B
C 12.7 805 10.2 19.0
D
Min. 16.0 1260 20.2 20.2
E -23.1 903 -20.8
F -13.1 903
G -16.0 1473
-11.8
-23.6 -71.1
H -10.1 1473 -14.9
Min. -16.0 4750 -76.0 -76.0
.~ SLMPL.Y STRONG
-~ ENG.fNE,ERiNG
Shearwa/1 Design r~: ~::;1u,MSels'~,.: (ft') = fld;s j _ L;ne: r . A l
Shear Line Len.Tot. (ft) = . 15. . p = 1.0
Wind Relative to Ridge= .. P~rpendicut~r I S05 = 0.785
Wind Lengths: Left Right Plate Ht. (ft) = 10
LH = Vert.Trib Height (ft)=:, :'.. •. .15.:Q'; LwanTot. (ft)= 9.5
Lw = Dist to Adj Gridline (ft) = ,~i:ct
,_....,.,. __ . --~~.,_,........·~~.,,
, : , . :Wood'Sh.e.&rwal!s ;=_
Seis. Wind
Strength Design Seis. Force: Fx = 3.3 psf
Maximum Wind Pressure: Px =
vxSeis.(ASO) = Area/2*Fx*P*0.7 = 2730
Vxwind = LH*Lw/2*Px*0.6 =
16.0 psf
lbs
3744 lbs
"DJ x (Above) = lbs
VxTotal = 2730 3744 lbs
Vxf L = 287 394 plf
Use Shearwall Type= @
with[}TP4]" clips @!T:~"'.""4&"o.c. SO% --~-....u-~ for entire length of grid line A
Length = · 9~~""'· ............. -,~·--"'t-..-.,..,......,,_ __ ...,,,, .. _,.=••-.
Load Type = Seis. Wind
Shear Load (lbs) = 2730 3744 ;-,..,~,-,..,"1""'.:".o-:r•ro-_,,_,,--,,_..,....,-1"7"--,.=.-~-t-..,...,,,,..,.,""'."".,....,".,.1,.~._.,,-""" R:~~-~~:. ~~ : :· ·~ ·~1· ~l~i::{;<;.'. .
Resis. DLp01nt (lbs) = I· . , ,. · '' ·:
Page 7 of 12
05/27/16
DLPolnt Dist (ft) = :, r--~~~~-~--..--~"""+~~-+--~--i--~~..,....~~f-"~~.,.....~~r--~-r-~-"-J
MomentoT (lb-ft) = 27296
1MomentResist. (lb-ft) = 3538 f------,f------f----+---t-~~-+----+----+----+---+---+---f----1 Uplift (lbs)= 2640
UpliftAbove = ~-•;"":::; i_:~ ~-·-· -· ,p'~-..:-.... ,""...;_..;_.+---+-....;,;;;,,"'--',1--..:.;..;'-'.;.;;;....,;.1.c.."'.:.""""il'""""~.;;.:,;.1;.;,,.:,,s.:,.,;,.=·1
UpliftNet. = 2640 3679
Left Holdown = Per Plan
Right Holdown = Per Plan
R·,. ·11. . . ·--:-N . ·1 . c:··~1=]·. QO,,..: ... ·.1 ,; , ' , .-, • -S,·; Lme: .,'.. ',,. :I!.: .. -.. :
Seis. Area (fi:2) =j 4299. · •· 'JI;:, i . ··l' ,
Shear Line Len.Tot. (ft) = }· 4~ : ---~ p = 1.0
Wind Relative to Ridge = ~ ·Perpendlc;ular-;l Sos = 0.785
Seis. Wind
Strength Design Seis. Force: Fx = 3.3 psf
Maximum Wind Pressure: Px = 16.0 psf
VxSeis.(ASDJ = Area/2*Fx*P*0.7 = 4941 lbs
Wind Lengths: Left Right Plate Ht. (ft) = 10 Vxwind = LH*Lw/2*Px *0.6 = 6624 lbs
LH = Vert.Trib Height (ft) =' -15;0·-·· ,: • l:5.0 · ; Lwan Tot. (ft) = 26
Lw = Dist to Adj Gridline (ft) = i . .. , . , ..
"DJ x (Above) = lbs
Vxrotal = 4941 6624 lbs
Vx/L = 190 255 plf
Use Shearwall Type= @
~'""t'~--": r,-:v;.~'"'<"'R1 witht,,l:.T~~-j clips@t_;:.~J"o.c. 82%
for entire length of grid line E
Length = _. _____ "11 __ . _·-·1_· :.,_;._ .. '-1=;:llS::..·-· --i-:---c.,;.;-~.;.;,.. ..... ..;.;;.;.,"'-,:...:.~c.J.1,,,,;;.,.;'""'"'··~,-~J.c.
Load Type = Seis. Wind Seis. Wind
Shear Load (lbs) = 2090 2802 2850 3822 r----,-----·----~, Wall DLDist. (psf) = · 1 . ;: ., . 7.
0
Resis. DL01st. (plf) = · ~ · ..
Resis. DLp0Jnt-Clbs) = · · '"' ·~
DLPolnt Dist (ft) = · · 1---------t--~------~--+----~--"t--'~---r'-~~-P-~---tc,-,..~-----1
MomentaT (lb-ft) = 20903 28025 28505 38215
1MomentResist. (lb-ft) = 2075 2541 3859 4725
Uplift (lbs)= --~?93 2427 1700 2310 ~--. -=--,~--
UpliftAbove = -~., ,
UpliftNet. = 1793 2427 1700 2310
Left Holdown = Per Plan Per Plan
Right Holdown = Per Plan Per Plan
'Resisting Moment DL is reduced by 0.6·0.14*S05 for S_eis.(12.14.3.1.3) & 0.6 for Wind (2.4.1)
~-SIM.PL.Y STRONG ~ . !c:NGiNE'ERIN<i
Shearwa/1 Design G;~PQ!:. :~::2;·j~ '.~~o -1j LinelGif ;4:1
Shear Line Len.Tot. (ft) = ,'. ;2~ : p = 1.0
Wind Relative to Ridge= . Per,pendlcijiiijl Sos= 0.785
Wind Lengths: Left -~~-ht Plate Ht. (ft) = 10
LH = Vert.Trib Height(ft) = : jS;() .. LwanTot. (ft) = 4
Lw = Dist to Adj Gridline (ft) = . 47.b'
Strongwall Capacity = 1525 1950 1525 1950
SW24xl0 SW24x10
Strength Design Seis. Force: Fx =
Maximum Wind Pressure: Px =
VxSeis.(ASD) = Area/2*Fx*P*0.7 =
Vxwlnd = LH*Lw/2*Px*0.6 =
r>lx (Above) =
VxTotal =
Seis.
3.3
1379
1379
Wind
16.0
3384
3384
psf
psf
lbs
lbs
lbs
lbs
Vx/L = 345 846 plf
Use ~!'!'all Type= ~ <::)
with~'i;:t.Ri] clips @Lt:t5?~"o.c. 48%
for entire length of grid line G,1-4
Page 8 of 12
05/27/16
·.: :Wood"$tfQngwafls :d: ' "."~-) ,; h~;ftbncr'ei:e ;,:.r, ,-,,..,_..,_ ,--~---,. ,""2'7',.-:-._~i,7';:,<:::/c/$:t,,-,._:~,,.,_.,---,,,~-,.-=2--,--·· .. ~,.""': :--,+ .. ----'-~~-,-,-,-,--,-,-..,..,,.,,..,-,+,,,-,-,,.,,-,--,-i-='"""""+.F:-.,-,-,-,ry.,.-;-;-,,d
Load Type = Sei~. · Wind·· s~~: Wind
Shear Load (lbs) = 690 1692 690 1692 0 R:~~-~~:. %~6: ~· ~: .·, '.;~t:tt~~~ifT?:t~ :: F 7~
Resis. DLp0Jnt (lbs)= ·
DLPolnt Dist (ft) = ' ., f---""""--,~'"'--'-'--'1--'---r~--+---+-"'---'---+-..:...........::....;::..-'-'--~+"'-"-'-'--'2:C4-''-'-"."--'.4"'--'-J"-""~=~
MomentoT (lb-ft) = 6896
1MomentResist. (lb-ft) = 157 192 157 192
Uplift (lbs) = 4493 11152 4493 11152
UpliftAbove = ~'""".;tf;~'.T; ,: ··-1-· _,· • .... · ..,' ... ' ,_. -·-· "";""·-,·,':, ·:,::::·.:::::·:::::=~-::.~:.:.:,:'',~:-:,.~·-~:.:l,:~""-:~~1
1
:.-.. ::'"'~"'11
Upli~et. = 4493 11152 4493 11152
Left Holdown = Per Plan Per Plan
Right Holdown = Per Plan Per Plan
CT:"t'. '.R.d.o:~i:.~r~a-(ft2)·;f~~~~.. Line:l.,fJ):4~;JSf Strength Design Seis. Force: Fx = s;~· Wi
nd
psf
Shear Line Len.Tot. (ft) =I . 16 ° p = 1.0 Maximum Wind Pressure: Px = 16.0 psf
Wind Relative to Ridge = ! ,' ~Ri;rpeciclicµI~ Sos = 0.785 VxSeis.(ASD) = Area/2*Fx *p*0.7 = 919 lbs
Wind Lengths: Left Right Plate Ht. (ft)= 10 Vxwind = LH*Lw/2*Px*0.6 = 2880 lbs
LH = Vert.Trib Height (ft) =r-."'~rc-·: LwanTot. (ft)= 7 r>lx (Above)= lbs
Lw = Dist to Adj Gridline (ft) = i i4Q;Q Vx Total = 919 2880 lbs
Shear Above: Line= j': · . '. :, · ' .. ·. ·· · ' _':.' ' : ' ··< : :_ .,; ·: ~·,-; 3.5:1 = (h/2L)* Vx/L = 188 411 plf -'<it.ti/,~.............,.~--~----..-...... ~
VxAbove (Seis/Wind) = f:;"l
0
/o-r,ib. of Load ===================================: Use Shearwall Type= 0 VxAbv.Tnb. (Seis/Wind) = withf1&.!f_!:] clips @l_:J~"o.c. 54%
for entire length of grid line G,4-6 --~--------·, ..z:·:· ,, "· Wood:$Mi3r.w~lls =, W1 W2
Length= · 3.5 ·'· ,., '· 3:5 · , :.:..~~~~-:'..,;~ ..... --.~-... , ..... "·"b·¼""'~'"··¼4 .. ~r,-.....:.. ... ,...-~ ..... ,
Load Type = Seis. Wind Seis. Wind
Shear Load (lbs)= 460 1440 460 1440 0 o
Wall DLo;st. (psf) = .' :-,-16·'.· .: ~-~.""'.'""."'~'""'''~ ''}. ,.-~-~ ..
Resis. DLo;st. (plf) =
Resis. DLp0;nt (lbs) =
DLPaint Dist (ft) = 1---~,-----1-~---r-~--+---r-~-'t-~--i-~~-+---'--'-"----r-'~'-'-'+-'---"'-~,-f="'-"~
MomentoT (lb-ft) = 4597 14400 4597 14400
1MomentReslst. (lb-ft) = 480 588 480 588
Uplift (lbs) = 1372 4604 1372 4604 • -
UpliftAbove = ~ ;--.-. ~-: ~~ ; S .:,.
Upliltr;et. = 1372 4604 1372 4604
Left Holdown = Per Plan Per Plan
Right Holdown = Per Plan Per Plan
1Resisting Moment DL is reduced by.0.6·0.14*505 for Seis.(12.14.3.1.3) &·0.6 for Wind (2.4.1)
MPLY STRONG
E·NGiNl=ERl!~-i'G
Shearwa/1 Design
p ;,:.,;.J ·1cr'l'Rqof:·: , · E W~ Line·r · 1: · .. ]
Seis. Area (i't2) = ;foo5; l; •: .'· G
Shear Line Len.Tot. (ft) = . , .93 . t.....__.. p = 1.0
Wind Relative to Ridge= ·;Pi;ir~llel' · 1 Sos= 0.785
Strength Design Seis. Force: Fx =
Maximum Wind Pressure: Px =
Vx5e1s.(ASD) = Area/2*Fx*p*O.7 =
Wind Lengths: Left Right Plate Ht. (ft) = 10 Vxwind = LH*Lw/2*Px *0.6 =
LH = Vert.Trib Height (ft) =r-r:-:~~ LwanTot. (ft)= 20 "£1/x (Above)=
L,, = Dist to Adj Gridline (ft) = I . ,. . ' 4~to \ VxTotal =
Shear Above: Line = f,.;;,,...;;;.. __ -"-....,..."'--.;,.;.....;....;"""'"'"""""--1.----""-'-'-"'"""""I Vx/L=
VxAbove (Seis/Wind) = ,,,,__""""'....,,.....,,...,...__,, _______ ,,......,.,.......,,.1
Use Shearwall Type=
Seis. Wind
3.3
16.0
3563
3456
3563 3456
178, 173
@ 0;DT,ib. of Load = ....,.......,......: ..... """-'=•··....;,'-·~--....,;.-...., _ _;._,'--"',.....:,...;;.1
vxAbv.Trib. (Seis/Wind) = withL~~ clips @f:~'·.~:1sl"o.c.
for entire length of grid line 1
Length= ; f ?.20": ·s:,·1,..· ...... ...:....,_,i.;,..."""'"1
Load Type = Seis. Wind
psf
psf
lbs
lbs
lbs
lbs
plf
23%
Page 9 of 12
05/27/16
Shear Load (lbs) =1""'r3.;;;.56"i-'3~:-z3;;.,.4~5,.6:;:l->:....;;.'"l'"""~,...;;...-+-;;.....""'."'",_....;,:---i.,.,-.,;;-.~--:;;......,,1,r.....,;;~,...,,""=~"T,'1i,.,..ry;;; ___ ,_""",;;~1 Wall DL01st. (psf) = ~,. ' ' : 16 ',){, :~ :e:~:~-i~::: ~I:~ : :;,T :290\::{-':,, '
DLpoJnt Dist (ft) = l-"-'"""--'-,,_..c.'-"-"-+-"--'-'---+-""--+.-"-'--'--;...,:r,-'-,..;,.+"'-"'--'--+'"'--"---+----'"'--~--"--"-i!C-:.,.:_:__~-'-"-'~'-i
MomentoT (lb-ft) = 35628 34560
1MomentResist. (lb-ft) = 35282 43200 l-------+----+----+---+---l------+-----1----l---+------l------+----1
Upli~ (lbs) = -. _1_8 _. ~4!,3 __ --+·---,-•l&---,~.i~~.,...,,..,t,,,..,=•-+,,=,.,.,,..1,,,..,,, .. ""'·"'~.-1""'"'"""'=,~-'""l-~...,,,.,.1
UphftAbove = ~.1--'·-·-'·.,_, ...... f • ..._.:..· .:..:..;i..;..._.;;..:;;.1:.......;~=l·"--'~=l-•""-'....,-"'l~,;..;.,;,=.:...1=~='-'""'·l·"""':.;,;..;.;;., .• 1,:......~.::1~;,,,;:;...s::...1
Upliftr.et. = 18 N/A
Left Holdown = Per Plan
Right Holdown = Per Plan
Seis. Wind ~--~ ......... --' )fa6d·. Seis. Area (ft') = -' ,·~ """' ' Strengt ---'
. 41' j .~~..,,
Shear Line Len.Tot. (ft) = .. ' p= 1.0 Maxi
h Design Seis. Force: Fx = 3.3 psf
mum Wind Pressure: Px = 16.0 psf
Wind Relative to Ridge = ·. · : ,:Ri!r&l!et , 7 Sos= 0.785 ASDJ = Area/2*Fx*P*O.7 = 4827 lbs Vxseis.(
Wind Lengths: Left Right Plate Ht. (ft) = 10 Vxwind = LH*Lw/2*Px *0.6 = 3888 lbs
LH = Vert.Trib Height (ft) = ·i§;Q ·I ,.39:o .. Lwau Tot. (ft) == 24 "£1/x (Above) = lbs
L,, = Dist to Adj Gridline (ft) = t ·~;d J 'i~~p; . VxTotal = 4827 3888 lbs
Shear Above: Line= I -~ -' ,, ,y, ,. ~-' ,-S-,,, ' ... \'~~q, .,, '. ·. ,,;,t,' i'.~-~ ' VxAbove (Seis/Wind) = ------
%Trib. of Load = [, '· ,' ., . ,,, ·.,;,/
.. . .
Vx/L = 201 162 plf
Use Shearwall Type= @
vxAbv.Trib. (Seis/Wind) = r'.""'O"l"W?l IT"."".",""f"'gi 11 withlf.£!f1..J clips @r <, :~ .• J o.c. 70%
for entire length of grid line 3
Wood Snea'r;walls ~ W1 W2
Length= · 24. ·., a, '• • ·• '.;..· ·..1.·''--' · . .;...;..4-':.:o.· '.·;;...• ..;...;.;..,..i.,;._,_~I·""""'···-'·
Load Type = Seis. vJiiici"' ~--
Shear Load (lbs)= 4827 3888 .i-,......;:o __ -..;;.o_i-.;;.o __ .....,.,-1
Wall DLo;st. (psf) = 7' · · · · :, •
Resis. DL01st. (plf) = · ·. 30o'.
Resis. DLp0Jnt (lbs) = ·
,,: ''?', DLPolnt Dist (ft) = . · ' ,·: ,. ~ 1--~----r-'----+'-'--__._:--,-'-'--""'+"""'--'"--'r----"--f---',."-T-~~'-f-""'--'~..-'---"--'-'-i-'-~---"~-'l
MomentoT (lb-ft) = 48270 38880
1MomentResist. (lb-ft) = 52218, 63936 l-------+----+----+---+---1------+---+---l---+----,l------+---I Uplift (lbs)= -168 -1066
UpliftAbove = ' ,, .. · ·
Upliftr.et. = N/A N/A
Left Holdown =
Right Holdown =
'Resisting Moment DL is reduced by 0.6·0.14*$05 for Seis.(12.14.3,1.3) & 0.6 for Wind (2,4.1)
IMPLY STRONG Page 10 of 12
05/27/16
~~!J~~~~(~!!Jl!" -~~-~~;Vlt·; Line=[·· ·_· -~·4·', _:··::1
Se1s. Area (tt2) = · 650 _ . " : . , , , _
Shear Line Len.Tot. (ft) = ' i2 ,; p = 1.0
... " -·-
Strength Design Seis. Force: fx =
Maximum Wind Pressure: Px =
VxSeis.(ASDJ = Area/2*Fx*P*0.7 =
Vxw1nd = LH*Lw/2*Px*0.6 =
'Blx (Above) =
Seis.
3.3
Wind
psf
16.0 psf
lbs
1152 lbs
lbs
en C: ·2
~ Q)
c3
Wind Relative to Ridge= · ; Par~llel -S05 = 0.785 747
Wind Lengths: Left Right Plate l:lt. (ft) = 10
LH = Vert.Trib Height (ft) =h-·,:,-:-.n~ LwanTot. (ft)= 12
L., = Dist to Adj Gridline (ft) = · c ; · • 'f f6~f: VXTotal = 747 1152 lbs
Shear Above: Line = {: ~",, '·_ ., 1'. · · ·{ • ,:· . · -~:__:~~~~·.:._·.,;-' __ V,JL = 62 96 plf
Use Shearwall Type= @
with t]i/.-ji'p4] clips @I;.-·> !.,'is1 "o.c.
VxAoove (Seis/Wind) = ,..,,., ___ ..,.,._,... __________ .......,,......-J
0/oi-rib. of Load = ·. . ... i ' " -----------vxAbv.Trib. (Seis/Wind) = ' ..... ,..~ f.::,..,,..,:,.., .... ~ 31%
for entire length of grid line 4
. . ~;~J\earw~Tr;;;;·_-,_ ---:-::,--.-.,......--t-----,---W_2-:----+--:-...,......W_3 _"7'-n-!7,--,~-,--,-W.,.4,_.,.,,,.--:,--;ct,-:-.,-,.--=-,-W.,,.,s-,,,-.,...--+--.-,,,=W,..,.,,-s ..,...,..,~
Length =1_.....,_"'.wf',__......:,.1
Load Type = i--=="--''---'-'-"-'-"--+------'-----+---'----+-----'-----f----'---+----'------1 Shear Load (lbs) = 1 _ ___,__..,.....
Wall DLo1st. (psf) = ;_
Resis. DL01st. (plf) =
Resis. DLPoint (lbs)=_.,::·-
DLPoint Dist (ft) :;:: l---'----.-~-~-'--'-"'-',-~~--+~~--~-+-~~...,...~~+-~-,--'-~~+---~~,-'--'~---1
MomentaT (lb-ft) = 7470 11520
1MomentResist. (lb-ft) = 9i73 112_32 f----1-----'----1---+----+---+---+----+----f---+---+---+-------I
Uplift (lbs) =-·1_4_8-+-~25_+-.,.....-i • ...,....~..,-.--.--i
Upli~ve = ,_··-_· --1,-· _,<: .... ,:,'-• ··..:.-'-4' _-. --~,-~ ....... +---·1;.,-;...,_;:....{"'""'.;;;;:;:'--'-11;;....,,;;.:.;;"'-'1"""'-'''""'""'+""'-~;.,w..,,._,,l,,""'--'~·-'-"""'-f--..;.•-.... I
Upli~et. =
Left Holdown =
Right Holdown =
~/A 25
Per Plan
Per Plan
Line:fi
I 1
p = 1.0
Wind Relative to Ridge = I ' -~ . -P,~t?tter:-·; Sos= 0.785
Wind Lengths: Left Right Plate Ht. (ft) = 10
LH = Vert.Trib Height (ft) = 'J?,0-I.:· '"'C' LwallTot. (ft) = 11 ' ,,
L., = Dist _to Adj Gridline (ft) = ; 4~!QJ '
Shear Above: Line= c. '"_!.'',· ,. :..,,._,';-' ,-.,;..''~ -~-·: '• . ,
VxAbove (Seis/Wind) = ----
0/oi-rib. of Load = ~ \ \ 1 ' , .•. "i' :,,, -,.
vxAbv.Trib. (Seis/Wind) =
-
'
Strength Design Seis. Force: fx =
Maximum Wind Pressure: Px =
Seis.
3.3
Vx5e;s.c
V
ASDJ = Area/2*Fx*P*0.7 = 2299
xWind = LH*Lw/2*Px *0.6 =
'Blx (Above) =
Wind
psf
16.0 psf
lbs
3456 lbs
lbs
VxTotal = 2299 3456 lbs
:,; ' '· ' , V,JL = 209 314 plf
-
.. ,i ·", f. ',~ Use Shearwall Type= @
with~] clips @~"o.c. 52%
for entire length of grid line 6
....-_,,........,,'f":'"".;'-"'c: ,, \ ' • ,,--
, ; ,-,;,,~ ~~q;Stj'~~fWalls :d W1 W2 W3
Length = ~, ... J~. ___ _;,_,_ ~-~~;:_:__: ~---...;.:..~·--... ~.;; __ ·: .... ::.""·· -4-,.._;-.c.-,--'-"--'-i----~.-,;...=--=i
Load Type = Seis. Wind
Shear Load (lbs) = 2299 3456 0 0 0
Wall DLDist. (psf) = ., _ }6'
Resis. DL0;5t. (plf) = , · 41Q :
Resis. DLPoint (lbs) =
1 DLPoint Dist (ft) = : i--~--,,-----1-----,-~--1-~~--,--'---t--~-,---~--t--~~---+-~~r'-~--'--I
MomentaT (lb-ft) = 22986 34560
1MomentResist. (lb-ft) = 17788 21780 t------1-----+---+----+----+----+----+----+-----+---+---+-----l Uplift (lbs) = 495 1217
UpliftAbove = 1---....;.-1---+---+-----+-·...;.;--1--...... ----'-l~'"'-'-"•=.i1~-' ... '··-~l'-<'-'·"'''"-"I
Upli~et. = 495 1217
Left Holdown = Per Plan
Right Holdown = Per Plan
'Resisting Moment DL is reduced by 0.6-0.14*505 for Seis.(12.14.3.1.3) & 0.6 for Wind (2.4.1)
~ SlMPLY' STRO·NG
~ ENGINEERING
Shearwa/1 Design
[."":'Y~~ •... ,:Ro6f'-... ,,· .. 'E·W7 L" -~-~'..'. ~-:· l __:,.' '"• ,, .. :_~...::..:,,,.;.._:, . ,.; ·.· .. j me.i .... ,',7'; ·,.
Seis. Area (ff) = . 10Q0 1 L.:: · · . ,'.. , · . •
Shear Line Len.Tot. (ft) = : 1I L, __ . . p = 1.0
Wind Relative to Ridge= .·. ~ ,PqrnlJel; 7 Sos= 0.785
Wind Lengths: Left Right Plate Ht. (ft) = 10
Ltt = Vert.Trib Height (ft) = f~~~O ;\; -Lwa11 Tot. (ft) = 12
Lw = Dist to Adj Gridline (ft) = · ~Q,O .
Length= · ,,1,z·.t ·, ··• i. ... ,
Load Type = Seis. Wind
Shear Load (lbs) = 1149 2160 0 0
Wall DL01st. (psf) = ~1~· , .. · · .. ;.· ·· :;, . '.~:"I,
Resis. DL01st. (plf) = '80 · ·· · ' }',;.,
Resis. DLPoint (lbs) = . ,,
Seis. Wind
Strength Design Seis. Force: Fx = 3.3
Maximum Wind Pressure: Px = 16.0
VxSeis.(ASD) = Area/2*Fx*P*0.7 = 1149
VxWind = Ltt*Lw/2*Px*0.6 = 2160
'Blx (Above) =
VxTotal = 1149 2160
Vx/L= 96 180
Use Shearwall Type= @
withf('tP33j clips @r·:::~f'.4aj"o.c. ·-=--for entire length of grid line 7
psf
psf
lbs
lbs
lbs
lbs
plf
Page 11 of 12
05/27/16
31%
DLp01nt Dist (ft) = 1--' ---,---t---.---'--'--+-__:_-'r-'__:__:,;_+-.:....o:::::::....:.µ=.;:.--"-'f.:c::_:~~~=-=fd1:,;;_;~4--~c...wj
MomentoT (lb-ft) = 11493
1MomentResist. (lb-ft) = 8468 l--:-:-:c-+--:--:==--+---+----+-------,f----+---+---+----+-------,---+---l Uplift (lbs) =
UpliftAbove = • , ---f-_,..-t---"'-"'--i-"""'-"""""'f
Upli~et. = 263 977
Left Holdown = Per Plan
Right Holdown = Per Plan
SIMPLY STRONG
ENGINEERING.
Page 12 of 12
05/27/16
Perforated Shear Wall Analysis
Wood Framed Shear Walls with Openings (SEAOC Design Manual Vol. II)
Grid Line: f< -{.· ,~oof I: >] Gov. Force: ~--:c~~ 2800 lbs Vert. Shear Force Above Header
1 1098 1 S05 = 0.785493 Uniformly Distributed Resisting DL = '" 1QO plf
Wall Dimensions (ft) W1 W2 Header Strap Tension
-"'I~""""-:§)"\ a. J ' •
W.nd6y,;; ) . 3.5;. ; ; ! ' :: ·. . :6 · V (lb) =1,-(-22-0)-,1 I 1647 I ,-1 (-27-5)-,1
Hl = ~-· ;, ~;'
H2 = _:.
Shear (bove o1enin~
v (plf) =I (63) I 549 LJffi_J
H3 = ·,·'··£
Horiz. Force @ Openiµg.___,
V (lb) =I 1427 I LJmJ
12.75 ft .---..... Shear @ Opening .---.....
v (plf) =I 408 I I 422
Vert. Shear Force Below Sill
Max Shear= 878 plf @
Overturning Moment = 25200 lbs*ft
1 878 1 T (lb)=
Sill rrap Terion
V (lb) =I (1208) I 2635 I (1263) I
1Resist. Overturning Moment = 4877 lbs*ft
Resulting Uplift Force = 1594 lbs Holdown Per Plan
Shear Below Sill .------,
V (plf) =I (345) I I 878 I I (389) I
Header Strap Tension = 1647 lbs DblCS16
Sill Strap Tension = 2635 lbs DblCS16
48% .---..... Vert. Shear Force .---.....
77% T (lb) =I 1976 j j -1976 I
'Resisting Moment DL is reduced by 0.6-0.14*505 for Seis.(12.14.3.1.3) & 0.6 for Wind (2.4.1)
Foundation Design
Distributed Loads
Grid line: [TI q= [.i1:00j psf (Note: All loads are psf and lengths are ft)
w= Ext. Wall*Ht. + Int. Wall*Ht. + R1*Span/2 + R2*Span/2 + F1*Span/2 + F2*Span/2= Total Load
w= 16 *I 1Q.=O-i+ 7 *C:=J+ 40 *!,so:qj/2 + *r~ .. ·. /2+ . * c:rw12+ --, *j,;:;":] /2= 1160 plf
Gov. Load: D+Lr = 1160 plf Use:· $2 "Wide x l'·ctzJ "Deep w / ( f,?~·"D ._Z#4~] Bars T&B
Loaded: [~·§
Concentrated Loads
Pad Ftg: H~1n cJ10if01psf r,~. · · 'i ·.1 ·1 ,~"'-!"""'7-·--"'1 D( Ll.fill.Q )+Lr{ ·. 2600:J )+L( L:..'...~) + W(! = ~-3) + E( t r , .; -h:iJ) =
Gov. Load: D+Lr =
v'(144* 5400 / 1700 )= 21.4 "Min. Square Dimension
Use: I;. ~4] "Sqr. x[ ~2_J" Deep with (3) (!]] Bars Ea. Way
5,400
5400
# Total Load
# Factored Load
Loaded: [ tmt]
_I Job ; •. Truss
/ EI\JGINEERING AA01
Truss Type
GABLE
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional
~California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 0212:37:56 2016 Page 1
ID:ZKw9I?x7pMrCNB?W4AMGRDzHVMu-HzsoKOzi6_AA97rCXqCyPq1xxYubDud2x9hfURiAl5
15-8-5 23-3-0 30-9-11 46-2-8
7-6-11 7-6-11 15-4-13
5x6=
2x4 II 2x4 II
18 19 20 99
2x4 1198
2x4 11 97 17 .?':.-.!lf/lt"W,.:----_
2x4 1196 16
2x41195 15
5.50[12
2X4 JI 2x4 \\ 94 14
13'
~41192 1293
5>c6~ 2x4 ll 91 11
2x4 ll 89 9
2x411888
10
2x4 1167 7
2x4ll866
2x4 !185 5
2X4!184 4
3 •
12 11 10 69 ss fil 66 ss 6463 62 s1 60 ss 58 57 s/ ss 54 53 52 s1 so 49 48 47 46
3>:6=
2x4!1 2X4l!
45 44 43 42 41 40 39 38
2x4fl 2x41! 2x411 2x4II 2x4ff 2x41f 2X4!1 2x4li 3"5= 2x411 2x41l 8X10= 2x,1-u 2x4il2x41! 2x41l 2x4U Bx10= 2x4!/ 2x41! •H•H•H•a•n•tt•dMH
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 •
BCDL 10.0
LUMBER
TOP CHORD 2x4 OF No.2 G
BOT CHORD 2x4 OF No.2 G
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1,25
Rep Stress Iner YES
Code IBC2012/TPl2007
WEBS 2x4 OF No.2 G *Except•
W1: 2x4 OF Stud/STD G
2x4 II 2x4-11 5-5 WB=
CSI
TC 0.28
BC 0.24
WB 0.44
(Matrix)
DEFL in
Vert(LL) 0.00
Vert(TL} -0.Q1
Horz(TL} 0.02
Wind(LL} 0.00
BRACING
TOP CHORD
BOT CHORD
WEBS
JOINTS
46-6-0
18-8-9
(loc} Vdell Ud PLATES GRIP
36 n/r 180 MT20 220/195
37 n/r 120
48 n/a n/a
37 n/r 120 Weight: 427 lb FT=20%
Structural wood sheathing directly applied or 5-0·9 oc purlins.
Rigid ceiling directly applied or 5-4-12 oc bracing.
1 Row at midpt 54-77, 55-82
1 Brace at Jt(s}: 74, 75, 76, 79, BO, 81
48-0-0
46~-o I 0--8
ildl-.0,n.
4x5::;
OTHERS 2x4 OF Stud/STD G *Except•
ST20: 2x4 OF No.2 G MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS All bearings 46·6-0.
(lb) • Max Herz 2=261 (LC 25)
Max Uplift All uplift 100 lb or less at joint(s)·38, 39, 40, 41, 42, 43, 44, 45, 46, 50, 52, 53, 54, 72, 71, 70, 69, 68, 67, 66, 65, 64,
60, q7, 56, 55 except 2=,667(LC 27), 51 =·430(LC 28), 59=-430(LC 27), 36=·667(LC 28), 48=, 178(LC 28), 49=-187(LC 22),
62=-178(LC 27), 61=,186(LC 27)
Max Grav All reactions 250 lb or less atjoint(s) 48, 49, 53, 54, 62, 61, 56, 55 except 2=740(LC 26), 51=526(LC 25), 59=539(LC 24),
36=728(LC 25), 38=348(LC 106), 39=284(LC 105), 40=295(LC 104), 41=287(LC 103), 42=284(LC 102), 43=280(LC 101), 44=277(LC 100),
45=274(LC 99), 46=271 (LC 98), 50=263(LC 95), 52=255(\..C 93), 72=348(LC 74), 71=284(LC 75), 70=295(LC 76), 69=287(LC 77),
68=284(LC 78), 67=280(LC 79), 66=277(LC 80), 65=274(tC 81), 64=271(LC 82), 60=263(LC 85), 57=255(LC 87)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb} or less except when shown.
TOP CHORD 2-83=-1578/1565, 3-83=-1476/1460, 3-~ 1358/1331, 4-84=-1295/1245, 4-85=-1236/1217, 5-85=-1173/1169,
5-86=-1119/1098, 6-86=-1005/1050, &87 =-1000/980, 7-87=-887/933, 7-88=c882/862, 8-88=-769/814,
8-89=-764/7 44, 9-89=-651/697, 9-90=-647 /630, 10-90=·580/577, 10-91 =-528/543, 11-91 =-459/490,
11-92=-380/432, 12-92=-279/351, 12-93=·349/421, 13·93=·266/355, 13-94,,,-319/406, 14-94=-175/290,
14-95=-212/334, 15-95=-149/284, 16-96=,145/325, 16-97=-201/402, 17-97=·239/449, 17-98=-261/517,
18-98=-346/592, 18-19=-397/643, 19-20=·422/643, 20-99=·359/592, 21-99=·301/517, 21-100=,245/449,
22-100=-198/402, 22-101=·126/325, 23-102=-114/284, 24-102=-177/334, 24-103=·125/290, 25-103=-270/406,
25-104=·217/355, 26-104=,299/421, 26-105=,222/351, 27-105=-323/432, 27-106=-389/490, 28-106=-454/543,
28-107 =-493/577, 29· 107 =-557/630, 29-108=-547/625, 30-108=,660/715, 30-109=-672/710, 31-109=, 764/801,
31-110=·800/813, 32-110=-881/887, 32-111=·927/931, 33·111=-999/978, 33-112=· 1054/1050,
34-112=-1116/1097, 34-113=-1183/1126, 35-113=-1243/1211, 35-114=·1356/1340, 36-114=-1508/1445
BOT CHORD 2-72=-1378/1399, 71-72=-1177/1218, 70-71=-1067/1108, 69-70=-976/1018, 68-69=-876/917, !17-68=-776/817,
66-67=-675/716, 65-66=-575/616, 64-65=-475/516, 63-64=·374/415, 62-63=·324/365, 61-62=-274/315,
59-60=·211/252, 58-59=,426/522, 57-58=·336/432, 56-57=-326/422, 55-56=·225/322, 53-54=·225/322,
52-53=·326/422, 51-52=·426/522, 50-51=-166/252, 48-49=-229/315, 47-48=·280/365, 46-47=-330/415,
45-46=-430/516, 44-45=-530/616, 43-44=·631 /716, 42·43=-731/817, 41-42=-831/917, 40-41=·932/1018,
39-40=-1032/1108, 38-39=-1132/1218, 36-38=-1333/1399 •
WEBS 19·77=-970/934, 76-77=·89?/861, 75-76=·885/854, 51-75=·895/863, 51-74=·410/404, 73-74=-435/432,
25-73=-252/239, 59-80=-895/841, 80-81 =·885/832, 81-82=·892/839, 19-82=-970/908, 78-79=-426/432,
59-79=-402/404, 35-38=-304/55, 34-39=-263/42, 33-40=-267/36, 32-41=-261/36, 31-42=-257/;36,
30·43=-253/36, 29·44=·250/36, 24-74=·252/137, 3-72=-304/55, 4-71=-263/42, 5-70=-267/36, 6-69=-261/36,
7-68=·257/36, 8-67=-253/36, 9-66=-250/36, 14-79=-252/137
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-se90nd gust} Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=47ft; eave=6ft; Cat. 11; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; c:antilever left·and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face}, see Standard Industry Gable End Details as
applicable, or consult qualified building desig~er as per ANSI/TPl 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1 -4-0 oc.
6) This truss has been designed for a 10.0 psi bottom chord live·load nonconcurrent with any other live loads.
Continued on a e 2
Job : /Truss
ENGINEERING AA01 ,
California Trusframe LLC., Perris, CA. 92570
NOTES
/
Truss Type
GABLE l
~ty /Ply
1
I24190-Bowling Residence-rnichaelc
Job Reference (ootionall Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:37:57 2016 Page 2
ID:ZKw9I?x7pMrCNB?W4AMGRDzHVMu-lAQAYk_KtHI 1 nHQP5XjBx2a6hyEpyLtBApQC1 uzAl5e
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
8) A plate rating reduction of 20% has been applied for the green lumber members.
9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSl/f Pl 1.
10) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent with any other live loads.
11) This truss has been designed for a total drag load of 3500 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 46-6-0 for 75.3 pl!.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job ....,
ENGINEERING
Truss
AA02
Truss Type
Common
Qty
4
Ply 241 S0·Bowling Residence·michaelc
Job Reference o tional "'cahfornia TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:37:58 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu·DMzZl4?yebQtPR?beFFQUF6BIMY5hhnLPTAmZKzAl5
rH·g 3·11-10 9·8-5 17•2-7
11·6·0 3·11-10 5-8-10 7-6-2 6·0·9
5-11-0 13-2-14 19-5-0 22-6·4
5-11-0 7-3-14 6-2-2 3-1-4
Plate Offsets X 17:0+12 0·2·0
LOADING (psi) SPACING 2·0·0 CSI
29·3·9
6·0·9
5x10 JI
27-1-0 33-3-2
4-6-12 6-2-2
DEFL in (lac) I/dell
36·9·11
7-6·2
40-7·0
7-3-14
Ud PLATES
42·6·6
5·8·10
GRIP
48·0·0
46-2-8 46fi'-o I 3-8·2 o. ·-8
ildHlm.
46-6-0
5-11-0
TCLL 20.0 Plates Increase 1.25 TC 0.65 Vert(LL) -0.07 20·22 >999 360 MT20 220/195
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
BC 0.36 Vert(TL)
WB 0.78 Horz(TL)
(Matrix·M) Wind(LL)
-0.23 14-15 >999 240
0.02 12 n/a n/a
0.0414·15 >999 240 Weight: 261 lb FT=20%
TOP CHORD 2x4 DF No.1 &Bir G
BOT CHORD 2x4 DF No.2 G
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 5·9· 15 oc purlins.
Rigid ceiling directly applied or 6·0·0 oc bracing.
WEBS 2x4 DF No.1 &Btr G *Except*
W2,W1: 2x4 DF Stud/STD G
REACTIONS (lb/size) 12=809/0·5-8 (min. 0+8), 2=720/0·5·8 (min. 0·1-8), 18=2775/0·5·8 (min. 0-2-15)
Max Horz 2=261 (LC 9)
Max Uplift12=·123(LC 10), 2=·116(LC 10), 18=221(LC 10)
Max Grav12=837(LC 16), 2=720(LC 1), 18=2775([C 1)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2·30=1027/109, 3·30=·944/130, 3·31=·819/100, 4·31=691/124, 6-33=0/519, 7·33=0/674, 7·34=0/468,
8·34=0/336, 8·35=·380/161, 9-35=-381/134, 9·10=·472/113, 10·36=·993/140, 11-36=·1119/116,
11-37=-1241/145, 12·37=·1312/125
BOT CHORD 2-23=·34/1073, 22·23=64/610, 21·22=·389/179, 21-38=-389/179, 38-39=·389/179, 20·39=389/179,
19·20=·883/292, 18· 19=·883/292, 18·40=·699/275, 40·41 =·699/275, 17-41 =·699/275, 14· 15=0/693,
12·14=·4811-147
WEBS 7-17=·152/1164, 8·17=·948/220, 8·15=·58/758, 10·15=-636/175, 7·20=·160/1103, 6·20=·955/219,
6-22=·57/768, 4·22=-637/175, 4·23=0/463, 3-23=·354/112, 10· 14=0/460, 11-14=-350/111, 7-18=·2660/252
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
1 Row at midpt 8· 17, 6·20
2 Rows at 1/3 pis 7·18
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
2) Wind: ASCE 7· 1 O; Vult=110mph (3·second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=47ft; eave=6ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C·C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C·C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other.live loads.
4) * This truss has been designed for a live load of 20.0psf·on the·bottom chord in all areas where a rectangle 3·6·0 tall by 2·0·0 wide will fit between the bottom chord
and any other members, with BCDL = 10.0psf.
5) A plate rating reduction of 20% has been applied for the green.lumber members.
6) This truss is designed in accordance with the 2012 International B_uilding Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) "Semi·rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE($) Standard
~-
.1 _ENGINEERING
Truss
AA03
Truss Type
Common
Qty
11
Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 02 12:37:59 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-iYXxzQOaPvYkObanCymfOTflWmmoQFfUd7vJ5mzAl5
r1·6·s 3-11-10 9-8-5 17-2-7 23-3-0
1-6-0 3-11-10 5-8-10 7-6-2 6-0-9
4x6=
13-2-14 19-5-0
7-3-14 6-2-2
19:0·0·4 0-2-0
LOADING {psi) SPACING 2-0-0 CSI
29-3-9
6-0-9
S>ii II
27-1-0 33-3-2
7-7-15 6-2-2
DEFL in (lac) I/dell
36-9-11
7-6-2
40-7-0
7-3-14
Ud PLATES
42-6-6
5-8-10
GRIP
48-0-0
46-2-8 46~-o I
3-8-2 0--8
ibl>..O·n.
46-6-0
5-11-0
TCLL 20.0 Plates Increase 1.25 TC 0.90 Vert(LL) -0.2917-19 >999 360 MT20 220/195
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
BC 0.84
WB 0.36
(Matrix-M)
Vert(TL)
Horz(TL:)
Wind(LL)
-0.96 17-19 >584 240
0.31 12 n/a n/a
0.2117-19 >999 240 Weight: 247 lb FT=20%
TOP CHORD 2x4 OF No.1 &Bir G
BOT CHORD 2x4 DF No.2 G
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 1-7-8 cc purlins.
Rigid ceiling directly applied or 1 O·O·O oc bracing.
WEBS 2x4 DF No.1&Btr G *Except*
W2,W1: 2x4 DF Stud/STD G
REACTIONS (lb/size) 12=2152/0·5·8 (min. 0·2-5), 2=2152/0-5·8 (min. 0-2-5)
Max Herz 2~261 (LC 8)
Max Uplift12=·230(LC 10), 2=·230(LC 10)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
1 Rowatmidpt 8-17,6-19
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
TOP CHORD 2-29~4221/361, 3-29=·4181/382, 3-30=-4057/356, 3.0-31~3946/376, 4-31=-3932/380, 4-5=·3551/365, 5-32=-3465/385, 6-32=-3459/413,
6-33=-2959/405, 7-33=-2873/443, 7-34=-2874/443, 8-34=-2960/405, 8-35=3460/413, 9-35=-3466/385, 9-10=-3552/365, 10-36=-3935/380,
36-37=-3949/376, 11-37=-4061/356, 11-38=-4185/382, 12-38~225/361
BOT CHORD 2-22=·260/3954, 21-22=-199/3662, 20-21 =-64/2969, 20·39=·64/2969, 39-45~64/2969, 40°45=·64/2969, 19-40=-64/2969, 19-41 =0/2312,
18-41=0/2312, 18-42=0/2312, 17-42=0/2312, 17-43=·64/2821, 43-46=·64/2821, 44-46=-64/2821, 16·44=·64/2821, 15-16=·64/2821,
14-15=-199/3468, 12-14=-260/3762
WEBS 7-17=-137/1223, 8-17~911/221, 8-15=-60/707, 10-15=-595/171, 7-19=137/1222, 6'19=-911/221, 6-2k60/707, 4-21~595/171, 4-22=0/384,
3-22=289/103, 10-14=0/384, 11-14=-289/103
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 o; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=4011; L=47ft; eave=6ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 10.0psf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE{S) Standard
Job
ENGINEERING
Truss
AA04
Truss Type
Common
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o lional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 02 12:38:00 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-Ak5JAmOC9Cgbel9zmgHuZgCVm9959bKesnfsdCzAl5
r1·6-s 3-11-10 9-8-5 17-2-7 23-3-0
1-6-0 3-11-10 5-8-10 7-6-2 6-0-9
5X6=
4x5=
27-1-0
6-2-2 7-7-15
21:0-1-120-2-0
LOADING (psf) SPACING 2-0-0 CSI DEFL
29-3-9 36-9-11
6-0-9 7-6-2
33-3-2
6-2-2
in (lac) I/defl Ud
42-6-6
5-8-10
40-7-0
7-3-14
PLATES GRIP
48-0-0
46-2-8 46g'-o I
3-8-2 0--8
;66-.0m.
46-6-0
5-11-0
TCLL 20.0 Plates Increase 1.25 TC 0.81 Vert(LL) -0.11517-19 >999 360 MT20 220/195
TCDL 14.0
BCLL 0.0 •
BCDL 10.0
LUMBER
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/f Pl2007
BC 0.65
WB 0.78
(Matrix-M)
Vert(TL)
Horz(TL)
Wind(LL)
-0.5214-15 >843 240
0.13 12 n/a n/a
0.1514-15 >999 240 Weight: 252 lb FT=20%
TOP CHORD 2x4 DF No.1 &Bir G
BOT CHORD 2x4 DF No.2 G
WEBS 2x4 DF No: 1 &Bir G *Except•
W2,W1 ,W4: 2x4 DF Stud/STD G
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 2-2-1 oc purlins.
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS All bearings 10-5-8 except 0t=length) 12=0-5-8.
(lb) -Max Horz 2=-261 (LC 24)
1 Row at midpt 8-17, 7-19, 6-19, 6-21, 4-23
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
Max Uplift All uplift 100 lb or less at joint(s) 2 except 12=·421 (LC 28), 2=260(LC 25), 23=271 (LC 27), 22=· 143(LC 28)
Max Grav All reactions 250 lb or less atjoint(s) 2 except 12=1754(LC 16), 23=1698(LC 15), 22=975(LC 15)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-31=-535/977, 3-31 ~445/946, 3-32=-486/1113, 4-32=327/1190, 4-5;,-1043/523, 5-33=-952/460, 6-33=951/460, 6-34= 1595/454,
7-34=-1509/395, 7-35=-1945/391, 8-35=2031 /450, 8-36=·2539/523, 9-36~2539/524, 9-10=-2631/587, 10-37=-3076/603, 11-37=-3187/689,
11-38=·3328/733, 12-38=-3367/781
BOT CHORD 2-23=940/504, 22-23=541/696, 22-39=-570/726, 21-39=-571/726, 20-21=-421/1415, 20-40=-421/1415, 40-41=·421/1415, 19-41=-421/1415,
19-42=373/1401, 18-42=-373/1401, 18·43=-373/1401, 17-43=-373/1401, 17-44=-478/1936, 44-45=-478/1936, 16-45=-478/1936,
15-16=-478/1936, 14-15=-609/2641, 12-14=-653/2994
WEBS 7-17~141/1228, 8-17=-921/224, 8-15=63/719, 10-15~611/178, 6-19~3/317, 6-21=·1Q03/87, 4-24=0/560, 21-24=·3/1191, 4-23=-1810/344,
3-23=·395/122, 10-14=0/413, 11-14=-311 /120, 22-24=-859/164
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vull=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=4011; L=47ft; eave=6ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed; end vertical left a,nd right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DO_L=1.33 plate grip D0L=1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) This truss has been designed for a total drag load of 1000 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord
from 0-0-0 to 10-5-8 for 95.6 plf.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job "
ENGINEERING
Truss
AA05
Truss Type
COMMON
Qty
3
Ply 24190-Bowling Residence-michaelc
Job Reference a tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 MiTek lndustnes, Inc. Thu Jun 0212:38:01 2016 Page 1 ID:ZKw9I ?x7pMrCN8 ?W4AMGRDzHVMu-exfh051 qwWoSGukAKNo 76uke3ZV4u6An5ROQAfzAl5
38-0-0
7-2-7 13-3-0
7-2-7 6-0-9
19-3-9 26-9-11 32-6-6 36-2-8 36-6-0 I
6-0-9 7-6-2 5-8-10 3-8-2 0J3L8
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
4)dj:::::
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
5x6 =
4x6= 4)6= 4x6= 4)6::::: 4ldi=
""6=
17-1-0
7-7-15
15:0-2-4 0-2-0
CSI
TC 0.90
BC 0.66
WB 0.55
(Matrix-Ml
23-3-2
6-2-2
DEFL in (lac)
Vert(LL) -0.13 13-15
Vert(TL) -ci.53 12-13
Horz(TL) 0.14 10
Wind(LL) 0.1112-13
1-fuQ,.,~2
4x6= 4:£:::::
30-7-0 36-6-0
7-3-14 5-11-0
I/dell Ud PLATES GRIP
>999 360 MT20 220/195
>828 240
n/a n/a
>999 240 Weight: 224 lb FT=20%
TOP CHORD 2x4 DF No.2 G *Except•
T3: 2x4 DF No.1 &Btr G
BOT CHORD 2x4 DF No.2 G *Except*
B2: 2x6 DF No.2 G
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF No.1 &Btr G 'Except'
W6,W7,W1,W2: 2x4 DF Stud/STD G
REACTIONS (lb/size) 10=1755/0-5-8 (min. 0-1-14), 21=1786/0-3-8 (miri. 0-1-15)
Max Horz21~339(LC 8)
Max Uplift10=·150(LC 10), 21=-119(LC 10)
Max Grav10=1755(LC 1), 21=1796(LC 17)
FORCES (lb) -Max. Comp:/Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-25=-960/146, 3-25~875/156, 3-4=-807/179, 4-26=-1575/197, 5-26=-1489/235, 5-27~1943/256,
6-27=-2029/218, 6-28~2536/227, 7-28=-2536/200, 7-8=-2628/179, 8-29=-3065/203, 9-29~3176/179,
9-30=-3317/209, 10-30=-3357/188, 2-21~1775/146
BOT CHORD 20-21=-201/282, 20-31=0/1405, 31-32=0/1405, 19-32=0/1405, 18°19=0/1422, 18-33=0/1397, 17-33=0/1402,
17-34=0/1423, 16·34=0/1416, 15-16=0/1422, 15-35=0/1959, 35-36=0/1959, 14-36=0/1959, 13-14=0/1959,
12-13~3212637, 10-12~105/2990
WEBS 5-15=-76/1268, 6-15=-909/223, 6-13=·62/715, 8-13=·609/172, 4-19=0/412, 4-20=-1146/0, 8-12=0/412,
9-12=-313/111, 2-20:0/1380
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
1 Row at midpt 6-15, 5-19, 4-20, 2-21
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=37ft; eave=5ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) 120.0lb AC unit load placed on the bottom chord, 23-3-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 0.0psf.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb·live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the anaysis and design of this truss.
LOAD CASE(S) Standard
~ I ENGINEERING
Truss
AA06
Truss Type
COMMON
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:03 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-aJnRpn35S72AVCtYRoqbBJp?qNCnM2H4YltWEXzAI5
38-0-0
7-2-7 13-3-0 19-3-9
7-2-7 6-0-9 6-0-9
26-9-11 32-6-6 36-2-8 36-6-0 I
7-6-2 5-8-1 0 3-8-2 0J3L8
21 2X4 ,,
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
20
4lC6=
5x6=
5.50[12
3x5.::::,.
31 32 19 1833 17 341s 1s as 36 14 13
3x6= 4x6= 4)6;:;
8:0-1-15 0-2-4
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
4X6= 4l!S= 4xfi=
3>6=
17-1-0
7-7-15
CSI
TC d.88
BC 0.52
WB 0.45
(Matrix-M)
""'=
23-3-2
6-2-2
DEFL in (Ice) Vdefl
Vert(LL) -0.0713-15 >999
Vert(TL) -0.18 15-19 >999
Horz(TL} 0.06 12 n/a
Wincl(LL) 0.0415-19 >999
1-fuQ,.15~
4X6~
30-7-0 36-6-0
7-3-14 5-11-0
Ud PLATES GRIP
360 MT20 220/195
240
n/a
240 Weight: 224 lb FT=20%
TOP CHORD 2x4 OF No.2 G *Except*
T3: 2x4 OF No.1 &Btr G
BOT CHORD 2x4 OF No.2 G *Except*
82: 2x6 DF No.2 G
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 OF No.1 &Bir G *Except*
W6,W7,W1,W2: 2x4 OF Stud/STD G
REACTIONS All bearings 7-0-8 except Ot=length) 21 =0-3-8.
(lb) -Max Horz 21 =-343(LC 24}
Max Uplift All uplift 100 lb or less at joint(s) filXcept 10=-273(LC 28), 21 =-343(LC 27), 12=-259(LC 28)
Max Grav All reactions 250 lb or less atjoint(s) 10 except 10=337(LC 53), 21=1506(LC 17), 12=1873(LC 16)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-25~808/246, 3-25=-7221164, 3-4=-654/242, 4-26=-1261 /236, 5-26=-1176/341, 5-27 =-1321/336,
6-27=-1408/418, 6-28=-1287/431, 7-28=-1289/432, 7-8=-1379/519, 8-29=-176/519, 9-29=-369/573,
9-30=-331/508, 10-30=-440/558, 2-21=-1491/361
BOT CHORD 20-21~206/286, 20-31=-67/1161, 31-32=-67/1161, 19-32=-67/1161, 18-19=-87/1085, 18-33=-90/1063,
17-33~89/1069, 17-34~87/1086, 16-34=-88/1081 , 15-16=-87 /1085, 15-35=-189/1294, 35-36=-189/1294,
14-36=-189/1294, 13-14=-189/1294, 13-37 =-373/894, 12-37=-323/847, 10-12=-529/495
WEBS 5-15=0102/679, 6-15=-327/248, 6-13=-268/68, 8-13=0/523, 5-19=-162/371, 4-19=-147/350, 4-20~893/186,
8-12~1975/351, 9-12=-387/121, 2-20=-139/1109
NOTES
1 Row at midpt 6-15, 6-13, 4-19, 4-20, 8-12, 2-21
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 o; Vuli=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=4011; L=37ft; eave=5ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) 120.0lb AC unit load placed on the bottom chord, 23-3-0 from left encl, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psi bottqm chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
6} A plate rating reduction of 20% has been applied for the green lumber members.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9} This truss has been designed for a total drag load of 1000 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33} Connect truss to resist drag loads along bottom chord
from 29-6-0 to 36-6-0 for 142.9 plf.
1 O} "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
ENGINEERING
Truss
AA07
'fruss Type
COMMON
Qty
3
Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 0212:38:03 2016 Page 1 ID:ZKw9l?x7pMrCN8?W4AMGRDzHVMu-aJnRpn35S72AVCtYRoqbBJp?qNCnMzW4YltWEXzAl5
-1-6-0 7-2-7 13-3-0 19-3-9 26-9-11 29-11-0 31-5-0 3
1-6-0 7-2-7 6-0-9 6-0-9 7-6-2 3-1-5 1-6-0
Scale .. 1:53
4>16 II
4)6= 4x6 = 3X4 ll 3x4= 3X4 11 4x6= 3x4= 11
3x4= 3x5= 3x4=
3-2-14 9-5-0 17-1-0 23-3-2 29-11-0
3-2-14 6-2-2 7-7-15 6-2-2 6-7-14
Plate Offsets X 2:0-3-0 0-1-12
LOADING (psi) SPACING 2-0-0 CSI DEFL in (Ice) I/dell Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.88 Vert(LL) -0.06 12-14 >999 360 MT20 220/195
TCDL 14.0 Lumber Increase 1:25 BC 0.52 Vert(TL) -0.1714-18 >999 240
BCLL 0.0 * Rep Stress Iner YES WB 0.75 Horz(TL) 0.06 11 n/a n/a
BCDL 10.0 Code IBC2012/TPl2007 (Matrix-M) Wind(LL) 0.03 14 >999 240 Weight: 206 lb FT=20%
LUMBER
TOP CHORD 2x4 OF No.2 G *Except*
T3: 2x4 OF No.1&Btr G
BOT CHORD 2x4 OF No.2 G *Except*
82: 2x6 OF No.2 G
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF No.1 &Bir G *Except*
W6,W1 ,W2,W8,W7: 2x4 OF Stud/STD G
REACTIONS (lb/size) 20=1486/0-3-8 (min. 0-1-10), 11=1473/0-3-8 (min. 0-1,9)
Max Herz 20=-319(LC 8)
Max Uplift20=-105(LC 10), 11=-120(LC 10)
Max Grav20=1501(LC 17), 11=1473(LC 1)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
1 Rowatmidpt 6-14,6-12,4-18,4-19,2-20
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
TOP CHORD 2-21=-799/138, 3-21=713/154, 3-4=-645/177, 4-22=,1245/183, 5-22=1159/220, 5-23=-1308/229, 6-23=-1395/190, 6-24=-1269/168,
7-24=1274/140, 7-8=-1361/120, 2-20=-1481/140, 9-11=-319/184
BOT CHORD 19-20=251/261, 19-26=0/1137, 26-27 =0/1137, 18-27=0/1137, 17-18=0/1065, 17-28=0/1043, 16-28=0/1048, 16-29=0/1066, 15-29=0/1060,
14-15=0/1065, 14-30=0/1284, 30-31=0/1284, 13-31=0/1284, 12-13=0/1284, 11-12=0/841
WEBS 5-14=50/669, 6-14=-319/198, 6-12=-282/0, 8-12=0/543, 5-18=-32127 4, 4-19=-889/0, 2-19=0/1104, 8-11 =-1519/45
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vul1=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BQDL=6.0psf; h=25ft; B=40ft; L=30ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) 120.0lb AC unit load placed on the bottom chord, 23-3-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
6) A plate rating reduction of 20% has been applied for the green lumtier members.
7) This truss is designed in accordance with the 2012 International Building Cqde section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
ENGINEERING
Truss
AAOS
Truss Type
Common
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct 23 2013 Mffek Industries, Inc. Thu Jun 0212:38:04 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-2WLq07 4jDRA 17MSl?VMqjWMCRn Yj5NrnDn Pd4rn_zAI5
1-6-3-11-10 9-8-5 17-2-7 23-3-0 29-3-9 36-9-11 39-11-0 41-5-41
1-6-0 3-11-10 5-8-10 7-6-2 6-0-9 6-0-9 7-6-2 3-1-5 1-6-0 4
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
10-1-12
4-2-12
:0-3-0 0-2-3
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
13-2-14
3-1-2
4x6=
3>6=
CSI
19-5-0
6-2-2
TC 0.70
BC 0.54
WB 0.94
(Matrix-M}
5ld:i=
4x6= 4x6= 4x6= 4:di=
27-1-0
7-7-15
DEFL In (loc} I/dell
Vert(LL} -0.07 14-16 >999
Vert(TL} -0.19 19-21 >999
Horz(TL} O.o7 13 n/a
Wind(LL} 0.04 16 >999
Scale•1 fJ.
3x6=
4x5=
33-3-2 39-11-0
6-2-2 6-7-14
Ud PLATES GRIP
360 MT20 220/195
240
n/a
240 Weight: 244 lb FT=20%
TOP CHORD 2x4 DF No.1 &Bir G
BOT CHORD 2x4 DF No.2 G *Except*
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 4-4-5 oc purlins, except end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
83: 2x6 DF No.2 G
WEBS 2x4 DF No.1 &Bir G *Except'
W2,W1,W4,W9,W8: 2x4 DF Stud/STD G
REACTIONS All bearings 10-5-8 except Ut=length} 13=0-3-8.
(lb} -Max Horz2=331 (LC 25)
Max Uplift All uplift 100 lb or less atjoint(s} 22 excepl2=-242(LC 27), 23=-272(LC 27), 13=363(LC 28)
1 Row at midpt 8-16, 8-14, 6-19, 6-21
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
Max Grav All reactions 250 lb or less atjoint(s} 2 except 2=340(LC 39}, 23=1517(LC 15), 22=650(LC 15}, 13=1586(LC 16)
FORCES (lb} -Max. Comp./Max. Ten. -All forces 250 (lb} or less except when shown.
TOP CHORD 2-28=-455/631, 3-28=-353/590, 3-29=-365/670, 4-29=-186/644, 4-5=-1202/480, 5-30=-1111/403, 6-30=-1110/402, 6-31=-1465/384,
7-31=-1380/311, 7-32=1486/312, 8-32=-1574/277, 8-33=-1409/242, 9-33=-1413/246, 9-10=-1501/321, 11-13=-318/182
BOT CHORD 2-23=-620/531, 22-23=-473/905, 21-22=-473/905, 20-21 =-279/1366, 20-35=-279/1366, 35-36=-279/1366, 19-36=279/1366, 18-19=-205/1193,
18-37 =-205/1193, 37-38=-205/1193, 17-38=-205/1193, 16-17=-205/1193, 15-16=206/1408, 15-39=206/1408, 14-39=-206/1408, 13-14=-124/904
WEBS 7-16=-138/656, 8-16=-315/285, 8-14=-327/123, 10-14=43/598, 7-19=-78/444, 6-21=603/47, 4-24=0/390, 21-24=0/794, 4-23=-1572/345,
3-23=389/119, 22-24=-566/60, io-13=-1634/332
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust} Vasd=B7rnph; TCDL=B.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=40ft; eave=5ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1} zone; cantilever left and right exposed ; end verti~I left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3} 120.0lb AC unit load placed on the bottom chord, 23-3-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 10.0psf.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) This truss is designed in accordance with the 2012 International Building Code sectjon 2306.1 and referenced standard ANSI/TPI 1.
B) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9} This truss has been designed for a total drag load of 1000 lb. Lumber DOL=(1.33} Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord
from 0-0-0 to 10-0-0 for100.0 plf.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S} Standard
Job
ENGINEERING
Truss
AA09
Truss Type
COMMON
Qty
3
Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run:7.500 s Oct 23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 0212:38:06 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-_uSaRp5zl2QIMgc76wOlpxRVRaBKZP8WEj6BrszAl5
1-6-3-11-10 9-8-5 17-2-7 23-3-0 29-3-9 36-9-11 39-11-0 41-5-41
1-6-0 3-11-10 5-8-10 7-6-2 6-0-9 6-0-9 7-6-2 3-1-5 1-6-0 4
4>.fi=
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
3x6=
13-2-14
7-3,14
19:0-0-4 0-2-0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
4ll6=
4ll5=
CSI
19-5-0
6-2-2
TC 0.86
BC 0.72
WB 0.44
(Matrix-M)
Scale-167
Sx6=
4x6= 4ll6= 4x6= 4)8= 4,s:::;
4x6=
27-1-0 33-3-2 39-11-0
7-7-15 6-2-2 6-7-14
DEFL in (Ice) 1/defl Ud PLATES GRIP
Vert(LL) -0.16 19-21 >999 360 MT20 220/195
Vert(TL) -0.58 21-22 >826 240
Horz(TL) 0.18 13 n/a n/a
Wind(LL) 0.13 21-22 >999 240 Weight: 239 lb FT=20%
TOP CHORD 2x4 DF No.1 &Btr G
BOT CHORD 2x4 DF No.2 G *Except*
BRACING
TOP CHORD
BOTCHORD
WEBS
Structural wood sheathing directly applied or 2-2-0 cc purlins, except end verticals.
Rigid ceiling directly applied or 10-0-0 cc bracing.
83: 2x6 DF No.2 G
WEBS 2x4 DF No.1&Btr G *Except*
W2,W1 ,W7,W6: 2x4 DF Stud/STD G
REACTIONS (lb/size) 2=1912/0-5-8 (min. 0-2-1), 13=1930/0-3-8 (min. 0-2-1)
Max Horz2=312(LC 9) .
Max Uplift2=-156(LC 10), 13=-139(LC 10)
FORCES (lb) -Max. Comp./Max. Ten. -All /orces 250 (lb) or less except when shown.
1 Row at midpt 8-16, 8-14, 6-19, 10-13
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
TOP CHORD 2-26=3714/199, 3-26=3675/220, 3-27=3541/191, 4-27=-3430/215, 4-5=-3009/193, 5-28=·2918/214, 6-28=·2917/241, 6-29=-2409/232,
7-29=2323/270, 7-30=-2028/258, 8-30=·2114/220,.8-31 = 1806/190, 9-31=-1810/162, 9-10=-1898/142, 11-13=-320/182
BOT CHORD 2-22=-137/3488, 21-22=67/3162, 20-21=0/2463, 20-33=0/2463, 33-34=0/2463, 19-34=0/2463, 18-19=0/1788, 18-35=0/1788, 35-36=0/1788,
17-36=0/1788, 16-17=0/1788, 15-16=0/1897, 15-37=0/1897, 14-37=0/1897, 13-14=0/1142
WEBS 7-16=-421532, 8-14=-549/0, 10-14=0/853, 7-19=·75/1272, 6·19=-913/223, 6·21=-62/718, 4-21=·606/173, 4-22=0/401, 3-22=-302/109,
10-13=-2069/68
I NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vult=11 Omph-(3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=40ft; eave=5ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) 120.0lb AC unit load placed on the bottom chord, 23-3-0 from 11)11 end, support09 at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsl.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) This truss is designed in accordance with the 2012 lntjlrnational Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
ENGINEERING
Truss
AA10
Truss Type
Common
Qty Ply 24190·Bowling Residence·michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 02 12:38:07 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-T50ye96bWMYc_pBKgevXL9_hY_cllsEgTNrkNlzAl5
-1-6-0 3-11-10 9-8-5 17-2-7 23-3-0 29-3-9 31-9-0
1-6-0 3-11-10 5-8-10 7-6-2 6-0-9 6-0-9 2-5-7
4x5 11
28 29 14 30
13-2-14
3-2-14
19-5-0 22-0-0 27-1-0 128-9·81 31-9-0
6-2-2 2-7-0 5-1-0 1-8-8 2-11-8
16:0-1-0 0-1-12
LOADING (psi)
TCLL 20.0
SPACING 2·0·0
Plates Increase-1.25
CSI
TC o.n DEFL in (foe) I/dell Ud PLATES GRIP
Vert(LL) -0.09 12-14 >999 360 MT20 220/195
TCDL 14.0 BC 0.42 Vert(TL) -0.22 12-14 >513 240
BCLL 0.0 • Horz(fl) 0.03 14 n/a n/a
BCDL 10.0
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/fPl2007
WB 0.45
(Matrix-M) Wind(LL) 0.0416·17 >999 240 Weight: 193 lb FT=20%
LUMBER
TOP CHORD 2x4 DF No.1 &Bir G *Except•
T3: 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
WEBS 2x4 DF No.1 &Btr G *Except•
W2,W1 ,W7,W6: 2x4 DF Stud/STD G
REACTIONS All bearings 12-0·0 except Qt=length) 2=0·5·8, 10=3-3·0, 11 =0·3·8.
(lb) -Max Horz2=404(LC 26)
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 5· 1-2 cc purlins, except end verticals.
Rigid ceiling directly applied or 5-3·2 cc bracing.
1 Row at midpt 7·12, 8·12, 7-14, 6-14, 6-16, 8-10
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
Max Uplift All uplift 100 lb or less atjoint(s) 11 except 14=-227(LC 28), 16~1302(LC 27), 2~661(LC 27), 10~901(LC 28)
Max Grav All reactions 250 lb or less atjoint(s) 11 except 14=931(LC 15), 16=1859(LC 24), 2=879(LC 24), 10=1142(LC 25)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-21 =-1732/1297, 3·21 =-1394/1139, 3·22=-1276/890, 4-22=-7 44/630, 4-5=-5047648, 5·23=-95/389, 6-23=·449/735, 6-24=·609/631 ,
7-24=-186/320, 7-25=·527/553, 8·25=-481/395, 8-26=-333/365
BOT CHORD 2-17=-1310/1643, 17-27=-1380/1358, 16-27=·1380/1358, 15-16=-1200/1111, 15·28=·1031/942, 28·29=·430/341, 14-29=-723/634,
14·30=-402/427, 13·30=·814/839, 13·31=-814/839, 12-31=-814/839, 12-32=·321/382, 11 ·32=·321 /382, 11-33=·321 /382, 10-33=-321/382
WEBS 7-12=-759/900, 8-12=·742/837, 7-14=-950/637, 6-14=·912/951, 6·16=·1586/1395, 4-16=·646/187, 4·17=-27/481, 3-17=·363/143,
8· 10=-1183/930
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vult=110mph (3·second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=32ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C·C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load ·of 20.0psf on the bottom chord in all areas where a rectangle 3·6·0 tall by 2-0·0 wide will fit between the bottom chord
and any other members, with BQDL = 10.0psf. •
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the·2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) This truss has been qesigned for a total drag load of 3000 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord
from 1 O·O·O to 22·0·0 for 250.0 plf.
9) "Semi·rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
ENGINEERING
Truss
AA11
Truss Type
Common
Qty Ply 24190-Bowhng Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 Milek Industries, Inc. Thu Jun 0212:38:08 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-xHaKsV7DHggTczmWELQmuMXs?Oyl1 EYpi1 bHwlzAl5
-1-6-0, 3-11-10 9-8-5 17-2-7 23-3-0 29-3-9 31-9-0
1-6-0 3-11-10
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
5-8-10
10:0-1-8 0-1-8
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012frPl2007
13-2-14
7-3-14
CSI
TC 0.79
BC 0.40
WB 0.76
(Matrix-M)
7-6-2 6-0-9 6-0-9 2-5-7
Scala .. 1.52.
""'"
3x4=
19-5-0 21-9-4 2~9.-0 27-1-0 31-9-0
6-2-2 2-4-4 0--12 5-1-0 4-8-0
DEFL in (loc) 1/defl Ud PLATES GRIP
Vert(LL) -0.0714-16 >999 360 MT20 220/195
Vert(TL) -0.2416-17 >999 240
Horz(TL) 0.03 13 n/a n/a
Wind(LL) 0.0416-17 >999 240 Weight: 207 lb FT=20%
TOP CHORD 2x4 DF No.1 &Bir G *Except*
T3: 2x4 DF No.2 G
BRACING
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 5-4-9 oc purlins, except end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
BOT CHORD 2x4 DF No.2 G
WEBS 2x4 DF No.1&Btr G *Except*
W2,W1 ,W8,W7: 2x4 DF Stud/STD G, W6: 2x4 DF No.2 G
REACTIONS (lb/size) 2=943/0-5-8 (min. 0-1-8), 10=149/Mechanical, 13=1795/0-5-8 (min. 0-2-0)
Max Herz 2=376(LC 9)
Max Uplift2=·126(LC 10), 10=·28(LC 10), 13=-137(LC 10)
Max Grav2=943(LC 1), 10=328(LC 26), 13=1864(LC 15)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
1 Rowatmidpt 8-11,6-14, 7-13,8-10
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
TOP CHORD 2-21 =-1532/131, 3-21 =-1449/152, 3·22=· 1329/124, 4-22= 1182/147, 4-5=-696/137, 5-23=-604/158, 6-23=-604/185
BOT CHORD 2-17=-152/1397, 16-17=-102/966, 13-14=-430/194, 13-29=-265/177, 12-29=-265/177, 11-12=-265/177
WEBS 7-11=64/410, 8-11=261/118, 7-14=-166/1037, 6-14=-920/217, 6-16=56/748, 4-16=633/175, 7-13=-1705/178, 4-17=0/454, 3-17=-346/110,
8-10=·256/49
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=32ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C.lnterior(1) zone; cantilever left and right exposed; end vertical-left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live lo,ids.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 10.0psf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) Refer to girder(s) for truss to truss connections.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
ENGINEERING
Truss
AA12
Truss Type
California
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 02 12:38:08 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-xHaKsV7DHggTczmWELQmuMXq50XS1 Fopi1 bHwlzAl5
1-1-6-o I
1-6-0
LOADING (psij
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
7-4-12
7-4-12
14-2-10
6-9-13
14-2-10
6-9-13
6:0-4-4 0-1-4 8:0-3-0 0-1-12 14:0-4-0 0-3-0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
CSI
TC 0.91
BC 0.49
WB 0.68
(Matrix-M)
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
BRACING
21-3-5
7-0-11
21-3-5
7-0-11
in (foe)
-0.0713-14
-0.2413-14
O.o7 9
0.05 9-10
I/dell
>999
>999
n/a
>999
21-9-4
21 f8l~ 1 24.9.5 25i2l 11
0-5-6 3-0-1 0-5-6
0-0-9
S>:8=
21-~-4
0-5-15
Ud
360 240
n!a
240
21
T3
25-2-11
3-5-7
PLATES
MT20
Weight: 188 lb
31-5-8
6-2-13
B3
25
31-9-0
6-6-5
GRIP
220/195
FT=20%
Scale•1.53
3x4!1
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and
0-0-0 oc purlins (6-0-0 max.): 6-7.
WEBS 2x4 DF No.2 G *Except*
W1 ,W2,W3,W8: 2x4 DF Stud/STD G
REACTIONS (lb/size) 9=648/Mechimical, 2=1180/0-5-8 (min. 0-1-8), 12=1060/0-5-8 (min. 0-1-8)
Max Herz 2=360(LC 9)
Max Uplift9=·53(LC 10), 2=·139(LC 10), 12=-99(LC 10)
Max Grav9=774(LC 16), 2=1180(LC 1), 12=1160(LC 15)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing.
WEBS 1 Row at midpt 5-13, 7-10, 6-12
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
TOP CHORD 2-19~1838/129, 3-19=-1741/153, 3-4=·1216/126, 4-5=·1067/169, 5-20=-541/155, 6-20=-444/180, 6-21=·367/195, 7-21=·374/193,
7-22=·397/181, 8-22=-476/159, 8-9=-648/93
BOT CHORD 2-15=-146/1818, 14-15=·111/1616, 14-23=-61/1027, 23-24=·61/1027, 13-24~61/1027, 12-13=·53/330, 11-12=-53/317, 10-11=·53/317
WEBS 3-15=0/260, 3-14=·668/117, 5-14=0/534, 5-13=·995/175, 6-13=0/475, 7-10=·254/74, 8-10=0/421, 6-12=·630/0
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vult=110mph (3-secpnd gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=4011; L=32ft; eave=4fl; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any o_ther live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) Refer to girder(s) for tryss to truss connections.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
1 OJ "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job
ENGINEERING ,.
Truss
AA13
Truss Type
California
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 02 12:38:09 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-PT8j3r7s2zpKD7Lio3x?Qa30ooD6mmEyxhKrSBzAl5
6-10-10
6-10-10
14-0-11
7-2-0
19-3-5 19f8-11 23-3-0 26-9-5 27-2-11 31-5-8 31r,9-0
5-2-1 o o-516 3-6-5 3-6-5 ol5l5 4-2-13 o-3~8
Scale•l.53
19-3-5 21-9-4 27-2-11 31-9-0
9-7-11 2-5-15 5-5-7 4-6-5
6:0-3-0 0-1-12 9:0-3-0 0-1-12
LOADING (psi) SPACING 2-0-0 CSI DEFL in (Ice) Vdefl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.85 Vert(LL) -0.23 14-16 >999 360 MT20 220/195
TCDL 14.0 Lumber Increase 1.25 BC 0.65 Vert(TL) -0.5514-16 >476 240
BCLL 0.0 • Rep Stress Iner YES WB 0.42 Horz(TL) 0.03 13 n/a n/a
BCDL 10.0 Code IBC2012/TPl2007 (Matrix-M) Wind(LL) 0.03 16 >999 240 Weight: 198 lb FT=20%
LUMBER BRACING
TOP CHORD 2x4 OF No.2 G
BOT CHORD 2x4 OF No.2 G
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and
0-0-0 oc purlins (6-0-0 max.): 6-8. Except:
6-0-0 oc bracing: 6-8 WEBS 2x4 OF No.2 G *Except•
W1,W2,W3,W9,W8: 2x4 OF Stud/STD G-BOT'CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1Rowatmidpt 5-14,6-13,7-13,8-11
REACTIONS (lb/size) 2=895/0-5-8 (min. 0-1-8), 13=1971/0-5-8 (min: 0-2-3), 10=21/Meclianical
Max Horz 2=339(LC 9)
Max Uplift2=-111(LC 10), 13=·186(LC 10), 10=·87(LC 21)
Max Grav2=895(LC 1), 13=2052(LC 15), 10=244(LC 26)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-20=·1355/104, 3-20~1041/132, 3-21~885/108, 4-21=-791/108, 4-5=-776/134, 6-23=·10/504, 7-23=-10/504
MiT ek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
BOT CHORD 2-16=·122/1696, 16'26~105/397, 15·26=·105/397, 15-27=-105/397, 14-27=-105/397, 13-14=-257/176, 13-28=-370/172, 12-28=-370/172,
12-29=-370/172, 11-29~370/112
WEBS 3-16~460/178, 5-16=-17/722, 5-14=·813/181, 6-14=·46/865, 6-13=-1219/90, 7-13=-843/121, 7-11=-39/605, 8-11=·347/70
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vull=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=4011; L=32ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber D0L=1.33 plate grip D0L=1.33
3) Provide adequate drainage IQ prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live· load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) Refer to girder(s) for truss to truss connections.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
1 OJ "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord,
LOAD CASE(S) Standard
Job Truss
ENGINEERING AA14
Truss Type
California
Qty Ply 24190-Bowfing Residence-michaelc
Job Reference o tional California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 0212:38:10 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-tgi5HA8UpHxArHwulmSEzncCXBbtV7D69L40_dzAl5
1 -1-6-0 I
1-6-0
6-0-6
6-0-6
11-6-12
5-6-6
17-3-5 17ra111 23-3-o 2a-9-5 29r2-1131-5-831-9-o
5-8-8 o-5-6 5-6-5 5-6-5 o-sl6 2-2-13 o!aL8
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 •
BCDL 10.0
LUMBER
9-1-12
9-1-12
6:0-3-0 0-1-12
SPACING 2-0-0
Plates Increase 1.25
Lumber-Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
17-3-5
8-1-8
CSI DEFL
TC 0.79 Vert(LL)
BG 0.55 Vert(TL)
WB 0.82 Horz(TL)
(Matrix-M) Wind(LL)
BRACING
ScaJe .. 1 54
sxa-:::::-
21-9-4 29-2-11 31-9-0
4-5-15 7-5-7 2-6-5
in (foe) I/dell lid PLATES GRIP
-0.08 14-16 >999 360 MT20 220/195
-0.28 16-19 >937 240
0.03 13 n/a n/a
0.03 16 >999 240 Weight: 189 lb FT=20%
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
TOP CHORD Struclural wood sheathing direclly applied or 5-2-7 oc purlins, except end verticals, and
0-0-0 oc purlins (6-0-0 max.): 6-8. Except:
6-0-0 oc bracing: 6-8 WEBS 2x4 DF Stud/STD G *Except'
W5,W7: 2x4 DF No.2 G BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Rowatmidpt 6-13, 7-13
REACTIONS (lb/size) 2=897/0-5-8 (min. 0-1'8), 13=1960/0-5-8 (min. 0-2-3), 10=30/Mechanical
Max Herz 2=320(LC 9)
Max Uplift2=-115(LC 10), 13=-172(LC 10), 10=-79(LC21)
Max Grav2=897(LC 1), 13=2068(LC 15), 10=247(LC 26)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
MiTek recommends that Stabilizers and required cross bracing be installed during
truss ereclion in accordance with Stabilizer Installation uide.
TOP CHORD 2-20~ 1240/108, 3-20=-1165/141, 3-21=-930/105, 4-21 =-850/106, 4-5=-789/126, 6-23~31 /534, 23-24=-31 /534, 7-24=-31 /534, 9-10=-256/68
BOT CHORD 2-16~128/1513, 16-27~106/640, 27-28=-106/640, 15-28=-106/640, 14-15=-106/640, 13-30=-365/144, 12-30=-365/144, 12-31=-365/144,
11-31~365/144
WEBS 3-16=-405/142, 5-16=0/510, 5-1~756/151, 6-14=-32/697, 6-13=-1147/110, 7-13=-899/151, 7-11=-20/563, 8-11=-338/107
NOTES
1) This truss has been checked for uniform roof live load only, except as noled.
2) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=B.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=32ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (direclional) and C-C lnterior(1) zone; cantilever left and right exposed ;·end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
6) A plate raling reduclion of 20% has been applied for the green lumber members.
7) Refer to girder(s) for truss to truss conneclions.
B) This truss is designed in accordance with the 2012 lnternalional Building Code seclion 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been-designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job \
ENGINEERING
Truss
AA15
Truss Type
California
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional · ·california TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23-2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:11 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-LsGTUW96ab31TRV5vU_TW?9LzbyZDhmFOJJyW4zAl5Q
31-9-0
I -1-6-o I
1-6-0
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
7-10-7
7-10-7
14:0-2-8 0-2-0
SPACING 2-0-0
Plates Increase· 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
15-3-5
7-4-14
15-3-5
9-8-13
CSI
TC 0.94
BC 0.46
WB 0.35
(Matrix-M)
21-9-4
0-5-6 6-0-9
22 23
82
27
21-9-4
6-5-15
DEFL in (loc) I/dell
Vert(LL) -0.1811-13 >644
Vert(TL) -0.55 14-16 >476
Horz(TL) 0.02 13 n/a
Wind(LL) 0.03 16 >999
BRACING
26-5-11
4-8-7
3ld3= 3x4:::::
133x4 = 3x4=
31-0-15
9-3-11
Ud PLATES
360 MT20
240
n/a
240 Weight: 178 lb
30-9-5
4-3-10
GRIP
220/195
FT=20%
31-5-8
31fr15I 0--'ldSoaJ,-1'54
0-4-9
0-3-8
11 10
3x4 Ii
5~=
SJ-9~0 -8-
"1.
;[.·
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.1 &Bir G
WEBS 2x4 DF Stud/STD G *Except*
W4,W6,W7: 2x4 DF No.2 G
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and
0-0-0 oc purlins (6-0-0 max.): 5-8. Except:
REACTIONS (lb/size) 2=875/0-5-8 (min. 0-1-8), 10=-17/Mechanical, 13=2029/0-5-8 (min. 0-2-5)
Max Herz 2=303(LC 9)
Max Uplifl2=-140(LC 10), 10=-119(LC 29), 13=-100(LC 10)
Max Grav2=875(LC 1), 10=195{LC 26), 13=2148{LC 15)
FORCES {lb) -Max. Comp./Max. Te11. -All forces 250 {lb) or less except when shown.
6-0-0 oc bracing: 5-8
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row al midpt 3-14, 6-13, 7-13
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
TOP CHORD 2-20=-1237/141, 3-20=-1051/99, 3-4=-341/115, 6-24=0/669, 24-25=0/669, 7-25=0/669, 8-9=-256/160, 9-10=-402/122
BOT CHORD 2-16=319/1439, 15-16=-165/911, 14-15= 165/911, 14-27=-676/101, 13-27 =-676/101; 12-13=-271/83, 12-28=-271 /83, 28-29=271/83,
11-29=271/83
WEBS 5-14=-344/78, 8-11=-89/268, 3-14=-788/174, 3-16=0/430, 6-13=-1257/168, 6-14=-68/-1157, 7-13=-n3/33, 7-11=0/452
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vult=110mph {3-second gust) Vasd=87niph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft;.L=32fl; eave=4fl; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load no_!lconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) Refer to girder(s) for truss to truss connections.
8) This truss is designed in accordance with the.2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
1 OJ "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job -.,
ENGINEERING
Truss
AA16
Truss Type
Roof Special
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 02 12:38:11 2016 Page 1
ID:ZKw9I?x7pMrCNB?W4AMGRDzHVMu-LsGTUW96ab31TRV5vU_TW?90kbypDa?FO__pyW4zAl5Q
7-5-6
7-5-6
13-3-5
5-9-14
13i8i11 17-6-4 21-9-4 26-8-4 31-5-8 31,-~-0
o-5-6 3-9-9 4-3-o 4-11-0 4-9-4 023-8
j
..
3>S=
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL a.a.
BCDL 10.0
LUMBER
5.5-0[12
13-3-5
7-5-13
14:0-2-8 0-2-0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
CSI
TC 0.76
BC 0.51
WB 0.78
(Matrix-M)
4x8=
21-9-4
8-5-15
DEFL in (lac)
Vert(LL) -0.1312-14
Vert(TL) -0.3112-14
Horz(TL) 0.03 12
Wind(LL) 0.03 16-19
BRACING
2X4 II
I/dell Ud
>999 360
>843 240
n/a n/a
>999 240
83
26-8-4
4-11-0
PLATES
MT20
3x8=
11
2><411
Weight: 174 lb
31-9-0
5-0-12
GRIP
220/195
FT=20%
Scale•1:53
2x4 II
10
3x4 =
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
TOP CHORD Structural wood sheathing directly applied or 3-8-2 oc purlins, except end verticals, and
0-0-0 oc purlins (6-0-0 max.): 5-9. Except:
WEBS 2x4 DF Stud/STD G 6-0-0 oc bracing: 5-9
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 6-12
REACTIONS (lb/size) 10=66/Mechanical, 2=914/0-5-8 (min. 0-1-8), 12=1907/0-5-8 (min. 0-2-1)
Max Herz 2=266(lC 9)
Max Uplift10~61(LC 7), 2=-124(LC 10), 12=-155(LC 10)
Max Grav10s:282(LC 26), 2=914(LC 1), 12=1907(LC 1)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-20~ 1278/78, 3-20=· 1181/94, 3-4=-604/91, 4-21=-522/107, 5-21 ~511/128, 5·22=·462/138, 6-22=·465/137,
6-23=-46/560,.23-24=·46/560, 7-24=-46/560, 7-25=-46/560, 25-26=-46/560, 8-26=-46/560, 9-10=-308/55
BOT CHORD 2-16~209/1494, 15-16=-108/1015, 14-15~108/1015 -
WEBS 3-14=-634/146, 3-16=0/288, 7-12=-376/101, 8-12=-743/68, 6-14=-21/723, 6-12=-1071/123
NOTES
1) This truss has been checked for uniform roof live load only, except as noted. .
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=32ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 1 o.o psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) Refer to girder(s) for truss to truss connections.
8) Thi.s truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job ..,
ENGINEERING
Truss
AB01
Truss Type
CALIFORNIA GIRDER
Qty Ply 24190-Bowltng Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 Milek Industries, Inc. Thu Jun 0212:38:12 2016 Page 1
ID:ZKw9l?x7pMrCN8?W4AMGRDzHVMu-p2qrhsAkluBu4b3HTBVi2ChX9?Cgy8kPdeZV3WzAl5
I -1-6-o I 3-11-3 7-6-5 11-0-0
1-6-0 3-11-3 3-7-1 3-0-5
I 14-0-5 1 d-5-? 1 18-0-13 I 21-8-8 2j-o-o 23-6-o I
-3-7-1 3-7-11 0-318 1-6-0
7-6-5
3-7-1
6:0-6-8 0-1-5 8:0-2-11 0-1-8
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x6 DF No.2 G
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner NO
Code IBC2012/TPl2007
WEBS 2x4 DF Stud/STD G
CSI
TC 0.84
BC 0.85
WB 0.37
(Matrix-M)
11-0-0
3-5-11
12
2X4 II
14-5-11
3-5-11
DEFL in (Joe)
Vert(LL) -0.13 12
Vert(TL) -0.45 12
Horz(TL) 0.14 8 Wind(LL) 0.16 12
BRACING
I/dell
>999
>587
n/a
>999
18-0-13 22-0-0
3-7-1 3-11-3
Ud PLATES GRIP
360 MT20 220/195
240
n/a
240 Weight: 122 lb FT=20%
TOP CHORD Structural wood sheathing directly applied or 2-6-2 oc purlins, except
0-0-0 oc purlins (2-5-1 o max.): 4-6. Except:
2-6-0 oc bracing: 4-6
BOT CHORD Rigid ceiling directly applied or 8-2-13 oc bracing.
Scale-1400:
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 2=2251/0-5-8 (min. 0-2-11), 8=2251/0-5-8 (min. 0-2-11)
Max Horz2=-73(LC 6)
Max Uplift2=-441(LC 8), 8=441(LC 8)
Max Grav2=2491(LC 13), 8=2491 (LC 14)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-20=-5205/876, 2-21=-5230/916, 3-21~5201/927, 3-22=-4877/1025, 4-22=-4842/1038, 4-23=-4406/961, 23-24=-4410/960, 5-24=-4417/960,
5-25=-4417/960, 25-26=-4410/960, 6-26=-4406/961, 6-27=-484211038, 7-27=487711025, 7-28=05200/927, 8-28=-5229/916, 8-29=-5205/876
BOT CHORD 2-15=-754/4781, 14-15=754/4781, 14-30=-921/4965, 13-30=-921/4965, 12-13~921/4965, 12-31=-921/4965, 11-31=921/4965, 10-11=-754/4730,
8-10=-754/4730
WEBS 3-14=-523/0, 4-14=-4/935, 5-14= 779/175, 5-11 = 778/175, 6' 11 =-4/935, 7-11 =-523/0
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vu)t=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional); cantilever left-and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) A plate rating reduction of 20% has ~en applied for the green lumber members.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb live located at all.mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) Girder carries hip end with 8-0-0 end setback.
1 OJ "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 858 lb down and 328 lb up at 14-5-12, and 858 lb down and
328 lb up at 7-6-4 on top chord. The design/selection of such connection device(s) is the responsibility of others.
13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25
Uniform Loads (plf)
Vert: 1-4=-68, 4-23=-68, 23-26=-162, 6-26=-68, 6-9=·68, 2-8=-48(F=-28)
Concentrated Loads (lb)
Vert: 4=-589 6=-589
Job -.,
ENGINEERING
Truss
AB02
Truss Type
California
Qty Ply 24190-Bowling Residence-michaelc
Job Reference a t,onal
California T rusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:13 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-HFNDvCBM6CJlikeT1uOxbQEmlPcFhdzYrll2byzAl5
-1-6-o I 4-8-14 9-6-5
1-6-0 4-8-14 4-9-7
s-~H-1 12-0-5 12-5-~1 17-3-2 21-8-8 22-o-02s-6-o I
o-5-7 2-0-10 o-5-7 4-9-7 4-5-6 ols18 1-6-o
j
l
LOADING (psi)
TCLL 20.0
TCDL 14.0
3llfi=
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
9-6-5
9-6-5
1-1 :0-2-0 0-1-8
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
WEBS 2x4 DF Stud/STD G
CSI
TC 0.63
BC 0.64
WB 0.24
(Matrix-Ml
4>:B //
12-5-11
2-11-7
DEFL in
Vert(LL) -0.12
Vert(TL) -0.41
Horz(TL) 0.07
Wind(LL) 0.05
BRACING
TOP CHORD
BOTCHORD
22-0-0
9-6-5
(lac) Vdefl Ud PLATES GRIP
9-17 >999 360 MT20 220/195
9-17 >638 240
7 n/a n/a
9-11 >999 240 Weight:99 lb FT=20%
Structural wood sheathing directly applied or 4-5-0 oc purlins, except
0-0-0 oc purlins (5-9-8 max.): 4-5.
Rigid ceiling directly applied or 10-0-0 oc bracing.
Scale• 1'40
3x6=
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 2=1074/0-5-8 (min. 0-1-8), 7=1074/0-5-8 (min. 0-1-8)
Max Herz 2=88(LC 9)
Max Uplift2=-139(LC 10), 7=-139(LC 10)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-18=-1729/206, 3-18=-1628/231, 3-19=-1345/149, 4-19~1270/166, 4-20~1153/174, 5-20=-1158/173, 5-21=-1295/167, 6-21=-1368/150,
6-22=-1631/232, 7-22=-1732/207
BOT CHORD 2-11 =-115/1526, 10-11 =0/1182, 9-10=0/1182, 7-9=-116/1530
WEBS 3-11=-468/148, 4-11=0/335, 5-9=0/290, 6-9=-4421144
NOTES
1) This truss has been checked for uniform roof live load only, except as noted ..
2) Wind: ASCE 7-1 0; Vult=110mph (3-second gust) Vasd=87mph; TCDL=B.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1J zone; cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4J This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20:0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6J A plate rating reduction of 20% has been applied for the green lumber members.
7J This truss is designed in accordance with the 2012. International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
BJ This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
1 OJ Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job -,
ENGINEERING
Truss
·ABOS
Truss Type
Common
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional
-California Trusframe LLC., Perris, CA. 92570
I -1-6-0 5-0-4
1-6-0 5-0-4
11-0-0
5-11-12
Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 Milek Industries, Inc. Thu Jun 02 12:38:13 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-HFNDvCBM6CJlikeT1uOxbQEimPe_hdQYrll2byzAl5l I 16-11-12 I 21-8-8 2~-g-023-6-0 I
5-11-12 4-8-12 0-3-8 1-6-0
Scale-1:39
3xS=
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 OF No.2 G
BOT CHORD 2x4 DF No.2 G
7-2-8
7-2°8
10:0-1-8 0-1-8
SPACING 2-0-0 CSI
Plates Increase 1.25 TC 0.85
Lumber Increase 1.25 BC 0.46
Rep Stress Iner YES WB 0.21
Code IBC2012/TPl2007 (Matrix-M}
4x61l
14-9-8
7-7-0
DEFL in
Vert(LL) -0.07 Vert(TL) -0.30
Horz(TL) 0.06
Wind(LL} 0.06
BRACING
TOP CHORD
BOT CHORD
22-0-0
7-2-8
(loc) I/dell Lid PLATES GRIP
8-10 >999 360 MT20 220/195 8-10 >891 240
6 n/a n/a
8-10 >999 240 Weight: 91 lb FT=20%
Structural wood sheathing directly applied or 2-2-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
3>£=
WEBS 2x4 DF Stud/STD G MiT ek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size} 2=1074/0-5-8 (min. 0-1-8), 6=1074/0°5-8 (min. 0-1-8)
Max Horz2=-101(LC 8)
Max Uplift2=139(LC 10), 6=-139(LC 10)
FORCES (lb} -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-17=-1788/172, 3-17=-1677/200, 3-18=1536/169, 4-18=-1447/190, 4-19=-1447/190, 5-19=-1536/169, 5-20=-1677/200, 6-20=-1788/172
BOT CHORD 2-10~87/1577, 9-10=0/1015, 8-9=0/1015, 6-~87/1577
WEBS 4-8=-18/517, 5-8=-387/148, 4-10=-18/517, 3-10=-387/148
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vult=110mph (3-second gust} Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=4011; L:2411; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional} and C-C lnterior(1) zone; cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job -,.
ENGINEERING
Truss
AB04
Truss Type
COMMON
Qty
8
Ply 24190-Bowling Res,dence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570
-1-6-0
1-6-0
5-0-4
5-0-4
11-0-0
5-11-12
Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 Milek Industries, Inc. Thu Jun 0212:38:14 2016 Page 1 J ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-lRxc6YB_sWRcKuDgacXA7dntVo_AQ4fh4y2c70zAl5~
I 16-11-12 I 21-8-8 22-8-0
5-11-12 I 4-8-12 o:3-8
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No,2 G
7-2-8
7-2-8
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
CSI
TC 0.85
BC 0.47
WB 0.21
(Matrix-M)
4x5II
14-9-8
7-7-0
DEFL in
Vert(LL) -0.07
Vert(TL) -0.29
Horz(TL) 0.06
Wind(LL) 0.06
BRACING
TOP CHORD
BOT CHORD
22-0-0
7-2-8
(loc) 1/defl Ud PLATES GRIP
7-9 >999 360 MT20 220/195
7-9 >895 240
6 n/a n/a
7-9 >999 240 Weight:89 lb FT=20%
Structural wood sheathing directly applied or 2-2-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
Scale•1:36.
WEBS 2x4 DF Stud/STD G MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 6=967/0-5-8 (min. 0-1-8), 2=1076/0-5-8 (min. 0-1-8)
Max Horz2=101(LC 9)
Max Uplift6=-80(LC 10), 2=·140(LC 10)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-16=-1791/174, 3-16=-1681/201, 3-17=-1539/170, 4-17~1450/192, 4-18=-1456/195, 5-18~1545/174, 5-19~1688/205, 6-19=-1799/178
BOT CHORD 2-9~126/1579, 8-9=-11/1018, 7-8=-11/1018, 6-7~131/1588
WEBS 4-7=-22/521, 5-7=-389/150, 4-9=-17/517, 3-9~387/148
NOTES
1) This truss has been checked for uniform roof live load only, except as noted. .
2) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012.lnternational Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job ·, Truss
ENGINEERING AC01
Truss Type
California Girder
Qty Ply 24190-Bowling Residence-michaelc
2 Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570
3-11-11
Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:15 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-EdV_KuCcdpZTx2os8J2PgrJ29CH69WprJcn9frzAl5M
7-7-5
3-7-9
11-2-4
3-1-9
14-10-4 17-11-13 18-5-3 22-0-13 25-6-0 25-9-8
3-8-1 3-1-9 d-5-o/ 3-7-9 3-5-3 0!3ls 3-11-11
25
13 12
5x6 WB=
3x6= 3x4=
3-11-11 _ 7-7-5 11-2-4 14-10-4
3-11-11 3-7-9 3-6-15 3-8-1
Plate Offsets X 1 :0-1-12 0-0-11
LOADING (psi) SPACING 2-0-0 CSI DEFL
TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL)
TCDL 14.0 BC 0.61 Vert(TL)
BCLL 0.0 * Horz(TL)
11
2x4 lJ
in (lac)
-0.1211-13
. -0.40 11-13
0.13 8
33
18-5-3
3-6-15
1/defl tJd
>999 360
>766 240
n/a n/a
10
3x8=
22-0-13
3-7-9
PLATES
MT20
2x4 11
25-9-8
3-8-11
GRIP
220/195
BCDL 10.0
Lumber Increase 1.25
Rep Stress Iner Nci
Code IBC2012/TPl2007
WB 0.28
(Matrix-M) Wind(LL) 0.1511-13 >999 240 Weight: 249 lb FT=20%
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.1&Btr G
WEBS 2x4 DF Stud/STD-G
OTHERS 2x4 DF Stud/STD G
REACTIONS (lb/size) 1=2772/0-5-8 (min. 0-1-11), 8=2737/Mechanical
Max Horz 1 =62(LC 7)
Max Uplift1=-564(LC 8), 8=557(LC 8)
Max Grav1=3140(LC 13), 8=3101(LC 14)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shoYJn.
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-0-10 oc purlins, except
0-0-0 oc purlins (4-4-8 max.): 3-6. Except:
4-4-0 oc bracing: 3-6
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
TOP CHORD 1-22=-6487/1273, 2-22=-6413/1292, 2-23=6382/1431, 3-23=-6310/1450, 3-24=-5776/1334, 24-25=-5805/1344, 4-25=5815/1343,
4-26= 7017 /1618, 26-27=-7017/1618, 5-27= 7017/1618, 5-28=-5724/1313, 28-29=-5713/1314, 6-29=5685/1304, 6-30=-6200/1413,
7-30=-6279/1393, 7-31 =-6195/1234, 8-31 =-6269/1215
BOT CHORD 1-15=1122/5861, 14-15=-1122/5861, 14-32=-1506/7032, 13-32=-1506/7032, 12-13=-1510/7022, 11-12=-1510/7022, 11-33=-1510/7022,
10-33=1510/7022, 9-10=1067/5603, 8-9=-1067/5603 -
WEBS 2-14=-253/95, 3-14=-132/1426, 4-14=-1713/392, 4-13=0/275, 5-10=-1848/441, 6-10=-155/1473
NOTES
1) 2-plytruss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered-equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F)·or (B), unless otherwise indicated.
3) This truss has been checked for uniform roof live load only, except as noted;
4) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; l=26ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1 .33
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
8) A plate rating reduction of 20% has been applied for the green lumber members.
9) Refer to girder(s) for truss to truss connections.
10) This truss is designed in accordance with the 2012 International Building Code section 23Q6.1 and referenced standard ANSI/TPI 1.
11) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live load_s.
12) Girder carries hip end with 8-1-0 end setback and tie-in span of 3-0-0 from subgirder.
13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
14) Graphical purlin representation does n_ot depict the size or the orientation of the purlin along the top and/or bottom chord.
15) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1071 lb down and 402 lb up at 17-8-8, and 1071 lb down and
402 lb up at 8-1-0 on top chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25
Uniform Loads (pl!)
Vert: 1-3=-68, 3-24=-68, 4-5=-181, 6-29=-68, 6-8=-68, 16-19=-'48(F=-28)
Concentrated Loads (lb)
Vert: 24=-741 29=-741
Continued on a e 2
Scale•1·41.
4>S=
California TrusFrame LLC., Perris, CA. 92570
LOAD CASE(S) Standard
Trapezoidal Loads (plf)
Vert: 24=-164-to-4=-181, 5~180-to-29=-164
/
Truss Type
California Girder I~~ 'Ply I24190-Bowling Residence-michaelc
2 Job Reference (ootional)
Run: 7.500 s Ocl23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:15 2016 Page 2 ID:ZKw9l?x7pMrCNB?W4AMGRDzHVMu-EdV_KuCcdpZTx2os8J2PgrJ29CH69WprJcn9frzAl5M
Job ')
ENGINEERING
Truss
AC02
Truss Type
California
Qty Ply 24190-Bowhng Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570
4-10-2
Run: 7.500 s Oct23 2013 Print: 7.500 s Oct 23 2013 MiTek lndustrtes, Inc. Thu Jun 0212:38:16 2016 Page 1 ID:ZKw9I?x7pMrCN8 ?W4AMGRDzHVMu-ip3MXEDF07hKZCN2i1 ZeD2s FjcbBuzq_ YGXjCHzAl5
4-10-2
9-7-5
4-9-2
19-0,11
0-5-7
13-0-4
2-11-9
15-11-13 1 ?"5o/ 21-2-6 25-6-0 2~-~-8
2-11-9 0-5-4-9-2 4-3-10 0-3-8
315==
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4·DF No.2 G
BOT CHORD 2x4 OF No.2 G
10:0-2-0 0-1-8
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1:25
Rep Stress Iner NO
Code IBC2012/TPl2007
WEBS 2x4 DF Stud/STD G
3x10=
CSI
TC 0.74
BC 0.75 WB 0.23
(Matrix-M)
4x6~
3x10=
16-5-3 25-9-8
6-9-15 9-4-5
DEFL in (lac) Vdefl Ud PLATES GRIP
Vert(LL) -0.14 8-16 >999 360 MT20 220/195
Vert(TL) -0.46 8-16 >667 240
Horz(TL) 0.10 7 n/a n/a
Wind(LL) 0.08 8-10 >999 240 Weight: 113 lb FT=20%
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-10-5 cc purlins, except
0-0-0 cc purliils (4-10-11 max.): 3-5. Except:
4-11-0 cc bracing: 3-5
BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing.
Scale-1.41.
4x5::::
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 1=1180/0-5-8 (min. 0-1-8), 7=1158/Mechanical
Max Herz 1=78(LC 7)
Max Uplift1 =· 113(LC 8), 7=·115(LC 8)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-17=·2219/282, 2-17=2115/307, 2-18=-1844/226, 3-18=·1770/243, 3-19=-1606/244, 19-20=·1610/243, 20-21=-1610/243, 4-21=·1613/243,
4-22=-1611 /239, 22-23=-1608/239, 5-23=-1604/239, 5-24= 1768/237, 6-24=-1841/219, 6-25=-2110/291, 7-25=-2214/265
BOT CHORD 1-10=·226/1967, 9-10= 119/1735, 8·9=-119/1735, 7-8=·207/1961
WEBS 2-10=456/149, 3-10=4/471, 4-10=-272/54, 5-8=·0/477, 6-8=454/134, 4-8=-273/55
NOTES
1) This truss has been checked for uniform roof live load only, excepl as noted.
2) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; l=26ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the·bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) A plate rating reduction of 20% has been applied for, the green lumber members.
7) Refer to girder(s) for truss to truss connections.
8) This truss is designed in accordance.with the 2012 International Building Code section 2306.1 and referenced standard ANSl(fPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
1 O) Girder carries tie-in spans of 2-0-0 from front girder and 2-0-0 from back girder.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 49 lb down and 18 lb up at 15-8-8, and 49 lb down and 18 lb
up at 10-1-0 on top chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25
Uniform Loads (pl!)
Vert: 1-3=68, 3-5=·68, 5-7=68, 11-14=-20
Concentrated Loads (lb)
Vert: 19=-34 23=-34
Job "
ENGINEERING
Truss
AC03
Truss Type
California
Qty Ply 24190-Bowling Residence-rnichaelc
Job Reference a tional
' California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 0212:38:17 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-AOdklaEt9RpBBMyFGk4tlGPTOOyWdQA8mwGGkjzAl5
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
4-10-2'
4-10-2
TOP CHORD 2x4 OF No.2 G
BOT CHORD 2x4 OF No.2 G
9-7-5
4-9-2
16:0-2-0 0-1-8
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
WEBS 2x4 OF Stud/STD G
11-6-11
1-11-6
13-0-4 14-5-13
12-o-i11 1
1
3-11-13 I 16-5-3
6-6-0 0-11-9' 1-11-6
0-11-9 0-6-0
21-2-6
4-9-2
25-6-0
4-3-10
2x4 JI 6 2x4 11
10
CSI
TC 0.52
BC 0.68
WB 0.23
(Matrix-M)
16-5-3 25-9-8
6-9-15 9-4-5
DEFL in (lac) I/dell Ud PLATES GRIP
Vert(LL) -0.1414-22 >999 360 MT20 220/195
Vert(TL) -0.4714-22 >662 240
Horz(TL) 0.10 13 n/a n/a
Wind(LL) 0.09 14-16 >999 240 Weight: 121 lb FT=20%
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-2-4 oc purlins, except
0-0-0 oc purlins (4-10-13 max.): 3-11. Except:
4-11-0 oc bracing: 5-8
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
Scale .. 141,
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 1=1160/0-5-8 (min. 0-1-8), 13=1138/Mechanical
Max Herz 1 =98(LC 9)
Max Uplift1=-113(LC 10), 13=-115(LC 10)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-23=-2160/358, 2-23=-2102/383, 2-24~ 1806/321, 3-24= 1735/341, 3-26=-1581/400, 5-26=-1581/400, 5-27 =-1582/402, 27-28=-1582/402,
7-28=-1582/402, 7-29=-1582/398, 8-29=-1582/398, 8-30=-1581/396, 11-30=-1581/396, 11-32=-1735/335, 12-32~ 1805/315, 12-33=-2102/367,
13-33=2160/342
BOT CHORD 1-16~295/1911, 15-16~270/1698, 14-15=-270/1698, 13-14=-276/1911
WEBS 2-16=·442/135, 3-16=·58/468, 7-16=-281/133, 11-14=-53/478, 12-14=-4421121, 7-14=-289/139, 4-5=-356/106
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=26ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left·and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcu\rent with any other live loads.
5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) A plate rating reduction of 20% has been applied for the green lumber members.
7) Refer to girder(s) for truss to truss connections.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job 'I
ENGINEERING
Truss
AC04
Truss Type
Common
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional • California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 Milek Industries, Inc. Thu Jun 02 12:38:17 2016 Page 1
ID:2Kw9I?x7pMrCN8?W4AMGRDzHVMu-AOdklaEt9RpBBMyFGk4tlGPNSOzQdPf8mwGGkjzAl5
6-9-10
6-9-10
13-0-4
6-2-10
19-2-14 25-6-0 25-~-8
6-2-10 6-3-2 Ql3-8
3'6=
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
8-10-8
8-10-8
SPACING 2-0-0
Plates increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
CSI
TC 0.94
BC 0.62
WB 0.26
(Matrix-M)
4x6=
17-2-0
8-3-9
DEFL in
Vert(LL) -0.17
Vert(TL) -0.42
Horz(TL) 0.08
Wind(LL) 0.09
BRACING
TOP CHORD
BOT CHORD
25-9-8
8-7-8
(loo) I/dell Ud PLATES GRIP
8-10 >999 360 MT20 220/195
8-10 >737 240
7 n/a n/a
8-10 >999 240 Weight: 102 lb FT=20%
Structural wood sheathing directly applied.
Rigid ceiling directly applied or 6-0-0 oc bracing.
Scale• 1·40
WEBS 2x4 DF Stud/STD G Milek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 1=1148/0-5-8 (min. 0-1-8), 7=1122/Mechanical
Max Herz 1=106(LC 26)
Max Uplift1 =0331 (LC 27), 7=·325(LC 28)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when s~own.
TOP CHORD 1-17=-2053/717, 2-17=1966/520, 2-3=1805/469, 3-18=-1716/357, 4-18=-1708/347, 4-19=-1716/326, 5-19=-1725/333, 5-6=-1814/445,
6-20=-1975/494, 7-20=-2062/691
BOT CHORD 1-21 =-326/1888, 10-21 ~622/1792, 10-22~500/1199, 9-22~500/1199, 9-23=-500/1199, 8-23=·500/1199, 7-8=-602/1803
WEBS 4-8~621671, 6-8=-425/175, 4-10=·48/663, 2-10~419/166
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25lt; 8=401!; L=26ft; eave=4lt; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cartilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 10.0psf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) Refer to girder(s) for truss to truss connections.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) This truss has been designed for a total drag load of 1000 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord
from 0-0-0 to 2-0-0 for 500".0 pit.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in ihe analysis and design of this truss.
LOAD CASE(S) Standard
Job "l
ENGINEERING
Truss
AC05
Truss Type
Common
Qly Ply 24190-Bowling Residence-michaelc
Job Reference o tional California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 Milek Industries, Inc. Thu Jun 02 12:38:18 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-eCB6yvEVwkx2oWXRpSc6ITxYBQJhMswH?aOpGAzAl5
6-7-10 12-10-4
6-7-10 6-2-10
19-0-14 25-4-0 29-1·
6-2-10 6-3-2 0-3-8
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
8-8-8
8-8-8
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
CSI
TC 0.94
BC 0.62
WB 0.26
(Matrix-M)
4X6=
17-0-0
8-3-9
DEFL in
Vert(LL) -0.17
Vert(TL) -0.41
Horz(TL) 0.08
Wind(LL) 0.06
BRACING
TOP CHORD
BOT CHORD
Scale•1:40
25-7-8
8-7-8
(loc) I/dell Ud PLATES GRIP
8-10 >999 360 MT20 220/195
8-10 >752 240
7 n/a n/a
10 >999 240 Weight: 102 lb FT=20%
Structural wood sheathing directly applied.
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/STD G Milek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 1=113.1/0-3-8 (min. 0-1-8), 7=1124/Mechanical
Max Horz 1=105(LC 9)
Max Uplift1=-95(LC 10), 7=-95(LC 10)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown,.
TOP CHORD 1-17=-2067/203, 2-17=-1981/225, 2-3=·1819/201, 3-18=-1730/218, 4-18=-1721/240, 4-19=-1721/240, 5-19=-1729/218, 5-6=-1819/200,
6-20=-1980/225, 7-20=-2067/202
BOT CHORD 1-10=130/1847, 10-21=-11/1204, 9-21~11/1204, 9-22=-11/1204, 8-22=-11/1204, 7-8=-130/1807
WEBS 4-8=-43/670, 6-8=426/165, 4-10=·44/672, 2-10=·426/166
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; l=26ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone;.cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOl.=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 10.0psf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) Refer to girder(s) for truss to truss connections.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis·and design of this truss.
LOAD CASE(S) Standard
Job 1J
ENGINEERING
Truss
AC06
Truss Type
Common
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570
6-7-10
6-7-10
Run:7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 0212:38:18 2016 Page 1 ID:ZKw9I?x7pMrCNB?W4AMGRDzHVMu-eCB6yvEVwkx2oWXRpSc6ITxYBQJhMswH?aOpGAzAl5
12-10-4
6-2-10
19-0-14 25-4-o 28-71-8
6-2-10 6-3-2 0-3-8
Scale•141.1
4x6=
5.50[12
~-
~,C~r,~~-----------~.,-----~~-i~1--~---~~~----------~~-i~/~'--~~~-------------~~~"C::,b~7
~ 10 21 9
3)(4 3x6
4>:6=
8-8-8
8-8-8
Plate Offsets rX.Yl: 17:0-0-0 0-0-6}
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1-.25
Rep Stress Iner YES
Code IBC2012/TPl2007
CSI
TC 0.94
BC 0.62
WB 0.26
(Matrix-M)
22
17-0-0
8-3-9
DEFL in
Vert(LL) -0.17
Vert(TL) -0.41
Horz(TL) 0.08
Wind(LL) 0.09
BRACING
TOP CHORD
BOT CHORD
""'
25-7-8
8-7-8
(lac) Vdefl Ud PLATES
8-10 >999 360 MT20
8-10 >752 240
7 n/a n/a
10 >999 240 Weight: 102 lb
Structural wood sheathing directly applied.
Rigid ceiling directly applied or 6-0-0 cc bracing.
GRIP
220/195
FT=20%
WEBS 2x4 DF Stud/STD G I MiTek recommends that Stabilizers and required cross bracing be installed during I
truss erection in accordance with Stabilizer Installation ouide.
REACTIONS (lb/size) 1=1131/0-3-8 (min. 0-1-8), 7=1124/7-2-0 (min. 0-1-8)
Max Herz 1=105(LC 9)
Max Uplift1=-447(LC 27), 7=,444(LC 28)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250·(Ib) or less except when shown.
TOP CHORD 1-17=-2067/971, 2-17=-1981/654, 2-3~1819/591, 3-18~1729/410, 4-18=-1721/399, 4-19=-1721/389, 5-19=-1729/398, 5-6=-1819/579,
6-20=-1980/641, 7-20=-2067/958
BOT CHORD 1-10=·868/1847, 10-21=·767/1427, 9-21~767/1427, 9-22~767/1427, 8-22=-767/1427, 8-23=-910/1807, 7-23=-781/1807
WEBS 4-8=-721670, 6-8=·426/179, 4-10=·66/672, 2-10=-426/175
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=26ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1 )-zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 1 O.Opsf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads. _
8) This truss has been designed for a total drag load of 1500 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord
from 18-5-8 to 25-7-8 for 209.3 plf.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job ,;
ENGINEERING
Truss
AC07
Truss Type
Common
Qty
2
Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek lndustrtes, Inc. Thu Jun 0212:38:19 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-6OIV9FF7h23vQf6dN97LqhUlrpeS5KEREEINoczAl5
27-4-8
6-7-10 12-10-4
6-7-10 6-2-10
19-0-14 25-7-0 25f1P,-8 I
6-2-10 6-6-2 0-3-8 1-6-0
9-6-10
9-6-10
Plate Offsets X 5:0-4-4 0-0-3
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 •
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
CSI
TC 0.81
BC 0.65
WB 0.25
(Matrjx-M)
4x6:::::
18-8-4
9-1-10
DEFL in
Vert(LI.:) -0.17
Vert(TL) -0.40
Horz(TL) 0.03
Wind(LL) 0.04
BRACING
TOP CHORD
BOT CHORD
WEBS
25-10-8
7-2-4
(loc) I/dell Ud PLATES GRIP
7-9 >999 360 MT20 220/195
9-12 >559 240
7 n/a n/a
9-12 >999 240 Weight: 106 lb FT=20%
Structural wood sheathing directly applied or 2-11-15 oc purlins.
Rigid ceiling directly applied or 6-0-0 oc bracing.
1 Row at midpt 3-7
Scale•143.
WEBS 2x4 DF Stud/STD G •Except•
W3: 2x4 DF No.2 G MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 1=785/0-3-8 (min. 0-1-8), 7=1244/0-5-8 (min. 0-1-8), 5=353/0-5-8 (min. 0-1-8)
Max Herz 1 =-119(LC 8)
Max Uplift1=-64(LC 10), 7=-105(LC 10), 5=-80(LC 10)
Max Grav1=785(LC 1), 7=1244(LC 1), 5=428(LC 31)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=-1373/139, 2-16=-1173/161, 2-17=-930/125, 3-17=-830/147, 3-18=0/254, 5-19=-870/0
BOT CHORD 1-9=-30/1860, 8-9=0/484, 8-20=0/484, 7-20=0/484, 5-7=0/1188
WEBS 2-9=-465/173, 3-9=-12/650, 3-7=-869/42, 4-7=-449/172
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-se_cond gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; l=26ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1 .33
3) This truss has been 'designed for.a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where·a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members, with BCDL = 10.0psf.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job '!
ENGINEERING
Truss
AC0B
Truss Type
DBL. FINK
Qty Ply 24190-Bowling Residence-michaelc
2 Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570
4-9-10
Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:20 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-abl!NbGISMBm2phpxteaNu1yhD3?qdCaSuVwl2zAl5
4-9-10
8-9-15
4-0-5
12-10-4
4-0-5
21-10-6 25-1-8 25-~-0
9-0-2 3-3-2 0!3_3
3x4=
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner NO
Code IBC2012/TPl2007
CSI
TC 0.62
BC 0.38
WB 0.85
(Matrix-M)
SxS-:::::-
4
21-10-6
11-5-2
14:0-2-4 0-1-8
DEFL in (loc) I/dell
Vert(LL) -0.0514-15 >999
Vert(TL) -0.1814-15 >999
Horz(TL) -0.02 9 n/a
Wind(LL) 0.08 14-15 >999
BRACING
Ud
360
240
n/a
240
11
GXS=
12
4XS=
10
2,4 ll
PLATES
MT20
Weight: 327 lb
25-5-0
3-6-10
GRIP
220/195
FT=20%
Scale•1:41.
2'4 II
9
4)1:fi=
TOP CHORD 2x6 DF No.2 G *Except*
T1: 2x4 DF No.2 G
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and
0-0-0 oc purlins (6-0-0 max.): 5-12, 5-8. Except:
BOT CHORD 2x6 DF No.2 G
WEBS 2x4 DF Stud/STD G *Except*
W5,W9: 2x4 DF No.2 G
REACTIONS All bearings 6-11-8 except Gt=length) 1=0-3-8.
(lb) -Max i-lorz 1=924(LC 20)
6-0-0 oc bracing: 5-8
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
Max Uplift All uplift 100 lb or less atjoint(s) except 1=-848(LC 25), 9=-1675(LC 22), 11=-2126(LC 25), 10=·134(LC 19)
Max Grav All reactions 250 lb or less atjoint(s) 10 except 1=2045(LC 22), 9=1059(LC 25), 11=6501(LC 13)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb} or less exceptwhen shown.
TOP CHORD 1-19=-2561/1015, 1-20=-3334/1613, 2-20=-3109/1343, 2-21 =-2836/1131, 3-21 =-2547/880, 3-22=-1145/464, 4-22=-838/191, 5-12=-2366/736,
4-5=-1696/609, 5-23=-702/729, 6-23=-1106/1100, 6-24=-1349/3524, 7-24=-1711/3886, 7-25=-454/445, 8-9=-596/95
BOT CHORD 1-15=-2293/3686, 14-15~2202/2823, 13-14=-2080/1996, 12-13=-2080/1996, 11-12~3483/1436, 10-11=-2938/2105, 9-10=-1824/1137
WEBS 2-15=-347/120, 3-15=-345/1809, 3-g=-1045/258, 4-14=-315/2067, 6-12=-1254/4436, 6-11=-4088/1004, 7-11=-3327/1548, 7-10=-267/212,
7-9~ 1563/2834
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-9-0 oc, 2x6 -2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 -2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) This truss has been checked for uniform roof live load only, except as noted.
4) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=25ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional); cantilever left and right-exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.0psf on the bottom chord·in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
8) A plate rating reduction of 20% has been applied for the green lumber members.
9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
10) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
11) This truss has been designed for a total drag load of 3000 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord
from 18-5-8to25-5-0for431.1 pl!.
12) Girder carries tie-in span(s): 10-0-0 from 0-0-0 to 13-0-0; 11-6-0 from 13-0-0 to 25-5-0
13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
15) This truss has large uplift reaction(s) from gravity load case(s). Proper connection is required to secure truss against upward movement at the bearings. Building
designer must provide for uplift reactions indicated.
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25
Uniform Loads (pl!)
Vert: 12-16=-190(F=-170), 9-12=·20, 1-4=-68, 5-8=-271(F=-203)
Job ~
ENGINEERING
Truss
AD01
Truss Type
HOWE
Qty Ply 24190-Bowling Residence-michaelc
2 Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 MiTek Industries, Inc. Thu Jun 0212:38:21 2016 Page 1 ID:ZKw9l?x7pMrCN8?W4AMGRDzHVMu-2nsFaxHNDfJdfzFOVa9pw6ZDAdPCZFKjhYETtVzAI5
-1-6-0 4-6-2 8-1-0
1-6-0 4-6-2 3-6-14
11-7-14 15-10-8 16·1~ro 17-8-0
3-6-14 4-2-10 0~3-8 1-6-0
II
I I
I
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL o.o •
BCDL 10.0
LUMBER
4-6-2 8-1-0
4-6-2 3-6-14
SPACING 2-0-0 CSI
Plates Increase 1.25 TC 0.25
Lumber Increase 1.25 BC 0.31
Rep Stress Iner NO WB 0.15
Code IBC2012/TPl2007 (Matrix-M)
I 11-7-14 16-2-0
3-6-14 4-6-2
DEFL in (Joe) I/dell LJd PLATES GRIP
Vert(LL) -0.03 9 >999 360 MT20 220/195
Vert(TL) -0.11 9 >999 240
Horz(TL) 0.04 6 n/a n/a
Wind(LL) 0.03 9 >999 240 Weight: 165 lb FT=20%
BRACING
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x6 DF No.2 G
TOP Cl:IORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/STD G
REACTIONS (lb/size) 2=1648/0-3-8 (min. 0-1-8), 6=1648/0-3-8 (min. 0-1-8)
Max Horz2=-77(LC 6)
Max Uplift2=-220(LC 8), 6=-220(LC 8)
Max Grav2=1759(LC 13), 6=1759(LC 14)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. .
TOP CHORD 2-15=-3459/358, 2-16=-3486/408, 3-16=-3452/421, 3-17=-3051/507, 4-17~3007/519, 4-18=-3007/519, 5-18=-3051/507, 5-19=-3452/421,
6-19=-3486/408,.6-20~3459/358
BOT CHORD 2-10=-287/3179, 9-10~287/3179, 8-9=·287/3145, 6-8=-287/3145
WEBS 3-10=0/286, 4-9=01729, 5-8=0/286, 3-9=-599/0, 5-9=-599/0
NOTES
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Bottom chards connected as follows: 2x6 -2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or: back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) This truss has been checked for uniform roof live load only, except as noted.
4) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6:0psf; h=25ft; B=40ft; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional); cantilever left and right exposed ; end v~rtical left and right exposed; Lumber DOL= 1.33 plate grip DOL= 1.33
5) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
7) A plate rating reduction of 20% has been applied.for the green lumber members.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
10) Girder carries hip end with 8-1-0 end setback.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
12) Hanger(s) or other connection device(s) shall l)e provided sufficient to support concentrated load(s) 1611'lb down and 479 lb up at 8-1-0 on top chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber lncrease=1,25, Plate lncrease=1.25
Uniform Loads (pl!)
Vert: 2-6=-48(F~28), 1-4=-68, 4-7=-68
Concentrated Loads (lb)
Vert: 4=-1206
Scale-1:30
Job ~
ENGINEERING
Truss
AD02
Truss Type
Common
Qty
3
Ply 24190-Bowling Res1dence-michaelc
Job Reference o t,onal California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 M1Tek Industries, Inc. Thu Jun 0212:38:21 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-2nsFaxHNDfJdfzFOVa9pw6ZAMdNCZFsjhYETtVzAl5
-1-6-0
1-6-0
4-3-12
4-3-12
8-1-0
3-9-4
11-10-4 15-10-8 1?-2r,0
3-9-4 4-0-4 0-3-8
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
8-1-0
8-1-0
CSI
TC 0.43
BC 0.44
WB 0.18
(Matrix-M)
4:WS=
DEFL in
Vert(LL) -0.05
Vert(TL) -0.18
Horz(TL) 0.03
Wind(LL) 0.0?
BRACING
TOP CHORD
BOT CHORD
16-2-0
8-1-0
(lac) I/dell Ud PLATES GRIP
7-11 >999 360 MT20 220/195
7-11 >999 240
6 n/a n/a
7 >999 240 Weight:64Ib FT=20%
Structural wood sheathing directly applied or 5-8-3 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
$cale• 1:27
WEBS 2x4 DF Stud/STD G MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 6=709/0-5-8 (min. 0-1-8), 2=820/0-5-8 (min. 0-1-8)
Max Horz2=78(LC 9)
Max Uplift6=-59{LC 10), 2=·119(LC 10)
FORCES (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-15=-1184/133, 3-:15=-1133/155, 3-16=-886/97, 4-16=-828/111, 4-17=-828/112, 5-17~887/98, 5-18~1140/159, 6-18=-1190/137
BOT CHORD 2-8=-89/1080, 7-8=-89/1032, 6-7=-94/1149
WEBS 4-7=-7/446, 5-7=-416/119, 3-7~12/113
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 O; Vult=11 Qmph {3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed; MWFRS {directional) and C-C lnterior(1) zone;
cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and.referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE{S) Standard
Truss
ENGINEERING AD03
Truss Type
DBL. HOWE
Qty Ply 24190-Bowling Residence-michaelc
2 Job Reference o tional
1 · California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:22 2016 Page 1 ID:ZKw9I?x7pMrCNB?W4AMGRDzHVMu-WzQdoHl?_zRUH7qC2Hg2SJ6Kj1 allVNtwC_ 1 PxzAl5
-1-6-0 3-3-14
1-6-0 3-3-14
5-8-7
2-4-9
8-1-0 10-5-9 12-10-2 15-10-8 1 ?·2r,0
2-4-9 2-4-9 2-4-9 3-0-6 0-3-8
4ll5=
16-2-0
3-3-14
13:0-3-4 0-1-8
LOADING (psf) SPACING 2-0-0 CSI PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.45
DEFL
Vert(LL)
Vert(TL)
Horz{TL)
Wind(LL)
in (lac)
-0.09 10
1/defl
>999
>648
Ud
360
240
n/a
240
MT20 220/195
TCDL 14.0
BCLL 0.0 •
BCDL 10.0
LUMBER
Lumber Increase 1.25
Rep Stress Iner NO
Code. lBC2012/TPl2007
BC 0.96
WB 1.00
(Matrix-M)
-0.30 10-11
0.09 8
0.08 10-11
n/a
>999 Weight: 179 lb FT= 20%
TOP CHORD 2x4 OF No.2 G
BOT CHORD 2x6 OF No.2 G
BRACING
TOP CHORD
BOT CHORD
Structural wood sheathing directly applied or 3-11-1 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF Stud/STD G
REACTIONS {lb/size) 2=3012/0-3-8 (min. 6-1-10), 8=4959/0-3-8 {min. 0-2-11)
Max Herz 2=84(LC 24)
Max Uplift2=-647(LC 25), 8=723{LC 26)
Max Grav2=3012(LC 1), 8=5054(LC 15)
FORCES {lb) -Max. CompJMax. Ten. -All forces 250 {lb) or less except when shown.
TOP CHORD 2-20=-6455/1276, 2-21=-6474/1218, 3-21=-6446/1092, 3-22=-6412/1012, 4-22=-6385/922, 4-23=-6197/801, 5-23=-6143/688, 5-24=-6142/678,
6-24=-6196/792, 6-25=7887/1047, 7'25=-7914/1.160, 7-26=-9675/1406, 8-26=-9701/1497, 8-27=-9769/1582
BOT CHORD 2-13=-1156/5859, 12-13=-1156/5859, 11-12=-1175/5806, 11-18=-1292/7173, 10-18=-1292/7173, 9-10=-1453/8814, 9-19=-1453/8814,
8-19=-1439/8814
WEBS 5-11 =-423/4906, 6-10= 172/2422, 7-9= 110/1601, 3-12=262/40, 4-11 =-335/47, 6-11 =-2427/226, 7-10=-2000/190
NOTES
1) 2-ply truss·to be connected togelher with 1 Od (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4-1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 -2 rows staggered at0-3-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (BJ face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (8), unless otherwis~ indicated.
3) This truss has been checked for uniform roof live load only, except as noted.
4) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=401!; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS {directional); cantilever left and right exposed ; end vertical left and right exposed; Lumtier DOL=1.33 plate grip DOL=1.33
5) This truss has been designed for a 10.0 psf bottom chord.live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where-a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
7) A plate rating reduction of 20% has been applied for the green lumber members.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
9) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
10) This truss has been designed for a total drag load of 1500 lb. Lumber DOL=(1.33) Plate grip DOL={1.33) Connect truss to resist drag loads along bottom chord
from 14-2-0 to 16-2-0 for750.0 plf.
11) Girder carries tie-in span{s): 25-9-8 from 9-0-0 to 16-2-0
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2737 lb·down and 230 lb up at 8-2-8 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others. ·
LOAD CASE(S) Standard
1) Dead + Roof Live {balanced): Lumber Increase= 1.25, Plate Increase= 1.25
Uniform Loads (pit)
Vert: 2-18=-20, 8-18=-537(F=-517), 1-5=-68, 5-8=-68
Concentrated Loads (lb)
Vert: 11 =-2737(F)
Scale•127.
Job -~,
ENGINEERING
Truss
AE01
Truss Type
Common Supported Gable
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o lional
"California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:23 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-?A_ ??dlelHZKvHPOc?BH?XeZBR8T1 BL09sjaxNzAl5
1 11-2-8 lsio 13-o-o I I -1-6-0
1-6-0
5-9-0
5-9-0 5-5-8 -3-8 1-6-0
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/l"Pl2007
CSI
TC 0.22 BC O.D7
WB 0.05
(Matrix)
3x4=
11-6-0
11-6-0
DEFL in
Vert(LL) 0.00
Vert(TL) -O.Q1
Horz(TL) 0.00
Wind(LL) o.oo
BRACING
TOP CHORD
BOT CHORD
(lac) I/dell Ud PLATES GRIP
10 n/r 180 MT20 220/195
11 n/r 120
10 n/a n/a
11 n/r 120 Weight: 51 lb FT=20%
Structural wood sheathing directly applied or 6-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 cc bracing.
Sca!e-1:229:
~I
OTHERS 2x4 DF Stud/STD G MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS All bearings 1-1-6-0.
(lb) -Max Herz 2=59(LC 9)
Max Uplift All uplift, 100 lb or less atjoint(s) 2, 10, 13, 16
Max Grav All reactions 250 lb or less atjoint(s) except 2=364(LC 27), 10=364(LC 35), 12=347(LC 34), 13=286(LC 33), 14=258(LC 32),
17=347(LC 28), 16=286(LC 29), 15=258(LC 22)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 9-12=-304/40, 8-13=-265/46, 3-17=-304/40, 4-16=-265/46
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft;-B=40ft; '-=24ft; eave=2ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional) and C-C lnterior(1) zone; cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL= 1.33 plate grip DOL= 1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exl)Osed to wind (normal to t_he face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members,
8) A plate rating reduction of 20% has been applied for the green lumber members.
9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
10) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job -~
ENGINEERING
Truss
AE02
Truss Type
Common Girder
Qty Ply 24190-Bowling Residence-michaelc
Job Reference a tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 02 12:38:23 2016 Page 1 ID:ZKw9l?x7pMrCN8?W4AMGRDzHVMu-?A_ ??dlelHZKvHPOc?BH?XeXzR?V1 6n09sjaxNzAl5
3-2-0 5-9-0
3-2-0 2-7-0
8-4-0 11-2-8 1~ -6-0
3>:S=
LOADING (psQ
TCLL 20.0
TCDL 14.0
BCLL 0.0 •
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
550[12
2»<\\
4-0-5
4-0-5
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner NO
Code IBC2012/TPl2007
3x4=
CSI
TC 0.36
BC 0.65
WB 0.35
(Matrix-M)
4).6=
B1
7-5-11
3-5-6
DEFL in
Vert(LL) -0.03
Vert(TL) -0.12
Horz(TL) 0.05
Wind(LL) 0.05
BRACING
TOP CHORD
BOT CHORD
18
3x4=
11-6-0
4-0-5
(lac) I/dell Ud PLATES GRIP
6'7 >999 360 MT20 220/195
6-7 >999 240
5 n/a n/a
6-7 >999 240 Weight: 45 lb FT= 20%
Structural wood sheathing directly applied or 3-9-1 oc purlins.
Rigid ceiling directly applied or 4-11-8 oc bracing.
Scale=117
WEBS 2x4 DF Stud/STD G MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
REACTIONS (lb/size) 1=1207/0-5-8 (min. 0-1-10), 5=1207/0-5-8 (min. 0-1-10)
Max Horz 1=46(LC 24)
Max Uplift1=-803(LC 25), 5=-803(LC 26)
Max Grav1=1553(LC 30), 5=1553(LC 29)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except :,vhen shown.
TOP CHORD 1-14=-2702/1573, 2-14=-2066/943, 2-15=-1905/795, 3-15=1755/495, 3-16=-1755/558, 4-16=-1936/932, 4-17=-2338/1208, 5-17=-2770/1640
BOT CHORD 1-7=1546/2608, 6-7=-1542/2:314, 6-1~1636/2672, 5-1~968/2672 -
WEBS 3-6=-95/852, 4-6=-271/77, 3-7=-137/852, 2-7=-271/110
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-10; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members,
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard-ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) This truss has been designed for a total drag load of 3000 lb. Lumber DOL=(1.33) Plate grip D0L=(1.33) Connect truss to resist drag loads along bottom chord
from 9-6-0 to 11-6-0 for 1500.0 plf.
9) Girder carries tie-in span(s): 8-0-0 from 0-0-0 to 11-6-0
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25
Uniform Loads (plQ
Vert: 1-3=-68, 3-5=-68, 8-11=-142(F=-122)
Job
ENGINEERING
Truss
AF01
Truss Type
Common Girder
Qty Ply 24190-Bowling Res,dence-michaelc
Job Reference o tional California TrusFrame LLC., Perris, CA. 92570
-1-6-0 3-2-0
1-6-0 3-2-0
5-9-0
2-7-0
Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 02 12:38:24 2016 Page 1
ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-TMYODzJGWahBWR_bAiiWXkBinqQ1mc3ANWT8UpzAl5DI
I 8-4-0 I 11-2-8 1 Hi0 13-0-0 I
2-7-0 2-10-8 0-3-8 1-6-0
Scala .. 1:229
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
4-0-5
4-0-5
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner NO
Code IBC2012/TPl2007
CSI
TC 0.35
BC 0.37
WB 0.15
(Matrix-Ml
7-5-11
3-5-6
DEFL in
Vert(LL) -0.03
Vert(TL) -0.09
Horz(TL) 0.03
Wind(LL) 0.03
11-6-0
4-0-5
(foe) I/dell Ud PLATES GRIP
8-9 >999 360 MT20 220/195
8-9 >999 240
6 n/a n/a
8-9 >999 240 Weight:50lb FT=20%
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
BRACING
TOP CHORD
BOT CHORD
Structural wood sheathing directly applied or 4-8-2 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/STD G
REACTIONS (lb/size) 2=984/0-5-8 (min. 0-1-8), 6=984/0-5-8 (min. 0-1-8)
Max Herz 2=-59(LC 6)
Max Uplifl2=·153(LC 8), 6=·153(LC 8)
Max Grav2=1007(LC 13), 6=1007(LC 14)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 2_50 (lb) or less except when shown.
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
TOP CHORD 2-16=-1670/218, 3-16=-1626/233, 3-17=1589/235, 4-17=1564/245, 4-18=-1564/245, 5-18=-1589/235, 5-19=-1626/233, 6-19=-1670/218
BOT CHORD 2-9=-131/1506, 9-20=-129/1319, 8-20=-129/1319, 6-8=-131/1480
WEBS 4-8=0/372, 4-9=0/372
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
2) Wind: ASCE 7-1 o; Vul1=110mph (3-second gust) Vasd=87mph; :J"CDL=8.4psf; BCDL=6.0psf; h=25ft; 8=4011; L=24ft; eave=4fl; Cat. II; Exp C; Kd 1.00; enclosed;
MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL:1.33
3) This truss has been designed for a 10.0 psi botto_m chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) Girder carries hip end with 5-9-0 end setback.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated'load(s) 740 lb down and 220 lb up at 5-9-0 on top chord. The
design/selection of such connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (BJ.
LOAD CASE(S) Standard
1) D~ad + Roof Live (balanced): Lumber lncrease=1.25, Plate lncrease=1.25
Uniform Loads (plf)
Vert: 1-4=-68, 4-7=68, 10-13=·36(F=-16)
Concentrated Loads (lb)
Vert:4=-554
Job ~ ·
ENGINEERING
Truss
AF02
Truss Type
Common
Qty Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570
-1-6-0
1-6-0
5-9-0
5-9-0
Run: 7.500 s Oct23 2013 Print: 7.500 s Oct23 2013 Milek Industries, Inc. Thu Jun 0212:38:25 2016 Page 1
ID:ZKw9I?x7pMrCNB?W4AMGRDzHVMu-xY6mQJKuHuq28aZnkQEl4ykqlEoHV4CJcAChOGzAl5
1
11-2-8 1 ~ -6-0 13-0-0
5-5-8 0-3-8 1-6-0
Scale-1:22.
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 •
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Iner YES
Code IBC2012/TPl2007
WEBS 2x4 DF Stud/STD G
5-9-0
5-9-0
REACTIONS (lb/size) 2=612/0-5-8 (min. 0-1-8), 4=612/0-5-8 (min. 0-1-8)
Max Rorz2=59(LC 9)
Max Uplift2~100(LC 10), 4=-100(LC 10)
CSI
TC 0.56
BC 0.24
WB 0.09
(Matrix-M)
FORCES (lb) -Max. CompJMax. Ten. -f\11 forces 250 (lb) or less except when shown.
TOP CHORD 2-13=-894/39, 3-13~600/57, 3-14~600/57, 4-14=-894/39
BOT CHORD 2-6=0/1148, 4-6=0/1148
NOTES
1) This truss has been checked for uniform roof live load only, except as noted.
4x6=
DEFL in
Vert(LL) -0.02
Vert(TL) -0.07
Horz(TL) 0.01
Wind(LL) 0-01
BRACING
TOP CHORD
BOT CHORD
11-6-0
5-9-0
(lac) I/dell Ud PLATES GRIP
6-12 >999 360 MT20 220/195
6-12 >999 240
4 n/a n/a
6-12 >999 240 Weight: 41 lb FT=20%
Structural wood sheathing directly applied or 6-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
Milek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
2) Wind: ASCE 7-10; Vult=110mph (3-secimd gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; B=40ft; L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed; MWFRS (directional) and C-C lnterior(1) zone;
cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psi bottom chord-live load nonconcurrent with any other livEr loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) A plate rating reduction of 20% has been applied for the green lumber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other live loads.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job ,
ENGINEERING
Truss
AF03
Truss Type
Common
Qty
3
Ply 24190-Bowling Residence-michaelc
Job Reference o tional
California TrusFrame LLC., Perris, CA. 92570 Run: 7.500 s Oct 23 2013 Print: 7.500 s Oct 23 2013 MiTek Industries, Inc. Thu Jun 0212:38:25 2016 Page 1 ID:ZKw9I?x7pMrCN8?W4AMGRDzHVMu-xY6mQJKuHuq28aZnkQEl4ykqEEo8V4AJcAChOGzAl5
LOADING (psi)
TCLL 20.0
TCDL 14.0
BCLL 0.0 *
BCDL 10.0
LUMBER
TOP CHORD 2x4 DF No.2 G
BOT CHORD 2x4 DF No.2 G
5-9-0
5-9-0
5-9-0
5-9-0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress-Iner YES
Code IBC2012/TPl2007
WEBS 2x4 DF Stud/STD G
REACTIONS (lb/size) 1=506/0-3-0 (min. 0-1-8), 3=506/0-5-8 (min. 0-1-8)
Max Herz 1 =46(LC 9)
Max Uplift1=-42(LC 10), $=-42(LC 10)
Max Grav1=526(LC 19), 3=526(LC 27)
CSI
TC 0.56
BC 0.25
WB 0.10
(Matrix-Ml
FORCES (lb) -Max. Comp/Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-11=-937/107, 2-11 =-609/68, 2-12=-609/68, 3-12=-937/107
BOT CHORD 1-4=-157/1217, 3-4=-157/1217
NOTES
1) This truss has been checked for uniform roof live l_oad only, except as noted.
DEFL in
Vert(LL) -0.02
Vert(TL) -0.07
Horz(TL) 0.01
Wind(LL) 0.01
BRACING
TOP CHORD
BOT CHORD
11-2-8 1&-6-p
5-5-8 -
Scalea1:18
11-6-0
5-9-0
(lac) I/dell Ud PLATES GRIP
4-10 >999 360 MT20 220/195
4-10 >999 240
3 n/a n/a
4-10 >999 240 Weight: 36 lb FT=20%
Structural wood sheathing directly applied or 6-0-0 cc purlins.
Rigid ceiling directly applied or 10-0-0 cc bracing.
MiTek recommends that Stabilizers and required cross bracing be installed during
truss erection in accordance with Stabilizer Installation uide.
2) Wind: ASCE 7-1 O; Vult=110mph (3-second gust) Vasd=87mph; TCDL=8.4psf; BCDL=6.0psf; h=25ft; 8=40ft;,L=24ft; eave=4ft; Cat. II; Exp C; Kd 1.00; enclosed; MWFRS (directional) and C-C lnterior(1) zone;
cantilever left and right exposed; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live lo<!d nonconcurrent with any other live loads. .
4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) A plate rating reduction of 20% has been applieq for the green l_umber members.
6) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
7) This truss has been designed for a moving concentrated load of 250.0lb live located at all mid panels and at all panel points along the Top Chord, nonconcurrent
with any other Ihle loads.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Tf
U)
U)
-=I"
~-
~D <t
'1 i'i ·I· 1,:
•N 0 <(
<(
c\l 0 <t <(
h
'.:~ ~! ~ ~\
',C') ,o <t <t
'C') 0 <(
<(
IC') ,o
<( <t
•Cf) 'er., ,0 10 <( <(
'<( <t
C')
'0 <(
<(
C')
0 <(
<(
·cw:,
0 <t <(
C')
,0 ·< <(
' 1' I, /I 11' i " .' ,' '
II I' ,, i ' ,, I• I i 11 I, !! I ,, ! ' "
l :: i: 1: ;; !
r E ;
Cl) ..... 0 01 <( <(
<( <1
-=I" ~ ~
0
0 .....
111
if1
I ' ' ' " I
I ! I ! I Ii ! ~ ! ' ,, U ' ,, 1 ii · t --., I -,,--7
I ! i! i' ; ,l 'I ' •. .. l I •I , • ,1 j '1 ,
i ,, <' ::,., I, ', 1'• 11 '1' '11 11 ..... j I) " I
I ii i! ~ I 1: 'I 1 ;1 !• ,, :!
I 'I ,: C') 11 l 'I :, ': ii
~
I 11 1·: N I I l '1' ii :: Ii! ' I N I I /I ·I ' I ' ' I I' li i !i I I ' I 'I ,, ' ! ' I 11 I I 'I :, ;I
I I ' I 11 'I ,, I I '1'1' I 1, ·I I i' : I ! l 1 , :1 ii ~ I I I J I, 1! ii
·,
4 11 it ,!I,
CX)
0 ,;( 'jt
,' I ft_L...11
~ 'If 1 -----~ ~ 1. • n __ ":.._J_f 1' "
a, o,
<I)
<(;
C>i 01· <t: <t'· I:
i
0> i,o
0 "T""
~· !~
......
II~
··<t
I,
1 le9 :, jig 11~ 11,0 11,0 111:g
,N ...... ,<(
:<
" '1
l1 ·
i!
" !I !!-Ii
C')
..... <t <t
-=I"
·~
,<(
,,
LO CO ..........
<( <t
<( <t
/
I •• V
,.
,I
I
-=I" 0 co <t
-=I" 0 •CO ,<(
-=I" 0 ,CO <t
-=I" ,o co <(
·-=i-,o ,CO :<
-=I" 0 .co
<(
-=I" :o ,co
<(
,-=i-0
:lal ,<(
''cw:, •N ..-1:_4===---'io ·:a:: a::
::~ i<t <{ I fi---
i==
ii . I-==' I :! 'i :, .· 11 : ••
1
11 ,, ' :, ,I
Ii -
. ,I ~ ~~==~~===,~ o ,, 1319" I' C 8'0" ~
;;_--'i---,,-~,, :: I JL~~=-=--.=-=~=~=-=_=_=~~1= N
ri, .·1
1
•11··.,J :·1 '
I/ '-.;i / I :1 11 1 I I !1 l!
~ I I I I r1 11 ~ I I I I i: 11
g 1: I II I I· 11 ii ii ii 1: ·1
11
r-J~ Ii _L--11 I _
1
L
1
,~_ .. _ ~ !1 , . " "
1
1 / Ii ii /i !: ii I I j_w~RK!Acj,_J fTsl,Acf II ~
-1 1 1 · 1
11 1 11 ~ 1 L1r~1~:=tj 1 :L~tJ "
/
/ / '
/I
I I,
!I
I I' i• ' .I ,I '
'I 1,, :I L-hrlk-rr1t17 IL~+==r1 ,=~-\ I ii. I Ii L L L-
ii_ II !I !Vii ,Ii! ii II I/ Ii II
II ,.. 11 11 1 II a 11 -~
I 1 1 II I '1i 11 ! I II I I
II I ,
" "' ~
/ f I f I ,J ~ ' TT ' ' < '
II I IC') C') C') 1111¥--'~-'--+----hl' I ~ , 0 o O I ..... ,LL LLU.
',, <( <( <(
" I I ''.. N
I !I
11 1I !I Ii ' I,
1:
~~()rESS/o~
~~-1,
'.. '.. ~1 " ' 3000# DRAG ACOB "-"-, ~ ~ 11 ~ I Ii
Ii
(!) I AC07 I ' ·. \I~ 1 Acoz /. . s·111,2" IT I ·r
11
0 I I . 111 11: !l II II il fl
8' 1"
ii II
il 1: i
8 I 1soo# DRAG__acos_ · , 11.. , 11 • 111 rr } n 11~?__1
11~ I I AC05 I / / ,!Pl 11 I! 1,: !! :i 11 . / I ' 1000# DRAG AC04 . 11~ 11 I ·.· ' · ,. I .. -II ,. ,,.-il""l"'~ 1-""""''lii : -·!-oil ,, Ii 11, I ' • -' I 11 !! 1: 1j i :· :J / :::tt:1: :· I! :i :;c.Q !'. ;(
: 11 ;;
11 1: 11 II !1 :1
I i ~C03 1/ '1{51, ,: 1, i; I /~ ~ ' AC02 . ' ,Lni1 Ii ,, ,,, '· ,o
,-I / --• ,t' I I I ' U) 1' / [; ,: 'I, ii~1i 11 j,' '/ 'l:i:t:
/: :1 1• r1i ! !/ :;· ·1° AG_Qj ~ ·, I, ' I·: " ,,00 -
I I! ' ' ' ., : ,IN I' . I ii I :, 1· ,, ' . ., ---·'C') '"'
, .--11 ;: j; ,'! ; I; ' Ii I :r (0 ~ ' 'I _, ;-
!I 111 , I~ , lliii ~
APPROVAL FOR GENERAL COMPLIANCE WITH
STRUCTURAL CONTRACT DOCUMENTS
\XI APPROVED Fabncatmn may proceed as shown.
0 APPROVED AS CORRECTED Fabrication may proceed based on correcl!ons indicated
D APPROVED AS CORRECTED Fabncation may proceed based on corrections indicated
RESUBMIT FILE COPY Correct submission to resubmit for record purposes only.
0 DISAPPROVED Resubmit for approval.
0 REVIEWED FOR INFORMATION Approval not reqwred Accepted for mfo. purposes only.
Aoproval 1s for general comohance with the structural contract documents only This approval assumes
no responsibility for dimension, quantities, and cond1t!ons that pertain to fabrication and installatron or
for processes and techniques of construct1on The Contractor 1s responsible for coordination of the
work of all trades and the performance of this work m a sale and satisfactory manner
BY: Evan Coles, P.E. DATE: 6/3/16
SIMPLY STRONG ENGINEERING INC.
I _I I
' ~---,1 .....
00
=,_i!!l ,,
25' 9 1/2"
cw:,' o: C <(
;!N :8
,<(
,'C\I 0 :C ,·<t
..... ij .... o ·o o c~ .~ w <(:: <( . <( . ··~ I ,===,== • . -
C • <t -
.
DIGITALLY SIGNED I 4020 30th Street, San Diego, CA 92104
IM#24190i i
11 ~OB NOTES: 11 i
111 CONFIRM LAYOUT: L PRIOR TO ROLLING TRUSSES
~ ALL DIMENSIONS AS FOLLOWS:
FT-IN·X/16THS(I.E. 3-6-9= 3'-6-9116")
~ JACK B.C. TO 1-PLY GIRDER:
3-16d"s Back Nail OPT (6' setback or less) \41 JACK TO MUL Tl-PLY GIRDER:
LJ LUS24 typ. U.O.N.
!5i TOE-NAIL JACK T.C.: ~ W/3-16d's@ INTERSECTION wrr.c. OF HIP TRUSS 61 2' JACKS: ~ BACK NAIL W/3-16d's U.O.N.
!7j SPRINKLERS:
t:J DO NOT ATTACH TO GIRDER
TRUSSES. IF 2" OR LARGER PIPE IS
USED PLEASE CONTACT
CALIFORNIA TRUSFRAME
PROJECT:
Bowling Residence
ROOF
TRUSSES
PROJECT LOCATION:
Carlsbad, CA
REVISIONS
Plot Date: 6-2-16
_3 _
_ 3_
_3 _
_ 3 _
_ 3 _
_ 3 _
_ 3
3 _
_ 3_
I
~
~
~
~.
I
)J -..O·
""
COAST GEOTECHNICAL
CONSUL TING ENGINEER:$ AND GEOLOGISTS
August 23> 2016
Mike Bowling
MB Builders
4(tl Soµth Las Posas Road
San Marco$" CA 92078.
Subject: NOTlCB OF FOOTlNG EXCAVA1lON OBSERVATION
Proposed Residence and Attached Garage '
Lot 2, CT 98-16
2792 James Drive
Carlsbad, .. California
References: Please refer to page J
1) The footing excavation$ for the proposed residence and garage have been observed by this
firm.
2)
3)
The continuous wall and coh;i:rpn pl;!.d footing excavations for the residence and: garage are
founded into compacted :fill deposits with an ~xpansio.n potential in the very low range ( see
Rough Grading Report).
The footing excavations. are approved by this firm provided all loose deposits are removed
from the b~.s·e.ofthe exci;vations:priorto pouringconctete. The.footing excavations were not
reviewed for compliance with sfiilQturai plans and location.
P.O. BOX.230163 * ENCINITAS, CALlFORNJA 92023 e,·(4~55?
Coast Geotechnical Au.gust 23, 2016
W.O. G-659416
Page2 of 4
4) Observi;ttion-and ptobing or the µtility _trench backfill within the building footprint suggests
the-Qackfill was adequately .compacted.
If you have any questions regarding this report, please-.contactour office. Reference to our Job No.
P-659416 will'help expedite atesporise to your inquiry.
Resp~ctfully submitted,
COAST GEOfECHNI
M$.'k Burwell, C.KG.
Engineering Geologist
·•
Coast Geotechnical
.REFERENCES
l) PRELIMINARY GEOTECHNICAL INVBSTIQATION
Proposed Five (5) Lot Subdivision
Porti0n of Lots 3 and 4t Map 2169
Carlsbad TracL98 .. 16
Buena Vista Way
Carlsbad, California
Prepared qy Coast Geoteclmlcal
Dated S.eptember 23, 1999
2) GEOTECHNICAL UPDATE LEITER
Preposed Five (5) Lot SU:bc:livisioh
Portion of Lots 3 an¢! 4, Map.2) 69
Carlsbad Tract :98.,. I 6
Buena Vista Way
Caxlsbad, California
Prepared by Coast Geotechnical
Dated March 12, 2001
J) ROUGH GRADING REPORT
Proposed Five (5) tot Subdivision
Portion of Lots J and 4, Map,2169
Carlsbad Tract 98-16
Buena Vista Way
Catlsb~d, California
Prepared 'qy Coast Geotech.nical
J anuacy 7, 4004
4) SUPPLEMENTAL GEOtECHNlCAL I.NVESTIGATION
Ptoposed Residence and Subterrane_an Ba$·ement
Lot 2, CT 9:8-16
2792 James Drive
:Carlsba4, California
Prepared by Coa.$t Geoteehnical
bated June 21, 2004
August 23, 2016
W.O. G-659416
Page3 of4
Coast Geotechnic~l
5) FOUNDATION PLAN REVIEW
·proposed Residence and Subterranean Basement
Lot2.; CT 98-16
2792 James D:rive
CGU:lsbad~ California
· Prepared by Coast Ge9te¢hniciil
Dated June 21, 2004
6} GEOTECHNICAL UPDATE REPORT
Proposed Residence and.Attached ·Garage
tot 2, CT 98-16
2792 James Drive
· Carlsbad, .. California
Prepared by Coast deotechnical
Dated May 23., 2016:
7) FOUNDATlON.PLANREV'.IEW.
Proposed Residence and Attached ~age
Lot 2, CT 98-16
2792. James Drive
·Carlsbad; California
Prepared by Coast GeoteGhnicaJ:
Dated June 21, 2016
8) GRADING PLAN REVIEW
Propdsed Residence and. Attached Garage
Lot 2, CT 98-16
2792 James Drive
Carlsbad, California
Ptepared by Coast Geotechnical
'bated June 21, 1016
9) ROUGH GR.A.DING REPORT
Proposed Residence and Attached Garage
Lot2., CT98:-16
2792 Jc:unes Drive
Ca,rlsbad, California,
Prepared by Coast Geotechnical
Dated August 2, 2016
August 23, 2016
W.O. G-659416
Page4 of4
June 21, ~016
Mike Bowling
MB Builders
· COAST GEOTECHNICAL
CONSULTING ENGINEERS AND GEOLOGISTS
403 South Las Posas Road
San Marcos, CA 92078
Subject: FOUNDATION PLAN REVIEW
Proposed Residence and Attached Garage
Lot 2, CT 98-16
2792 James Drive
Carlsbad, California·
References: Please see page 3
Dear Mr. Bowling:
As requested, we have reviewed the project foundation plans, Sheets S3. 0A and S3. OB and Detail
Sheets S2 and S4, dated May 27, 2016, prepared by Simply Strong Engineering, and observed that
they havt;,, in general, included the recommenqations presented in our Preliminary G~otechnical
Update Report, dated May 23, 2016.
COMMENTS
1) All fill should be placed under the observation and testing of a representative of the
Geotechnical Engineer, Additional recommendations will be necessary during the remedial
grading phase.
779 ACADEMY DRIVE • SOIANA BEACH, CALIFORNIA 92075
(858) 755-8622 • FAX (858) 755-9126
....----,------------------··-------··--------·--·-------·----
Coast Geotechnical June 21, 2016
W.O. P-659416
Page2
2) Footings should be founded the design depth below the lowermost adjacent grade at the time
of foundati_on construction. All footings should be observed by an Engineering Geologist
prior to placement of forms and steel.
LIMITATIONS
The findings and opinions presented herein have been made in accordance with generally accepted
professional principals in the fields of engineering geology and geotechnical engineering. No
warranty is expressed or implied.
If you have any questions regarding this report, please contact our office. Reference to our Job No·.
P-659416 will help expedite a response to your inquiry.
Respectfully submitted,
COAST GEOTECHNIC
f
Mark Burwell, C.E. G.
Engineering Geologist
2109
CERT!FJED
Coast Geotechnical
REFERENCES
1) PRELIMINARY.GEOTECHNICALINVESTIGATION
Proposed five (5) Lot Subdivision
Portion of Lots 3 and 4, Map 2169
Carlsbad Tract 98-16
Buena Vista Way
Carlsbad, California
Prepared by Coast Geotechnical
Dated September 23, 1999
2) GEOTECHNICAL UPDATE LETTER
Proposed Five (5) Lot Subdivision
Portion of Lots 3 and 4, Map 2169
Carlsbad Tract 98-16
Buena Vista Way
Carlsbad, California
Prepared by Coast Geotechnical
Dated March 12, 2001
3) ROUGH GRADING REPORT
Proposed Five (5) Lot Subdivision
Portion of Lots 3 and 4, Map 2169
Carlsbad Tract 98-16
Buena Vista Way
Carlsbad, California
Prepared by Coast Geotechnical
, January 7, 2004
4) SUPPLEMENTAL GEOTECHNICAL INVESTIGATION
Proposed Residence and Subterranean Basement
Lot 2, CT 98-16
2792 James Drive
Carlsbad, California
Prepared by Coast Geotechnical
Dated June 21, 2004
-----,----------~---------···· --
June 21, 2016
W.O. P-659416
Page3
Coast Geotechnical
5) · FOUNDATION PLAN REVIEW
Proposed Residence and Subterranean Basement
Lot 2, CT 98-16 .
2792 James Drive
Carlsbad, California
Prepared by Coast Geotechnical
Dated June 21, 2004
6) . GEOTECHNICAL UPDATE REPORT
Proposed Residence and Attached Garage
Lot 2, CT 98-16
2792 Jam.es Drive
Carlsbad, California
Prepared by Coast Geotechnical
Dated May 23, 2016
June 21, 2016
-W.O. P-659416
Page4
..
\
COAST GEOTECHNICAL
CONSULTING ENGINEERS AND GEOLOGISTS
May 23, 2016
Mike Bowling
MB Builders
403 South Las Posas Road
San Marcos, CA 92078
Subject: GEOTECHNICAL UPDATE REPORT
Proposed Residence and Attached Garage
Lot 2, CT 98-16
2792 James Drive
Carlsbad, California
References: Please see page 15
Dear Mr. Bowling:
RECEiVED
JUN O 7 2016
CITY OF CARLSBAD
BUILDING DIVISION
The referenced property has recently been sold. This report updates the referenced Geotechnical
Reports, foundation design parameters and addresses current seismic design parameters. In general,
the plans for a single family residence and attached garage are in general conformance with the
design concepts anticipated in the Preliminary Geotechnical Report and Rough Grading Report for
the subdivision. Site review suggests that no significant changes, from a geotechnical viewpoint,
have occurred since the completion of our Rough Grading Report, dated January 7, 2004.
If you have any questions, please do not hesitate to contact us at (858) 755-8622. This opportunity
to be of service is greatly appreciated.
Respectfully submitted,
COAST GEOTECHNICAL
Mark Burwell, C.E.G.
Engineering Geologist
Vithaya Singhanet, P .E.
Geotechnical Engineer
779 ACADEMY DRIVE* SOLANA BEACH, CALIFORNIA 92075
(858) 755-8622 * FAX (858) 755-9126
Coast Geotechnical
PROPOSED DEVELOPMENT
May23,2016
W.O. U-659416
Page2 of 16
Grading plans for the development of the site were prepared by Bill Yen & Associates. The project
includes the construction of a single family residence and attached garage near the existing pad
grade. A long concrete driveway which enters from James Drive will provide access to the flag lot.
Fills up to 0.5 feet are anticipated in the proposed residential pad.
GEOLOGIC CONDITIONS
The .subject property is located in the Coastal Plains Physiographic Province of San Diego. The
property is underlain at relatively shallow depths by Pleistocene terrace deposits. The terrace
deposits are mantled by approximately 3 .5 feet of compacted fill deposits which were placed during
rough grading in 2003 and2004. The fill is composed of slightly silty fine and medium-grained sand
with a potential expansion in the very low range.
Groundwater
No groundwater was observed to the depth of20 feet explored during our previous Supplemental
Geotechnical Investigation Report, dated June 21, 2004. However, it should be noted that seepage
problems can develop after completion of construction. These seepage problems most often result
from drainage alterations, landscaping and over-irrigation. In the event that seepage or saturated
ground does occur, it has been our experience that they are most effectively handled on an individual
basis.
Coast Geotechnical
Tectonic Setting
May 23, 2016
W.O. U-659416
Page 3 of 16
The site is located within the seismically active southern California region which is generally
characterized by northwest trending Quaternary-age fault zones. Several of these fault zones and
fault segments are classified as active by the California Division of Mines and Geology (Alquist-
Priolo Earthquake Fault Zoning Act).
Based on a review of published geologic maps, no known faults transverse the site. The nearest
active fault is the offshore Newport-Inglewood Fault Zone located approximately 5.4 miles west of
the site. It should be noted that the Rose Canyon Fault and Newport-Inglewood Fault are not a
continuous, well-defined feature but rather a zone of right stepping en echelon faults. The complex
series of faults has been referred to as the Offshore Zone of Deformation (Woodward-Clyde, 1979)
and is not fully understood. Several studies suggest that the Newport-Inglewood and the Rose
Canyon faults are a continuous zone of en echelon faults (Treiman, 1984). Further studies along the
complex offshore zone of faulting may indicate a potentially greater seismic risk than current data
suggests. Other faults which could affect the site .include the Coronado Bank, Elsinore, San Jacinto
and San Andreas Faults. The proximity of major faults to the site and site parameters are shown on
the enclosed Seismic Design Parameters.
Liquefaction Potential
Liquefaction is a process by which a sand mass loses its shearing strength completely and flows. The
temporary transformation of the material into a fluid mass is often associated with ground motion
resulting from an earthquake.
Coast Geotechnical May 23, 2016
W.O. U-659416
Page 4 of 16
Owing to the medium-dense nature of the Pleistocene terrace deposits and the anticipated depth to
groundwater, the potential for seismically induced liquefaction and soil instability is considered low.
CONCLUSIONS
1) The subject property is located in an area that is relatively free of potential geologic hazards
such as landsliding, high groundwater tables, liquefaction and seismically induced
subsidence.
2) The existing fill which was placed in 2003 and 2004 should be removed to a minimum depth
of 3.0 feet below existing grade and replaced as properly compacted fill for the support of
foundations, concrete flatwork and exterior improvements.
3) The proposed development should not adversely affect the adjacent properties provided the
recommendations of this report are implemented during the design and construction phases.
RECOMMENDATIONS
Removals/Recompaction
The existing fill deposits in the building pad should be removed and replaced as properly compacted
fill. Removals should extend a minimum of 5.0 feet beyond the building footprint. The depth of
removals are anticipated to be on the order of 3.0 feet. However, a minimum of 1.5 feet of fill
should underlie proposed footings. Most of the existing earth deposits are generally suitable for
Coast Geotechnical May 23, 2016
W.O. U-659416
Page 5 of 16
reuse, provided they are cleared of all vegetation, debris and thoroughly mixed. Prior to placement
of fill, the base of the removal should be observed by a representative of this firm. Additional
overexcavation and recommendations may be necessary at that time. The exposed bottom should
be sc.arified to a minimum depth of 6.0 inches, moistened as required and compacted to a minimum
of90 percent of the laboratory maximum dry density. Fill should be placed in 6.0 to 8.0 inch lifts,
moistened to approximately 1.0 -2.0 percent above optimum moisture content and compacted to a
minimum of 90 percent of the laboratory maximum dry density. Existing fill deposits in areas of
proposed concrete flatwork and driveways should be removed to an approximate depth of 12 inches
and replaced as properly compacted fill. Imported fill, if necessary, should consist of non-expansive
granular deposits approved by the geotechnical engineer.
Temporary Slopes/Excavation Characteristics
Temporary excavations should be trimmed to a gradient of 1: 1 (horizontal to vertical) over a 3 .5 foot
vertical or less depending upon conditions encountered during grading. Based on our experience in
the area, the Pleistocene terrace deposits are easily rippable with conventional medium to heavy earth
moving equipment in good working order.
Foundations
The following design parameters are based on footings founded into non-expansive approved
compacted fill deposits. Footings should not span cut/fill transitions. Footings for the proposed
structure should be a minimum of 12 inches and 15 inches wide and founded a minimum of 12
Coast Geotechnical May 23, 2016
W.O. U-659416
Page 6 of 16
inches and 18 inches below the lower most adjacent sub grade at the time of foundation construction
for single-story and two-story structures, respectively. A 12 inch by 12 inch grade beam or footing
should be placed across the garage opening. Footings should be reinforced with a minimum of four
No. 4 bars, two along the top of the footing and two along the base. Footing recommendations
provided herein are based upon underlying soil conditions and are not intended to be in lieu of the
project structural engineer's design.
For design purposes, an allowable bearing vaiue of 1700 pounds per square foot and 2000 pounds
per square foot may be used for foundations at the recommended footing depths for single and two
story structures, respectively.
For footings deeper than 18 inches, the bearing value may be increased by 250 pounds per square
foot for each additional 6.0 inches of embedment to a maximum of 3000 pounds per square foot.
The bearing value may be increased by one-third for short durations ofloading, which includes the
effects of wind and seismic forces.
The bearing value indicated above is for the total dead and frequently applied live loads. This value
may be increased by 33 percent for short durations of loading, including the effects of wind and
seismic forces.
Sulfate Content
Based on previous testing, the soluble sulfate content is negligible.
Coast Geotechnical
Slabs on Grade (Interior and Exterior)
May 23, 2016
W.O. U-659416
Page 7 of 16
Slabs on grade should be a minimum of 5.0 inches thick and reinforced in both directions with No.
3 bars placed 18 inches on center in both directions. Exterior slabs on grade should be a minimum
of 4.0 inches thick and reinforced with No. 3 placed 18 inches on center in both directions. The slab
should be underlain by a minimum 2.0-inch coarse sand blanket (S.E. greater than 30). Where
moisture sensitive floors are used, a J.11:inimum 10.0-mil Visqueen, Stego or equivalent moisture
barrier should be placed over the sand blanket and covered by an additional two inches of sand (S.E.
greater than 30). Utility trenches underlying the slab may be backfilled with on-site materials,
compacted to a minimum of 90 percent of the laboratory maximum dry density. Slabs including
exterior concrete flatwork should be reinforced as indicated above and provided with saw
cuts/expansion joints, as recommended by the project structural engineer. All slabs should be cast
over dense compacted subgrades. Exterior slabs should be provided with weakened plane joints at
frequent intervals in accordance with the American Concrete Institute (ACI) guidelines. Our
experience indicates that the use of reinforcement in slabs and foundations can reduce the potential
for drying and shrinkage cracking. However, some minor cracking is considered normal and should
be expected as the concrete cures. Moisture barriers can retard but not eliminate moisture vapor
movement from the underlying soils up through the slab.
Lateral Resistance
Resistance to lateral load may be provided by friction acting at the base of foundations and by
passive earth pressure. A coefficient of friction of0.30 may be used with dead-load forces. Design
Coast Geotechnical May 23, 2016
W.O. U-659416
Page 8 of 16
passive earth resistance may be calculated from a lateral pressure corresponding to an equivalent
fluid density of200 pounds per cubic foot with a maximum of 1200 pounds per square foot.
Retaining Walls
Cantilever walls (yielding) retaining nonexpansive granular soils may be designed for an active-
equivalent fluid pressure of 38 pounds per cubic foot for a level surcharge. Restrained walls
(nonyielding) should be designed for an "at-rest" equivalent fluid pressure of 60 pounds per cubic
foot. Wail footings should be designed in accordance with the foundation design recommendations.
All retaining walls should be provided with an adequate backdrainage system. A geocomposite
blanket drain such as Miradrain 6000 or equivalent is recommended behind walls. The soil
parameters assume a level nonexpansive select granular backfill compacted to a minimum of 90
percent of the laboratory maximum dry density.
Dynamic (Seismic) Lateral Earth Pressures
For proposed restrained walls (non-yielding), potential seismic loading should be considered. For
smooth rigid walls Wood (1973) expressed the dynamic thrust in the following form:
t.Pe = kh YH2 (non-yielding)
where kh is ½ peak ground acceleration equal to 50 percent of the design spectral response
acceleration coefficient (Sds) divided by 2.5 per C.B.C. (2007), Y is equal to the unit weight of
backfill and H is equal to the height of the wall.
Coast Geotechnical May 23,2016
W.O. U-659416
Page 9 of 16
The pressure diagram for this dynamic component can be approximated as an inverted trapezoid with
stress decreasing with depth. The point of application of the dynamic thrust is at a height of 0. 6
above the base of the wall. The magnitude of the resultant is :
ti.Pe = 19 .9 H2 (non-yielding)
This dynamic component should be added to the at-rest static pressure for seismic loading
conditions.
For cantilever walls (yielding), Seed and Whitman (1970) developed the dynamic thrust as:
ti.Pe = 3/8 kh YH2 (yielding)
The pressure diagram for this dynamic component can be approximated as an inverted trapezoid with
stress decreasing with depth and the resultant at a height of 0.6 above the base of the wall. The
magnitude of the resultant is:
ti.Pe = 7.4 H2 (yielding)
This dynamic component should be added to the static pressure for seismic loading conditions.
Settlement Characteristics
Estimated total and differential settlement over a horizontal distance of 30 feet is expected to be on
the order of 1.0 inch and 3/4 inch, respectively. It should also be noted that long term secondary
settlement due to irrigation and loads imposed by structures is anticipated to be 1/4 inch.
Coast Geotechnical
Seismic Considerations
May 23,2016
W.O. U-659416
Page 10 of 16
Although the likelihood of ground rupture on the site is remote, the property will be exposed to
moderate to high levels of ground motion resulting from the release of energy should an earthquake
occur along the numerous known and unknown faults in the region. The Newport-Inglewood
(offshore) Fault Zone located approximately 5.4 miles west of the property is the nearest known
active fault and is considered the design earthquake for the site.
Seismic Ground Motion Design Parameters
Seismic ground motion values were determined as part of this investigation in accordance with
Chapter 16, Section 1613 of the 2013 California Building Code (CBC) and ASCE 7-10 Standard
using the web-based United States Geological Survey (USGS) ground motion calculator. Generated
results including the Mapped (Ss, S1), Risk-Targeted Maximum Considered Earthquake (MCER)
adjusted for site Class effects (SMs, SM1) and Design (Sos, Sm) Spectral Acceleration Parameters as
well as Site Coefficients (Fa, Fv) for short periods (0.20 second) and I-second period, Site Class,
Design and Risk-Targeted Maximum Considered Earthquake (MCER) Response Spectrums, Mapped
Maximum Considered Geometric Mean (MCEo) Peak Ground Acceleration adjusted for Site Class
effects (PGAM) and Seismic Design Category based on Risk Category and the severity of the design
earthquake ground motion at the site are summarized in the enclosed Appendix A.
Coast Geotechnical
Site Class D
Seismic Design Category D
Ss:1.126
Sl:0.433
SMs: 1.182
SMl: 0.678
SDs: 0.788
SDI: 0.452
Fa: 1.049
Fv: 1.567
Preliminary Pavement Design
May 23, 2016
W.O. U-659416
Page 11 of 16
The following preliminary pavement section is recommended for proposed driveways:
4.0 inches of asphaltic concrete on
6.0 inches of select base (Class 2) on
12 inches of compacted subgrade soils or
5.5 inches of concrete on
12 inches of compacted subgrade soils
Subgrade soils should be compacted to the thickness indicated in the structural section and left in
a condition to receive base materials. Class 2 base materials should have a minimum R-value of 78
and a minimum sand equivalent of 30. Subgrade soils and base materials should be compacted to
a minimum of95 percent of their laboratory maximum dry density. Concrete should be reinforced
with No. 3 bars placed 18 ~nches on center in both directions.
Coast Geotechnical May 23, 2016
W.O. Uw659416
Page 12 of 16
The pavement section should be protected from water sources. Migration of water into subgrade
deposits and base materials could result in pavement failure.
Utility Trench
We recoll).lilend that all utilities be bedded in clean sand (S.E. greater than 30) to at least one foot
above the top of the conduit. The bedding should be moistened and tamped in place to fill all the
voids around the conduit. Imported or onwsite granular material compacted to at least 90 percent
relative compaction may be utilized for backfill above the bedding.
The invert of subsurface utility excavations paralleling footings should be located above the zone
of influence of these adjacent footings. This zone of influence is defined as the area below a 45
degree plane projected down from the nearest bottom edge of an adjacent footing. This can be
accomplished by either deepening the footing, raising the invert elevation of the utility, or moving
the utility or the footing away from one another.
Geotechnical Observations
Structural footing excavations should be observed by a representative of this firm, prior to the
placement of steel and forms. All fill should be placed while a representative of the geotechnical
engineer is present to observe and test.
Coast Geotechnical
Plan Review
May 23, 2016
W.O. U-659416
Page 13 of 16
A copy of the final plans should be reviewed by this office prior to the initiation of construction.
All of the recommendations in the Preliminary Geotechnical Report and supplemental reports which
are not superceded by this report remain applicable and should be implemented during the design
and construction phases.
LIMITATIONS
This report is presented with the provision that it is the responsibility of the owner or the owner's
representative to bring the information and recommendations given herein to the attention of the
project's architects and/or engineers so that they may be incorporated into plans.
If conditions encountered during construction appear to differ from those described in this report,
our office should be notified so that we may consider whether modifications are needed. No
responsibility for construction compliance with design concepts, specifications or recommendations
given in this r~port is assumed unless on-site review is performed during the course of construction.
The subsurface conditions, excavation characteristics and geologic structure described herein are
based on individual exploratory excavations made on the subject property. The subsurface
conditions, excavation characteristics and geologic structure discussed should in no way be
construed to reflect any variations which may occur among the exploratory excavations.
Coast Geotechnical May 23, 2016
W.O. U-659416
Page 14 of 16
Please note that fluctuations in the level of groundwater may occur due to variations in rainfall,
temperature and other factors not evident at the time measurements were made and reported herein.
Coast Geotechnical assumes no responsibility for variations which may occur across the site.
The conclusions and recommendations of this report apply as of the current date. In time, however,
changes can occur on a property whether caused by acts of man or nature on this or adjoining
properties. Additionally, changes in professional standards may be brought about by legislation or
the expansion of knowledge. Consequently, the conclusions and recommendations of this report
may be rendered wholly or partially invalid by events beyond our control. This report is therefore
subject to review and should not be relied upon after the passage of two years.
The professional judgments presented herein are founded partly on our assessment of the technical
data gathered, partly on our understanding of the proposed construction and partly on our general
experience in the geotechnical field. However, in no respect do we guarantee the outcome of the
project.
This study has been provided solely for the benefit of the client and is in no way intended to benefit
or extend any right or interest to any third party. This study is not to be used on other projects or
extensions to this project except by agreement in writing with Coast Geotechnical.
l
Enclosure: Seismic Design Summary (Appendix A)
Coast Geotechnical
REFERENCES
1) PRELIMINARY GEOTECHNICAL INVESTIGATION
Proposed Five (5) Lot Subdivision
Portion of Lots 3 and 4, Map 2169
Carlsbad Tract 98-16
Buena Vista Way
Carlsbad, California
Prepared by Coast Geotechnical
Dated September 23, 1999
2) GEOTECHNICAL UPDATE LETTER
Proposed Five (5) Lot Subdivision
Portion of Lots 3 and 4, Map 2169
Carlsbad Tract 98-16
Buena Vista Way
Carlsbad, California
Prepared by Coast Geotechnical
Dated March 12, 2001
3) ROUGH GRADING REPORT
Proposed Five (5) Lot Subdivision
Portion of Lots 3 and 4, Map 2169
Carlsbad Tract 98-16 ·
BuenaVista Way
Carlsbad, California
. Prepared by Coast Geotechnical
January 7, 2004
4) SUPPLEMENTAL GEOTECHNICAL INVESTIGATION
Proposed Residence and Subterranean Basement
Lot 2, CT 98-16
2792 James Drive
Carlsbad, California
Prepared by Coast Geotechnical
Dated June 21, 2004
May23,2016
W.O. U-659416
Page 15 of 16
Coast Geotechl).ical
5) FOUNDATION PLAN REVIEW
Proposed Residence and Subterranean Basement
Lot 2, CT 98-16
2792 James Drive
Carlsbad, California
Prepared by Coast Geotechnical
Dated June 21, 2004
May 23, 2016
W.O. U-659416
Page 16 of 16
ENCLOSURE
----,:;;r---··r--·---., ---r------r••' _..,T ___ ,. _ ... ,,_ .. _ .... ··-r:J"""'O"' •' __ ..,.._c--~-1::"""' .........,, ..,,-.a.u.a.......,.J•..t'.&&f-' • .....,.....,o/.__,
1 of2
EIJSGS Design Maps Summary Report
User-Specified :i:nput
Report Title BOWLING
Sun May 22, 2016 01:53:28 UTC
Building Code Reference Document ASCE 7-10 Standard
(which utlRzes USGS hazard data available in 2008)
Site Coordinates 33.1685°N, 117.3357°W
Site Soil Classification Site Class D -"Stiff Soil"
Risk Category I/II/III
USGS-Provided Output
1.126 g
0.433 g
SMS = 1.182g
SM1 = 0.678 g
Sos=
S01 =
0.788 g
0.452 g
For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum hortzontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
'a -II fll
MCE1t Response Spectrum
1.20
1.08
o.,G
0.84
0.72
O.GO
0.49
0.3G
0.24
0.12
0.00 -t-----1--+--+---+--+--+---f--+--+--i
0.00 0.20 0.40 O.GO 0.80 1.00 1.20 1.40 l.GO 1.80 2.00
Period, T (sec)
0.89
o.ao
0.72
0,64
o.s,
Design Response Spectrum
"& 0.411 ...
~ 0.40
0.32
0.24
0.16
0.09
0.00-1---1.----1--+--t--+--+---t--+--+---t
0.00 0.20 0.40 O.GO 0.90 1.00 1.20 1.40 l.GO 1.90 2.00
Period. T (sec)
For PGAM, TL/ Cp_5, and CR1 values, please yiew the deti'liled report.
5/21/2016 6:53 F
1 of6
lilJSGS Design Maps Detailed Report
ASCE 7-10 Standard (33.1685°N, 117.3357°W)
Site Class D -"Stiff Soil'~ Risk Category I/II/III
Section 11.4.1 -Mapped Acceleration Parameters
Note: Ground motion values provided below are for the direction of maximum horizontal
spectral response acceleration. They have been converted from corresponding geometric
mean ground motions computed by the USGS by applying factors of 1.1 (to obtain S5) and
1.3 (to obtain S1). Maps in the 2010 ASCE-7 Standarcl are provided for Site Class B.
Adjustments for other Site Classes are made, as needed, in Section 11.4.3.
From Figure 22-1 cii S5 = 1.126 g
-···------------------------.. ·----
From Figure 22-2 c21 S1 = 0.433 g
----·-···--··-··-·-----·---·----------------
Section 11.4.2 -Site Class
The authority having jurisdiction (not the USGS), site-specific geotechnical data, and/or the
default has classified the site as Site Class D, based on the site soil properties in
accordance with Chapter 20.
Table 20.3-1 Site Classification
Site Class -Vs
A. Hard Rock >5,000 ft/S -----"------N/A
N/A
N/A
N/A B. Rock
C. Very dense soil and soft rock
D. Stiff Soil
2,500 to 5,000 ft/s
1,200 to 2,500 ft/s
-·----·---··-------------
>50 >2,000 psf ·----------------------·-----------··-------
600 to 1,200 ft./s 15 to 50 1,000 to 2,000 psf -····-----·····--------···-. -. -----·-------·····-··--·-·--------·-----·-------------·····-·-·······--·--·-·
E. Soft. clay soil
F. Soils requiring site response
analysis In accordance with Section
21.1
<600 ft/s <15 <1,000 psf
Any profile with more than 10 ft of soil having the
characteristics:
• Plasticity Index Pl> 20,
• Moisture content w ~ 40%, and
• Undrained shear strength s0 < 500 psf ·--·----····--····----~----
See Section 20.3.1
For SI: lft/s = 0.3048 m/S 11b/ft2 = 0.0479 kN/m2
5/21/2016 6:59 I
. v1:u5u J.Y.IUj,I.:> .LJ..,ua.u'"'u. J......,'-'J;'V.1.1.-
2 of6
Section 11.4.3 -Site Coefficients and Risk-Targeted Maximum Considered Earthquake
(M,Cl;,a) Spectral Response Acceleration Parameters
Site Class
A
B
C
D
E
F
Site Class
A
B
C
D
E
F
Table 11.4-1: Site Coefficient Fa
Mapped MCE R Spectral Response Acceleration Parameter at Short Period
55 !':. 0.25 S5 = 0.50 55 = 0.75 Ss = 1.00
0.8 0.8 0.8 0.8
1.0 1.0 1.0 1.0
1.2 1.2 1.1 1.0
1.6 1.4 1.2 ( 1.1
2.5 1.7 1.2 0.9
See Section 11.4. 7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of S5
For Sb Cla~ = D and 5s = 1,126 g, Fa = 1,049
Table 11.4-2: Site Coefficient Fv
5s;?: 1.25
0.8
1.0
1.0
1.0
0.9
Mapped MCE R Spectral Response Acceleration Parameter at 1-s Period
S1 ~ 0.10 S1 = 0.20 S1 = 0.30 S1 = 0.40 S1 ~ 0.50
0.8 0.8 0.8 0.8 0.8
1.0 1.0 1.0 1.0 1.0
1.7 1.6 1.5 1.4 1.3
2.4 2.0 1.8 1.6 1.5
3.5 3.2 2.8 2.4 2.4
See Section 11.4.1 of ASCE 7
Note: Use straight-line interpolation for intermediate values of 51
For Ste Class = D and S1 = 0.433 g, fv = 1,567
5/21/2016 6:59 P
•c:s1gu 1vmp:s .uculucu .n.cpv1 l
3 of6
Equation {11.4-1): SMs = FaSs = 1.049 X 1.126 = 1.182 g
----·--· --------------~---
Equation (11.4-2): SM1 = F vS1 = 1.567 X 0.433 = 0.678 g
-------------
Section 11.4.4 -Design Spectral Acceleration Parameters
Equation (11.4-3): S05 = ¾ SMs = ¾ x 1.182 = 0.788 g
------· ·-----------------.. ·--------
Equation (11.4-4): S01 = ¾ SM1 = ¾ X 0.678 = 0.452 g
Section 11.4.5 -Design Response Spectrum
From Figure 22-12 C3l TL = 8 seconds
--------·--·-~·-··--. -·------------~---
Figure 11.4-1: Design Response Spectrum
S;:is= 0.788
T<T0 :S,. =Sm (0.4 + 0.6T /Ta)
Ta STS T5 : S1 =Sa,
T, <T:STL: s.=smJT
T>TL:S.=SniTL/F
S::,1 = 0.452 -,---------• -T ----------
To= 0.115 T5 = 0.574 1.000
Period, T (sec)
5/21/2016 6:591
,
1,;;:,,1b1l lV.1<1p:,, .LICL<tU,;;u 1,,;;pv• L J.J,1,1,t'·'' ,.,..,"t'_ "" .... lL 'l,,Ll.'1 ............ ~. TT .... ......,~·e,v "'I --va.i:::,-...u..o._t""..,,, ----· JI, -r.., .... -·ra.ar. ·-...... T ... _w_.
4of6
Section 11.4.6 -Risk-Targeted Maximum Considered Earthquake (MCEJ Response Spectrum
The MCER Response Spectrum is determined by multiplying the design response spectrum above by
1.5.
S11, = l.182
s .... l = 0 • 678 -1------" " " " -T " " -" ----"
T.; = 0.115 Ts= 0.574 . 1.000
Period, T (sec)
5/21/2016 6:59
5 of6
.1...1.""l:"•'' v'-.IJ:'-..,.,."'~,._..._......, •• ,. ... ,....,.t:i'"'.O ..... ,.. __ ..,..._::::t"_,.._r-· -· --r---r--r .. -----r-----
Section 11.8.3 -Additional Geotechnical Investigation Report Requirements for Seismic
Design Categories D through F
From Figure 22-z c4J PGA = 0.441
------------------------
Equation (11.8-1): PGAM = FpGAPGA = 1.059 x 0.441 = 0.467 g
------·------·-----r-------------------·-----------------------· ----------------------
Table 11.8-1: Site Coefficient FPGA
Site Class Mapped MCE Geometric Mean Peak Ground Acceleration, PGA
PGA S 0.10 PGA = 0.20 PGA = 0.30 PGA = 0.40 PGA 2: 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 I 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4. 7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of PGA
For Site Class = D and PGA = 0,441 g, FPGA = 1,059
Section 21.2.1.1 -Method 1 (from Chapter 21 -Site-Specific Ground Motion Procedures for
Seismic Design)
From Fig1.1re 22-11 csi CRS = 0.954
------------------· ··--·----------·---------
From Figure 22-18 C6l CR1 = 1.005
---.. -----·--------------------------·----_________ ,, _________ ,, _________ , _______ ., __
5/21/2016 6:591
5 of6
Section_ 11.6 -Seismic Design Category
Table 11.6-1 Seismic Design category Based on Short Period Response Acceleration Parameter
RISK CATEGORY
VALUE OF SDs
I or II III IV
S05 < 0.167g A A A
0.167g S S05 < 0.33g 8 B C
0.33g S S05 < 0.S0g C C D
0.50g S S 05 D D D
For Risk Category = I and Sos = 0.788 g, Seismic Design Category = D
Table 11.6-2 Seismic Design category Based on 1-S Period Response Acceleration Parameter
RISK CATEGORY
VALUE OF SD1 I or II III IV
S01 < 0.067g A A A
0.067g S S01 < 0.133g B 8 C
0.133g s SD1 < 0.20g C C D
0.20g S S01 D D D
For Risk Category = I and S.,1 = 0.452 g, Seismic Design Category = D
Note: When s1 is greater than or equal to 0. 75g, the Seismic Design Category is E for
buildings in Risk Categories I, II, and III, and F for those in Risk Category IV, irrespective
of the above.
Seismic Design Category = "the more severe design category in accordance with
Table 11.6-1 or 11.6-2" = D
Note: See Section 11.6 for alternative approaches to calculating Seismic Design Category.
References
1. Figure 22-1: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010__,ASCE-7 _Figure_22-1. pdf
2. Figure 22-2: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010__,ASCE-7 _Figure_22-2. pdf
3. Figure 22-12: http ://earthquake. usgs. gov /hazards/designmaps/downloads/pdfs/2010__,ASCE-
7 _Figure_22-12. pdf
4. Figure 22-7: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7 _Figure_22-7.pdf
5. Figure 22-17: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-
7 _Figure_22-17. pdf
6. Figure 22-18: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-
7 _Figure_22-18. pdf
5/21/2016 6:59 P
'1-1
BUILDING EN-ERGV ANALYSIS REPORT
PROJECT:
RECE&,!ED
JUN O 7 2016
CITY OF CARLSBAD
Proposed New Residence for Kim & Mike BowliBJllLDING OlViSION
2792 James Drive
Calrsbad, CA 92008
PROJECT DESIGNER:
ARoper Residential Design
1443 Panorama Ridge Road
Oceanside, CA 92056
760-522-3997
REPORT PREPARED BY:
David A Trimm
Title 24's by Larry
4401 W Judy Ave
Visalia, CA 93277-3926
559-625-8610
JOB NUMBER:
20165607-Bowling
Date:
05-20-2016
Y;
TABLE OF CONTENTS
Cover
Table of Contents
Form CF-lR-PRF-01 Certificate of Compliance
Form MF-1R Mandatory Measures Summary
1
2
3
12
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Page 1 of 9 Project Name: 20165607-Bowling
Calculation Description: Proposed New Residence
GENERAL INFORMATION
01 Project Name 20165607-Bowfing
02 Calculation Description 2974sqft Home
03 Project Location 2792 James Drive
04 City Carlsbad
06 Zip Code 92006
08 c·nmate Zone CZ?
10 Building Type Single Family
12 Project Scope Newly Constructed
14 Total Cond. Floor Area (ft2) 2974
16 Slab Area (92) 2974
18 Addition Cond. Floor Area N/A
20 Addition Slab Are~' (ft~): N/A
COMPLIANCE RESULTS .... , .... ., -,,,·v•__,,,,,..,
01
02
'· y-.•
04 05
Energy Use (kTDV/ft2-yr) Standard Design
Space Heating 3.57
Space Cooling 0.35
IAQ Ventilation 6.03
Water Heating 9.74
Photovoltaic Offset ----
Compliance Energy Total 19.69
Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd
... .. . .
..
05 Standards Version Compliance 2015
..
07 Compliance Manager Version BEMCmpMgr 2013-4 (744)
09 Software Version CBECC-Res 2013-4 (744)
11 Front Orientation (deg/Cardinal) 135
13 Number· of Dwelling Units 1
15 Number of Zones 2
17 Number of Stories 1
19 Natural Gas Available Yes
21 Glazing Percentage (%) 23.4%
-~
_ . fih~ s~per~isi~n of; CEC-appr~~ed HERS provider.
j•; ~,, .••• ,,.,,
~~· -~~ ....,,..#W'
ENERGY USE SUMMARY
06 07 08
Proposed Design Compliance Margin Percent Improvement
3.88 -0.31 -8.7%
2.11 -1.76 -502.9%
6.03 0.00 0.0%
7.13 2.61 26.8%
0.00 0.00 ----
19.15 0.54 2.7%
Registration Number: 216-N0188764A-OOOOOOOOO-OOOO Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
,,
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 20165607-Bowling Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd
CF1 R-PRF-01
Page 2 of 9
Calculation Description: Proposed New Residence
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition· for meeting the modeled energy performance for th.is computer analysis.
. ..
. '" NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
The following is a summary of the features that' must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing f, Domestic Hot Water System Verifications: .'
• --None ---t
i':, ...
ENERGY DESIGN RATING ,. ,, __ ... ,....-
This is the sum of the annual TDV energy.;9onsumption for en~rgy'.usi;9P.,mponentslinclu~~g iQJll_e peJ1.P,rrrianpg_cpmRJJince apprpach for the Standard Design Building (Energy'1fudget) anci the annual
TDV_ energy consumption for lighting and corriponen~_~n~_!JregulateJt,PY"'fitl~4~-t P~~t R~(fucn ~~:..aoln~itic)~pli'aii'c!~t[_aha consurp'er,~~.rtronic;.§) and accounting for the annual TDV energy offset by an
on-site renewable energy system. ; . ,' ,/ './..... ff ~:;,:,:1i LJ ff 1·:iZ;;;l ,:::;;:;:} :1 ~'"""· ~} (~"\1' tC~ ,. ___ . _____ -~----~ _____ f.:,_'L ~-t » ,~,-j Lt,,,~ t. *--~ \. l ~ ~ vi 111 't 1:~ ''"'•
,,_, , Refe?~ett4} Y~e~;:t:l ;,~,:~.' · :Y --~~~f~y ~e--~1pp'.'.R~!!~11i'.:. ·. Margin Percent Improvement
Total Energy (kTDV/f2-yr)* f;, .. 6~.19E: H;'t =---···--·''1 :62:6:°5::. 0.54 0.9%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING -FEATURES INFORMATION
01 02 03 04 os· 06 07
Number of Dwelling Number of Ventilation 'Number of Water
Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems
20165607-Bowling 2974 1 3 2 0 2
ZONE INFORMATION
01 02 03 04 05 06 07 ..
Zone Floor Area Avg. Ceiling
Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2
AC1 Bedrooms (heat/cool) Conditioned AC1 Bedrooms 1682 10 DHW System
AC2 Living (heat/cool) Conditioned AC2 Living 1292 10
Registration Number: 216-N0188764A-000000000-0000 Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Page 3 of 9 Project Name: 20165607-Bowling Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd Calculation Description: Proposed New Residence
OPAQUE SURFACES
ATTIC
01
Name
AC1 Front Wall
AC1 Left Wall
AC1 Back Wall
AC1 Right Wall
AC1-Garage Wall
AC1 Ceiling
AC2 Front Wall
AC2 Left Wall
AC2BackWall
AC2 Right Wall
AC2-Garage Wall
AC2Ceiling
Garage Front Wall
Garage Left Wall
Garage Back Wall
Garage Right Wall
Garage Ceiling
01
Name
AC1 Bedrooms Attic
AC2 Living Attic
Garage Attic
02 -03 04 05 06 07 08
Zone Construction Azimuth Orientation I Gross Area (ft2) I Wi~dow & Door Area (ft2) I Tilt (deg)
AC1 Bedrooms (heat/cool) EXTWALL 135 Front I 311.667 I 104.95 I 90
AC1 Bedrooms (heat/cool) EXTWALL 225 Left 783.333 80.25 90
AC1 Bedrooms (heat/cool) EXTWALL 315 Back 374.167 114 90
AC1 Bedrooms (heat/cool) EXTWALL 45 Right 327.5 67.25 90
AC1 Bedrooms (heat/cool)»Garage INTWALL 219.167 24
AC1 Bedrooms (heat/cool) CLGBLWATC 1682
AC2 Living (heat/cool) EXTWALL 135 Front 165.833 19.25 90
AC2 Li'ying (heat/cool) EXTWALL 225 Left 201.667 32.1 90
AC2, ~iyl~g (heat/cool) EXTWALL 315 Back 223.333 136 90
AC2J'..ivi,hg (heat/cool) EXTWALL 45 Right 373.333 142.5 90
··\ ... !"-f?2 Lfving (heat76oof)'>>~lt~~ge_, _:.i,;,,,~-" INTWALL 185 0
""'s.::_Pf?2 L~~ing)h~~flcojl)~ _I . R PJ½'i?.~~'CJ.At.Cr,~illi!ia,l~~ 1292
• 1 /Garage J HG-Exf;w~1.1. ~~~21 n-FF.mtiti 220 136 90 .., .. , ,,,," '\.\ :r,_ ~ 'It''} rt'('-...'"""~ !f::.;;.~/'~ f.,"lJ: ••J ~~
•Sara~gl 1fl \~cl;~'JM'Abl n (J f.Left\! 190 19.25 90 ~ -'~~~:,.. :~ -~ ,,.;,,,.~ ~ ~,l ¼~ ~~
Garag~\ ~ C::~EXTWAB~ ~ ~ BacR 100 0 90 '¾f'-.:3____ fjn({ ~---_,_r_~_ ~--M. __
Garage ,. "' ,.,·T· ,.,.,~ G'.'.EXTWALL -" r-. ·,is • r-Right ~ f' 474.167 I 24 I 90
Garage I G-CLGBLWATC I I I 951
02 03 04 05 06 07 08
Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
ATTICRF Ventilated 5.5 0.1 0.85 Yes No
ATTICRF Ventilated 5.5 0.1 0.85 Yes No
ATTICRF Ventilated 5.5 0.1 0.85 Yes No
Registration Number: 216-N0188764A-ooooooooo-oooo Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 20165607-Bowling Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd Calculation Description: Proposed New Residence
WINDOWS
01
Name
W021280
W03 3680 FrDr
W041280
W05 3656
Wo73656
W08 3656
W09 2616
W10 2650
W11 2616
W16 3616
W17 3056
W183056
W19 4056
W126080 GSD
W204056
W21 4056
W22 4056
W06 3656
W23 6080 GSD
W273656
W13 3616
W143616
W15 2880 FrDr
W2417080
PanoramicDr
W2813080
PanoramicDr
W25 3656
W26 3656
W01 3656
02 ·03
Type Surface (Orientation-Azimuth)
Window AC1 Front Wall (Front-135)
Window AC1 Front Wall (Front-135)
Window AC1 Front Wall (Front-135)
Window AC1 Front Wall (Front-135)
Window AC1 Front Wall (Front-135)
Window AC1 Front Wall (Front-135)
Window AC1 Left Wall.(Left-225)
Window ,!.
! :'
AC1 Left Wall (Left-225)
04 05 06
Multipli
Width (ft) I Height (ft) I er
1.2 I 8.0 I 1
3.5 8.0
1.2 8.0
3.5 5.5
3.5 5.5
-3.5 5:5
2.5 1.5
2.5 5.0
oi
Area
(ft~)
9.6
28.0
9.6
19.3
19.3
19.3
3.8
12.5
; Window ;1,~, AC1 Left Wall (Left-225) 2.5 1.5 3.8
Window I ,, : AC1 Left Wall (Left-225) 3.5 1.5 5.3
Window --.. -r, ' . .'! ·~ ' ' ~-..... -: .-, ACt:f~~-w_~Jl,:(J..eft,225) 3.0 5.5 16.5 ..... i,_
Window
Window
··c_: J-· .. , ...... ···· <i.\C1" Left~all (Left .... -225) .,C"'"'-~;--.· ;';·•,I,,,_ "'.'3:.0"1 .1"'fj;,...,., 5.5 !f'I 1 I 16.5 _, 'le -~ •• ~~.,.~ ,f..,.r·,-""'Mfl. ___ fi' t / ,:.P"'"'--1 ¥.t""'~ Lfe' ~, ;,,.J,,,,~"\w."~·-E-·,.ir ~-__ ________;_;_,
---::-:;-:1:, . Ac1 M~ftwa1it'{E~1t-22sjf Ff.ii tJ;l~J. -4'lG) '41"'"' s.5 1::;1 r.fi-;::-1 1IF22.o _,.... ;, t ~----.w:tt•,,l) '*° ·---'~ ____ _L__L 1:'-"".a~--ru --~--~-___ U_:c-::~----~
Window J.1:1/:;>'~. i... t:.;1;AC1s~.a"ck, .. ~wa11)1Baf.k!315f~:: ..... ""' .•. ri;,_.itt In ~i9 -Ill. ,.a.· !O f;.l· t.;i 1 JJ ,,~-.. !!. 8.:o J ' . ., J¥ ,:--.-~\-,~ _ .. ,,~~·1 ~'.:.\\".:__~ ,;;,~ ~-,~~ -~:,...:,.-~_l~ ~ -·--·. ,,,.,, ,:r;:~ __ ¥ t,J -if ~~~ ~
Window .. <',IC:-/ ---. ½,"-1:f\c_ .. _1··· B. ac;~w.-a.1_1_ ~B. ack•31'P __ )_···st."' ~ l~-'1:Q~. '41. -/j-~;u5!5 ll\""11/t >1-.... -10-..... 22.0 -'~ --_______S~ -. ------1.L~ -;.V...,,.., f~ ... --.~\ ~ ~~~ ij Jff \ 11,1 ~ M" ~~ . ,~,:.
Window AC1 Back Wall (Back-315) --,·· --r -~ 4.0 r -5:5 .... T ·r" I "'22:0
Window AC1 Back Wall (Back-315) 4.0 5.5 1 22.0
Window AC1 Right Wall (Right-45) 3.5 5.5 1 19.3
Window AC1 Right Wall (Right-45) 6.0 8.0 1 48.0
Window AC2 Front Wall (Front-135) 3.5 5.5 1 19.3
Window AC2 Left Wall (Left-225) 3.5 1.5 1 5.3
Window AC2 Left Wall (Left-225) 3.5 1.5 1 5.3
Window AC2 Left Wall (Left-225) 2.7 8.0 1 21.6 --
Window AC2 Back Wall (Back-315) 17.0 8.0 1 136.0
Window AC2 Right Wall {Right-45) 13.0 8.0 1 104.0
Window AC2 Right Wall (Right-45) 3.5 5.5 1 19.3
Window AC2 Right Wall (Right-45) 3.5 5.5 1 19.3
Window Garage Left Wall (Left-225) 3.5 5.5 1 19.3
Registration Number: 216-N0188764A-000000000-0000 Registration Date/Time: 2016-05-20 15:39:23
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744
:oa 09
U-factor SHGC
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0,35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
·o.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.35 0.35
0.40 I 0.40
0.40 I 0.40
0.35 0.35
0.35 0.35
0.35 0.35
HERS Provider:
I
I
CF1 R-PRF-01
Page 4 of 9
10
Exterior Shading
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
Insect Screen (default) --
Insect Screen (default)
Insect Screen (default)
---Insect Screen (default)
Insect Screen (default)
Insect Screen (default)
CalCERTS inc.
Report Generated at: 2016-05-20 12:49:21
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Page 5 of 9 Project Name: 20165607-Bowling
Calculation Description: Proposed New Residence
DOORS
" 01
Name
D03 3080 SC
D01 17080 GarageDr
D02 3080 GarageDr
OPAQUE SURFACE CONSTRUCTIONS
01 02 03
Construction Name Surface Type 1._ Construction Type
EXTWALL {_ ;\
Exterior wa9s! ,I\ Wood Framed Wall
~--,,....,~·,: .. ,~ ...
Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd
02 ...
Side of Building
AC1-Garage Wall
Garage Front Wall
Garage Right Wall
04
Framing
2x6 @ 16 in. O.C.
. '
"
05'
Total Cavity
R-value
R 19
. ' .,
''
06
Winter Design
U-value
0.072
03 04
-A~ea (fl2) U-factor
24.0 0.50
136.0 1.00
24.0 1.00
07
Assembly Layers
• Inside Finish:·Gypsum Board
Cavity I Frame: R-19 I 2x6
• Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board , •. .. ,,···:.::k ·:;..s~,:-r· ~-• Cavity/Frame: R-19/2x6
lnterior~Wc/,IIS ,..W9.od·Frani~d~all 0.067 • Other Side Finish: Gypsum-Board INTWALL ,_,. -~-,_, #':.I"'
CLGBLWATC
. . tJ /·<.·: "-~'>\ ff ,;~'i7 r • lnsi~e Finish: Gypsum Board
Ceilings (~el~w' < ?c--, \ \ ~-({:} {~"""".--: • Cavity I Frame: R-9. 1 I 2x4 Btm Chrd
attic),·"·___ · '-:.y,Jqo.,d Framed·e&ilih!l,.." •,o:ef2' • Over Floor Joists: R-20.9 insul.
G-EXTWALL
~,,_;, -~ m. ~ ~~~ m-"' -· ii! '/lf'Ji, ·-· lw Iii -r~ 1'"'
Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. none 0.347
• Inside Finish: Gypsum Board
• Cavity I Frame: no insu/. I 2x6
• Exterior Finish: 3 Coat Stucco
Ceilings (below 2x4 Bottom Chord of Truss @ 24 • Inside Finish: Gypsum Board
G-CLGBLWATC attic) Wood Framed Ceiling in.O.C. I none I 0.481 • Cavity I Frame: no insul. I 2x4 Btm Chrd
• Cavity I Frame: no insul. I 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking
ATTICRF Attic Roofs I Built-up Roof I in.O.C. I none I 0.644 • Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2) Perimeter (ft) Edge lnsul. R-value & Depth Carpeted Fraction Heated
AC1 Slab AC1 Bedrooms (heat/cool) 1682 179.667 None 0.8 No
AC2 Slab AC2 Living (heat/cool) 1292 96.4167 None 0.8 No
Garage Slab Garage 951 98.4167 None 0 No
Registration Number: 216-N0188764A-ooooooooo-oooo Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 20165607-Bowling
Calculation Description: Proposed New Residence
BUILDING ENVELOPE· HERS VERIFICATION
01
Quality Insulation Installation (Clli)
Not Required
WATER HEATING SYSTEMS
01 02
...
02
Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd
03
Quality Installation of Spray Foam Insulation Building Envelope Air Leakage
Not Required Not Required
03 04
•-,,-
..
05
Name System Type Distribution Type Water Heater Number of Heaters
OHW System -· 1/1 OHW Standard OWH1 1
OHW System -2/1 OHW Standard OWH2 1
WATER HEATERS 1\ '·" 01 o;i :\ 03 04 05 06 07
04
CFM50
---
CF1 R-PRF-01
Page 6 of 9
,,..
06
Solar Fraction (%)
-none -
-none -
~--r 08
) \'\
/.. ·\ \ .. _.,_,,L., I Tank Volume
Tank Exterior
Name · ;..Jtte~t~r:e11:!'ment·Typ~~~:·. _, ;Tank~Type (gal) I Efficiency I Input Rating
Energy Factor or
OWH1
OWH2
195000-Btu/hr
WATER HEATING • HERS VERIFICATldN F"""!il &;: f ~
01 I 02 I 03 I 04 I 05
Name Pipe Insulation Parallel Piping Compact Distribution I Point-of Use I
OHW System -1/1
OHW System -2/1
SPACE CONDITIONING SYSTEMS
01 02 03 04
Insulation Standby Loss
R-value (Fraction)
0 0
0 I 0
06 07
Recirculation Central DHW
Control Distribution
05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
CU1 / E1 :F1 :01 :FAN1 :1 Other Heating and Cooling F1 CU1 / E1 FAN1 01 System
CU2 / E2:F2:02:FAN2:1 Other Heating and Cooling F2 CU2/E2 FAN2 02 System
Registration NU m be r: 216-N0188764A-000000000-0000 Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 20165607-Bowling
Calculation Description: Proposed New Residence
HVAC -HEATING UNIT TYPES
. , 01
" ''
..
,. -
Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd
02 ' -,. -.
' . ., '
03
CF1 R-PRF-01
Page 7 of 9
Name type Efficiency
F1 ·CntrlFurnace -Fuel-fired central furnace '' 80AFUE
F2 CntrlFurnace -Fuel-fired central furnace 80AFUE
HVAC -COOLING UNIT TYPES
'. '' 03 04 -.. 05' ' 06 07 01 02 . . ..
Efficiency Multi-speed
Name System Type EER SEER Zonally Controlled Compressor HERS Verification
CU1 / E1 SplitAirCond 11.7 14 Not Zonal Single Speed CU1 / E1-hers-cool
CU2/ E2 SplitAirCond 11.7 -,,t_ 14 Not Zonal Single Speed CU2 / E2-hers-cool
HVAC COOLING -HERS VERIFICATION _/,/ \ \
t•,,' -
01 '' ,., "{ ·: . Q2;;~,.-" 03 04 05 ' ,'. , : :~.'.I 06 ·,-_, '~ w ~ '-~·-,,,.,..~, ' -~-, ',.:;,.-,,•;"'¥ -Verified Refrigerant
Name
-~:.:.;_\ ' V!:?JifiJ{~·.Ai~;-~~~~ -~ U ~;;Airlfcfvi1raijrtr?tt~,f ~~/fjlti! VerifieiEER 3:'!, Verified SEER Charge ., t V i-~ '"' , t·:~ 1-:m ~'¼~x. ~
CU1 / E1-hers-cool ·' "·R-"'· d \l r : .... ~ :,,/:::-,_ eR4.ire ~il ;~ l\ ti ceso 1J9\ lr:l ~)Not Refflii~ f! f![ Not Required Not Required
CU2 / E2-hers-cool ··:_,.>" "'"~glli(ed ~'1/.;..'.:;',:..,J tJ x;.:;:;::, l: 3501 [J !,:l ~ ~-~·tll6t Re~tit~cl f.!1 ~ ;it~ Not Required Not Required .. . 'Cl. ' •' . .. . ·-..• "',',\ i1-;i ~ r~ """" ~ !wit {{ .J ~§ ~ jil} ~ l"'' .. ~
HVAC -DISTRIBUTION SYSTEMS
01 02 03 . ,. '. 06 04 05 07
Name Type Duct Leakage Insulation A-value Duct Location Bypass Duct HERS Verification
D1 DuctsAttic Sealed and tested 6 Attic None D 1-hers-dist
D2 DuctsAttic Sealed and tested 6 Attic None D2-hers-dist
HVAC DISTRIBUTION -HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target(%) Location Design Ducts Ducts Air Handler
D1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required ---
D2-hers-dist Required 6.0 Not Required Not Required Not Required Not Required ---
Registration Number: 216-N0188764A-ooooooooo-oooo Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 20165607-Bowling
Calculation Description: Proposed New Residence
HVAC -FAN SYSTEMS
,. '" 01
Name
FAN1
FAN2
HVAC FAN SYSTEMS -HERS VERIFICATION
01
Name
FAN1 -hers-fan
FAN2-hers-fan
·\ ,.:~
IAQ (Indoor Air Quality) fANS ! . '\
l_.;,
01 '/\J2
''
Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd
02
,. . ' ., 03.,
Type Fan Power (Watts/CFM)
Single Speed PSC Furnace Fan " ' ' 0.58
Single Speed PSC Furnace Fan 0.58
. " --02,, ''
verified .Fan viratt Draw "
.. " Required
Required
-, ..
03 I 04 1·
) ! ,, ~ ,.,,,,.., ;--..+,....._•
,,
04
CF1 R-PRF-01
Page 8 of 9
HERS Verification
FAN1 -hers-fan
FAN2-hers-fan
03
Required' Fan Efficiency (Watts/CFM)
0.58
0.58
05 I 06
iAQ Recovery
Dwelling Unit IAQCFM .. --:
.i'_, ' IAQFanType Effectiveness(%) HERS Verification
SFam IAQVentRpt 1-1 0 Required
Registration Number: 216-N0188764A-000000000-0000 Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
CERTIFICATE OF COMPLIANCE • RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 20165607-Bowling
Calculation Description: Proposed New Residence
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and.comp.lete.
Documentation Author Name:
David Trimm
Company:
TITLE 24's by LARRY
Address:
4401 W. Judy Ave.
City/State/Zip:
Visalia, CA 93277
RESPONSIBLE PERSON'S DECLARATION STATfMENT
I certify the following under penalty of perjury, unde?the laws of the State of California:
Calculation Date/Time: 12:47, Fri, May 20, 2016
Input File Name: 20165607 _rsu.ribd
• Documentation Author Signature:
Signature Date:
2016-05-20 12:53:42
,«}~ d7 ~
CEA/HERS Certification Identification (If applicabie):
R13-15-10109
Phone:
559-625-8610
CF1 R-PRF-01
Page9 of 9
1. I am eligible under Division 3 of the Businl:iss,cand Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. I certify that the energy features and perform?,i:)ce specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. ,. . . , , :' / '-:'' .. ,.. .• ,·,,,,...
The building design features o.r. sy,:item design'·features id.enti!i~!toncthis·Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans· an~ s~ecifi~aUon~ ~ubct,ittet~q~\h,e enforc,er1e~H2;1.~~-f9I ~Pp_rq,y~~h .. tJ1J~,,!JtJ}lding Prf]mit application.
3.
Responsible Designer Name: 1· ;ResponMble !oesigner Sighatlfre~ ~"'··' tr "'·,~ M n ri
Arlen Roper ' . i ~.,\\ tt ~).) t::r {t t} fl
Company:
Arlen Roper Residential Design •·
Address:
1428 Schoolhouse Way
City/State/Zip:
San Marcos, CA 92078
Right-Suite® Universal 2017 17.0.03 RSU00757
License:
n/a
= , 9 ,UR t"""'ll
-20 i5:39:23J
Phone:
760-522-3997
«~~~
Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-N0188764A-000000000-0000 Registration Date/Time: 2016-05-20 15:39:23 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFlR-04072016-744 Report Generated at: 2016-05-20 12:49:21
2013 Low-Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may avvly. Review the respective code sectionfor more information.
Building Envelope Measures:
§110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)5: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of§ I 0-111 ( a).
§110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§110.S(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§110.S(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of§ l 10.8(i) when the
installation ofa cool roof is specified on the CFlR.
§110.SG): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFlR.
MinimmµR-30 insulation in wood-frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b): Loose fill insulation shajl conform with manufacturer's installed design labeled R-value.
§150.0(c): Minimum R-13 insulati9n in 2x4 inch wood framing wall or have a U-factor of0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).
§150.0(d): Minimum R-19 insulation in raised wood,frame floor or 0.037 maximum U-factor.
§150.0(g)l: In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air-permeable insulation.
§ 150.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and When installed as part of-a heated slab floor meets the requirements of §110.8(g).
§150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of0.58; or the weighted average CT-factor ofall fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)lA: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)lB: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight-fitting damper or a combustion-air control device.
§150.0(e)lC: Masonry or factory-built fireplaces have a flue damperwith a readily accessible control.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HV AC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of§ 110.3( c )5.
Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appli-
§110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
§150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §15.0.0(h)2.
§ 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §l 10.2(c).
§150.0G)lA: Storage gas water heaters with an energy factor equal to 9r less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance ofR-12 or greater.
§ 150.0G)IB: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water-heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.0G)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements ofT ABLE 120.3-
A.
§150.0G)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non-crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 L ow-Ri se R "d es1 f IM en 1a d t an a ory M easures s ummary
§ 150.0(j)2C: Pipe for cooling system lines shall be insulated as specified in § 150.0G)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure> 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.0(j)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.0G)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping ·and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.0(j)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of§ 110.3( c )5.
§ 150.0(n)3: Solat water-heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air-distribution system ducts and plenums installed are sealed and insulated to meet the requirements ofCMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HV AC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply-air and return-air ducts and plenums are insulated to a minimum installed level ofR-6.0 (or higher ifrequired by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l: with mastic, tape, or other duct-closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ¼ inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air ~andlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be·comoressed to cause reductions in the cross-sectional area of the ducts.
Factory-Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6: Field-Fabricated Duct Systems shall comply with requirements for: pressure-sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8: Gravity ventilating systems serving conditioned space have either autqmatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellularfoam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)l0: Flexible ducts.cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§150.0(m)ll: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Aooendix RA3.
Mechap.ical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§ 150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13: space conditioning system mustalso demonstrate airflow~ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air-handling unit fan efficacy~ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Annendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of~ 350 CFM per ton ofnominal cooling
capacity, and operating at an air-handling unit fan efficacy of~ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)lA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Annendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatheroroof plate or card with operating instructions; and shall not use electric resistance heating.
2013 L ow-Ri se R "d es1 t· IM en 1a an d t a ory M easures s ummary
§110.4(b)l: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b )2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p): Residenti_al pool systems or equipment shall meet specified pump _sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of§ 110.9.
§150.0(k)lA: Installed luminaires shall be classified as high-efficacy or low-efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ 150.0(k)lB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the aoolicable provisions of§ 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)lC: § 130.0( c ). In residential kitchens, the wattage of electrical boxes fmished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lil!hting per electrical box.
§150.0(k)lD: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)lE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)lF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of & 150.0(k).
§150.0(k)2A: High efficacy luminaires must be switched separately from low _efficacy luminaires.
§ 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions.
§150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F: Lighting controls comply with applicable requirements of§ 110.9.
An Energy Management Control System (~MCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of§ 130.4; the EMCS requirements of§ 130.5; and all other
requirements in &150:0(k)2.
An Energy Management Control System (EMCS) m11y be used to comply with vacancy sensor requirements of§ 150.0(k) if: it
§150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of§ 130.4; the EMCS requirements
of§ 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other aoolicable requirements in § 150.0(k)2.
§ 150.0(k)3A: A minimum of SO percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ l 50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacv, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)S: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the aoolicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions ofltems ii or iii below; and
§ 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 L ow-Ri se R "d es1 f IM en 1a an d t a ory M easures s ummary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically tum the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically tum the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B: following requirements:
i. Shall comply with§ 150.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by§ 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the annlicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ 150.0(k)lO: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§150.0(k)ll: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)l2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor. _
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k) 12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§110.l0(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of §110.lO(b) through §110.l0(e).
§110.10(a)2: Low-rise multi-family buildings shall comply with the requirements of§ 110.1 0(b) through § 110.10( d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.lO(b)l: buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi-family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent.of the total roof area of the building excluding any skylight area.
§110.10(b)2: All sections of the solar zone located on steep-sloped roofs shaHbe oriented between 110 degrees and 270 degrees of true north.
§110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal proiection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.1 0(b )4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and rooflive load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§110.lO(c): from the solar zone to the point of interconnection with the electrical service ( for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water-heating
system.
§110.l0(d): A copy of the construction documents or a comparable document indicating the information from §110.l0(b) through §110. I0(c)
shall be provided to the occupant.
§110.l0(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
t,r;'I",
(_City of
·Carlsbad
CERTIFICATION OF
SCHOOL FEES PAID
8-34
· Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
This form must be completed by the City, the applicant,. and the appropriate school districts and returned to the City
prior to issuing a building permit. The City wilt not issue any building permit without a completed school fee form.
Project Name _B ___ owl ____ i_n ... g_R_es=id_e_n_c_e ______________________ _
BuilcUng Permit
Plan Check Number __ C __ B __ 1 ___ 6 __ 2 __ 19 __ 5 _______________________ _
Project Address: _.2 .. 7 .... 9.,.2...,J..,,a .. me......,s._D....._r _______ ....,.... ______________ _
A.P.N _1._.5..,.6 ...... -1 .... 4-.2-4......._8-0.......,0 ___________________ _
Proje~t Applicant Mike Bowling (Owner Name) -----------------------------
Project Description: NewSingle Family Residence
Building Type ...... B ... e ... s; .. d...,e...,nt ... ;a_1 __ ........., ____________________ _
Residential: 1 NEW DWELLING UNIT(S)
2,974 Square Feet of Living Ar~a in New Dwelling/s
Second Dwelling Unit Square Feet of Living Area in SDU
Residential Additions: Net Square Feet New Area
Commercial/lr'ldustri~I: Net Square Feet New Area
City Certification of
Applicant Information, S~ Eve-vv Date 08/11/2016
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
!ZI Carlsbad Unified School District O Vista Unified School District D San Marcos Unified School District
6225 El Camino Real 1234 Arcadia Drive 2 5 5 P i c o A v e S t e . 1 O O
Car1sbad CA 92009 (760-331-5000) Vista CA 92083 (760-726-2170) xt San Marcos, CA 92069 (760-290-2649)
2222 Contact: Nancy Dolce (By Appt. Only)
D Encinitas Union SChool District-
By appointment only
0 san Dieguito Union High School District-By Appointment Only
684 Requeza Dr.
101 South Rancho Santa Fe Rd
Encinitas, CA 92024
(760-944-4300 x1166)
Encinitas, CA 92024
(760-753-6491 X 5514)
Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury
that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the owner
will file an amended certification of payment and pay the ackfltional fee if Owner requests an increase in the number
of dwelling units or square footage after the building permit is issued or if the initial determination of units or square
footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or
that the person executing this declaration is auth~ sign on behalf of the Owner.
"' -,,.,.,,;,· __ -----=-.. -·? _.,,,, ... :,2.-/ Date: ---~-#-""'-:,,-'""""-..;;;;,,,,..--==:~-------------Siguature:
8-34 Page 1 of2 Rev.03/09
. ,
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE
PROJECT HAVE BEEN OR WILL BE SATISFIED.
SCHOOL DISTRICT:
The undersigned, being duly authorized by the applicable School District., certifies that
the developer, builder, or owner has satisfied the obligation for school facilities. This is
to certify that the applicant listed on page 1 has paid all amounts or completed other
applicable school mitigation determined by the School District. The City may issue
building permits for this project.
SIGNATURE OF.AUTHORIZED SCHOOL
DISTRICT OFFICIAL
TITLE
NAME OF SCHOOL DISTRICT
DATE
PHONE NUMBER
Tu ,'\:2 -e-<}O C ,i,LuA ~LQ Le. , Gu 'Y\.. b-e\vv\Ci I)'\)
S \A<PJ>x: ,~.~
CARLSBAD UNIFIED SCHOOL DISTRICT
6225 a CAMINO BEAL
CARLSBAD, CA 92009
~-l{)-lh
B-34 Page 2 of2 Rev. 03/09
</ · Ccityof
Carlsbad
CIRCUIT CARD
B-36
Development Services
RECEIVED
JAN 1 7 2017
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE BO NI :ru)fMf&fllt<h10N
Address: 2792 James Drive Permit Number:
Owner: Phone:
Contractor: Phone: Area in Sq. Ft.
PANEL: A.LC. VOLTS. 0 WIRE
LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT SIZE SIZE TYP!= SJZE TYPE SIZE LOCATION
REFER 1 20 12 1 8 40 2 AIRCOND
HOOD 3 20 ·12 1 8 40 4 AIRCOND
KITCHEN 5 20 12 3 8 40 6 AIRCOND
FREEZER 7 20 12 1 8 40 8 AIRCOND
Ul.:it .••. ::;;-1'"1!1". 20 12 1 8 40 10 OVEN
INSTAHOT 11 20 l .! 1 8 40 12 OVEN
KITCHEN 13 20 12 4 6 50 14 SPAPREW
DISPOSAL 15 20 12 1 6 50 16 SPAPREW
KITCHEN 17 .::u 12 4 14 15 18 FIRE BELL
PANTRY. 19 20 12 4 20
MICRO 21 20 12 1 22
KITCHEN :'23 20 12 2 24
· MAS BATH 25 20 12 fj 26
MAS BATH 27 20 12 7 28
WET BAR 29 20 ·12 4 30
31 32
3? 34
35 36
37 38
39 \ 40
41 42
MAIN:~ 2,00 AMP BRK/FUSE D MLO Computed Load 135 AMPS
BUS: 200 AMP See Calculation Worksheet on back
Service entrance or feeder conductors: Branch circuits required:
A)Size: No. B)·Type: D CU DAL A) Lighting Circuits 220-3(b), 4(d)
8) Two Small Appliance Circuits 210-11(e) C) Insulation: D) Conduit Size: C) Laundry Circuit 220-16(b) Service ground/bond:
B) Type: Qf:cu DAL
D) Central !-feating Equipment 422-12
A) Size: No. . 4 E) Bathroom 210-52(d)
C} Clamp location(s):
~UFER 250-S0(c) Remarks:
DWaferPipe 250-104
DGi~§~1~E 250-52
[X .
GFCI locations 210-8, 680-70: I certify.that all terminations have been torqued in acco,rdance with manufacturer's ~ Bathroom(s) D<Kitchen instructions and that the work shown on this circuit card'represents the full extent of
~Garage(s) DHydromassage Tub the work performed under this permit.
Outdoors D Downer
AFCI Protected Circ. 210-12 D Contractor
D Bedroom(s) all lighting D Signed I IM MORFI I I ECEC I Rl\;Qate 12/:3012016
'
8-36 Page 1 of2 Rev. 03/09
SINGLE; FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
found in ARTICLE 220 of the National Electric Code, may be used
1. GENERAL LIGHTING LOADS
Dwelling _______ sq. ft. x 3. VA= 220-3(a) VA
Small appliance loads-220-16(a) 1500 VA x circuits= ____ VA
. Laundry load .:.. 220-16(b) 150_0 VA x circuits = __ -,--_ VA
Gen~ral LightinSJ Total ______ VA
2. COOKING EQUIPMENT LOADS -Nameplate Value
Range ______ VA=
-Cooktop ______ VA=
Oven(s) ______ VA= ·
____ VA
____ VA
____ VA
Cooking Equipment Total. ____ VA
3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
Dryer _____ VA=· .
4. FIXED APPLIANCE LOADS 230-30 {b) (3)
Dishwasher =
Disposal=·
Compactor=
Water Heater =
Hydromassage Bathtub =
Microwave Oven·=·
Built-in Vacuum =
=
5. OPTIONAL SUBTOTAL (Add all of the above totals)
6. APPL YING DEMAND FACTORS -TABLE 220-30
First 10,000 ,VA x 100% =·
Optional Subtotal (from line 5) { Rem~ining ___ VA x 40%=
7. HEATING OR AC LOAD -TABLE 220-30
Larger of the Heating or AC Load =
Dryer.Total. ____ VA
____ VA
____ VA
____ VA
____ VA
____ VA
____ VA
____ VA
____ VA
Fixed Appliance Total ____ VA
____ VA
10,000VA
VA ----
8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) =
____ VA
____ VA
9. MINIMUM SERVICE SIZE = Optional Loads Total =
. · 240Volt
____ An:ipere
(Please put total on front of card under Computed Load)
.;
@:: ..
( City of
Carlsbad
CIRCUIT CARD
8-36
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQ UIPMENT FOR THE ROUGH INSPECTION
Address: 2792 JAMES DRIVE Permit Number:
Owner: I Phone:
Contractor: I Phone: Area in Sq. Ft.
PANEL: A.I.C. VOLTS 0 WIRE
LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT SIZE SIZE TYPE SIZE TYPE SIZE LOCATION
BED3 1 15 14 C !'i 8 5 12 C 20 2 LAUNDRY
BED, BTH2 3 15 14 C 8 5 7 12 \j 20 4 GARAGE
BED2 HALL 5 ·10 14 I.., 2 ~ 12 1 1.:( C £U 6 HOLIDAY --
7 15 -7 !=lTl'IDY 14 ,... 1 12 C
-v 8 GATE
ENTRY 9. 15 14 C 5 3 4 12 C 20 10 BATH GFl1
GAR,KIT 11 . 15 14 \j 15 1 1£ C 20 12 AIR COMP
LAUN,t\11 13 lb 14 C 15 8 15 C 15 14 MASTER BE[
GREAT RM 15 liJ 14 C 14 1.:( 15 C 15 16 MASTERBATI-1
GREAT RM 17 15 14 C 3 7. 2 8 15 C 15 18 MASTER CLO,
19 15 14 C 10 4 2 "u C 20 20 LAUNDRY2 REARSMOKI nn
21 7 --20 22 GARAGE2 C
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 \ 40
41 42
MAIN:O 100 AMP BRK/FUSE O MLO Computed Load AMPS
BUS: 125 AMP See Galculation Worksheet on back
Service entrance or feeder conductors: ~ Branch circuits required:
A)Size: No: 2 B) Type: 0 CU AL A)-Llghtlng Circuits 220 -3(b ), 4( d)
B) Two Small Appliance Circuits 210-11(6) C) Insulation: D) Conduit Size: ___ C) Laundry Circuit 220-16(b)
Service ground/bond: D) Central Heating Equipment 422-12
A) Size: No. B) Type: 0 cu D AL E) Bathroom 210-52(d)
C) Clamp location(s): LAUNDRY SUB PANEL CIRCUITS DUFER 250-50(c) Remarks:
OWaterPipe 250-104
0 Ground Rod 250-52
0
GF~ocatlons 210 -8, 680-70: I certify that all terminations have been torqued in accqrdance with manufacturer's
Bathroom{s) lXKitchen Instructions and that the work shown on this circuit card represents the fulf extent of
lxl Garage(s) OHydromassage Tub the work performed under this permit.
Ix! Outdoors D .OOwner II11711171ORFII I ECECIRIC AFC! Protected Circ. 210 -12 0 Contractor
l:lBedroom(s) OSigned Date 1~73072016
B-36 Page 1 of2 Rev. 03/09
ET
1.
2.
3.
SINGLE FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
found in ARTICLE. 220 of the National Electric Co.de, may be used
GENERAL LIGHTING LOADS
Dwelling 3000 sq. ft. x 3. VA= 22O-3(a) 9000 VA
Small appliance loads -22O-16(a} 1500 VA x 2 circuits= 3000 VA
laundry load-22O-16(b) 150_0 VAx 1 circuits= 1500 VA
General Lighting Total
COOKING EQUIPMENT LOADS -Nameplate Value.
Range VA= VA
Cooktop VA= VA
Oven (s) VA=· 7200 VA
Cooking Equipment Total
ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
Dryer VA=· Dryer.Total
4. FIXED APPLIANCE LOADS 230-30 {b) (3)
Dishwasher = _1_20_0_._VA
.,--5_oo __ VA
____ VA
Disposal=
Compactor=
Water Heater = GARAGE DOOR
Hydromassage Bathtub = AIR COMPRESSOR
Microwave Oven =
Built-in Vacuum =
WINE COOLER =
350 VA
==:2:=00=:o===VA
--.-.:,s=uu.---VA __,.,,...,.,-__ VA
13500 VA
7200 VA
VA
5. OPTIONAL SUBTOTAL (Add all of the above totals)
300 VA
Fixed--A-pp-11-an_c_e Total __ 58_50 __ VA
____ VA
6. APPLYING DEMAND FACTORS -TABLE 220-30
First 10,000 YA x 100% = 1O,OOOVA
Optional Subtotal {from line 5) { Remaining 16550 VAx4O%= 10620 VA
7. HEATING OR AC LOAD -TABLE 220-30 12000 larger of the Heating or AC Load = VA
8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) = 32620 VA
9. MINIMUM SERVICE SIZE = Optional Loads Total = 135 Ampere
240Volt
(Please put total on front of card under Computed Load)
7 , 6/1/6 IJ/i r fZM$J ;tJ JJ6/L w/j'/~ ~ ;}~ f-
f ~ U;k -17 ii, -l/Jl h 7 .
v./\0/lU 9 ( Cl.J"\ -\t) ACf:fi:t:.r.:h:t:;-c'
7/lvt /Ji, G'v1 J;icJ-11' -
. -lf: fe [JI IL 1/
()J{Jr fP f1 "I, -~
jdq/16 ti~ ll ~f tc_
{Gmoot tpYrri) e/lV/tu
o/l D /, 6
rzTj_ /AJ
T ~.
Final Inspection required by:
D Plan D CM&I D Fire D
SW It, fJ 1 '1 [} DISSUED
Approve"ii P-.aw,,
BUILDING I I Iv! lt6
PlANNING ""1(22/ttn
ENGINEERING 't-/o~IG
FIRE Expedite? y N
DIGITAL FILES ReQuired7 y N
HazMat ..
APCD
Health
Forms/Fees Sent Rec'd·
Encina
Fire
HazHealthAPCD II /)
PE&.M .MfT.IAM t./7 / fl,
School rti r\-l.\.., )\,., Jj".(0-[,0
Sewer· r'.£1
Stormwater
Special Inspection
CFD: y ~ l.YI/A,Z--:/J.. {
LandUse: Density: lmpArea: FY: ·Annex:
-
PFF: (YI ""
Comments Date Date Date
Building ul\ut\t,.
Planning (o/0/}.Lo.
Engineering (J) JC\/\\9 <I /-z/JI,
Fire
Need?
/fJ.tt/hnA .,ZJn v-..llAAt .--I . , -
'-.
I Dev.
By ,4.;n
VM cc.
Due? By
y N
y N
y N
y N ,p '---
y N .
y N
y N
y N
Factor:
Date
'-q_Dohe
tJ Done
Cl Done
[J Done
----· ·--------