HomeMy WebLinkAbout2819 LOKER AVE E; ; CB101060; Permit" City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-23-2010 Commercial/Industrial Permit Permit No: CB101060
. Building Inspection Request Line (760) 602-2725
Job Address: 2819 LOKER AV EAST CBAD
Permit Type: Tl Sub Type: COMM
0
5B
Parcel No: 2090831600 Lot#: Status: ISSUED
06/14/2010
KG
06/23/2010
06/23/2010
Valuation: $5,000.00 Construction Type: Applied:
Occupancy Group: Reference #: Entered By:
Project Title: ACUSHNET-NEW WALLS TO CREATE
COUNSEL.OR OFFICE W/DOOR
Applicant:
DBML INC
814 DODSWORTH
COVINA CA 91724
616 966-8666
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Fire Expedited Plan Review
$72.31
$0.00
$47.00
$0.00
$0.00
$1.05
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$1.00
$137.50
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
CANOGA-RINCON LOKER INDUSTRIAL INC
DEPT#207
PO BOX4900
SCOTTSDALE AZ 85261
Meter Size
Add'I Reel. Water Con. Fee $0.00
Meter Fee $0.00
SDCWA Fee $0.00
CFD Payoff Fee $0.00
PFF (3105540) $0.00
PFF (4305540) $0.00
License Tax (3104193) $0.00
License Tax (4304193) $0.00
Traffic Impact Fee (3105541) $0.00
Traffic Impact Fee (4305541) Q $0.00
PLUMBING TOTAL h.~~ $0.00
ELECTRICAL TOTAL G V\,.;.t..,._ $20.00
MECHANICAL TOTAL 1 :\)~ -<1 t,,_6€, $24.00
Master Drainage F~\)t s~Otv ~ -n $0.00
Sewer Fee P \~ . c"-iJ,, $0.00
Redev Parking Fee _.,,...--1._ rt'1 N · $0.00
Additional Fees .... .J"' $0.00
HMP Fee -??
TOTAL PERMIT FEES $302.86
Total Fees: $302.86 Total Payments To Date: $302.86 Balance Due: $0.00
Inspector: ~ Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired.
,r'!" 1./ ~-, _ _..-! •
~ «~ Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717 / 2718/ 2719
Plan Check NoCC> lo t O & D
~ CITY OF
CARLSBAD
JOB ADDRESS
CT/PROJECT#
EXISTING USE PROPOSED USE
CONTACT NAME (If Different Fom App/leant)
ADDRESS
CITY STATE
PHONE FAX
EMAIL
PROPERTY OWNER NAME
ADDRESS
CITY STATE
PHONE FAX
EMAIL
ARCH/DESIGNER NAME & ADDRESS
Fax: 760-602-8558
www.carlsbadca.gov
A,,. c.
SUITE#/SPACE#/UNIT#
# OF UNITS # BEOROOMS # BATHROOMS
GARAGE (SF) PATIOS (SF) DECKS (SF)
ZIP
ZIP
EMAIL
STATELIC. # STATELIC.#
Est. Value 00
Plan Ck. Deposit
Date -IL/~ 10
CLASf 19-J
Fl RE SPRINKLERS
YES D NOD
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law !Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
D I have and will maintain a certificate of consent to self-insure for workers' compensalion as provided by Section 3700 of the Labor Code, for the performance of lhe work for which this permit is issued.
~ have and will maintain workers' comijllnsati<Jll, as requiW!,by Section 700 of the Labor Code, for the performance of the work for which !his permit is issued. My workers' compensation insura~ce carrier and policy
numberare:lnsuranceCo. S 'v'O<./'c. F,. Policy No. 7 / 3-(2 O.)..,'iSVS Expiration Date /-cl O 1/
This section need not be completed if the permit is for one hundred dollars ($100) or less. D Certificate of Exemption: I certify tha · the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to sec e w rkers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensa!io , dama s as r vided for in Section 3706 of the-L~de, interest and attorney's fees.
Ji5 CONTRACTOR SIGNATUR ' F.l -____,/ D AGENT DATE
I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do !he work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply lo an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold wilhin one yearof completion, the owner-builder will have the burden of proving that he did nol build or improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professiohs Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects wilh contractor(s) licensed pursuant to the Con.tractor's License Law).
D I am exempt under Section _____ usiness and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes D No
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. t have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number):
5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone I type of work):
.Ji! PROPERTY OWNER SIGNATURE OAGENT DATE
Is the,applicant or future building occupant required to submit a business p~tely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? D Yes ("? No_
ts the applicant or future building occupant required to obtain a permit from the air pollution control district or air qua~management district? D Yes ~o
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes prro
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction n ng agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name J4--, Lender's Address
I certlfythatl have read the application and state that the above infonnation is correct and that the infonnation on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby aulhorize representative of !he City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARl:SBAD
AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCEOFTHE GRANTING OF THIS PERMIT.
OSHA: An OSHA pennit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every penni!issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such pennit is not commenced within
180 days from the date of such pennit or if e Ilding~rwork authorized by such penntt is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unifonn Building Code).
~ APPLICANT'S SIGNATURE :::, {1 • ----=:, DATE & __. / V -I
City of Carlsbad Bldg Inspection Request
For: 07/19/2010
Permit# CB101060
Title: ACUSHNET-NEW WALLS TO CREATE
Description: COUNSELOR OFFICE W/DOOR
Type:TI Sub Type: COMM
Job Address: 2819 LOKER AV EAST
Suite: Lot: 0
Location:
APPLICANT DBML INC
Owner: CANOGA-RINCON LOKER INDUSTRIAL INC
Remarks:
Total Time:
CD Description Act Comments
19 Final Structural .At_
29 Final Plumbing t= 39 Final Electrical
49 Final Mechanical
Inspector Assignment:
Phone: 8186127045
Inspector: L
Requested By: DAVE MENTO
Entered By: CHRISTINE
---·----------------------------------·-·-
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
PCR00045 ISSUED CHANGES TO EXITS; NON RATED CORRIDOR/ CHANGES TO EXERCISE ROOM
PCR01155 ISSUED DOS GRINGOS-REVISE OPENINGS@; FRONT OF MEZZANINE
PCR06003 ISSUED ACUSHNET BATHROOM PLAN REVS;
PCR10070 PENDING ACUSHNET-REVISE DEMOLITION PLN; REVISE FINISHES, HARDWARE & LIGHTING
PCR99120 EXPIRED REVISE SHAPE OF ROOF SCREENS;
PCR99295 ISSUED ACUSHNET TITLEIST; COLUMN EXTENSIONS & GIRDS FOR WALL PANEL SUPPOR1
Inspection History
Date Description
06/23/2010 14 Frame/Steel/Bolting/Welding
06/23/2010 17 Interior Lath/Drywall
06/23/201 0 34 Rough Electric
Act lnsp Comments
AP TP
AP TP
AP TP 1 SWITCH, (12 RECP DELEATED)
PLANNING/ENGINEERING APPROVAL·S
PERMIT NUMBER CB101060 DATE 6/14/10
ADDRESS 2819 LOKER AV E
RESIDENTIAL ADDITION-
MINOR (<17,000.00)
RETAINING WALL
VILLAGE FAIRE
POOUSPA
TENANT IMPROVEMENT
COMPLETE OFFICE BUILDING
OTHER WALLS FOR A GOLF BALUCLUBS MANUFACTURING
COMPANY
PLANNER GINA RUIZ
ENGINEE~~
11:\ADMIN\COUNTER/PLANNING/ENGINEERING APPROVAI.S
DATE 6/18/10
DATE~/(//; cl
I I
(
CORRECTION LIST BLDG. DEPT COPY
Page:~
Daryl K. James & Associates, Inc.
205 Colina Terrace
Checked by: Daryl K. James
Date: June 18 2010
Vista, CA 92084
T. (760) 724-7001 Email: kitfire@sbcglobal.net
APPLICANT: Dave Minto
PROJECT NAME: Acushnet
JURISDICTION: Carlsbad Fire Department
PROJECT ADDRESS: 2819 Loker Avenue E.
PROJECT DESCRIPTION: CB101060 Tenant Improvement
INSTRUCTIONS
• This plan review has been conducted in order to verify conformance to minimum requirements of codes
adopted by the Carlsbad Fire Department.
• The items below require correction, clarification or additional information before this plan check can be
approved for permit issuance.
• To expedite the reheck process, please note on this list ( or copy) where each correction item has been
addressed, i.e. sheet number, note number, detail number, legend number, etc Corrections or
modifications to the plans must be clouded and provided with numbered deltas and revision dates.
• PLEASE SEND OR DELIVER REVISED PLANS WITH ESGIL COMMENTS DIRECTLY TO:
DARYL K. JAMES
205 COLINA TERRACE
VISTA, CA 92084
ALL COMMENTS ADDRESSED. RECOMMENDED FOR APPROVAL
• Please direct any questions regarding this review directly to: Daryl K. James 760-724-7001 or
kitfire@sbcglobal.net
Applicable Codes
List the following applicable codes:
2007 California Administrative Code (CAC ...................... (Part 1, Title 24, CCR)
2007 California Building Code (CBC), Volumes 1 and 2 ....... (Part 2 Title 24 CCR)
(2006 Edition International Building Code with 2007 California Amendments)
2007 California Electrical Code (CEC)............................ Part 3, Title 24, CCR)
(2005 Edition National Electrical Code with 2007 California Amendments)
2007 California Mechanical Code (CMC)........................ (Part 4, Title 24, CCR)
(2006 Edition IAPMO Uniform Mechanical Code with 2007 California Amendments)
2007 California Plumbing Code (CPC) ............................ (Part 5, Title 24, CCR)
(2006 Edition IAPMO Uniform Plumbing Code with 2007 California Amendments)
2007 California Energy Code ......................................... (Part 6, Title 24, CCR)
(2006 Edition California Energy Commission Building Energy Efficiency Standards)
2007 California Fire Code (CFC) .................................... (Part 9, Title 24, CCR)
(2006 Edition International Fire Code with 2007 California Amendments)
,. Page: 2 of 2
" . Building Data
Building data to include:
a Occupancy classification and size of proposed area.
a Construction type as per 2007 CBC Chapter and verify that the type of materials and degree of fire
resistance for buildings major elements comply with Table 601 and Chapter 7.
a Denote that building is sprinklered.
Floor Plan
a Provide door and hardware schedule and details in accordance with the provisions of the CBC for exit
doors.
a Denote any rated walls on floor plan and reference wall details showing listed design numbers or
reference to CBC Table 720 1 Item number. ICC ESR-2215 not found on ICC report list.
a -Denote type and locations of fire extinguisher in accordance with CFC Sec. 906.
Scope of Work
a Justify no change to fire sprinklers. Denote location of existing sprinkler heads on floor plan.
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS QUESTIONNAIRE
OFFICE USE ONLY
UPFP# _______ _
HV# _______ _
BP DATE _ __. ______ _
~ Business Contact Telephone#
~ l~ Zip Code APN#
LcrtC c..r ,4-,,.~ ,:,, P" I~ J, ¢ J) t!} 7-0/3r lb
City State Zip Code Plan File#
Project Contact
The following questions represent the facility's activities, NOT the specific project description.
PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business
will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with
jurisdiction prior to plan submittal.
1. Explosive or Blasting Agents 5. Organic Peroxides
2. Compressed Gases 6. Oxidizers
3. Flammable/Combustible Liquids 7. Pyrophorics
4. Flammable Solids 8. Unstable Reactives
9. Water Reactives
10. Cryogenics
11. Highly Toxic or Toxic Materials
12. Radioactives
13. Corrosives
14. Other Health Hazards
15. None of These.
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISIONS (HMO): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3m floor, San Diego, CA 92101.
Call (619) 338-2222 prior to the issuance of a building permit. D CalARP Exempt
I FEES ARE REQUIRED. Expected Date of Occupancy: ___ . ___ / _____ / __ _
YES NO
1. D
2. D
3. D
4.
5.
6.
D
D
D
Is your business listed on the reverse side of this form? (check all that apply).
Will your business dispose of Hazardous Substances or Medical Waste in any amount?
Will your business store or handle Hazardous Substances in quantities equal to or greater than
55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity?
Will your business use an existing or install an underground storage tank?
Will your business store or handle Regulated Substances (CalARP)?
Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
Date Initials
D CalARP Required
I
Date Initials
D CalARP 9omplete
I
Date Initials
PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air
Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition
permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to
commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information.
YES
1. D
2. D
Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air-contaminant? (See the
APCD factsheet at http://www.sdapcd.org/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side
of this from. Contact APCD if you have any questions). D (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)?
3. D
4. D
(Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/; or contact the
appropriate school district).
Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos?
Will there be demolition involving the removal of a load supporting structural member?
lo I I YI lo-.
Date
FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _______________________________ _
BY: ___________________________ _ DATE: __ ...._/ __ _./ __ _
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO APCD COUNTY-HMO APCD COUNTY-HMO APCO
HM-9171 (04/07) County of San Diego-DEH -Hazardous Materials Division
i----------
1
I
I
C= I I
r-·------
Ml I
I
Ml I
@: I
C= I
I
{® I
I
I
I
I
i1!1B I
D= I
I
leg I
D!!!J I ~ I
@, I
I
I
.,JJ I
l1!1B I
I
I
I
I
I
I
I -----------
L______ ill' Al /J. @ ~
----Al .ffB -----
I
\
\
·------------
\ . L ________ _ -----.
---------
\
\
\ •• \
\ __ J ---------
-----------
.. !
LEGAL DESCRIPTION:
LOTS 23 AND 38 OF CARL56AD OAKS EA5T,
CARLS6AD TRACT NO. 14-21, CARLS6AD. CA
TENANT / APPLICANT:
TITLEI5T
2819 LOKER AVENl 't:;; EAST
CARL56AD, CA ~· riil<Zl
PROJECT ADDRESS:
2819 LOKER AVENUE EA5T
CARLSBAD, CA 92i'Z>ltZ>
APN:
2tZ>9-083-llo
C i:, //rt;A--c..72 te_
l) 6 /Yl tt;I J;:;1 it.. •
/)nvl.~-JJ4 ,;,1f:o
fl 11 -(,;, JJ. * i O "Is;; .. ·
LOCATION MAP:
-------~--..... .... __ ---~------/J., n liil
--------------.--:-
. TITLEIST
281t~: LOK~R ·AVENUE EAST SITE PLAN. CARLSBAD/'(;ALJFORNIA 92010
5CALE: 1/64' = 1'-i'Z>' . ~----------____:..--:----,--~--..:._---'----.:._:_.,·i--. 7. --~--------
..s-.
.5 I.A,/ , ./ .., I, , ""5 .
tx/e:1/J r· ,.,_, n I I .
. ·-·------;;;;;:,-:------------------.
D IE.TA-1 L p LJAL.L
(OPTION I) PROVIDE I" DEFLECTION WITH 'SLIP-TRAK'
'--"-,,~OR.ATTACH TOP TR.ACK WI 1-1/2" sc= @ I 2"
0.C. STAGGER.ED INTO EXISTING ROOF STRUCTURE.
AND SECOND TR.ACK I " BELOW WITH G'l1'5UM BOARD
,. ~ ATTACHED TO IT ONLY.
_; .... '. ,. ... -•'s (OPTION 2) 3-5/8" 18 GA. DIAG. BR.ACES
{;', , .,-,) / ) STAGGERED AT 48", AT 45°, ATTACH WITH 18 GA.
, , . x ,. U ............ ·· BRACKET WITH SCREWS PER. ICC ESR-1799, AT -..... \ i :< ,,,.,. · /V . STRUCTURE W/ (2) #8 TEK SCREWS AT BRACE FOR.
• 1 ,,, ...... r.x-·· · \' /\ SOLID CONNECTION
[li.{l."lT.:~ ""' "" "'"' "" "-~{ : ;",.~~---~-.:::., .. , .• ,=:... ... ~"",."",.-,.,~~,.......... : ... -,...,,. • • • • • • '· :-,;:·: .. ,_._."""'·"··~--,--·--"";·c;;;~;;~;~;:~::~~:~~;;:~~~~~~"7
n. . .• <.J-·. 'f... DETAIL, TILE PER. SCHEDUlf.. -· · · ~ 1 .•. :•,. j "'-· ---5/8" 1 Yf'E-X GYPSUM BOARD 60TH SIDES, 0\/Ei<
<fl ~,•/ 3-5/8'25GA.METALSTUDS@ 16' O.C.,TYF. ~ , [...-• INSTALL PER. ICC ESR.-221 5 WITH 3-1/2" SOUND
O)
~ 1 ::].').'4' BATT INSULATION, FINISH FER. SCHEDULE , \:.{,, 1 r---1-1 /2' FOWER DRIVEN "ITW R.AMSET TR.ACf;J'AST • WI ><' . V WASHER. @ 36" 0.C. t G" AT ENDS, MIN 2, INSTALL
• ,, .. ··1 ,, .. , PER. ICC ESR.-2579 TYPICAL AT CONCRETE FLOORS
PARTITION lYPE "B"
~
NORTH
'-SQ?
'.D
0
UP
--------------··-------·-----·---·--,---
-Q o--·:.-,.
PROJECT TO COMPLY WITH:
2007 CA BUILDING CODE
2007 CA MECHANICAL CODE
2007 CA ELECTRICAL CODE
2007 CA PLUMBING CODE
2008 CA ENERGY CODE
2007 CA FIRE CODE
CITY OF CARLSBAD MUNICIPAL CODE
UP