Loading...
HomeMy WebLinkAbout2820 Whiptail Loop; ; CBC2018-0295; PermitCommercial Permit Print Date: 04/16/2019 Job Address: 2820 Whiptail Loop Permit Type: BLDG-Commercial Work Class: Cogen Parcel No: 2091202500 Lot#: Valuation: $ 16,000.00 Reference#: Occupancy Group: Construction Type # Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: GATEWAY PACIFIC: INSTALL 8 EV CHARGING STATIONS Applicant: Owner: YOLANDA CALVO 9707 Waples St GATEWAY PACIFIC VIEW LLC San Diego, CA 92121-2954 858-558-4500 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) 4275 Executive Sq, 370 La Jolla, CA 92037-1466 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $ 332.39 Total Payments To Date : $ 332.39 {City of Carlsbad Permit No: CBC2018-0295 Status: Applied: Issued: Permit Fina led: Closed• Expired 05/29/2018 06/20/2018 Inspector: AKrog Final Inspection: Balance Due: AMOUNT $168.18 $117.73 $41.00 $1.00 $4.48 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division EXPIRED PERMIT PERMIT HAS EXPIRED IN ACCORDANCE WITH C B C SECTION 106.4.4 AS AMENDED BY C.M.C.18.04.030 . DATE4-l1.-I'} SIGNATUREt?vt_,~ f _ 1635 Faraday Avenue, Carlsbad CA 92008-7314 \ 760-602-2700 \ 760-602-8560 f \ www.carlsbadca.gov } ( Cicyof Building Permit Application Plan Check No.C'_fr, '1.L I'( ~ LS-\ L~ . Est.Value -$\(p,Ooo 1635 Faraday Ave,, Carlsbad, CA 92008 Carlsbad Ph: 760-6024719 Fax: 760-602-8558 email: bulldlng@carlsbadca.gov Plan Ck. Deposit www.carlsbadca.gov ~ .. ('<,-L"c'. li.. Date ' . 1'r-_, , JOB ADDRESS SUITE#/SPACE#/UNIT# \'uig N~o\-a.il L,ooJO IAJest -BLL< ,,J,[IA,o, f:, . l'1-0 . 1-S . CT/PROJECT '1 IL01"# I PHASE# #OFUNI,~ # BEDROOMS # BATHROOMS I TENANT BUSINESS NAME 11 CONSTR. TYPE I CCC. GROUP I 'P~ c.. Vi ftc._ CC!"MW!Jt< C4 DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) IM-l--n I I h -'--'-; c-t f3 "'-.U<1 Ro chi't 1/d-<,; ck ~,.,,.,,,_. s+.u:icrl'l s . I v~ Ac u •;s, hl~ I '1:,-1. . " ',J f\cu'§.11,i,,;,, ~ "' <;. ~.uri ,~Ur EXISTING USE I PROPOSED USE GARAGE (SF) PATIOS (SF) I DECKS (SF) I FIREPLACE !AIR CONDITIONING l FIRE SPRINKLERS Co l'\,vW\.l,VU. .J) CelVVW\.t,<"C,( J} YES □#_ NO □ YES □ NO □ YES O NO □ At;{cLICANT NAME (Primary Contact) c1,; ,.,w, Wvc £,,., Sl)c,~ PROPERTY OWNER NAME ,ti;_ ,::;A•~. J:bu c V<eM LL.C ,·IA ~,:;\,,v,-Co I Jc /,, ADDRESS V ,,,, , . ';:FHJ".:/ ~s s, ADDRESS • _ ... _.. .... --' -' 42-'IS EY.er u .. t-i'v( -:;.,~ #3q--o --\ I "''-\ ' .. CITY -STATE ZIP CITY La. • STATE ZIP Set.Yt "Diea.,,, Cl4 QZ.. 111 Jo(lq C,V\ q703'f PHONE V I FAX PHONE I FAX 8<;f:,-S:<;;f; -'{-Sot, ese-e1 z.-:pj (,o EMAIL EMAIL ~ CAfVt?C ~s~ St>. Co iV\ du-7 s , wood<? ~ a.+i Wf\'\Pc:tMA't"~. CCIVV\ DESIGN PROFESSIONAL NAME 'j~ C~o CONmACTOR BUS. NAME Ue,4'\l:-e,U ll.. "" c.f.,o L.I ADDRESS ADDRESS - <J-W't Wa.t>us S:·L ,2-"f-(., L. r., k-tw<:ure ~ iF;z,,:,o CITY Sc:u,, Die.'.k> STATE ZIP CITY STATE ZIP a<\ <J'Z-11/ s: cu-, l) I ep,-o C\<\ ~'2-123 PHONE V I FAX PHONE I FAX BSt -<;<;8-· "I-SOO 909-T"l-2--3 s-:n. EMAIL EMAIL Y(AQ.,vc l' f-/U .. vl!;a.W S'b COM ol l"Oc:ll,e,J,,,, I? '1-e 1\.1<-e.ls-COW\ STATE UC.# STATE LIC.# l~LA~'io C-lls~~~,~~c,4-sas lo 151-"l-193l93 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also re_quires the applicant for such per_mit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License LawJChapter 9, commending with Section 7000 of Division 3 of the B_usIness and Professions Code} or [hat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 031.5 by any applicant for a permit subjects the applicant to a c1vII penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of pe(jury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. r," I have and will maintain workers' compensalion, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. t..O,ex±tf (n Sµ...Va,.,C,j,,,c,Q,, 0, ¥F Policy No. INl\3-' 3h:00!100 2.. Expiration Date lo{ 0, I IA This section need not be completed if the permit is for one hundred dollars ($100) or less D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure worker ' ensation cover is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensaron, d g 3706 of the Labor code, interest and attorney's fees. ~ CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the worll and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply lo an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such illl)rovements are not intended or offered for sale, \f, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement □ Yes □ No 2, I (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number) 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address/ phone/ contractors' l'cense number) 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated {include name I address/ phone I type of work): ,A$ PROPERTY OWNER SIGNATURE □AGENT DATE (,,, r ,/:OMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes 'ti No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED ur-Afss THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY APPLICANT CERTIFICATION I certify that I ha~ read the application and state that the above infonnatlon Is correct and that the infonnation on the plans is accurate. I agree to comply with all City ordinances and State I~ relating to bunding construction. I hereby autholize representative of the City of Carlsbad lo enter upon the-. mentimed properlyfcr irepeclon purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARM-ESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHApemiit is required for excavations over 5'0' deep and demolition or construction of struchJres over 3 stories in height. EXPIRATION: Every permit issued by the Buikling · I under the provisions of this Cooe shall expire by limitation and become null and void if the building or'o\00(. authorized by sudl permit is not commenced with"n 180 days from the date of such permit or· the ilding or auth by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unifcxm Building Cooe). AS APPLICANT'S SIGNATURE oATE s/z.s I /f, January 14, 2019 YOLANDA CALVO 9707 WAPLES ST SAN DIEGO, CA 92121-2954 RE: BUILDING PERMIT EXPIRATION PERMITlYPE: BLDG-Commercial, Cogen {city of Carlsbad PERMIT NUMBER: CBC2018-0295 ISSUE DATE: 06/20/2018 ADDRESS: 2820 Whiptail Loop Carlsbad, Ca 92010 our records indicate that your building permit will expire by limitation of time on 03/13/2019. 18.04.030 Section 105.5 amended -Expiration: Every permit issued by the Building Official under the provisions of this code shall expire by limitation and beoome null and void if the building or work authorized by such permit is not commenced within 180 calendar days from the date of such permit, or if the building or work authorized by sud\ permit is stopped at any time airer the work is commenced for a period of 180 calendar days, or if the building or work authorized by such permit exceeds three calendar years from the issuance date of the permit. Work shall be presumed ID have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 calendar days of the date of permit issuance. Work shaD be presumed ID be stopped if the permittee has not obtained a required inspection approval of work by the Buading Official within eadl 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained ID do so, and the fee therefore shall be one half !he amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications fur such work, and provided further that such suspension or abandonment has not exceeded one year. In order ID renew action on a permit after expiration, the permittee shall pay a new permit fee. Any permittee holding an unexpired permit may apply fur an extension of time within which work may commenm under that permit when the permittee is unable to commence work within the time period required by this section fi:>r good and satisfactory reasons. Please check below indicating your intentions and return this letter to us. D Project abandoned. A new permit will be obtained prior to commencing work. D Permit 180 day extensiOn request, with written explanation including phone number and email address. Request will not be considered without explanation D Renewal permit requested. If the p:roject has been completed and only a final inspection is needed, please call the inspection request Rne at (760) 602-2725. If you have any questions, please con tact the Building Inspection Division at 760-602-2700. Community & Economic Development Building Division I 1635 Faraday Avenue, Carlsbad, ·cA-92008-7314 I 760-602-2700 I 760-602-8560 f I www.ca-rlsbadca.gov PERMIT INSPECTION HISTORY REPORT (CBC2018-0295) Permit Type: BLDG-Commercial Application Date: 05/29/2018 Owner: GATEWAY PACIFIC VIEW LLC Work Class: Cogen Issue Date: 06/20/2018 Subdivision: Status: Closed -Expired Expiration Date: 03/13/2019 Address: 2820 Whiptail Loop 11599 Carlsbad, CA 92010 IVR Number: Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 06/21/2018 06/21/2018 BLDG-31 061792-2018 Passed Andy Krogh Complete Underground/Condu it-Wiring Checklist Item COMMENTS Passed BLDG-Building Deficiency South side of 2800 Yes 09/14/2018 09/14/2018 BLDG-34 Rough 070111-2018 Partial Pass Andy Krogh Reinspection Incomplete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial underground Yes April 16, 2019 Page 1 of 1 -Carlsbad CBC2018-0295 6/20/2018 DATE: 6/20/2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0295 ✓• EsG1I A SAFEbu1lt Company SET: II PROJECT ADDRESS: Whiptail Loop West Building B □ APPLICANT □ JURIS. PROJECT NAME: Vehicle Charger additions to Building B parking lot ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise~ applicant that the plan check has been completed. Person contacted: 1/ Te~~one #: Date contacted: / (by:~ Email: Mail Telephone Fax In Person 0 REMARKS: By: Morteza Beheshti EsGil 6/15 Enclosures: DATE: 6/7/2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0295 ✓• EsG1I A SAFEbuilf Company SET: I PROJECT ADDRESS: Whiptail Loop West Building B 9 APPLICANT fJ JURIS PROJECT NAME: Vehicle Charger additions to Building B parking lot D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gJ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [gJ The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. [gJ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Yolanda Calvo Telephone#: 619.281.5937 Date contacted: bl& \lg-(by:~ Email:ycalvo@hansakersd.com ~I Telep~ -t.-r,.l~ln Person 0 REMARKS: By: Morteza Beheshti EsGil 5/29 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2018-0295 6/7/2018 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0295 PROJECT ADDRESS: Whiptail Loop West Building B DATE PLAN RECEIVED BY ESGIL: 5/29 REVIEWED BY: Morteza Beheshti FOREWORD (PLEASE READ): DATE REVIEW COMPLETED: 6/7/2018 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. 1. Please make all corrections and submit Two new complete sets of prints, to the EsGil Corporation. Please note: Before correcting the plans, you should wait until you've received comments from other city departments (Fire, Planning, etc.). 2. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. 3. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list?□ Yes □ No Carlsbad CBC2018-0295 6/7/2018 4. Please provide the technical electrical power requirements and brochure for the chargers. Long Continuous loads must be included for all chargers without a demand factor. 5. On 2 sheet 8 of 9 describe key note 8 or correct note number. 6. Detail the hand hole box and cover for traffic rated installation. 7. Sheet 2 of 4 describe note 40 and item 11 is missing. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Morteza Beheshti at Esgil. Thank you. Carlsbad CBC2018-0295 6/7/2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Morteza Beheshti PLAN CHECK#.: CBC2018-0295 DATE: 6/7/2018 BUILDING ADDRESS: Whiptail Loop West Building B BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 UBC Building Permit Fee • ! Erort youcneeked Comp. Review and R'ourly at the same time 1997 UBC Plan Check Fee Type of Review: D Repetitive Fee ,.. I Repeats • Based on hourly rate Comments: -1 --~ Complete Review □ Other 0 Hourly EsGil Fee Reg. VALUE Mod. D Structural Only ~---~1Hr.@ * ($) 16,000 16,000 s1s1.a1 I $109.0BI Sheet 1 of 1 • CT 4000 Family ChargeP01nt" Level 2 Commercial Charging Stations The CT 4000 family is the latest generation of ChargePoint commercial charging stations. Refined yet rugged, these stations set the industry standard for functionality and aesthetics. The CT 4000 full motion color LCD display instructs drivers and supports dynamic updates of custom branded videos and advertisements. Intelligent power management options double the number of parking spaces served by allowing two charging ports to share a single circuit. Sites with single port EV stations can upgrade to dual port stations without requiring additional electrical services. The CT 4000 is the first ENERGY STAR' certified EV charger because it charges efficiently and conserves power when not charging. As an ENERGY STAR certified EV charger, the CT 4000 uses significantly less energy than a standard EV charger when in standby mode to help you save money on your utility bill. All CT 4000 models offer one or two standard SAE J1772'" Level 2 charging ports with locking holsters, each port supplying up to 7.2kW. With this standard connector, ChargePoint level 2 stations can charge any EV. Stations are available in bollard and wall mount configurations for easy installation anywhere. All stations are fully software upgradeable remotely over the air. Stations come in both 6' and 8' tall models with 18' and 23' cords, respectively. With multiple options for size and cord reach, your station can service up to four parking spaces, reach all car models regardless of parking style or car sizes and increase the usability of your EV spots. Driver Friendly User Interface • Instructional video shows how to use the station + Multi-language: English, French, Spanish -1 Touch button interface; works in rain, ice and with gloves Backed by ChargePoint's world class 24/7 driver phone support Easily Communicate with Your Drivers Whether you're a retail establishment wanting to advertise your latest product, a workplace looking to communicate with employees or a municipality wanting to welcome visitors, ChargePoint's prominent LCD screen makes it easy to reach EV drivers: Daylight readable, with auto brightness control 640 X 480 resolution active matrix Full motion 30fps video support Upload up to 60 seconds of high quality video on a color LCD screen to individual stations as often as desired Brand your charging stations to communicate with drivers Instructional video in English, Spanish or French -chargepoi~l~ -13~1§;JriiiM;i The First ENERGY STAR' Certified EV Charger ChargePoint CT 4000 Family Service Products and Support ChargePoint offers world-class service products and support that help ensure quality of work, save time and money, protect your investment and enhance the productivity of your charging stations. From site planning to installation and setup, to ongoing care and management, when you choose ChargePoint, you're covered. + Charge Point Configuration and Activation: customized setup and activation of your stations + ChargePoint Assure: the most comprehensive EV Station maintenance and management in the industry Energy Measurement and Management ~ Real-time energy measurement + 15 minute interval recording Time of Day (TOD) pricing Load shed by percentage of running average or to fixed power output Minimize Costs with Flexible Power Management Options In the vast majority of applications, a full power configuration is the best choice for both station owners and drivers. However, when drivers are parked for a longer time, an intelligent, lower power output can save station owners considerable installation cost while still providing drivers a great charging experience. With flexible power options, station owners can meet the needs of drivers while lowering costs: Power Select (Patent Pending) + Allows for a lower capacity (less than 40A) circuit to power each port Cuts installation costs by reducing the cost or even avoiding the need to upgrade panels or transformers Power Sharing Dynamically share one 40A, 30A or 20A circuit between two parking spaces Doubles the number of parking spots served while reducing installation and operating costs -1 Allows station owners to upgrade a single port station to dual port to serve more drivers with no electrical upgrade Clean Cord Technology Keep charging cords off the ground Standard on all models 1 Ultra-reliable second-generation gravity operated mechanism , Flexible over entire -40°F to +122°F product temperature range Safe, Reliable, Energy Efficient Hardware ~ UL listed, meeting the stringent requirements of the nation's leading safety standards organization Stations are rugged, built to withstand the elements Safe, Reliable and Energy Efficient ENERGY STAR certified, charges efficiently and conserves power when not charging 2 chargepoint.com When Charging is Mission Critical, Protect Your Investment with ChargePoint Assure • Minimize downtime: ChargePoint Assure provides the most comprehensive EV Station maintenance and management in the industry -1 Get up and running quickly and flawlessly: Professional guidance for station configuration saves you time, and unlimited changes to station policies flexibly supports your business Eliminate unexpected future expenses: Cost for parts and on-site labor to install is covered for all Assure eligible repairs ..; One less thing to worry about: Proactive station monitoring provides you with regular reporting Reduced risk of downtime: We guarantee 98% annual uptime and one business day response to requests Support when you need it: We're there for you and your drivers. Phone support available for station owners Monday to Friday from 5 AM to 6 PM Pacific. Phone support for drivers is 24/7/365, so you never need to field a driver call Ultra-reliable second-generation gravity operated mechanism. 18' and 23' cords to reach all car models and serve more parking spaces World-class 24/7 driver phone support. lnstructionill video shows how to use the station Multi-language charging instructions, giving drivers the choice of English, French or Spanish. Driver interaction 1s supported in any weather by five rugged, bacH1t buttons with audio feedback Strong and rugged design materials built to withstand the elements CT 4000 stations come with 18' or 23' cords to increase the usability of your charging spots. on 6' and 8' tall models respectively CT4021 Dual port bollard charging station with 18' charging cables Standard EV Chargrng Only sign without optional custom branding Promote Your Brand and Business Having your stations installed in a visible location makes a bold statement about your business' commitment to sustainability and shows that you care about your customers. ChargePoint CT 4000 stations are built for customization so you can conveniently promote your brand as well. With custom signage and video you can: + Increase brand recognition + Attract EV drivers by making sure your stations are highly visible Ensure EV charging installations are consistent with the look and feel of your brand + Differentiate your stations from standard ChargePoint stations to make them easily identifiable by your driver base Br~nderl CT 4021 Shown with optional br,mdmg on bollard. 18' cords on 6' model Easily customi2able branding area. All stations come with EV Charging Only sign, wh1Ch can be replaced with your custom signage 5. 7" color LCD display for customizable video content. Upload up to 60 seconds of high quality video to individual stations as often as desired Daylight readable with nuto brightness control. OPTIONAL· Additional customiLable branding areas All stations have standard extrusions to hold your custom signage. · Artwork templates and material specifications are conveniently downloadable from chargepoint.com Branded CT 4025 Shown witil optional branding on back 23' cords on 8' model -charge1H1ln, chargepo1nt.com 3 ChargePoint CT 4000 Family Bollard Charging Stations CT4011 CT4021 CT4025 I Wall Mount Charging Stations -chargepoin+ ChargePoint. Inc. 240 East Hacienda Avenue Campbell, CA 95008-6617 USA +1.408.841.4500 or +1.877.370.3802 US and Canada toll-free chargepoint.com CT4013 Contact Us 01 Visit charaeooint.com ~! Call +1.408.705.1992 ©1 Email sales@charaeooint com CT4023 CT 4027 Copyright£ 2018 ChargePomt, Inc All rights reserved. CHARGEPOINT 1s a U.S. registered trademark/service mark, and an EU registered logo mark of ChargeP01nt. Inc. All other products or services mentioned are the trademarks, service marks, registered trademarks or registered service marks of their respect,ve owners BR-CT 4000-05 April 7018. PN 73-001061-01-6 Listed by Underwriters Laboratories Inc ,@us LISTED .. .. SCOPE: THIS STANDARD SHOWS THE INSTALLATION AND MATERIAL REQUIREMENTS FOR A 3313 HANDHOLE. "P" = PARKWAY COVER "fl FCIBIC" IF THE CUSTOMER IS _.,,c:::_-- REOUIRED TO INSTALL A HANDHOLE IN A SERVICE LATERAL, THE LID SHALL BE MARKED .El ECIBIC" NOT SDG&E. 6" TOP SECTION WEIGHT: 285 POUNDS (MAX.) 6" INTERMEDIATE EXTFNSION SECTION WEIGHT: 267 POUNDS (MAX.) (TO BE ORDERED ONLY FOR ADOITlONAL HEIGHT) 1 B" BASE SECTION WEIGHT: 885 POUNOS (MAX.) 7 2 TON , LIFTING ~~f. ANCHOR 1 EA. SIDE OR 1 EA. END 4" OR 5" x 10" KNOCKOUT -1 EACH SIDE @ 1996. 2016 San Diego Gas & Electric Company. All rights reserved. Removal of this copyright notice without permission is not permitted under law. REV C B A CHANGE BY DSGN APPV DATE REV CHANGE BY DSGN APPV DATE F E EDITORIAL CHANGES JS TR MDJ 5/26/2016 D Indicates Latest Revision Completely Revised New Page Information Removed SHEET 1 OF 3 SDG&E ELECTRIC UNDERGROUND STANDARD HANDHOLE (INSIDE DIMENSIONS · 24" x 36") UG 3313.1 NOTES: I. HANDHOLE SECTIONS AND PARKWAY COVERS FROM DIFFERENT SUPPLIERS ARE INTERCHANGEABLE. II. THE PREFERRED LOCATION FOR A 3313 HANDHOLE IS IN NON-VEHICULAR TRAFFIC AREAS (BEHIND CURBS, PARKWAY POSITION, ETC.). USE A PARKWAY COVER IN THESE AREAS. DI. HANDHOLES WITH A TRAFFIC COVER MAY BE INSTALLED IN AREAS WITH VEHICULAR TRAFFIC, BUT ONLY WHEN THERE IS NO NON TRAFFIC LOCATION AVAILABLE. IV. LIFTNG ANCHORS ARE NOT TO BE USED FOR CABLE PULLING. BILL OF MATERIAL FOR PARKWAY 3313 HANDHOLE: TEM DESCRIPTION QUANTITY STOCK STOCK ASSEMBLY UNITS NUMBER NUMBER 1 COVER, PARKWAY 1 S286834 COMPLETE 3313CP 3 TOP SECTION, 6" 1 S336218 PARKWAY -HANDHOLE COMPLETE 4 BASE SECTION, 18" 1 S162664 S400300 -PARKWAY HANDHOLE 5 BOLT, PENTAHEAD 1/2" X 1-1/2" 6 S156004 - 3313PC 6 SEALANT, PLASTIC-MASTIC AS REQ'D S631872 - 7 EXTENSION SECTION, INTERMEDIATE, 6" AS REQ'D S336368 -3313X1 - 8 LUBRICANT EZ-1 AS REQ'D S469764 --- BILL OF MATERIAL FOR TRAFFIC 3313 HANDHOLE: TEM DESCRIPTION QUANTITY STOCK STOCK ASSEMBLY UNITS NUMBER NUMBER 2 COVER, TRAFFIC (STEEL) 1 S286838 COMPLETE 3313TO 3 TOP SECTION, 6" 1 S336218 TRAFFIC -HANDHOLE COMPLETE 4 BASE SECTION, 18" 1 S162664 -TRAFFIC S400302 HANDHOLE 5 BOLT, PENTAHEAD 1/2" X 1-1/2" 6 S156004 -3313TC 6 SEALANT, PLASTIC-MASTIC AS REQ'D S631872 - 7 EXTENSION SECTION, INTERMEDIATE, 6" AS REQ'D S336368 -3313X1 - 8 LUBRICANT EZ-1 AS REQ'D S469764 --- INSTALLATION: A. ESTABLISH THE HANDHOLE LOCATION PAYING PARTICULAR ATTENTION TO GAS AND FOREIGN UTILITY PLACEMENTS. RELOCATING THE HANDHOLE REQUIRES PRIOR APPROVAL FROM A CUSTOMER PROJECT PLANNER. 8. AFTER THE LOCATION IS ESTABLISHED, MARK OUT DIMENSIONS FOR THE EXCAVATION WIDTH, LENGTH AND DEPTH PER DRAWING BELOW. THE WIDTH AND LENGTH DIMENSIONS GIVEN ALLOW EXTRA SPACE FOR SETTING THE SUBSTRUCTURE AND TAMPING THE BACKFILL. @ 1998 -2016 San Diego Gas & Electric Company. All rights reserved. Removal of this copyright notice without permission is not permitted under law. REV CHANGE BY DSGN APPV DATE REV CHANGE BY DSGN APPV DATE C F B E A EDITORIAL CHANGES JS TR MDJ 5/26/2016 D ·-¥·1 Indicates Latest Revision [ I Completely Revised I New Page I I Information Removed SHEET SDG&E ELECTRIC UNDERGROUND STANDARD 2 OF 3 HANDHOLE UG 3313.2 (INSIDE DIMENSIONS -24" x 36") TYPICAL Pl AN VIEW EXCAVATION DIMENSIONS /s §PROPER~ ~~• •oc • w ~'" WITHOUT SIDEWALK \ 36" WIDE X 46" LO~ \;INAL ®-__ CABLE TAP WITH SIDEWALK GRADE (IF REQUIRED) VS°IDfW~L~'.: 6" TOP SECTION 4 'II,,,' ~ ~ I I \ 24" SIDEWALK---' / ;,; 18" BASE SECTION 1/, J ( HANDHOLE MAY BE INSTALLED ON EITHER SIDE OF LOT LINE OR IN CENTER OF 1/ LOT LINE IN AREA WITH LIMITED SPACE. BUTT AGAINST BACK OF SIDpiALK 7 C. TO DETERMINE FINAL GRADE, MEASURE FROM THE TOP OF CURB OR ESTABLISHED GRADE. D. EXCAVATION IS NOW PREPARED FOR INSTALLATION OF SUBSTRUCTURE SECTIONS. SET HANDHOLE AT FINAL GRADE. PLACE PLASTIC-MASTIC SEALANT BETWEEN ALL SECTIONS. 0 APPLY LUBRICANT (EZ-1) TO THE BOLTS WHEN SECURING THE COVERS TO REDUCE REMOVAL OR INSTALLATION DIFFICULTIES. TIGHTEN DOWN BOLTS WITH TORQUE WRENCH TO 30 FT./LBS. MIN., 40 FT./LBS. MAX. © IF RIGHT OF WAY OR OBSTRUCTIONS CAUSE A PROBLEM, THE HANDHOLE MAY BE TURNED TO WHERE THE LONG SIDE OF THE HANDHOLE PARALLELS THE SIDEWALK OR PROPERTY LINE. IF THE HANDHOLE HOUSES A CABLE TAP, THE HANDHOLE IS NOT TO BE TURNED AND THE TYPICAL PLAN VIEW OUTLINED IN THE STANDARD MUST BE FOLLOWED. (CABLE TAP IS MOUNTED ON THE END OF HANDHOLE AND THE 5 FOOT CLEARANCE FOR HOT STICK OPERATION WOULD BE ON THE SIDEWALK SIDE). NOTES: LOCATE SECONDARY CONDUITS WITHIN 12 INCHES OF THE END OF THE HANDHOLE CLOSEST TO THE SIDEWALK. REFERENCE: 0 SEE STANDARD 3211 FOR INSTALLATION OF IDENTIFICATION TAG. b. SEE STANDARD 3302 FOR SUBSTRUCTURE APPLICATIONS. c. SEE STANDARD 3306 FOR INSTALLATION OF PLASTIC-MASTIC SEALANT. d. SEE STANDARD 3483 FOR MINIMUM OPERA TING CLEARANCE REQUIREMENTS. e. SEE STANDARD 3485 WHEN SETTING HANDHOLE ON A SLOPING GRADE. f. SEE STANDARD 3486 FOR RETAINING WALL REQUIREMENTS AND CLEARANCES FROM REVERSE SUBGRADE RETAINING WALLS. g. SEE STANDARD 3605 FOR SUBSTRUCTURE USE AND LIMITATIONS REFERENCE SHEET (MAXIMUM NUMBER OF CABLES, CONNECTORS AND CONDUITS). h. SEE STANDARD 3660 FOR CABLE TAP, GROUND GRID AND CONDUIT INSTALLATION ON 6.9 ONE-PHASE SYSTEM. i. SEE STANDARD 3312 FOR POSITIONING SECONDARY CONDUITS j. AVAILABLE IN SERVICE STANDARDS AND GUIDE MANUAL. © 1998 -2016 San Diego Gas & Electric Company. All rights reserved. Removal of this copyright notice without permission is not permitted under law. REV CHANGE BY DSGN APPV DATE REV CHANGE BY DSGN APPV DATE C F 8 E A EDITORIAL CHANGES JS TR MDJ 5/26/2016 D X·J Indicates Latest Revision [ I Completely Revised I New Page 1 I Information Removed SHEET SDG&E ELECTRIC UNDERGROUND STANDARD 3 OF 3 HANDHOLE UG 3313.3 (INSIDE DIMENSIONS -24" x 36")