Loading...
HomeMy WebLinkAbout2840 LOKER AVE E; ; CB062225; Permit., t City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 . 09-1-3-2006 Plumbing Permit Permit No: CB062225 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: 2840 LOKER AV EAST CBAD St 101 PLUM Status: Parcel No: 2090820800 Lot#: 0 Applied: Construction Type: NEW Entered By: Reference #: Project Title: SELTZER TECH-INSTALL 2 SUMP PUMPS & 1 CLARIFIER Applicant: DRUM PLUMBING Plumbing Issue Fee Fixture or Trap Building Sewer Roof Drain Install/Repair Water Line Water Heater and/or Vent Gas Piping System Vacuum Breaker Other Plumbing Fees Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES 0 0 0 1 0 0 0 Plan Approved: Issued: Inspect Area: Owner: FENTON HG CO 7577 MISSION VALLEY RD SAN DIEGO CA 92108 ISSUED 08/04/2006 LSM 09/13/2006 09/13/2006 $20.00 $0.00 $0.00 $0.00 $7.00 $0.00 $0.00 $0.00 $180.00 $0.00 $0.00 $0.00 $207.00 Total Fees: $207.00 Total Payments To Date: $207.00 Balance Due: Inspector: Jlflt ~ FINAL A~~RQVAL Date: ol. rz..t; j o 7 Clearance: $0.00 NOTICE: Please take NOTICE that approval of your project includes the "lmpo;ition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exnired. FOR OFFICE USE ONLY PERMIT APPLICATION PLAN CHECK NO. &..g 0/o d'o--05 CffY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. __________ _ Plan Ck. Deposit ________ _ Validated By ___ 01,,..,....~.....,..~~~-- Date ______ .,,~--~.._,_..""'-.;..._--- Address (include Bldg/Suite #) Business Name (at this address) Tea. 6-} Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Assessor's Parcel # Existing Use Proposed Use SQ. FT. f l.)...lrf\ f ~ ( #of Sct1~ 1 f I_ vf Bed:ooms-. ----==#:::o_f_B_athrooms Name Xi-. -A~J?I.ICANt '/J, . ~W'\ r Name Telephone# 97-/f!C ' _l'CC..c>/ZO Name : ~;,:-: ~q,0:tfrif,ii.~T9Ff; :cq1Y1Pf\!11Y: :111p.fy(~. · • - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation otSectiol\703L5 by any applicant for a permit subjects the applicant to a Gi1/il penalty of not more than five hundred dollars [$50~ ..,..._,..,,.,.._ u 1..1tJ4.,...t --7-s-st:> For fJ,e, v: £n4 cft c::>rz ... oz.. 7J 1 '5178-JJ8f:, Name Address City State/Zip Telephone# License Class (, 5 &? City Business License# / Z/8 7 5 7 • Designer Name Address City State/Zip Telephone State License # _________ _ ~E?,~-"_' -WQR1{ERS~ (56MPlN$'AiX9N ~ ::-. , ,, l • , -, , , • • --~ • ,,q ~ ,Wo~s' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I.ZY~ have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance .,/ of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: lnsuranceCompany eAr:MecS PolicyNo. IJ-Z..o/o-7.,/-4& ExpirationDate "Z/I /?') (TH~ECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Ii!(' CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure r ers 'on coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred :~~~s;~~::11 100,00 '. to the cost o ompensation, damages as provided for in Section 3~~T:f the Laboryi/J.@azattorney's fees. ~~11:.UU.UIJ.U;,IJ.llll ...... ~~-· . : ... . .. -, . I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of safe). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(sl licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name I address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number):. _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): _______________________________________________________ _ PROPERTY OWNER SIGNATURE ______________________ _ DATE _________ _ . CQM~t!J;fi; 11'!'1,I~ ):lEO'IJO'II! FO~ NQJV;R~~l.£1fNTIAL 'BUll;DIN~1(>ER1\111t~ ON(. Y Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. lf.l,_,_C9.l'll?JijlJQ1:l9J\IJ;,l;N,l?ll'l.G.AQE!'1CY.:. , . . , ,-·, , -"· ,, ,, , -, .. > .. , ... :, ,, ,. ," ,.,,,,., ,.· I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME _____________ _ LENDER'S ADDRESS _______________________ _ :~.; , ,Al",PPQANt'CJ;:f!JlEIQAT{QN: · ,·· I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSI-IA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not c ce wI days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is c, menced lo a period of days (Section 106.4.4 Uniform Building Code). DATE _e~f_tJ---<-½.<-½_o_..6"'--_ City of Carlsbad Bldg Inspection Request For: 01/24/2007 Permit# CB062225 Title: SELTZER TECH-INSTALL 2 SUMP Description: PUMPS & 1 CLARIFIER Type: PLUM Sub Type: Job Address: 2840 LOKER AV EAST Suite: 101 Lot 0 Location: OWNER FENTON H G CO Owner: FENTON H G CO Remarks: ~ City_:s-erofJ~laTI-s::iLy_o_u_ne::J Total Time: CD Description Act Comment Inspector Assignment: MC Phone: 7605983786 Inspector: Requested By: TERESA Entered By: CHRISTINE 29 Final Plumbing j::L __________ _ Comments/Notices/Holds Associated PCRs/CVs Original PC# lns12ection Histor:y Date Description Act lnsp Comments 09/21/2006 14 Frame/Steel/Bolting/Welding WC MC 09/21/2006 21 Underground/Under Floor AP MC CLARIFER UNDER TEST, OK TO BACKFILL 09/21/2006 24 Rough/Topout AP MC 09/21/2006 34 Rough Electric WC MC 09/21/2006 44 Rough/Ducts/Dampers WC MC 09/19/2006 21 Underground/Under Floor AP MC EsGil Corporation In (J!artnersnip wit/i, (]overnment for (}Juifaing Safety DATE: 9/13/06 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-2225 PROJECT ADDRESS: 2840 Loker Ave East SET: II PROJECT NAME: Seltzer Nutritional Technologies -TI D APPLICANT D JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. [ZI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. · D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [ZI Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person !ZI REMARKS: Per phone conversation with Mike Peterson the City of Carlsbad will permit the sanitary waste to be pumps. By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: LOG trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 I :f "''".yr EsGil Corporation In (Partnersli.ip witli (]overnment for <BuiCaing Safety DATE: 9/6/06 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-2225 PROJECT ADDRESS: 2840 Loker Ave East SET: II PROJECT NAME: Seltzer Nutritional Technologies -TI DA~T <E[Ju . D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. lZJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. lZJ The applicant's copy of the check list has been sent to: Drum Plumbing / Kevin Drum 2550 Fortuna Way, Vista, CA 92083 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kejn Drum . Date contacted: 'f /<R /(Jf;<b¥116) Mail Telephone ~x v1n Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Telephone#: 760-598-3786 Fax #: 760-598-3780 Enclosures: 8/28/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Ci~y of Carlsbad 06-2225 9/6/06' RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2840 Loker Ave East DATE PLAN RECEIVED BY ESGIL CORPORATION: 8/28/06 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): PLAN CHECK NO.: 06-2225 SET: II DATE RECHECK COMPLETED: 9/6/06 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit prints to: new complete sets of B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo .., _., ... City of Carlsbad 06-2225 9/6/06 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 5. Please provide evidence the City of Carlsbad will permit the sump system and not required a gravity drainage system per section 709 of the Plumbing code. Per conversation with the City of Carlsbad if necessary the industrial waste may be collected and pumped but the sanitary waste must be maintained on the gravity drainage system. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In <Partnersliip witli (}overnment for <Buifaing Safety DATE: 8/17/06 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-2225 PROJECT ADDRESS: 2840 Loker Ave East SET:I PROJECT NAME: Seltzer Nutritional Technologies -TI l:J APPLICANT ~ l:J PLAN REVIEWER l:J FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [ZI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [ZI The applicant's copy of the check list has been sent to: Drum Plumbing / Kevin Drum 2550 Fortuna Way, Vista, CA 92083 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [ZI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted~/.K~~Jin Drum Telephone#: 760-598-3786 Date contacted: tft I f/Ov; (by,Jf/3) Fax #: 760-598-3780 Mail Telephone V Fax V In Person D REMARKS: (VM) . By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 8/8/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 \' City o( Carlsbad 06-2225 , 8/17/06 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 06-2225 OCCUPANCY: B/Fl JURISDICTION: City of Carlsbad USE: Manufacturing TYPE OF CONSTRUCTION: Unknown ALLOWABLE FLOOR AREA: SPRINKLERS?: Unknown REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 8/4/06 ACTUAL AREA: N / A STORIES: N/A HEIGHT: OCCUPANT LOAD: N/A DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/8/06 DATE INITIAL PLAN REVIEW COMPLETED: 8/17/06 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot · Cij:y of Carlsbad 06-2225 8/17/06 Please make all corrections c;:m the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 106.3.3. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbing/Mechanical Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC. 3. Please provide on the-plans the manufacturer's name, listing and model # of the sump tanks and pump systems. 4. Please revise the plans to show the waste lines from the ejectors to comply with section 710.4 of the plumbing code. Show an accessible backwater or swing check valve and a gate valve. 5. Please provide evidence the City of Carlsbad will permit the sump system and not required a gravity drainage system per section 709 of the Plumbing code. 6. Please provide an electrical plan showing the panel locations feeding the new pumps. Please panel schedule showing the circuits feeding the new pumps. 7. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Ci1,:y of Carlsbad 06-2225 8/17/06 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list: If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes CJ No CJ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 06-2225 8/17/06 VALUATION AND PLAN CHECK FEE · JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody PLAN CHECK NO.: 06-2225 DATE: 8/17/06 BUILDING ADDRESS: 2840 Loker Ave East BUILDING OCCUPANCY: B/Fl TYPE OF CONSTRUCTION: Unknown BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance •_ j Plan Check Fee by Ordinance Type of Review: D Complete Review D Structural Only D Repetitive Fee 3Repeats * Based on hourly rate Comments: D Other 0 Hourly 1.5j Hours * Esgil Plan Review Fee ($) $1so.ooj $144.001 Sheet 1 of 1 macvalue.doc Date: September 7, 2006 To: Building Department, City of Carlsbad RE: Seltzer Chemical · 2840 Loker Ave. Carlsbad, CA 92010 (619} 400-0120 {619) 400-0111 FAX Pursuant to Paragraph 8.6 Alterations and Additions, to that certain Standard Jndustrial Lease which you executed with H.G. Fenton Company for the premises located at 2840 Loket Ave, dated August 21, 2000, you are required to obtain the O-.vner~s prior written approval before commencing alterations at the Premises. Owner has reviewed the request submitted to H.G. Fenton Company on August 24, 2006. Tenant submitted to Owner a copy of the submitted plans for pennit and understands that the existing gravity drain waste system is being modified 'With the addition of sump systems to comply with the Encinas Water authority. Owner also understands that provisions have been made to by-pass this alteration in the future if requirements from the Encinas Water Authority change. Owner understands that to return waste system to existing c.ondition upon tenants departure, sump tanks (2) and clarifier will need to be r.emoved. Owner further ·advises Seltzer Chemical that, per paragraph 8.6, all costs for removal of the proposed alteration at the end ofthe term, or at move-out, whichever sba11 occur later, shall befue.responsibility of the tenant, \lpon Owners written request. Please feel free to contact.me should you need further information. Sincerely, ~ ~ fr!twnght Commercial .Prop (619) 400-0120 7577 Mission Valley Road, Suite 200 San Diego, CA92108 .. ' ' - i I.G. F&'\JTON Co1-wANY (619f 400-0.120 (619) 400-0111 FAX July 20, 2006 VIA Facsimile (760) 438-0336 AndU.S.Mail TO: Seltzer Cherr1ical Cindy Kitzmiller 5927 Geiger Court Carlsbad, CA 92008 Re: Alteralion to premises Dear Cindy, Pursuant to Paragraph 8.6 Alterations and Additions, to that certain Standard Industrial Lease which you executed with H.G. Fenton Company for the premises located at 2840 Loker Ave., dated August 21, 2000, you are required to obtain the Owner's prior written approval before commencing alterations at the Premises. Owner has reviewed tl1e request submitted to I-I. G. Fenton Company on July 19, 2006, a copy of which is attached hereto, and hereby approves the same. This approval, however, is conditioned upon the Tenant complying with each and every provision of the Lease. Owner :further advises Seltzer Chemical.that,· per paragraph 8.6, all costs for removal of the proposed alteration at the end of the term, or at move-out, whichever sh.all occur later, shall be the responsibility of the tenant. upon Owners written request. Please feel free to contact me if you have any questions. Sincerely, #r~4-~r~ 6---- Brenda Wright Property Manager cc: tenant file , attachments: Drum Plumbing letter, working drawings 7577 Mission Valley Road, Suite 200 San Diego, CA 92106 . .-I ,, J : CB062225 2840 LOKERAVEAST 101 : SELTZER TECH-INSTALL 2 SUMP . L .. ~~.~.~~ -~--'.?L:A~IFIER cz/,-,/ow-['sGIL CLm j7rZ!/-a--~lk/(JM~&_cyf-C¼ff{!?'/f, c~,f;.f)~r -sa:!-~~d ;t:. f---{1 -{h-Go;,,:/ Cl/7/ 1/;3/M Jf.,n/AJ rf'(tUIA-@Fc. q )l 3 /Db ( ff LTS'.{) \ __