HomeMy WebLinkAbout2846 RANCHO RIO CHICO; ; CB052672; Permit/ City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-23-2005' Residential Permit Permit No: CB052672
Building Inspection Request Line (760) 602-2725
Job Address: 2846 RANCHO RIO CHICO CBAD
Permit Type: RESDNTL Sub Type: RAD Status: ISSUED
Parcel No: 2226120600 Lot #: 0 Applied: 07/20/2005
Valuation: $45,540.00 Construction Type: NEW Entered By: SB
Occupancy Group: Reference #: Plan Approved: 08/23/2005
# Dwelling Units: 0 Structure Type: ( Issued: 08/23/2005
Bedrooms: 0 Bathrooms: 0 Inspect Area:
,roject Title; O'BRIEN RES 414 SF MASTER Orig PC#:
ED AND BATHROOM Plan Check#:
Owner:
lEN THOMAS OBRIEN THOMAS B&KATHY
2846 RANCHO 2846 RANCHO RIO CHICO
CARLSBAD CA CARLSBAD CA 92009
Building Permit $331.95 Meter Size
Add'I Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00
Plan Check $215.77 Meter Fee $0.00
Add'l Plan Check Fee $0.00 SDCWA Fee $0.00
Plan Check Discount $0.00 CFD Payoff Fee $0.00
Strong Motion Fee $4.55 PFF (3105540) $0.00
Park in Lieu Fee $0.00 PFF (4305540) $0.00
Park Fee $0.00 License Tax (3104193) $0.00
LFM Fee $0.00 License Tax (4304193) $0.00
Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00
Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL $55.00
Renewal Fee $0.00 ELECTRICAL TOTAL $20.00
Add'l Renewal Fee $0.00 MECHANICAL TOTAL $24.00
Other Building Fee $0.00 Housing Impact Fee $0.00
Pot. Water Con. Fee $0.00 Housing InLieu Fee $0.00
Meter Size Housing Credit Fee $0.00
Add'l Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00
Red. Water Con. Fee $0.00 Sewer Fee $0.00
Additional Fees $0.00
TOTAL PERMIT FEES $651.27
Total Fees: $651.27 Total Payments To Date: $215.77 Balance Due: $435.50
COP 435-50
FINALCVPERDY&!~
Insnetnr: Clearance: Date:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
J\
PERMIT APPLICATION •
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO.CÔrz7L
EST. VAL. ? 3, Sf
Plan Ck. Deposit --7-1 5,77 —
Validated
Date '1
QC
Address #1 Business Name (at this address) 02
2L:1 0 scri ion Lot No. Subdivision Name/Number
t c_1o,
Asse or's rce # Existi Use A. ftp (. Description of Work SQ T #0 Stories A
04 373 2i,v,
Unit No. Phase No. Total # of Units COP 215.77
Pr000sed Use
# dY Bedrooms # of Bathrooms
y!CANT 1ogtcg5a49
Name Address City State/Zip Teon!
PROPERTY OWNER
Name Address City State/Zip Telephone #
CONTRACTOR COMPANY NAME -.
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001).
Name Address City State/Zip Telephone #
State License # License Class City Business License #
Designer Name Address City State/Zip Telephone
State License #
6 WORKERS COMPENSATION *
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date__________________
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*1001 OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE _____ DATE ____________________
7/ OWNER BUILDEACLARATION
(hereby affirm that I am exempt from the Contractor's License Law for the following reason: or,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
GIr I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section Business and Professions Code for this reason:
1 - I personally plan to provide the major labor and materials for construction of the proposed property improvement,'ES
lhave not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): L&$
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number):
I will provide some Qf the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / pftone number / type work): (C.('1 LI P 1g' 4 (Cc C
J PROPERTY OWNER SIGNATURE (..r2A4' K) e,.
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505. 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
$ CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS_______________________________________________________
W. APLIA.pfli.c.ER.
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cite' of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0 deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commen or a period of 1 days (ection 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE ..4t#¼."cfY' DATE
WHITE: File YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg Inspection Request
tM®R For: 11/21/2005
Permit# CB052672
Title: O'BRIEN RES 414 SF MASTER
Description: BED AND BATHROOM
Type: RESDNTL Sub Type: RAD
Job Address: 2846 RANCHO RIO CHICO
Suite: Lot 0
Location:
APPLICANT OBRIEN THOMAS B&KATHY
Owner: OBRIEN THOMAS B&KATHY
Remarks:
Total Time:
Inspector Assignment: PC
Phone: 7609291213
Inspector:
Requested By: NA
Entered By: CW
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comment
Comments/Notices/Hold
Associated PCRs/CVs
Inspection History
Date Description
10/20/2005 17 Interior Lath/Drywall
10/14/2005 16 Insulation
10/12/2005 14 Frame/Steel/Bolting/Welding
10/12/2005 16 Insulation
10/12/2005 18 Exterior Lath/Drywall
10/12/2005 24 Rough/Topout
10/12/2005 34 Rough Electric
10/12/2005 44 Rough/Ducts/Dampers
09/16/2005 14 Frame/Steel/Bolting/Welding
09/16/2005 83 Roof Sheathing/Ext Shear
08/25/2005 11 Ftg/Foundation/Piers
08/24/2005 21 Underground/Under Floor
06/24/2005 22 Sewer/Water Service
Act lnsp Comments
AP PC
AP PC
AP PC
WC PC
AP PC 1) will recall shower pan insp 2) roof not loaded but no mt shear or transf.
AP PC
AP PC
AP PC
CA PD
AP PD
AP PC
AP PC
AP PC
EsGil Corporation
In (Partnership with government for Bui(iing Safety
DATE: August 18, 2005 0 APPLICANT
JURIS.
JURISDICTION: Carlsbad PLAN REVIEWER
U FILE
PLAN CHECK NO.: CB052672 SET: II
PROJECT ADDRESS: 2846 Rancho Rio Chico
PROJECT NAME: Addition for the O'Brien Residence
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
LII The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LIII The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
LII The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
Lii The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Li Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #: S.A.A
Mail Telephone Fax In Person
REMARKS: Please .add note in red on sheet A-I oh 2nd set.
By: Steve Sanders Enclosures:
Esgil Corporation
E GA 0 MB 0 EJ El PC 8/11/05 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
EsGil Corporation
In Partners/iip with government for Q3ui(&ng Safety
DATE: July 27, 2005
JURISDICTION: Carlsbad
PLAN CHECK NO.: CB052672 SET: I
PROJECT ADDRESS: 2846 Rancho Rio Chico
PROJECT NAME: Addition for the O'Brien Residence
APPLICANT
J PLAN REVIEWER
IJ FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
LII The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Frank Astorga
3845 Linda Vista Dr. San Marcos, CA 92069
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Frank Astorga (. '-4) Telephone #: (760) 597-0780
Date contacted:)? fO5(by: ) Fax #: None Provided
Mail c_FeIephone ' Fax In Person
LI REMARKS:
By: Steve Sanders Enclosures:
Esgil Corporation
U GA U MB fl EJ 0 PC 7/21/05 tmsmti.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
Carlsbad CB052672
July 27, 2005
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: CB052672 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2846 Rancho Rio Chico
FLOOR AREA: Addition 414sf STORIES: 1
HEIGHT: 16' Approx.
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 7/20/05
DATE INITIAL PLAN REVIEW
COMPLETED: July 27, 2005
FOREWORD (PLEASE READ):
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 7/21/05
PLAN REVIEWER: Steve Sanders
This plan review is limited, to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the.disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections•
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 2001 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CB052672
July 27, 2005
Please make all corrections on the original tracings, as requested in the correction list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in
one of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602-
2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning,
Engineering and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver
all remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by EsGil
Corporation is complete.
MECHANICAL (UNIFORM MECHANICAL CODE)
Specify on the plans the following information for the fireplace(s), per Section
106.3.3:
Manufacturer's name.
Model name/number.
ICBO approval number, or equal.
Please clarify if the Pre-Fabricated fireplace is a direct vent fireplace. Why
is a chimney chase shown if the fireplace is a direct vent appliance? Is it
possible the extended direct vent duct shown is providing combustion air?
If so please change nomenclature to specify combustion air. If the
extended duct is a direct vent please provide documentation from the
manufacturer detailing the installation of the vent and provide details on
the plans for the direct vent installation.
Carlsbad CB052672
July 27, 2005
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this
correction list? Please indicate:
Yes 13 No U
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of•
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Steve Sanders at
Esgil Corporation. Thank you.
Carlsbad CB052672
July 271 2005
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: CB052672
PREPARED BY: Steve Sanders DATE: July 27, 2005
BUILDING ADDRESS: 2846 Rancho Rio Chico
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Addition 414 City Est. 45,540
Air Conditioning
Fire Sprinklers
TOTAL VALUE 45,540
Jurisdiction Code Icb 113y ordinance I
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review: E Complete Review
I $331.951
I $215.771
LI Structural Only
I $185.891
LI Other
____________ ElRepetitive Fee IRepeats El Hourly . Hour *
Esgil Plan Review Fee
Comments:
Sheet I .of I
macvatue.doc
0c
City of Carlsbad
BUILDING PLANCHECK CHECKLIST
DATE: PLANCHECK NO.: CB
BUILDING A'DDRSS: OWY& R-L r-D
PROJECT DESCRIPTION: QJç()
ASSESSOR'S PARCEL NUMBER: 292 ,f& - EST. VALUE:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please see the attached report of deficiencies
marked with 0. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
By: Date:
By: Date:
By: Date:
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT:
Dedication Application
El Dedication Checklist
El Improvement Application
O Improvement Checklist
El Future Improvement Agreement
U Grading Permit Application
ENGINEERING DEPT. CONTACT PERSON
Name: JOANNE JUCHNIEWICZ
City of Carlsbad
Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Phone: (760) 602-2775
CFD INFORMATION
Parcel Map No:
Grading Submittal Checklist Lots:
El Right-of-Way Permit Application Recordation:
O Right-of-Way Permit Submittal Checklist Carlsbad Tract:
and Information Sheet
Sewer Fee Information Sheet
Carlsbad, CA 9200817314 • (760) 602-2720. FAX (760) 602-!&° ®
c0-c'
BUILDING PLANCHECK CHECKLIST Al
/ VAAOL SITE PLAN
II 1S 2' 3RD.
0 0 1. Provide a fully dimensioned site plan drawn to scale. Show:
North Arrow F. Right-of-Way Width & Adjacent Streets
Existing & Proposed Structures G. Driveway widths
Existing Street Improvements H. Existing or proposed sewer lateral
/ D. Property Lines I. Existing or proposed water service
E. Easements J. Existing or proposed irrigation service
0 E 2. Show on site plan:
( A. Drainage Patterns
Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
Existing & Proposed Slopes and Topography
Size, type, location, alignment of existing or proposed sewer and water service (s)
that serves the project. Each unit requires a separate service, however, second
dwelling units and apartment complexes are an exception.
/ D. Sewer and water laterals should not be located within proposed driveways, per
/ standards.
0 0 3. Include on title sheet:
Site address
Assessor's Parcel Number
Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
F:8UILDING PLANCHECK CKLST FORM.dOc 2 Rev. 7I14100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE
0 El 4a. Project does not comply with the following Engineering Conditions of approval for
ProjectNo.______________________________________________
1=1 El 0 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
U 0 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
( drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ 15.276 , pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 M" x 11" plat map and
submit with a title report. All easement documents must be approved and signed
by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
/
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
121' El El 6a. All needed public improvements upon and adjacent to the building site must be
/ constructed at time of building construction whenever the value of the
f construction exceeds $_76.380 , pursuant to Carlsbad Municipal Code Section
.18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
eheek-pr-ocess-The-completed-application-fecm-and-the-requicements-on-the
F:BUILDtNG PLANCHECK CKLST PORM.doc . - 3 .
Rev. 7114/00
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
El El El 6b. Construction of the public improvements may be deferred, pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of _$0.. so we may
prepare the necessary Neighborhood Improvement Agreement. This agreement
must be signed, notarized, and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
El 12 El 6c. Enclosed please find, your Neighborhood Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Neighborhood Improvement
Agreement completed by:
Date:
El El El 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
15.16.010 of the Municipal Code.
El 0 El 7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import,
export and remedial). This information must be included on the plans.
12 0 0 7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date:
0. El El 7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
F:BUILDING PLANCHECKCKLST FORM.doc 4 , Rev. 7114100
BUILDING PLANCHECK CHECKLIST
ST ND 2 3RD
El El 7d.No Grading Permit required.
El El El 7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
Ok [:] 0 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or 71 private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-of-Way permit required for:
9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
10. NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive, areas. Plans for such improvements shall be approved by
the City prineer prior to issuance of grading or building permit, whichever
occurs W.
11. equired fees are attached
rNo fees required
WATER METER REVIEW
ILV 0 0 12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
0-v-ersiz—e-d-note-m-a-re-ln=-uml-e-durMg-tow--fl-ow-con-ditiom.—If-iri~-oversizud,- for
the life of the meter, the City will not accurately bill the owner for the water used.
All single family dwelling units received "standard" 1" service with 5/8" service.
F:BUILOING PLANCHECK CKLST FORM.doc Rev. 7/14/CO
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
Maximum service and meter size is a 2" service with a 2" meter.
If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand. (manifolds are considered on case by case basis to limit
multiple trenching into the street).
0 0 12b. Irrigation Use (where recycled water is not available) r All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I",
and potable water is typically a circled "W'. The irrigation service should
look like:
__J .-... STA 1+00 Install 2" service and
'-' 1.5: meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
Hydraulic grade line
Elevation at point of connection (POC)
Pressure at POC in pounds per square inch (PSI)
Worse case zone (largest, farthest away from valve
Total Sprinkler heads listed (with gpm use per head)
Include a 10% residual pressure at point of connection
3. In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
F:BUIl.DlNG PL.ANCHECK CKLST FORN.doc 6 Rev. 7/14100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future.
01 U D 12c. Irrigation Use (where recycled water is available)
Recycled water meters are sized the same as the irrigation meter above.
If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, .this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. . If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
U U U 13. Additional Comments:
F:BUILDNG PLANCHECK CKLST FORM.dOC 7 Rev. 7114100
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Ch4 No. CB O 2 t' ? 1- Address_P4Nc# 0 p-jO (AID
Planner_J V( (V 1- O Phone(760)602
AN. 2-2-2- 2[7—O, I Type of Project & use:f' ft() Net Project Density: N/A DU/AC I zoning:J (- General Plan: I2-tJVl Facilities Management Zone:
-
1 CFD (In/out) #_Date of.participation: Remaining net dev acres
3!
. (For non-residential development Type of land used created by this
; CII'CIIOflI permit__________________________________________
LeaendL Item Complete' .fl Item Incomplete - Needs your action•
0 0 Environmental Review Required: YES NO__— TYPE_________
DATE OF COMPLETION: -
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
0 0 Discretionary Action Required: YES____ NO TYPE_________
APPROVALJRESO. NO. DATE_____
PROJECT NO.___________________
OTHER RELATED CASES:__________________________________
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:_______________________________________________________
0 0 . Coastal Zone Assessment/Compliance
Project site located In Coastal Zone? YES____ NO____
CA Coastal Commission Authority? YES___ NO___
If California Coastal Commission Authority: Contact them at —.7575 Metropolitan Drive, Suite 103,
San Dlego.CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES____ No____
if NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Follow-Up Actions:
Stamp BUilding Plans as 'Exempt or 'Coastal Permit Required' (at m!nimumFloor Plans).
Complete Coastal Permit Determination Log as needed.
Incluslonary Housing Fee required: YES____ NO _
(Effectivedate of Inclusionary Housing Ordinance - May 21, 1993i)
Data Entry Completed? YES___ NO
(NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN,
Enter Fee, UPDATEI)
Site Plan:
KMDMW1,eOUNTERBId91PIncNcR.vct*Iut
1,. Provide a fully dimensional site plan drawn to scale.
S
h
o
w
:
.
N
o
r
t
h
a
r
r
o
w
,
p
r
o
p
e
r
t
y
l
i
n
e
s
,
easements, existing and proposed structures, streets, existing stree
t
i
m
p
r
o
v
e
m
e
n
t
s
,
r
i
g
h
t
-
o
f
-
w
a
y
width, dimensional setbacks and existing topographical lines (i
n
c
l
u
d
i
n
g
a
l
l
s
i
d
e
a
n
d
r
e
a
r
y
a
r
d
slopes). .
2. Provide legal description of property and assessor's parcel num
b
e
r
.
Policy 44 Neighborhood Architectural Design Guidelines
) 0 0 1. Applicability. YES-N0-
3 0 0 2. Project complies YES NO_______
Zoning: •.
JOD 1. Setbacks:
Front. . Required Z.o Shown
interior Side: Required_. Shown_______________
Street Side:. Required Shown
Rear. Required _lf!fr" Shown______________
Top of slope: Required Shown______
0 0 2. Accessory structure setbacks:
Front Required Shown_____________
Interior Side: Required Shown_____________
Street Side: Required Shown_____________
Rear. .
Required Shown_____________
Structure separation: Required Shown
1
4 0 0 3. Lot Coverage: Required__________ Shown 4
0 0 4. Height Required_? Shown____________
0 0 5. Parking: Spaces Required shown 57
(breakdown by uses for commercial and IndustriaIprojects req
u
i
r
e
d
)
Residential Guest Spaces Required_. Shown_____________
J 0 0 Additional Comments___________________________
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
DKTO ISSUE AND ENTERED APPROVAL INTO CQMPUTER
,4tç DATE-]~
H4ADMINOUNER8Id9PIfld*R.VNd
Raw &1