Loading...
HomeMy WebLinkAbout2875 LOKER AV EAST; CS; CB131759; Permit10-23-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No CB131759 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2875 LOKER AV EAST CBADSt C Tl 2090831000 $10,000 00 Sub Type INDUST Lot# 0 Construction Type NEW Reference # T-MOBILE - REPLACE 6 ANTENNAS BEHIND CONCEALMENT PARAPET ON CABLE TRAY Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* ISSUED 07/24/2013 SKS 10/23/2013 10/23/2013 INSTALL 3-RRU22S BEHIND Applicant TIM HENION Owner TECHBILT CONSTRUCTION CORP 1264 BASSWOOD AVE CARLSBADCA 92008-1901 503-519-8591 P 0 BOX 80036 SAN DIEGO CA 92138 Building Permit $126 87 Meter Size Add'l Building Permit Fee $0 00 Add'l Reel Water Con Fee $0.00 Plan Check $88 81 Meter Fee $0 00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $2 10 PFF (3105540) $0 00 Park Fee $0 00 PFF (4305540) $0 00 LFM Fee $0 00 License Tax (3104193) $0 00 Bndge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0 00 Renewal Fee $0 00 PLUMBING TOTAL $0 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $0 00 Other Building Fee $0 00 MECHANICAL TOTAL $0 00 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Reel. Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $1 00 HMP Fee Fire Expedidted Plan Review $0 00 Green Bldg Standards Plan Chk 99 TOTAL PERMIT FEES $218 78 Total Fees $218 78 ayments To Date $218 78 Balance Due: $0.00 Inspector FINAL AP Date _ Clearance NOTICE Please take NClCE thWt approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" rou have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follo«/ the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carisbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired ••f7 /'(THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE-X^ANNING ^^^1 IGINEERING BUILDING ^FIRE ] HEALTH •HAZMAT/APCD CITY OF CARLSBAD T Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www.carlsbadca.gov ^-j^s77 Plan Check No. | ^"7^^ Est. Value j^loiOOO Plan Ck. Deposit Date 1/Z^I(\ [SWPPP JOB ADDRESS too Ik 5UITE#/SPACE</UNIT# CT/PROJECT # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK- /nclude Square Feet Of Affected Areafsj _ . EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES[~~|# N0|71 AIR CONDITIONING YES I I NO PTI FIRE SPRINKLERS YES I jNOpn APPLICANT NAIVIE (Primary Contact) APPLICANTNAME (Secondary Contact) ADDRESS ADDRESS CITY STATE ZIP STATE ZIP PHONE PHONE PROPERTY OWNER NAME CONWACTOR BUS. NAME ADDRESS ADDRESS 13^v8 C»SUJ^ vdoi^lb Et^Avl CITY PHONE STATE ZIP CITY FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS CITY BUS LIC# / r- (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions ofthe Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 ofthe Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Dec(arattBn«4Aag^yaffim? under penalty of perjury one ofthe follomng declarations • I have and will maintain a certificate of consenTtlTselttnsurG for workers' compensation as provided by Section 3700 of the Labor Code, for the perfomiance of the wori< for which this pennit is issued • I have and will maintain workers' compensation, as required ov"98cton 3700 of the Labor Code, for the performancg^flf^the work for which this permit is issued My workers' compensation insurance carrier and policy number are InsuranceCo Policy No ThB section need not be completed if the permit is for one hundred dollars ($100) or less IKI Certificate of Exemption; I certify that in the perfonnance of the work for which this pennit"isTS6y|d, I shall not e?tiplSy any^rsonTnany manner so as to tJecome^subject to'ttfe V\lorl('#is''Compensation Laws of California WARNING- Failure to secure workers' compensation coverage is unlawful, and shail7t)b||Ct an employer to criminal penalties and civil fines up to one hundred thousanr addition to the cost of compensation^jianiAee-gg^Kaiided for in Section 3706 of the Labor code, interesKvid attomey's fees >£$'CONTRACTOR SlGNATUn AGENT DATE dollars (&100,000), in / hereby affirm that I am exempt from Contractor's bcense Law for the foltcming reason I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the stmcture is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale It, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) I I I, as owner of the property, am exclusively contractng with licensed contractors to constmct the proiect (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I I i am exempt under Section _ .Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement ^Yes I iNo 2 I (have / have not) signed an application for a building perniit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed constructon (inciude name address / phone / contractors' license number) 4 I plan to provide portions of the wort(, but 1 have hired the following person to cooniinate, supervise and provide the major work (include name / address / phone / contractors' license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of wori() PROPERTY OWNER SIGNATURE QAGENT DATE is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registraton form or nsk management and preventon program under Sectons 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account AcP Yes ^ Is the applicant or future building occupant required to obtain a permit from the air polluton control distict or air qua],ity management distncf • Yes • VW Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site' Yes (fe IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that ttiere is a construcfion lending agency for the performance of fhe work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I certify ttiat I have read the applicaton and state thatthe above inftinnation is correct ond that the mfbimation on the plans Is accuiate I agree to comply with aii City ordinances and State laws relatng to buiiding constnicton I hereby authonze representative of the City of Cartsbad to enter upon the above mentoned property Ibr inspecton purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CfTY OF CARLSBAD AGAINST ALL LIABILITiES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA pemiit is required for excavatons over 5'0' deep and demoliton or constmction of staidures over 3 stones in height EXPIRATION Every pemiit issued by the Building Ofifcial under the previsions of this Code shall expire by limitaton and become null and vod if the building or worl^ authorized by such permit is not commenced within 180 days from the date of such permit or if the building or «ork authonzed by such pennit is suspended or abandoned at any time after the work is commenced fbr a penod of 180 days (Section 106 4 4 Unifonn Building Ckxie) vSS"APPLICANT'S SIGNATURE . "UJLJ^^ DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. ! F I C A :y /Commerc Fax (760) 602-8560, Email buildingtajcarlsbadca gov or Mail the completed forni to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008 C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE Carlsbad CA PHONE EMAIL OCCUPANT'S BUS LIC No DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) MAILTO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) IVIAIL / FAX TO OTHER: ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ^APPLICANT'S SIGNATURE DATE •hrHEF THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE. nPLANNING IZlENGINEERiNG nBUILDING OFIRE OHEALTH •HAZMAT/APCD CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www.carlsbadca.gov Plan Check No. Est. Value Plan Ck. Deposit Date SWPPP JOB ADDRESS SUITE#/SPACE#/UNIT# APN - CT/PROJECT# LOT* PHASE# # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK: (ncfude Square Feet of Affected Area(s) EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESr~|# NOQ AIR CONDITIONING YES| |NO| 1 FIRE SPRINKLERS YES| |NO| 1 APPLICANTNAME (Primary Contact) APPLICANTNAME (Secondary Contact) ADDRESS ADDRESS CiTY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL PROPERTY OWNER NAME CONTRACTOR BUS. NAME ^ , ADDRESS ADDRESS 1 1 y CITY STATE ZIP CITY STATE A-ZIP PHONE FAX PHONE tAX EMAIL EMAIlT ARCH/DESIGNER NfME & ADDRESS STATE LIC # STATE LIC # ' CUVSS " ( /;iTYBUS LIC# (X^no-^ (Sec 70315 Business and Professions Code Any City or County wtiicti requires a permit tc construct, alter, improve, demolish or repair any structure, pnor to its issuance, also requires ttie applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Ctiapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Declaration / hereby affinn under penalty of perjury one of the following declarations tV|| I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued E^XI'sve and will maintain workers' compensation, as required by Secton 3700 of the Labor Code, for the performance of the work for which this permit is issued My workers' compensaton.insurance carrier and policy number are InsuranceCo '/f t r-f«^priX U\A(jb f UOr^-V^rT:, Policy No "1"Xl^ ^ Expiration Date J_0|^i|U-( This section need not be completed if the permit is for one hundred dollars ($100) or less I I Certificate of Exemption; 1 certify that in the perfomiance of the work for which this pennit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensaton Laws of California WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 ofthe Labor code, interest and attomey's fees ^ CONTRACTOR SIGNATURE (3;AGE •AGENT DATE 10 kill WJ7} j}-stM.^m / fiereiiy affirm that I am exempt from Contractor's License Law for the following reason I I I, as owner of the property or my employees with wages as their sole compensaton, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of pniperty who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completon, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) I I I, as owner of the property, am exclusively contractng with licensed contractors fo construct the project (Sec 7044, Business and Professions Code The Contractor's Ucense Law does not apply to an owner of properly who buiids or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I I I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for constructon of the proposed property improvement [HjYes I iNo 2 i (have / have not) signed an application for a building permit for the proposed work 3 1 have confacted with the following person (fimi) to provide the pnjposed constructon (inciude name address / phone / contractors' license number) 4 1 plan to provide portions of the work but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number) 5 i wiii provide some of the work, but i have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of wori<) ^1 PROPERTY OWNER SIGNATURE QAGENT DATE Inspection List Permits: CB131759 Type: Tl INDUST T-MOBILE - REPLACE 6 ANTENNAS BEHIND CONCEALMENT. INS Date Inspection Item Inspector Act Comments 01/07/2014 19 Final Structural - Rl 01/07/2014 19 Final Structural PY AP Friday, January 10, 2014 Page 1 of 1 J K & J Incorporated 13948 Calle Bueno Ganar Jamul, CA 91935 October 28,2013 City Of Carlsbad - Development Services Permits 1635 Faraday Ave Carlsbad, CA 92008 RE: T-Mobile Site ID SD06377- Building Peimit Number CBl31759 To whom it may concem: Please accept this letter as authorization for a change of Contractor from JK&J Incorporated to a contractor of T-Mobile's (Applicant) selection for City of Carlsbad Permit Number CB 131759. Should you have any questions please feel free to contact me at 619-520-0580. Sincerely, J. David Gardner, Jr. CEO JK&J Incorporated EsGil Corporation In (PartnersHip witH government for (BuiCding Safety DATE: 8/6/2013 • APPLICANT ^ JURIS JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-1759 SET I PROJECT ADDRESS: 2875 East Loker Avenue PROJECT NAME: T-Mobile SD06377A-CARLSBAD XI The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By: David Yao Enclosures: EsGil Corporation • GA • EJ • PC 7/29 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 .City of Carlsbad 13-1759 8/6/2013 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 13-1759 PREPARED BY: David Yao DATE: 8/6/2013 BUILDING ADDRESS: 2875 East Loker Avenue BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq FL) Valuation Multiplier Reg Mod VALUE ($) cell site revision per city 10,000 Air Conditioning Fire Spnnklers TOTAL VALUE 10,000 Jurisdiction Code cb By Ordinance Bldg Permit Fee by Ordinance Plan Ctieck Fee by Ordinance Type of Review I I Repetitive Fee Repeats [Zl Complete Review • Other j—J Hourly EsGil Fee • Structural Only Hr @ * $126.87 $82.47 $71.05 Comments Sheet 1 of 1 macvalue doc + 4 CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 FaradayAvenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 8/12/13 PROJECT NAME:T-Mobile | SD06377A Carlsbad OaksPROJECT ID: PLAN CHECK NO: CBl31759 SET#:I ADDRESS: 2875 Loker Avenue East APN: 209-083-10 VALUATION: $10,000 APPLICANT CONTACT: thenion@deprattiinc.eom This plan check review transmittal is to notify you of clearance by: LAND DEVELOPIVIENT ENGINEERING DIVISION Final Inspection by the Construction & Inspection Division is required: Yes L J /Vo iXj ^§ For status from a division not marked below, please call 760-602-2719 This plan check review is NOT COIVIPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. t'/ y-' '760-602-4610..;:I 7^''''^. ! LAND bEVEI,6PI\liNT ENGS i,V'' 76()^0^-2750^i j^,^^I' t;;^' j{FI#''PREVENf JON/^^ j w .• 77&P:Q02^^Q65^'-^J'^7^. i.' [ Chris Sexton I ' 760-602-4624 [ Chris.Sextori(g''caiisbaclca.gov j ! Kathleen Lawrence L : 760-602-2741 Kathleen.Lawrence@carlsbadca.gov y-. Greg Ryan \ L„-J 760-602-4663 [, Gregory.Ryan@carlsbadca.gov f ; : Gi..-; ."'uiz I - - 760-602-467.5 ! Gina.Piuiz@carlsbadca.gov | \/ Linaa ontiveros ; /\ 760-602-2773 1 Linda.Ontiveros@carlsbadca.gov '' 1"^"] Cindy Wong ; L^J 760-602-4662 J Cynthia Wong@carlsbadca.gov ' i" ~1 1 1 r"^^^" Dominic Fieri L_J 760-602-4664 ; Dominic.Fien@carlsbadca.gov ; Remarks CARLSBAD CITY OF PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 FaradayAvenue (760) 602-4610 www carlsbadca.eov DATE: 7/29/13 PROJECT NAME: Techbilt WCF PROJECT ID: IVICUP 10-28 PLAN CHECK NO: CB 13-1759 SET#: n/a ADDRESS: 2875 Loker Ave E APN: 209-033-10-00 ^ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Garcia A Final Inspection by the Planning Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed beiow. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should inciude corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: For questions or clarifications on tlie attactied cliecklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Chris Sexton 760-602-4624 Chris.S6xton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.fiov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1 1 Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov X Chris Garcia 760-602-4622 Chris.Garcia@carlsbadca.gov • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: Replacing antennas behind the existing RF screens is consistent with approved IVICUP 10-28. No amendment to the IVICUP required. 4 CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Comi0|^& Economic Development Department 1635 FaradayAvenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 07/31/2013 PROJECT NAIVIE: T-MOBILE PLAN CHECK NO: 1SET#:1 ADDRESS: 2875 LOKER AVE EAST PROJECT ID: CB131759 APN: 209-033-10 • This plan check review is complete and has been APPROVED by the FIRE Division. By: GR A Final Inspection by the FIRE Division is required • Yes ^ No This plan check review is NOT COIVIPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from ail divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING 760-602-4610 766-|j2g750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov X Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1 1 Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: APPROVED, SEE ATTACHED Carlsbad Fire Department Plan Review Date ofReport: Requirements Category: TI, INDUST 07-31-2013 Reviewed by: Name: Address: TIM HENION 1264 BASSWOOD AVE CARLSBAD CA 92008-1901 Permit #: CB131759 Job Name: Job Address: T-MOBILE - REPLACE 6 2875 LOKER AV EAST CBAD St: C Please review carefully all comments attached. Conditions: CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 07/31/2013 By: GR Action: AP DCl PACIFIC ^IHjC WORKS STRUCTURAL CALCULATIONS Antenna Modernization T-MOBILE CARLSBAD OAKS SD06377A 2875 E. Loker Avenue Carlsbad, CA 92011 Revision: 0 7/23/2013 This structural calculation relates only to the telecom facility for which they were prepared. The use of this report for another project is strictly prohibited. Data were based on information provided to DCl PACIFIC as listed in this set of calculation; DCl PACIFIC is not responsible for the accuracy of infonnation provided by outside sources. ARCHITECTURE | ENGINEERING j CONSULTING 32 Executive Park j Suite 110 | Irvine | CA 92614 | T 949 475 1000 | 949 475 1001 F DCl PACIFIC ^|E|C WORKS STRUCTURAL CALCULATIONS SD06377A Project: T-MOBILE Site Name: CARLSBAD OAKS Site Number SD06377A Rev: Subject- Structural Analysis for Antenna and Equipment Modernization FAI Project Address: 2875 E. Loker Avenue Carlsbad, CA Zip Code: 92011 Design Criteria: Seismic Ss = 1.251 Occupancy Cat. il S1 = 0.472 Seismic Design Cat. D Fa = 1.000 Soil Site Class D Fv = 1.528 Seismic Factors based on Zip Code (USGS Earthquake Ground Motion Parameter): Ss = 1.251 g S1 = 0.472 g SMS 1.251 g SDS = 0.834 g SM1 0.721 g SDI = 0.481 g Wind Basic Wind Speed = Exposure = Occupancy Category = Design Codes and References 2010 CALIFORNIA BUILDING CODE 2009 INTERNATIONAL BUILDING CODE AISC 13TH ED. ASCE/SEI - 7-05 ACI 318 Steel: Structural = Pipe Tube Steel = Bolts 90 C II IVIPH Masonry: Concrete: Wood: Module fm Type fc Sawn GluLam ASTM A36 (Angles, Plates, Channels and Misc.) ASTM A572 (WF Beams) ASTM A53 - Grade B ASTM A500 ASTM A307 (Fasteners) Grade - 'N' 1,500 psi 2500psi @ 28days UNO DF-Larch #1 24F-V4, V5, V8 Fy=36ksi Fy=50ksi Fy=35ksi Fy=40ksi Ft=20ksi Rev. Reason for Revision By Checked Approved Date Issued for Submittal NOC BOK DKD 7/23/2013 Record or Revisions ARCHITECTURE | ENGINEERING | CONSULTING 32 Executive Park | Suite 110 | Irvine | CA 92614 | T 949475 1000 | 949 475 1001 F DCl PACIFIC /%|E|C WORKS Project: T-MOBILE Site Name: CARLSBAD OAKS Site Number SD06377A Rev: 0 PROJECT INFORMATION Documents Provided for Reference: 1.0 Construction Drawings prepared by "DCl PACIFIC 2.0 3.0 4.0 5.0 Scope of Work: Purpose: Replacement of existing panel antennas with new 'Ericsson' AIR21 Panel Antennas, utilize existing mounting hardwares. The purpose of this Calculation is to investigate if the existing antenna infrastructure may be able to accommodate the antenna replacement. Calculations shall be based on available documents provided and best professional judgement Conclusion: The Structural Calculation justifies structural adequacy. It is determined that the existing installation and antenna support infrastructure has sufficient allowable capacities to accommodate this modernization project. ARCHITECTURE j ENGINEERING I CONSULTING 32 Executive Park | Suite 110 | Irvine | CA 92614 | T 949 475.1000 | 949 475 1001 F DCl PACIFIC AjEjC WORKS Project: T-MOBILE Site Name: CARLSBAD OAKS Site Number SD06377A Rev: LATERAL FORCE ANALYSIS Seismic / Earthquake Load (WIectianical and Electrical Component) Zip Code = 92011 Soil Site Class = D (1613.5.2, 2010 CBC) Occupancy Cat. = II (Table 1604.5, 2010 CBC) Seismic Cat. = D (Table 1613.5.6(1) and (2), 2010 CBC) Spectral Response Accelerations: Si 0.472 g (SEISMIC Parameter) SMS = 1.251 g (SEISMIC Parameter) SMI = 0.721 g (SEISMIC Parameter) SDS = 2/3 SMS = 0.834 g (Eq. 16-39, 2010 CBC) SDI = 2/3 SMI = 0.481 g (Eq. 16-40, 2010 CBC) Equivalent Lateral Force Procedure (Section 12.8, ASCE 7-05) Fp = [(0.4) ap SDS Wp / (Rp/lp)] (1 +2(z/h)) (Equation 13.3-1) Where (per ASCE 7-05): Fp = Seismic Design Force SDS = Spectral Acceleration, short period, Section 11.4.4 = ap = Component amplification factor, Table 13.5-1 or 13.6-1 = Ip = Component importance factor, Section 13.1.3) = Rp = Component response modification factor. Table 13.5-1 or 13.6-1 = z/h = height in structure of point of attachment over ave. roof height = Fp = 0.400 Wp 0.834 1.000 1.000 2.500 1.000 FpMAX = 1.6 SDS Ip Wp FpMIN = 0.3 SDS Ip Wp 1.33 Wp OK 0.25 Wp OK (Equation 13.3-2) (Equation 13.3-3) VULT = VASD = 0.400 0.286 Wp Wp Wind Load Basic Wind Speed Occupancy Cat. 90 mph EXPOSURE HEIGHT 100 Design Wind Loads on Otiier Structures F = qhGCfA,(lb) (N) Where (per ASCE 7-05): qh = Velocity pressure evaluated at height h per Section 6.5.6.3 FT (Secf/on 6.5.15, ASCE 7-05) = 0.00256 Kz Kzt Kn I (Ih/sf^ qz G = Cf: F = Kz = 0.85 Kzt = 1.00 Kd = 0.9 V = 90.00 lw = 1.00 -15.86 = n+Ki K2K3r (Equation 6-15) (Table 6-3) (Section 6.5.7.2) (Table 6-4) Gust Effect Factor from Section 6.5.8 = • net force coefficient from Figure 6-21 = 18.88 psf 0.85 1.40 ARCHITECTURE j ENGINEERING j CONSULTING 32 Executive Park | Suite 110 | Irvine 1 CA 92614 | T 949 475 1000 | 949 475 1001 F DCl PACIFIC A|E|C WORKS Project: T-IVIOBILE Site Name: CARLSBAD OAKS Site Number SD06377A Rev: ANTENNA LOAD CALCULATION New Antenna Specification: Manufacturer = Ericsson Model Number = AIR21 Height A = 54.0 in. Width B = 12.0 in. Depth C = 8.0 in. Anchor Spacing D = 40.0 in. Weight = 80.0 Ibs. Manufacturer's infomiation: a) Entire assembly designed to withstand 93mph wind b) Prefab Pipe Clamp adapter available from 2" to 4-1/2" Seismic Design V Wp V Wind Design V A V 0.29 x Wp 80.00 Ibs 22.88 Ibs 18.88 X A 4.50 SQFT 84.95 Ibs 153 JiL. Wind Governs ARCHITECTURE | ENGINEERING | CONSULTING 32 Executive Park | Suite 110 | Irvine | CA 92614 | T 949 475 1000 | 949 475 1001 F DCl PACIFIC A|E|C WORKS Project: T-IVIOBILE Site Name: CARLSBAD OAKS Site Number SD06377A Rev: Weight of Antenna Maximum Lateral Load Type of pipe Size of pipe ANTENNA PIPE MAST 80.00 Ibs say 200 Ibs. worst case 84.95 Ibs say 500 Ibs. worst case Standard worst case 1.50 in worst case Steel Beam B<ERCALC,INC l683-;il11.BilMailfti;.VB-ei12ft12 | 1 Lie, # : KW-0B007253 I 1 ,, Licensee; DCl PACIFIC Descripbon Investigate 1-1/2'dia std steel pipe for Antenna Loading CODE REFERENCES Calculations per AISC 360-05, IBC 2009, CBC 2010, ASCE 7-05 Load Combination Set 2006 IBC & ASCE 7-05 Material Properties Analysis Method Allow/able Stress Design Beam Bracing Completely Unbraced Bending Axis Major Axis Bending Load Combination 2006 IBC & ASCE 7-05 Fy Steel Yield E Modulus 50 0 ksi 29,000 0 ksi W(0 25) W(0 25) Span = 5 0 ft Pipe1-1/2 Std Applied Loads Load(s) for Span Number 1 Point Load W = 0 250 k @ 0 8350 ft, (Top Bracket) Point Load W = 0 250 k @ 4165 fl, (Bottom Bracket) Moment D = 0 50 k-ft, Loc = 0 B350 ft in span, (due to antenna weigtit @ top) Moment D = 0 50 k-ft, Loc = 4 165 ft in span, (due to antenna weight at bottom) DESIGN SUMMARY Sen/ice loads entered Load Factors will tie applied for calculations Maximum Bending Stress Ratio = Section used for ttiis span Mu Applied Mn/Omega Altowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Dovmviiard L-i-Lr+S Deflection Max Upward L-i-Lr+S Deflection Max Downward Total Deflection Max Upward Total Deflection 0.513 1 Plpe1-1/2 Std 0 539 k-ft 1 050 k-ft tO+W+H 0 850ft Span # 1 Maximum Shear Stress Ratio = Section used for this span Vu Applied Vn/Omega Allowable Load Combination Location of maximum on span Span # where maximum occurs 0.067 1 Plpe1-1/2 std 0 450 k 6 737 k +D+W-^H 4175 fl Span # 1 0 000 in Ratto = 0 000 in Ratio = 0 137 in Ratio = -0 021 in Ratio = 0<360 0 <360 437 2826 Maximum Forces & Stresses for Load Combinations Load Combination Segment Length Max Stress Ratios Summary of Moment Values Summaiy of Shear Values Span# +0 Dsgn L = 5 00 ft •K)*W-+I Dsgn L = S 00 It +D-K1 750LrtO 750L-K) 750W-tH Dsgn L = 5 0011 •tO-H) 750L-tO 750S-K) 750W-+I Dsgn L= 5 00« •tOeOD+W-iH Dsgn L = 5 00 ll Overall Maximum Deflections - Unfactored Loads M V Mmax + Mnax-^-Max Mnx Mix/Omega Cb Rm VaMax Vnx Vnx/Omega 0 314 0 030 033 -0 33 033 1 75 105 1 77 1 00 0 20 11 25 674 0 513 0 067 0 64 -012 054 175 105 183 100 045 11 25 674 0 463 0 058 049 -017 049 175 105 182 1 00 0 39 11 25 6 74 0 463 0 058 049 -017 0 49 175 1 05 1 82 1 00 039 11 25 674 0 387 0 055 041 0 41 175 105 164 1 00 0 37 11 25 6 74 Load Combination Span Max '-" Defl Location in Span Load Combination Max Defl Location in Span D-fW 1 0 1373 1 975 Maximum Deflections for Load Combinations - Unfactored Loads Load Combination Span Max Downward Defl Location in Span OOOOO OOOO Max Upward Del) Location in Span DOnly WOnly 0 0224 01288 01373 1 350 2525 1975 -0 0212 OOOOO OOOOO 3675 OOOO OOOO ARCHITECTURE | ENGINEERING | CONSULTING 32 Executive Park | Suite 110 | Irvine | CA 92614 | T 949 475 1000 | 949 475 1001 F DCl PACIFIC ^|E|C WORKS Project: T-MOBILE Site Name: CARLSBAD OAKS Site Number SD06377A Rev: ANTENNA PIPE MAST (cont.) steel Beam Lie. # : KW-08007253 Descnption Investigate 1-1/2'dia std steel pipe fbr Antenna Loading ENERCALC, INC 1983-2011, BuM612&12, VerS 12612 Licensee : DCl PACIFIC Vertical Reactions - Unfactored Load Combinabon Support 1 Support 2 Support notation Far left is #1 Values in KIPS Overall MAXimum DOnly WOnly D-tW Steel Section Properties Depth = Diameter = Wall Thick Area = Weight 0 250 -0 200 0 250 0 050 Pipe1-1/2Std 1 900 in 1 900 in 0 145 in 0 750 in"2 2 720 plf 0 450 0 200 0 250 0 450 Ixx Sxx Rxx Zx lyy Syy Ryy 0 29 in"4 0 31 in«3 0 626 m 0 421 in*3 0 293 in"4 0 309 in«3 0 626 in 0 586 in"4 Ycg 0 950 in Distance (ft) • +D • +D+W-I-H • *0*0 rSaL'+D + D 7S0W + H • *0*a 7£DL + It + 0 7&DW-.H • *ti fiDO+W-l- Distance (ft) • DO.Iy • WO.Iy m D+W ARCHITECTURE 1 ENGINEERING j CONSULTING 32 Executive Park | Suite 110 | Irvine | CA 92614 | T 949 475 1000 | 949 475 1001 F DCl PACIFIC ^lEK WORKS Project: Site Name: Site Number Rev: T-MOBILE CARLSBAD OAKS SD06377A 0 ANTENNA ANCHORAGE (Ericsson AIR21) Vseismic = 22.88 Ibs Vwind = 84.95 Ibs Antenna Weight = 80.00 Ibs Misc Weight (max) = 20.00 Ibs Case 1 (Dead Load) Weight = 100.00 Ibs Number of Bolts = 4.00 pes Shear per Bolt = 25.00 Ibs Case 2 (Dead + Wind Load) Weight = 100.00 Ibs Wind Force = 84.95 Ibs Total Shear -184.95 Ibs Number of Bolts = 4.00 pes Shear per Bolt = 46.24 Ibs Case 3 (Worst Case) Maximum perpendicular offset 1.00 ft Anchor Separation = 3.33 ft (see 'D' on antenna specifications) Moment = 241.58 ft-lbs (worst case scenario) Tension at Top Anchor = 72.47 Ibs Number of Bolt at Top Anchor = 2.00 pes Tension per Bolt 36.24 Ibs Maximum Shear per Bolt = 46.24 Ibs Maximum Tension Per Bolt = 36.24 Ibs Investigate Multiple Types of Anchors Anchor Size Embed. ICC LARR Vallow (lb) Tallow (Ib) Combined Result Hiiti KB TZ 1/2 2 in. ESR1917 25701 1260.0 1576.0 0.060 PASS Hiiti KB III 1/2 2.25 in. ESR1385 25577M 664.0 502.0 0.142 PASS A307 1/2 n/a n/a n/a 2355.0 4415.6 0.028 PASS Lag Screw 1/2 2 in. n/a n/a 520.0 350.0 0.192 PASS Sheet Metal Screw #12 n/a n/a n/a 150.0 344.0 0.414 PASS HiIti HY-150 1/2 4.5 in. ESR1967 25652M 1135.0 880.0 0.082 PASS ARCHrrECTURE | ENGINEERING j CONSULTING 32 Executive Park | Surte 110 | Irvme | CA 92614 | T 949 4751000 | 949 4751001 F 560 637 7 SAN DIEGO REGIONAL HAZARDOUS iVIATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE Business Name Business Contact Telephone # T Mobile Kirt Babcock 8,S8--!34-6139 ProjectAddress City state Zip Code APN# 2875 Locker Ave East Carisbad CA 92009-209-083-10 Mailing Address City state Zip Code Plan File# 10509 Vista Sorrento Pkwy San Diego CA 92121-CB131759 Proiect Contact DiA I Telenhoae # fog The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business \m\\ use, process, or store any of the following hazardous materials If any of the items are circled, applicant must contact the Fire Protection^^Agiency with jurisdiction priorto plan submittal. Facility's Square Footage (including proposed project): 180 Occupancy Rating: unrjiarioecl---.^ 1 Explosive or Blasting Agents 5 Organic Peroxides 9 Water Reactives <^43r-Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics " 14. Other Flealth Hazardl 3. Flammable/Combustible Liquids 7 Pyrophorics 11 Highly Toxic or Toxic Materials 15 None of These 4 Flammable Solids 8, Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must (aantact the County of San Diego Hazardous Matenalp-Division, Call (858) 505-6700 prior to the issuance of a building permit FEES ARE REQUIRED. YES NO 1. • 2 • 3 • 4. • 5 • 6 • 7. • Project Completion Date 500 Ovei'laiicl Ai/biiiufci, Suite 110 CONFt San Diego, CA 92123 • CalARP Exempt i Date Initials • CalARP Required / Date Initials • CalARP Complete I Date Initials Exped ed Date of Occupfn^^ ^ (for nev • construction or remodeling projects) Is your business listed on the reverse Side of this fonTi'(check all th at apply) p,py OMO Will your business dispose of Hazardous Substances or Medical VVE ste in any amoimt? ^ " Will your business store or handle Hazardous Substances in quantit es equal to or greater than 55 gallons, 500 pbunds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? / -ii^ ^ "TScW^/S^iH^KH<VAjtPA>- ^ Will your business use an existing or install an underground storage tar^^^ C0NF4 " Will your business store or handle Regulated Substances (CalARP)'' PHN ~ ~ Will your business use or install a Hazardous Waste Tank System (Title 22, Kfflcle "TO)'' Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons'? (California's Aboveground Petroleum Storage Act) PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit Note if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification S@'|S^'f'TB|^3I|3W3st 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or"eb?^(^iret'tRe WBSwfor more information Will the subject facility or construction activities include operations or equipment that emit or arere«Mibte a9}41l49 an air contaminanf? (See the APCD factsheet at http7/www sdapcd.orq/info/facts/permits pdf. and the list of typical equipmeWviyqiwi«| fflvAffCD permit on the reverse side of this from. Contact APCD if you have any questions) (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within I.OOgJI^tjOfrteOHterr^pyfldawJi^ (K through 12)'? (Search the California School Directory at http //www cde ca.aov/re/sd/ for public and private schfflsfe oj^'iafi^ school district) Has a survey been perfonned to detennine the presence of Asbestos Containing Matenal6y-"'-'-''NG DIVISION Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-fnable asbestos"? Will there be demolition involving the removal of a load supporting structural member"? YES NO 1 . • 2. • • 3 • 4 • H 5 • Briefly descnbe business activities' telecommunications Bnefly describe proposed project replace 6 antennas with new antennas I declare u nder penally pf perjury that to the best of my knowledge and bel e and correct Name of Owner or Authorized Agent Sign atl ner or Authonzed Agent Date ' FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION . BY DATE. EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY APCD COUNTY-HMD APCD COUNTY-HMD APCD p 0^ '"^-^^ REV!I» ®| DATS / ^7.^Hmi^^ HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division CB131759 2875 LOKER AV EAST C T-MOBILE - REPLACE 6 A M-rtZK tM A O nc:LllMr~\ r^(~»M/-^i—A I m—m-r tMt-nrAi I l€7^ sw •ISSUED •cv Approved BUILDING PLANNING ENGINEERING FIRE Expedite? Y (W^ 7/^/A AFS Checked by HazMat APCD Healtti • Forms/Fees Sent Reed Due? Encina Fire HazHealthAPCD PE&M Scnooi Sewer Stormwater Special Inspection CFD: Y LandUse By Density ImpArea FY Annex Factor PFF N Comments Date Date Date •ate Building Planning Engineering Fire Need? (OopAv^ L7\^ Done • Done • Done • Done • Done • Done