HomeMy WebLinkAbout2903 CORTE CELESTE; ; CB011991; Permit07/10/2001
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
# Dwelling Units
Bedrooms
Project Title
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No CB011991
Building Inspection Request Line (760) 602-2725
2903 CORTE CELESTE CBAD
RESDNTL
2551465100
$45,011 00
0
0
Sub Type
Lot#
Construction Type
Reference #
Structure Type
Bathrooms
RAD
0
NEW
ALDERTON - RAD 457 SF
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Ong PC#
Plan Check#
ISSUED
06/07/2001
JM
07/10/2001
07/10/2001
Applicant
ALDERTON SETH
2903 CORTE CELESTE
CARLSBAD CA 92009 92009
760-436-3435
Owner
ALDERTON SETH&TAMI
2903 CORTE CELESTE
CARLSBAD CA 92009
4161 07/10/01 0002 01 02
CGP 452.95
Total Fees $668 72 Total Payments To Date $215 77 Balance Due $452 95
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
O'ther Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$331 95 Meter Size
$0 00 Add'l Reel Water Con Fee
$21577 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$450 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 Sidewalk Fee
$0 00 PLUMBING TOTAL
$000 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Housing Impact F ee
$0 00 Housing InLieu Fee
Master Drainage Fee
$0 00 Sewer Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$7700
$2000
$1950
$000
$000
$000
$000
$000
$668 72
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
'review, set aside, void, or annul their imposition
iYou are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLV to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
Tees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECJ<_NO C/J 6/OfrT/
EST VAL [JO^l ,i(5./7Plan Ck Deposit
Validated By -^.
Date
Address (include Bldg/Suite #)Busirtess Name (at this address)
Name
3 APPLICANT
Address
^Contractor QWgenrfor Contractor -SQ Owner
City
Agenrfor Owner..
Fax #
Name
4 PROPERTY, OWNER
Address City State/Zip Telephone #
Address City State/Zip Telephone #Name
5 CONTRACTOR - COMPANYfNAME ...... '"" ........ ' ••"' ...... ''I' ;?•;;• """ m *. .. vsis;-1 "!!'" ""'*":
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or lhat he is exempt therefrom, and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500)1
55SI VJrjuWo ^ CWsh^ .A
ation of Section 7
Wyrfl/i/740
Name
State hcense # &'51O'Z~3)(-(
Address
License Class P I
City State/Zip
City Business License # I
Telephone #
Designer Name Address City State/Zip Telephone
State License # _
6 ..WbR'KERS'-'CdMPENSAfibNt:--. : ' • ^l: ' • .. 1°; V Jf"' ' ""ill: ' • .' : -^'^
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code for the performance
of the work for which this permit is issued
n I have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance carrier and policy number are
Insurance Company _ Policy No __ Expiration Date _
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS)
GKCERT1FICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollai£j&LQO.OOO) in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code interest and attorney s fees
SIGNATURE I HX-(^ Y\/\fjJ^- ,_ - _ DATE *1 ~ I Q " Q I _
jTp 'OWNER-BUILDER DECLARATION " :: If yN! •","", • ' . : .:|ll ••=••:
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does
such work himself or through his own employees provided that such improvements are not intended or offered for sale If, however, the building or improvement is
sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
|~| I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor s License Law does not apply to an owner of property who builds or improves thereon, Eind contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law)
l~l I am exempt under Section _ Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES I~|NO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number) __
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work) _ _
PROPERTY OWNER SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMJTS ONLY „ „.,. s: S*MN":;C rti I;: i k
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? l~l YES d NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' d YES d NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' d YES d NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DIS1 RICT
8 CONSTRUCTION LENDING AGENCY i - : ii
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code)
LENDER'S NAME ^/ f^- LENDER S ADDRESS
:9 '^liPPLICANTCERtlFICAfiON" ' """' " if "*" ' " "y . .-k*W • :'':'" ;,.. •
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code)
APPLICANT'S SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad Bldg Inspection Request
For 10/30/2001
Permit# CB011991
Title ALDERTON - RAD 457 SF
Description
Type RESDNTL Sub Type RAD
Job Address 2903 CORTE CELESTE
Suite Lot 0
Location
APPLICANT ALDERTON SETH
Owner ALDERTON FAMILY TRUST 05-10-01
Remarks
Inspector Assignment TP
Phone 7604363435
Inspector
Total Time Requested By DENNIS
CD
19
29
39
49
Entered By CHRISTINE
Description Act Comments
Final Structural tfjP
Final Plumbing i
Final Electrical , /
Final Mechanical _L
Associated PCRs
Date
09/17/2001
09/17/2001
09/10/2001
09/10/2001
08/17/2001
08/17/2001
07/13/2001
07/13/2001
07/12/2001
07/12/2001
Inspection History
Description
17 Interior Lath/Drywall
18 Exterior Lath/Drywall
16 Insulation
84 Rough Combo
14 Frame/Steel/Boltmg/Welding
15 Roof/Reroof
1 1 Ftg/Foundation/Piers
12 Steel/Bond Beam
1 1 Ftg/Foundation/Piers
12 Steel/Bond Beam
Act
AP
AP
AP
AP
PA
AP
AP
AP
CO
CO
Insp
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
Comments
•WINDOW @ DOOR REQ TEMP
OK TO WRAP
SHR WALL CNG @ PLUMB
i^X
EsGil Corporation
In Partnership with Government for Building Safety
DATE JUNE 25, 2001
JURISDICTION CARLSBAD
PLAN CHECK NO 01-1991 SET II
PROJECT ADDRESS 2903 CORTE CELESTE
PROJECT NAME SFR ADDITION FOR ALDERTON
Q APPLICANT
a JURIS
a PLAN REVIEWER
a FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are;submitted for redneck _
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
X3 Esgil Corporation staff did not advise the applicant that the plan check has been completed
I | Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) i f , Fax #
Mail Telephone Fax In Person
XI Corrections Applicant to note on the cov^Ksrieet of
following notes In the U-Factor
new energ
sheet GF-1R, Page 1, the
olumn, note 0 45 (per
By AH Sadre
Esgil Corporation
D GA D MB D EJ
Enclosures
PC LOG trnsmtl dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576
EsGii Corporation
In (Partners/lip With (jove.mme.nt for 'Bu.tCding Safety
DATE JUNE 15, 2001
JURISDICTION CARLSBAD Q PLAN REVIEWER
a FILE
PLAN CHECK NO 01-1991 SET I
PROJECT ADDRESS 2903 CORTE CELESTE
PROJECT NAME SFR ADDITION FOR ALDERTON
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
| | The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck PLEASE SEE BELOW
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Seth Alderton 2903 Corte Celeste, Carlsbad, CA 92009
Esgil Corporation staff did not advise the applicant that the plan check has been completed
]X] Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Seth LM Telephone # 760-436-3435
Date contacted Lo^Vb (by ~j^ Fax # Lf^Lc
Telephone --"' Fax^^ In Person
XI Corrections # 1) Submit two sets of revised plans to the EJuildmg Department for review
# 2) Please show tempered glass in window adjacent to the door in family room # 3) Please
show compliance with the attached revised T-24 energy requirements effective June 1st, 2001
Please make sure the completed & revised CF-1R forms are imprinted on plans
By All Sadre Enclosures
Esgil Corporation
D GA D MB D EJ D PC 6/11 \ trnsmtldot
9320 Chesapeake Dnve, Suite 208 4 San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576
VALUATION AND PLAN CHECK FEE
JURISDICTION CARLSBAD PLAN CHECK NO 01-1991
PREPARED BY All Sadre DATE JUNE 15, 2001
BUILDING ADDRESS 2903 CORTE CELESTE
BUILDING OCCUPANCY R3/U1 TYPE OF CONSTRUCTION VN
BUILDING
PORTION
LIVING ADD
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
437
CB
1 QQ4 1 IRr Ri ulrlinn Pprmif FPP ^
Valuation
Multiplier
By Ordinance
Reg
Mod
VALUE ($)
45,011
$377.13
1994 UBC Building Permit Fee $245.13
Type of Review Complete Review fj Structural Only
[H Repetitive Fee
Repeats
D Other
D Hourly Hour
Esgil Plan Review Fee $196.11
Comments
Sheet 1 of 1
macvalue doc
9320 Chesapeake Dnve, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576
BUILDING PLANCHECK CHECKLIST
Q_LDATE
BUILDING ADDRESS .
PROJECT DESCRIPTION
ASSESSOR'S PARCEL NUMBER
PLANCHECK NO CB
- IL/& -EST VALUE
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans,
information and/or specifications provided in your
submittal, therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build
A Right-of-Way permit is required prior to
construction of the following improvements
DENIAL
Please seathe, attached report of deficiencies
marked with^Q^Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review
Date
Date
DateBy
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT.
Date.
MENTS
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
ENGINEERING DEPT CONTACT PERSON
Name JOANNE JUCHNIEWICZ
City of Carlsbad
Address 1635 Faraday Avenue, Carlsbad, CA 92008
Phone (760) 602-2775
CFD INFORMATION
Parcel Map No
Lots
Recordation
Carlsbad Tract
A-4
H \WORD\DOCS\CHKLSTBuik)ing Planctieck Cklst Form (Generic) doc
cr 83 -
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 Provide a fully dimensioned site plan drawn to scale Show
A North Arrow
B Existing & Proposed Structures
C Existing Street Improvements
D Property Lines
asements
Show on site plan
F Right-of-Way Width & Adjacent Streets
G Driveway widths
H Existing or proposed sewer lateral
I E xistmg or proposed water service
J Existing or proposed irrigation service
D
Drainage Patterns
1 Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
Existing & Proposed Slopes and Topography
Size, type, location, alignment of existing or proposed sewer and water service
(s)_that serves the project Each unit requires a separate service, however,
second dwelling units and apartment complexes are an exception
Sewer and water laterals should not be located within proposed driveways, per
standards
3 Include on title sheet
A Site address
B Assessor's Parcel Number
C Legal Description
For commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc ) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
H \WORD\DOCS\CHKLST\Bullding Plancheck Cklst Form (Generic) doc
BUILDING PLANCHECK CHECKLIST
2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE
D D 4a Project does not comply with the following Engineering Conditions of approval for
Project No __
4& A" conditions are in compliance Date
DEDICATION REQUIREMENTS
D D 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm
dram or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $15.000. pursuant to Carlsbad
Municipal Code Section 18 40 030
Dedication required as follows
Dedication required Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 V* x 11" plat map
and submit with a title report All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit Attached please find an
application form and submittal checklist forthe 'dedication process Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person Applications will not be accept by mail or fax
Dedication completed by Date
IMPROVEMENT REQUIREMENTS
D D 6a All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section
1840040
Public improvements required as follows
Attached please find an application form and submittal checklist for the public
improvement requirements A registeied Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process The completed application form and the requirements on the
H \WORD\DOCSVCHKLST\BuildinoPlanctieckCklst Form (RIDDLE HARVEY 7 12-00) doc Q Rev 1226/96
BUILDING PLANCHECK CHECKLIST
I ST 2ND 3rd
checklist must be submitted in person Applications by mail or fax are not
accepted Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit
Improvement Plans signed by Date
D D D 6b Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1840 Please submit a recent property title report or
current grant deed on the property and processing fee of $280 so we may
prepare the necessary Neighborhood Improvement Agreement This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit
•
Neighborhood Improvement Agreement will include the following
D D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return
agreement signed and notarized to the Engineering Department
Neighborhood Improvement Agreement completed by
Date
n 6d No Public Improvements required SPECIAL NOTE Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11 06 030 of the Municipal Code
Q fJJ O 7a Inadequate information available on Site Plan to make a determination on grading
requirements Include accurate grading quantities (cut, fill import, export)
CU CD [U 7b Grading Permit required A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached NOTE The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit
Grading Inspector sign off by Date
D Q D 7c Graded Pad Certification required (Note Pad certification may be required even
if a grading permit is not required )
H \WORO\DOCS\CHKlST\BuikJing Planctieck Cklst Forni (RIDDLE HARVEY 7 12 00) doc
1ST oND oRD
D D.
D D D
BUILDING PLANCHECK CHECKLIST
7d No Grading Permit required
7e If grading is not required, write "No Grading" on plot plan
MISCELLANEOUS PERMITS
8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way Types of work include, but are
not limited to street improvements, tree trimming, driveway construction, tying
into public storm dram, sewer and water utilities
Right-of-Way permit required for
D D
D
D
D
INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 7153,
for assistance
Industrial Waste permit accepted by
Date
11
10 NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first
uired fees are attached
No fees required
WATER METER REVIEW
12a Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized
Oversized meters are inaccurate during low-flow conditions If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used
• All single family dwelling units received "standard" 1" service with 5/8" service
H WORD\OOCS\CHKLS~nBuik!ing Plancheck Cklst Form (Genenc) doc Rev 7/14/00
1ST •>ND 3RD
D 12b
BUILDING PLANCHECK CHECKLIST
• If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm) A typical fixture count and water demand worksheet is
attached Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit
• Maximum service and meter size is a 2" service with a 2" meter
• If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand (manifolds are considered on case by case basis to limit
multiple trenching into the street)
Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval The developer must provide these calculations Please follow
these guidelines
1 If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets If so, at the water meter station, the demand in
gpm may be listed there Irrigation services are listed with a circled "I",
and potable water is typically a circled "W" The irrigation service should
look like
STA 1+00 Install 2" service and
5 meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach) Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use Once
you have received a good example of irrigation calculations, keep a set for
your reference In general the calculations will include
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (largest, farthest away from valve
• Total Sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA) As long as the project is located within the City recycled water
H \WORD\DOCS\CHKLST\Building Plancheck Cklst Form (Generic) doc
ST oND 3RD
BUILDING PLANCHECK CHECKLIST
service boundary, the City intends on switching
services/meters to a new recycled water line in the future
12c Irrigation Use (where recycled water is available)
these irrigation
1 Recycled water meters are sized the same as the irrigation meter above
2 If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development For
subdivisions, this should have been identified, and implemented on the
improvement plans Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this
G D 13 Additional Comments:
H \WORD\OOCS\CHKLST\BuiUing Plancheck Cklsl Form (Generic) doc
-a * *v
•YI.I.
u,
•-.V.
Oo
0
0
0
M
-T-i
2ft3v
%
A
^
i7^
'>
iK.4J^
O
^•J
2T,
o
&,
v VM.:u-
do
J^
O
•ij-66
oo
O
5
Z
c
o
-so-,1 ^
67
%t-»
SN
a;rf»
"1
*\
<b6
,Jf,~,:. -•-;; :---'-
.0s
CJcm
D-!0-
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEEW CHECKLIST
Plan Check No
Planner Paul Godwin
APN
Address
Phone
fak.
760-602-4625
Type of Project & Use
Zoning
CFD (in/out) #_
Circle One
. General Plan
Net Project Density
_ Facilities Management Zone
DU/AC
Date of participation Remaining net dev acres
(For non-residential development Type of land used created by this
permit )
Legend:/\ Item Complete [ | Item Incomplete - Needs your action
Environmental Review Required: YES NO X^ TYPE
DATE OF COMPLETION
Compliance with conditions of approval9 If not, state conditions which require action
Conditions of Approval
I | Discretionary Action Required: YES _
APPROVAL/PESO NO DATE
PROJECT NO
NO V TYPE
OTHER RELATED CASES
Compliance with conditions or approval9 If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone9 YES_
CA Coastal Commission Authority9 YES_NO
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Dr, Suite 103, San Diego
CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt) _
NOCoastal Permit Determination Form already completed9 YES
If NO, complete Coastal Permit Determination Form now
Coastal Permit Determination Log # __
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor
Plans)
2) Complete Coastal Permit Determination Log as needed
H \ADMIN\COUNTER\BldgPlnchkRevChklst
Inclusionary Housing Fee required: YES
(Effective date of Inclusionary Housing Ordinance - May 21,1 993 )
NO v^f ~
Data Entry Completed'? YES NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE1)
Site Plan:
1 Provide a fully dimensional site plan drawn to scale Show North arrow, property
lines, easements, existing and proposed structures, streets, existing street
improvements, right-of-way width, dimensional setbacks and existing topographical
lines
2 Provide legal description of property and assessor's parcel number
Zoning:
_X 1 Setbacksi
Front
Interior Side
Street Side
Rear
Y 2 Accessory structure
Front
Interior Side
Street Side
Rear
Structure separation
S^l 3 Lot Coverage
Required $O
Required (£»
Required $
Required ' (a
setbacks
Required
Required
Required
Required
Required
Required "iV/QO^U
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
$S Shown
35
(/>
i ST
(j>O
w*^
4 Height Required Shown
5 Parking Spaces Required
Guest Spaces Required
Additional Comments
Shown
Shown
OK TO ISSUE AND APPROVAL ENTERED INTO COMPUTER U)t3£j?£d>V DATE
H \ADMIN\COUNTER\BldgPlnchkRevChklst
<_. i»aBS^»"l
rH£"J B S 8 fi 5 B-"-1li m r
«
il[f«•» &.. . 8*3*rlriM^lisiHi5B«?Iilb
li «w r-1
![.{
u
o o o o
5 ? ° 5" c5 » n i5 -iW i ^1
r-V/l
S E *iis
=12
LIB MX
.-o3S 1"
---*
i!
^§
sit
o»,1
^
oo
I
OB:4OA Denms Mat-hns 7504368(529 P . O2
STRUCTURAL CALCULATIONS
ALDERTON RESIDENCE
CARLSBAD, CA
Prepared For:
SETH & TAMi ALDERTON
Date Issued. 6/1/01
Revision Dates:
Prepared By:
Michael A. McNeff, P.E.
1936 Park Dale Lane
Encinitas, CA 92024
\V
Jun-O4-Ql OS:4GA Derm -i s, Math n s 7604368629 P .03