Loading...
HomeMy WebLinkAbout3451 VIA MONTEBELLO; 192; CB142425; Permit10-09-2014 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: Building Inspection Request Line (760) 602-2725 CB142425 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group; Project Title: 3451 VIA MONTEBELLO CBADSt: 192 Tl Sub Type: COMM 2230507200 Lot #: 0 $48,865.00 Construction Type: 5A Reference # POSTAL ANNEXiSHELL TO 1,128 SF POSTAL ANNEX CENTER Status: ISSUED Applied; 09/19/2014 Entered By; JMA Plan Approved; 10/09/2014 Issued: 10/09/2014 Inspect Area Plan Ciieck #: Applicant; LISA FRITZSHING 3578 30TH ST SAN DIEGO CA 619-236-0595 92104-4143 Owner: PROPERTY DEVELOPMENT CENTERS LLC C/O SAFEWAY INC 5918 STONERIDGE MALL RD PLEASANTON CA 94588 Building Permit $399.13 Meter Size Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00 Plan Check $279.39 Meter Fee $0.00 Add'l Building Permit Fee $0.00 SDCWA Fee $0.00 Plan Cfieck Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $13.68 PFF (3105540) $889.34 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $63.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $99.00 Other Building Fee $0.00 MECHANICAL TOTAL $51.52 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green BIdg Stands (SBI473) Fee $1.00 HMP Fee ?? Fire Expedidted Plan Review $0.00 Green BIdg Standards Plan Chk ?? TOTAL PERMIT FEES $1,796.06 Total Fees: $1,796.06 Total Payments To Date: $1,796.06 Balance Due: $0.00 inspector: FINAL AP Date: Clearance: NOTICE: Please take NfiTICEwiat approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required Information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service tees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv othenwise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: Ql PLANNING JENGINEERING DBUILDING jFIRE ] HEALTH •HAZMATfAPCD CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 Ph; 760-602-2719 Fax: 760-602-8558 email: buildlng@carlsbadca.gov www.carlsbadca.gov Plan Check No. Est. Value Plan Ck. Deposit Date SWPPP JOB ADDRESS ^^^^ MONTEBLLO SUITE#/SPACE#/UNIT* 192 APN ^ CT/PROJECT# L0T# PHASE# # OF UNITS 1 # BEDROOMS 0 # BATHROOMS 1 TENANT BUSINESS NAME POSTAL ANNEX CONSTR. TYPE V-B occ. GROUP B DESCRIPTION OF WORK: /nc/ude Square Feet of Affected Areafs) 1128 SF TENANT IMPROVEMENT FOR POSTAL ANNEX (N) PLUMBING FOR (N) ACCESSIBLE BATHROOM, (N) DUCTING FOR (E) ROOFTOP RTU. EXISTING USE JWACANI- PROPOSED USE Dryclean Agency GARAGE (SF) N/A PATIOS (SF) N/A DECKS (SF) N/A FIREPLACE YES|~|# NoTTI AIR CONDITIONING YES \7]m I I FIRESPRINKLERS YESPTlNOj I APPLICANT NAiVIE Primary Contact LISA FRITZSCHING PROPERTY OWNER NAME ADDRESS 3578 30TH ST ADDRESS 3410 VIA MERCATO CITY SAN DIEGO CA 92104 CARLSBAD STATE CA ZIP 92009 619-236-0595 FAX 619-236-0557 PHONE 760-705-0791 EMAIL lisa@mpa-archltects.com EMAIL MPA ARCHITECTS ^'"W.TIIT^^ ^imf^^^aj t^fli\^,A^ DESIGN PROFESSIONAL ADDRESS 3578 30TH ST ^iF-l Cm CITY SAN DIEGO STATE CA 92104 PHONE 619-236-0595 619-236-0557 EMAIL rfce"also requires the ' STATE LIC. # C24051 CITY BUS. LIC. (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to Its Issuarfce, also requires the applicant for such permitto file a signed statement that he Is licensed pursuantto the provisions of the Contractor's License Law (Criapter 9, commendingwlth Section 7000 of Division 3 ofthe Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the appiioant to a civil penaity of not more than five hundred dollars ($500)). 7- Woriiers' Compensation Declaration: / hereby afflmi under penaity ofpeijury one ofthe foiiowing declarations: LJ I have and wiil maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. i^rvi have and will maintain wo^gu'S'c^mDen9|itlon, as requjrgd bv Section 3700 of tt)e.Labor Cede, forthe perfonnanjeof the work forAvWch this pemjt^ issued. My workers'compensatipn insjjfartcegafrlSrand policy ^ number are: insurance Co. ,r'l%|v^(.QVV^_]f^\^C|/^ J PolicvNo. '^Cf^ ir'^ ^l^-" I j Expiration Date'3? ( 2^ I tj This section need not be completed If the permit is for one h|ndred dollars ($100) oVlels. / I I Certificate of Exemption: I certify that in the perfonnance^haiwork forwhich this pemiit is issued, I shaii notemploy any person in any manner so asto become subjectto the Workers'Compensation Laws of Califomia. WARNING: Failure to s^re woriters' compensanpri coverage Is unlawful, and shaii subject an employerto criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, cfamages as provlfled If \ji Section 3706 of the Labor code, interest and attomey's fees. JS^ CONTRACTOR SIGNATURB j0 AGENT DATE / hereby affirm that I am exempt frofn Contractor's Ucense Law for the following reason: I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec, 7044, Business and Prafessions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such wort( himself or through his own employees, provided that such improvements are not intended or offered for sale. If, hovrever, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of saie). I I I, as ovmer of the property, am exclusively contracting with licensed contractors to constmct the project (Sec. 7044, Business and ProfessionsCode: The Contractor's License Law does not apply to an owner of property viho builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I I I am exempt under Section Business and Professions Code for this reason: 1,1 personally plan to provide the major labor and materials for constmction of the proposed property improvement QVes I INO 2.1 (have / have not) signed an application for a building pennit for the proposed wort(. 3.1 have contracted with the foiiowing person (firm) to provide the proposed constmction (Include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and pravide the major wori( (Include name / address / phone / contractors' license number): 5. i will provide some of the work, but i have contracted (hired) the foiiowing persons to provide the vrark Indicated (include name / address / phone / type of won<): jgS'pROPERTY OWNER SIGNATURE QAGENT DATE is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the appiicant or future building occupant required to obtain a pemiit from the air pollution control district or air quality management district? Yes No Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FiNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AiR POLLUTION CONTROL DISTRiCT. I hereby affirm that there is a constmction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address 1 cert% that 1 have read ttie application and state that the above Information Is conect and that the infomiation on the plans Is accura^^ I hereby authorize representative of the City of Carisbad to enter upon the above mentbned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pemiit is required for EXPIRATION: Every pemiit BSued by the 180 days fram the date of such pemiiLer' j^APPLICANT'S SIGNATUI ilition or constmctbn of stmctunes over 3 stories in heighl IS of this Code shall expire by limitatbn and become null and void if the building or wort( authorized by such pemiit is not commenced wilhin such permit e suspended or abandoned at any time after the work is commenced for a period of 180 days (Sectbn 106.4.4 Unfomi Building Code). DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building(S).carlsbadca.gov or Mall the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carisbad, Califomia 92008. C0#: (Office Use Only) CONTACT NAIVIE OCCUPANT NAIVIE ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE Carlsbad CA PHONE OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCU PANT (Listed above) CONTRACTOR (On Pg. 1) MAIL TO: CONTACT (Listed above) CONTRACTOR (On Pg. 1) OCCUPANT (Listed above) ASSOCIATED CB# MAiL / FAX TO OTHER: NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ^ef APPLICANT'S SIGNATURE DATE Inspection List Permit*: CB142425 Type: Tl COMM POSTAL ANNEX:SHELL TO 1,128 SF POSTAL ANNEX CENTER Date Inspection Item Inspector Act Comments 11/19/2014 89 Final Combo -Rl COF 11/19/2014 89 Final Combo PY AP 11/17/2014 23 Gas/Test/Repairs -Rl #192 POSTAL ANNEX 11/17/2014 23 Gas/Test/Repairs PY AP 11/14/2014 33 Service Change/Upgrade -Rl STE192 POSTAL ANNEX 11/14/2014 39 Final Electrical MC AP CALLED IN 11/13/14 11/14/2014 89 Final Combo -Rl STE 192 POSTAL ANNEX COF 11/14/2014 89 Final Combo MC NR 11/13/2014 39 Final Electrical MC AP CALLED IN TO SDGE VOICE MAIL 10/29/2014 17 Interior Lath/Drywall PY AP 10/27/2014 84 Rough Combo MC AP WALLS 10/20/2014 21 Underground/Under Floor MC AP Wednesday, November 26, 2014 Page 1 of 1 INSPECTION RECORD OT If Of CARLSBAD Building DIvtsion 0 INSPECTION RECORO CARD WITO APPROVEO PLANS MUST BE-KEPqCON THE JOB 0 CALL BEFORE 3;30 prnVoR NEXT WORK DAY iNSPECTION la FOR BUILDINGIKISPECTION CALL: 760-602-2725^ OR GO TO: wvyw.CarUbadca.QOV/Bulldlng AND CLICK ON "Request Inspection" DATE: /of *-? / / W IF "YCS" IS CW:<;KI,:O ncLow WAT DIVISION'S APPROVAL IS nmmRED rmrm TO my3,m:':,rmQ ,\ FIN.M OMII ofNn !NM-I TTION IF YOU HAVE ANY OUEOTIorJS PLCASE CALL TOE APPLICAiJtL dlVISIONs" ATIll PHONe "'llll Mill sr; p,jr,Vinfrf>"f 41 „w Z'trii ALL REQUmCO APPPOVALS ARC SIGHLfl OFF- FAX TO 760-G02^-«56C), EMAIL TO PLTCWSrrC? lOMnfi'rARf-.tiAnr A,/u,v OR BRING IN A COf'Y OF TfllS CAPD TO: 1 635 FAf?AOAY AVE.. CAIJLSOAD. CA 92«»8r" eUliOlNo''IN^PECTOK'^ EAN DiZZ m n AT 76O-6O2-2700 BETWEEN 7:30 AM 8:00 AM THE DAT OF fOlJK INSPECTION. CB14242k_^ 3451 VIAMONTEBELLO 192 POSTAL ANNEX:SHELL TO 1 128 SF POSTAL ANNEX CENTER Ti COMM Lot#; LISA FRITZSHING RECORD COPY YIS Reiiufreif PrtcNr to Requestfng Building Pimir If CHmMxA ¥ES Date Inspector Notes l/ Plannina/Undseape 760-944-8463 Aifcwv 48 hours y ^ CM&I (Engineering Ifwpeetlon*) 76{M3S-389t Call before 2 pm y Fire Prevention 760-602-4660 Allow 48 hours Type of Inspection ni FOUNDATION CODE# BUiLDING Date #12 RBNFORCED Sim Inspector Type of Inspection mi • ELECTRIC UNDERGROUND • UFER Oate »3» ROUGH ELECTRIC PfLECTBIC SERVICE • TEMPORARV inspector #66 MASONRY mE GROUT #33 • GROUT • WALL DRAINS #35 PHOTOVOLTAIC #10 TILTPANELS Ml POURSIRIPS #11 COLUMNFOOTINGS #14 SUBFRAME •FLOOR DCEIUNO #39 FINAL coor: a MECHANfCAl. #41 UNDERGROUND DUCTS ft PIPINO **4 • OUCT ft PLENUM DREF. PIPINO «1S ROOFSHEATHINO #43 HEAT-AIR CONO. SVSTEMS #13 EXT. SHEAR PANas «ie WSULAHON #18 E3CTERI0RUTH #17 INTERIOR UTH ftORVWAU #51 POOL EXCA/STEEt/BOND/FENCE i-V^\i4 M»; .FIRAI, CDor.if COMBOINSPECTION #81 UNDERGROUND (11,12,21.31) #82 DRYWALUEXTLATH,GASTES(17.18J3) #83 ROOf SHEATING, EXT SHEAR (13.15] #5S PREPLASTER/FINAL #19 FINAL #84 FRAME ROUGH COMBO (l«,24.34.44) CODES PLUMBING #22 DSEWER&BL/CO •Pl/C6 .M #21 UNDERGROUNOP^ASTE DWTR 7^ inspector #85 T-Bar (14,24,34,44) #8FFlWAL0CCUPANCT"("i9l9^^ #24 TOPOUT DWASTE DWTR A/S UNDERGROUND VISUAL A/S UNDERCIROUND HYDRO #27 TUB & SHOWER PAN #23 DGASTEST DBAS PIPINQ #25 WATER HEATER A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL »28 SOLARWATER 1^ vmt A/S OVERHEAD HYDROSTATIC oDe» STORM WATER ^600 PRE-CONSTRUCTION MEETING A/S FINAL F/A ROUQH-IN F/A nNAL ?603 FOLLOW UP INSPECTION FIXED EXTINOUISHINO SYSTEM ROUQH-IN *605 NOTICETO CLEAN FIXED EXTINQ SYSTEM HYDROSTATICTEST '607 WRITTEN WARNING FIXED EXTINOUISHINO SYSTEM FINAL 609 NOTlCEOFVIOlATiON MEDICAL QAS PRESSURE TEST 610 VERBALWARNINO MEDICAL QAS FINAL /licheal Palmer From: Sent: To: Cc: Subject: Attachments: Jim Bruno <jim(§)pacificincorp.com> Monday, October 06, 2014 11:10 AM nnpalmer@mpa-architects.com rayd)pacificincorp.com; dadcollo@aoLcom FW: Postal Annex / La Costa PAC10062014.pdf Hello Mike, Please see attached information for you to pull the permits for the Postal Annex located at 3451 Via Monabello, Carlsbad. Ifyou need anything further, let me know. Thank you, Jim Please note our new address and email PACIFIC COMMERCIAL CONSTRUCTION Jim Bruno President jim&pacificincorp.com 7668 El Camino Real, #104-500 Carlsbad, CA 92009 Mobile 760.801.8800 Office 760.943.1975 Fax 760.683.6612 EsGil Corporation In (Partnersfiip •witH government for CBuiCcCing Safety DATE: 10/3/2014 • APPLiCANT • JURIS. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLANCHECKNO.: 14-2425 SET: II PROJECTADDRESS: 3451 Via Montebllo Suite 192 PROJECT NAME: Postal Annex, TI The plans transmitte(d herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transnriitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The pians transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check iist is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: Lisa Fritzsching, 3578 30'^ St. San Diego, CA, 92104 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Lisa Fritzsching Telephone #: 619-236-0595 Date contacted: (by: ) Email: lisa@mpa-architects.com Fax #: 619-236-0557 Mail Telephone Fax In Person XI REMARKS: Lisa Fritzcshing did over the counter recheck at Esgil Corp. By: Glen Adamek Enclosures: EsGil Corporation Kl GA • EJ • MB • PG 10/3/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Caiifomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In cpartnersHip tvitfi government for cBuiUing Safety DATE: 9/29/2014 • APPLICANT ^a^jURis. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLANCHECKNO.: 14-2425 SET: I PROJECTADDRESS: 3451 Via Montebllo Suite 192 PROJECT NAME: Postal Annex, TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. XI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Lisa Fritzsching, 3578 30*''St. San Diego, CA, 92104 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Lisa Fritzsching Telephone #: 619-236-0595 /Date contacted: ^/T^^ {by-.y^r^ Email: lisa(a)mpa-architects.com Fax #: 619-236-0557 *^5wiail ^^Telephone Fax In Person • REMARKS: By: Glen Adamek Enclosures: EsGil Corporation • GA • EJ • MB • PC 9/22/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLANCHECKNO.: 14-2425 JURISDICTION: Carlsbad OCCUPANCY: B USE: Postal Store TYPE OF CONSTRUCTION: ? ACTUAL AREA: 1,128 ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: unknown SPRINKLERS?: ? OCCUPANT LOAD: 11 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 09/19/2014 DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/22/2014 DATE INITIAL PLAN REVIEW COMPLETED: 9/29/2014 PLAN REVIEWER: Glen Adamek FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval ofthe plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copv) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. [DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Glen Adamek BUILDING ADDRESS: 3451 Via Montebllo BUILDING OCCUPANCY: B PLANCHECKNO.: 14-2425 DATE: 9/29/2014 BUILDING PORTION AREA ( Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Tl per city value 48,865 Air Conditioning Fire Sprinklers TOTAL VALUE 48,865 Jurisdction Code cb By Ordinance BIdg. Permit Fee by Ordinance $400.09 Plan Qieck Fee by Ordinance Type of Review: •Repetitive Fee Repeats • Complete Review • Other ^ Hourly EsGil Fee • Structural Only Hr. @ $260.06 $224.05 Comments: Sheet 1 of 1 macvalue.doc + 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGii Corporation is complete. 2. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: • Occupancy Classification(s) B • Description of Use Postal Store • Type of Construction ? • Sprinklers: Yes or No ? PLUMBING (2013 CALIFORNIA PLUMBING CODE) 3. Provide a plumbing material schedule on the plans describing the following systems: Potable water piping, gas piping, condensate drain lines and the drain, waste, and vent piping. 4. Provide calculations to show compliance with CPC Section 422 & Table 422.1. (Minimum Plumbing Facilities). Please provide a mop sink or service sink. 5. Please provide required water heater. Hot water is required for public use washing fixtures such as lavatories. CPC 601.1. 6. On the water line plans show the required tempering valve. Describe the method of compliance for temperature limitations for the public use lavatories (limited to 110 degrees). Note: The water heater thermostat may not be used for compliance with this Code section. CPC 421.2. Energy Standards 110(C)3. 7. Show the type, make and model of the water closet. 8. Provide complete water line sizing calculations: Include the water pressure, pressure loss calculations, water demands, and the developed pipe lengths. CPC 610.0 or Appendix 'A'. MECHANICAL (2013 CALIFORNIA MECHANICAL CODE) Mechanical plans seem to substantially comply with the jurisdiction's mechanical codes. ELECTRICAL (2013 CALIFORNIA ELECTRICAL CODE) Electrical plans seem to substantially comply with the jurisdiction's electrical codes. ENERGY (2013 CALIFORNIA BUILDING ENERGY STANDARDS) 9. Complete the lighting control energy form NRCC-LTI-02-E form. 10. Shut-Off Controls: Each floor, each space (not exceeding 5,000 square feet), and each type (general, display, and ornamental) of lighting shall be individually capable of being automatically shut-off when the building is unoccupied. Include the control design. (A percentage of egress lighting is now included in the shut-off requirement). ES 130.1(c) 11. The Certificate of Compliance Form NRCCLTI-01-E must be signed. GENERAL 12. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 13. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please brieflv describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes • No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Glen Adamek at Esgil Corporation. Thank you. <!/^jmz CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL e ^ «^ommunity & Economic Development Department 1635 FaradayAvenue Carlsbad CA 92008 www.carisbadca.gov DATE: 10-2-14 PROJECTNAME: Postal Annex PROJECTID: PLANCHECKNO: CB142425 SET#: 1 ADDRESS: 3451 Via Montebello APN: • This plan check review is complete and has been APPROVED by the Fire Division. By: D. Fieri A Final Inspection by the Fire Division is required |^ Yes n No This plan check review is NOT COIVIPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Ybu may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance ofa buiiding permit. Resubmitted plans should inciude corrections from all divisions. For questions or clarifications on the attachied checklist please contact the following reviewer as mariced: ITiilitlMHIMMMfc " ~ 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.£ov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 GregorY.RYari@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Glna.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Llnda.Ontlveros@carlsbadca.gov Q Cindy Wong 760-602-4662 Cvnthla.Wong@carlsbadca.gov • • X Dominic Fieri 760-602-4664 Domlnlc.Fieri@carlsbadca.gov Remarks: Carlsbad Fire Department -BLDG. DEPT C(>PY Plan Review Requirements Category: TI, COMM Date ofReport: 10-02-2014 LISA FRITZSHING Reviewed by: Name: Address: 3578 SOTH ST SAN DIEGO CA 92104-4143 Pennit #: CBI42425 Job Name: POSTAL ANNEXrSHELL TO 1,128 SF Job Address: 3451 VIA MONTEBELLO CBAD St: 192 INCOl^PfcK^ The ite^pT^iiJjaye submittedfofTCV^ivis incomplete. ^Tliii^me, this dEI5«i,cannot adequatelyconauN^revie\Apdetermhi^^mplianceWithth^SBnlicablecoobsand/o^tandard\ Ple^iserevi^ calTffWJ^^iiconimeniS^tache^ Please restfbmjt the naif essary plM*s^d/or sp(pcification^5^ith cfianges >lguJled", to this om^Mor review aiKi^p\val. Cond: CON0007732 [MET] THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 10/02/2014 By: df Action: AP PLAN CHECK PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www.carisbadca.gov DATE: 9/24/14 PROJECT NAME: LCTS tenant improvement_ Postal Annex PROJECTID: PLAN CHECK NO: CB142425 SET#: I ADDRESS: 3451 Via Montebello (BIdg #23) pp^. 223-050-72-00 VALUATION: $48,865 APPLICANT CONTACT: lisa(S)mpa-architects.com X THs plan check review transmittal is to notify you of clearance by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspe ction by the Construction & Inspection Division is required: Yes No X ©f For status from a division not marked below, please call 760-602-2719 This plan check review is NOTCOMPLETE Items missing or incorrect are listed on the attache d checklist. Please resubmit amended plans as required. 1 |||||||Ji|||;B™ LAND DEVELOPMENT ENG. 760-602-2750 1 X L Linda Ontiveros 760-602-2773 mda.Ohtiveros@carlsbadca.gov i -ii^ . .—— 1. Remarks: Engineering impact fees with CB130639 ^ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 FaradayAvenue (760) 602-4610 www.carlsbadca.eov DATE: 9-23-14 PROJECTNAME: PROJECTID: PLAN CHECK NO: CB 14-2425 SET#: 1 ADDRESS: 3451 Via Montebello APN: ^ This plan check review is complete and has been APPROVED by the Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes • No You may also have corrections from one or more of the divisions Hsted below. Approval from these divisions may be required prior to the issuance ofa building permit. Resubmitted plans should include corrections from all divisions. • This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: lisa@mpa-archltects.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGtNEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Rulz@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov Q Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominlc.Fieri@carlsbadca.gov Remarks: ^\ PLUMBING, Deveiopment Services ELECTRICAL, Building Division ^ riTY OF MECHANICAL 1635 Faraday Avenue ^ CiTY OF ...rNoixoLii^.^-r 760-602-2719 C ADI CRAri WORKSHEET www.carlsbadca.gov /i.l\L.«3D/%L/ B-18 Buildlng^carlsbadca.gov Project Address: Permit No.: Information provided below refers to work being done on ttie above mentioned permit only. This form must be completed and returned to the Buildinq Division before the permit can be issued. Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains New building sewer line? Ves No _ Number of new roof drains? Install/alter water line? \_ Number of new water heaters? \_ Number of new, relocated or replaced gas outlets? _jQ Number of new hose bibs? Residential Permits: New/expanded service: Number of new amps: Minor Remodel only: Ves No Commerdai/industrial: Tenant Improvement: Number of existing amps involved in this project: Number of new amps invohedin this project: New Construction: Amps per Panel: Single Phase Number of new amperes Three Phase Number of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? 0 New or relocated duct worb? Ves No Number of new fireplaces? Number of new exhaust fans? j, ^^ Relocate/install vent? (JL Number of new exhaust hoods? ^ Number of new boilers or compressors? Number of HP B-18 Page 1 of 1 Rev. 03/09 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / Business Name \ yQ^j^j^ i\ t^X' Business Contact Telephone # ( \ APN# Plan File* Occupancy Rating: 13. Corrosives The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are ^jrcldd^applicant must contact the Fire Prg^ction Agency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): ' I c> 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 2. Compressed Gases 6 Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Uquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials /l 5) None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to anv of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit^. FEES ARE REQUIRED YES N' • Project Completion Date ~hS'M f Occupancy: /Ai/^Q / )^ struction or reniodeling projects) n CalARP Exempt I Date Initials • CalARP Required / Date Initials • CalARP Complete I Date Initials Expected Date of (for new construction 1. • Is your business listed on the reverse side of this form? (check all that apply). 2. • Will your business dispose of Hazardous Substances or Medical Waste in any amount? 3. • lEl Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds 200 cubic feet, or carcinogens/reproductive toxins in any quantity? 4. • Will your business use an existing or install an underground storage tank? 5. • IM Will your business store or handle Regulated Substances (CalARP)? 6. • Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 7. • m Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act), PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.orq/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet ofthe outer boundary of a school (K through 12)? (Search the California School Directory at httD://www.cde.ca.aov/re/sd/ for public and private schools or contact the appropriate school district). Has a survey been performed to determine the presence of Asbestos Containing Materials? Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? Will there be demolition involving the removal of a load supporting structural member? YES NO 1. • C^ 2. • • 3. • 4. • 5. • riefly describe business activities: /1 I declare und knowledge anoltefief tl Briefly describe proposed project Name of Owner or Authorized Agent herein are true and correct. //J , , I ^// /o i/H FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: ignature of Owrfer or Authorized Agent Date FOR OFFIC^ALydSE ONLY DATE: / EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD *A stamp in this box onlv exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division INDUSTRIAL WASTEWATER DISCHARGE PERMIT . SCREENING SURVEY Date 0[- n f f- Business Name street Adciress V/S- l^lfmi^ mOrM&(</^ Email Address '/H2'iU^-r&.T'$. PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining / Milling Painting / Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuei Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting / Forming Pesticide Manufacturing / Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Film / X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap / Detergent Manufacturing Industrial Laundry. Waste Treatment/ Storage SIC Code(s) (if known):, Brief description of business activities (Production / Manufacturing Operations):. Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal / day): List hazardous wastes generated (type/volume): Date operation began/or will begin atthis location: Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: Site Contact Signaj! ENGI Title ^^h^^z-j^r Phone No. f/^ iZ^i^ ^f^^ ^ ATER AUTIIORITY/ 6200 Avenida Encinas Carls&acl, CA 92011 (760)'438-3941 FAX: (760)476-9852 DISCHARGE PERMIT EXEMPT LIST The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. Automobile Detailers Barber/Beauty Shops Business/Sales Offices Carpet/Upholstery Cleaning Services Childcare Facilities Churches Community Centers Consulting Services Contractors Counseling Services Educational Services (no auto repair/film developing) Financial Institutions/Services Fitness Centers Gas Stations (no car wash/auto repair) Grocery Stores (no film developing) Home-based Businesses Hotels/Motels (no laundry) Laundromats Libraries . Medicai Offices (no x-ray developing) Mortuaries Museums Nail Salons Nursing Homes Office Buildings (no process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services Public Storage Facilities Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) BUILDING ENERGY ANALYSIS REPORT PROJECT: POSTAL ANNEX 3451 VIA MOTENBELLO, #192 CARLSBAD, CA 92009 Project Designer: MPA ARCHITECTS 3578 SOTH ST SAN DIEGO, CA 92104 Report Prepared by: LISA FRITZSCHING MPA Architects, Inc. 3578 30TH ST SAN DIEGO , CA 92104 RECEIVED SEP 1 9 20H CITY OF CARLSBAD BUILDING DIVISION Job Number: 14320 Date: 9/6/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC-www.energysoft.com. EnergyPro 6.2 by EnergySoft User Number: 3835 ID: 14285 CB/H- 2.4 ZS TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form LTI-01-E Indoor Lighting 3 Form LTI-02-E Lighting Controls 9 Form LTI-03-E Indoor Lighting Power Allowance 13 j EnergyPro 6.2 by EnergySoft Job Number: ID: 14285 User Number: 3835 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI-Ol-E Indoor Lighting (Page 1 of 5) ProjectName: POSTAL ANNEX Date Prepared: 9/6/2014 Climate Zone: Conditioned Floor Area : 1,128 7 Unconditioned Floor Area : Q General Information Building Type: m Nonresidential • High-Rise Residential • Hotel/IVIotel • Schools • Relocatable Public Schools Conditioned Spaces • Unconditioned Spaces Phase of Construction: • New Construction • Addition • Alteration Method of Compliance: • Complete Building Area Category • Tailored UGHTING COMPUANCE DOCUMENTS (select yes for each document included) For detailecJ instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission. YES NO FORM TITLE YES NRCC-LIT-Ol-E Certificate of Compliance. All Pages required on plans for all submittals. YES NRCC-LIT-02-E Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. YES NRCC-LIT-03-E Indoor Lighting Power Allowance NO NRCC-LIT-04-E Tailored Method Worksheets NO NRCC-LIT-05-E Line Voltage Track Lighting Worksheets Summary of Allowed Lighting Power Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Ughting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces 1. Installed Lighting NRCC-LTi-Ol-E, page 4 Watts Installed Lighting NRCC-LTI-Ol-E, page 4 Watts 1. Installed Lighting NRCC-LTi-Ol-E, page 4 + 729 Installed Lighting NRCC-LTI-Ol-E, page 4 + 0 2. PORTABLE ONLY FOR OFFICES NRCC-LTI-Ol-E, page 3 + 3. IVlinus Lighting Control Credits NRCC-LTI-Ol-E, page 2 -70 Minus Lighting Control Credits NRCC-LTI-Ol-E, page 2 -0 4. Adjusted Installed Lighting Power (row 1 plus row 2 minus row 3) = 659 Adjusted Installed Lighting Power (row 1 minus row 3) = 0 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI-Ol-E Indoor Lighting (Page 2 of 5) Project Name: POSTAL ANNEX Date Prepared: 9/6/2014 5. Complies ONLY if Installed < Allowed ^ Complies ONLY if Installed < Allowed t 6. Allowed Lighting Power Conditioned NRCC-LTI-03-E, page 1 677 Allowed Lighting Power Unconditioned NRCC-LTI-03-E, page 1 0 Declaration of Required Installation Certificates - Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title NRCI-LTI-Ol-E - Must be submitted for all buildings • Field Inspector NRCI-LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), to be recognized for compliance. • Field Inspector NRCI-LTI-03-E - Must be submitted for a line-voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line-voltage track lighting, to be recognized for compliance. • Field Inspector NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a multipurpose room, or a theater to be recognized for compliance. • Field Inspector NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. • Field Inspector NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance. • Field Inspector Declaration of Required Certificates of Acceptance - Declare by checking all ofthe Certificates of Acceptance that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title NRCA-LTI-02-E - Must be submitted for occupancy sensors and automatic time switch controls. • Field Inspector NRCA-LTI-03-E - Must be submitted for automatic daylight controls. • Field Inspector NRCA-LTI-04-E - Must be submitted for demand responsive lighting controls. • Field Inspector CA BuiWmg Energy Efficiency Standards - 2013 Monresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION * CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI-Ol-E Indoor Lighting (Page 3 of 5) ProjectName: POSTAL ANNEX Date Prepared: 9/6/2014 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: Q CONDITIONED SPACE • UNCONDITIONED SPACE A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST • The actual indoor lighting power listed on this page and on the next page includes all installed permanent and planned portable lighting systems. • When Complete Building Method is used for compliance, list each different type of luminaire on separate lines. • When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines • Also include track lighting in schedule, and submit the track lighting compliance form (LTG-5C) when line-voltage track lighting is installed. B. Installed Portable Luminaires in Offices - Exception to Section 140.6(a) D This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of this compliance form. n This section is used to determine if greater than 0.3 watts of portable lighting is planned for any office • Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allowance shall not be traded between offices having different lighting systems. Office Portable Luminaire Schedule Office Installed Portable Luminaire Watts Per Square Foot AccountabI e Watts Office Location Field Inspector A B C D E F G H 1 J Complete Luminaire Description (i.e., LED, under cabinet, furniture mounted direct/indirect) Watts per Luminaire Numberof Luminaires Installed portable luminaire watts in this office (BxC) Square feet ofthis office Watts per square foot (D/E) If 0.3, enter zero; if F > 0.3, (F-0.3) ExG Identify Office area in which these portable luminaires are installed -a a> (/I to -n • • • • • • • • • • Total installed portable luminaire watts that are greater than 0.3 watts per square foot per office: Enter sum total of all pages into NRCC- LTI-Ol-E; Page 2 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION ' * ' CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI-Ol-E Indoor Lighting (Page 3 of 5) Project Name: POSTAL ANNEX Date Prepared: 9/6/2014 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: • CONDITIONED SPACE Q UNCONDITIONED SPACE A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST • The actual indoor lighting power listed on this page and on the next page includes all installed permanent and planned portable lighting systems. • When Complete Building Method is used for compliance, list each different type of luminaire on separate lines. • When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines • Also include track lighting in schedule, and submit the track lighting compliance form (LTG-5C) when line-voltage track lighting is installed. B. Installed Portable Luminaires in Offices - Exception to Section 140.6(a) • This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of this compliance form. • This section is used to determine if greater than 0.3 watts of portable lighting is planned for any office • Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allowance shall not be traded between offices having different lighting systems. Office Portable Luminaire Schedule Office Installed Portable Luminaire Watts Per Square Foot AccountabI e Watts office Location Field Inspector A B C D E F G H 1 J Complete Luminaire Description (i.e., LED, under cabinet, furniture mounted direct/indirect) Watts per Luminaire Number of Luminaires Installed portable luminaire watts in this office (BxC) Square feet ofthis office Watts per square foot (D/E) If FS0.3, enter zero; if F>0.3, (F-0.3) ExG Identify Office area in which these portable luminaires are installed -o 0) t/1 t/l TI • • • • • • • • • • Total installed portable luminaire watts that are greater than 0.3 watts per square foot per office: Enter sum total of all pages into NRCC- LTI-Ol-E; Page 2 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION ^«p6 CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI-Ol-E Indoor Lighting (Page 4 of 5) Project Name: pQSTAL ANNEX Date Prepared: 9/6/2014 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: a CONDITIONED SPACE • UNCONDITIONED SPACE C. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Luminaire Schedule Installed Watts Location Field Inspector ^ A B C D E F G H Name or Item Tag Complete Luminaire Description (i.e, 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballast) Watts per Luminaire How wattage was determined Number Luminaires Total Installed Watts in this area (CxE) Primary Function area in which these luminaires are installed Pass Fail Name or Item Tag Complete Luminaire Description (i.e, 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballast) Watts per Luminaire CEC Default from NAS According to §130.0(c) Number Luminaires Total Installed Watts in this area (CxE) Primary Function area in which these luminaires are installed Pass Fail 1 Lamp2ftF20T12/ES 25.0 • 1 25 All Others • • 2X4 FLOURESCENT 64.0 GZI • 11 704 All others • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • INSTALLED WATTS PAGE TOTAL: 729 Enter sum total of all pages into NRCC-LTI-Ol-E; Page 2 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION *?^P* CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI-Ol-E Indoor Lighting (Page 5 of 5) Project Name: pQSTAL ANNEX Date Prepared: 9/6/2014 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: LISA FRITZSCHING Documentation Author Signa Company; MPA Architects, Inc. Signature Date: 9/6/2014 Address: 3578 SOTH ST CEA/ HERS Certification Identification (if appliea Citv/State/Zip: SAN DIEGO , CA 92104 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws ofthe State of Caiifornia: 1. The information provided on this Certificate of Compliance is true and correct. 2. lam eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 ofthe California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building pe'rmif(5iissued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance^, required to be included with the documentation the builder provides to the building owner at occupancy. I MPA ARCHITECTS Responsible Designer Name. Responsible Designer Signature: Company: Date Signed: 3578 SOTH ST City/State/Zip: SAN DIEGO, CA 92104 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEC-NRCC-LTl-02-E (Revised 06/13) M CALIFORNIA ENERGY COMMISSION -"ft"^ CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page lof 3) ProjectName: pQSTAL ANNEX Date Prepared: 9/5/2014 The NRCC-LTI-02-E shall be used to document all mandatory and prescriptive lighting controls that are applicable to the project. A. Mandatory Lighting Control Declaration Statements Indicate ifthe measure applies: YES NO Control Requirements Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with Section 110.9. Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with Section 130.4(b). One or more Track Lighting integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and §130.0. An Installation Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4(b). A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.3. Additionally, an Installation Certificate shall be installed in accordance with Section 130.4(b). All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with Section 130.1. All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the multi-level lighting control requirements in accordance with Section 130.1(b). All installed indoor lighting shall be equipped with controls that meet the applicable Shut-OFF control requirements in Section 130.1(c). Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in accordance with Section 130.1(e). Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with Section 130.4.(a). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut-OFF controls, and demand responsive controls. Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance HERS Provider: June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION •" CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 2 of 3) ProiectNar^e. pQSTAL ANNEX Date Prepared: g/5/2014 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: • CONDITIONED SPACES • UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST Lighting Control Schedule Standards Complying With ^ (/ all that apply, or enter 'E' if Exempted) PAF Credit Calculation ^ ^ if Acceptance Test Required Field Inspector Lighting Control Schedule Standards Complying With ^ (/ all that apply, or enter 'E' if Exempted) Watts of Controlled Lighting -a > -n Control Credit ^ if Acceptance Test Required Field Inspector A B C D E F G H 1 J K L M N O Location in Building Type/ Description of Lighting Control (i.e.: occupancy sensor, automatic time switch, dimmer, automatic daylight, etc..) # of Units §130.1(a) §130.0(b) §130.1(c) §130.1(d) §130.1(e) §140.6(a)2 §140.6(d) •o QJ in v> m EXISTING LEASE SPACE Dimming - Manual / 704 0.10 70 / • • • • • • • • • • • • • • INSTALLED WATTS PAGE TOTAL: 70 IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF ALL PAGES HERE: 70 1. §130.1(aj = Manual area controls; §130.0(b) = Multi Level; §130.1(c) = Auto Shut-Off; §130.1(d) = Mandatory Daylight; §130.1(e) = Demand Responsive; §140.6(d) = Additional lighting controls installed to earn a PAF; §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6-A for correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also required to be filled out, signed, and submitted. Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance HERS Provider: June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEC-NRCC-LTI-Q2-E (Revised 06/13) CAUFORNIA ENERGY COMMISSION ' CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 2 of 3) ProjectName: pQSTAL ANNEX Date Prepared: 9/5/2014 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: • CONDITIONED SPACES • UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST Lighting Control Schedule Standards Complying With ^ (1^ all that apply, or enter 'E' if Exempted) PAF Credit Calculation o TO DJ 3: O S ^. — in 3 (D o TO Q. y, > r ~ n o ^ ;3 = fD (-* 35 fD .Q > n 0 (D •D r+ Oi O fD (D_ Q. •D fD B M Location in Building Type/ Description of Lighting Control (i.e.: occupancy sensor, automatic time switch, dimmer, automatic daylight, etc..) # of Units OJ o u> o cr u> o u> o o o CTl Q. • • • • • • • • INSTALLED WATTS PAGE TOTAL: IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF ALL PAGES HERE: 0 1. §130.1(a) = Manual area controls; §130.0(b) = Multi Level; §130.1(c) = Auto Shut-Off; §130.1(d) = Mandatory Daylight; §130.1(e) = Demand Responsive; §140.6(d) = Additional lighting controls installed to earn a PAF; §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6-A for correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also required to be filled out, signed, and submitted. Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance HERS Provider: June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 06/13) .. -m.. CALIFORNIA ENERGY COMMISSION ' CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 3 of 3) Projectname. pQSTAL ANNEX Date Prepared: 9/6/2014 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Docurnentation Author Name: ^|g^ FRITZSCHING Documentation Author Signature: company: |^p^ Architects, Inc. Signature Date: 9/Q/2OI4 3578 SOTH ST CEA/ HERS Certification identification (if applicable): City/State/Zip: SAN DIEGO, CA 92104 Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT 1 certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. 1 understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: ^^^^ FRITZSCHING Responsible Designer Signature: '• MPA ARCHITECTS Date Signed: 3578 SOTH ST License: city/state/zip: DIEGO, CA 92104 Phone: Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance HERS Provider: June 2013 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-03-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION ' ' CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 1 of 4) ProiectName: pQSTAL ANNEX Date Prepared: 9/5/2OI4 ALLOWED LIGHTING POWER (Chose Method) A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: El CONDITIONED spaces • UNCONDITIONED spaces A. SUMMARY TOTALS OF LIGHTING POWER ALLOWANCES • If using Complete Building Method for compliance, use only the total in column (a) as total allowed building watts. n If using Area Category Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b)as the total allowed building watts (a) (b) 1. Complete Building Method Allowed Watts. Documented in section B of NRCC-LTI-03-E (below on this page) 2. Area Category Method Allowed Watts. Documented in section C-l of NRCC-LTI-03-E (below on this page) 677 3. Tailored Method Allowed Watts. Documented in section A of NRCC-LTI-04-E 0 TOTAL ALLOWED BUILDING WATTS. Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 • Check here if building contains both conditioned and unconditioned areas. 677 TOTAL ALLOWED BUILDING WATTS. Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 • Check here if building contains both conditioned and unconditioned areas. B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE A B C D TYPE OF BUILDING (From §140.6 Table 140.6-B) WATTS PER (ft') X COMPLETE BLDG. AREA = ALLOWED WATTS X = X = Total Area: Total Watts. Enter Total Watts into section A, row 1 (Above on this page) C -1 AREA CATEGORY METHOD TOTAL LIGHTING POWER ALLOWANCES (C-2 plus C-3) Watts Total from section C-2 . 677 Total from section C-3 . 0 Total Watts. Enter Total Watts into section A, row 2 (Above on this page) . 677 Registration Number: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance Registration Date/Time: HERS Provider: June 2013 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-03-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION ' CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 2 of 4) Proiect Name: pQSTAL ANNEX Date Prepared: 9/5/2014 A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: • CONDITIONED spaces • UNCONDITIONED spaces C -2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE • Do not include portable lighting for offices. Portable lighting for offices shall be documented only in section B of NRCC-LTI-Ol-E. • Separately list lighting for each primary function area as defined in §100.1 of the Standards. A B X C D AREA CATEGORY (From §140.6 Table 140.6-C) WATTS PER (ft^) X AREA (ft^) ALLOWED WATTS Location in Building Primary Function Area per Table 140.6-C WATTS PER (ft^) X AREA (ft^) ALLOWED WATTS ZONE 1 All Others 0.60 X 1,128 677 X X X X X X X X X X X X X X X X X TOTALS 1,128 677 Enter sum total Area Category allowed watts Into section C-l of NRCC-LTI-03-E (this compliance form) 677 Registration Number: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance Registration Date/Time: HERS Provider: June 2013 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-03-E (Revised 06/13) site V CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 4 of 4) ProiectNa™: pQSTAL ANNEX Date Prepared: 9/5/2914 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: ^ISA FRITZSCHING Documentation Author Signature: ^"""'"^^ MPA Architects, Inc. Signature Date: 14 3578 SOTH ST CEA/ HERS Certification Identification (if appiicabie): city/state/zip: SAN DIEGO , CA 92104 Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT 1 certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices forthe building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 ofthe California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy ofthis Certificate of Compliance shall be made available with the building permit(s) issued forthe building, and made available to the enforcement agency for all applicable inspections. 1 understand that a completed signed copy ofthis Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: ^ig^ FRITZSCHING Responsible Designer Signature: company: MPA ARCHITECTS Date Signed: 3578 SOTH ST License: City/State/Zip: D\EGO, CA 92104 Phone: Registration Number: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance Registration Date/Time: HERS Provider: June 2013