HomeMy WebLinkAboutAMEND 2019-0003; CARLSBAD PACIFIC CENTER WCF; Administrative DeterminationCITY OF CARLSBAD
Administrative Permit -------------
CaseNoAM£AJn201q-O0O3
ExibitNo.''.4''-"J\1" Date i./f~'I f:J.o/'1 ~~~ .. ,
SITE INFORMATION
PROPERTY OWNER:
BROOKWOOD PACIFIC OFFICE I, LLC
705 PALOMAR AIRPORT RD. SUITE 110
CARLSBAD, CA 92011
CONTACT:
EVELYN MURPHY
(760) 575-7550
LATITUDE {NAD83):
33" 01· 11 .oo· N
33.12138889"
LONGITUDE {NAD83):
117" 19' 25.44" W
-117.32388889"
COUNTY:
SAN DIEGO
ZONING JURISDICTION:
CITY OF CARLSBAD
ZONING DISTRICT:
M-INOUSTRIAL
POWER COMPANY:
SDG&E
PARCEL NUMBER{S):
2101001700
SPRINT AGENT:
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
CONTACT: DRAKE ERICKSON
PHONE: 858.291.1823
SPRINT PROJECT MANAGER:
3730 FIFTH AVENUE
SAN DIEGO, CA 92103
CONTACT: MAEGAN MURPHY
PHONE: 619.985.6638
EMAIL: maegan.murphy@sprint.com
CONSTRUCTION MANAGER:
3730 FIFTH AVENUE
SAN DIEGO, CA 92103
CONTACT: MIKE SEBESTA
PHONE: 760.644.1027
EMAIL: michael.sebesto@sprint.com
•
AREA MAP
.. '
N
LOCATION MAP
,,"
•._
.· •·
_s12_ Paforna··· ·--·. ,,---rt·· -R2 .:, --"r r-,Jt"\IFPO -u ----···-·· . ----·-----.. i l _____ ,,, _ _,
.,..:,_, ·,~ ------------~---=--:;c· ,_i
,, '••>.i:;:;-, _
:~pa-1~0m~-ar..::.A1rpeft..-R-€!=·=· =-~=--=:::.!· ~~='!\ll
··-., -
Carlsbad
N
PROJECT: 82 MACRO UPGRADE
SITE NAME: PALOMAR AIRPORT & 1-5
SIT·E CASCADE: SD03XC143
SITE ADDRESS: 701 PALOMAR AIRPORT ROAD
CARLSBAD, CA 92009
SITE TYPE: ROOF
PROJECT DESCRIPTION
UPGRADE TO AN EXISTING SPRINT SITE:
• ANTENNAS {9 TOTAL)
1. REMOVE (3) EXISTING ANTENNAS
2. INSTALL (9) PANEL ANTENNAS
• RRH'S {18 TOTAL)
1. REUSE (3) EXISTING RRH'S
2. INSTALL ( 15) NEW RRH'S
• INSTALL (1) NEW 9712 LIGHTRADIO CABINET
• INSTALL (1) NEW JUNCTION BOX
INSTALL (1) FUTURE GROWTH CABINET
APPLICABLE CODES
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDmONS OF THE FOLLOWING
CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORmEs.
NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK
NOT CONFORMING TO THESE CODES:
• 2016 CALIF. ADMINISTRATIVE CODE
(INCL. TITLES 24 & 25)
• 2016 CALIFORNIA BUILDING CODES
• 2016 CALIFORNIA ELECTRICAL CODES
•2016 CALIFORNIA MECHANICAL CODES
•2016 CALIFORNIA PLUMBING CODES
•2016 CALIFORNIA FIRE CODES
• 2016 CALIFORNIA ENERGY CODES
• TIA-222-G STANDARD
• LOCAL BUILDING CODES
• CITY /COUNTY ORDINANCES
Know what's below.
Call before you dig.
www .call811.corn
SHEET NO:
T-1
SP-1
SP-2
A-1
A-2
A-3
A-4
A-5
D-1
0-2
0-3
0-4
E-1
DRAWING INDEX
SHEET TITLE
TITLE SHEET
SPRINT SPECIFICATIONS
SPRINT SPECIFICATIONS
SITE PLAN & EQUIPMENT LAYOUT . •c,, •.
LEGENDS, EQUIPMENT TABULAT)ON, AND ANTENNA LAYOUTS
BUILDING ELEVATIONS
BUILDING ELEVATIONS
BUILDING ELEVATIONS
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS
RF DATA
GROUNDING PLAN & DETAILS
AMEN[) J0l1-OOO3
PL.ANS PREPARED FOR: ---------,
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:---------.
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB #551-001
CONSULTANT:-----------,
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: ---------.
lviAR 21 2019
CiTY OF CARLSBAD
PLAN!\J!NG D\\/1S10!'-J
DRAWING NOTICE:----------.
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:------,----,,---,---,
DESCRIPTION DATE BY REV
SITE NAME:------------,
PALOMAR
AIRPORT & 1-5
SITE CASCADE:-----------,
SD03XC143
SITE ADDRESS:-----------,
701 PALOMARAIRPORTROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:----------,
TITLE SHEET
SHEET NUMBER:------------.
T-1
THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECIFICATIONS, INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY
THE CONTRACTOR.
CONTRACTOR SUPPLIED: SUPPLIER WILL SUPPLY ALL MINOR MATERIALS NECESSARY FOR PERFORMANCE OF SERVICES.
MINOR MATERIALS INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING (•MINOR MATERIALSj:
A. CONDUIT IN LENGTHS LESS THAN OR EQUAL TO 5 FEET;
B. WIRE;
C. BREAKERS;
D. GROUNDING CABLE;
E. ANTENNA AND LINE INSTALLATION HARDWARE;
F. CONDUIT CLAMPS;
G. CONDUIT CONNECTORS;
H. WEATHERPROOFING MATERIALS;
I. GROUNDING KITS;
J. HOISTING GRIPS;
K. SNAP-IN HANGERS WITH GROMMETS;
L. BUTTERFI.Y HANGER KITS;
M. COAX BLOCKS AND HARDWARE;
N. ANGLE ADAPTERS, U BOLTS, AND OTHER MISCELI.ANEOUS HARDWARE;
0. CROSSOVER PLATES;
P. RET CABLES
Q. PIPE MOUNTS, PIPE TO PIPE MOUNTS;
R. ICE BRIDGES IN LENGTHS LESS THAN OR EQUAL TO 5 FEET;
S. LIQUID TIGHT;
T. COMMON CONSUMABLES, INCLUDING BUT NOT LIMITED TO TAPES, SOLVENTS, ADHESIVES, LUGS,
NUTS, BOLTS, WASHERS, ETC.; AND
U. SUCH OTHER MINOR MATERIALS NOT SPECIFICALLY MENTIONED IN THIS SECTION BUT WHICH ARE
REASONABLE NECESSARY TO COMPLETE THE SERVICES.
SPRINT SUPPLIED:
A. BASE BAND UNITS;
B. BATTERY CABINETS;
C. MMBTS UNIT CABINETS;
D. RRH;
E. RETS;
F. ANTENNAS AND BRACKETS;
G. HFCS;
H. BATTERIES;
I. JUMPERS; AND
J. ANY OEM SPECIFIC EQUIPMENT(CARD, SHELF, OR CABINET) THAT NEEDS TO BE INSTALLED IN
OR NEXT TO MMBTS UNIT.
SECTION 01 100 -SCOPE OF WORK
THE WORK:
SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS, LATEST EDITION, AND
PORTIONS THEREOF.
PRECEDENCE:
SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR
WIRELESS SITES INCLUDING THE STANDARD CONSTRUCTION DETAILS FOR WIRELESS SITES AND THE
CONSTRUCTION DRAWINGS, INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE
PRECEDENCE.
SITE FAMILIARITY:
CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT
DOCUMENTS, FIELD CONDmONS AND DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION.
ON-SITE SUPERVISION:
THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES IN ACCORDANCE
WITH THE CONTRACT DOCUMENTS.
DRAWINGS. SPECIFICATIONS AND DETAILS REOUIRED AT JOBSITE:
THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS
AT THE JOBSITE FROM MOBILIZATION THROUGH CONSTRUCTION COMPLETION.
A. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND LABOR AS
REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. MODIFICATIONS MAY BE
REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE
INCLUDED AS PART OF THE WORK.
B. CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO
PROCEEDING WITH THE WORK.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED
OTHERWISE. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND
SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK.
C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM THE
CONSTRUCTION DOCUMENTS.
METHODS OF PROCEDURE {MOPS) FOR CONSTRUCTION:
CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN THE FOLLOWING INSTALLATION AND
COMMISSIONING MOPS.
A. TOP HAT
8. HOW TO INSTALL A NEW CABINET
C. BASE BAND UNIT IN EXISTING UNIT
D. INSTALLATION OF BATTERIES
E. INSTALLATION OF HYBRID CABLE
F. INSTALLATION OF RRH
G. CABLING
H. TS-0200 REV 4 -ANTENNA LINE ACCEPTANCE STANDARDS
I. SPRINT CELL SITE ENGINEERING NOTICE -EN 2012-001, REV 1.
J. COMMISSIONING MOPS
SECTION 01 200 -COMPANY FURNISHED MATERIAL AND EQUIPMENT
COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE
CONSTRUCTION DRAWINGS.
CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS
PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION DURATION.
CONTRACTOR RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR
CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN
ACCORDANCE WITH COMPANY PRACTICE.
SECTION 01 300 -CELL SITE CONSTRUCTION
NOTICE TO PROCEED:
NO WORK SHALL COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE
ISSUANCE OF WORK ORDER.
SITE CLEANLINESS:
CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND
TRASH. AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL REMOVE FROM THE SITE ALL
REMAINING RUBBISH, IMPLEMENTS, TEMPORARY FACILITIES, AND SURPLUS MATERIALS.
SECTION 01 400 -SUBMITTALS &: TESTS
ALTERNATES:
AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED
SHALL BE SUBMITTED TO SPRINTS CONSTRUCTION MANAGER FOR APPROVAL. SPRINT WILL
REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING. NO VERBAL APPROVALS WILL
BE CONSIDERED,
TESTS AND INSPECTIONS:
A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, INSPECTIONS AND
PROJECT DOCUMENTATION.
8. CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1. COAX SWEEPS AND FIBER TESTS PER TS-0200 REV 4 ANTENNA LINE ACCEPTANCE
STANDARDS.
2. AGL, AZIMUTH AND DOWNTILT PROVIDE AN AUTOMATED REPORT UPLOADED TO SITERRA USING
A COMMERCIAL MADE-FOR THE PURPOSE ELECTRONIC ANTENNA ALIGNMENT TOOL {MT).
INSTALLED AZIMUTH, CENTERLINE AND DOWNTILT MUST CONFORM WITH RF CONFIGURATION
DATA
3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY
WORK IDENTIFIED AS UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A
RESULT OF TESTING.
4. ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS.
C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT LIMITED TO THE
FOLLOWING;
1. AZIMUTH, DOWNTILT, AGL FROM SUNSIGHT INSTRUMENTS -ANTENNALIGN ALIGNMENT
TOOL {MT)
2. SWEEP AND FIBER TESTS
3. SCANABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED
EQUIPMENT
4. ALL AVAILABLE JURISDICTIONAL INFORMATION
5. PDF SCAN OF REDLINES PRODUCED IN FIELD
6. A PDF SCAN OF REDLINE MARK-UPS SUITABLE FOR USE IN ELECTRONIC AS-BUILT
DRAWING PRODUCTION
7. LIEN WAIVERS
8. FINAL PAYMENT APPLICATION
9. REQUIRED FINAL CONSTRUCTION PHOTOS
10. CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS
11. ALL POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA {SPRINTS
DOCUMENT REPOSITORY OF RECORD).
12. CLOSEOUT PHOTOGRAPHS:
o PROVIDE PHOTOGRAPHS OF FINAL PROJECT PER THE FOLLOWING UST. ADDmONAL
PHOTOGRAPHS MAY BE REQUIRED TO SUPPORT ACCEPTANCE PROCESSES
(i) MAIN HYBRID CABLE ROUTE (MINIMUM TWO PHOTOS)
{ii) PHOTOS OF EACH ANTENNA AND RRH
(iii) MANUFACTURERS NAME TAG FOR ALL SERIALIZED EQUIPMENT
(iv) PULL AND DISTRIBUTION BOXES INTERMEDIATE BETWEEN RRH AND MMBS {DOOR OPEN)
(v) MMBS CABINET WITH DOOR OPEN SHOWING MODIFICATIONS
{vi) POWER CABINET, DOORS OPEN, BATTERIES INSTALLED
(vii) BREAK OUT CYLINDERS
{viii) ASR SIGNAGE FOR SPRINT OWNED TOWERS
{ix) RADIATION EXPOSURE WARNING SIGNS
(x) PHOTOGRAPH FROM EACH SECTOR FROM APPROXIMATELY RAD CENTER OF ANY NEW
ANTENNA AT HORIZON.
b LOAD PHOTOS TO SITERRA PROJECT LIBRARY 15. IN 15 CREATE NEW CATEGORY; 2500MHz
DEPLOYMENT, AND SECTION; PERMANENT CONSTRUCTION. LABEL PHOTOS WITH SITE CASCADE
AND VIEW BEING DEPICTED. CAMERAS USED TO TAKE PHOTOGRAPHS SHALL GPS ENABLED
SUCH THAT THE GPS COORDINATES ARE INCLUDED IN THE PHOTO MEDIA-FILE INFORMATION.
COMMISSIONING:
PERFORM ALL COMMISSIONING AS REQUIRED BY APPLICABLE MOPS
INTEGRATION:
PERFORM ALL INTEGRATION ACTIVITIES AS REQUIRED BY APPLICABLE MOPS
SECTION 07 500 -ROOF CUTTING. PATCHING AND REPAIR
SUMMARY:
THIS SECTION SPECIFIES CUTTING AND PATCHING EXISTING ROOFING SYSTEMS WHERE CONDUIT
OR CABLES EXIT THE BUILDING ONTO THE ROOF OR BUILDING-MOUNTED ANTENNAS, AND AS
REQUIRED FOR WATERTIGHT PERFORMANCE. ROOFTOP ENTRY OPENINGS IN MEMBRANE ROOFTOPS
SHALL BE CONSTRUCTED TO COMPLY WITH LANDLORD, ANY EXISTING WARRANTY, AND LOCAL
JURISDICTIONAL STANDARDS.
1.4 SUBMITTALS:
A. PRE-CONSTRUCTION ROOF PHOTOS: COMPLETE A ROOF INSPECTION PRIOR TO THE
INSTALLATION OF SPRINT EQUIPMENT ON ANY ROOFTOP BUILD. AT A MINIMUM INSPECT AND
PHOTOGRAPH
(MINIMUM 3 EA.) ALL AREAS IMPACTED BY THE ADDITION OF THE SPRINT EQUIPMENT.
8. PROVIDE SIMILAR PHOTOGRAPHS SHOWING ROOF CONDmONS AFTER CONSTRUCTION {MINIMUM
3 EA.)
C. ROOF INSPECTION PHOTOGRAPHS SHOULD BE UPLOADED WITH CLOSEOUT PHOTOGRAPHS.
SECTION 09 900 -PAINTING
QUALITY ASSURANCE:
A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE
MANUFACTURERS WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE
YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
B. COMPLY WITH ALL ENVIRONMENTAL REGULATIONS FOR VOLATILE ORGANIC COMPOUNDS.
MATERIALS:
A. MANUFACTURERS: BENJAMIN MOORE, ICI DEVOE COATINGS, PPG, SHERWIN WILLIAMS OR
APPROVED EQUAL. PROVIDE PREMIUM GRADE, PROFESSIONAL -QUALITY PRODUCTS FOR
COATING SYSTEMS.
PAINT SCHEDULE:
A. EXTERIOR ANTENNAE AND ANTENNA MOUNTING HARDWARE: ONE COAT OF PRIMER AND TWO
FINISH COATS. PAINT FOR ANTENNAE SHALL BE NON-METALLIC BASED AND CONTAIN NO
METAWC PARTICLES. PROVIDE COLORS AND PATTERNS AS REQUIRED TO MASK APPEARANCE
OF ANTENNAE ON ADJACENT BUILDING SURFACES AND AS ACCEPTABLE TO THE OWNER.
REFER TO ANTENNA MANUFACTURER'S INSTRUCTIONS WHENEVER POSSIBLE.
B. ROOF TOP CONSTRUCTION: TOUCH UP -PREPARE SURFACES TO BE REPAIRED. FOLLOW
INDUSTRY STANDARDS AND REQUIREMENTS OF OWNER TO MATCH EXISTING COATING AND
FINISH.
PAINTING APPLICATION:
1. INSPECT SURFACES, REPORT UNSATISFACTORY CONDITIONS IN WRITING; BEGINNING
WORK MEANS ACCEPTANCE OF SUBSTRATE.
2. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FOR
PREPARATION, PRIMING AND COATING WORK. COORDINATE WITH WORK OF OTHER
SECTIONS.
3. MATCH APPROVED MOCK-UPS FOR COLOR, TEXTURE, AND PATTERN. RE-COAT OR
REMOVE AND REPLACE WORK WHICH DOES NOT MATCH OR SHOWS LOSS OF
ADHESION.
4. CLEAN UP, TOUCH UP AND PROTECT WORK.
TOUCHUP PAINTING:
1. GALVANIZING DAMAGE AND ALL BOLTS AND NUTS SHALL BE TOUCHED UP AFTER
TOWER ERECTION WITH "GALVANOX," "DRY GALV," OR "ZINC-IT."
2. FIELD TOUCHUP PAINT SHALL BE DONE IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
3. ALL METAL COMPONENTS SHALL BE HANDLED WITH CARE TO PREVENT DAMAGE TO
THE COMPONENTS, THEIR PRESERVATIVE TREATMENT, OR THEIR PROTECTIVE
COATINGS.
SECTION 11 700 -ANTENNA ASSEMBLY, REMOTE RADIO UNITS AND CABLE
INSTALLATION
SUMMARY:
THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRH, AND CABLE EQUIPMENT,
INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE.
ANTENNAS AND RRH:
THE NUMBER AND TYPE OF ANTENNAS AND RRH TO BE INSTALLED IS DETAILED ON THE
CONSTRUCTION DRAWINGS.
HYBRID CABLE:
HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH SITE.
CABLE SHALL BE INSTALLED PER THE CONSTRUCTION DRAWINGS AND THE APPLICABLE
MANUFACTURER'S REQUIREMENTS.
JUMPERS AND CONNECTORS:
FURNISH AND INSTALL 1/2" COAX JUMPER CABLES BETWEEN THE RRH AND
ANTENNAS. JUMPERS SHALL BE TYPE LDF 4, FLC 12-50, CR 540, OR FXL 540.
SUPER-FLEX CABLES ARE NOT ACCEPTABLE. JUMPERS BETWEEN THE RRH AND ANTENNAS
OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC, OUTDOOR
RATED COAXIAL CABLE. DO NOT USE SUPERFLEX OUTDOORS. JUMPERS SHALL BE FACTORY
FABRICATED IN APPROPRIATE LENGTHS WITH A MAXIMUM OF 4 FEET EXCESS PER JUMPER
AND HAVE CONNECTORS AT EACH END, MANUFACTURED BY SUPPLIER. IF JUMPERS ARE
FIELD FABRICATED, FOLLOW MANUFACTURER'S REQUIREMENTS FOR INSTALLATION OF
CONNECTORS
REMOTE ELECTRICAL TILT (RET) CABLES:
MISCELLANEOUS:
INSTALL SPLITTERS, COMBINERS, FILTERS PER RF DATA SHEET, FURNISHED BY SPRINT.
ANTENNA INSTALLATION:
THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH THE
INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH, AND FEED
ORIENTATION INFORMATION SHALL BE A DESIGNATED ON THE CONSTRUCTION DRAWINGS.
CONTINUE SHEET SP-2
~-----------------------------------------~
PLANS PREPARED FOR:--------
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:---------
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB #551-001
CONSULTANT:-----------.
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO. CA 92130
858.799.7850
ENGINEERING LICENSE: --------
DRAWING NOTICE:---------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:-----------
DESCRIPTION BY REV
90% CD's en. A
REVISED 90% CD's 00: B
SITE NAME:-----------
PALOMAR
AIRPORT & 1-5
SITE CASCADE:-----------.
SD03XC143
SITE ADDRESS:----------
701 PALOMAR AIRPORT ROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:---------.
SPRINT SPECIFICATIONS
SHEET NUMBER:----------
SP-1
A. THE CONTRACTOR SHALL PosmoN THE ANTENNA ON TOWER PIPE MOUNTS so THAT
THE BOTTOM STRUT IS LEVEL. THE PIPE MOUNTS SHALL BE PLUMB TO WITHIN
1 DEGREE.
8. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS
INDICATED ON THE DRAWINGS.
HYBRID CABLES INSTALLATION:
A. THE CONTRACTOR SHALL ROUTE, TEST, AND INSTALL ALL CABLES AS INDICATED ON
THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS.
8. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE
MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII.
C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING
AND INSTALLATION.
1. FASTENING MAIN HYBRID CABLES: ALL CABLES SHALL BE PERMANENTLY FASTENED
TO THE COAX LADDER AT 4' -0" OC USING NON-MAGNETIC STAINLESS STEEL CLIPS.
2. FASTENING INDMDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE
(MEDUSA), WITHIN THE MMBS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES:
a. FIBER: SUPPORT FIBER BUNDLES USING ½" VELCRO STRAPS OF THE REQUIRED
LENGTH @ 18" OC. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND
SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR
APPROVED EQUAL.
b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES
TO BE UV STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12,000 PSI
AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL.
3. FASTENING JUMPERS: SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES
USING STAINLESS STEEL TIE WRAPS OR STAINLESS STEEL BUTTERFLY CLIPS.
4. CABLE INSTALLATION:
a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE, NOTIFY THE
CONSTRUCTION MANAGER.
b. CABLE ROUTING: CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE
LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOP AS INDICATED ON
THE DRAWINGS. AVOID TWISTING AND CROSSOVERS.
c. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURES
RECOMMENDED MAXIMUM BEND RADIUS.
5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE
GROUNDED AS INDICATED ON DRAWINGS.
6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN TS
0200 REV 4.
7. HYBRID CABLE LABELING: INDMDUAL HYBRID AND DC BUNDLES SHALL BE LABELED
ALPHA-NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE -EN
2012-001, REV 1
WEATHERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND
KITS:
A. ALL FIBER & COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED.
8. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST
BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND
INDUSTRY BEST PRACTICES.
1. COLD SHRINK: ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A
DOUBLE WRAP OF 2" ELECTRICAL TAPE EXTENDING 2" BEYOND
TUBING. PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL.
2. SELF-AMALGAMATING TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF
SELF-AMALGAMATING TAPE 2" BEYOND CONNECTOR. APPLY A SECOND WRAP OF
SELF-AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP
OF 2" WIDE ELECTRICAL TAPE EXTENDING 2" BEYOND THE SELF-AMALGAMATING
TAPE.
3. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED.
4. OPEN FLAME ON JOB SITE IS NOT ACCEPTABLE
SECTION 11 800 -INSTALLATION OF MULTIMODAL BASE STATIONS
(MMBS) AND RELATED EQUIPMENT
SUMMARY:
A. THIS SECTION SPECIFIES MMBS CABINETS, POWER CABINETS, AND INTERNAL EQUIPMENT
INCLUDING BY NOT LIMITED TO RECTIFIERS, POWER DISTRIBUTION UNITS, BASE BAND
UNITS, SURGE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE
COMPANY FOR INSTALLATION BY THE CONTRACTOR {OFCI).
8. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND
PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR
NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE APPLICABLE
INSTALLATION MOPS.
C. COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS
DC CIRCUIT BREAKER LABELING
A. LABEL CIRCUIT BREAKERS ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE -EN
2012-001, REV 1.
SECTION 11 800 -INSTALLATION OF MULTIMODAL BASE STATIONS
(MMBS) AND RELATED EQUIPMENT
SUMMARY:
A. THIS SECTION SPECIFIES MMBS CABINETS, POWER CABINETS, AND INTERNAL EQUIPMENT
INCLUDING BY NOT LIMITED TO RECTIFIERS, POWER DISTRIBUTION UNITS, BASE BAND
UNITS, SURGE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE
COMPANY FOR INSTALLATION BY THE CONTRACTOR (OFCI).
8. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND
PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR
NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE APPLICABLE
INSTALLATION MOPS.
C. COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS
SUPPORTING DEVICES:
A. MANUFACTURED STRUCTURAL SUPPORT MATERIALS: SUBJECT TO COMPLIANCE WITH
REQUIREMENTS, PROVIDE PRODUCTS BY THE FOLLOWING:
1. ALLIED TUBE AND CONDUIT
2. 8-LINE SYSTEM
3. SUNISTRUT DIVERSIFIED PRODUCTS
4. THOMAS & BETTS
8. FASTENERS: TYPES, MATERIALS, AND CONSTRUCTION FEATURES AS FOLLOWS:
1. EXPANSION ANCHORS: CARBON STEEL WEDGE OR SLEEVE TYPE.
2. POWER-DRIVEN THREADED STUDS: HEAT-TREATED .STEEL, DESIGNED SPECIFICALLY
FOR THE INTENDED SERVICE.
3. FASTEN BY MEANS OF WOOD SCREWS ON WOOD.
4. TOGGLE BOLTS ON HOLLOW MASONRY UNITS.
5. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY.
6. MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING-TENSION CLAMPS ON
STEEL
7. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE
PERMITTED.
8. DO NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS
TO STEEL STRUCTURES.
9. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS.
SUPPORTING DEVICES:
A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND
PERMANENTLY IN ACCORDANCE WITH NEC.
8. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES.
C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, FASTEN ELECTRICAL ITEMS AND
THEIR SUPPORTING HARDWARE SECURELY TO THE STRUCTURE IN ACCORDANCE WITH
THE FOLLOWING:
D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT
OF THE PROOF TEST LOAD.
E. USE VIBRATION AND SHOCK-RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE
SLABS.
ELECTRICAL IDENTIFICATION:
A. UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET,
INSIDE DOORS OF AC PANEL BOARDS WITH ANY CHANGES MADE TO THE AC SYSTEM.
8. BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE
CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANELBOARD.
SECTION 26 200 -ELECTRICAL MATERIALS AND EQUIPMENT
CONDUIT:
A. RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS
ABOVE GROUND AND IN UNFINISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN
CONCRETE. RIGID CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC
EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS. CONDUIT SHALL BE
PRODUCED TO ANSI SPECIFICATIONS C80.1, FEDERAL SPECIFICATION WW-C-581 AND
SHALL BE LISTED WITH THE UNDERWRITERS' LABORATORIES. FITTINGS SHALL BE
THREADED -SET SCREW OR COMPRESSION FITTINGS WILL NOT BE ACCEPTABLE. RGS
CONDUITS SHALL BE MANUFACTURED BY AWED, REPUBLIC OR WHEATLAND.
8. UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE (PVC) SUITABLE
FOR DIRECT BURIAL AS APPLICABLE. JOINTS SHALL BE BELLED, AND FLUSH SOLVENT
WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE
CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL.
C. TRANSmONS BETWEEN PVC AND RIGID (RGS) SHALL BE MADE WITH PVC COATED
METALLIC LONG SWEEP RADIUS ELBOWS.
D. EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED SPACES
CONCEALED IN WALLS AND CEILINGS. EMT SHALL BE MILD STEEL, ELECTRICALLY
WELDED, ELECTRO-GALVANIZED OR HOT-DIPPED GALVANIZED AND PRODUCED TO ANSI
SPECIFICATION C80.3, FEDERAL SPECIFICATION WW-C-563, AND SHALL BE UL LISTED.
EMT SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND, OR APPROVED
EQUAL. FITTINGS SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS SHALL
NOT BE ACCEPTABLE.
E. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR FINAL CONNECTION TO
EQUIPMENT. FITTINGS SHALL BE METALLIC GLAND TYPE COMPRESSION FITTINGS,
MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM. SET SCREW CONNECTIONS SHALL NOT
BE ACCEPTABLE. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED
6-FEET. LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC.
MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, ANACONDA METAL HOSE OR
UNIVERSAL METAL HOSE, OR APPROVED EQUAL.
F. MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH {21MM).
HUBS AND BOXES:
A. AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED
HUBS PROVIDE METAWC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED.
HUB SHALL INCLUDE LOCKNUT AND NEOPRENE 0-RING SEAL. PROVIDE IMPACT
RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION.
B. CABLE TERMINATION FITTINGS FOR CONDUIT
1. CABLE TERMINATORS FOR RGS CONDUITS SHALL BE TYPE CRC BY 0-Z/GEDNEY OR
EQUAL.
2. CABLE TERMINATORS FOR LFMC SHALL BE ETCO -CL2075; OR MADE FOR THE
PURPOSE PRODUCTS BY ROXTEC.
C. EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE
PLATED CAST ALLOY, HEAVY DUTY, WEATHERPROOF, DUST PROOF, WITH GASKET, PLATED
IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE-HINDS WAS SERIES
OR EQUAL.
D. CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKETED
COVERS. OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR
THE APPLICATION. PROVIDE CROUSE-HINDS FORM 8 OR EQUAL.
E. MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN, SQUARE •D•,
CROUSE-HINDS, COOPER, ADALET, APPLETON, 0-2 GEDNEY, RACO, OR APPROVED
EQUAL.
SUPPLEMENTAL GROUNDING SYSTEM
A. FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM AS INDICATED ON THE
DRAWINGS. SUPPORT SYSTEM WITH NON-MAGNETIC STAINLESS STEEL CLIPS WITH
RUBBER GROMMETS. GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE, SIZES
AS INDICATED ON THE DRAWINGS. PROVIDE STRANDED OR SOLID BARE OR INSULATED
CONDUCTORS AS INDICATED.
B. SUPPLEMENTAL GROUNDING SYSTEM: ALL CONNECTIONS TO BE MADE WITH CAD WELDS,
EXCEPT AT EQUIPMENT USE LUGS OR OTHER AVAILABLE GROUNDING MEANS AS
REQUIRED BY MANUFACTURER; .AT GROUND BARS USE TWO HOLE SPADES WITH NO OX.
C. STOLEN GROUND-BARS: IN THE EVENT OF STOLEN GROUND BARS, CONTACT SPRINT CM
FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS.
EXISTING STRUCTURE:
A. EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS, RECEPTACLES, SWITCHES,
DEVICES, BOXES, AND OTHER EQUIPMENT THAT ARE NOT TO BE UTILIZED IN THE
COMPLETED PROJECT SHALL BE REMOVED OR DE-ENERGIZED AND CAPPED IN THE
WALL, CEILING, OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE. WALL, CEILING,
OR FLOOR SHALL BE PATCHED TO MATCH THE ADJACENT CONSTRUCTION.
CONDUIT AND CONDUCTOR INSTALLATION:
A. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED
STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE
WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN
CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES.
CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT
OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER,
PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT
SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE
TEMPORARILY CAPPED TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING.
CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON
BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND
INSIDE.
B. CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE.
PLANS PREPARED FOR:----------.
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:---------,
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB #551-001
CONSULTANT:-----------,
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: --------.
DRAWING NOTICE:------------.
TH ESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:------.---.---.----,
DESCRIPTION BY REV
90% CD's en. A
REVISED 90% CD's 00: B
SITE NAME:------------,
PALOMAR
AIRPORT & 1-5
SITE CASCADE:------------,
SD03XC143
SITE ADDRESS:-----------,
701 PALOMAR AIRPORT ROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:----------,
SPRINT SPECIFICATIONS
SHEET NUMBER:----------,
SP-2
-----_______ , _____ , -------------------------------------------------------·---------
NOlE:
SITE PLAN IS PREI.IMINARY AND DONE
WITHOUT lHE BENEFIT OF A SURVEY.
APPROXIMATE LOCATION
OF EXISTING PROPERIY
LINE (lYP.)
. '
EXISTING
BUILDING (lYP.)
SECTOR 'C'
AZIMUTH
190°
I
~I I
I
I
I
SITE PLAN
I
J
I
I
I
[J __
SECTOR 1 A'
AZIMUTH
10· ..._.
---..... ---~
I
I
~
EXISllNG/NEW SPRINT
EQUIPMENT MOUNTED ON
EXISIING BUILDING ROOFlOP
@
SECTOR 1 8'
AZIMUTH f
100· ~
z
SCALE: 1--1 I · L--,,j
1/64"=1'-o'" 0 321 64' 1
EXISTING VERIZON
PANEL ANTENNAS
~ (E) &: NEW SPRINT PANEL
A-2 -ANTENNAS LOCATION (ALPHA
EXISTING
CINEA PANEL
• •• •• •• •• •• •• ,._• •• •• ♦ •• ♦ ...
NEW SPRINT ~
JUNCTION BOX~
••••••• • •••••• •
• • •
(E) &: NEW SPRINT PANEL ~
ANTENNAS LOCATION (BEfA) 7-2=
[
EXISTING T-MOBILE
PANEL ANTENNAS
••••••••••
DODD
I•. ~ISTING ROOFTOP . / ACCESS HATCH . /
I~ ~II ,(~EC~ 111 00
00
~ {E) & NEW SPRINT e} EQUIPMENT LOCATION
~--··················· • • • • • • • • • • • • • •
•• . ......
ROOF PLAN
-------------
EXISTING SPRINT
TELCO CABINET"
--/,.,.,,--"'"'
/
,l
I I I
I I I I
NEW FUTURE LJ"-...
GROWTH CABINET"~
EQUIPMENT LAYOUT
-----------------------------~---------------------~-------------------------------------------
(E) ECU
EXISTING VERIZON
PANEL ANTENNAS
EXISTING
BUILDING
r-·----. -------
EXISTING SPRINT
BBU CABINET"
(E) ECU 00
00
EXISTING SPRINT
CABLE lRAY {IYP.)
EXISTING SPRINT
8TS CABINET"
0
EXISTING RF FRIENDLY
SCREEN WALL W/ DIAGONAL
SUPPORTS BRACES (lYP.)
1-1 J L o"
EXISTING SPRINT
STm ROOFTOP SLED
16' 2
EXISTING SPRINT
HYBRIFLEX CABINET"
Qi------------'
0
NEW 9712~
UGHTRADI0~
EXISTING SPRINT
CABLE lRAY
\_ EXISTING SPRINT
COX-PCS BOX
EXISTING SPRINT
AC PANEL
Sr.ALE: 1111 I 3/4"=1'-o'" 0 1' 3
PLANS PREPARED FOR:----------.
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:----------
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB #551-001
CONSULTANT:-------------,
MD7, UC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: ---------,.
DRAWING NOTICE:------------,
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:------------.---.
DESCRIPTION BY REV
90% CD's CTL A
REVISED 90% CD's CKE B
SITE NAME:--------------.
PALOMAR
AIRPORT & 1-5
SITE CASCADE:-------------.
SD03XC143
SITE ADDRESS:-------------.
701 PALOMAR AIRPORT ROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:----------
SITE PLAN &
EQUIPMENT LAYOUT
SHEET NUMBER:------------
A-1
LEGENDS:
,.. -.,) PANEL ANTENNA #1 (:_1) 1!11 PANEL ANTENNA #2 (:..1)
RRH #2 ~ '\Bl '•44 j. RRH #3 ~ '\Bl
EXISTING AND NEW EQUIPMENT TABULATION (TOTAL COUNT)
lHIS PROJECT ACCOUNTS FOR lHE EQUIPMENT LISTED ON lHE TABLE BEi.OW. lHIS DRAWING AND CALCUIATIONS DO
NOT SUPERCEIJE PREVIOUS CALCULATION PREPARED BY lHE ORIGINAL ARCHITECT OR ENGINEER
EXISTING & NEW EQUIPMENT EXISTING REMOVE NEW TOTAL
(TOTAL coul'II) ~ij,// 1/////2: 1/////2 ~///1/,
PANEL ANTENNA #1 0 0 6 6
PANEL ANTENNA #2 0 0 3 3
RRH #1 3 0 3 6
RRH #2 0 0 6 6
RRH #3 0 0 3 6
NOIT: EQUIPMENT LESS lHAN 50 LBS ARE CONSIDERED MISCEl.lANEOUS ITEMS AND ARE NOT SHOWN
WEIGHT (APPROX.) LBS
PER UNIT TOTAL
C:1/'~ 07/2:
66.0 396
103.7 311.1
59.5 357
53 318
44.1 264.6
TOTAL: 1646.7
LEGENDS &. EQUIPMENT TABULATION
DETAIL NOT USED
FIBER/COAX CABLES
SECTOR TYPE LENGTH (FEET)
FIBER ±100'
FIBER ±130'
BETA
FIBER ±125'
GAMMA
NOTE: CABLE LENGTHS ARE APPROXIMAlE AND
HA\IE NOT BEEN F1E1.D \IERIFlEO BY INFINIGY
NO SCALE
NO SCALE
3
4
SECTOR 'A'
AZIMUTH t
10°
EXISTING FRP
SCREEN ENCLOSURE
SECTOR 'C'
f AZIMUTH
' 190°
1------EXIISTING CABLE
lRAY (l'fP.) ---.
RRH PER SECTOR
REMAINING: 1
RELOCATING: 0
REMOVING: 0
TOTAL: 1
EXISTING PANEL
ANlENNA BY
OlHER (TYP .)
PANEL ANTENNA PER SECTOR ~ EXISTING FRP
SCREEN ENCLOSURE
REMAINING: 0
RELOCATING: 0
REMOVING: 1
TOTAL: 1
SECTOR 'B'
AZIMUTH
100° ..._.
EXISTING FRP
SCREEN ENCI..OSURE
N
EXISTING ANTENNA LAYOUT 1
SECTOR 'A'
AZIMUTH t
1 o·
5'-f!'
\NEW STEEL TUBE FRAME TO MATCH
EXISTING TYPE AND SlRUCTURE.
COMIRACTOR TO VERIFY MATERIALS AND
METHODS PRIOR TO CONSTRUCTION.
EXISTING FRP
SCREEN ENCLOSURE
EXISTING CABLE
TRAY (l'fP.)--..../
EXISTING SCREEN WALL
DIAGONAL SUPPORTS (l'fP.)
SECTOR 'c'
f AZIMUTH
' 190°
6'-ft'
5'-f!'
PANEL ANTENNA PER SECTOR
REMAINING: 0
REI.OCAlED: 0
NEW: 3
TOTAL: 3
RRH #3 (l'fP. OF
(2) PER SEClOR)
6'-ft'
ANTENNA #2 (l'fP.
OF (2) PER SECTOR)
EXISTING CABLE
lRAY (l'fP.)
PROPOSED ANTENNA LAYOUT
EXISTING FRP
SCREEN ENCLOSURE
ANTENNA #1 (l'fP.
OF (2) PER SEClOR)
SECTOR 'B'
AZIMUTH
100· ..._.
RRH #1 & #2 (l'fP. OF
(2) EACH PER SECTOR)
FOR NOKIA 2500MHz
RRH MOUNTING, SEE
SHm D-3, DETAIL 3
\_ EXISTING FRP
SCREEN ENCLOSURE
N
SCALE: I t -I -1 I 2
3/8"=1'-0" 0 1' 2· 3'
PLANS PREPARED FOR:---------
' Sprint fl>
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:---------
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB 11551-001
CONSULTANT:------------
MD7, LLC
10590 WEST OCEAN AIR DR 11300
SAN DIEGO, CA 92130
858.799.7850
: ENGINEERING LICENSE: ---------
DRAWING NOTICE:----------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:------------
DESCRIPTION DATE BY REV
90% CD's C1l A
REVISED 90% CD's CKE B
SITE NAME:------------
PALOMAR
AIRPORT & 1-5
SITE CASCADE:-----------
SD03XC143
SITE ADDRESS:-----------
701 PALOMARAIRPORTROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:---------
& ANTENNA LAYOUTS
LEGENDS, EQUIP TABULA.
SHEET NUMBER:-----------
A-2
RRH PER SECIDR
REMAINING: 1
RELOCATING: 0
REMOVING: 0
EXISTING/NEW TOTAL:
1~
SPRINT EQUIPMENT~
"' ' if r---,---T"" . . -,
I I I I I I I • I I I I I I I IX! Q. I I I I I I I I er:.
' I I I I I I I • LL. ~ I I I I I I I r--I I I I I I I ,,
I I I I I I I
' .
I
I '
-----f-----------------r --·-----~ ------~
-----------~ ----... -~--------------.---------
I I I
I I I
--------' -------1···· ~-------------------------------------------------------------~----------
I I I
I I I I
-------------~ ---C------------------~ --I------I-----. ----------------··· --------I--------------
I I I I
EXISTING SOUTH BUILDING ELEVATION {GAMMA)
RRH PER SECTOR --
REMAINING: 1
RELOCAIBl: 0
NEW: 5
EXISTING/NEW TOTAL: 6
SPRINT EQUIPMENT~ ~ ~
r---,---.-
i
-,
I I I I I I • I I I I I I I IX! Q. I I I I I I I I er:. I I I I I I I • LL. I I I I I I I r--I I I I I I I ,. I I I I I I I
I -I I
I
---.----------------------------i------------j-------------c---~ -------------~ -----~--
I
I I I I I
I I I
-----------------------t---------->-------------------------. ------------------
--. --~ --------------. -----,-----------~ 1-------
I I
I I
I I
------0 ------' ----------------------------t-------~ ------------~
I I I
PROPOSED SOUTH BUILDING ELEVATION {GAMMA)
PANA ANTENNA PER SECToR
REMAINING: 0
RELOCATING: 0
REMOVING: 1
TOTAL: 1 TOP OF EXISTING FRP SCREEN. ±46'-s·
/GAMMA SECTOR / y RAD CENTER OF EXISTING ANTENNAS. ±43'-3" ______________ __/
TOP OF EXISTING ROOF. ±38'-9"
-----~ -
------------~--~ ---------------r---------
i--EXISTING BUILDING
--i----------~ -------------.--------i-------------I-
GROUND REF. o·-o·
NO SCALE
-PMEI. ANTENNA PER SECTOR
REMAINING: 0 @@ RELOCAIBl: 0
NEW: 3 1H1H TOTAL: 3 I,, ,,,_ .. ., ., """ TOP OF EXISTING FRP SCREEN. ±46"-5"
r>NTENNA #2 {TYP. OF (1) PER SECTOR) / c RAD CENTER OF PROPOSEO ANIENNAS. ±43'-3"
________ __/ ---------
--"-----.... GAMMA SECTOR l --
TOP OF EXISTING ROOF. ±38'-9"
--' -~ ------------------
----------------------· .. -------
-----------------, --------'--------
--------------------~---~------
----EXISTING BUILDING
--------~ --------------------____ .__ ---
--------~ --------
GROUND REF. 0'-0"
NO SCALE
_,
_,
_,
1
_,
_,
_,
2
PLANS PREPARED FOR:----------.
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:-----------,
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CAUFORNIA 92630
JOB #551-001
CONSULTANT:-------------,
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: -----------,
DRAWING NOTICE:-----------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS: ----------,--"T"--,
DESCRIPTION DATE BY REV
90% CD's Cll A
REVISED 90% CD's CKE B
SITE NAME:--------------,
PALOMAR
AIRPORT & 1-5
SITE CASCADE:-------------.
SD03XC143
SITE ADDRESS:-------------.
701 PALOMARAIRPORTROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:------------.
EAST ELEVATION
SHEET NUMBER:-------------.
A-3
RRH PER SECTOR
REMAINING: 1
RELOCATING: 0
REMO'IING: 0
lOTAL; 1\
BEfA SECTOR~ \ /~SECTOR /
~------~i----------....::S...C--, ___ I',,-____,,_\ __ ,--: ---.--.---.---~H'+-, ---r..,£,
: CXl a.. --------------------~ I I 0:: I • LL.
I ~
PANEi, ANTENNA PER SECTOR
REMAINING: 0
REI..OCATING: 0
REMOVING: 1
TOfAL; 1
TOP OF EXISTING FRP SCREEN. ;i:46' -5" 0 .
RAD CENTER OF EXISTING ANTENNAS. ;1:43' -3" 0 ,
I
' 10P OF EXISTING ROOF. :1:38' -9" 0 .
I
1--. +.-_-. -I--+--+-t-===11=-:t=:-rc-c:l::r--:::: .. _=t==l=-'-::j::··=·cc ···=.j··· 1-=:c::i-=..c.:.:J...=cc:.....!,::.=c......j::: __ ----= ___ = -::-_:.:.:_:: -...:=---.. -+-_-.-+---1---------1------___ , ----~ -1------------· --_____ , __ _
-------------------------------cc:::=l: . ....=-=t-.....:::::::t.....c:=l-cc:.....=t==t-=1=-:t--t----::::r-:::t--::::=I · ·· · . -----1----. ----•. --
I
__ ,, _______ ·-·-·· __________ ,, ___ +---1-_________ ,-.----+--l---+--/---1----t---t---+---r--+--+------------------· -I---1--------+------l --l--+------l--+----1---1-1---+--+--+------l---t---f---t--+---11---·-+--l--t----l-----------,1---+---I--+----l
-------------------t---t--f----j-------------.. ------------·
-------EXISTING BUILDING
I
l===l===l==t:::::~~-:--~---:_ ___ --. +_-_-t---t--t--t-------_ --
-I-------
-
--
--------I-------------
f-· -=-=1=~=-=t=:::t::=1==1=+==1==1=.1=,-=1-= ---------~---------I-------~t===t==t==:J:==11=:-:i==-
I GROUND REF. o· -o· 0
EXISTING NORTH BUILDING ELEVATION {BETA) NO SCALE
RRH PER SEcrOR
REMAINING: 1 eAtlEL ANTENNA fEB Sf;r.mR
RB.OCAlED: 0 REMAINING: 0 @@ NEW: 5 REI.OC6.TED: 0 ;-· {!'IP. OF (2) PER SECfOR) TOTAL; 6 NEW: 3 1H1H TOP OF EXISTING FRP SCREEN. ±46'-511 0 TOTAL; 3
~@ NfilNNA #2 (lYP. OF (1) PER SECTOR) / 'o=,'ii:,'""iH
' 0 c I RAD CENTER OF PROPOSED ANTENNAS. ;1:43'-3" 0 I I • --------------~ I CXl a.. ' I 0:: I . I BEfA SECTOR . LL. ALPHA SECTOR ~ I T T T T ! 10P OF EXISTING ROOF. ±38'-g• 0
I
-. .. -----------. ----·····. .. --. --f-.. -----------~ .~ ---1------------------
I
I
I
----------------------.. -----· -------------------~ ----------------------·· -··· ---·· --,---------------------·· ~·· --------------~---·----~.
------EXISTING BUILDING
I
I
·---------.. ------------------------··--------------------------------->-------------------f-----------c -----~--~. --------------------------------I----------
I GROUND REF. 0'-011
PROPOSED NORTH BUILDING ELEVATION {BETA) NO SCALE
1
2
PL.ANS PREPARED FOR: ----------.
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
Pl.ANS PREPARED BY:----------
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB #551-001
CONSULTANT:-------------.
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: ----------.
DRAWING NOTICE:-----------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:-------,----,------.
DESCRIPTION BY REV
90% CD's Cll A
REVISED 90% CD's CKE B
SITE NAME:---------------.
PALOMAR
AIRPORT & 1-5
SITE CASCADE:------------
SD03XC143
SITE ADDRESS:-------------.
701 PALOMAR AIRPORT ROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:----------
BUILDING ELEVATIONS
SHEET NUMBER:------------.
A-4
----------------~------------------------------------------------------------------------------------------
RRH PER SECTOR PANEL ANTENNA PER SECTOR
REMAINING: 1 REMAINING: 0
RELOCATING: 0 RELOCATING: 0
REMOVING: 0 REMOVING: 1
TOTAL: 1 TOTAL: 1-~
~---'lOP OF EXISllNG FRP SCREEN. ±46' -s• ~
BETA SECTOR~ /
r-------------.---------------------------------,-------~,-,---+-----r------.------------\----/-/-ALP~HA-SECTO __ R ___ ~/ ' ~ ~ • V. { RAD CENTER OF PROPOSED ANTENNAS. ±-13'-3" ~
co Q. i ------------------1 0::: ,
-IL. r--
TOP OF EXISTING ROOF. ±38' -9" ~
--------t-=i==l===ll==l==l==+·.::c _------------------
---=t==t:= L______ . ----·+==J==t===l==t==l==-1~ -----
-------------
--------------C--l--+---' -------EXISTING BUILDING
l===l=-±--±c=L·-c_j__:=:=_-J_~t-:-::---t----,-,f-:==l===I=-=-cc --------------
---.,. --"' -. ---------------------------..... . -_---:_ --+=+==J===t:=-::.:J::==1==1=:::t===t=:J:==!===ll==!===J: CCC
GROUND REF. O' -o" 0
EXISTING NORTH-EAST BUILDING ELEVATION (ALPHA) NO SCALE 1
ANTENNA #1 (1'IP OF (2) PER SECTOR) .
RRH PER $ECIOR
REMAINING: 1 eN:lEL ANTENNA PER SECTOR
Rll.OCATED: 0 REMAINING: 0 ~ ANTENNA #2 (T'IP. OF (1) PER SECTOR)
NEW: 5 RELOCATED: 0
TOTAL: 6 NEW: 3 1H1H
~ TOTAL: 3
/ ~
TOP OF EXISTING FRP SCREEN. ±46' -5" 0
0 ,1 RAD C
BEfA SECTOR k,~ --------------~ I o::: --" -IL. i'---ALPHA SECTOR T T r--T T
ENTER OF PROPOSED ANTENNAS. ±-13' -3" 0
TOP OF EXISTING ROOF. ±38' -9" 0
---------------------------------------------------------------------------------------------------------------------
--------------------------'
------------------------
----------------------------------------------------.. ---------
-------EXISTING BUILDING
------------------------------------------------__ -_----------------------------
GROUND REF. O' -o• 0
PROPOSED NORTH-EAST BUILDING ELEVATION (ALPHA) NO SCALE 2
PLANS PREPARED FOR:---------
~
Sprint f,I>
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:----------
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALJFORNIA 92630
JOB #551-001
CONSULTANT:------------
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: ---------
DRAWING NOTICE:-----------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:-------------
DESCRIPTION DATE BY REV
90% CD's Cll A
REVISED 90% CD's CKE B
SITE NAME:-------------
PALOMAR
AIRPORT & 1-5
SITE CASCADE:------------.
SD03XC143
SITE ADDRESS:------------.
701 PALOMARAIRPORTROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:----------
BUILDING ELEVATIONS
SHEET NUMBER:-----------
A-5
-------------~
1900 MHz 4X45W 65 MHz RRH
MANUFACTURER:
MOIJEJ..:
WEIGHT:
Al.CATEL-LUC£NT
CllMA/LTE DUAL TECH 4X45W
59.5 LBS
RRH CABINET
FRONT
CLEARANCES MM COMMENTS (INCHES)
914 36' INSTALLATION ACCESS
REAR 50 {1.97) O" CLR W/ MOUNTING BRACKETS
• ~
IO N
RIGHT
LEFT
TOP
BOTTOM
10.7"
SIDE VIEW
300
300
300
355
11.82
11.82
11.82
14
= r-,.
0
~
AIR FLOW
AIR FLOW
AIR FLOW
CONDUIT ROUTING
TOP VIEW
REMOTE RADIO HEAD (RRH) 1900 MHz
PANEL ANTENNA SPECIFICATION
MN,iUFACTURER:
MODEL:
DIMENSIONS (HxWxD):
WEIGHT:
NOKIA
2.5G MM-MHF (0064R)
25.6" X 19.7 X 9.7"
103.7 LBS
9.7"
SIDE
MONmlR PORT N lYPE
RAE
LED X 3
• '° '° N
19.7"
FRONT
QSFP X 3
MDR26
DC-IN
BOTTOM
11.1 n
FRONT VIEW
800 MHz RRH
MANUFACTURER:
MODEL:
WEIGHT:
PHYSICAL DIMENSIONS (HXWXD):
WEIGHT:
OUTPUT POWER:
FREQUENCY RANGE:
CONSUMED POWER (TYP):
INSTANTANEOUS BANDWIDTH:
ANTENNA INTERFACE :
OPERATING TEMPERATURE RANGE:
SUPPORTS AISG 2.0
13"
0 • O@ @
TOP VIEW
4.9"
.11..-1
= IO
v
~
.....
'1C -d
SIDE VIEW
RRH MAKE AND MODEL
MANUFACTURER: NOKIA
MODEL: FZHN Flexi RRH 8TR
2600 8*2OW 473262A
NOTES
COMPLY WITH MANUFACTURERS
INSTRUCTIONS TO ENSURE THAT ALL RRH
RECENE ELECTRICAL POWER WITHIN 24
HOURS OF BEING REMOVED FROM THE
MANUFACTURER'S PACKAGING. DO NOT
OPEN RRH PACKAGES IN THE RAIN
ANT {TYP. OF (8))
BEAM
FORMING
1s.s·
FRONT VIEW
EAC
OPTx2
PLAN VIEW
NO SCALE 1 REMOTE RADIO HEAD (RRH) 2500 MHz
0
0
ALCATa-UJCENT
CDMA
53 LBS
19.7"X 13"X 10.8"
53 POUNDS
2X5DW (100W TOTAQ
862.275 -869MHZ TX / 817.275 -824 RX
425W
6.725 MHZ
7/16 DIN FEMALE
MANUFACTURER:
MODEL: CDMA/LTE DUAL TECH 2X50W
WEIGHT: 64 LBS
POWER SUPPLY: --18 WC
POWER CONSUMPTION: <400W lYPICAI.
-40C TO +50C {WliH SOLAR LOADING), +55C {WliHOUT SOlAR LOADING)
10.8·
/
] I
] I • r-,.
0,
~ ] I
] I
FRONT VIEW SIDE VIEW
PANEL ANTENNA SPECIFICATION
MANUFACTURER:
MODEL:
DIMENSIONS (HxWxD):
WEIGHT:
• ID . r-,.
• ID
21.0"
TOP
21.0·
CCI
WA65R-KE6D
71.2" X 21.0" X 7.8•
66.0 lBS
. I
r-,.
Lil~ 0 lil~!tiJ 0 0 0 0
RF CONNECTOR
{TYP.) BOTTOM
I 7.8· I
SIDE
PANEL ANTENNA NO SCALE 3 REMOTE RADIO HEAD (RRH) 800 MHz NO SCALE 4 PANEL ANTENNA
-------------------------------------------------··----·· --------
0
DC IN
GROUNDING
RET
NO SCALE 2
• N .
~
21.0·
11111111,1.1 I I I I I I I I '
FRONT
NO SCALE 5
PLANS PREPARED FOR:----------.
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:---------.
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB #551-001
CONSULTANT:-----------.
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: --------.
DRAWING NOTICE:----------.
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:------.---,---.---.
DESCRIPTION DATE BY REV
90% CD's Cll A
REVISED 90% CD's CKE B
SITE NAME:------------.
PALOMAR
AIRPORT & 1-5
SITE CASCADE:-----------.
SD03XC143
SITE ADDRESS:-----------.
701 PALOMAR AIRPORT ROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:---------
EQUIPl\ffiNT DETAILS
SHEET NUMBER:----------
D-1
-----·--·-----------------
ALCATEL-LUCENT
9712 LIGHTRADIO
OUTDOOR EQUIPMENT CABINET
WEIGHTS:
13U CABINET: 176 LBS
21 U CABINET: 231 LBS
PLINTH (BASIC): 55 LBS
PLINTH (BASIC)-------...
PLINTH (EXTENDED)
9712 LIGHTRADIO CABINET DETAIL
FIBER OPTIC & DC POWER JUNCTION BOX
MAKE:
MODEL:
WEIGHT:
DIMENSIONS (WxDxH):
DC DIST. /
FIBER MANG. BOX
PHOENIX CONTACT
9800960
60 LBS
36" X 36" X 12"
CLEARANCES MM
{INCHES)
914 36)
50 (1.97)
152 6
152 6
152 6
304 12)
COMMENTS
INSTALLATION ACCESS
O" CLR W/ MOUNTING BRACKETS
INSTALLATION ACCESS
INSTALLATION ACCESS
INSTALLATION ACCESS
CONDUIT ROUTING
JUNCTION BOX DETAIL
36"
LL!
FRONT VIEW
TOP VIEW
• ,,,
~
10.83"
• ~ ~
-
.
NO SCALE 1
C
SIDE VIEW
00000 I ·
BOTTOM VIEW
NO SCALE 3
... ...
... ..
.. ..
...
SIDE VIEW
FUTURE GROWTH CABINET
(N)RRH~/, .'
SIDE SUPPORT llRAKET WITH EARS-~
(Al.CAffi-LUCENT #849147053),
(2) PER RRH WHEN REQUIRED
(E) (OR NEW) PIPE MOUNT-~
MAIN SUPPORT BRACKEr
(ALCAffi-WCENT #849147038)
RRH POLE MOUNTING BRACKET DETAIL
BTS DOOR
CLEARANCE FRONT DOOR SWING
DOOR SWING
NO SCALE
MAST OR PIPE MOUNT BRACKEr
(N.CAffi-LUCENT #849073713),
(2) PER RRH
NO SCALE
-------------------~----~--------------------------------------------------------
2
4
PLANS PREPARED FOR:---------,
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:----------,
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CAUFORNIA 92630
JOB #551-001
CONSULTANT:-----------.
MD7, UC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: --------,,
DRAWING NOTICE:---------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPER1Y OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVISIONS:-------....,.-.,....--,
DESCRIPTION BY REV
90% CD's Cll A
REVISED 90,0 CD's CKE B
SITE NAME:-----------,
PALOMAR
AIRPORT & 1-5
SITE CASCADE:----------.
SD03XC143
SITE ADDRESS:----------,
701 PALOMAR AIRPORT ROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:--------
EQUIPMENT DETAILS
SHEET NUMBER:----------,
D-2
.
D 3Ȣ
£DUL£
PROPOSE.
O.D. SCH
40 PIPE
TENNA
00
0 --ti
BRACKET
SEMBLY P/N:
-
u<J ,,.
H
' no -
±4.9"
,MIMD ANTENNA MOUNTING BRACKET (FPKA
ASSEMBLY P/N: 084020A)
±24.5"
±19.6" I -------_--i ___ j
' ~ . ... -PROPOSED NOKIA MASSIVE MIMD
-
D
,;,,,,;,,!!"'s,--"fifLI [Q~=q ---ANTENNA
CJ ~ I .:==
(J
0
DI
±14.9"
±14.9"
i ; ID] .!0 c-cl .. 1G l.---~ 1
' '
•.IOi\.-< --------I -------·-I '==' -------· I
ID]
.,&...~\:1:': □ = -
~.ii .. :_. ~
I ±9.7'
~
'
±24'-6""
±9.7"
I
'
±9.0" ±5.9"
..--
' j 80 0
±8.5"
-
"' u-i
N -H
PROPOSED NOKIA MASSIVE MIMO
ANTENNA
MIMO AN
MOUNTING
(FPKA AS
084020A) ~ .
;-:
I/; 01 .
-
.......
I . ±19.6"
NOKIA MIMO MOUNTING DETAILS
RRH MOUNTING BRACKET KIT SPECIFICATION
MANUFACTURER:
PARr #:
DIMENSIONS {LxWxD):
WEIGHT:
MANUFACTURER:
PARr #:
DIMENSIONS (LxWxD):
WEIGHT:
,h
I ...,
--.. -
!;;
"' . , -..,
' i
'
'
i
•
CUE DEE
6140
21.6" X 3.r X 3.7"
11.0 LBS
CUE DEE
6141
15.0" X 3.5" X 3.3"
6.2 LBS
fV'l -
,u " ,_.,. .
r -
•
, ,---. -__ , -------
---------
RRH MOUNTING DETAIL
(E.) (OR NEW) PIPE MOUNT--,
RRH POLE MOUNTING BRACKET KIT
(CUE DEE P/N: 6140/6141) -,
NO SCALE 1
/ I
.0
---/
--,-,
J
NO SCALE 3
DETAIL "A"
D
□□
274
CJ
CJ
" " I! !I
FPKA BRACKEr 823336 1 pcs. --,
Ii " " II " "
BOLT RESTAINER 822861 2 pcs
HEX SCREW M8X20 DIN 933/IS04D17
M-706190924 -6 pcs
TIGHTENING: 4 ±1 Nm-~
FPKA BRACKET
SIRAINER 823337
1 pcs
BOLT M10x120 105mm lHR£All
821832 OSP 4762 {DIN912) 2
pcs PRE TIGHTENING FOR
PACKEilNG: SCREW FIVE (5)
FlRST THREAD
FRONT VIEW " " Ii
" "
Ii " II \ ISOMETRIC VIEW
EXISTING RF FRIENDLY
SCREEN (1YP .)
.
J J ~
"-0 .,_
2
0 >-
C, z ~ 0 "' 0 I 'i: 0 w :c
J ~ 0 >-
~
EXISTIN G/NEW STEEL
TUBE FRAME (1'/P.)
•. : .. .
1
• .
' •
>: .
..
. .
I
. i
·• I
' .
.. ' . . • . ..
I>:·,
I
• i
'
.·· ' '
'
' ' ..
' •
.
' . .
• •
.'
y
-':-',
' ' • '
:~ 1
I':,
<': .
'
I
"
I ,
' I
\
DETAIL "A"
/\
I \
f-, ' ' ' ' ' ' ' ' ' ' ' ' ' l ,
' ' l / ' , I / y
'------f:ASTENING FEATURES THIS SIDE
MIMO NOKIA FPKA MOUNTING BRACKET
/
. .. .
G b--,
. ---
c~~ i
'
• •
• ~
-•
.'
y
f
• .
EXISTING/NEW STEB..
TUBE FRAME (1'/P.)
LVANIZED EXISTING 3"1'l GA
S10. PIPE (TYP. )
NA MOUNTING
DWARE
DOWNTIL T ANTEN
BRACKET & HAR
(VARIES PER AN TENNA MODEL)
(NJ PANEL ANTENNA
EXISTING 3"1'l GAL
S10. PIPE (TYP.
VANIZED
)
UNTING KIT (MOUNTS VARY (N) AN1ENNA MO
DEPENDING ON A
AN1ENNA MOUNll
D-3, DETAIL 2)
NTENNA MODEL) (FOR MIMD
NG BRACKET, SEE SHEET
NEW JUt.lPER CABLES (TYP.)
EXISTING/NEW 1-5/
HORIZONTAL PIPE (1YP
s·,
.)
-
~
-
(=-
' ? ) FRONT VIEW
--
~ ::::::::: --------------·------
I 30"
MIN. DEPTH
SIDE VIEW
ANTENNA PIPE MOUNT
NO SCALE 2
-
--
• •
• •
------
~
REAR VIEW
NO SCALE 4
-----· --------------------------------· ·-~ .. -------·~·---·-------------
PLANS PREPARED FOR:---------
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:----------.
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB #551-001
CONSULTANT:------------
MD7, LLC
10590 WEST OCEAN AIR DR i/300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: ---------.
DRAWING NOTICE:-----------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT .
REVISIONS:------.,...--.,.....--,--.
DESCRIPTION BY REV
90% CD's Cll A
REVISED 90% CD's CKE B
SITE NAME:-------------.
PALOMAR
AIRPORT & 1-5
SITE CASCADE:------------.
SD03XC143
SITE ADDRESS:------------.
701 PALOMARAIRPORTROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:----------.
EQUIPMENT DETAILS
SHEET NUMBER:-----------
D-3
SECTOR
1 -ALPHA
1
1
1
1
1
1
1
2 -BETA
2
2
2
2
2
2
2
3 -GAMMA
3
3
3
3
3
3
3
FIGURE 19.1 CABLE COLOR CODE FIGURE 19.2 COLOR CODE
lYPICAL COAX CABLE COLOR CODI NG SCHEME
CABLE FIRST RING SECOND RING THIRD RING 2.5
1 GRN NO TAPE NO TAPE FREQUENCY INDICATOR
2 BLU NO TAPE NO TAPE 2500 -1 YEL WHT
3 BRN NO TAPE NO TAPE 2500 -2 YEL WHT
4 WHT NO TAPE NO TAPE 2500 -3 YEL WHT
5 RED NO TAPE NO TAPE 2500 -4 YEL WHT
6 SLT NO TAPE NO TAPE
7 PPL NO TAPE NO TAPE 2500 -5 YEL WHT
8 ORG NO TAPE NO TAPE 2500 -6 YEL WHT
1 GRN GRN NO TAPE 2500 -7 YEL WHT
2 BLU BLU NO TAPE 2500 -8 YEL WHT
3 BRN BRN NO TAPE
4 WHT WHT NO TAPE
5 RED RED NO TAPE NV
6 SLT SLT NO TAPE FREQUENCY INDICATOR ID
7 PPL PPL NO TAPE 800-1 YEL GRN
8 ORG ORG NO TAPE
1 GRN GRN GRN 1900-1 YEL RED
2 BLU BLU BLU 1900-2 YEL BRN
3 BRN BRN BRN 1900-3 YEL BLU
4 WHT WHT WHT 1900-4 YEL SLT
5 RED RED RED 800-1 YEL ORG
6 SLT SLT SLT RESERVED YEL WHT
7 PPL PPL PPL RESERVED YEL PPL
8 ORG ORG ORG
NOTES:
1. ALL CABLES SHALL BE MARKED AT THE TOP AND BOTTOM WITH 2• COLORED TAPE, STENCIL TAG COLORED TAPE, OR COLORED
HEAT SHRINK TUBING.
2. COLORED TAPE MAY BE OBTAINED FROM GRAYBAR ELECTRONIC. UV STABILIZED TAPE OR HEAT SHRINK ARE PREFERRED.
3. THE FIRST RING SHALL BE CLOSEST TO THE END OF THE CABLE, AND THERE SHALL BE A 1 • SPACE BETWEEN EACH RING.
4. THE CABLE COLOR CODE SHALL BE APPLIED IN ACCORDANCE TO TABLE 19-1.
A) TABLE 19-1 ONLY SHOWS 3 SECTORS, BUT ADDmONAL SECTORS ARE EASILY SUPPORTED BY ADDING THE APPROPRIATE
NUMBER OF COLORED RINGS TO THE CABLE COLOR CODE.
5. AFTER THE CABLE COLOR CODE IS APPLIED, THE FREQUENCY COLOR CODE , TABLE 19-2, MUST BE APPLIED FOR THE SPECIFIC
FREQUENCY BAND IN USE ON A GIVEN LINE.
A) 2" GAP SHALL SEPARATE THE CABLE COLOR CODE FROM THE FREQUENCY COLOR CODE.
B.) THE 2" COLOR RINGS FOR THE FREQUENCY CODE SHALL BE PLACED NEXT TO EACH OTHER WITH NO SPACES.
6. WRAP 2" COLORED TAPE A MINIMUM OF (3) TIMES AROUND THE COAX, AND KEEP THE TAPE IN THE SAME AREA AS MUCH AS
POSSIBLE. THIS WILL ALLOW REMOVAL OF TAPE THAT FADES OR DISCOLORS DUE TO WEATHER.
7. EXAMPLES OF THE CABLE AND FREQUENCY COLOR CODES ARE SHOWN IN FIGURE 19-1 AND FIGURE 19-2
ANTENNA AND CABLE COLOR CODE STANDARDS
ID
GRN
RED
BRN
BLU
SLT
ORG
WHT
PPL
SCALE
N.T.S. 4
HYBRID -2.5 Band NV CABLES
HYBRID COLOR 2500 Radio 1 COLOR BAND INDICATOR PORT
1 GRN YEL WHT GRN 800-1 YEL GRN NV-1
2 BLU YEL WHT BLU 1900-1 YEL RED NV-2
3 BRN YEL WHT BRN 1900-2 YEL BRN NV-3
4 WHT YEL WHT WHT 1900-3 YEL BLU NV-4
5 RED YEL WHT RED 1900-4 YEL SLT NV-5
6 SLT YEL WHT SLT 800-2 YEL ORG NV-6
7 PPL YEL WHT PPL SPARE YEL WHT NV-7
8 ORG YEL WHT ORG 2500 YEL PPL NV-8
ANTENNA AND CABLE COLOR CODE STANDARDS
91.217 [5.50]v
v12 CHANNEL
FIBER DIST. B'i"I''----,,.
3
91.117 [2.97]v
INSULATED
EPOXY GLASS-__,,
ROD
~-OUTER
JACKET
~-INNER
JACKET
NOTE: CABLE CROSS-SECTION NOT DRAWN TO
SCALE
ASSEMBLY
LENGTH, FT
25
50
75
100
125
150
175
200
HYBRIFLEX RRH FIBER ONLY CABLING SOLUTION, OX18, RISER, 5/8", MULTI-MODE FIBER
MECHANICAL PROPERTIES
WEIGHT, APPROXIMATE 0.36 I 0.242)
MINIMUM BENDING RADIUS, SINGLE BENDING 90 (4
MINIMUM BENDING RADIUS, REPEATED BENDING 254 (10)
FIBER OPTIC PROPERTIES MULTI-MODE BEND TOLERANT FIBER-12
VERSION CHANNEL CABLE
QUANTITY, FIBER COUNT 18 PAIRS 9 MAIN, 9 SPARES)
MINIMUM BENDING RADIUS {INSTALLATION) 114.3 (4.5
ENVIRONMENT INSTALLATION -20 TO +65 (-4 TO +149) TEMPERATURE
OPERATION TEMPERATURE -40 TO +65 -40 TO +149
STORAGE TEMPERATURE -40 TO +70 -40 TO +158
HYBRIFLEX FIBER CABLE -
SPECIFICATIONS
MODEL NUMBER DESCRIPTION
HB058-M12-025F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HB058-M12-050F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HB058-M12-075F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HB058-M12-100F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HB058-M12-125F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HB058-M12-150F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HB058-M12-175F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HB058-M12-200F 18PR MULTI-MODE FIBER. TOP: 3 MPO CONNECTOR: BOTTOM: 18 LC CONNECTORS
HYBRIFLEX 5/8"0, MULTI-MODE FIBER SCALE
N.T.S. 1
PE/UV
JACKET
ALUMINUM OC--
OPTICAL CABLE
(QUAD) WITH AN
INTERNAL JACKU-----'
(PE/UV)
1-1/4", 4-PAIR 8AWG
X 5-PAIR
MULTI-MODE FIBER
UL
POWER CABLE
(PAIR) WITH AN
INTERNAL JACKET
(PE/UV)
.__ __ .,..,PTICAL CABLE
(PAIR) WITH AN
INTERNAL JACKET
HB114-1-08U4-M5J (PE/UV)
HYBRIFLEX RRH HYBRID FEEDER CABLING SOLUTION
STR!JCTUBE
OUTER CONDUCTOR CORRUGATED ALUMINUM ARMOR: [MM (IN)]
JACKET: POLYETHYLENE, PE MM {INJ
UV-PROTECTION: INDMDUAL AND EXTERNAL JACKET
MECHANICAL PBOPERTIES
WEIGHT, APPROXIMATE KG/M LB/FT)l
MINIMUM BENDING RADIUS, SINGLE BENDING: MM IN
MINIMUM BENDING RADIUS, REPEATED BENDING: MM IN
RECOMMENDED/MAXIMUM CLAMP SPACING M (FTJ
ELECTRICAL PROPERTIES
DC-RESISTANCE OUTER CONDUCTOR ARMOR O'KM a:1000F1
DC-RESISTANCE POWER CABLE, 8.4MM• C8AWGJ a 'KM a, 1000tl
FlBER OPTIC PBOPERTIES
VERSION
QUANTITY, FIBER COUNT
CORE/CLAD um
PRIMARY COATING (ACRYLATE) um
BUFFER DIAMETER, NOMINAL um
SECONDARY PROTECTION, JACKET, NOMINAL MM INl
STANDARDS (MEETS OR EXCEEDS}
~ PQWER CABLE PBOPEBI!ES
SITE rMM2 (AWG)l
QUANTITY, WIRE COUNT
TYPE
STRANDS
PRIMARY JACKET DIAMETER, NOMINAL MM (IN I
STANDARDS (MEETS OR EXCEEDS) *REFER TO SPEC SHEET"'
36.0 (1.42)
39.0 (1.54)
YES
1.61 1.08)
200 8)
500 2D
1.0/1.2 3.25/4.0
.61 (1.08)
,.1 (.64
MULTI-MODE
5 PAIRS
50/125
245
900
2.0 (0.08)
UL94-VO, UL1666
RoHS COMPLIANT
8.4 (8)
8 (4 PAIRS)
UV PROTECTED
19
6.1 (0.24)
ICEA S-95-658
HYBRIFLEX 1-1 4"0, MULTI-MODE FIBER SCALE
N.T.S. 2
COLOR
GRN
BLU
BRN
WHT
RED
SLT
PPL
ORG
FIGURE 1: ANTENNA ORIENTATION
SECTOR 3
GAMMA
81 B2
SECTOR2
BETA
83 B4
SECTOR 1
ALPHA
A1
EXAMPLE -SECTOR 2,
CABLE 2, 800Mhz RADIO #1
EXAMPLE -SECTOR 3,
CABLE 1, 1900Mhz RADIO #1
EXAMPLE -SECTOR 1, CABLE 4, 800Mhz
RADIO #1 AND 1900Mhz RADIO #1
SCALE
N.T.S. 3
--------------------------------
PLANS PREPARED FOR:--------
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:---------.
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CAUFORNIA 92630
JOB #551-001
CONSULTANT:-----------.
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: --------.
DRAWING NOTICE:---------...
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT.
REVJSIONS: -----...... --...-...,...-
DESCRIPTION DATE BY REV
90% CD's
REVISED 90% CD's CKE B
SITE NAME:-------------.
PALOMAR
AIRPORT & 1-5
SITE CASCADE:----------
SD03XC143
SITE ADDRESS:----------
701 PALOMARAIRPORTROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:---------.
RF DATA SHEET
SHEET NUMBER:---------....,
D-4
SYMBOL LEGEND
■ EXOTHERMIC CONNECTION
.A MECHANICAL CONNECTION
NEW AMOB
FUTURE (E)
GROWTH BATTERY
CABINET RACK
...
! • • I ! i ' t L
NEW TOP HAT
BBU 2.5GHz
EXISTING
MMBTS
RECTIFIER
• I • • ! (E) GROUND • ! WIRE •
LNEW AWG #2
INSTALL MOUNTING
PIPE (lYP) -------.
INSTALL
ANTENNAS (lYP) ---i
INSTALL RRU
(lYP) ---......_
' ' ' JUMPER CABLES , 1' , I •
' ' '
AWG #6 (lYP.)
(lYP) ------<D-H-~I +-: --cI)-+t--f'7,-<D i
U, ' :1 u· • :! u' • I : I ' I , I i : i :
FIBER & DC : I
i L______________ --------~ ~---------------------1 !
CABLES (lYP) -----<:D--t--, ,....I ---<D-+-::-_-__ -__ -::__--<: __ D_________________ --,)
i : I I
BREAK OUT i L _______ --------------------------
CYLINDERS (lYP) ----.:::.---t---'----_-~:---=-------t------:=---=......._-------------------1
rNEW AWG #2
PROPOSED
HYBRID CABLE.a--cr:::>----------<IT>-----c:J:)
(lYP)
HYBRID
DISTRIBUTION
BOX
<DCD::P-----(E) GROUND
WIRE r'~li
-~(E) SHELTER GROUND
BAR AT COAX PORT
(E) UPPER
GROUND BAR
(lYP)
GROUNDING RISER DIAGRAM {FOR REFERENCE ONLY) NO SCALE
(E) EQUIPMENT
MASTER GROUND BAA
. ~,£7':
/
TO (E) GROUNDING SYSTEM
OR COID WAlER PIPE
,,-
i i
i i
.
\
\
(E) GROUNDING TO MGB
AT LEASE NI.EA
' I .. .-•-•-•-•-·---·---·----•---•-•---•-•---~~ ,i.
I ! . ! ..
'•, ( {E) GR!XNl WIRE
\
----! I.~ -------·----·--•-·-~ . -•---·------------·---{E) MASTER GROUND BAA . \ .
L ! I
3
r•--·-•-•-•--•--...J: L•-•--•-•--7 j (E) SECTOR GROUND BAA
! ------1 .,.,"" . ,,
A , .
/ !
/ ! I I
PROPOSED SPRINT FIBER JUNCTION
BOX {1YP. OF (1) TOTAL)
PROPOSED SPRINT
FUTURE GROWTH CABINET
EQUIPMENT GROUNDING PLAN
!
!
!
!
!
\_~~~,-
EQUIPMENT CABINET (TYP. OF (1) TOTAL)
NO SCALE
--------------------~----------~--------
5
/
I
I
!
!
✓
/
/
,,.,. _,,.
·-· ✓----. . .
i ·, '-.\. '· . ·, "-'· '·
I \ "-'• '-. /. i ·, \. '-'-, . . "' ~ I• \ \ ·, '· '-.. . . ....... .......
I• \ \ \. ·--.. '· . .. .............. .. i \ \ \. , ...... ____ __
/• ·1 ' -...--~--.. ·, ....... _.J
/
AWG f6 (TYP.)
TYPICAL ANTENNA & {E)
GROUNDING PLAN NO SCALE 4
EXISTING GROUNDING BAR
ON WALL, FLOOR, OR ON
ANTENNA TOWER --~
#4 OR #6 AWG SOLID CU
CONDUCTOR WITH GREEN, 600V,
THWN-2 INSULATION
TWO HOLE SPADE, TO BE USED
TO CONNECT TO GROUND BAR-~
NOTES
1. APPLY NO-OX TO LUG AND BAR CONTACT SURFACE. DO
NOT COAT INUNE LUG.
2. If STOLEN GROUND BARS ARE ENCOUNTERED, CONTACT
SPRINT CM FOR REPLACEMENT THREADED ROD KIT.
INSTALLATION OF GROUNDING
CONDUCTOR TO GROUNDING BAR NO SCALE
BUTT CONDUCTOR INSULATION UP
AGAINST THE CONNECTOR BARREL
INSPECTION WINDOW
REQUIRED FOR ALL INTERIOR
TWO-HOLE CONNECTORS ---,
EXTERNAL TOOTHED
3/8"!15x1 1 /2"
S/S NUT
S/S LOCK
WASHER
COLD SHRINK OR
APPROVED EQUAL
s/s FLAT
WASHER __/ /
S/S BOLT__/
(1 OF 2)
TINNED COPPER
GROUNDING BAR-_,
GROUND BAR
COLD SHRINK OR
APPROVED EQUAL
"DO NOT DISCONNECT" TAG ON
ALL GROUNDING BAR
INTERCONNECTS AND EQUALIZERS
TWO HOLE LUG
LABEL
1 4" MIN
DO NOT
DISCONNECT
NO SCALE
1
2
PLANS PREPARED FOR:----------,
Sprint
3730 5TH AVE.
SAN DIEGO, CA 92103
PLANS PREPARED BY:---------.
INFINIGY8
FROM ZERO TO INFINIGY
the solutions are endless
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA92630
JOB #551-001
CONSULTANT:-------------,
MD7, LLC
10590 WEST OCEAN AIR DR #300
SAN DIEGO, CA 92130
858.799.7850
ENGINEERING LICENSE: ---------
DRAWING NOTICE:----------
THESE DOCUMENTS ARE CONFIDENTIAL AND
ARE THE SOLE PROPERTY OF SPRINT AND MAY
NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS
WRITTEN CONSENT OF SPRINT .
REVISIONS: -----'"""I"---,---,,---,
DESCRIPTION DATE BY REV
90% CD's
REVISED 90% CD's CKE B
SITE NAME:------------
PALOMAR
AIRPORT & 1-5
SITE CASCADE:-----------
SD03XC143
SITE ADDRESS:-----------
701 PALOMARAIRPORTROAD
CARLSBAD, CA 92009
SHEET DESCRIPTION:---------.
GROUND PLAN & DETAIL
SHEET NUMBER:----------
E-1