Loading...
HomeMy WebLinkAboutCD 11-06; ROBERTSON RANCH PA 16; Consistency Determination~1-21 -y2s 1, \ 35 c.. ,--7 -'""r--7 -"" I I <c ~--r--7 -N I~ .... I I ~ ---:_I I I I I I ' . \ • ' ~~ - o· 10· 40• ----20· 80' SCALE: 1" = 40' • ... .. r 1...... • 1 1 !,.J'I • 50,L----I ,1 ~\ , 1~ 1.---_jc:::i. so· ' :.: \ J ~ 50' : ' •,. I --1\ \.----' ' .,., -\. . PLAN-LOTS 160, 162 ANO 186-189 SCALE: I" = 40' PLAN-LOTS 90, 92, 94-95, ANO 99 SCALE: 1• = 40' o' 10' 40' ----20' 80' SCALE: 1" = 40' ©2011 O'Day Consultants, Inc. SHEET 1 OF 1 SHEETS CD 11-06 CONSISTENCY DETERMINATION EXHIBIT FOR ROBERTSON RANCH EAST VILLAGE PLANNING AREA 16 LOTS 90, 92, 94-95, 99, AND LOTS 160, 162, 186-189 P. U.O. 06-12(A) PLANNING AREA 16 UNIT SUMMARY COMPARABLE ANALYSIS PlAN ORIGINAL CD 11-02 PROPOSED DIFFERENCE JI OF UNITS JI OF UNITS # OF UNITS FROM CD 11-02 PLAN I (ONE STORY) /J '153%. /J '/5J%, IJ '153%. NO CHANGE PLAN IX (BONUS ONE STORY! 10 11.8%. IJ 15J%, 11 20.0%. INCREASED BY 4 -PLAN 2 lJIO STORY. JO J53%. 21 J/.8%.' 22 259%.1 DECREASED BY 5 PLAN J lJIO STORY. J2 Jl.6%. 32 (31.6%} 33 (38.8%,l INCREASED BY I PLANNING AREA 16 LOT SUMMARY COMPARABLE ANALYSIS ORIGINAL PROPOSED LOT# LOT AREA PAD AREA PlAN 1 PLAN 90 6000 SF 5000 SF IXAR IXCR 92 6000 SF 5000 SF 2AR /XAR 94 6000 SF 4996 SF IBR /AR 95 5998 SF 5026 SF 2CR IXBR 99 7305 SF 6286 SF IA IC 160 5512 SF 5512 SF 2CR JAR 162 5000 SF 5000 SF JAR JCR 186 5945 SF 5001 SF 2A (2A'! 18 187 5907 SF 5000 SF 18 IXA 188 5915 SF 5000 SF JA 38 189 6163 SF 5000 SF 28 IXC NOTES FOR LOT SUMMARY TABLE: I. "R" /NO/CATES REVERSED FlOORPLAN 2. • INDICATES REl4SED FRONT YARD TO ADD A COURTYARD. 3. BUILDING COlt'RAGE {NO CHANGE) PLAN I = 2632 SF PLAN IX= 2634 SF PLAN 2 2A/8 = 2230 SF 2C = 2250 SF PLAN 3 JA = 2196 SF 38 = 2199 SF JC = 2216 SF ORIGINAL PAD COVERAGE 52.1% 44.6% 52.7% 44.8% 41.9% 40.8% 419% 44.5% 52.6% 43.9% 44.6% 5 A !£RAGE FRONT YARD SETBACK FOR PA 16 (85 UNITS) = 14.5' 6. FRONT YARD SETBACK ON PLAN 2A • IS TO THE COLUMN AT THE WALL. 1. (} !NO/CA TES APPROlt'D BY CD 11-02, MARCH 4, 2011. PROPOSED PAD COVERAGE 52.7% 52.7% 52.7% 52.4% 41.9% 39.8% 44.3% 52.6% 52.7% 14.0% 52.7% 8. 64 OF 85 LOTS (75%} IN PA 16 MEET THE 8.5' MINIMUM A !£RAGE S!DEYARD SETBACK. ORIGINAL FRONT YARD SETBACK 10.0· 153' 10.0' 117' 10.0' 111· 18. 4' 153' (10.0? 10.0' 18. 4' 117' PROPOSED ORIGINAL PROPOSED AVERAGE AVERAGE FRONT YARD SIDE YARD SIDE YARD SETBACK 6 SETBACK SETBACK 10.9' 6. 4' 6.4' 10.8' 9.4' 6.4' 12. /' 6. 4' 6.4' II./' 8.2' 6.4' 10.0' 20.2 20.2 14.9' 118' 116' 14.9' 8.5' 8.8' Ill' 9.4' (9.4'! 6. 4' 10.9' 6.4' 6. 4' 14.9' 8.5' 8. 7' 10.6' 8. 9' 6. 4' CONSJSTcNCY DF.TFRMINATIOI\ F.XHJBIT Q~ FOR PROJECT NO. Pl!D.06-l2(AJ _ -)1q(I D,tc Slteja:.1/ Oon N<.'u, Plunnmg 0irc-dor REC0\1Ml"'lDED BY· L~ DATE•.;?Lll,./~-,1/ ROBERTSON RANCH PA-16 BENCHMARK: DESCRIPTION: STANDARD M-10 STREET CENTERLINE WELL MONUMENT LOCATION: CENTERLINE OF EL CAMINO REAL AT ENGINEER'S STATION 454+92 PER R.S 1800-1 RECORD FROM: COUNTY BENCH LElt'LS (NO. COUNTY !£RT. CONTROi. DA TA) ELEVATION: 68.479 OA!VM: /J.S.C. &-G.S. REl4SED MAY 5, 2011 APRIL 20, 2011 c~/~~, s 2710 Loker Ave. West CiYil Engineering Suite 100 Planning Corlsbad, California 92010 Processing 760-931-7700 Sur,,,eying fo1C: 760-931-8680 www.odayconsultonts.com G: \011014\0114MPCD201.dwg Moy 11, 2011 12: 52pm SHEET 1 OF 1 SHEETS DESIGNED BY: N.F. DATE: APRIL 2011 DRAWN BY: N.F. SCALE: 1· = 40' PROJECT MGR.· G.O. JOB NO.: 081245 ENGINEER OF WORK ~~'/J,.,, GEORGE O Y ) DATE:,><,,><' IZ.,lGI, ' RCE: r,12014 V Xrefs: 01148GRD; 0114BSTR; 01148UTI..; 01148MAP; 0114TP-G; 0114MPFP; 0114gslr; 0114ggrd; 0114gmap; 0114MPCD2; 0114gutl 'i - --