Loading...
HomeMy WebLinkAboutCD 16-14; VERIZON MCCLELLAN; Consistency DeterminationPROJECT TEAM SITE ACQUISITION RELIANT LAND SERVICES, INC. 1745 W. ORANGEWDOD AVE., SUITE 103 ORANGE, CA 92868 CONTACT: STELLA SHIH TELEPHONE: (714) 396-0459 ARCHITECT: RELIANT LAND SERVICES, INC. 1745 W. ORANGEWOOD AVE., SUITE 103 ORANGE, CA 92868 CONTACT: JOY SALAS TELEPHONE: (714) 685-0123 PLANNING RELIANT LAND SERVICES, INC. 1745 W. ORANGEWOOD AVE., SUITE 103 ORANGE, CA 92868 CONTACT: STELLA SHIH TELEPHONE: (714) 396-0459 PROFESSIONAL ENGINEER: RELIANT LAND SERVICES, INC. 1745 W. ORANGEWOOD AVE., SUITE 103 ORANGE, CA 92868 CONTACT: CHRIS LEE TELEPHONE: (949) 468-9702 VERIZON WIRELESS SIGNATURE BLOCK DISCIPLINE: SIGNATURE: DATE: RE VENDOR: A&EVENDOR: A&E COORDINATOR: UTILITY VENDOR: RF: RE: CE: EE: TRANSPORT: ---------------··---·--- McCLELLAN MTX 54 I BSC 22 2710 LOKER AVENUE WEST CARLSBAD, CALIFORNIA 92010 PROJECT DESCRIPTION -PCS THIS PROJECT IS A MODIFICATION TO AN EXISTING VERIZON WIRELESS UNMANNED TELECOMMUNICATION WIRELESS FACILITY. IT WILL CONSIST OF THE FOLLOWING: • REMOVE AND REPLACE (6) EXISTING VERIZON WIRELESS ANTENNA WITH (6) NEW VERIZON WIRELESS ANTENNAS. • ADD (3) NEW RRUS WITH A-2 MODULES • ADD (3) A-2 MODULES TO (E) RRUS • REMOVE AND REPLACE 5'-0" FRP SCREEN BOXES AT GAMMA AND BETA SECTORS WITH PROPOSED 7'-0" FRP SCREEN BOXES TO ACCOMMODATE PROPOSED ANTENNAS • INSTALL HYBRIFLEX CABLE WITHIN EXISTING ROOF MOUNTED CABLE TRAY VERIZON WIRELESS RFDS DOCUMENT 12-24-2014 (PCS-LTE) VICINITY MAP DRIVING DIRECTIONS FROM: VERIZON OFFICE TO: 2710 LOKER AVENUE WEST CARLSBAD, CALIFORNIA 92010 1. HEAD SOUTHEAST TOWARD SAND CANYON SOUTH PATH 2. TURN RIGHT ONTO SAN CANYON AVE. 3. TAKE RAMP ONTO 405 S 4. KEEP RIGHT ONTO 1-5 (SAND DIEGO FWY) 5. TAKE EXIT 47 TOWARD PALOMAR AIRPORT ROAD 6. MAKE A U-TURN AT EL FUERTE ST. ONTO PALOMAR AIRPORT RD 7. TURN RIGHT ONTO LOKERAVEW 8. DESTINATION WILL BE ON THE LEFT PROJECT SUMMARY APPLICANT/LESSEE 15505 SAND CANYON AVENUE, D1 IRVINE, CA 92618 OFFICE: (949) 286-7000 APPLICANT'S REPRESENTATIVE RELIANT LAND SERVICES, INC. 1745 W. ORANGEWOOD AVE., SUITE 103 ORANGE, CA 92868 CONTACT: STELLA SHIH TELEPHONE: (714) 396-0459 PROPERTY OWNER: OWNER: FRANZ ATRIUM, L.P. ADDRESS: 6183 PASEO DEL NORTE, SUITE 280 CARLSBAD, CALIFORNIA 92009 CONTACT: LUPE ORTEGA TELEPHONE: 760-931-1134 PROPERTY INFORMATION: SITE NAME: McCLELLAN SITE ADDRESS: 2710 LOKER AVENUE WEST CARLSBAD, CA 92010 JURISDICTION: CITY OF CARLSBAD CONSTRUCTION INFORMATION ASSESSOR'S PARCEL NUMBER APN: 209-081-31 AREA OF CONSTRUCTION: OCCUPANCY: 200 SQ. FT. (NO CHANGE) B TYPE OF CONSTRUCTION: N/A CURRENT ZONING: PM ADA COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. MACHINERY SPACES ARE EXEMPT FROM ACCESSIBILITY REQUIREMENTS PER THE CBC SECTION 118-203.5. GENERAL CONTRACTOR NOTES DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. CODE COMPLIANCE • 2013 CALIFORNIA ENERGY CODE • • 2013 CALIFORNIA BUILDING CODE • • 2013 CALIFORNIA ELECTRICAL CODE • • 2013 CALIFORNIA FIRE CODE • 2013 CALIFORNIA GREEN BUILDING CODE 2013 CALIFORNIA MECHANICAL CODE 2013 CALIFORNIA PLUMBING CODE SHELTER IS STATE OF CALIFORNIA APPROVED AND INSPECTED, NOT FOR LOCAL INSPECTION. --·-·------------------------------------------ SHEET T-1 T-2 A-1 A-2 A-3 A-4 A-5 A-6 A-7 G-1 G-2 S-1 ISSUE STATUS REV. DATE DESCRIPTION BY 0 j 05/20/16 90% CONSTRUCTION LR 07/05/16 100% CONSTRUCTION DJL '-_ __.3TENCY DETERMlNATIONl!)fDBl'f F0" uRIGINAL PROJECT NO. ~:i-.J0 ... -~13~. --...... U--f------1----------l----l R~1'feNl)i;l>~; 1',S :0 .J_. DATE: / l_/3::, /1,. DESCRIPTION REV TITLE SHEET 1 GENERAL NOTES, LEGEND & ABBREVIATIONS 1 SITE PLAN 1 ROOF PLAN 1 EXISTING AND PROPOSED ANTENNA PLANS 1 EXISTING AND PROPOSED ELEVATION 1 EXISTING AND PROPOSED ELEVATION 1 EXISTING AND PROPOSED ELEVATION 1 DETAILS 1 ANTENNA GROUNDING PLA~J 1 .• GROUNDING DETAILS 1 FRP ANTENNA SCREEN & DETAILS 1 CONSTRUCTION DRAWINGS Know what's belo1vv. TO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN CALIFORNIA (SOUTH), CALL DIG ALERT TOLL FREE: 1-800-227-2600 OR www.digalert.org Call before you dig. CALIFORNIA STATUTE REQUIRES MIN OF 2 WORKING DAYS NOTICE BEFORE YOU EXCAVATE nl~' " ~ 70,, I,) r, Li IJ _i:;/.,• --' -1 . ,;.,._, ,,,,--..,, .. ,.:.-_..,," ·---~.\) Ill S RELIANT LAND SERVICES . - 1745 W ORANGEWOOD AVE. STE 103 ORANGE, CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX (714) 453-9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED z <( _J _J w _J (.) {.) ~ ~ 0 UJ ::> z UJ ~ z 0 >-z <( u 0 z <( Cf) LO c:, LO LO ~ 0 I-..... en o w~ s <( wz :::> 0::: zo w u. > ....I <( <( 0::: 0 ~ 0-o <C ....J ca o en ..... _J I'--0::: N <( 0 SHEET TITLE: TITLE SHEET T-1 co ~ co N a, <( u UJ z ~ A.B. ABV. ACCA ADD'L A.F.F. A.F.G. ALUM. ALT. ANT. APP RX. ARCH. AWG. BLDG. BLK. BLKG. BM. B.N. BTCW. B.O.F. B/U CAB. CANT. C.I.P. CLG. CLR. COL. CONC. CONN. CONST. CONT. d DBL. DEPT. D.F. DIA. DIAG. DIM. DWG. DWL. EA. EL. ELEC. ELEV. EMT. E.N. ENG. EQ. EXP. EXST.(E) EXT. FAB. F.F. F.G. FIN. FLR. FDN. F.O.C. F.O.M. F.O.S. F.O.W. F.S. FT.(') FTG. G. GA. GI. G.F.I. GLB.(GLU-LAM) GPS ANCHOR BOLT ABOVE ANTENNA CABLE COVER ASSEMBLY ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ALUMINUM ALTERNATE ANTENNA APPROXIMATE(L Y) ARCHITECT(URAL) AMERICAN WIRE GAUGE BUILDING BLOCK BLOCKING BEAM BOUNDARY NAILING BARE TINNED COPPER WIRE BOTTOM OF FOOTING BACK-UP CABINET CABINET CANTILEVER(ED) CAST IN PLACE CEILING CLEAR COLUMN CONCRETE CONNECTION(OR) CONSTRUCTION CONTINUOUS PENNY (NAILS) DOUBLE DEPARTMENT DOUGLAS FIR DIAMETER DIAGONAL DIMENSION DRAWING(S) DOWEL(S) EACH ELEVATION ELECTRICAL ELEVATOR ELECTRICAL METALLIC TUBING EDGE NAIL ENGINEER EQUAL EXPANSION (E) EXTERIOR FABRICATION(OR) FINISH FLOOR FINISH GRADE FINISH(ED) FLOOR FOUNDATION FACE OF CONCRETE FACE OF MASONRY FACE OF STUD FACE OF WALL FINISH SURFACE FOOT(FEET) FOOTING GROWTH (CABINET) GAUGE GALVANIZE(D) GROUND FAULT CIRCUIT INTERRUPTER GLUE LAMINATED BEAM GLOBAL POSITIONING SYSTEM GRND. HDR. HGR. HT. ICGB. IN.(") INT. LB.(#) L.B. L.F. L. MAS. MAX. M.B. MECH. MFR. MIN. MISC. MTL. (N) NO.(#) N.T.S. 0.C. OPNG. P/C PCS PLY. PPC PRC P.S.F. P.S.I. P.T. PWR. QTY. RAD.(R) REF. REINF. REQ'D. RGS. SCH. SHT. SIM. SPEC. SQ. S.S. STD. STL. STRUC. TEMP. THK. T.N. T.O.A. T.O.C. T.O.F. T.O.P. T.O.S. T.O.W. TYP. U.G. U.L. U.N.O. V.I.F. w WI WD. W.P. WT. ~ IP. GROUND HEADER HANGER HEIGHT ISOLATED COPPER GROUND BUS INCH(ES) INTERIOR POUND(S) LAG BOLTS LINEAR FEET (FOOT) LONG(ITUDINAL) MASONRY MAXIMUM MACHINE BOLT MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS METAL NEW NUMBER NOTTO SCALE ON CENTER OPENING PRECAST CONCRETE PERSONAL COMMUNICATION SERVICES PLYWOOD POWER PROTECTION CABINET PRIMARY RADIO CABINET POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED POWER (CABINET) QUANTITY RADIUS REFERENCE REINFORCEMENT(ING) REQUIRED RIGID GALVANIZED STEEL SCHEDULE SHEET SIMILAR SPECIFICATION(S) SQUARE STAINLESS STEEL STANDARD STEEL STRUCTURAL TEMPORARY THICK(NESS) TOENAIL TOP OF ANTENNA TOP OF CURB TOP OF FOUNDATION TOP OF PLATE (PARAPET) TOP OF STEEL TOP OF WALL TYPICAL UNDER GROUND UNDERWRITERS LABORATORY UNLESS NOTED OTHERWISE VERIFY IN FIELD WIDE(WIDTH) WITH WOOD WEATHERPROOF WEIGHT CENTERLINE PLATE ABBREVIATIONS NEW ANTENNA ,_:;;..:; (E) ANTENNA • • ~ [§] IT] v 0 ~ ~ & 0 GROUND ROD GROUND BUS BAR MECHANICAL GRND. CONN. CAD WELD GROUND ACCESS WELL ELECTRIC BOX TELEPHONE BOX LIGHT POLE FND. MONUMENT SPOT ELEVATION SET POINT REVISION GRID REFERENCE DETAIL REFERENCE po o o o o o o! ~o0 o 0 o0 o 0 o 0 o0 r l><I I~ GROUT OR PLASTER (E) BRICK (E) MASONRY CONCRETE EARTH GRAVEL PLYWOOD SAND WOOD CONTINUOUS WOOD BLOCKING STEEL CENTERLINE PROPERTY/LEASE LINE MATCH LINE l"~"....l-----WORK POINT -G --G -GROUND CONDUCTOR --T --T --TELEPHONE CONDUIT --c --C:--ELECTRICAL CONDUIT (POWER LINE) ~ ELEVATION REFERENCE --A--.A--COAXIAL CABLE ~ ~ ] I H OVERHEAD SERVICE C I CONDUCTORS : G=X-~~ SECTION REFERENCE -X --X -CHAIN LINK FENCING . ~ 2 1. THE FACILITY IS AN UNOCCUPIED DIGITAL TELECOMMUNICATION FACILITY. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATIENTION OF THE IMPLEMENTATION ENGINEER AND ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 7. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE IMPLEMENTATION ENGINEER AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. 8. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FIRE CODE APPROVED MATERIALS. 9. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 10. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 23 OF THE 2013 CBC REGARDING EARTHQUAKE PIPING. LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS AND MECHANICAL EQUIPMENT. ALL WORK MUST BE IN ACCORDANCE WITH LOCAL EARTHQUAKE CODES AND REGULATIONS. 11. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAYBE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 12. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, VEGETATION, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF VERIZON WIRELESS. 13. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 14. PENETRATIONS OF ROOF MEMBRANES SHALL BE PATCHED/FLASHED AND MADE WATERTIGHT USING LIKE MATERIALS IN ACCORDANCE WITH NRCA ROOFING STANDARDS AND DETAILS. CONTRACTOR SHALL OBTAIN DETAILING CLAR;FICATION FOR SITE-SPECIFIC CONDITIONS FROM ENGINEER, IF NECESSARY, BEFORE PROCEEDING. 15. BEFORE ORDERING AND/OR BEFORE FABRICATING/CONSTRUCTING/INSTALLING ANY ITEMS, VERIFY THE TYPES AND QUANTITIES. 16. CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE AND PAGER, AND KEEP SAME ON SITE WHENEVER PERSONNEL ARE ON SITE. 17. THE CONTRACTOR SHALL VERIFY ALL DIMENS:ONS AND CONDITIONS ON THE SITE AND NOTIFY THE PROJECT MANAGER OF ANY DISCREPANCES BEFORE STARTING ANY WORK. 18. CONTRACTOR TO PROVIDE COMPLETE SET OF AS BUILT DRAWINGS WITHIN 10 WORKING DAYS OF PROJECT COMPLETION. 19. CONTRACTOR IS TO EXCAVATE 6" BELOW EXISTING GRADE AND SPRAY WITH WEED CONTROL. REPLACE WITH CLASS II AGGREGATE BASE AND CRUSHED WASHED ROCK. AS SPECIFIED ON SITE PLAN. 20. CONTRACTOR SHALL PROVIDE TOILET FACILITY DURING ALL PHASES OF CONSTRUCTION. 21. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR THE FABRICATION OF MATERIALS TO BE INSTALLED AT THE SITE, THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS INCLUDING AS-BUILT DIMENSIONS OF EXISTING STRUCTURES OR STRUCTURAL ELEMENTS HAVING A BEARING ON THE SCOPE OF THE WORK TO BE PERFORMED. IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE DIMENSIONS OR CONDITIONS FOUND TO BE EXISTING IN THE FIELD, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND OBTAIN DESIGN RESOLUTION PRIOR TO PROCEEDING WITH THE PORTION(S) OF THE WORK AFFECTED. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO SO NOTIFY THE ENGINEER AND OBTAIN RESOLUTION BEFORE PROCEEDING. GENERAL NOTES 1 lt--------------------------------------------------------,---+----------------------------w_R_o_u_G_H_T_1R_O_N_F_E_N_c_1N_G ____ ~--l-------------------------------------------,--~ 4 3 NOT USED LEGENDS ~ ~ z.._~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~....i.~..i...~~~~~~~~~~~~~~~~~~~~~~~~...J..~.J....~~~~~~~~~~~~~~~~~~~~~~~~~---1, ..... -------------- ISSUE STATUS REV. DATE DESCRIPTION BY 0 05/20116 90% CONSTRUCTION LR 1 07/05116 100% CONSTRUCTION DJL 1~1 S RELIANT LAND SERVICES --------- 1745 W ORANGEWOOD AVE. STE 103 ORANGE, CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX (714) 453--9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED C ·-I.. z <( _J _J w _J () (.) ~ ~ 0 UJ => z UJ ~ z 0 >-z <( () 0 z <( CfJ I.O 0 I.O I.O ~ 0 I-0 ~~ s <( wz :::, 0::: zo W LL ~ <i! 0::: () w . ~o o<c: _J CD 0 CJ) ..-_J I'-0::: N <( () SHEET TITLE: co ~ co N O") <( () UJ z ~ GENERAL NOTES, LEGEND & ABBREVIATIONS T-2 I PROPERTY LINE \ I I I I I I I I I I I I I I I I I I \ \ EXISTING VERIZON WIRELESS AREA OF IMPROVEMENT ROOF PLAN ON SHEET A-2 FOR MORE INFORMATION (E) VERIZON WIRELESS ENCLOSED GENERATOR ---- iii .... ~ "' ' :: l [I) • Ill Ill • ! I 111 \ 1: Ill Ill Ill ! Ill I ' Ill Ii; [ 111 ' Ill 11111 Ill ill il!l' Ill 1i: Ill 1: 1. ill !II Ill !II ' Ill i r.l ill ' Ill I I _ __J ~,1 I. I I APN: 209-081-31 -... l I I I (E) CONCRETE CURB ! 0 .\ II 11 0 D 0 it J (E) PALM TREES (TYP.) ----------------- I -:t I / . .. :.'. /JJ I !, ;·. :: !];I ) ~ l1.·1 I / .• Ir·, I/,,../ . I I I ' I I !' ::/ I I .. 'I I I I /. ·/ I I I • ·1 1 1 . ' 1. I· .· .· j I I , f!sJ @ ~I I I I I g; ~I I I I I I (E) CONCRETE CURB, GUTTER AND SIDEWALK (TYP.) ISSUE STATUS REV. DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION LR 1 07/05/16 100% CONSTRUCTION DJL 1~1 S RELIANT LAND SERVICES 1 7 45 ·w oR·A·NGEWOOD AVE. STE i' o:i ORAN.GE. cA:92a~6a WWW.RLSUSA.COM PH. {714) 685-0123 FAX (714) 453-9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON W!RELESS IS STRICTLY PROHIBITED C ·-II. z <( _J _J w _J (.) u ~ ~ Cl w => z w ~ z 0 >-z <( (.) Cl z <( Cl) LO C) LO LO ~ 0 I-..... Cf) 0 w~ $ <( wz ::, a::: zo w LJ.. >- <( <i! a::: () w -~o o<C _J (D 0 Cf) ..... _J I'-a::: N <( () SHEET TITLE: SITE PLAN A-1 00 ~ (0 N 0) <( (.) w z ~ I .---------··-1 \ _J ---. ---I ----.. .J ------- (E) VERIZON WIRELESS ENCLOSED GENERATOR --- PROPOSED VERIZON---- WIRELESS REMOTE RADIO UNIT + A2. MODULE MOUNTED AT (E) EQUIPMENT SCREEN 00 - \ ------PROPERTY LINE -------- (E) VERIZON WIRELESS ROOFTOP EQUIPMENT PLATFORM .-(E) VERIZON WIRELESS RAYCAPBOX ------------ NEW A2. MODULE TO BE ADDED TO (E) VERIZON WIRELESS RRU (1 RRU ~ 3 SECTORS TOTAL.) \\!~\=\=fiiini.~§'faaaa~§!:!-/~·qi·~iii~fim ffri ~ (E) ROOF ACCESS I HATCH r ~ I ~ • -~ ,~~~--"·. ~'1 ~ "' . "' "' "' . "' "' "' " ' "' '"' " "'"' . "' 11 " "'1 . ' ". .... '-. .. --' ~-. ·-····' ··-· .... --~----· ~ .--, ______ t?=-::.\:, ' ··----·--·-" - SECTOR C 270° AZIMUTH l .... VERIZON WIRELESS ANTENNA MOD SEE ANTENNA PLAN "SECTOR" ON SHEET A·3 FOR MORE INFORMATION ---------------- i I J ( I \, C ' ' i I 1 I I r [&1 ·-·-• i re] [Ii] i. ': [Ii] i81 . ~ ~ II re] ,~: 1t l~~:\;,~~r ~ 1• • -~111-• 11[1] •I•\! 1[91 l9Ji ~I I I i • r.] i I r.i I I I I I ii ii 11 I\ I • I (E) ROOF VENT-~1 i1 1 ~(E) MECHANICAL SCREEN Ir WALL ii C (E) ROOF VENT_J (E) ROOF VENT-~ I ', lv-PROPOSED HYBRIFLEX 1 1 CABLES TO BE RUN WITHIN (E) I I ROOF MOUNTED CABLE TRAY l ~ I i J I I f -~~ ,-J' l , r J -- ,;-(E) BUILDING __/ / ROOFTOP PROPERTY L""IN=E- ---- (E) CONCRETE CURB VERIZON WIRELESS ANTENNA MOD SEE ANTENNA PLAN "SECTOR B" ON SHEET A-3 f---~ FOR MORE INFORMATION ---(E) PALM TREE (TYP.) VERIZON WIRELESS ANTENNA MOD SEE ANTENNA PLAN "SECTOR A" ON SHEET A-3 FOR MORE INFORMATION 00 U) 0 rTl 00 )> -I NO -Al ;;;:: C ISSUE STATUS REV. I DATE DESCRIPTION BY 0 05/20116 90% CONSTRUCTION I LR 1 07/05116 100% CONSTRUCTION DJL RELIANT LAND SERVICES 174s w ORANGEWOoD AVE.· sTE-103· 6RANG"E:· CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX !714) 453-9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED z <( ....J ....J w ....J u u ~ 0 f-..... Cl) 0 UJ ~ $ <( UJ z ::::> a::: zo UJ LL >- <( <i! a::: 0 ~o 0 <( _J CD 0 Cl) ..... _J r--. a::: C\I <( 0 SHEET TITLE: ROOF PLAN A-2 (E) VERIZON WIRELESS RAYCAP BOX TO REMAIN UNCHANGED VERIZON WIRELESS TO REMOVE AND REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) (E) VERIZON WIRELESS SCREEN BOX TO REMAIN UNCHANGED AT THIS ~---"s,---'~-~--SECTOR ~ (E) VERIZON WIRELESS RRU TO EXISTING SECTOR A /(E) VERIZON WIRELESS RAYCAP BOX TO I REMAIN UNCHANGED REMAIN UNCHANGED (1 RRU PER SECTOR, 3 SECTORS TOTAL) ~------(E) 5'-0" HIGH FRP SCREEN BOX TO REMAIN UNCHANGED (SEE ELEVATIONS FOR MORE INFORMATION) ~------PROPOSED VERIZON (E) VERIZON WIRELESS RRU TO•-- REMAIN UNCHANGED (1 RRU PER SECTOR, 3 SECTORS TOTAL.) VERIZON WIRELESS TO REMOVE AND--+-_/ REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL.) (E) 5'-0" HIGH VERIZON WIRELESS--- FRP SCREEN BOX TO BE REMOVED AND REPLACED WITH A PROPOSED 7'-0" HIGH FRP SCREEN TO MATCH (E) BUILDING (SEE ELEVATIONS FOR MORE INFORMATION) PROPOSED VERIZON --- WIRELESS REMOTE RADIO UNli' + A2 MODULE MOUNTED @@$RAP ET (N) A2 MODULE TO BE ADDED- TO (E) VERIZON WIRELESS RRU (1 RRU PER SECTOR, 3 SECTORS TOTAL.) ~ ~ ' . . WIRELESS REMOTE RADIO UNIT + A2 MODULE MOUNTED BEHIND (E) PARAPET ~~i4l;) . 1\\1)\lltlillillill\li~ ~ ANTENNA ANTENNA ANTENNA ~ SECTOR w AZIMUTH CENTERLINE ~ ~ 0 w ~ s z w SECTOR-A 80° 38' " 0 0 w u a 0 w " SECTOR-B 1so· 39' " ~ 0 j I, SECTOR-C 270° 37' z a g ~ MICROWAVE < ANTENNA u ~ ___.--PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN (E) SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) @ ,~~~~~~---------(NJ A2 MODULE TO BE ADDED ~ TO (E) VERIZON WIRELESS RRU (1 RRU PER SECTOR, 3 SECTORS TOTAL) PROPOSED SECTOR A 00 NUMBER OF ANTENNA COAX CABLE NUMBER OF HYBRID RAYCAP ANTENNAS TYPE CABLE LENGTH RRU +A2 FIBER SURGE &NUMBER NUMBER CABLES PROTECTOR 2 (2) 4' PANEL ANTENNA ±115' 2RRU+2A2 RADIOS 2 (2) 6' PANEL ANTENNA ±140' 2RRU+2A2 3 RADIOS 3 2 (2) 6' PANEL ANTENNA ±115' 2 RRU +2A2 RADIOS PROPOSED VERIZON WIRLESS -+-~ PANEL ANTENNA CONCEALED WITHIN PROPOSED SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) @ COMMENTS ~1-----+-----+----+-----+--------+------+----f------f------+------+------1 X ~ GPS " ANTENNA ~1----~---~----~---~-------+-----~----~----~----+-----~-----1 NOTE: CABLE LENGTH IS APPROXIMATE, CONTRACTOR TO FIELD VERIFY CABLE LENGTHS PRIOR TO ORDERING, FABRICATION, OR INSTALLATION OF CABLES. I k ,, L._---._--------,== (E) VERIZON WIRELESS RA YCAP BOX TO REMAIN UNCHANGED 3'-0" 5'-0" co UJ 0 111 ·o )> ---, NO -:::u :;;:: crn ---, I j, SECTOR C 270° AZIMUTH VERIZON WIRELESS TO REMOVE AND---~ REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) (E) 5'-0" HIGH VERIZON WIRELESS--~ FRP SCREEN BOX TO BE REMOVED AND REPLACED WITH A PROPOSED 7'-0" HIGH FRP SCREEN TO MATCH (E) BUILDING (SEE ELEVATIONS FOR EXISTING SECTOR B MORE INFORMATION) I k ,, '--.c--~------1-----(E) VERIZON WIRELESS RAYCAP BOX TO REMAIN UNCHANGED 3'-0" 5'-0" OJ UJ 0 111 'o )> ---, NO -:::u :;;:: cm ---, I l " ~--PROPOSED 7'-0" HIGH FRP SCREEN BOX TO REPLACE (E) 5'-0" SCREEN BOX PROPOSED SCREEN BOX TO MATCH (E) BUILDING (SEE ELEVATIONS FOR MORE INFORMATION) @ PROPOSED SECTOR B SECTOR C 270° AZIMUTH ANTENNA & CABLE SCHEDULE 2 ANTENNA PLAN 1~ ) i I EXISTING SECTOR C 1'-6" PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN (E) SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) @ ~--PROPOSED 7'-0" HIGH FRP SCREEN BOX TO REPLACE (E) 5'-0" SCREEN BOX PROPOSED SCREEN BOX TO MATCH (E) BUILDING (SEE ELEVATIONS FOR MORE INFORMATION) @ PROPOSED SECTOR C SCALE 1 /2"= 1' o" 5" 1 · 2' 4' 1 ISSUE STATUS REV .. DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION LR 1 I 01,05116 100% CONSTRUCTION DJL PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED ~ 0 w => z w 00 ~ ~ <O N z Ol 0 <( >-u z <( LU u z 0 > z 0:: <( en LO C> LO LO ~ 0 I-..-- 0 z Cf) N LU O') <( s <C LU Z _J :::) 0::: _J zo LU LL w ~~ _J 0::: () (.) LU -~o (.) 0 <C ~ ....Jen 0 Cf) ...I ..--0::: r--- N <C () SHEET TITLE: EXISTING AND PROPOSED ANTENNA LAYOUT, ANTENNA & CABLE SCHEDULE A-3 -·-···-~---------------~ -~-----------------~··-· ~-----·· 'l " " ~ t ~ ~ (E) VERIZON WIRELESS--, GENERATOR EXISTING WEST ELEVATION (E) VERIZON WIRELESS--, GENERATOR ' b ' io ' b ' io ' ' ' ' ' ' -' ~ (E) VERIZON WIRELESS~ /~--(E) SCREEN WALL EQUIPMENT (E) BUILDING ~ E]==~;I' ::::::::'.3=, =============::::::::'.===l' .. , .... ,.,., .. ,-,. ' --, ., .•. ' .. "' ' ,... .. ' ··-, . , .. , ---'-. - - I' -,:, ' :.[ ::1 :, -::: : (E) VERIZON WIRELESS EQUIPMENT 11 I " ' ,,,,,, ' (E) BUILDING--~~ . :.:.::,·, . .' .... :'.:.:., ' ' ,, ,, ' ' i! ' :, ' ' : '.:~ .. --· ,, . ·r ·; ., -· ., ... _ ' - ,: ' •••• " ' ,-,,-.. ,-,· ,., ... , '-.. : :: . ' ,' I ''' ' ' ,---c ' ::,:.,:.:::.:·1-,: I ' I I I ' ' ' '' : ,, ' ' ' ... :·:.;:.: .... , .. ' -··::, .. '"• ::::,: ! ::· I i ~- ' ' ' '_/ i _,;_~ '··' /,. ..... , .... ,,,. , ... , .. , ., ,,-,., ·, -'''' ' ,_,. _, ::, :1 .. ::i ' '·'· ' .. --,'-,'--, ==== : .. ., .. ;:c· ::::1::::.:.:· '.1.:.:,:::· ." .-. n .. ,,,.,. , ..... ,: __ , .. ,·· - ,'- ,---, :.:::_;···· ~ I : i:::. -'--,--'-. ::. i::':. _,_ --"' ; I •' ' -,-- '" ···-· ' -, ,,, ' ' ' ' I ' ' " " I ,, ,, ' '·· '' ·'·--···--'---·--·-- ' Ii 1: ' I - :;:r-;:r :r ··,·::;:_:;::::;: :; '-,-- ... :;···:::· -:r:;:r:1::;::c -. ~ •. ; ... ":.:::.: ,-.... ,.,,· .. ,. :·····,···· ,, '.: .] .. , ' ~ ;:· _,,,. ,-,, -,. ' -, .... , ... _' ·-· ·,·:::'T_:s.':_,:_:, '"'.'r::1'.r ' ' - - ' ,, - .. , .. ,..,. ' ,, ' I ,,,., i ,., .. , .... , '·-'-- :::,.:,.:;,,,, I ,, " ' j! ,, i' I i i - ,, 1! I' --,_ - ,',, ' ' ·:: . .:;-::.;:::·.:::·::::;,·:.;:::.: I ,_ ,,, '' :, -'fll , ~ I ' ' ' ' I ., .. ' ' .,, '"' --·-· --·--" -- -,, ' ~T ::c :\. ::c :; : . : ,,,; ' : ' - ... , .. ,_ ' ~--VERIZON WIRELESS TO REMOVE AND REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) TOP OF (E) BUILDING ELEV. 40'-0" AGL _______________ (§) VERIZON INIRELESS P~NEL ANTEN_IIJA CENTER~NE_ca. ELEV. 38'-0" AGTV "'---(E) 5'-0" HIGH VERIZON WIRELESS FRP SCREEN BOX TO BE REMOVED AND REPLACED WITH A PROPOSED 7'-0" HIGH FRP SCREEN TO MATCH (E) BUILDING ~--(E) PALM TREES SCALE 1 /8"= 1' ~--PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN PROPOSED SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) @ FINISH GRADE ELEV. 0'-0" AGL ~ o" 2' 6' 14' TOP OF /El BUILDING -------- ELEV. 40'-0" AGL PROPO~ED VERIZO_!'.I WIRELESS_PANEL ANT~NNA CENT~RLINE f111t, ELEV. 37'-0" AGCV PROPOSED 7'-0" HIGH FRP SCREEN BOX TO REPLACE (E) 5'-0" SCREEN BOX PROPOSED SCREEN BOX TO MATCH (E) BUILDING GI~ (E) PALM TREES FINISH GRADE ELEV. 0'-0" AGL 2 ~t------------------------------------------------------------------------------------~-------------------------------------------------------------------------,-----1 ~ SCALE i PROPOSED WEST ELEVATION 118 .. =1, ..... ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~....:.~~..:..~~~~~~~..,___. 2 @W,:001 o" 2' 6' 14' ------------------------ ISSUE STATUS REV. DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION LR 1 07/05/16 100% CONSTRUCTION DJL PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED C ·-I.. z <( .....I .....I w .....I (.) (.) ~ I- C/) w s ~ 0 LU :::, z LU ~ z 0 >-z <( 0 0 z <( Cf) LO C) LO LO ~ 0 ..-- 0 N O') <( wz => 0::: zo W LL ~~ 0::: (.) w -~o 0 <( ...J co 0 Cl) ..--...J I'--0::: N <( (.) SHEET TITLE: ELEVATIONS A-4 00 ~ = N O> c5 LU z fi: VERIZON WIRELESS TO REMOVE AND-----~ REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) (E) 5'-0" HIGH VERIZON WIRELESS-----~ FRP SCREEN BOX TO BE REMOVED AND REPLACED WITH A PROPOSED 7'-0" HIGH FRP SCREEN TO MATCH (E) BUILDING TOP OF E BUILDING ELEV. 40'-0" AGL NI_ENNA CENT_f:RLINE _ ~) VERIZON WIRELESS PANEL ---------0 ' LEV. 38'-0" AGL in EXISTING SOUTH ELEVATION PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN PROPOSED SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL.) @ TOP OF E BUILDING ELEV. 40' -0" AGL ~OSED VERIZON WIRELESS PANEL EN1'JA CENTERLINE _ . 37'-0" AGL PROPOSED 7'-0" HIGH FRP SCREEN BOX TO REPLACE (E) 5'-0" SCREEN BOX PROPOSED SCREEN BOX TO MATCH (E) BUILDING @ : ! iL 'ii (E) VERIZON WIRELESS EQUIPMENT (E) SCREEN---, ' #[ # I # # # # ;ti # (E) VERIZON WIRELESS- EQUIPMENT (E) SCREEN---- # # # # # # # i # # # I/ #:, -~- I # # # # # # ;ti # I .. .,.. " # # # # # ::11 # #] # # ' # # # # I I i I J ___ ----- # # # #j I ti # # # # # I ' # ' # ti # # # # # #1 ' I ! I ! I ,- #' -···------ ' --' in # # 'it::1 ;;111. # # I ' I ·······• L --- # # .# # # # -. I -- ti # # i ,t # # /; . #!1 ! I • ! - ' - # " /; I ·-·._ .. ·-····'·~·-· '-'-"····--·· ... ·------• .. · .... .' .... '---'-"····' - ~-~ VERIZON WIRELESS TO REMOVE AND REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL.) TOP OF (E) SCREEN WALL ELEV. 42'-0" AGL (E) _IIERIZON Wl~ELESS PAN_EcL ANTENNAGENTERLIN_§~ ELEV. 40'-0" AGL (E) 5'-0" HIGH VERIZON WIRELESS FRP SCREEN BOX TO BE REMOVED AND REPLACED WITH A PROPOSED 7'-0" HIGH FRP SCREEN TO MATCH (E) BUILDING (E) BUILDING SCALE 3/16"=1' ~--PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN PROPOSED SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL.) @ TOP OF E BUILDING ELEV. 42'-0" AGL 2 ___ __PROPOSED _IIERIZON Wl_l~ELESS PAN_§L ANTENN~ CENTERLl~E~ ELEV. 39"-0" AGLV "------PROPOSED 7'-0" HIGH FRP SCREEN BOX TO REPLACE (E) 5'-0" SCREEN BOX PROPOSED SCREEN BOX TO MATCH (E) BUILDING @ -------(E) PALM TREES -------------- ISSUE STATUS REV. I DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION ' LR 1 07/05/16 100% CONSTRUCTION DJL RELIANT LAND SERVICES -. 1745 W ORANGEWOOD AVE.STE 103 ORANGE. CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX (714) 453--9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED JN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS JT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED z <( ....I ....I w ....I () (.) ~ ~ D LU ::::> z LU ~ z 0 >-z <( () D z <( en Lt) c:, Lt) L!) ~ 0 I-0 ~~ s <( wz ::> 0::: zo w u. >- <( ~ 0::: (.) w -~o o<C .....J cc 0 (/) T""" .....J I'--0::: N <( (.) SHEET TITLE: ELEVATIONS A-5 00 ~ co N O') <( () u.r z ii: VERIZON WIRELESS TO REMOVE AND1------~ REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) r. TOPOF(£)~B~U~IL-D~IN~G~--~ VTl.EV. 40'-0" AGL (It. (E) VERl~ON WIRELE~S PANEL Af'JTENNA CE!i_TERLINE ___ _ V ELEV. 38'-0" AGL (E) 5'-0" HIGH VERIZON WIRELESS-------~ FRP SCREEN BOX TO BE REMOVED AND REPLACED WITH A PROPOSED 7'-0" HIGH FRP SCREEN TO MATCH (E) BUILDING EXISTING EAST ELEVATION PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN PROPOSED SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) @ TOP OF E] SCREEN WALL ELEV. 40'-0" AGL Ill I r. PRQPOSED VE~ZON WIRE~SS PANEL ~NTENNA C~TERLINE ____ _ ~LEV. 38'-0" AGL (It. PROPOS!cD VERIZOl'i_ WIRELESS !'.ANEL ANTE~NA CENTEB,LI_N_E __ ~ V ELEV. 37'-0" AGL PROPOSED 7'-0" HIGH FRP SCREEN-------~ BOX TO REPLACE (E) 5'-0" SCREEN BOX PROPOSED SCREEN BOX TO MATCH (E) BUILDING @ "J !f !f !f VERIZON WIRELESS TO REMOVE AND REPLACE (E) PANEL ANTENNA WITH PROPOSED PANEL ANTENNA (2 ANTENNAS PER SECTOR, 3 SECTORS TOTAL) (E) 5'-0" HIGH VERIZON WIRELESS FRP SCREEN BOX TO REMAIN UNCHANGED ;:fl··· !f !f ' !f PROPOSED VERIZON WIRLESS PANEL ANTENNA@ CONCEALED WITHIN (E) SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL} -7 ---(E) 5'-0" HIGH VERIZON WIRELESS FRP SCREEN BOX TO REMAIN UNCHANGED ... LC~ I ' ,-#! (E) VERIZON WIRELESS EQUIPMENT (E) SCREEN (E) BUILDING (E) VERIZON WIRELESS EQUIPMENT (E) SCREEN (E) BUILDING ~---(E) PALM TREE (TYP.) (E) VERIZON WIRELESS GENERATOR ~---(E) PALM TREE (TYP.) (E) VERIZON WIRELESS GENERATOR SCALE 3/16"=1' 0"1' 3' 7' ', __ " ----------------------- 2 ISSUE STATUS REV. DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION LR 1 07/05/16 100% CONSTRUCTION DJL I~IS RELIANT LAND SERVICES -' 1745 W ORANGEWOOD AVE. STE 103 ORANGE, CA 92868 WWW.RLSUSA.COM PH. {714) 685-0123 FAX (714) 453-9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS 1$ PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED z <( .....J .....J w .....J () (.) ~ ..... 0 w ::::> z w ;;'; z 0 >-z c3 0 z <( Cf) LO C) LO LO ..... 0 I-...... Cl) 0 w~ 5 <( wz ::::, 0::: zo W LL ~~ 0::: (.) w -~o o<C .....J CD 0 Cl) ...... .....J r--. 0::: N <( (.) SHEET TITLE: ELEVATIONS A-6 co ..... c.o C'-1 O") <( u w z ~ SCALE NTS SCALE NTS SCALE NTS 6 7 ~--BOLT ASSEMBLY TWO-PIECE BRACKET (TYP OF 2) ---._ ___ UNISTRUT P3000HS WITH P1012S CHANNEL NUTS OR EQUIVALENT (TYP.) "-----PROPOSED RRU-12 @ ~--BOLT AT 2'-0" SPACING RRU + A2 MOUNTING DETAIL SCALE NTS I I " ' SBNHH-1 D65A RADOME MATERIAL: RADOME COLOR: DIMENSIONS, HxWxD: WEIGHT, WITHOUT MOUNTING: WIND LOADING, MAXIMUM: WIND SPEED, MAXIMUM: CONNECTOR: ANTENNA SPECIFICATIONS ...... I I 7.1,, I . m N >- I I SBNHH-1D65B RADOME MATERIAL: RADOME COLOR: DIMENSIONS, HxWxD: WEIGHT, WITHOUT MOUNTING: WIND LOADING, MAXIMUM: WIND SPEED, MAXIMUM: CONNECTOR: ' ~ I 119" , ------ - ------------------~-------- FIBERGLASS, UV RESISTANT LIGHT GRAY 55.0 X 11.9 X 7.1 in (1398 x 301 x 180 mm) 33.5 lbs (15.2 kg) 445.0 N @ 150 KM/H 100.0 LBF @ 150 KM/H 241.4 KM/H / 149.8 MPH 6 x 7-16 DIN FEMALE SCALE NTS FIBERGLASS, UV RESISTANT LIGHT GRAY 72.9 X 11.9 X 7.1 in (1851 x301 x 180 mm) 40.6 lbs (18.4 kg) 618.0 N @ 150 KM/H 138.9 LBF @ 150 KM/H 241 KM/H / 150 MPH 6 x 7-16 DIN FEMALE SCALE NTS 3 4 5 NEW 1/2"0 THREADED ROD C/W NUTS & WASHERS (TYP.J---~ NEW ANTENNA MOUNTING PIPE (TYP.)---------1 NEW ANTENNA MOUNTING BRACKET PER ANTENNA MANUFACTURER'S SPECS. (TYP) T--Jiit--~-NEW t"0 MACHINE BOLTS C/W NUTS & WASHERS (TYP.) NEW PANEL ANTENNA (TYP.) NEW ANTENNA MOUNTING BRACKET PER ANTENNA MANUFACTURER'S SPECS. (TYP) NEW i"0 MACHINE BOLT C/W NUT & WASHER (TYP.) ANTENNA, RRU & A2 MOUNTING DETAIL ERICSSON RRUS-12 W/ A2 RX-ONLY MODULE DIMENSIONS, HxWxD: 20.4"x18.5"x10.9" PROPOSED RRUS-12-- POWER CONSUMPTION: 200 WAITS TOTAL WEIGHT: 72 LBS TEMPURATURE: -40" TO 55" C PROPOSED RRUSA2 18.5" I 15.1" j i .,r-1v ___ -ic1v I .,. ";<---'---'cmrmmrr'mm'n1 I ~ .,_--,~~~~~~~ DDODDDOC~DODDDCOQOJDD ::n I "' I ~'i,;.----1!':1==~=========~ = i d) Ni I I J " BAND PRODUCT NAME PRODUCT NUMBER TX POWER RX8RANCHES DIMENSIONS (HxWxD) WEIGHT SW DEPENDENCY 10.9" 7.3" I< r V '1 ~. I~~~-'. i L__NEWA2 MODULE RRUSA2 DATA PCS RRUSA2 82 KRC 161 285/1 N/A 2 16.4"x15.1 "x3.4" 22 lbs L13A AWS RRUS A2 81 KRC 161 290/1 NIA 2 16.4"x15.1 "x3.4" 22 lbs L13A 15.1" i -)'- ! 1.-L--"---~-'-. ! RRUS-12 + A2 MODULE SPECIFICATIONS -------------------------- SCALE NTS PROPOSED RRUSA2 1 PROPOSED RRUS SCALE NTS 2 ISSUE STATUS REV. DATE DESCRIPTION j BY 0 05/20/16 90% CONSTRUCTION I LR 1 · 07/05/16 100% CONSTRUCTION DJL RELIANT LAND SERVICES . 17 45 W ORANGEWOOD AVE. STE l 03 ORANGE, CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX [714] 453-9692 PROPRIETARY INFORMATION THE JNFORMATJON CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED z <( ....I ....I w ....I (.) (.) ~ ~ Cl w :::, z w ~ z 0 >-z <( (.) Cl z <( Cf) LO C) LO LO ~ 0 I-T""" U)o w~ s <( wz ::, 0::: zo w LJ.. >- <( ~ 0::: u w ~ ~o 0 <( ...J co 0 U) T""" ...J f',... 0::: N (5 SHEET TITLE: 00 ~ co N 0) c3 w z > 0:: SPECIFICATIONS A-7 ~ ~ " ~ 0 ~ " GROUNDING NOTES: • I • #2 AWG BCW TO ANTENNA GROUND BAR AT SECTOR 'ALPHA' ~--PROPOSED VERIZON WIRELESS REMOTE RADIO UNIT + A2 MODULE MOUNTED BEHIND (E) PARAPET -7~----PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN (E) SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL.) '"'-------"'--"'--....__ (E) VERIZON WIRELESS RRU TO REMAIN UNCHANGED (1 RRU PER SECTOR, 3 SECTORS TOTAL.) ~----#2 AWG BCW GROUND WIRE (TYP.) ~----(E)GROUNDBAR PROPOSED VERIZON---~ WIRELESS REMOTE RADIO UNIT+ A2 MODULE MOUNTED BEHIND PANEL ANTENNAS (E) VERIZON WIRELESS RRU TO-- REMAIN UNCHANGED (1 RRU PER SECTOR, 3 SECTORS TOTAL.) PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN PROPOSED SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL.) PROPOSED SECTOR A PROPOSED VERIZON---~ WIRELESS REMOTE RADIO UNIT+ A2 MODULE MOUNTED BEHIND PANEL ANTENNAS (E) VERIZON WIRELESS RRU TO~ REMAIN UNCHANGED (1 RRU PER SECTOR, 3 SECTORS TOTAL.) #2 AWG BCW GROUND WIRE-~ (TYP.) (E) GROUND BAR------- #2 AWG BCW G OUND WIRE-~ (TYP.) ,_,_,_,_,_,_,_,_,_,_, INSTALL THEFT DETERRENT COMPOSITE GROUNDING CABLES FOR ELECTRICAL DISTRIBUTION GROUNDING LEAD WHERE COPPER THEFT MAY OCCUR BY ERICO OR APPROVED EQUAL (www.erico.com) ·"· • \., ·--/ • PROPOSED SECTOR B • I i • • I • I • • •-•-•-•-• "" ..._ .... \ ' 0 \ I \ I I I I I I ! Ii I •-•-•-•-•-•-• #2AWGBCWTO ANTENNA GROUND BAR AT SECTOR 'BETA' (E) GROUND BAR ~-#2 AWG BCW GROUND WIRE (TYP.) #2 AWG BCW TO--~ ANTENNA GROUND BAR AT SECTOR 'GAMMA' • • ,, ......-· ,..... .--·,J--:· ~-·--·-11--·-·-·-·---· ' • ........ L.J ~~~~~I . -.... __ I i • I ~-#2 AWG BCW GROUND WIRE (TYP.) PROPOSED VERIZON WIRLESS PANEL ANTENNA CONCEALED WITHIN (E) SCREEN BOX (1 ANTENNAS PER SECTOR, 3 SECTORS TOTAL.) PROPOSED SECTOR C ~t--------------------------------------------------------------------------------------------------------------------,"'7 ~ SCALE VM l'/ff/@ d 1 ;L-_A_N_T_E_N __ N_A __ G_R_o __ u_N_D_i_N_G __ P_L_A_N __________________________________________________________________________________________________ ~N~OR-TH~-31_4,,_=1~. _d_:;_~,, __ t_W_Wh_w;_· ...... -- ------------------------------------------------- ISSUE STATUS REV. DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION LR 1 07/05116 100% CONSTRUCTION DJL 1745 W ORANGEWOOD AVE. STE 103 ORANGE.CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX (714) 453-9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED z <( .....J .....J w .....J (.) u ~ ~ 0 UJ ::, z UJ ~ z 0 >-z <( C.) 0 z <( CJ) l!) C) l!) l!) ~ wz :::, 0::: zo W LL ~~ 0::: (.) w 0-~ 0 <{ .....J co 0~ ..-0::: ~ <{ (.) SHEET TITLE: co ~ CD N O> <( C.) UJ z ~ EQUIPMENT & ANTENNA GROUNDING PLANS G-1 SCALE NTS 7 SCALE NTS 5 ~ ~ BOLT GRND. ROD CLAMP 2 HOLE LUG "U" BOLT PIPE CLAMP 2 BOLT PARALLEL CROSS RUN SPLICER CLAMP V UNIVERSAL PIPE CLAMPS 75/1.25 CAST 'T' SPLICER 1 BOLT PARALLEL ~ CLAMP 1 BOLT PARAI LEL CLAMP UNIVERSAL PIPE CLAMPS 50H2 MECHANICAL CONNECTION SCALE NTS 2 GROUNDING NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. SUBCONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT JS NOT BLOCKED. 3. THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 4. SERVICE TO EQUIPMENT CABINETS SHALL BE 120/240 VAC, 200A, 1-PHASE, 3 WIRE. 5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. 7. THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE (E) FACILITY GROUNDING SYSTEM AND LIGHTNING PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THE AHJ), THE SITE-SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. 8. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. l------------------------1.---1.--+-----------------------,..__ __ ,..___--t-------------------------'-----'-------j 9. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL RESISTANCE TO SCALE NTS SCALE NTS ------------------ 8 9 SCALE NTS SCALE NTS 6 7 TYPE SS TYPE TA TYPE VB TYPE XA TYPE GT TYPE LJ TYPE HA TYPE VS TYPE PG TYPE GR TYPE PC CADWELD CONNECTIONS TYPE PH TYPE NC TYPE NX1 TYPE RR SCALE NTS SCALE NTS 3 4 ----------------'" ------~· EARTH TESTING (PER IEEE 1100 AND 81) FOR (N) GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 10. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 11. EACH INDOOR BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 AWG OR LARGER. 12. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 13. APPROVED ANTIOXIDANT COATINGS (J.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. ALL OUTDOOR METAL SUPPORT POSTS FOR ICE BRIDGE AND TRAY SHALL BE BONDED TO THE (E) BURIED GROUND ELECTRODE SYSTEM WITH A SINGLE CONDUCTOR #2 AWG SOLID TINNED COPPER WIRE. 16. SURFACES TO BE CONNECTED TO GROUND CONDUCTORS SHALL BE CLEANED TO A BRIGHT SURFACE AT ALL CONNECTIONS. 17. EXPOSED GROUNDING CONNECTIONS SHALL BE MADE WITH COMPRESSION CONNECTORS WHICH ARE THEN BOLTED TO EQUIPMENT USING STAINLESS STEEL HARDWARE. INSTALLATION TORQUE SHALL BE PER MANUFACTURE'S REQUIREMENT. 18. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC (CADWELD) CONNECTIONS. 19. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 20. GROUND RODS SHALL BE COPPER CLAD STEEL, 5/8"010-FT. LONG, AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. 21. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITIED. 22. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 23. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. TESTING SHALL BE PERFORMED IN ACCORDANCE WITH PROJECT SPECIFICATION FOR FACILITY GROUNDING, USING FALL OF POTENTIAL METHOD. 24. BOND ALL METALLIC OBJECTS WITHIN 6FT OF MAIN GROUND WIRES WITH -#2 AWG TIN-PLATED COPPER GROUND CONDUCTOR. 25. INSTALL THEFT DETERRENT COMPOSITE GROUNDING CABLES FOR ELCTRICAL DISTRIBUTION GROUNDING LEAD WHERE COPPER THEFT MAY OCCUR. GROUNDING NOTES ----·'"··· --- SCALE NTS 1 ISSUE STATUS REV. i DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION LR 1 07/05/16 100% CONSTRUCTION DJL ; ; l~.l s RELIANT LAND SERVICES ..41111 .. i 1 J I 11 .. 11 .. 1745 W ORANGEWOOD AVE. STE 103 ORANGE, CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX (714] 453-9692 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS !T RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED C ·-1. z <( .....I .....I w .....I (.) (.) ~ 0 I-0 ffJ ~ $ <( wz ::J 0::: zo W LL ~ <i! 0::: () w ~ ::::i:::o o<r: _J aJ 0 Cl) _J ..--0::: ~ <( () SHEET TITLE: GROUNDING DETAILS G-2 1 . 2. 3. 4. 5. 6. FRP NOTES GENERAL FIBERGLASS NOTES 'FRP' OR 'FG' REFERS TO FIBERGLASS MATERIAL. ALL FRP MATERIAL TO BE PER LARR#25536 BY "FIBERGRATE COMPOSITE STRUCTURES" OR EQUAL. MINIMUM STRENGTH AS FOLLOWS: TENSILE LENGTHWISE: TENSILE MODULUS: FLEXURAL LENGTHWISE: FLEXURAL MODULUS: SHEAR: Yz" FIBER BOLT BEAR'G: LENGTHWISE: CROSSWISE: 5,350 PSI 3.48 X1 OE6 PSI 6,685 PSI 2.54 X 1 OE6 PSI 930 PSI 5,150 PSI 1,980 PSI ALL HOLES UNLESS NOTED OTHERWISE, SHALL BE PUNCHED OR DRILLED 1 /16" LARGER IN DIAMETER OF THE BOLTS THEY RECEIVE. APPLY FIBERGLASS ADHESIVE IN BOLTING APPLICATION TO SEAL BOLT HOLES. FIBERGLASS ADHESIVE: ALL CONTACT SURFACES OF FRP STRUCTURAL SHAPES AND/OR HYBRID POLYMER COMPOSITE ARCHITECTURAL PANELS SHALL BE BONDED AS INDICATED ON THESE DRAWINGS WITH THE MANUFACTURER'S APPLICATION INSTRUCTIONS. LIQUID NAILS MULTIPURPOSE CONSTRUCTION ADHESIVE BY MACCO. BONDING SURFACES SHALL BE CAREFULLY PREPARED TO ENSURE A GOOD ADHESIVE BOND AS FOLLOWS: WIPE CONTACT SURFACES WITH A SOLVENT (STYRENE, TOLUENE OR METHYL (ALCOHOL)). REMOVE SURFACE GLOSS BY LIGHT SANDING, APPLY A ADHESIVE, FASTEN OR CLAMP BONDING SURFACES UNTIL CURED. ALL EXPOSED JOINTS AT ARCHITECTURAL PANELS AND SHAPES (EDGES CORNERS, ETC.) SHALL BE CAULKED WITH AN APPROVED FLEXIBLE POLYURETHANE SEALANT/ CAULK. SCREEN COVER TO BE%" THK FRP SHEET W/ %"¢ FIBER BOLT TO FRAM'G @ 1 o" O.C. ALL EDGES. PER ARCHI COVERED W/ FOAMED "EFIS" SYSTEM TO MATCH (E) BLDG. ALL CONNECTIONS TO BE (2)-%"¢ FIBER BOLTS. I I . I I ! I I I I I I I I I I I I I I I I I I I I /I I I I / p: ;1 ! Ii I I JI I I I I I I I / I I Ill I i I I I I I VERT & HORIZ LEDGER ANCHORED TO WALL PER APPLIED DET'L ANTENNA SCREEN SECTION SCALE NTS SCALE NTS 3 4 ,, ,_)) "J DASH LINE APPLY TO 6' -0" 0 P---....+-+------'lr-\----l--+-if---~ OVER FULL HT SCREEN ONLY: PROVIDE C4X1% FRP STUD @ 24" O.C. W/ L3X3~ FRP CLIP & (2)-%"¢ FIBER BOLTS TO T&B GIRTS. HORIZ CORNER BRACES-~ T&B TYP EVERY BAY PROVIDE POSITIVE CONNECTION --~c BETWEEN VERT & HZ LEDGER TO WALL ELEMENT FRAMING NOTES: 1. ALL VERT & HZ FRAMING MEMBERS TO BE L4X4X% FRP ANGLES U.N.O. ALL DIAGONAL BRACES TO BE L3X3~ FRP ANGLES, U.N.O. 2. ALL CONNECTIONS TO BE (2)-%"¢ FIBER BOLTS. 3. SCREEN COVER TO BE %" THK FRP SHEET W/ EPOXY GLUE & Yz"¢ FIBER BOLT TO FRAM'G @ 1 O" O.C. ALL EDGES. OPTIONAL COVER FIN W/ FOAMED "EFIS" SYSTEM TO MATCH (E) BLDG. WALL MOUNTED FRP ANTENNA SCREEN LEDGER DETAIL ·) ) 3Yz" MIN EMBD r;;. B 6" OVERHANG WHERE REQ'D ~ -w------ + I \~ -~ ,i -~ I i CD WOOD/METAL STUD ®METAL STUD G)oPTION CD 0 0 0 ® ANCHOR BOLT: %"¢ LAG BOLT @ 24" O.C. MIN (3)-A.B. PER LEDGER BACKING: 4X6 BLK'G W/ A35 @ B.SIDES & B.ENDS. USE #10 TEK SCREW @ METAL STUDS. ANCHOR BOLT: (2)-Xi"¢ SELF-DRILLING SCREWS OR (1 )-Yz"¢ THRU BOLTS @ 16" O.C. BACKING: UNISTRUT P1000 SPAN MIN (2)-STUDS @ 24" O.C. W/ Yz"¢ M.B. TO LEDGER. OFFSET MOUNT WHERE FLUSH LEDGER IS REQ'D. L3X3~ BACKING B.SIDES SPANING OVER MIN (2)-(E) STUDS W/ %"¢ THRU BOLTS. PROVIDE %"¢ LAG BOLT @ WOOD OR Xi"¢ TEK SCREW @ METAL STUD TO SECURE ANGLE BACK'G LEDGER FRAMING PER PLAN, L4X4X% FRP ANGLE U.N.O. WALL SHT'G & FINISH TO BE FIELD VERIFIED. LEDGER TO BE INSTALLED ON SOLID FIRM BACK'G. REMOVE SOFT MATERIAL SUCH AS FOAM BOARD AT LEDGER LOCATION OR PROVIDE 2"¢ STL PIPE SPACER @ EA A.B. SEE DET'L 6. WATERPROOFING TO BE PROVIDED BY G.C. AT ALL (E) WALL PENETRATION. ---------·------ X <( 2 -0 I OCJ I u 0:: <( 0:: w Q_ f- I SCALE NTS SCALE NTS 1 2 ISSUE STATUS REV. 1 DATE DESCRIPTION BY 0 05/20/16 90% CONSTRUCTION . LR 1 · 07/05/16 100% CONSTRUCTION DJL 1745 W ORANGEWOOO AVE.STE 103 ORANGE. CA 92868 WWW.RLSUSA.COM PH. (714) 685-0123 FAX {714) 453-9692 PROPRIETARY INFORMATION THE INFORMAT!ON CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED C ~ Cl w ::> z w co ~ ~ co N z 0, 0 <( >-(.) z ·-<( w (.) z I.. Cl > z 0::: <( (/) LO C) LO LO ~ 0 I-..-- 0 z Cl) N w O') <( $ <( wz _J ~ c::: _J zo W LL w ~ :;i _J c::: () u w -~o (.) 0 <( ~ ...J Cil 0 Cl) ...J ..--c::: r--. N <( () SHEET TITLE: FRP SCREEN BOX DETAILS S-1