Loading...
HomeMy WebLinkAboutCD 2018-0010; SQUIRES DAM COMMUNICATION SITE; Consistency DeterminationABBREVIATIONS ABV. ABBREVIATION EQ. EQUAL MECH. MECHANICAL AC ACOUSTIC(AL) EQUIP. EQUIPMENT MET. METAL A/C AIR CONDITIONING EXIST. EXISTING MIN. MINIMUM ALT. ALTERNATE EX. EXTERIOR MISC. MISCELLANEOUS ALUM. ALUMINUM F.S. FACE OF STUD NAT. NATURAL A.B. ANCHOR BOLT FIN. FINISH N. NORTH APPROX. APPROXIMATE FIX. FIXURE N.I.C. NOT IN CONTRACT ARCH. ARCHITECT(URAL) FL. FLOOR N.T.S. NOT TO SCALE A.C. ASPHALTIC CONCRETE F.L. FLOW LINE O.C. ON CENTER BM. BEAM F.D. FLOOR DRAIN 0.0. OUTSIDE DIAMETER BLK(G) BLOCKING FLOUR. FLOURESCENT OPNG. OPENING BD. BOARD FT./ FOOT PER OPP. OPPOSITE BOT. BOTTOM FTG. FOOTING PL. Pl.ATE BLDG. BUILDING FON. FOUNDATION PLYWD. PLYWOOD CAB. CABINET GAL. GALLON REINF. REINFORCE(ING) C.I. CAST IRON GALV. GALVANIZED RM. ROOM C.B. CATCH BASIN G.I. GALVANIZED IRON SCHED. SCHEDULE CLG. CEILING SEC. SECTION G. GAS CEM. CEMENT SHT. SHEET GA. GAUGE CER. CERAMIC SIM. SIMILAR GL. GI.ASS C.O. CLEAN OUT S. SOUTH CLR. CLEAR G.L. GLUED LAMINATE SPECS. SPECIFICATIONS COL. COLUMN GYP. GYPSUM SQ. SQUARE CONC. CONCRETE HT. HEIGHT STD. STANDARD CONN. CONNECTION H.M. HOLLOW METAL STL. STEEL CONT. CONTINUE(OUS) HORIZ. HORIZONTAL STRUCT. STRUCTURAL DET. DETAIL H.B. HOSE BIBB SUSP. SUSPENDED DIAM. DIAMETER INFO. INFORMATION T & p TELEPHONE & POWER DIM. DIMENSION I.D. INSIDE DIAMETER THK. THICK DR. DOOR INSUL. INSUI.ATE(ION) T & B TOP & BOTTOM DBL. DOUBLE INT. INTERIOR TYP. TYPICAL DN. DOWN JT. JOINT U.N.0. UNLESS NOTED OTHERWISE DS. DOWN SPOUT KIT. KITCHEN VENT. VENTILATION DWG. DRAWING I.AB. LABORATORY VERT. VERTICAL D.F. DRINKING FOUNTAIN LT. LIGHT W. WATER EA. EACH LIN. LINEAL WT. WEIGHT E. EAST MFR. MANUFACTUR(ER'S) W.W.M. WELDED WIRE MESH ELEC. ELECTRIC(AL) M.O. MASONRY OPENING w. WEST EL. ELEVATION MAT. MATERIAL W/ WITH ENCL. ENCLOSURE MAX. MAXIMUM WD. WOOD PROJECT DESCRIPTION MODIFICATION OF AN EXISTING UNMANNED VERIZON WIRELESS COMMUNICATIONS SUBSTATION TO CONSIST OF THE FOLLOWING: 1. THE RELOCATION OF SIX (6) EXISTING PREVIOUSLY APPROVED PANEL ANTENNAS ON AN EXISTING TOWER TO BE INSTALLED ON NEW DUAL MOUNT BRACKET (TYP. OF 2 PER SECTOR). 2. REMOVAL OF THREE (3) EXISTING RAYCAPS, ONE (1) AT EACH SECTOR 3. INSTALLATION OF (3) RRUS (B5) COMBO UNITS FOR 850-LTE. 4. INSTALLATION OF (3) RRUS (813) COMBO UNITS FOR 700-LTE. 5. RELOCATE (E) 3315 RAYCAP TO BETA SECTOR. 6. INSTALLATION OF FOUR (4) NEW 3315 RAYCAP BOXES C™/0 (2) WITHIN EXISTING EQUIPMENT SHELTER & TWO (2) AT EXISTING TOWER). 7. INSTALLATION OF THREE (3) NEW (6x12) 1-5/8" HOME RUN HYBRIFLEX (TYP. OF 1 PER SECTOR). THE SIZE OF THE EXISTING EQUIPMENT LEASE AREA AND FACILITY HEIGHT IS TO REMAIN UNCHANGED. '~· .._ __ • TOTAL NUMBER OF EXISTING ANTENNAS: 24 • TOTAL NUMBER OF ANTENNAS AFTER MOD: 24 • TOTAL NUMBER OF EXISTING RRUS: 6 • TOTAL NUMBER OF RRUS AFTER MOD: 12 CONSTRUCTION DATA: JURISDICTION: CONSTRUCTION TYPE: OCCUPANCY: RF DOCUMENT THESE PLANS DESIGNED PER AWS-3 DOCUMENT DATED: 8/9/17 CITY OF CARLSBAD V-B U/S-2 PROPRIETARY INFORMATION NOT FOR USE OR DISCLOSURE OUTSIDE VERIZON WIRELESS EXCEPT UNDER WRITTEN AGREEMENT '- . ~---------------------·-- • SITE NAME: 11 SQUIRES DAM 11 (AWS-3/850-L TE ADD) MTX: 44 3330 SUNNY CREEK ROAD CARLSBAD, CA 92010 VICINITY MAP THIS VICINITY MAP NOT TO SCALE PROJECT INFORMATION AS OF JANUARY 1, 2017 ALL WORK AND MATERIALS SHALL COMPLY WITH THE FOLLOWING: 2016 BUILDING STANDARDS ADMINISTRATIVE CODE PART 1, TITLE 24, C.C.R. 2016 CALIFORNIA BUILDING CODE (C.B.C.) PART 2, TITLE 24, C.C.R. (BASED ON THE 2015 INTERNATIONAL BUILDING CODE WITH 2016 CALIFORNIA AMENDMENTS) 2016 GALIFORNIA ELECTRICAL CODE (C.E.C.) PART 3, TITLE 24, C.C.R. (BASED ON THE 2011 NATIONAL ELECTRICAL CODE) 2016 CALIFORNIA MECHANICAL CODE (C.M.C.) PART 4, TITLE 24, C.C.R. (BASED ON THE 2015 UNIFORM MECHANICAL CODE WITH 2016 CALIFORNIA AMENDMENTS) 2016 CALIFORNIA PLUMBING CODE (C.P.C.) PART 5, TITLE 24, C.C.R. (BASED ON THE 2015 UNIFORM PLUMBING CODE) 2016 CALIFORNIA ENERGY CODE (PART 6, TITLE-24, CCR) 2016 CALIFORNIA FIRE CODE (C.F.C.) PART 9, TITLE 24, C.C.R. (BASED ON THE 2015 INTERNATIONAL FIRE CODE WITH 2016 CALIFORNIA AMENDMENTS) 2016 TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS AND ALL APPLICABLE CODES, LOCAL, CURRENT OSHA LAWS, T-24 ENERGY CONSERVATION, LISTS OF STANDARDS, AND DISABLED ACCESS REGULATIONS WHERE REQUIRED. PROJECT TEAM APPLICANT: VERIZON WIRELESS 15505 SAND CANYON AVE. BUILDING D, FIRST FLOOR IRVINE, CA. 92618 APPLICANT'S AGENT: PLANCOM, INC. 302 STATE PLACE ESCONDIDO, CALIFORNIA 92029 PH: (760) 420-4833 CONTACT: JILL CLEVELAND ARCHITECT: DERRA DESIGN, INC. 495 E. RINCON STREET, #204 CORONA, CA. 92879 951-268-1650 CONTACT: JEFF ROEBUCK OWNER: CITY OF CARLSBAD 405 OAK AVENUE CARLSBAD, CA 92008 PH: (760) 434-2836 CONTACT: REAL PROPERTY MANAGER CURTIS JACKSON APPROVALS APPROVED BY DATE INITIALS COMMENTS RF ENGINEER SITE DEV. SITE ACQ. PM COMMENTS: LEGAL DESCRIPTION A. P. N.: 169-500-05-00 & 169-230-02-00 CONSISTENCY DETERMINATION EXHIBIT FOR ORIGINAL PROJECT NOCL\f> OCI •O'i ~ /b. CDNo.2.0tS-0010 ',f.{ Date /0-3/-/8: Don Neu, City Planner RECOMMENDED BY~ ~ictn'\.. SHEET INDEX SHEET NUMBER DESCRIPTION T-1 T-2 A-1 A-2 A-3 A-4 A-5 A-6 A-7 TITLE SHEET GENERAL NOTES & SYMBOLS SITE PLAN EQUIPMENT LEASE AREA PLAN ANTENNA PLAN ELEVATIONS ELEVATIONS DETAILS DETAILS NOTES DATE-10-:5 c .Js 1 . THE MAXIMUM NUMBER OF PREVIOUSLY APPROVED DIRECTIONAL CELLULAR ANTENNAS IS TWENTY FOUR (24). 2. THE MAXIMUM NUMBER OF PREVIOUSLY APPROVED GPS ANTENNAS TO REMAIN INSTALLED IS ONE (1). 3. ALL ITEMS, WHETHER EXISTING OR NEW, WHICH ARE WITHIN THE VERIZON WIRELESS LEASE AREA ARE TO BE APPROVED. SPECIAL INSPECTIONS SPECIAL INSPECTION IS REQUIRED FOR THE WORK NONE (I) -cu 0 "O (I) ~ Q. Q. <( I--~ I-en => Q. w LL w 0.. s (I) [[ [[ z w 0 0 w 0 'c: 0 0 r--I (0 CX) C\J ~ 0) 0 s;j" 0) ~ N qi •-~ L a.. C 0 0 0 >,LL C U) aJ cu L ~ 0 ·-(0 LL C\J "O --0) C -cu \;) <( en OJO LD C _ 0 '5 (I) LD= C LD :::J ·-~ (]) 2: 2 0 (j) <( <Co ('.J z O--.0.-s (1)0 0:0 WO~N I-<( a:<( w CJ) w a: :::> w w <( w 0 01-o:o I z CJ) _JO 0-(j) 0 -I >-w b -:.e0z<C _J Woo zffi I- 25::J_j I-::J a: <(<((j)a: I-Z--o <( (j) w C00 z I-C0 -0 -C0 0 CJ) 3' ~ w > z w w "' ::, ::, C 0 V V .. ::, 0 "' "' C T-1 Job No. 1701N SPECIAL INSPECTION & STRUCTURAL OBSERVATION NOTES 1 . ITEMS REQUIRING SPECIAL INSPECTION AND/OR STRUCTURAL OBSERVATION FOR THIS PROJECT SHALL INCLUDE: A. NONE 2. A CERTIFICATE OF SATISFACTORY COMPLETION OF THE WORK REQUIRING SPECIAL INSPECTION MUST BE COMPLETED AND SUBMITTED TO THE INSPECTION SERVICES DIVISION. 3. AN APPLICATION TO PERFORM OFF -SITE FABRICATION MUST BE SUBMITTED TO THE INSPECTION SERVICES DIVISION FOR APPROVAL PRIOR TO FABRICATION. 4. A CERTIFICATE OF COMPLIANCE FOR OFF-SITE FABRICATION MUST BE COMPLETED AND SUBMITTED TO THE INSPECTION SERVICES DIVISION PRIOR TO ERECTION OF PREFABRICATED COMPONENTS. 5. THE SPECIAL INSPECTIONS IDENTIFIED ARE IN ADDITION TO THOSE REQUIRED BY SEC. 108 OF THE BUILDING CODE, AS AMENDED. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY A CITY INSPECTOR. 6. ALL OBSERVED DEFICIENCIES SHALL BE REPORTED IN WRITING TO THE OWNER'S REPRESENTATIVE, SPECIAL INSPECTOR, CONTRACTOR, & INSPECTION SERVICES. THE STRUCTURAL OBSERVER SHALL SUBMIT A WRITTEN STATEMENT TO INSPECTION SERVICES THAT THE SITE VISITS HAVE BEEN MADE AND IDENTIFYING ANY REPORTED DEFICIENCIES THAT HAVE NOT BEEN RESOLVED. THE STRUCTURE WILL NOT BE IN COMPLIANCE UNTIL THE DESIGNER HAS NOTIFIED INSPECTION SERVICES THAT ALL DEFICIENCIES ARE RESOLVED. 1 A SYMBOLS PROPERTY LINE DIMENSION LINE 1. CENTERLINE COLUMN LINE/ GRID LINE LETTERS IN ONE DIRECTION NUMBER IN THE OTHER DIRECTION SECTION CUT A SECTION LETTER A-2 --------SHEET WHERE SECTION IS DRAWN DETAIL REFERENCE @>---------DETAIL NUMBER \EV --------SHEET WHERE DETAIL IS DRAWN REVISION --------REVISION NUMBER WITH CLOUD AROUND REVISED AREA --------WORK POINT, DATUM, POINT, OR CONTROL POINT I XXX I -------ROOM NUMBER 0 0 --------WINDOW NUMBER --------DOOR NUMBER ---E) -------FLOOR PLAN NOTE (NUMBER) -----0 --------WALL TYPE (LETTER) CONSTRUCTION NOTES 1. HOURS OF WORK: CONTRACTOR TO OBSERVE BUSINESS HOURS 2. 3. OF 8 A.M. TO 6 P.M., M -F. ANY OTHER SPECIAL OR EXTENDED HOURS TO BE APPROVED BY OWNER REPRESENTATIVE. STAGING/LOADING AREA: ALL WORK MUST BE ARRANGED TO AVOID INTERFERING WITH EXISTING TRAFFIC (PEDESTRIAN & MOTOR) AND BUSINESS. ALL EQUIPMENT & MATERIALS MUST BE STORED IN NEW EQUIPMENT ROOM ONLY, UNLESS PRIOR AGREEMENT IS MADE BETWEEN VERIZON WIRELESS PROJECT MANAGER, OWNER AND CONTRACTOR. CONTRACTOR SHALL READ, UNDERSTAND, & ADHERE TO ALL NOTES ON THIS SHEET & ALL NOTES THROUGHOUT THIS SET OF CONSTRUCTION DOCUMENTS. ANY REQUIRED CHANGES AND/OR ADJUSTMENTS MUST BE MADE WITH THE PRIOR APPROVAL OF THE VERIZON WIRELESS PROJECT MANAGER AND THE ARCHITECT. 4. PROTECT ALL SURFACES & MATERIALS IN AND ADJACENT TO EQUIPMENT ROOM. ALSO PROTECT, PRESERVE AND CLEAN ALL AREAS; INCLUSIVE OF PATHS OF TRAVEL, IN AND BETWEEN ALL AREAS OF WORK. 5. CONTRACTOR TO MAKE APPOINTMENT WITH BUILDING OWNER REPRESENTATIVE PRIOR TO ANY X-RAY & CORE DRILLING THAT MAY AFFECT OTHER TENANTS. (]) -al 0 TI (]) > e Q. Q. <{ I--0 I-Cl) ::J Q. LL LL LL (]) 0 a: a: z LL ll 8 0 <{ -0 LL 0 f: 0 0 I'-I CD co (\J ~ Ol 0 'SJ" Ol ~ N ~ •-<{ '-I.. C 0 0 0 >,LL C -CO Cu ~ ,-0 ·-CD LL C\J TI _-OJ CO . al = <{ Cl) Ol 0 U) C -0 i5 Q) m=c :J ·-~ m 2: ~ (f) (f) 0 _J C) <( <(o 0 z o ___ o.-m wO a:o ~ s WO y:N >-<( CT:<( WO) (f) a: ::JW W<( 00 0 Of-a:o (f) z (/) _j O 0-w 0 -I >-I-I--:.0:>z<( 0 Wc},zlD z 0 ~s=:J~ =:J _J a: <(<((f)IT <( I-z ----o <( a: (f) w (")Q w z f-(") z 0 -(") w 0 (/) C) 15 I!:! c5 :z = "' ::,; ::,; 0 0 u u N ::,; C, "' "' 0 T-2 Job No. 1701N I I I I I I I I I I I I I I I I I I I I L __ -- SITE PLAN 0 f44 50' 100' 200' @l!i!!i!llllilll!ii!lll!lii!!'!iiil1 GRAPHC SCALE --------------------------- I \ I \ \ \\ (E) 5RAVEL ACCESS ROAD ----~~\ \ \ \ \ \ \ \ II NON-EXCLUSIVE PATH OF ACCESS \ \ ------ G NORTH SCALE: 1"-100'-0" --1 (\ -I> ". I.J vr -~ • .!... 111 C) C) ")II 71 " I \ ' \ \ I I \ I I \ ii ,; .~ \~ I I \ I I _\ 1---APPLEWOOD LANE \ \ (J) \ rn 10 \c lo \-\• \o \JJ rn ~ \ 51'-5" TO LEASE AR.EA PROPOSED VERIZON WIRELESS AREA OF IMPROVEMENT PROPOSED ANTENNA MODIFICATIONS AT (E) LEASE AREA -SEE EQUIPMENT LEASE AREA PLAN ON SHEET A-2 FOR MORE INFORMATION. (E) RESIDENTIAL (E) U/5 UTILITY ROUTE (SEE SHT. A-2 FOR. MORE INFOJ (E) RESIDENTIAL (E) VERIZON v-llR.ELESS EGUIPMENT SHELTER. (E) VERIZON v-llR.ELESS tl!::>5' Hl5H LATTICE TOV'IER. STRUC TUR.E, SEE ENLAR.5ED PLAN AT A2 FOR. MORE INFORMATION Q) ~ m 0 D Q) > 0 L Q. Q. <{ ~ ~ ~ Q. w lL Q) 0: 0: 0 t: = ~ 0 N •-Ii. 0 <( <Co 0 ,-..... O .-worro WO ~C\l a:<( w 0) :=>WW<( 01-[[Q (/)_JO 0- -I >- -: • C"') z <( Wchzm ~s :)~ <( <( Cf) {I z ._... 0 <( w C00 I-C') -C') (/) a= ~ ~ 5 ~ ~ "' ,. ,. 0 0 u u .. ,. 0 "' a, 0 w w z <( _J Q_ w I- Cf) A-1 Job No. 1701N (fJ 0. 0 I- :::i 3 w 0 0 0 r-- 1 (0 OJ C\I OJ 7 (J) ~ Cf) CJ z s <( {I 0 z 0 I- 0 :) {I I- Cf) z 0 0 ---------------------------"-----~ -------- (E) GRAVEL AC.C.ESS ROAD - Ac.C.E55 (E) e,• HleH C.HAIN LINK FENC.E w./ r x-x-x-x-STRANDED 6AR6ED V"llRE TOP x-x-x -x-x-x-x x X-x I -x-x-x- x x-x-x7 I X X I I X i PROPOSID VERIZON WRB.ESS j I xi AREA Of IMPROVEMENT x / PROPOSED ANTENNA MODIFICATIONS AT ~--_J PLAN ON SHEET A-3 FOR MORE INFORMATION. X x/ EXISTING STEB. LATTICE TOWER -SEE ANTENNA x . I X I X I X I X I I ( X X (E) AC.C.ESS 6ATE ------ ~-----(E) OVERHEAD C.A6LE TRAY ~/1 ~/ I l I l I l I l I I l (E) VERIZON WIRELESS EQUIPMENT SHELTER ~/ I X I X I X I X I X X --- ! X l--x--x--x--x--x--x '---VERIZON V"llRELESS TO INSTALL (N) 5515 RAYC.AP AT INTERIOR OF (E) SHELTER ADJAC.ENT TO (E) RAYC.AP I X I X I (TYP. OF .2) X x----x--x'---x--x--x--x--x--x--x--x___j (E) 6AC.KUP eENERATOR ON DIESEL SU6-SASE TANK V"llTHIN A(;,' Hl6H C.HAIN LINK FENC.E ENC.LOSURE TO REMAIN UNC.HANeED '-----------(E) VERIZON V"llRELE55 t155' H16H STEEL LATTIC.E TOHER STRUC.TURE, SEE ENLAReED PLAN AT SHT. A-5 FOR MORE INFORMATION I I I I I I I I I I I I I I I ' I /! I 't:; f ll". Ii I ii} ''-I ' I I • I I I I I P I I p I ' ' I I ' I I r I I I I I I I f I I I ' I f I I I I I I I '-----------(E) C.HAIN LINK ROLLIN6 eATE w./ STRANDED SAR6ED V"llRE TOP I ' ·----' --------------------J -------------~ (E) PROPERTY-L-IN_E_ ------------------ ENLARGED SITE/ LEASE AREA PLAN 0 4' 8' 16' F zzmw f' e · rn '"1 GRAPHC SCALE @ NORTH SCALE: 1/8"al'--O" p p (E) RESIDENTS - i (E) SIDEY'<ALK (E) PRIVATE DRIVEY'<AY (E) RESIDENTIAL \ BUILDING --1P--P--P'--P--,e--P--1P--P--1P--P--p1 __ \ P-,p-P (E) ELEC. TRIC.AL P.O.C.. (E) RESIDENTIAL BUILDING . --,P--P---,,.-:J ----(E) U/e ELEC. TRIC.AL UTILITY TRENc.H (E) SD64 E ---~ TRANSFORMER (IIDIO411-85.2) (E) RESIDENTS ,~ l___------.-------\ (E) PRIVATE DRIVEV"lAY I \ -----------------· --------·----- Q) -al 0 D Q) > e Q. Q. <( I--~ I-(fJ ::i Q. w LL w I]_ Q Q) 0: 0: z w 0 <( 0 w w 0 t: 0 0 I'- ' (D (lJ N ~ 0l <;j- 0 0l ~ N Q) •-> <( '-I.. C 0 0 0 >,LL C -00 CG ~ ,- 0 U::: ~ "(J_-0) C [) . al = <( (fJ 0) 0 LO C -0 i5 Q) LO= C ::J ·-~ m 2: z <( ~ _J Cl) 0 Q_ ('.) <( <Co <( z O ,_0,-w 5 (1)O0:0 0: wo~N <( <( a:<( w (J) w 0: :)WW<( Cl) 0 Of-o:o <( z w (J) _JO 0-_J 0 -I >--f---:.C0z<C w Wchzm f-0 ~5::J~ Cl) ::J 0 0: <(<((f)O: f--Z---o<C w Cl) w C00 ('.) z f-C0 a: 0 -C0 <( 0 (J) _J z w A-2 Job No. 1701N (E) VERIZON J,,JIR.ELESS 5515 ---~ R.AYCAP AT TOJ,,JER. FACE TO 6E RELOCATED (E) 48"H. PR.EVIOUSL Y APPROVED SPARE PANEL ANTENNA TO REMAIN (TYP. OF 12) (E) CA6LE LADDER. UP TOJ,,JER. --~ (E) <'16"H. PR.EVIOUSL Y APPROVED -----......_ (TYP. OF 2 AT 6ETA SECTOR.) (E) PR.EVIOUSL Y APPROVED RR.US TO ----.._ REMAIN (TYP. OF 2 AT 6ETA SECTOR.) (E) VERIZON J,,JIR.ELESS 1064 ---- R.AYCAP TO 6E REMOVED 4 t:;.;_...~- R.EPLACED Jl',IITH (E) 5515 ""-~1111--j; "~..,_;"I R.AYCAP AT TOJ,,JER. FACE (E) 48"H. PR.EVIOUSL Y APPROVED -------~- PANEL ANTENNA TO 6E '--.J""fs,; RELOCATED TO POSITION I (E) <'16"H. PR.EVIOUSL Y APPROVED-------- PANEL ANTENNA TO 6E RELOCATED TO POSITION 2 (E) 155' STEEL LATTICE TOJ,,JER. ___ __,- (E) <'16"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO 6E REMOVED/REPLACED (TYP. OF 2 AT ALPHA SECTOR.) (E) PR.EVIOUSL Y APPROVED RR.US ----~ TO REMAIN (TYP. OF 2 AT ALPHA SECTOR.) EXSITING ANTENNA PLAN 0 1' 3' 6' j, 4 r: ffig;ia a '1 GRAPHIC SCALE ------------------ ,,-----(E) <'16"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO 6E RELOCATED TO POSITION 2 (E) 48"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO 6E RELOCATED TO POSITION I TYP. MM DISH TO REMAIN _.,---(E) 1064 R.AYCAP TO 6E REMOVED AND REPLACED -17~,~"'-J-+------(E) "!6"H. PREVIOUSLY APPROVED PANEL "180° ALPHA AZIMUTH ANTENNA TO 6E R.EMOVED/R.EPLAC-ED (TYP. OF 2 AT <SAMMA SECTOR.) ----(E) PR.EVIOUSL Y APPROVED RR.US TO REMAIN (TYP. OF 2 AT <SAMMA SECTOR.) ___.--(E) 1064 R.AYCAP TO 6E REMOVED AND REPLACED (E) <'16"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO 6E RELOCATED TO POSITION 2 ..____ (E) 48"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO RELOCATED TO POSITION I 0 NORTH SCALE: 3/8"=f-0° PROPOSED ANTENNA SCHEDULE SECTOR AZIM- UTH ALPHA 1 180" ALPHA 2 170· ALPHA 3 170" ALPHA 4 170" BETA 1 300" BETA 2 300" BETA 3 300" BETA 4 300" GAMMA 1 so· GAMMA 2 so· GAMMA 3 so· GAMMA 4 so· TOTAL: (E) 48"H. PR.EVIOIJSL Y APPROVED SPARE -------~ PANEL ANTENNA TO REMAIN (TYP. OF 12) @ (E) PR.EVIOUSL Y APPROVED "16" PANEL ANTENNAS TO 6E INSTALLED ON NEJ,,J DUAL MOUNT 6R.ACKET (TYP. OF 2 AT 6ETA SECTOR.) CABLE RUN ±175' ±175' ± 175' ±175' ±175' ±175' ± 175' ± 175' ±175' ± 175' ± 175' ±175' (E) PR.EVIOUSL Y APPROVED RR.US TO --~ REMAIN (TYP. OF 2 AT 6ETA SECTOR.) 700-LTE/ 850-L TE/ AWS/AWS-3 @ VERIZON J,,JIR.ELE55 <5.C. TO INSTALL (5) NEJ,,J (6Xl2) 1-5/8" HOMER.UN HY6R.IFLEX AT (E) __ -, CA6LE LADDER. UP TOJ,,JER. -~--7/ (E) <J6"H. PR.EVIOUSL Y APPROVED -----¾':__--I PANEL ANTENNA TO REMAIN AT 6ETA SECTOR. ~ (N) VERIZON J,,JIR.ELESS RR.US ~ (65) COM6O UNIT FOR. 85O-L TE 4 (615) COM6O UNIT FOR. SPARE 1OO-LTE PIPE MTD. 4 STACKED 6EHIND (E) ANTENNA ON (E) MOUNT AT 6ETA SECTOR. / (E) 48"H. PR.EVIOIJSL Y APPR.OVEc,-----/' PANEL ANTENNA TO REMAIN AT 6ETA SECTOR. (E) 155' STEEL LATTICE TOWER. (E) PR.EVIOUSL Y APPROVED RR.US --- TO REMAIN (TYP. OF 2 AT ALPHA SECTOR.) (E) PR.EVIOIJSL Y APPROVED <16" PANEL (,"i ANTENNAS TO 6E INSTALLED ON NEJ,,J \fy DUAL MOUNT 6R.Ac.KET (TYP. OF 2 AT ALPHA SEC TOR.) 700-LTE/ 850-LTE/ AWS/AWS-3 700-L TE/ 850-LTE/ PCS-LTE CENTER LINE 147'-0" 147• -o" 147'-Q" 147'-Q" 147'-Q" 14 7' -0" 147'-Q" 147'-0" 147'-Q" 147'-o" 147'-0" 147'-Q" CABLE TYPE/ SIZE (2) 7/8"/fJ ( 1 ) HYBRIFLEX (2) 7/8"/fJ (1) HYBRIFLEX (2) 7 /8"/fJ (1) HYBRIFLEX (6) 7 /8"/fJ (3) 1-5/8"/fJ HYBRIFLEX SPARE PROPOSED ANTENNA PLAN 0 1' 3' 6' F !lit @& 't ril ifl1~ *'4 GRAPHIC SCALE ---~ --------- ANTENNA RRUS/RA YCAP TYPE 48"H. SPARE ANTENNA 96"H. PANEL ANTENNA (1) RRUS (B13) COMBO UNIT FOR 700-LTE (1) RRUS (BS) COMBO UNIT FOR 850-LTE SBNHH-1 D65C (1) RRUS (B2) FOR PCS-LTE NEW (1) 3315 RAYCAP SBNHH-1065C (1) RRUS (B66) AWS/AWS-3 48"H. SPARE ANTENNA 96"H. PANEL ANTENNA ( 1) RRUS (B1 3) COMBO UNIT FOR 700-LTE (1) RRUS (B5) COMBO UNIT FOR 850-LTE SBNHH-1 D65C (1) RRUS (B2) FOR PCS-LTE EXIST (1) 3315 RAYCAP SBNHH-1 D65C (1) RRUS (B66) AWS/AWS-3 48"H. SPARE ANTENNA 96"H. PANEL ANTENNA (1) RRUS (B13) COMBO UNIT FOR 700-LTE (1) RRUS (B5) COMBO UNIT FOR 850-LTE SBNHH-1 D65C (1) RRUS (B2) FOR PCS-LTE NEW (1) 3315 RAYCAP SBNHH-1 D65C (1) RRUS (B66) AWS/AWS-3 (3) EXIST. RRUS (B2) (PCS-LTE) (6) SBNHH-1065C (3) EXIST. RRUS (B66) (AWS/AWS-3) (3) 72"H. PNL. ANTENNAS (3) (N) RRUS (B5) COMBO UNIT (850-LTE) (3) SPARE ANTENNAS (3) (N) RRUS (B13) COMBO UNIT (700-LTE) SPARE 180° ALPHA AZIMUTH (3) 3315 RAYCAPS (E) 48"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO REMAIN AT <SAMMA SEC TOR. (N) VERIZON J,,JIR.ELE55 RR.US (65) COM60 UNIT FOR. 85O-L TE 4 (615) COM60 UNIT FOR. 1OO-L TE PIPE MTD. 4 STACKED 6EHIND (E) ANTENNA ON (E) MOUNT AT <SAMMA SECTOR.c;-....., r::eJ _.,,..--(E) <J6"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO REMAIN AT <SAMMA SEC TOR. TYP. MM DISH TO REMAIN __c..--VER.IZON J,,JIR.ELESS TO REMOVE 4 REPLACE (E) 1064 R.AYCAP ""/W (N) 5515 R.AYCAP (TYP. OF 2) r::eJ -----(E) PR.EVIOUSL Y APPROVED RR.US TO REMAIN (TYP. OF 2 AT <SAMMA SECTOR.) 700-LTE/ 850-LTE/ PCS-LTE (E) PREVIOUSLY APPROVED <'16" PANEL ANTENNAS TO 6E INSTALLED ON NEJ,,J DUAL MOUNT 6R.ACKET@ (TYP. OF 2 AT <SAMMA SECTOR.) A~S 700-LTE/ 850-LTE/ AWS/AWS-3 ,,--(N) VERIZON Jl',IIR.ELESS RR.US (65) COM60 UNIT FOR. 85O-L TE 4 (615) COM60 UNIT FOR. 1OO-L TE PIPE MTD. 4 STACKED 6EHIND (E) ANTENNA@(E) MOUNT AT ALPHA SECTOR. 4 A-7 (E) 48"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO REMAIN AT ALPHA SEC TOR. --.. __ (E) <J6"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO REMAIN AT ALPHA SEC TOR. 0 NORTH SCALE: 3/8"-f-0" (I) -(ll 0 D (I) > 0 ~ Q. Q. <( -0 Q. w LL (I) c6 0: a: 0 <( f: ~ 0 N •-Ii. 0 <( <Co 0 .-.. Or- (1)0 o:o WO ~C\J a:<( w 0) :=)WW<( I-z - QI-[[Q (/) __J o o~ -I >--: • C") z <( Wchzm ~s=:J~ <(<((f)O: Z ..__.. o <( w (")Q I-(") -(") (I) 8 !:l en w w z <( _J 0.. <( z z w f-z <( A-3 Job No. 1701-l (j) Q_ 0 I-:::i Q w w 0 0 0 l'-1 (D co N m -st" 0- CJ) CJ z 5 <( 0: 0 z 0 f-0 =:J 0: f- CJ) z 0 0 ~ ~ z z z z w w I-I-z z O! 4'. 4'. w ...I ...I :s:: 8 Ill Ill z z 4'. 4'. Ill ll.. ll.. () Ill :!l I-Ill I-w Ill 4'. ...I ...I ...I w Ill ...I O! O! :s:: :s:: Ill Ill z z I-Ill a a ~ N N Ill O! O! ~ Ill Ill IL > > a l ~ ll.. t 8 ... ... 8 ~ ~ Ill !!:! ~ C) IL IL a a I ifl 0.: Ii II\ a I- I-() a Q I-4'. • O! a a I -I-"' a I r-v @ (E) VERIZON Y'IIRELESS 5515 RAYC.AP RELOC.ATED FROM TOY'IER FAC.E SOUTH ELEV A TION 0 4' 8' 16' F '6 ~ ii' jj r f ,_, em I GRAPHC SCALE ---------------(E) Y'IHIP ANTENNA TO REMAIN (TYPJ (E) 4E,"H. PREVIOUSLY APPROVED SPARE PANEL ANTENNA TO REMAIN (TYP. OF 12) (E) Y'IHIP ANTENNA TO REMAIN (TYP.) ----~ (E) 4b"H. PREVIOUSLY APPROVED SPARE-~ PANEL ANTENNA TO REMAIN (TYP. OF 12) (E) PREVIOUSLY APPROVED RRUS TO REMAIN (TYP. OF 2 AT <SAMMA SEC.TOR) __.-----(E) "!b"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT <SAMMA SEC.TOR ~-(N) VERIZON Y'IIRELESS RRUS (65) C.OM6O UNIT FOR 7-----------------------------f';"'1\lii=.!!=+:'ili=:/;r,::i;i===n:7"'7 b5O-L TE 4 (615) C.OM6O UNIT FOR 10O-L TE PIPE MTD. 4 STAC.KED BEHIND (E) ANTENNA ON (E@ ----(N) VERIZON Y'IIRELESS RRUS (65) C.OM60 UNIT FOR b5O-L TE 4 (615) C.OMOO UNIT FOR 1OO-L TE PIPE MTD. 4 STAC.KE:D@ MOUNT AT ALPHA SEC. TOR 4 r--...___...___..._____ A-7 I (E) 4b"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT ALPHA SEC.TOR ----(E) "!b"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT ALPHA SEC.TOR (E) PREVIOUSLY APPROVED RRUS TO REMAIN (TYP. OF 2 AT ALPHA SEC.TOR) (E) PREVIOUSLY APPROVED 'lb" PANEL ANTENNAS TO 6E INSTALLED ON NEY'! DUAL MOUNT 6RAC.KET (TYP. OF 2 AT ALPHA SEC.TOR)~ ----TYP. MM DISH TO REMAIN ~ 1----------(E) 155' STEEL LATTIC.E TOY'IER SCALE: 1/8" • 1'-!l" (E) C.A6LE 6RID5E TO REMAIN UNC.HAN<SED (E) BAC.KUP <SENERA TOR ON DIESEL SU6 BASE TANK TO REMAIN UNC.HAN<SED (E:) VERIZON Y'IIRE:LE:SS E:GUIPMENT SHELTER (E) C.HAIN LINK FENc.E ,..; STRANDED 6AR6E:D Y'IIRE TO REMAIN Ill 4'. z z w I- O! z 4'. w :s:: ...I w a z I-4'. Ill ll.. () Ill I-Ill I-Ill 4'. ...I ...I Ill O! ...I :s:: Ill Ill I-z Ill a ~ N Ill O! ~ Ill IL > a l ll.. a I-... a ~ Ill I-~ a I IL a \'() 0.: II\ a I- 8 a I - "' (E) 4b"H. PRE:VIOUSL Y APPROVED PANEL------JiL~ ANTENNA TO REMAIN AT ALPHA SEC.TOR -'I.-----------IJ-W Ill 4'. z z Ill I-z 4'. ...I Ill z 4'. ll.. :!l w ...I Ill O! :s:: z a N O! Ill > g .. ~ w ~ IL a Ii I- () Q 4'. O! a I- • a I r-v @(N) VERIZON Y'IIRE:LESS RRUS (65) C.OM60 UNIT FOR b5O-L TE 4 (615) C.OMOO UNIT FOR 1OO-L TE PIPE MTD. 4 STAC.KE:D BEHIND (E) ANTENNA ON (E) MOUNT AT ALPHA SEC.TOR @(E) PREVIOUSLY APPROVED 'lb" PANEL ANTENNAS TO 6E INSTALLED ON NEY'! DUAL MOUNT 6RAC.KET (TYP. OF 2 AT ALPHA SEC.TOR) (E) "!b"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT ALPHA SEC.TOR @VERIZON Y'IIRELESS TO REMOVE 4 REPLAC.E (E) 1Ob4 RAYC.AP ,..; (N) 5515 RAYC.AP (TYP. OF 2) 0 BEHIND (E) ANTENNA ON (E) MOUNT AT <SAMMA SEC.TOR 4 I I ,__ __________ (E) 4b"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT <SAMMA SEC.TOR ~---(E) PREVIOUSLY APPROVED 'lb" PANEL ANTENNAS TO 6E: INSTALLED ON NEY'! DUAL MOUNT 6RAC.KET (TYP. OF 2 AT <SAMMA SEC.TOR)~ ~ -t++------------VERIZON Y'IIRE:LE:SS 5.C.. TO INSTALL (5) NEY'! (bXl2) 1-5/b" HOMERUN HY6RIFLEX AT (E) C.A6LE LADDER UP TOY'IER (10\ I I I I I I I I I I I I I I ! I 'C!} (E) 155' STEEL LATTICE: TOY'IER (E) VERIZON 1-"llRELESS EGUIPMENT SHELTER (E) C.HAIN LINK FENC.E ,..; STRANDED 6AR6E:D Y'IIRE TO REMAIN A-7 EAST ELEV A TION SCALE: 1/8" -1'-0" 0 4' 8' 16' iii{; ' 1/ill t 1 d j GRAPHIC SCALE ----------------------- CJ) -ro 0 D (j) > 2 0. 0. < -u I-0. w LL (j) 0 ([ ([ z 0 < - 'c: = L 0 N •-a.. 0 <( <l'.:o 0--.0..--worro w O ~C\I 0:<(WO) ::i w w <{ OI-ITO (/)_JO •- -I >--: • Cl') z <{ Wch zm Ls ::J~ <C <C en rr z --0 <{ w 0')0 I-(Y) -(Y) (/) 8 ~ "' w w en z 0 I-<{ > w _J w (f) 0.. 0 1--::i Q w w 0 0 0 r--1 (D CX) (\J w ~ en C; z s <{ [( 0 z 0 I- 0 ::J [( I-en z 0 0 A-4 Job No. 1701N II\ II\ <( <( z z z z w w I-I-z z Ill <( <( w ...1 3: ...1 a w w z z I-<( <( w 0.. 0.. \) $ II\ I-II\ I-w w <( ...1 ...1 ...1 w w Ill Ill ...1 3: 3: w w z I-z II\ a 0 ~ N N w Ill Ill ~ w w IL > > a 0.. ~ ~ a .. I-.. 0 ~ ~ w w I-~ ~ Q IL IL 0 0 I 11) 0..: Ii "' a I- I-\) a C\ I-<( • Ill a 0 I -I-"' • 0 I .... ~ (E) PREVIOUSLY APPROVED RRUS TO ------ REMAIN (TYP. OF :2 AT 5AMMA SECTOR) W VERIZON WIRELESS TO REMOVE 4 REPLACE (E) -~ '0:!J IOE>4 RAYCAP .,..; (N) 5515 RAYCAP (TYP. OF :2) @(E) PREVIOUSLY APPROVED "'IE>" PANEL ANTENNAS TO SE INSTALLED ON NEW DUAL MOUNT BRACKET (TYP. OF :2 AT 5AMMA SEC TOR) (N) VERIZON WIRELESS RRUS (BS) COMBO UNIT FOR 8e.so-LTE 4 (615) COMBO UNIT FOR "1OO-LTE PIPE '0:!}MTD. 4 STACKED BEHIND (E) ANTENNA ON (E) MOUNT AT ALPHA SECTOR W (E) VERIZON WIRELESS 5515 RAYCAP -~ "0.:!J RELOCATED FROM TOWER BELOW (E) "'IE>"H. PREVIOUSLY APPROVED PANEL-~ ANTENNA TO REMAIN AT 5AMMA SECTOR (E) 4e>"H. PREVIOUSLY APPROVED PANEL --~ ANTENNA TO REMAIN AT 5AMMA SECTOR I I @ VERIZON WIRELESS 5.C,. TO INSTALL (5)-------------'-A---"-1 j NEW (E>Xl:2) 1-5/e>" HOMERUN HYSRIFLEX AT (E) CABLE LADDER UP TOWER (E) CABLE SRID5E TO REMAIN UNC,HAN5ED (E) BACKUP 5ENERATOR ON -- DIESEL SUS SASE TANK TO REMAIN UNCHAN5ED (E) VERIZON WIRELESS ---~ EQUIPMENT SHELTER (E) CHAIN LINK FENCE .,..; STRANDED SAR.BED WIRE TO REMAIN NORTH ELEV A TION 0 4' 8' 16' r-b e ~!b@ *I GRAPHC SCALE SCALE: 1/8" -1' -0" I I I I I I I I I I I I I I I I I i I I I I I .---(E) WHIP ANTENNA TO REMAIN (TYP.) (E) 4e>"H. PR.EVIOUSL Y APPROVED SPARE PANEL ANTENNA TO REMAIN (TYP. OF 1:2) >---(E) 4e>"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT SETA SECTOR. (E) "'IE>"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT SETA SECTOR (E) PR.EVIOUSL Y APPROVED "'IE," PANEL ANTENNA TO SE INSTALLED ON NEW DUAL MOUNT BRACKET (TYP. OF :2 AT SETA SEC TOR.)~ ~ TYP. M/W DISH TO REMAIN (E) 155' STEEL LATTICE TOWER aw . \) I-z • w QIL _, ~ d).!!:J Ill w 3: a I- w \) ~ I-<( ...1 ...1 w w I- II\ ~ w ~ IL 0 0.. a I- ~ Q I ifl "' ~ ~ z z z z w w I-I-z z <( <( ...1 ...1 w w z z <( <( 0.. 0.. $ $ w w ..J ...1 w w Ill Ill 3: 3: z z 0 0 N N Ill Ill w w > > z z ~ ~ .. .. ~ ~ w w ~ ~ IL IL 0 a 0..: Ii 0 I- I-\) a C\ I-<( Ill 0 0 I . I-"' 0 I .... ~ --------·---- (E) PREVIOUSLY APPROVED RRUS TO ------.___ REMAIN (TYP. OF :2 AT 5AMMA SECTOR) @ (E) PREVIOUSLY APPROVED "'IE," PANEL ANTENNA TO SE INSTALLED ON NEW DUAL MOUNT BRACKET (TYP. OF :2 AT SET A SEC. TOR.) (E) VERIZON WIRELESS 5515 R.AYCAP _ _,. R.ELOC.ATED FR.OM TOWER. FAC.E @ VERIZON WIRELESS 5.C. TO INSTALL (5) NEW (E>Xl:2) 1-5/e>" HOMERUN HYSRIFLEX AT (E) CABLE LADDER UP TOWER (E) VERIZON WIRELESS EGlUIPMENT---._ SHELTER (E) CHAIN LINK FENCE.,..; STRANDED-- SAR.BED WIRE TO REMAIN WEST ELEV A TION 0 4' 8' 16' f4 Gtttd @9 GRAPHIC SCALE SCALE: 1/8" -1'-0" (E) WHIP ANTENNA TO REMAIN (TYP.) (E) 4e>"H. PREVIOUSLY APPROVED SPARE PANEL ANTENNA TO REMAIN (TYP. OF I :2) (E) PREVIOUSLY APPROVED RRUS TO REMAIN (TYP. OF :2 AT ALPHA SECTOR.) ------(E) PREVIOUSLY APPROVED "'IE>" PANEL ANTENNA TO SE INSTALLED ON NEW DUAL MOUNT SRAC.KET ~ (TYP. OF 2 AT ALPHA SEC.TOR)~ VERIZON WIRELESS TO REMOVE '@ REPLACE (E) IOE>4 RAYC.AP .,..; (N) A~7 5515 R.AYC,AP (TYP. OF :2) (E) 4e>"H. PREVIOUSLY APPROVED PANEL ANTENNA TO REMAIN AT SETA SEC.TOR (N) VERIZON WIRELESS RRUS (BS) COMBO UNIT FOR e,so-L TE 4 (615) C,OMBO UNIT FOR "1OO-LTE PIPE MTD. 4 STACKED BEHIND (E) ANTENNA ON (E) MOUNT AT SETA SEC TOR G"'-., '0:!} (E) "'IE>"H. PR.EVIOUSL Y APPROVED PANEL ANTENNA TO REMAIN AT SETA SEC.TOR TYP. M/W DISH TO REMAIN (E) 155' STEEL LATTICE TOWER 0 llJ ·\) I-z ' llJ () IL _, ~ d) -!!:! Q) -(1l 0 D Q) 6 L Q. Q. <{ -~ Q. w lL Q) [[ [[ 0 <{ 'c: 2 0 N •-I.. I-z - 0 <( <Co 0 ,,-.._0.,- (f)OITo w O ~(\J a:<( w (J) :::> w w <( QI-ITO (/)_JO 0- -I >--:.C0z<C Wchzm 23; :J~ <( <( Cf) ([ z ---o <( w C00 I-C') -C') (f) w w Cf) z 0 ~ w _J w /~c5 ,-,:c /-~-?):: (f) 0.. 0 I- ::J 8 w 0 0 0 f'- 1 CD co (\J 0) '<I' 0) ~ Cf) CJ z s <( ([ 0 z 0 I- 0 :J ([ I-Cf) z 0 0 .. ,.~_...,,,...N\ G ,. -~-' '.l-.: '//VY,~ ~ ':,.;--.,,:,,, 1~/.;y '?,\l)i\ •... J'~ t~·.~-~ 11_ NO. C-34940 j·k; \':> R0 N 6130/19 ~:/ '. 1.--~ -1 .. ;);" _ OCT ~~<018 U;'.:: cf---:)\·· - A-5 Job No. 1701N .. / DUAL MOUNTING BRACKET COMMSC~PE® Instruction Sheet 639846 Revision D, August 2017 Side-By-Side Mounting Kit BSAMNT-SBS-1-2 GENERAL INFORMATION · The BSAMNT-SBS-1-2 Mounting Kit allows mounting two 300mm wide onte~nm with 2 mount points side by side. Please visil the product page of this_ mounting kit on the cornmscope webpoge for a list of anlennos which ore supported by this bracket. Mounting systems for cylindrical pipe imtollo1ions (60-11 Sm pipe diameter) for heavy duty applications_ PRE-INSTALLATION INSTRUCTIONS · Thoroughly read the directions included in this bulletin before starting to assemble parts. · Carefully remove all parts from the shipping boxes. Examine the antenna and hardware to ensure tho1 all ports are enclosed and lho1 there is no physical damage. Check 1o ensure that t/1e antenna feed connector motes with the jumper coble. · Verify rho! frequency range shown on the label on the bock of the antenna matches the frequency range of the station equipment. · Posifion the antennas so that the drain holes ore directed down toward ihe ground. GENERAL INFORMATION BSAMNT-SBS-1-2 kit is used to mount two antennas side-by-side. Kit's details as Figure 2. · The BSAMNT-SBS-1-2 kit co~tains two 627281 mounting brackets and one BSAMNT-4 downTilf kit. Rel er to Bulletin 639849-1, included with the 8S AMNT-4 ki~ for proper antenna installation. 627281 MOUNTING BRACKET INSTALLATION Do not remove, loosen. or adjust the antenna mounting plate(s). Using the 627281 mounting brackets and hardware provided, assemble two antennas side-by-side. Tighten the Ml 0 nut with torque 37 N.m. Refer to Figures 1 and 3. { continued on page 2) www.commscope.com © 2017 CommScope, Inc. All rights reserved, Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more Information. All trademarks identified by® or w are registered trademarks or trademarks, respectively, of CommScope, Inc. 639846 D (08117) Instruction Sheet (Continued from page !) (€ Page1of4 639846 ------------------------·7 Attach a 627281 mounting bracket on the top and 1he botiom antenna plates respectively. T Op 62728 l Bracke1 ' I j-,: ..-~1 ,, I i LJ L__J •I :JJ ! ! If 81 ~ ca\11 q .... -... - Bottom 627281 Bracket l ______________ 2_A_n_t_e_n_n_a_s_M_o_u_n_t_e_d_B_y_6_2_7_2_8_1_B_,a_c_k_e_t ____________ ~ Figure I. Methods for Antenna Assembly Using 627281 Mounting Brackets. (continued on page 3) www.commscope-.com © 2017 CommScope, Inc_ All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information All trademarks Identified by® or"™ are registered trademarks or trademarks, respectively. of CommScope, Inc. 639846 D (08117) (€ Page 2 of 4 Instruction Sheet 639846 (Continued from page 2) BSAMNT-SBS-I-2 _J Figure 2. BSAMNT-SBS-l-2 kit. TORQUE : M lO "" 37 N.m ANTENNA MOUNTING PLATE 1·MOUNTING BRACKET I MOUNTING BRACKETl ANTENNA MOUNTING PLATE -1 i [[lOLOCK WASHE SCREW MlO 1 I lrlOHEXHDNUT ' SCREW M 107 ----------i i '. ·.· MlOHEXHDNUT7 I i._ l,· FI~~-c1ib! t i ~ Li _----.Jd-ful,u~-- --r Figure 3. Attaching 627281 Mounting Bracket to Antenna. (continued on page 4) www.commscope.com © 2017 CommScope, Jnc. All rights reserved. Visit our website at www.commscope_oom or contact your local CommScope representative or BustnessPartner for more information. All trademar};;s identified by® or ™ are registered trademarks or trademarks, respectively, of CommScope, lnc. 639646 D (08117) Instruction Sheet (Continued from page 3) Refer ro Bufletin 639849-1 fo: instructions on using the pipe mount and downlilt bracket[s) io oitoch the slde-by-side ontenna assembly lo lhe mm!. (3ulletin 639849-1 is included w:th the BSAMNT-4 kit.) 1·Antenna Mounting P!ote. Do {]Of remove, loosen. or adjust the antenna mounting plote(s.). \ \ \ ' --.i-;_·- \ \ \ \ ~-Pipe Mount Brackets ' \\ \ ' \ I \ ~ I ' . ', I \ / ; \ \ \ .·< / '-, I I ' ', -. ..:._ ' -' \ \ ''-----627281-1 Brackets \_Down1ilt Brac;.:.ets \ \ \ \ \,, I __ CE Page 3 of 4 639846 'i't ii ' 1,\ " !i ,, " ',I ,, I' ,\ ,, ,, i • \', \: ,, \, 1, I I ' ' ' ' I I ' ' ' I I I '1 \ li, F"i ' r,I !ID \ ~', c---4_ I le, '1 [sl I Q\ ' Figure 4. Antenna Assembly Attached to Mast Using BSAMNT-SBS-!-2 Mounting Kits SAFfT'Y NQTJCE The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. CommScope instollotion instructions are written for such insta!lotion personnel. Antenna systems should be inspected once o year by qualified personnel to verify proper installation. maintenance, and condition of equipment. CommScope disclaims ony liability or responsibility for the results of improper or unsafe installat1on practices. It is recommended that transmit power be turned off when the field installation is performed. Follow all applicable safety precautions a~ shown on thi,-page. www.commscope.com © 2017 CommScope, Inc. All rights reserved. Do not lesta.l neo, po~, r.,~,. Pa"""' lo,c-,. •alcpaone lne~ and guy w,e, Jc,ok 1h;o «>•n• A!5um~cnywno,oc ine ~~n leclmcuie you Do '"'' 01,t•l on o wel o, ,,.,,,xiy d•y oc wl1en igl,"1ir.g a< ttiur.dL• ~ h !he at~O-Do nut'"" metol lc,dd~, Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademsrks identified by® or 1"' are registered trademarks or trademarks, respec~vely, of CommScope, Inc. 639846 D (08/17) WM1 shoe< wnt, rtJot,e, role< ""d l_>=h. WL"G[ pm~c'"• dcll,;ig 1nd1Jd1ng <1 l=g-,l~e.-,,d ,'1ir1 ar,d rubb~, gl:,,io, (€ Page4ol4 Q) -m 0 "'CJ Q) > e Q_ Q_ <{ 1---0 1--(J) :::J Q_ o6 w LL w D.. Q Q) a: a: z w 0 <{ -0 w w 0 'c: 0 0 r-- I co CX) (\J ~ 0) 0 st 0) ~ N Q) •-~ ,__ Ii. C 0 0 0 >, LL C ~ 00 co ~ ,- 0 u:: ~ u -"0) C Cl . (1l = <{ CJ) 0) 0 lO C " ou Q) lO= C lO ::, ·2: ~ [[)_ = 2 0 en en CJ <( <(o _J z 0 ____ o .--~ -- wO [[o s w O y:: C\J w <( a:<( w m 0 [[ ::)WW<( _J 0 01---[[0 <( z (/)_JO 0-[[ 0 -I )-:) f---: . C') z <( f-0 Wch zm 0 23: :)~ w :) f-[[ <(<(en[[ I f-Z ---a<( en w (Y)O 0 z I-(Y) [[ 0 -(Y) <( 0 (I) A-6 SCALE: NONE 1 Job No. 1701N HYBRIFI.JEX™ RRH Hybrid Feeder Cabling Solution . RFS'·iinique HYBRIFLEX RRH hybrid feeder cabling solution was developed to reduce installation complexity and costs at cellular sites. HYBRIFLEX allows mobile operators deploying an RRH architecture to standardize the RRH installation process and eliminate the need for and cost of cable grounding. HYBRIFLEX combines optka! fiber (multi-mode or single-mode) and power in a single corrugated cable. Specifications Characteristics ' Co!ISTI1.lction Norms and standards applied Power cable -Used to feed the RRH or Remote Radio Unit (RRU) i Conductor: Flexible tinned copper wires Isolation: Flame-retardant PVC JaCket -NBR NM 247-3: Isolated cables with PVC for nomima:I voltages up to 451JJ750V, Part 3; isolated conductor:;forfixed installation:; (IEC 60227--3 MOD) -NBR NM 280: Conductors of Isolated Cables (IEC 80228 MOD) -NBR NM 247-2: Isolated cab:es with PVC for nominal voltages up to 451JJ750V, Part 2: Method oftest (IEC 60227•2 MOC) Fiber optic cable -Mulli-nmde or sirigle-mode fiber for data transfer : -Flame-retardant PVC jaoket -Fiber performance: ITU-T G.65'l, G.652, G 655 orG.657 -Acl')'lale-o::ated opllcal fiber With a thermoplastic secondary coating -Aramid yarn layer and a PVC jacket to protect tile fiber ' ·SDT235•350-709 (TELEBRAs) • NBR 14106 (ABNT) ------------ Structure Diameter coirugated aluminum armor; mm (in} [ Diameter over jai;:ket nominal, mm {in) I UV-proU"etlon {individual and external Jai;:ket) • outer cc,n~uct:ir equi~alent to LCF12-50JL •• outsr conrt.Jctor equiV11lent to LCF78--50.JL Mechanical properties ! ·si~gle~~ding radius, mm (in] i Multiple ~ding radius, mm {in) i Cable weight, kg/m (lbfft) : Rei;ommended/Maximum clamp spacing, m (ft) 1-sectorcable . 13_80 (0.54)~ 15.80 (0,62) Yes i 0.22 (0.15) ! 0.6/1.0(2.0/3.25) i Bubblewrap 3-sector cable ---· -----·--·· --·-·-----, 25.20 (0.99) --~~ l 27.80 [1.09) Yes 0.55 (0.37) 0.6 /1.C (2-75/ 3.25} -·-···-, Bubble wrap L Co~rs protection during hoisting pro~ .. -··-··-.. ·"·-· . .. . . i ·-··---·-·-······-···· Electrical properties ' , DC-resistance aluminum armor, 0/km (C/1000ft) 2.78 (0.85) r·cc·~~;~~flCe power cable.'Olkm (0/1000ft). __ ._ •. ---·-·-···· ... · ___ ,.. . ( 2.5rnm2 = 8.21 (2_5) . 2.5mm' = 8.21 (2_5) Fiber optic properties Fiber optic version Multi-mode or single-mode MulTI-mocfe or single-mode Fiber optic core/clad (1:1.i:1'.1L .. __ . ----·-------"_ ... L.50/125 or 91125 50/125 or 9/125 Fiber optic prima,y coating _(~_':!)/late} (µm) ! 250 250 Fiber optic secondary protection I.PVC} (1-1m) WO 900 Environment Installation temperature- I Opercition temperature ANTENNA JUMPER CABLE TMA (OPTIONAi.) -l•li--·-- Grounding Specifications .2o·c to +oo·c " •••• .. •~••••a•-•-•••--•--•• -•• - ·20"Cto +65"C Aluminium OC P~ external jaci<et Power ca~ (pair) with an intemal jacket {PE} • Jill I RADIO FREQUENCY SYSTEMS T h e C ! e a r Cho!ce 0 Fli¥BRIF'tEX™ RRH Hybrid Feeder Cabling Solution @ RFS' HYBRIFLEX RRH hybrid feeder cabling solution combines optical .fiber and DC power for Remote Radio Heads (RRHs) in a single lightweight aluminum corrugated cable, making it the world's most innovative solution for RRH deployments Features e Aluminum corrugated armor with outstanding bending characteristics e Installation of stripped fiber optic cable pairs directly to the RRH (individual UV•protection jacket) 0 Accessories common with RFS standard 1/2-inch and 7/8-inch feeder cables (grounding kits, hanger kits and wal!glands) o Optical fiber and power cables housed in a single corrugated cable • Outer -conductor grounding e Robust cabling • Connects up to 3 sectors with a single cable • Minimizes installation time e On~site and pre-connectorized options • Eliminates typical need for junction boxes • Supports CELLFLEX® accessories range • Extremely lightweight aluminum construction Benefits o Minimizes installation time and enables mechanical protection and shielding as well as the ability to ground the RRH • Reduces capita! expenditures (CAPEX) and wind load by eliminating need for interconnection or split•up boxes o Reduces inventory requirements and simplifies installation logistics • Saves CAPEX by standardizing RRH cable installation and redudng workforce requirements 0 Eliminates usual grounding cable and saves installation costs • Eliminates need for expensive cable trays and ducts CD Decreases tower load & Lightweight alumirnim solution and compact design 0 Outdoor polyethylene jacket ············'···· • Bulk delivery and factory pre-terminated options available • Ensures long•lasting cable protection ---- • Provides the ability to ctioose the right approach for each deployment scenario WIRELESS MOBILE RADIO MICROWAVE IN·TUNNEL IN·BUILD!NG 'TV & RADIO HF & DEFENSE www.rfsworld.com (N) HYBRIFI.JEX CABLE SPECIFICATIONS SCALE: NONE NOT USED SCALE: 6" = 1'-o· 19 NOT USED SCALE: 6" = 1 • -o· 20 SLOTTED UNISTRUT MAC.HINE OOL T 4 NUT SPRING NUT SLOTTED UNISTRUT LOCK it'IASHER MAC.HINE OOL T - SIZE AS NOTED EQUIPMENT 6RAC.KET RA YCAP BOX SPECIFICATIONS SCALE: s· = 1'-o· NOT USED SCALE: 1:3.41" 1e,.s" MAX. MAX. SIDE VIEW FRONT VIEW 15 16 RA YCAP BOX SPECIFICATIONS ' (N) Y.."DIA UNl5Tl<IJT 60LT TOP AND BOTTOM (4-TOTAL) (N) UN15Tl<IJT PIOOO TOP AND BOTTOM (N) RAYC-AP (MAX . ..,,-. :50Le5J COND. 1 WORMSEYE VIEW ' (I ' ' ' (I , 16" ~ 10" , , ' c::::J -I ' I;;. ' I _, "' "' "' © "' "' FRONT VIEW ffl. - [::JC: ' '-n1 © I;;, "' Tl MOUN Ne 6RAf:.KET A5 S<IPPLIED 6Y RAYC-AP MANUFAC, TURER COND. 1 SIDE VIEW (N) 3/&" 1.J'·BOL T TOP AND BOTTOM (N) 1/4"'° UN15TRUT BOLT TOP AND BOTTOM (4-TOTAL) \, COND. 2 HOR.Z. UNISTRUT A5 OC-C.UF':5 COND. 2 MOUNTIN<,; PIPE (N) UN15Tl<IJT PIOOO TOP AND BOTTOM COND. 3 (N) 1/4"'° UNl5TRUT 60L T TOP AND BOTTOM, TYP. (4•TOTAL EAC.H c-oNDITION) (N) S/&" 1.J'·BOL T TOP AND BOTTOM (N) 1/4"'° UNl5Tl<IJT SOL.T TOP AND BOTTOM (4-TOTAL) (N) 1/4" SPRIN6 NUT AND BOLT ® (N) UNl5Tl<IJT PIOOO TOP AND BOTTOM MOUNTINe PIPE COND. 3 SIDE VIEW (AT STRUT FRAME) NOTES: (AT PIPE MOUNT) RAYCAP MANUFACTURER SPECS: RAYCAP MODEL: RxxDC-4750PF-48 RxxDC-3103PF-48 RxxDC-3315PF-48 PHYSICAL DATA HEIGHT 'H': 25.66" WIDTH 'W'· "15.73" DEPTH 0' "10.25" NET WEIGHT: UNIT+MOUNT 21 ,5# USE: SURGE PROTECTION NORMAL OPERATING VOLTAGE: 48V DC MAX. OPERATlNG VOLTAGE: 75V DC SKIN: UV RESISTANT SAFETY STANDARD: UL 1449 25.66" 25.66" "15.73" 15.73" 10.25" 10.25" 24.2# 26.9# CABLING: POWER, FIBER OP1lC OR HYBRID CABLES UP TO 2" DIAMETER 1. VERIZON TO SUPPLY POWER/FIBER JUNCTION BOX. VERIZON WIRELESS G.C. SHALL SUPPLY ALL OTHER MATERIALS AND INSTALL ALL MOUNTING HARDWARE. 2. 3. 4. 6. 7. A SUPPORT FOR A SINGLE POWER/FIBER JUNCTION BOX SHALL HAVE A MINIMUM OF TWO ANCHORS/FASTENERS FOR EACH UNISTRUT CHANNEL. ANCHORS AND UNISTRUT CHANNEL SHALL HAVE HOT-DIPPED GALVANIZED FINISH. MOUNT JUNCTION BOX TO UNISTRUT WITH UNISTRUT BOLTING HARDWARE AND SPRING NUTS. TYPICAL FOUR PER BRACKET. SUBCONTRACTOR SHALL SUPPLY. MOUNT JUNCTION BOX TO UNISTRUT WITH UNISTRUT BOLTING HARDWARE AND SPRING NUTS. TYPICAL FOUR PER BRACKET. SUBCONTRACTOR SHALL SUPPLY. INSTALL ANCHORS/FATENERS Al A SPACING OF NOT UORE THAN 24" o/c -WOOD STUDS: Y,"• LAG BOLTS w/ MIN. 1" EMBEOMENT IN WOOD. -CONCRETE,½"• !<Lil KWIK BOLTS •/ J½" EMBEDMENT OR EQUAL- -THROUGH BOLT,½"• AJ6/l>J07 THREADED ROD •/ NTS/WASHERS. 8. ANCHORED UNISTRUT SHALL HAVE HOT DIPPED GALVANIZED FlNISH. 10 (N) RAYCAP BOX DETAIL SCALE: 1· = 1'-0" REMOTE RADIO UNIT: PHYSICAL DATA HEIGHT ('H'): WIDTH CW'): DEPTH CD"): NET WEIGHT: 1e,.s" MAX. TOP VIEW STANDARD VERIZON RRUS UNIT 27.17" MAXIMUM 18.5'' MAXIMUM 13.47"MAXIMUM 1 02#MAXIMUM ATTACHED TO VERIZON SUPPLIED UNISTRUT W/ IIAN\,f. l'ROl,OED UOUNTING IIRACKET PER IW<UF. SPECS. (SEE NOTE I) ATTACHED TO VERIZON SUPPLIED PIPE W/ MANUF. PROVllEO IIOUNTING BRACKIT PER MANIIF. SPECS. (SEE NOTE 1) RRUS PER PLANS----.__ STANDARD MOUNTING----._ PIPE AS OCCURS LOCATION OF~----.__ SCREWS (TYP. OF 4) -----PlOOO UNISTRUT CHANNEL OR EQUIVALENT (2 TYP), ANCHOR/ FASTENER (SEE NOTE 3) ISOIEIHC YEW I\NS'TIIUT ATTACH.elJl ISOIEnlC VEW <Pl'E ATTACH.elJl NOTES: r-----~-------------7 1. 2. 3. 4. 5. 6. 7. ERICSSON SUPPLIES THE RRUS. VERIZON WIRELESS G.C. SHALL SUPPLY ALL OTHER MATERIALS AND INSTALL ALL MOUNTING HARDWARE. A SUPPORT FOR A SINGLE RRU SHALL HAVE A MINIMUM OF' TWO ANCHORS/FASTENERS FOR EACH UNISTRUT CHANNEL ANCHORS ANO UNISTRUT CHANNEL SHALL HAVE HOT-DIPPED GALVANIZED FINISH. MOUNT RRUS TO UNISTRUT WITH 3/8"111 UNISTRUT BOLTING HARDWARE ANO SPRING NUTS. TYPICAL FOUR PER BRACKET. SUBCONTRACTOR SHALL SUPPLY. NO PAINTING OF THE RRU OR SOLAR SHIELD IS ALLOWED. MOUNT JUNCTION BOX TO UNISTRUT WITH UNISTRUT BOLTING HARDWARE ANO SPRING NUTS. TYPICAL FOUR PER BRACKET. SUBCONTRACTOR SHALL SUPPLY. INSTALL ANCHORS/FATENERS AT A SPACING OF' NOT MORE THAN 24 .. o/c -WOOD STUDS: 1/4N~ LAG BOLTS w/ MIN. 2N EMBEDMENT IN WOOD. -CONCRETE: t/2•~ HILTI KWIK BOLTS w/ 2" EMBEDMENT OR EQUAL. -THROUGH BOLT, 1/2"0 A36/l>J07 THREADED ROD w/ NTS/WASHERS. 6. ANCHORED UNISTRUT SHALL HAVE HOT DIPPED GALVANIZED FINISH. : PROVIDE 40" 1 CLEAR; FRONT I • a,' OF RRU I U"') d I I I I I I I : a· CLR. 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 . "" "' --' '-' 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 a· CLR. L---------_________ j SCALE: NONE 1 2 (I) ~ cu 0 D (I) > e Q_ Q_ <{ ~ 0 1--Q_ w LL (I) o/5 ([ ([ z 0 <{ - f:: = 2 0 N •-I.. 0 <( <Co 0 ..---0,- (J)•a:o wo~C\I rr: <( w CJ) :)WW<( Of-a:o CJ) _JO •- -I >--:.C")z<C Wchzm 2 s :::J ~ <(<((J)CI: z --o <( w c:00 f-(Y) -(Y) CJ) w w (J) __J ~ w 0 __J <( a: :::J I-0 w I- I 0 0: <( (j) 0.. 0 1-- ::J Q w w 0 0 0 I'-- ' CD CX) N OJ st Q2, (J) (9 z s <( a: 0 z 0 I- 0 :::J a: I- (J) z 0 0 A-7 Job No. 1701N