Loading...
HomeMy WebLinkAboutCDP 15-42; Corbin House; Planning Commission• ----------------------- I. _I -~---- NEW_~ SIDENCE for --DAI~E & DEBIIIE CORBIN YUKI LN. _,CARLSBAD I' ' ' c - I !I Iii Ill,_ ' ~~-~ ~1:1 1!1 « 1-~·:= I 11-=Jc=JCJ I ~I i L __ _il c=li --- --- ~~-~~~ I I !:c=l i~ _ _JI~ J r:-71 l ' ' CITY OF CARLSBAD PLANNING COMMISSioN caseName: "aJ::bi!;l tto~e Case No.: vi) P IS~ If~ 1.'Ait \If It Exhibit No: ~ !late: 1 {.& lte PLAN INDEX !.ILLUSTRATION 2.PLOTPLAN 3.EXISTG' GRADING PLAN 4.1ST & 2ND FLOOR PLANS S.FOUNDATION PLAN 6.FLOOR FRAMING PLAN 7.FRAMING SECTIONS 8.FRAMING SECTIONS & SHEAR TRANSFER DETAILS 9.SHEARPLAN & HEADERS lO.ROOF PLAN & DECK PLAN ll.STAlRCASE & DETAILS 12.ELEV ATIONS 13.ELECTRICAI. PLAN 14.ENERGYDOCS -· PREPARED BY /I'P'~· ~~ HIRAM S. ANDRADE &ASSOC PLANNING & DESIGNS --------· ph. (760) 746-2558 -----~--- ':?-I Co-I '5 &.\1. I0-1-IS * -- .,. __ ! • ~ORTH LEGAL-Lot 3-Parcel Map 21144 APN. 207-360-55 LOCATION MAP ' • RESIDENTIAL GREEN BUILDING STANDARDS -SEC. "303.1-1 Recycling. -a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. Recycling. - _ _ ·the conl!actor shaD submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management. per CGC 4.408.2. Operation and maintenance manual. ..;. _ _ _ .-the builder is to provide an operation manual (containing information for maintaining app6ances, etc.) for the owner at the time of final inspection. CGC 4.410.1. Pollutant control. -.tRat during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. PoDutant control. -VOC's must comply with the 6mitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, catpet and Composition Wood Products. CGC 4.504.2. Interior moisture control. -1he moisture content of wood shaH not exceed 19% before it is enciosSd in construction. The moisture content needs to be certified by one of 3 methods specified in Section 4.505.3. Building materials with visible signs of water damage should not be used in construction. The moisture content must be detennined by the contractor by 'One of the methods fisted in CGC 4.505.3. Indoor air quality. -. -bathroom fans shall be Energy star rated, vented directly to the outside and controlled by a humidi§tat. CGC 4.506.1. -M 0 T E - . prior to final inspection the licen~ contractor, ~rehitect or engineer in responsible charge of the overaU construction must prov1de to the buHding department official written verification that aU appficable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 1 02.3. "EVSE" -electrical vehicle supply equipment (EVSE} is required in aU new residEmtial construction. The location _of the eleetrieal vebicle supply _ equipment is to be shown on the Eledrleal Plan 4 must consist of minimum 1" conduit extending from the main panel to a junction box where the EVSE receptacle will __ be provided. The main service panel must be sized to accommodate 208/240 Volt, 40 amp dedicated branch circuit -- Storm Water-Projects whice1 disturb less tlian one acre of soil shaH m8r1age Storm water drainage during construction by one of the foUowing: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shaD be filtered by use of a barrier system, wattle or other approved method. CGC 4.106.2. Grading & Drainage site grading or drainage system will manage aU surface water flows to keep water from entering buildings (swales, water collection, French drains, etc.). CGC 4.106.3. · 4411 z"B 1+ zi ·r , Green Building Standards --- Irrigation -automatic irrigation syslfJm controllers shal comply with the CGC Seclion 4.304.2 as fcUows: Weather !lased controllers shall have separate wired cr wireless rain sensor which conneciB or communicates with the controller(s). Soil moisture based controDers are nat required to have rain sensors. ~ I Budget -far new !'BS!Cfential conslrUctian where lancltocape Irrigation wal8r Is planned a water budget shall be developed that canfonns to lacallandscape Cldinance or the CaflfDmia Depa-of Water Resoun:es Model Water E~ l.andBCII()II Ordinance (MWELO), which ever is more stringent t -~-... -·-1 \ \ ------- R-1 ZONE DESIGNATION -- RLM GENERAL PLAN LAND USE DESIGNATION MAX BUILDING HEIGHT 24 FEET (Proposed 23 Feet) PARAPET Allowed to extend 4 ft. above the 24ft. -· ' ' ' \ , ,' \,. .. ·· ----------------- ~ITY DISTRICTS WATER DISTRICT-CARLSBAD SEWER DISTRICT-CARLSBAD SCHOOL DISTRICT-CARLSBAD SET BACK TABLE- FRONT-20ft. SIDES-l'*t. REAR-20ft. -. THIS LOT WAS PREVIOUSLY GRADED THE LOT HAS ALL UTILITIES SUB TO THE SITE ------------ IMPERVIOUS AREA ROUSE & GARAGE Foot print= 2121 sq. ft DRIVEWAY AREAS= 2250 sq. ft. WALKWAY AREA= _ 82sq.ft. TOTAL IMPERVIOUS AREA=4453 sq. ft. \ \ ' ' r LANDSCAPE IRRIGATION WATER USE SHALL : HAVE WEATHER BASED CONTROLLERS ------- -Tins IS NOT A SURVEY-THE INFORMA1lONPROVIDED ON THIS PLAN AND oTHER ATfACHED SHEETS ARE DEEMED RELIABLE BUT IS NOT GUARANTEED-CONTRACfOR I OWNER TO VERIFY ALL ELEMENTS OF THIS PROJECT WITIITBE EXISTING SITE .;... THE CITY OF CARLSBAD REQUIRES THE INSTALLATIONOFABYPASSTEEAND ASSOCIATEDBALL'VALVES & BE INSTALLED ABOVE GRADE ON THE MAIN WATER SUPPLY LINE BEFORE IT ENTERS THE BUH..DING (W35) PLOT DRIVEWAY -CROSS SECTION PLAN SCALE-1" = 20' LOT COVERAGE LOT AREA= 19,083 sq. ft. HOUSE & GARAGE . . foot print= 2121 sq. ft. TOTAL COVERAGE= 11.1% ' ------- CDP 15-42 SCOPE of WORK- -Const. 2 Story SFD = 2532 sq.ft. -4 Bedrms, 3 Baths, 2 ~ Baths -3 Car Garage = 795 sq. ft. -Deck on 2nd Floor= 744 sq.ft -Covered Entry Porch = 63 sq. ft. THESE PLANS SHALL COMPLY WITH THE 2013 TRIENNIAL ED. OF THECALIF. CODE CBC, THE 2013 CALIF. ELECTRICAL CODE CEC, 2013 CALIF. MECH CODE, CMC, 2013 CALIF PLUMBING CODE CPC, 2013 CALIF. ENERGY CODE, 2013 CALIF. FIRE CODE CFC & ALL APPUCABLE CITY CODES and ORDINANCES BUILDING CODE DATA- CONSTRUCTION TYPE-VB OCCUPANCY -R-3 STORIES-2 SPRINKLES-YES THE CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF THE SEISMIC-FORCE RESISTING SYSTEM SHALL SUBMIT A WRTITEN STATEMENT OF RESPONSIBH..ITY TO THE BUH..DING OFFICIAL PRIOR TO WORK --,,.. -------·---- OWNER-. Dale & Debbie CORBIN - 4398 Yuki Ln. Carlsbad, CA 92008 ph. 760 214 3032 • PREPARED BY ~p ,/~ HIRAM S. ANDRADE & ASSOC. .. PLANNING & DESIGNS ~ ph. (760) 746-2558 . ,, ; • I I( 22-o : nf-oil . ' I 1 1 , -~~ I 4:_c.; 14"' CLo;.e-r MASTER PEDROO~ \ ~ '/( \ c.,(. r -,-- ·1 .,_1 11 ::;;;-o ... 2nd ·• PLUMBING NOTES -PERM.~NENT VACUUM BREAKERS SHALL BE INSTM.LED WITH ALL HOSE BIBS -PROVIDE ULTRA LOW FLUSH TOILET, 1,28 GPF (MAX) & MAX 1.5GPM FOW ON FAUCETS@ KIT, LAV. & BAR SINKS T z4-xt•o6S SLWI>-11:> ~~ j z•xz!"or;,s.6ff,WuvD. I , I I ~t:( I 1~ 3G;_, I --·,.,-,. . Z"X8'fr>' WiNV. TEMP. DECK z/-o'' L -SHOWERHEADSTOHAVEMAX.2.0GPM FLOW -SHOWER WATER VALVES TO BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES I L. 00 ';. !==I "'o o I ' Dol· I It>"" r 1:_ _: _r ~: I ) ! r I· ' 7 '-o'' t ______ . -------. -·-o---~~ '-t/ FLOOR PLAN = \377 "?a. f"T c- NEW WINDOWS TO BE VINYL FRAMED _ _ _ __ ~ --_ -DISCHARGE POINT FOR ANY EXHAUST AIR WlLL BE AT LEAST 3FT. FROM ANY OPENING WHICH ALLOWS AIRENTRYINTO THE BUILDG. -PLATES CUT FOR PIPES SHALL PROVIDE A METAL TIE MIN .058 THiCK x 1.5 IN. & SHALL BE FASTENED ACROSS THE OPENING w/ (6) -6-d NAILS MIN. EACH SIDE ~~--- .-> -DRYER VENT TO OUTSIDE-4 IN. GALV. PIPE MAX. 14FT. LENGTH, MAX OF (2) 90% BENDS -WATER CWSETS TO BE IN A ~SHO}VER, SHALL 6E . _ · 30" CLEAR WIDTH SP~CE & TABLE 4,303.i FIXTtJlU. FLOW RATES TILE WAINSCOTING TO 72 IN. w/SHATTER 24" MIN. SPACE IN FRONT b~~~~;=~~~~~~~~E~~~J PROOF ENCLOSURE & DOOR AT<! 20 % -EXHAUST FAN TO BE VENTED THROUGH I ·--Hot Water piping sized%" or larger is . ROOF TO EXTERIOR . -SHOWER PAN TO BE HOT MOP & 15 LB. FELT required to be insulated w/1" insulation ; %"size hot water pipe to the Kitchen HEATING-PROVIDE TWO o/." COPPER PIPES sink is required to ~insulate<! __ ATTHEROOFFORFUTURESOLARPANELS \ ----J BEDROOM2 lZ"~ (\" BEDROOM! \Z"'Xf'lb t 1o' -'711 '2-7 ~ o'' 1 ---· ' BEDROOM3'' \19 x w•C-- OFFICE I STUDY ' l 0~ )( '"'" 2. ~vatory filu~ shall not have a flow mte less than 0.8 gpm at 20 psi. AN APPROVED OUTSIDE TANKLESS WATER HEATER IS TO BE PROVIDED & TO COMPLY w/ MIN. DISTANCE REQS. & MANUF. SPECS. ~o"i'E-~T WA"W.<;<. pt p•r-.IC:, T'o , BE A.L.l.. o V€\Z-1\.~ '\::> TANKLESS WATER HEATER RHEEM-No. EC0200XLP3 9.5 GPM -199,900 BTU_s \ '1'7/JOO 6TLI = \ CjZ..Zcu'f'\-j~v::_ \040 LeN<'AT~or 'Ptl?€. 5bFI ?ee TA.\'St..E. "=/A.S PtpE'5'1ZtN~ \'liEeG.. pt .pE. < Z5~ e.u?if/~0:. ~ ~1"\. ., I •I ""'-o I I '' 2-o . h' ... do''' l 1st F~OOR PLAN- t..! GARAGE 1'---<i-----(j---~ $'X8" MeTAI.,(>YI":P: fiei<J) DR. ' ·---. -. ,-' ---~ . z(-o'' "f'o~-"OALe ~~ee~eeoe.e.tl'l 4398 Yu K.\ . \..o.-1-.1. C A I':.(.S SA\::> DOUBLE GLAZED-SLIDING OR AS NOTED THE MANUFA<;TURED WINDOWS SHALL HAVE A , , SCALE-ALL WEATHER-EXPOSED SURFACES SHAJ,LHAVE A WEATHER-RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING AND THAT EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF To-rA.L ~ Z532 -?<>LfT. -GARA~f..-:73s~,f7,..:=:;/:~=:S&ASsoc. -. . ·-·--... .. -----------.LABELATTACHEDCERTIFIEDBYTHENATIONAL VINYL FRAMED WINDOWS SHALL HAVE . FENESTRATION RATING COUNCll. (NFRC)AND ~-WELDED CORNERS & METAL ; · REI!'ffi_ORCEMEJ'<T IN'fiiF:INTERWCK~ i SHOWING COMPLIANCE WITH THE ENERGY CALCULATIO~' --. ~K = 71-il.f?r;:z..f-1, ph. (760) 746-2§58_ --------------·· ---------------- . .