Loading...
HomeMy WebLinkAboutCDP 2019-0002; HILLSIDE RESIDENCE; Planning CommissionI • ,, \ \ SITE ~ , CITY OF PACIFIC \ \ ,r, OCEAN ._,_, ~Ii> ._;.· .. ·-·,::• -·. VICINITY · MAP NOT TO SCALE: j NOT TO SCALE T8fP CONSlR/JC710N --.... £SI.IT FOR· GRAOJNG PER ooc j2005-0J47468 E:X IN/£T (TYP) ~ ,,, '><. . I '\ ~:-I ~ \V . "' \»';, \l\~i 6' RET. WALL \»~ \\\9' ;,~ 1/. . . \ /· ~ -z.. .. <;; ;:,- · ~ ~ \ \ ,9, \ . ·~~ \;, .. \ \ ~ . " -z.. / APN: 207-022-36 ·~ . IN,PERVlOL?S ARE~ ~· . bRIVEVVAY 3160 -.s:rJ?,££' T Pt-\ V ) N (-,· .• .:too .. _Bt,J L.-1>1 N,~ _ ~ 15 lt1a . Tor.AL. PROfb5£/) ltVlt)t;'R\;'!OiJ5A~E4 ~ 486Q, -·n:,·rA L. 8,EPLAC.SD !II\A PEr~v.1ous AREi\ -I boo TorA.L L-DTAREI\ .:-2.S-AcRE;: ~ITE PL. AN TolAL Dl5TUR'8ED A,fA..f;A 1 ll'2..COSQr!:~•~.· :...:::...:::.....::.· ·--=;;;·;;;·_. --- SCALE 1." = 20' "' 0 10' 20' ! i GRAPHIC SCALE 1· = 20' @ EAR.TH WO R lZ . ~ CUT 130 <:.Y F! LL-I 060 CY ToTAL C,5'o (,l( LOT COVERAGE I LOTAREA=-1 l,191 SQ.FT. FOOTPRINT AREA= 1535.S SQ.FT. 11, 191/1535.5= 13.72% SITE PLAN FOR SMITH RESIDENCE 42LJG 1-IILL S tDE DRIVE . PRoJECT:ff:, Ct,P·ZOl9 -000>2. CITY OF CARLSBAD PLAN~::;5&/P Case Name: U,l;,,fJJ_ Exhibit No.: {/), FIAE SPf-<!NKLfRS THRLJcur O ~NFPA 13.Do THIS PROJECT WILL COMPLYWITH THE FOLLOWING BUILDING CODES AND ASSOCIATED CITY OF CARLSBAD AMENDMENTS: · 2016 CALIFORNIA RESIDENTIAL CODE (CRC) AND OR 2016 CALIFORNIA MAIN HOUSE AREA BUILDING CODE (CBC) AS APPLICABLE 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE ( CALGREEN) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA MECHANICAL CODE (CMC) . 2016 CALIFORNIA PLUMBING COOE (CPC) .,. 2016 CALIFORNIA FIRE CODE (CFC) · 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS (CBEES) THIS PROJECT WILL COMPLY WITH THE . COUNTY OF SAN DIEGO LIGHTING ORDINANCE c.rV!L. EN6\t-./Ef'.F BEN LUNI) 76o•4\0·Bl71 .. LIVING AREAe= __ l 848.0 SQ.FT•---------.. ---- . • 2ND DWELLING ___ 638.0 SQ.FT. __ ,_-------· TABLE OF CON-TENTS GARAGE-----611.5 SQ.FT·--,..----. . PAGE#" CONTENT PORCHES ,,, ___ 177.5 SQ.FT. _____ _ ST-1 SITE PLAN QJ?~ ~T-2 SITE we,LLS & ELEVATION .,;...__--------·---* PLANS BY RON LINVILLE 804 PIER VIEW WY SUITE 207 OCEANSIDE, CA. 92054 . * ALL WORK SHALL COMPL y WlTH ALL CURRENT CODES AS ADAPOTED BY THE COUNTY AND STATE OCCUPANCY= FOR HOUSE R-3, FOR THE GARAGE U TYPE OF CONSTRUCTION"' V-B SCOPE OF WORK: BUILD NEW HOUSE AND ALL. THE WORK ASSOCIATED WITH ACCOMPLISHING THAT TASK OWNER: JESSE SMITH PHONE#: . (760) 504-8987 ADDRESS: 447 BOUGHER RD. SAN MARCOS, 92069 smADDRESS: 4246 HILLSIDE DR , CARLSBAD CALIF. APN : . 207-022-11 MAP 2152. BEU.A VISTA !..OT t9 19 BLOCi-<. G- 1 . 2- 3 4 5 6 7. 8 9 10 11 12 ATTACIJED . FRONT VIEW REAR VIEW,RIGHT & LEFi SIDES 1 ST FL FLOOR PLAN 2ND FL FLOOR PLAN ROOF PLAN 1 ST FL FRAMING & JOlsTI>L.AN FOUNDATION Pl.AN 1 ST FL ELECTRICAL PLAN 2ND FL ELECTRICAL PLAN CAL GREEN NOTES NOTES & DETAILS ' . NOTES & DETAILS . TITLE 24 & ENERGY . . . . PAGE .ST-1 of 12 ~IENJLUNC . / ENGINEERIN !&)2019 BEN I.IJNf) £Nfll/lEtl/m -2T190 GHAN/TE RIIJG£ /II), 92026 -{76U) 4/o--8171 -l/£/IRlllNfJOlll,IAJI.C r .. • • • •• • 25'2" + OR- ... . .-. .:. -' . · . ·--.-.• I I I . . ... : -. §II§ . . . . . ... • WEST -. -- ·SCALE 1/411=1'011 THIS PROJECT WILL COMPLY WITH THE FOLLOWING BUILDING CODES AND ASSOCIATED COUNTY OF SAN DIEGO AMENDMENTS: 2016 CALIFORNIA-RESIDENTIAL CODE (CRC) AND OR 2016 CALIFORNIA BUILDING CODE (CBC) AS APPLICABLE 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE ( CALGREEN ) 2016 CALIFORNIA ELECTRICAL CODE {CEC) 2016 CALIFORNIA MECHANICAL CODE (CMC) 201 6 CALIFORNIA PLUMBING CODE (CPC) 2016 CALIFORNIA FIRE. CODE (CFC) 201_6 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS (CBEES) -.. • • ••:I 14"X18" VENT (1.59') ______ ,.... __ _ . 6' D • ,• 9'3/4" CEILING 10'3/4" CEILING • • • MAIN HOUSE AREA LIVING AREA= __ 1 848.0 SQ.FT. 2ND DWELLING-__ 638.0 SQ.FT.~---'---------~- GARAGE ______ _ 611.5 SQ.FT. _______ _ PORCHES -. __ 177.5 SQ.FT. __ __,_ a;~ * PLANS BY RON LINVILLE · 804 PIER VIEW WY SUITE 207 OCEANSIDE, CA. 92054 *ALL WORK SHALL COMPLY WITH ALL CURRENT CODES AS ADAPOTED BY THE COUNTY. AND ST ATE THIS PROJECT WILL COMPLY WITH THE , U COUNTY OF SAN DIEGO LIGHTING ORDINANCE SCOPE OF WORK: BUILD NEW HOUSE AND ALL THE WORK ASSOCIATED WITH ACCOMPLISHING THAT TASK OWNER: JESSE SMITH PHONE#: (760} 504-8987 · ADDRESS: 447 BOUGHER RD. SAN MARCOS, 92069 SITE ADDRESS : 4246 HILLSIDE DR CARLSBAD CALIF. #2680--2862 • • •'•"•• ··:, .... . .. :·•. .-.. -. •, . . . -.. :-.• •,• ( ........... _ .......... _____.. • '''-·· ---TABLE OF CONTENTS PAGE# 'CONTENT ST SITE PLAN t FRONTIMEW 2 l'IEAR VIEW,RIGHT.& LEFT SIDES 3 1STFL FLOOR PLAN 4 2ND FL FLOOR PLAN 5 ROOF PLAN / 6 1 ST FL FRAMING & JOIST PLAN 7 FOUNDATION PLAN 8 1 ST FL ELECTRICAL PLAN 9 2ND FL ELECTRICAL PLAN 10 CAL GREEN NOTES NOTES & DETAILS 12 NOTES & DETAILS ATTACHED TITLE 24 & ENERGY RONS HOUSE PLANS SCALE: 1/4"=1'0" CONTRACTOR: DATE: 4-- OWNi;',RS CONTACT / JESSE SMITH (i/60) 724-4159 · I OWNERS PHONE# . (160) 504-8987 DRAWING NUMBER 1 OF ·12 • i .. i . 5'211 2 +O R- . 9'3/4" CEILING 10'3/4" CEILING 618'1 ~ ' ~ ,, ,~ 6'011 ' - ' ...-- --- ---- V I/ Ef □ □ TT - . ~ J. ~ -_J _.. ~ -~; ''-' 1· ■ ■■ . --·----------- 14 11X2411 VENT (2.13') :;, .. ", -- ... --- . ~ . -- ~ .,,~ ., ~ ~ .. = . --•• • • • • . -----------------------------. ----------------------------------- . .. r--r- r-• • ' ~ •• • . . . EAST REAR VIEW SCALE 1/411=1 '011 ~ ~ ~ :0, :,,,, ~ ~ II 11 . ■ ■ • ■ --.... ---------------------------------~ ------------------------------- . I. ■ ■■ . ,-- □□□ ·. .- ,-------,-------,--□ ,-------,--.- □ ,-- . --r-- NORTH LEFT SIDE SCALE 1/411==1 10" □ □ . . --r---v. t--□□□ ,-,-. ._ r-r-r-I/ -1--□ r- t-'-□ r-t-1-- t--~ r-;: ~ t--□ □ r-o ,--r-□ r-r-,--r-TT - ----- -- -- .-r-- r-,--,-- ,--,- ,----....-r--r-,-- ,-- ---.. . --- . ,.... ~ ~ ~ ,.... ,... ~ ... _/ r 9'3/4" CEILING . 6' p" 25'2 • " -----R-+ fJ . ,.... ~ - 10'3/4" CEILING ' . . 6'~" • FUTURE SO PHOTOVOLTAIC 250 SQ.FT. ¥ .. . . . ■ ~ . •• •• . ------------------- ----------- - C - . . CHIMNEYS SHALL EXTEND AT LEAST 3' ABOVE THE HIGHEST POINT WHERE IT PASSES THROUGH A ROOF ABOVE THE HIGHEST POINT WHERE IT PASSES THROUGH A ROOF AND AT LEAST 2' HIGHER THAN ANY PORTION OF A BUILDING WITHIN A HORIZONTAL DISTANCE OF 10' CMC SECTION 802.5.2.1 DECORATIVE SHROUDS CAN NOT BE INSTALLED AT THE TERMINATION OF CHIMNEYS FOR FACTORY BUILT FIREPLACES, EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC·SYSTEM AND tNSTALLED . - IN ACCORDANCE WITH THE MANUFACTURES INSTALLATION INSIBUCTIONS . - - ~ ~ •• . ■I ------ --- !I [] [] l[] l[] AJll.JRE SOLAR PHOTOVOLTAIC MIN. 250 SQ.FT. 3' FROM HIPS AND VALLEYS 3' FROM RIDGE MIN. 80 _SQ. FT, & 5' DIMENSIONS FROM ANY HIGH OBSTRUCTIONS MIN. 2X THE HEIGHT_ OF THE OBSTRUCTION . • ...--. \ o' -~ - 11 • I • • ■ -------- -___ _, ~ . •• SOUTH -1 .,,. ~ ~ = ~I -= . I - 14 I\X24" VENT (2.13') I " • --------~------- ------ . ~ . . ~ ----..J 9'3/4" CEILING 6' t:SII 25'2 " +p R---- 10'3/4" CEILING ' 51:,,11 ~ • ROOF VENTS: VENTS REQUIRED 1562' GARAGE AREA + 150= 10.42' RIGHT SIDE TOT AL RE UIRED= 10.42' ALL ATTIC VENTILATION OPENING _SHALL BE COVERED WITH CORROSION-RESIST ANT MET AL MESH WITH MESH OPENING OF 1/16 INCH IN EACH DIMENSION SCALE 1/4"=1'0" EXTERIOR FINISH: -HARD!PLANK TO BE INSTALLED AS PER MANUFACTURES SPECIFICATIONS. TWO LAYERS OF GRADED PAPER SHALL BE APPLIED OVER ALL WOOD BASE VENTS PROVIDED QU TYPE AREA 14 "X36" VENTS (3.2') = 14-1/2"X30' VENTS (3.02'] = 6 14-1/2"X24" VENTS f2.13'] 12.78' 14"X12"VENT[1.4'EA.J= 36" HALF ROUND DORMIERS[1.67']= 24 ' HALF ROUND DORMIERS[. 76']= TOT AL PROVIDED = 12.78' r-;:::=:::SHEAT-H-:::-:-:::-:-ING. ~~~~===-~::::::::, RO N S ELEVATIONPLANLEGEND HOUSE PLAN. s ~ STUCCO [ SEE OWNER FOR .OR • SHADED AREA ~ COLOR&TEXTURE] -••• , SCALE: 1/4"=1'0' CONTRACTOR: DRAWNBY: RTL ~ '[jjij_ ··BRICK ORROCK #2862 § SIDING [ SEE OWNER FOR i..;;g0Rl8.J VENEER DATE: 4-12-18 OR TEXTURE l OWNERS PHONE# COL & JiiAoR f;2( ROOF COVERING OWNERS NAME ~ rzga SEE PLAN JESSE SMITH (760) 504-8987 I SHUTTERS ,., WINDOWS SEE EB lirnl OWNER DRAWING NUMBER SEEOWNER PLAN ORa&! ;~~!6RJ (760) 724-4159 2 OF 12 I . I o 5' 10' I I I GRAPHIC SCAlE IIHl==lllr=lnir9nl r===i §[§] F-~ 11==11=1111=n=rnnF=u r-_ BI§ ------LEX{JR/)/JNO ------ [i[i] ·□□□□ □ □ mm·□ □□ □□ □□ .§§□ □□ □□ □□□□ □□□□ □□□□ □□□□ FRONT (WEST) ELEVATION FOR SMITH RESIDENCE - J/JLY 20, 2019 ~~INILUND ENGINEERING flll. · 920$ (7d0) 41/J-8171 -BEJlf/lllMHK,lfA/l.CON @20I/J 8£1/ ll/NC £Nfl/NW?/N(J -2779/J SIIANITc llll1GE -· SITE PLAN ELEVA_ T{OI\/ S 1·Tc !8 LAN PAGE ST-2 of 12 CITY OF OCEANS/OE \ \ \ PACIFIC \ OCEAN \ I I \ \, \ \ \ CITY OF ENCINITAS ·1 . CITY OF li/'STA ROAD ·r .. :._.<of>, h CITY OF SAN MARCOS I J VICINITY MAP NOT TO SCALE (/_ ROW Rl: 25''------tl-~-9 ·----34''--~-~--- ~12':i'+---+-----/13±' -----.----25.5''±---'--t--.5.2T3.3':i 2% EX G-1 SIDEWALK 1 -1ES3tti:Ei~~l'E:±'B4ptBti3t~~Siz~S~-1~~6 • EX 3" AC OVER 10" AB EX G-2 CURB & EX £AR11-IEN SWALE PER DWG 212-4 GUTTER HILLSIDE DRIVE TYPICAL FULL WIDTH EX SECTION I r-12':i EX EAR11-IEN SWALE NOT TO SCALE 13±' -----.----,1±' ----5~ EX AC BERM G-7 WALK , • " G-2 CURB EX 3 AC OVER 10 AB & GUTTER PER DWG 212-4 EX AC WALK HILLSIDE DRIVE TYPICAL. PROPOSED SECTION NOT TO SCALE PL I v22' ~6'._-:s, 'a . '<'.,, I 2% 1' ol -VARIES~ -5.5" PCC DWY 11 OVER 3" AB FL 0-75 RETAINING WALL BY 011-/ERS (TYP) SECTION A-A NOT TO SCALE PL r--:,· I ". ~ 1/0.0 FF • 70.9 !09.3 PAO I ~ 2!f..!!IN •0 ,....s,__ __ ~= -=~tft:~ 5.5" PCC Owrl,-i,,,..,i"" OVER 3" AB RETAINING WALL BY 011-/ERS (TYP) SECTION 8-8 NOT TO SCALE ADJUST AH RIM TO WALK FS TFMP CONSTRUC710N ESMT FOR GRADING PER DOC /2005-0347468 £)( IN/£T (TYPJ 2x2 INLET 99. 1x1 INLET 99.0 TG ~ \ 0 ~ '-" '-" Ix/ INLET 108.5 TG . \~ ~ \\ !08.5 1W 102.5 BW "' 1/ )<-,,----;,< / .,1/ 1/ s, 1/'.'. / 1/ "'o/ APN: 207-022-36 0 10' 20' • \ GRAPHIC SCALE 1· = 20' CONSTRUCTION NOTES [l RELOCATE MAILBOX lg] RELOCATE OR INSTALL NEW M-9 SIGN IJ] 18' OWY PER G-140 W/11-1 MONOL/11-/IC CURB @] 16' OWY PER G-14A ~ 5.5" PCC OWY OVER 3" AB ~ RIPRAP PER 0-40, NO. 2 BACKING, T=1.5'. 40' IZ] AC STRUCTURAL SEC710N PER SOILS REPORT. MIN 4" AC OVER 6" AB lfil EX 18" HOPE BUILT W/11-IOUT PERMIT BE REMOVED [g] 4" PVC STORM DRAIN AT 1% MIN [0 RETAINING WALL PER SORSD C-1 llli RETAINING WALL PER SORSO C-4 LEGEND: 0£SCRIPT/ON PROPERTY BOUNDARY LOT LINE EX CONTOUR EX WATER MAIN EX SEWER MAIN & AH EX STORM DRAIN EX GAS EX RR£ HYDRANT EX STREET LIGHT EX CURB & GUTTER EX FENCE SIDEWALK sro owe SORSD G-7 BROW DITCH TYPE B SDRSD D-75 SEWER LA lERAL OWG S-7 I" WATFR SERVICE & I" METFR W/ CMWO OWG W-JA I" DCV STORM DRAIN RIP RAP RETAINING WALL CONCRETE OWY AC PA 14NG {SECTION PER CITY STD} BROOKS BOX REFERENt;r DRAWINGS SDRSD 0-40 SDRSO SYMBOL -~--260--- -SD-- --G-- ~ -~------1® -----"® -so-~ CARLSBAD OWGS 196-IA, 212-4, 212-4A, 385-7, 385-7A, 411-4A SOURCE Of TOPOGRAPHY lVPOGRAPHIC SURVEY WAS PERFORMED BY RELD SURVEY BY BEN LUND ENGINEERING ON 5/1/18 AND 1/11/19. PROJECT LQCA71DN 4246 HILLS/OE DR CARLSBAD, CA 9.2008 APN: 207-022-1! Qlff\lER JESSIE SMITH 447 BOUCHER RD, SAN MARCOS, CA 92069 760-504-8987 BENCH MARK OESCRIP710N: SPIKE IN ANCHOR POLE LOCA 710N: SE CORNER OF HILLS/OE DR & HOOVER ST ELEVATION: 166.397 DA TVM: NGVD 29 LEGAL D£SCRJP71QN 11-/0SE POR710NS OF LOTS 18 ANO 19 IN BLOCK "G" OF BELLAVISTA, IN 11-IE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STA TE OF CALIFORNIA, ACCORDING TO MAP 11-IEREOF NO. 2152; RLEO IN THE omcE OF 11-1£ COUNTY RECORDER OF SAN DIEGO COUNTY, MARCH 1, 1929. , EARTHWORK QUAN7171ES CUT: 130 CY RLL: 1,080 CY IMPORT: 950 CY fAIPER'(1QlJS AREA ORIVEWA Y 3,160 SF STREET PAVING 200 SF BUILDING I, 500 SF TOTAL PROPOSED IMPERVIOUS AR£4 4,860 SF TOTAL REPLACED IMPERVIOUS AREA 1,600 SF TOTAL LOT AR£4 a25 ACRES TOTAL DISTURBED AREA 11,200 SF QUANTITY ~ CITY OF CARLSBAD I SHEETS I LU ENGINEERING DEPARTh1ENT 1 BENLUND PR£l.lMINARY BRADING Pl.ANS FOR: SAi/TH R£S/0£NC£ & HILLS/0£ OR S1HE:£T IMPROV£M£NTS GR2018-0022 DWN BY: BR! PROJECT NO. DRAWING NO. CHKD BY: __ _ ENGINEERING 27190 GRANITE RIX£, 92026 -760 4/o-at71 -B£N/I/.I/NOOG'IIAIUX/I,/ RVWD BY:. . COP2019-0002 XREFS; SMITH 7Ul1.; SMITH MAP; SMITH T0PO-SURVEY; SM!TH PREU.M GP00; SMl1H GRD * BALLOON FRAME ALL WALLS OF ROOMS WITH SLOPING CEILINGS* MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED, 2X4,3X4,2X6, STUDS IS 10'0" FOR BEARING WALLS * . MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED STUOS FOR NON-BEARING WALLS IS AS FOLLOWS: [A] 2X4 AND 3X4 IS 14' [BJ 2X6] IS 20' DOUBLE TOP PLATE TO HAVE A MIN, 48" LAP SPLICE ALL DOOR HEADER TO BE 4Xl0 UNLESS NOTED OTHERWISE . CROSS BRIDGING OR BLOCJ(ING AT FLOOR JOISTS AND RAFTERS 12" OR MORE IN DEPTH S.HALL BE SUPPORTED LATERALLY BY BRIDGING AT INTERVALS NOT EXCEEDING 8'0" , UNLESS BOTH EDGES ARE HELD INLINE. IN 2-STORY BUILDINGS, SHEAR PANELS AT THE FIRST STORY [AT LEAST 48" IN WIDTH] SHALL BE LOCATED AT EACH END OR AS NEAR THERETO AS POSSIBLE AND COMPRISE AT LEAST 25 PERCENT OF THE LINEAR LENGTH OF THE WALL, OR. PROVIDE DESIGN. TEMPERED SAFETY GLASS IS REQUIRED PER CBC 2406.4 1 JIN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE A STANDING SURFACE AND DRAIN INLET. 2] IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. HINGED SHOWER DOORS MUST SWING OUTWARD. THRESHOLDS TO BE WIDE ENOUGH FOR A MINIMUM 22" WIDE DOOR AND 22" WIDE MAINTAINED EGRESS, WINDOW AREA MUST BE 8% OF THE FLOOR AREA, OF THE ROOM SERVED (C.B.C.1205.2). OPENABLE WINDOW AREA TO THE OUTDOORS OF AT LEAST 4% OF THE ROOM SERVED (C.B.C, 1203.4). IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CBC SPECIFY 15# FELT UNDER WOOD SIDING SLEEPING ROOMS AND BASEMENTS MUST HAVE AN EXTERIOR EGRESS DOOR OR WINDOW [CBC 1026.2, 1026.3, 1026.5 J WITH: (U.B.C. SEC. 310.4 ) : A) 5.7 SQ. Ff. MINIMUM NET CLEAR OPENABLE AREA [ 5,0 SQ. FT .. FOR GRADE-LEVEL OPENINGS ] B) 24" MINIMUM NET CLEAR OPENABLE HEIGHT, C) 20" MINIMUM NET CLEAR OPENABLE WIDTH, D) BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" ABOVE FLOOR, E) DIRECT OPENING TO PUBLIC WAY ORY ARD/COURT OPENING TO PUBLIC WAY, F) WINDOW WELLS OF 9 SQ. FT., HORIZONTAL AREA AND 36" MINIMUM DIMENSIONS AND EQUIPPED WITH LADDERS/ STEPS FOR ESCAPE. FOR EGRESS DOORS: MAX. 7.75 INCHES FOR IN-SWINGING DOORS FROM TOP OF THRESHOLD TO LANDING AND 1.5 INCHES FOR OUT-SWINGING FOR NON-REQUIRED DOORS: IN OR OLIT SWINGING 7.75 INCHES LANDINGS AT iJOORS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF DOOR AND LENGTH IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36", WILL BE PROVIDED ON EACH SIDE OF DOORS. THE ELEVATION OF LANDING SHALL NOT EXCEED ONE INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY[ 8' IF DOOR DOES NOT SWING OVERT THE LANDING]. ALL LANDINGS SHALL SLOPE AWAY FROM THE DOOR MIN 1 /4" PER FOOT. CHECK WITH PLUMBING CONTRACTOR FOR ANY PLUMBING WALLS THAT WOULD NEED TO BE A 6" WALL CHECK WITH THE OWNER FOR OPTIONAL 6" EXTERIOR WALLS. INSTALL WATER FOR ICE MAKER IN THE REFRIGERATOR AREA TUB AND SHOWER TO HAVE TILE INSTALLED 70" HIGH ABOVE THE FLOOR MIN. PROVIDE LOW FLUSH TOILETS (1.28GAL) ALL WATER CLOSETS INSTALLED ON THIS PROJECT TO BE ST ATE OF CALIFORNIA, DEPARTMENT OF HOUSING & COMMUNITY DEVELOPMENT APPROVED LOW WATER CONSUMPTION TYPE MAXIMUM 1.6 GALLONS PER FLUSH TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. ALL STRUCTURAL MATERIALS OF CONSTRUCTION TO COMPLY WITH THE CODE [CBC] · ALL LUMBER AND PLYWOOD WILL BE GRADE STAMPED BY AN APPROVED INSPECTION ANGENCY. ALL WATER HEATERS REQUIRE A MINIMUM OF 2 STRAPS [ ONE STRAP AT TOP 1 /3 OF THE TANK AND ONE STRAP AT BOTTOM 1 /3 OF TANK] TO RESIST HORIZONTAL DISPLACEMENT. STRAPS TO BE A MINIMUM OF 3/4" X24 GAUGE STRAPS WITH 1/4" X 3" LAG BOLTS ATTACHEO DIRECTLY TO THE FRAMING [C.P.C. SEC 508.2] ALL NEW GLAZING [FENESTRATIONS] WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOW THE U VALUE. CHECK WITH OWNER FOR COFFERED CEIUNGS,LIGHT SOFFITS, SOFFITS FOR HEAT VENTS, CABINETS SHOWERS, TUBS, ECT. OWNER TO CHECK WITH THE.HEATING CONTRACTOR FOR.THE PLACEMENT OF THE HEATING DUCTS. AND THE AREA REQUIRED TO BE SOFFITED OR FURRED DOWN. THESE PLANS AND ALL WORK SHAU. COMPLY WITH THE CALIFORNIA BUILDING STANDARDS CODE FOUND IN ST ATE OF CALIFORNIA TITLE 24 CCR 51' ii~Y•l'.lit:t~gtfrl,~:%it?t;;;} (•:•:•:•:•:•:•:,:,:-;-:-:-:,:;:-:•:•:;:•1 IIIIIIII I II llll Ill llll . WATER HEATER T ANKLES$ RHEEM RTG-74XN-1 W14•7 /B"XD11-1/8" SANYO HEAT PUMP #24KS72/24KLS72 SEER=20 EER=11.7 BTU= H 24,200 = C 24,200 X H2S-3/8" MIN. 12" INDOOR (!,NIT = 41-1 5/16" H= 11-23/32" D 8-19/3t" W=26.5LBS ENERGY F/R .82 - _______ A_B_O_,V-E-GR-J.O'-U-ND----,-----,.----,,.L---;O~UT7" UNI =35-7/17" H=29-1/8" D= 12-7/16" W= 97.0LBS ' ' TEMPERED GLASS 2 ' -----------------,-------42• I / --------~-'----,:.,__-22·-------,~-----1..V/ . I / , i.---------1s1611 _______ __,..,...>--'4'.6"-_,,."'"---s'611---,.,.1---+------16'611 =..:::.'------4.4 TEMPERED GLASS +;2,6., / ~4, ______ ..;.f:,.1/.,i -~.4•--------11'6"-----+1 TE PERED GLASS -------13•-----¼---3--" 11x410" // ENTRY GREAT ROOM 10'3/4" ING - 3'0"X1 'O" 11 SL SL W/H DINI /4" CEILING mm : '~'!~~~~ ~ ii · Ill'[! ®® ~ r;;:... EH -.-+-'I § IIJ,0 ,!7 ,a r I" .··•~ 1--..c..L~ . - 610"X6'8'1 MIRROR DOOR MASTERS 10'3/ 4" CEit • II I / I BEDROOM #2 6'0"X6'8" 10'3/4" CEILING MIRROR DOOR co -11'. 0 BE I> ACED AT OWNERS ,PPROVAL OT TO E IN THE BUILDINi SETBACKS ,,..-4,-4-.. 1.1' co IP. ' 3' " S'Ql'X4'0" 0 BE Pl ACED AT OWNERS PPROVAL OT TO E IN THE BUILDING SETBACKS 2 ' SL 1 ' '. G ,= '■ © MICRO ••= l --r--~& ~· ~~~~~·~d;n··=~~· ~~~~· _j__j r ., ,.:· :·~•~"!st':'' 8'0"X6'8" 1' ,S,:i-'•'' 3'6"X3'0" ·,;1 ;, :.•.,:,::;.c;;)'•:i.:i': ,,.,,,,;;:'.' ·";;;;,,,,,,. fc ,;,;CY,: .,:::ii"' ··''•lYEii:::.·; ,,,,,.,,, '"""' .,,::;::;:,,. ··,:: ~.. . I SL I ,' SL ',. f I -TEMPERED GLASS I ~· '"" ' 4, W I~~~--~-~ ' ,, TEMPERED GLASS .51' l PORCH j i----4•--1-------14•---------4•-.Js.~o ... DRYER VENT [4"MIN.J ± l 3-' 14' MAX. LE GTH, '-.------~-+-T-O-P~D-E ~NE _______________ )2'6' COMBINED H'"'ZONTAL • 9'011X7'0ir SE TIONAL STEEL .>ru, GARAGE ' & VERTICAL NCLUDING INSULATED D OR ~---71-6"--~.i,'i,,I [2] 90 DEG. LEBOWS I+-«,' -10' II 10'3"+0R-CEILING AND SHALL E EQUIPPED 1' , i 7' 316" TEI "ERED GLASS • u 1 RI 'R 9'0"X7'0" SECTIOl'IAL STEEL INSULATED .DOOR . :':;: >./.:_;:1.<2i-¼ri~:'.-;:.a·/,:,. 5'0"X4'0" SL DOOR CUT TO FIT 14--<> o'6" -ii WITH BACK )RAFT DAMPERS AND MUST .RMINATE A MIM. GARAGE 10'3"+0R-CEILING S'0"Xf'0" SL I I ' · .. ·,:, :~,,~::-:::.:_ ~::-c:;~",:L;(, C ' '>, "ifl.'·-_.,_ .. o•·;.:s::-;i;t, 3' OM AN OPENING. C 04 WATERHEA R TANKLESS R EEM RTG-74XN-1 14--4••--1-~1---s•·---~--4's11 -""'---1"---1~~---~.4•--i i,.i-----------:20·-----------.t I I I t-------TOP FLOOR DEC CANTILEVER ) ___________________ J ,....------------22·------------.J .... --------------'-----'----.;.;...--.42•--'---,-.;,_---,-'-----.---,-----------1 FLOOR PLAN LEGEND NEW FULL HEIGHT WALLS l::::iSSS''S9 HANDRAIL OR PARTIAL WALL EXISTING FULL HEIGHT WALLS r , HEADER OR WALL OPENINGS 1ST FL HOUSE LIVING AREA-·--~----- 924.00 ft' WINDOW, SLIDING, GLASS DOOR ~ OR MIRROR DOOR RETAINING WALLS SHELF AND POLE DECKS PORCHES -GO.OO ft ' GARAGE= 300.00 ft' + _]_ 11.50 ft' SCALE 1/411 =-1'011 WHERE TOP PLATES OR SOLE PLATES ARE WT FOR PIPES, A METAL TIE MINIMUM OF "0,058" INCHES THICK AND "1-1 /2" INCHES WIDE SHALL BE FASTENED ACROSS THE OPENING WfrH 6-16d NAILS MINIMUM EACH SIDE. CBC DOUBLE TOP PLATE TO HAVE A 48" MIN, LAP SPLICE PROVIDE B-16d LAP SPICE NAILING MIN. CBC. 2308.9.2.l. THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTED BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: 1] WATER CLOSET, GRAVITY TANK-TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX. 2] SHOWER HEAD = 2.0 GPM MAX. 3] KITCHEN FAUCETS = 1.8 GPM MAX. . 4]LAVATORY FAUCETS= 1 .2 GPM MAX. 5] URINALS .S GALLONS PER FLUSH } IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENT VACUUM BREAKERS SHALL BE INST ALL ED WITH ALL NEW HOSE BIBS. FIRE STOPS AT THE FOLLOWING LOCATIONS PER CBC 708. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10' FOOT INTERVALS ALONG THE LENGTH OF THE WALL; B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CBLINGS; C. IN CONCEALED SPACES BETWEEN ST AIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND INLINE WITH THE RUN OF ST AIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED; AND 0. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS. E. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY-BUILT CHIMNEYS .. PRIOR TO CONSTRUCTION THE FRAMING CONTRACTOR AND THE HEATING CONTRACTOR ARE TO DETERMINE WHERE , THE HEATING DUCTS, RETURN AIR, ECT. ARE TO GO. EXTERIOR WINDOWS, WINDOW WALLS, GLAZED DOORS. AND GLAZED OPENING WITHIN DOORS SHALL BE DUAL-GLAZED UNiTS WITH A MINIMUM OF ONE TEMPERED PANE, OR SHALL BE GLASS BLOCK UNITS OR, SHALL HAVE A FIRE-RESJST ANCE RATING OF NOT LESS THAN 20 MINUTES, GLAZING FRAMES MADE OF VINYL SHALL HAVE WELDED CORNERS AND MET ALREINFORCEMENT IN THE INTERLOCK AREA. PROVIDE NOTE ON ELEVATION SHEET AND WINDOW SCHEDULE. SPECIFY FRAME MATERIAL AND. AN APPROVED MANUFACTURE OR PROVIDE MANUFACTURES INFO DOCUMENTING COMPLIANCE. All EXTERIOR WALLS TO BE 2X6 STUDS @ 16" O.C. UNLESS NOTED OTHERWISE SANYO HEAT PUMP #24KS72/24KLS72 SEER=20 EER=1 l. 7 BTU= H 24,200 = C 24,200 INDOOR UNIT W= 41-15/16" H= 11·23/32" D 8-19/32" W=26.5LBS OUTDOOR UNIT W=35-7/17" H=29-1/8" D= 12-7/16" W= 97.0 LBS RONS HOUSE PLANS SCALE: 1/411=1 '0" DATE: 4-12-18 OWNERS NAME JESSE SMITH CONTRACTOR: (760) 724 ... 4159 DRAWN BY: RTL #2862 OWNERS PHONE# (760} 504-8987 DRAWING NUMBER 3 OF 9 * BALLOON FRAME ALL WALLS OF ROOMS WITH SLOPING CEILINGS * MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED, 2X4,3X4,2X6, STUDS IS 10'0" FOR BEARING WALLS * MAXIMUM UNBRACED HEIGHT OF LA TE RALLY UNSUPPORTED STUDS FOR NON-BEARING WALLS IS AS FOLLOWS: . [A] 2X4 AND 3X4 IS 14' [BJ 2X6] IS 20' DOUBLE TOP Pl.ATE TO HAVE A MIN. 48" LAP SPLICE ALL DOOR HEADER TO BE 4Xl0 UNLESS NOTED OTHERWISE CROSS BRIDGING OR BLOCKING AT FLOOR JOISTS AND RAFTERS 12" OR MORE IN DEPTH SHALL BE SUPPORTED LATERALLY BY BRIDGING AT INTERVALS NOT EXCEEDING 8'0" , UNLESS BOTH EDGES ARE HELD INLINE. IN 2-STORY BUILDINGS, SHEAR PANELS AT THE FIRST STORY [AT LEAST 48" IN WIDTH] SHALL BE LOCATED AT EACH END OR AS NEAR THERETO AS POSSIBLE AND COMPRISE AT LEAST 25 PERCENT OF THE LINEAR LENGTH OF THE WALL, DR PROVIDE DESIGN. TEMPERED SAFETY GLASS IS REQUIRED PER CBC 2406.4 1 JIN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORllON OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE A STANDING SURFACE AND DRAIN INLET, 2] IN FIXED .OR OPERABLE PANELS ADJACENT TO A. DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24" ARC Of EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" .ABOVE THE WALKING SURFACE. HINGED SHOWER DOORS MUST SWING OUTWARD. THRESHOLDS TO BE WIDE ENOUGH FOR A MINIMUM 22" WIDE DOOR AND 22" WIDE MAINTAINED EGRESS, WINDOW AREA MUST BE S% OF THE FLOOR AREA, OF THE ROOM SERVED (C.B.C.120S.2). OPENABLE WINDOW AREA TD THE OUTDOORS OF AT LEAST 4% OF THE ROOM SERVED (C.B.C.1203.4). IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE. PRESSURE BALANCED OR THERMO ST A TIC MIXING VALVES. CBC SPEOFY 1 5# FELT UNDER WOOD SIDING SLEEPING ROOMS AND BASEMENTS MUST HAVE AN EXTERIOR EGRESS DOOR OR WINDOW [CBC 1026.2, 1026.3, 1026.5 ] WITH: (U.B.C. SEC. 310.4): A) 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE AREA [ 5.0 SQ. FT:. FOR GRADE-LEVEL OPENINGS ] B) 24" MINIMUM NET CLEAR OPENABLE HEIGHT, C) 20" MINIMUM NET CLEAR OPENABLE WIDTH, D) BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" ABOVE FLOOR, E) DIRECT OPENING TO PUBLIC WAY OR YARD/COURT OPENING TO PUBLIC WAY, F) WINDOW WELLS OF 9 SQ. FT .. HORIZONTAL AREA AND 36" MINIMUM DIMENSIONS AND EQUll'PED Will-I LADDERS/ STEPS FOR ESCAPE. FOR EGRESS DOORS: MAX. 7.75 INCHES FOR IN-SWINGING DOORS FROM TOP OF THRESHOLD TO LANDING AND 1,5 INCHES FOR OUT-SWINGING FOR NON-REQUIRED DOORS: IN OR OUT SWINGING 7.75 INCHES . LANDINGS AT DOORS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF DOOR. AND LENGTI-1 IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36", WILL BE PROVIDED ON EACH SIDE Of DDORS. TI-IE ELEVATION Of LANDING SHALL NOT EXCEED ONE INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY[ 8" fF POOR DOES NOT SWING OVERT THE LANDING]. ALL LANDINGS SHALL SLOPE AWAY FROM THE DOOR MIN 1/4" PER FOOT. CHECK WITH PLUMBING CONTRACTOR FOR ANY PLUMBING WALLS THAT WOULD NEED TO BE A 6" WALL. CHECK WITH THE OWNER FOR OPTIONAL 6" EXTERIOR WALLS. INSTALL WATER FOR ICE MAKER IN THE REFRIGERATOR AREA. TUB AND SHOWER TO HA VE TILE INST Al.LED 70" HIGH ABOVE THE FLOOR MIN. PROVIDE LOW FLUSH TOILETS (1.28GAL.) ALL WATER CLOSETS INSTALLED ON THIS PROJECT TO BE ST A TE OF CALIFORNIA, DEPARTMENT OF HOUSING & COMMUNITY DEVELOPMENT APPROVED LOW WATERCONSUMPTION TYPE MAXIMUM 1 .6 GALLONS PER FLUSH TWO LAYERS OF GRADED PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. ALL STRUCTURAL MATERIALS OF CONSTRUCTION TO CDMPL Y WITH THE CODE [CBC] ALL LUMBER AND PLYWOOD WILL BE GRADE ST AMPED BY AN APPROVED INSPECTION ANGENCY. ALL WATER HEATERS REQUIRE A MINIMUM OF 2 STRAPS [ ONE STRAP AT TOP 1/3 OF THE TANK AND ONE STRAP AT BOTTOM 1/3 Of TANI<] TO RESIST HORIZONTAL DISPLACEMENT. STRAPS TO BE A MINIMUM OF 3/4" X24 GAUGE STRAPS WITH 1/4" X 3" LAG BOLTS ATTACHED DIRECTLY TO THE FRAMING [C.P.C. SEC 508.2] ALL NEW GLAZING t FENESTRATIONS) WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOW THE U VAWE. CHECK WITH OWNER FOR COFFERED CEILINGS,LIGHT SOFFITS, SOFFITS FOR HEATVENTS, CABINETS SHOWERS,TUBS, ECT. OWNER TO CHECK WITH THE HEATING CONTilACTOR. FOR THE PLACEMENT OF THE HEATING DUCTS, AND THE AREA REQUIRED TO BE SOFFITED OR FURRED DOWN. THESE PLANS AND ALL WORK SHALL COMPLY WITH THE CAL!FDRNIA BUILDING STANDAROS CODE FOUND IN STATE OF CALIFORNIA rlTLE 24 CCR 1 ' • I ' 51' 2 ' ' ' ' ' S1011X41011 SL I ' SANYO HEAT PUMP #24KS72/24KLS72 SEER=20 EER=11.7 BTU= H 24,200 = C 24,200 INDOOR UNIT W= 41-15/16" H= 11-23/32" D 8-19/32" W=26.5LBS A . 0 , UNIT W-35-7/17" H-29-1/8" D= 12°7/16" W= 9i\G.©ldS-OPPLATESORSOLEPLATESARECUTFORPIPES,AMETAL TIE MINIMUM · /I --OF "0.058" INCf-lfSTHICKAND "1-1/2" INCHES WIDE SHALL BE FASTENED ACROSS •------~-------~-----7'""-_,/'---•~ THE OPENING WITH &-16d NAILS MINIMUM EACH SIDE. CBC ..... ------------------------.42•- / /; TEMPERED GLASS .. 1+--------1 s16" _______ __,..,...,__·4'6H--,,,---s's11------------1 s1611 ·7 i.--4•,--------11 '6" 210"X4'011 TEMPERED GLASS 14-21611+, .--/---'::s""•o=:,,::".X4-::-c'dJ4' l<E--------13•-------i---. ... s.H,.....3,___.., 31or•x1'd"..-+-1' SL . f'c-6" SL PLAY ROOM 9'3/4" CEILING 6'0"X6'8a MIRROR DOOR ' BEDROO 9'3/4"~-,.G I I II " 3 BEDROOM #4 6'0nX6'8" 9'3/4' CEILING · MIRROR DOOR TEMPERED GLASS I~ 81011X618'1 i:_: 316"X3'of ~ SL ~ SL 2!" 1+-4••---111'',i,o◄----a·----,,.~(,++4•+-....,. .. _1---4• ~ DEC.K··~ ~ 9' ~~O"X3'0' V ~ V TEMPERED GLASS ' ' rt\ .. ON @ 12 18 RISERS BEDROOM 2'6" 9'3/4' CEILING i-3••-........... 1--·----10·-----+' 1' n ,§~ 4••----,..----il/,..-· "'",-.,.., .. 9· ... ,4••----.----.-------4• f f . I, 11' . 2 ' 11' ~"' "<i' 'J'c: 216~1 t,:;": • i':';'., ;.· 3•011xs O" SH ,,,, ,, ~;: 12'6" ,. -;i?. 1ji' 6." • TEMPERED GL, ,S 3'011XS'O" 2 ~I 4,.16'6" 13' S'O"X3'0'1 SL ft'- ,.......,,ATT=1c,_.-,··. \._'.Y ACCESS 22'X36" LIVING ROOM 9'3/4" CEILING j : ' ~ f SH DN ';' 18 RISERS /· 3,6, KITCHEN tf' -r 9'3/4" CEILINl'G-J=F:fi4.--.Jlu 3•oux31611 SL .TEMPERED GLASS r------_ K ~--s1611 -f<'!--..... l-'-::---6' 'f'-, i--, /G\ l"iECK --4'6" ~ '21'. ~ TEMPERED GLASS - -------r--. I ' . 1+-4•--------111611-+--------6'6"---i 1+-----11'6"------------10·6"-------1~ l+--'----------20·------------<,i"""--------~-----:22·-------------PJ ,.._ _______________________ 42''----,-'---------------------,.., 2ND -FL HOUSE 1 ' .. LIVING AREA=-------- 924.00 ft' 2ND DEWILLING UNIT I 51' DOUBLE TOP PLATE TO HAVE A 48" MIN. LAP SPLICE PROVIDE 8•16d L.AP SPICE NAILING MIN. CBC. 2308.9.2.1. THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTI:D BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: · 1] WATER CLOSET, GRAVITY TANK-TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX; 21 SHOWER HEAD= 2.0 GPM MAX. 3] KITCHEN FAUCETS= 1.S GPM M.AX. 4]LAVATORY FAUCETS= 1.2 GPM MAX. 5] URINALS .5 GALLONS PER FLUSH ] IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VAL YES MUST BE PRESSIJRE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENTVACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. FIRE STOPS AT THE FOLLOWING LOCATIONS PER CBC 70S. IN CONCEALED SPACES.OF STUD WALLS AND PARTmoNs, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10' FOOT INTERVALS ALONG THE LENGTH Of THE WALL; B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS; C. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OFTHE RUN AND BETWEEN STUDS ALONG AND INLINE WITH THE RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED; AND D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS WHiCH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS. E. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY-BUlLT CHIMNEYS. PRIOR TO CONSTRUCTION THE FRAMING CONTRACTOR AND THE HEATING CONTRACTOR ARE TO DETERMINE WHERE THE HEATING DUCTS, RETURN AIR, ECT. ARE TO GO. EXTERIOR WINDOWS, WINDOW WALLS, GLAZED DOORS. AND GLAZED OPENING WITHIN DOORS SHALL BE DUAL-GLAZED UNITS WITH A MINIMUM OF ONE TEMPERED PANE, OR SHALL BE GLASS BLOCK UNITS. OR, SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 20 MINUTES. GLAZING FRAMES MADE OF VINYL SHALL HAVE WELDED CORNERS AND METAL REINFORCEMENT IN THE INTERLOCK AREA. PROVIDE NOTE ON ELEVATION SHEET AND WINDOW SCHEDIJLE. SPECIFY FRAME MATERIAL AND AN APPROVED MANUFACTURE OR PROVIDE MANUFACTURES INFO DOWMENTING COMPLIANCE. ALL EXTERIOR WALLS TO BE 2X6 STUDS @ 16" O.C. UNLESS NOTED OTHERWISE SANYO HEAT PUMP #24KS72/24KLS72 SEER=20 EER=11.7 BTU= H 24,200 = C 24,200 --.,DOOR UNIT W= 41-15/16" H= 1.1-23/32" D 8-19/32" W=26.5LBS OUTDOORUNIT Wa:35-7/17" H=29-1/8" D= 12-7/16"W=97.0LBS 638.00 ft' 60.00 ft' DECKS PORCHES------ LIVING AREA-_______ _ DECKS PORCHES 57.50 ft' 2ND Fl OOR PLAN SCALE 1/4" = 1'0" RONS II IIUlll Iii 11111m11 FLOOR PLAN LEGEND NEW FULL HEIGHT WALLS EXISTING FULL HEIGHT WALLS WINDOW, SLIDING, GLASS DOOR OR MIRROR DOOR SHELF AND POLE K\\',\',j HANDRAIL OR PARTIAL WALL ...----, HEADER OR WALL OPENINGS ~ RETAINING WALLS HOUSE PLANS WNERSNAME JESSE SMITH (760) 724-4159 DRAWN BY: RTL #2862 OWNERS PHONE# (760) 504-8987 DRAWING NUMBER 4 OF 9 ROOFING SHALL HAVE A MINIMUM CLASS "A" RATING ALL ROOFING MATERIALS TO BE APPLIED AS PER MANUFACTURES SPECIFICATIONS All FLASHING, WATERPROOFING, UNDRLA YMENTS, ECT. TO BE APPLIED AS PER MANUFACTURES SPECIFICATIONS AND TO CODE. 2'0" MIN. CHIMNEY TO ROOF CLEARANCE FOR A 10.0" RADIUS ABOUT THE CHIMNEY, ALSO CHECK WITH MANUFACTURE TO SEE WHAT IS THE MIN. & MAX. OPERATING HEIGHT TRUSSES TO 1-IAVE A 2XG (OPTIONAL)TOP CHORD 1 /2" CLEARANCE BETWEEN TRUSSES AND NON-BEARING WALLS AND USE TRUSS CLIPS AT All PERPENDICULAR PARTITTON WALLS CONTRACTOR TO CHECK ALL MEASUREMENTS IN THE FIELD PRIOR TO ORDERING TRUSSES 2" x RIDGE BLOCKING FOR DIAPHRAGM NAILING. "EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE FOLLOWING INFORMATION LOCATED WITHIN 2 FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD: A)IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS.B)THE DESIGN LOAD. C)THE SPACING OF THE TRUSSES." EXPOSED VALLEY FLASHINGS SHALL BE AT LEAST NO. 26-GUAGE CORROSION-RESISTANT METAL INSTALLED OVER A MINIMUM 36" WIDE UNDERLAYMENT CONSISTING OF ONE NO. 72 ASTM CAP SHEET RUNNING THE FULL LENGTH OF THE VALLEY. . ' 2'' 18' I ' I' 51' ------------------------42•,-----------------------~ "'---------1s'611 _______ _..,_'"".-4'6" _ _, __ 1---s•s .. ----,·----------1s•st1---'------..i 6 8 P, 4' . !I r~---- 1 >---+------< I L ---- L:4 S' 6 8 • L 121 11' 1 ' 3'6" 11' l=S'G' : ' • • 51' 11 9' r,: , "'SX6 I 29' ALL EXTERIOR Wt LLS TO BE 2X6 STUDS @ 16" O.C. UNLES~ NOTED OTHERWISE 21611 161611 . 3'6" 1 ' V SLOPE DECK 1/4"T012" ' -----~---- ATTIC ACCESS 22"X36" .· 6 8 . . I I /\ /\ '' /1\ ~ /1\~ s1s11--!s;>H~-1---.G•-=-......i ' l-5' ' DE< K l=4'6" ; ~ r-.. "'-_'\ ... ' .,.....,...._...._...._ .... ,,_ . . . ------11'6"-----..... -----10'6"-----i 1+----'----.;_--20·----------...... +:.-----------22·------·------..i SOLID SHEATH ENTIRE EXTERIOR OF BUILDING WITH 3/8" PLYWOOD {C-D,C-C,OR STRUCT.111 NAILED WITH 8d @6" o.c. B.N. Ai;· o.c. F.N. EXCEPT WHERE V ~CURS ALL SHEAR WALLS TO EXTEND TO THE ROOF . . . FOR SIMPSON STRONG WALL SHEARWALLS SEE MANUFACTURES SPECIFICATIONS. -------------~----'--------42•----------------------~. SCALE 1/411 =1 1011 . COOL ROOF REQUIRED 2 ' ' l-=1 I . 1 ' " . FUTURE SOLAR PHOTOVOLTAIC MIN. 250 SQ.FT. 3' FROM HIPS AND VALLEYS 3' FROM RIDGE MIN. 80 SQ. FT. & 5' DIMENSIONS FROM ANY HIGH OBSTRUCTIONS MIN. 2X THE HEIGHT OF THE OBSTRUCTION BRACING 3\8" PLYWOOD STRUT. II SHEAR PANEL 6 NAILED WITH 8d @ 4" 0.C. B.N.& F.N. 12" O.C. F.N. WITH A STHD10 ON A 4X4POST [MINI @ EA. END [NO STHD10 WHERE CB'S OCCUR} & 1 X6 LET IN BRACES FROM ENDS AND EVERY 4 25' UNLESS OUTHERWISE NOTED ~ 2X4 DIAG. BRACES 10'0"LONG MIN. CUT INTO THE TOP PLATE; PITCH 12 ROOF COVERING: ELK PREMIUM ROOFING FIBERGLASS SHINGLES OVER 1 LAYERS 30# FELT ESR-1475 INSTALLED AS PER MANUFACTURES · SPECIFICATIONS TIMBERLINE COOL SERIES -BARKWOOD INITIAL SOLARREFLECTANCE = 0.27 THERMAL EMITTANCE= 0.92 SOLAR REFLECTANCE INDEX (SRI)= 29 LEED® CREDITS =YES CRRC # 0676-0041 ROOF SHEATHING: 1/2" WOOD STRUCTURAL PANEL P II 24/0 NAILED C-D UNBLOCKED W I 8d COMMON@ 6" 0.C. E.N. & 12" O.C. F.N. & !EXTERIOR GRADE ON ALL OVERHANG OVERHANGS: ALL OVERHANGS TO BE 2'0" EXCEPT 1 'O" ON THE GABLE ENOS AND TOWERS AND BAYS SHADED AREAS TO BE CALIF. FILL DECK COVERING DEX-0-TEX AS PER MANUF. SPECS. ICC# ESR-1757 SHEATHING: 2X6 T&G RONS HOUSE PLANS SCALE: 1/4"=1'0' CONTRACTOR: DATE: 4-12-18 OWNERS NAME JESSE SMITH (760) 724-41 59 DRAWN BY: RTL #2862 OWNERS PHONE# (760) 504-8987 DRAWING NUMBER 5 OF 9 ----- 1 ST F.L. C.J. & 2ND F.L D,J, 2X14@16"0.C," . ' 1ST F.L. C.J. & 2ND F.L. D.J. 2X14@1f0,C." / . ... -----------------------42•--'--.--'------,,,,_f-..... ---------------1·~ / I c?.'!o(;,t~ . 6: B f"-,. l--+-'-1--lot-,_ ....... 1, 6 i+------,.,C-,.-f--'---22·--------,-----+1 . / I 1ST F.L. C .• & 2ND F.L. D.J. 2X14@16'1).C." • . 0 BE P ACED AT OWNERS l'\PPROVAL ['JOT TO ~E IN THE BUJLDIN( SETBACKS •o BE Pl !ACED AT OWNERS i'.PPROVAL OT TO E IN THE BUILDING SETBACKS . I '--------'-H • 1 ' . 5'1' 29' SOLID SHEATH ENTIRE EXTERIOR OF BUILDING WITH 3/8" PLYWOOD [C·D,C-C,OR STRUCT.11] NAILED WITH 8d @6" O.C .. B.N.J\. 1~ 2;".0,C. F.N. EXCEPT WHERE V ~CURS I ' ALLSHEAR WALLS TO EXTEND TO THE ROOF · j\ FOR SIMPSON STRONG WALL SHEARWALLS ~ SEE MANUFACTURES SPECIFICATIONS 6X1 -1ST F.L. C.J., 2ND F.L. D.J. 2X1 4@16"0.I ." 161611 1 7' 3'6" SW18X9X6 ' 6X12 CONT!NWOUS HOR S 18X9X6 66 . ---6) -----,........ "-j L---1~ ----- 1 ST F.l C.J. & 2ND F.L. D.J. 2X14@ 6"0.C." ~ 6'12 1STF.L. C . & 2NO F,L. D.J. 2X14@16' b.C." . .ov '··<._. -: b)i'tlt<:~•f..'·':-, ,-'.:A!f,· '" -6 8 xa : ' 2 ,' ' . I 3' ,11 11' L=SfQI 1 ST F.L.C ii. & 2ND F.L. D.J. 2X14@16 O,C," 2 ,. ,51' TO BE P:.ACED AT OWNERS APPROVAL NOT TO llE IN THE BUILDIN• SETBACKS I /_ \ ' /1 \ I =4'6" '11 I/ 1 \=4'o" r.==:::;;4:;',--.i.---s· --4'611 91 /,\ 1~4'0" I l l+---'--------20·-----'--------+1 I I l_ ___ -'-t\ _____________ r~----TOP FLOOR DEC CANTILEVER \ 22··------------+! ,._-----------------------.42•---------',t--------------~ .FOR THE CAN~RVERED DECK NOTCH THE JOIST 4" AND TRIM FOR SLOPE. SCALE 1/4" = 1'0" DBL JOIST @ ALL PARALLEL PARTITIONS DBL BLOCK@ ALL PERPENDICULAR · PARTITIONS ALL EXTERIOR WALLS TO BE 2X6 STUDS @ 16" O.C. UNLESS NOTED OTHERWISE RONS HOUSE PLANS SCAtE: 1/411=11011 DATE: 4-12·18 OWNERS NAME JESSE SMITH CONTRACTOR: (760) 724-4159 DRAWN BY: RTL #2862 OWNERS PHONE# (760) 504-8987 DRAWING NUMBER 6 OF 12 r+--------,--------,-----------,42i-----------'-------------'----... --------1s1611 _______ ..., __ 41611-----s•s0 -----------161-6u---------;..J 51' ' ' 2 ' L=4' 2 ' '10 STEM WALL WHERE GARAG DOORS :>R EXTERIOR MAN DOORS OCC UR ADJUST STEM WALL HEIGHT FC R THE GARAGE DOOR AND HEAD R HEIGHT AND THE STRONG WAL S 13•---------3•- l 161611 I I ' I I I SW18X9X6 ~ i SW-......_ 7 ---r--- /\ 7\ =4'6" II /,\ L~4'0" / 1 \=4•0• / 1 \ I ! \ f._i==:;;4~• -...l.---5•·--.... ---41611 ~·--~.J.r-=::-;4;:, =.J· I I -------~---20•-----------+1 I I I I"" -TOP FLOOR DECI CANTILEVER SOLID SHEATH ENTIRI: EXTERIOR OF BUILDING WITH 3/8" PLYWOOD [C-D,C-C,OR STRUCT.11] NAILED WITH 8d ®_6" O.C._B.N. xi; O.C. F.N, EXCEPT WHERE V ~CURS ALL SHEAR WALLS TO EXTEND TO THE ROOF j\ FOR SIMPSON STRONG WALL SHEARWALLS ~ SEE MANUFACTURES SPECIFICATIONS L---~------~---~----1 "'--------'-----'---2:?•-'--'·-----------,-.1 ... ------------------------.. -42•------.--------------'-' ----. FOi JNDAIION Pl AN * ALL CONCRETE TO BE DONE IN A MONOLITHIC POUR * SEE SIMPSON CATALOG FOR INSTALLATION OF All HOLDDOWNS · * MINIMUM DISTANCE FROM FOUNDATION TO DAYLIGHT TO BE H/3 OR 7'0" WHICHEVER IS GREATER. * CONTRACTOR TO CHECK FOR CORRECT PLACEMENT OF ALL HOLDDOWNS & CORRECT POST CONNECTORS *CONTRACTOR TO COMPLY WITH ALL THE SOIL REPORT RECOMMENDATIONS --------------------------------- SCALE 1/4" =1'0" * INSPECTOR Will RECHECK FOR EXPANSIVE · SOIL OR GRADING REQUIREMENTS AT FIRST INSPECTION. * CONTRACTOR TO CHECK WITH AN ENGINEER FOR STRUCTURAL INTEGRITY AND LOCAL CODES PRIOR TO PLACEMENT OF CONCRETE * ALL HOLODOWNS MUST BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION "O BE P ~CED AT OWNERS ~PPROVAL OT TO ~ IN THE BUILDIN~ SETBACKS . ' 2 ' 11' 51' TO BE P .ACED AT OWNERS APPROVAL NOT TO BE IN THE BUILDINI SETBACKS RONS HOUSE PLANS SCALE: 1/4"=1'0" CONTRACTOR: DATE: 4-12-18 OWNERS NAME JESSE SMITH (760) 724-4159 ORAWN BY: RTL #2862 OWNERS PHONE# (760} 504-8987 -------- DRAWING NUMBER 7 OF 12 TELEVISION, PHONE & TELEPHONE OUTLETS IN EVERY ROOM CHECK WITH OWNER FOR PLACEMENT FIXED · FIXED 0000 * ALL BATHROOMS AND KITCHENS TO HAVE FLUORESCENT [40 WMENS PER WATTOR GREATER] GENERAL LIGHTING PER CEC, TITLE 24 FIXTURES MUST BE OF THE BALLASTED TYPE THAT CAN ONLY ACCEPT FLUORESCENT BULBS. ALL ELECTRICAL WORK TO BE DONE AS PER CEC. *SMOKE DETECTOR TO BE PERMANENTLY WIRED IN WITH A BATTERY BACKUP. SMOKE DETECTORS TO BE LOCATED CENTRALLY IN CORRIDOR OR AREA GIVING ACCESS TO SLEEPING ROOMS. WHEN SLEEPING ROOMS ARE UPSTAIRS, AT THE UPPER LEVEL IN CLOSE PROXIMITY TO THE ST AIR. IN ROOMS ADJACENT TO HALLWAYS SERVING BEDROOMS, WHEN SUCH ROOMS HAVE A CEILING HEIGHT 24 INCHES OR MORE ABOVE THE CEILING HEIGHT IN THE HALLWAY. SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE UNIT CBC 907.2.10.1.2 ALL GARAGE CIRCUITS TO TO BE NO LESS THAN 20 AMP. ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND THE NUMBER OF RECESSED CAN LIGHTS *BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY A MINIMUM OF ONE 20"AMPERE BRANCH CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM *ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC * ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITHCEC. *LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC. *LIGHTING FIXTURES INSTALLED IN CLOTHES CLOSETS SHALL COMPLY WITH CEC. ALL BEDROOMS TO BE ON A MINIMUM OF TWO SEPARATE CIRCUITS WITH NO LESS THAN 20 AMP. EACH ALL BEDROOM BRANCH CIRCUITS WILL BE ARC FAULT CIRCUIT PROTECTED. PER CEC. ELECTRICAL BOXES LOCATED IN FIRE RESISTIVE ASSEMBLIES MUST BE HORIZONTALLY SEPARATED BY NOT LESS THAN 24" ELECTRICAL BOXES LOCATED IN FIRE RESISTIVE ASSEMBLY MUSf BE LISfED FOR THE RATING OF THE ASSEMBLY. I illllilill] EXH. FAN PROVIOING TEN AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPT ABLE DISCHARGE POINT FOR EXHAUST AIR TO BE AT LEAST 3 FEET FROM ANY OPENING WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUlLDING NUTONE #ZN11 OHL OUCT AS PR MANUFACTURES SPEC. 110 CEM ENERGY ST AR RA TED ULTRA GREEN W/· HUMIDISTAT & MOTION SENSING SOUND RA TING 0.3 SONES UL APPROVED FOR OVER TUBS OR .SHOWERS WPGFCI S10"X4'0" SL TRY Cl "§:: AFCI I I I I I I AFC! PORCH 110V SMOKE DET. PERMANENTLY WIRED . IN W /BATT.BACK UP & CARBON MONOXIDE ALARM I WIIGFCI I I WATER HEATER T ANKLESS RHEEM RT<,: 7 4 XN' 1 W14'7/8"X Dl 1·1 /8" X H25-3/8" MIN. 12" ABOVE GROUND ENERGY FACT R .82 ALL ELECTRICAL WORK TO BE DONE AS PER CEC. ALL CFCI OUTLETS TO BE DOUBLE PROTECTED WITH AFCI ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1,000, AND APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWEWNG UNITS THAT AND IN SLEEPING UNITS WITHIN WHICH FUEL ·BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES SHALL BE PROVIDED WITH A cARBON MONOXIDE ALARM ALLELECTRI ALL CFC! 0 OUTLETS SPECIFIED IN CEC SHALL BE TAMPER RESISTANT ETS TO BE DOUBLE A. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. CARBON MONOXIDE ALARMS REQUIRED BY THE CEC AND SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS. q:r GFCI AFCI 6'0"X61811 MIRROR DOOR 61011X6T8II MIRROR DOOR ASTER SUITE BEDROOM #2 AFCI AFCI AFC! . AFC!. AFC! AFCI AFCI AFCI GFCI ALL GARAGE OlITLETS TO ----.. BE G.F.C.I. PROTECTED DISCONNE B. OUT.SIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM[S] C. ON EVERY LEVEL OF A DWELLING UNIT INCWDING BASEMENTS. D. WHERE MORE THAT ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT THE ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. 8 TO PLACED AT OWNERS APPROVAL NOT O BE IN THE BUILDING SETBACKS E. CRC MULTIPLE-PURPOSE ALARMS, CARBON MONOXIDE ALARMS COMBINED WITH SMOKE ALARMS SHALL COMPLY WITH ALL APPLICABLE STANDARDS, AND REQUIREMENTS FOR LISTING AND APPROVAL BY THE OFFICE OF THE STATE FIRE MARSHALL FOR SMOKE ALARMS. CEO AT OWNERS APPROVAL BE IN THE BUILDING SETBACKS NOTE: PER THE 2016 CEC ELECTRICAL CODE ARTICLE 210.12 ARC-FAULT CIRCUIT-INTERRUPTER . . . . DISCONNECT PROTECTION IS REQUIRED IN ALL. 1 20.VOL T, SINGLE PHASE, 1 5-AND 20-AMPERE BRANCH CIRCUITS SUPPL YING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, PARLORS, UBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS. 5'011X4'011 SL TELEVISION, PHONE & TELEPHONE OUTLETS IN EVERY ROOM CHECK WITH OWNER FOR PLACEMENT ALL APPLIANCES TO HAVE SEPARATE DEDICATED CIRCUITS AND SIZED ACCORDING TO THE APPLIANCE SPECIFICATIONS SUCH AS, REFG •. , DISHWASHER, TRASH COMPACTOR, GARBAGE DISP., OVEN, RANGE, MICROWAVE, FAU., AIR COND., VAC., ECT. THE ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND NUMBER OF TELEVISION, TELEPHONE, & INTERCOM OUTLETS. HIGH EFFICACY LUMINARIES OTHER THAN OUTDOOR HID: CONTAIN ONLY HIGH EFFICACY LAMPS AS OUTLINED IN TABLE 150-C, AND DO NOT CONTAIN A MEDIUM BASE SCREW SOCKET[E24/E26]. BALLASTS FOR LAMPS 13 WATTS OR GREATER ARE ELECTRIC AND HAVE OUTPUT FREQUENCY NO LESS THAN 20 kHz •• HIGH EFFICACY LUMINARIES -OUTDOOR HID: CONTAIN ONLY HIGH EFFICACY LAMPS AS OUTLINED IN TABLE 150-C, LUMINAIRE HAS FACTORY INSTALLED HID BALLAST. OCCUPANT SENSORS: SHALL COMPLY WITH SECTION 119[0] AND SHALL NOT TURN ON AUTOMATICALLY OR HAVE AN ALWAYS ON OPTION. LUMINAIRES THAT ARE RECESSED IN INSULATED CEILINGS ARE APPROVED FOR ZERO CLEARANCE INSULATION COVER [IC] AND ARE CERTIFIED TO ASTM E283 AND LABELED AS AIR TIGHT [ AT l TO LESS THAN 2.0 CFM AT 78 PASCALS I I REQUIRED TO ACCOMMODATE FUTURE INSTALLATION OF ROOF-MOUNTED SOLAR PHOTOVOLTAIC SYSTEM: * APPROVED MINIMUM 4-INCH SQUARE ELECTRICAL JUNCTION BOX LOCATED WffillN 72 INCHES HORIZONTALLY AND 12 INCHES VERTICALLY ·oF MAIN ELECTRICAL SERVICE PANEL * MINIMUM 1-INCH-DIAMETER LISTED ELECTRICAL METALLIC ELECTRICAL PLAN LEGEND '-7---------------9'0"X7'0" SECTIONAL STEEL IN SULA TED DOOR GARAGE RACEWAY ORIGINATING AT READILY ACCESSIBLE ATTIC LOCATION WITH PROXIMITY TO SOLAR ZONE AREA AND TERMINATING AT THE REQUIRED ELECTRICAL JUNCTJON BOX MANDATORY (CBEES 150.0(K) A} BATHROOMS: LIGHTING FIXTLRES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE THE FOLLOWING: · AT LEAST ONE HIGH-EFFICACY FIXTURE SHALL BE INSTALLED IN EACH BATHROOM. ALL OTHER BATHROOM LIGHTING SHALL BE HlGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR. B} GARAGES, LAUNDRY ROOMS , AND UTILITY ROOMS: LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR PR UTILITY PLANS SHALL DEMONSTRATE ALL LlGHTING IS HIGH EFFICACY AND CONTROLLED E!Y A VACANCY ·SENSOR C) ROOMS OTHER THAN KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, OR UTILITY ROOMS: LIGHTING FIXTLRES AND WITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIG!:l EFFICACY OR CONTROLLED BY EITHER A VACANCY SENSOR OR DINNER. D} OUTDOOR LIGHTING: LIGHTING FIXTURES AND SWITCHES . SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING 15 HIGH EFFICACY EXCEPTION : LOW-EFFICACY LIGHTING CONTROLLED BY A MOTION SENSOR AND EITHER A PHOTO CELL OR ASTRONOMICAL TIME CLOCK TOPDECKUNE VACANCY SENSOR SWITCH TO BE USED IN GARAGES, . SERVICE, AND LAUNDRYS •. BRANCH CIRCUITS FOR ALL ROOMS (EXCEPT KITCHEN, BATHROOMS, & GARAGE) WIU. BE ARC FAULT CIRCUIT PROTECT PER [CEC 210.12] * CONVENIENCE OUTLETS IN BATHROOMS, KITCHEN COUNTER TOPS, OUTDOORS,AND IN GARAGES AND BASEMENTS [ OTHER THAN FOR LAUNDRY AND SIMILAREQUIPMENT] SHALL BE GFICPROTECTED., ART. 210-8 *ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC .210-B ALL WIRING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE. ALL APPLIANCES TO BE INSTALLED AS PER MANUFACTURES SPECS. . . ALL APPLIANCES TO HAVE SEPARATE OEDICATED CIRCUITS AND SIZED ACCORDING TO THE APPLIANCE SPECIFICATIONS SUCH AS , REFG., DISHWASHER, TRASH COMPACTOR, GARBAGE DISP., OVEN, RANGE, MICROWAVE, FAU., AIR COND., VAC., ECT. THE ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND NUMBER OF TELEVISION, TELEPHONE, & INTERCOM OUTLETS. . PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP,PER SECTION R314: A} SUCH SMOKE ALARM LOCATIONS SHALL COMPLY WITH THE FOLLOWING: 1 THEY SHALL BE NOT LESS THAN. 3' FROM THE DOOR OPENING OF A BATHROOM. GFCl WATER HEATER TANKLESS RHEEM . RTG-74XN-1 ., W14-7/8"XD11-1/8" * MINIMUM 1-INCH-DIAMETER. LISTED ELECTRICAL METALLIC RACEWAY ORIGINATING AT THE REQUIRED ELECTRICAL JUNCTION BOX AND TERMINATING AT THE MAIN ELECTRICAL SERVICE PANEL * NOT ELECTRICAL JUNCTION BOX AND SEGMENT OF METALLIC RACEWAY IN THE ATTIC SHALL BE PERMANENTLY AND VISIBLE MARKED AS "FOR FUTURE SOLAR PHOTOVOLTAIC' 2 THEY SHALL BE AT LEAST 20' FROM A COOKING APPUANCE. THEY SHALLBE AT LEAST 3' FROM SUPPLY REGISTERS OF HEATING / COOLING SYSTEMS 3 THEY SHALL BE AT LEAST 3' FROM THE TIP OF THE BLADE OF A CEILING MOUNTED FAN '; ~ X H25-3/8" MIN. 12" GFCl•,,·:'!<f,%':"7<:l.;,(W;,;.·, '.<,~,·~;; ,,,,,;;,,noc:GF~i''',·>'··>"'""·' ;:1---1 ;r " ALL GARAGE OUTLETS TO ;c THE MAIN ELECTRICAL SERVICE PANEL SHALL INCLUDE RESERVED SPACE ALLOWING FOR.INSTALLATION OF A CIRCUIT BREAKER FOR FUTURE ELECTRIC VEHICLE CHARGING SYSTEM. THE RE.SERVED SPACE SHALL BE PERMANENTLY AND VISIBLE MARKED AS "EV CAPABLE" ALL OF THE FOLLOWING ARE REQUIRED TO ACCOMMODATE FUTURE INSTALLATION OF AN ELECTRIC VEHlCLE CHARGING SYSTEM: 9'0"XTO" SE NAL STEEL ~ru~~ GFCI I I ! I ! BE G.F .C.I. PROTECTED GARAGE I I GFCI 220V GFCI DISCON CT GFCI * APPROVED MINIMUM 41 NCH SQUARE ELECTRICAL JUNCTION BOX LOCATED ON THE INTERIOR OF THE GARAGE AT A MINIMUM 30 INCHES AND MAXIMUM 48 INCHES ABOVE THE GARAGE FLOOR. *MINIMUM 1 INCH DIAMETERLISTED ELECTmCAL METALLIC RACEWAY ORIGINATING AT THE MAIN ELECTRICAL SERVICE PANEL AND TERMINATING AT THE REQUIRED ELECTRICAL JUNCTION BOX. * ELECTRICAL JUNCTION BOX SHALL BE PERMANENTLY AND VISIBLE MARKED AS . " FOR FUTURE ELECTRIC VEHICLE CHARGING" TO.BE PLACED AT OWNERS APPROVAL NOT TO BE IN THE BUILDING SETBACKS 200 AMP. METER I r---TOP FLOOR DECK CANTILEVER ·'--------------------1 PANEL AND SERVICE ENTRANCE, LECTRICAL CONTRACTOR TO CHECK AND VERIFY WITH OWNER THE SIZE LOCATION AND TO NEWLY CONSTRUCTED GARAGES WITH ELECTRICAL SERVICE SHALL COMPLY WITH THE FOLLOWING ELECTmC VEHICLE-READY MEASURES (COUNTY BLIILDING CODE 92.1.3112, COUNTY BUILDING CODE 92.2.R332, CALGREEN 4.106.4.1 ): EXCEPTION: NEWLY CONSTRUCTED GARAGES ON LOTS WITH AN EXISTING GARAGE INCLUDING EITHER AN ELECTRIC VEHICLE CHARGING SYSTEM OR ELECTRICAL CONDUIT INSTALLED PER COUNTY BUILDING CODE 92.1.3112.4. 1 THROUGH 92.1.3112.4.3 TO ACCOMMODATE FUTURE.INSTALLATION OF AN ELECTRIC VEHICLE CHARGING SYSTEM A. MANDATORY: -NOTE ON FLOOR PLAN .QR UTILITY PLAN: "THE MAIN ELECTRICAL SERVICE PANEL SHALL INCLUDE RESERVED SPACE ALLOWING FOR INST ALLA Tl ON OF A CIRCUIT BREAKER FOR A FUTURE ELECTRIC VEHIQE CHARGII-IG SYSTEM. THE RESERVED SPACE SHALL BE PERMANENTLY AND VISlBLY MARKED AS 'EV CAPABLE.'" • INDICATE ON FLOOR PLAN OR UTILITY PLAN ALL OF THE FOLLOWING TO ACCOMMODATE FUTURE INSTALLATION OF AN ELECTRIC VEHICLE CHARGING SYSTEM: APPROVED MINIMUM +INCH-SQUARE ELECTRICAL JUNCTION BOX LOCATED ON THE .INTERIOR OF THE GARAGE AT MINIMUM 30 INCHES ANO MAXIMUM 48 INCHES ABOVE THE GARAGE FLOOR •MINIMUM 1-INCH·DIAMETER LISTED ELECTRICAL METALLIC RACEWAY ORIGINATl~G AT THE MAIN ELECTRICAL SERVICE PANEL AND TERMINATING AT THE REQUIRED ELECTRICAL JUNCTION BOX NOTE ON PLANS: 'ELECTRICAL JUNCTION BOX SHALL BE PERMANENTLY AND VISIBLY MARKED AS 'FOR FUTURE ELECTRIC VEHICLE CHARGING.'" SCALE 1/4" = 1 '0" PLAN SEE IF IT NEEDS TO BE MOVED. SYSTEM GROUND TO BE AS PER CEC MIN. 30" WIDE BY 36" DEEP WORKSPACE IN FRONT OF ELECTRICAL PANELS. PANELS ARE TO BE LOCATED SO AS TO REDUCE TO A· MINIMUM THE PROBABILITY OF COMMUN!CATINGFIRE TO ADJACENT COMBUSTIBLE MATERIALS. PANELS ARE NOT PERMITTED IN BATHROOMS. ALL ROOMS AND OUTDOOR LIGHTING TO HAVE HIGH EFFICACY · LIGHT FIXTURES [ FLUORESCENT WITH GU24 SOCKETS ] NO MEDIUM BASE INCANDESCENT LAMP SOCKETS . ARE PERMITTED FOR HIGH EFACACY LIGHT FIXTURES . AN INTERMITTENTLY OR CONTINUOUSLY OPERATING LOCAL MECHANICAL EXHAUST SYSTEM [ WITH OUTDOOR AIR] SHALL BE INSTALLED IN EACH KITCHEN AND BATHROOM COMPLYING WITH ASHRAE STANDARD 62.2-2007 AS ADOPTED BY .THE CALIFORNIA ENERGY COMMISSION. INTERMITTENT LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 50 CFM IN BATHROOMS AND 100 CFM IN KITCHENS. CONTINUOUS LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 20 CFM IN BATHROOMS AND 5 ACH [AIR CHANGES/HOUR] fN KlTCHENS BASED ON KITCHEN VOLUME. q:r~ 110V ©=<tl> ELECTRIC OUTLETS 11 OV SMOKE DET. PERMANENTLY WIRED IN W /BATT.BACK UP WPGFCI WATERPROOF 11 OV ELECTRIC OUTLETS EXH. FAN PROVIDING TEN AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPT ABLE DISCHARGE POINT FOR EXHAUST AIR & CARBON MONOXIDE TO BE AT LEAST 3 FEET ALARM FROM ANY OPENING WHICH ALLOWS AIR AFCI · ARC FAULT CIRCUIT PROTECTED ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING NUTONE #ZN1.10HLDUCT AS PR MANUFACTURES SPEC. GFCI GROUND-FAULT CKT INTERRUPTER s SWITCH· F-S FLOURESCENT SWITCH 110 CFM ENERGY STAR RATED ULTRA GREEN W/ HUMIDISTAT vs VACANCY SENSOR SWITCH OSP SWITCH FOR PHOTO CONTROL & MOTION SENSING SOUND RA TING 0.3 SONES UL APPROVED FOR OVER TUBS OR SHOWERS W/ MOTION SENSOR D-S DIMMER SWITCH @:= 220V $ CAN LIGHT LED SPECIAL TY LIGHTING LIGHT FIXTURE FLOURESCENT W/BALLASTS LIGHTS TO HAVE EFFICIENCY OF INDUSTRIES ADJUST ABLE DOWN AT LEAST 40 LUMENS PER WATT LIGHT #1000 (1005-LEDZ•'H-927· APH-CZ14L T2-"*-*"*·**A · DISCONNECT 2016 ENERGY LIGHTING STANDARDS KITCHEN GARAGE, LAUNDRY ROOM, UTILITY ROOM BATHROOM OUTDOOR LIGHTING ATTACHED TO BUlLDINGS COMMON AREAS OF LOW RISE RESIDENTIAL BUILDINGS WITH 4 OR MORE DWELLING UNITS RESIDENTIAL PARKING LOTS AND GARAGES FOR 8 OR MORE VEHICLES . AT LEAST HALF THE INSTALLED WATTAGE OF LUMINARIES [ EXCEPT LIGHTING INTERNAL TO CABINETS] IN KITCHENS SHALL BE HIGH EFFICACY: LOW EFFICACY FIXTURES MUST BE SWITCHED SEPARATELY. LIGHTING INTERNAL TO CABINETS SHALL USE NO MORE THAN 20W OF POWER PER LINEAR FOOT OF ILLUMINATED CABINET. FIXTURES AND SWITCHES SHOWN ON FLOOR FOR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY AND CONTROLLED BY A VACANCY SENSOR BATHROOMS: LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE THE FOLLOWING: AT LEAST ONE HlGH-EFFICACY F!XlURE SHALL BE INSTALLED IN EACH BATHROOM. ALL OTHER BATHROOM LIGHTING SHALL BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR. LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY .PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY EXCEPTION : LOW-EFFICACY LIGHTING CONTROLLED BY A MOTION SENSOR AND EITHER A PHOTO CELL OR ASTRONOMICAL TIME CLOCK HIGH EFFICACY OR OCCUPANCY SENSOR MUST MEET NONRESIDENTIAL LIGHTING STANDARDS RONS HOUSE PLANS SCALE: 1/4'=1 '0" CONTRACTOR: DATE: 4'12-18 OWNERS NAME JESSE SMITH (760) 724-4159 DRAWN BY: RTL #2862 OWNERS PHONE# (760) 504-8987 DRAWING NUMBER 8 OF 12 A R-38 INSULATION R-21 INSULATION R-21 INS LATION 9'3/4" C !LING ION 5/8' DRYWALL. TYPEX -21 INS 11 N 10'3/ " CEILING TIONAL R-21 INSULATION 10'3"+0R· C !LING -------------------------i=.:=.=.=::.::.==_...:.:.:::.::... ________ 1.-____ __,_ • • TELEVlSION, PHONE & TELEPHONE OUTLETS IN EVERY ROOM CHECK WITH OWNER FOR PLACEMENT * ALL BATHROOMS AND KITCHENS TO HAVE FLUORESCENT [40 LUMENS PER WATTOR GREATER] GENERAL LIGHTING PER CEC, TITLE 24 FIXTURES MUST BE OF THE BALLASTED TYPE THAT CAN ONLY ACCEPT FLUORESCENT BULBS. ALL ELECTRICAL WORK TO BE DONE AS PER CEC. *SMOKE DETECTOR TO BE PERMANENTLY WIRED IN WITH A BATTERY BACKUP. SMOKE DETECTORS TO BE LOCATED CENTRALLY IN CORRIDOR OR AREA GIVING ACCESS TO SLEEPING ROOMS. WHEN SLEEPING ROOMS ARE UPSTAIRS, AT THE UPPER LEVEL IN CLOSE PROXIMITY TO THE ST AIR. IN ROOMS ADJACENT TO HALLWAYS SERVING BEDROOMS, WHEN SUCH ROOMS HAVE A CEILING HEIGHT 24 INCHES OR MORE ABOVE THE CEILING HEIGHT IN THE HALLWAY. SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE UNIT CBC 907.2. 1 O. 1.2 ALL GARAGE CIRCUITS TO TO BE NO LESS THAN 20 AMP. ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND THE NUMBER OF RECESSED CAN LIGHTS *BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY A MINIMUM OF ONE 20-AMPERE BRANCH CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM *ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC * ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC. *LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC. *LIGHTING FIXTURES INSTALLED IN CLOTHES CLOSETS SHALL COMPLY WITH CEC. ALL BEDROOMS TO BE ON A MINIMUM. OF TWO SEPARATE CIRCUITS WITH NO LESSTHAN 20 AMP. EACH ALL BEDROOM BRANCH CIRCUITS WlLL BE ARC FAULT CIRCUIT PROTECTED. PER CEC. ELECTRICAL BOXES LOCATED IN FIRE RESISTIVE ASSEMBllES MUST BE HORIZONTALLY SEPARATED BY NOT LESS THAN 24" ELECTRICAL BOXES LOCATED IN FIRE RESISTIVE ASSEMBLY MUST BE LISTED FOR THE RATING OF THE ASSEMBLY. E 1 1 I.A.Q. HOUSE FAN FAN MODEL1YPE: AIR KING MODEL AK80LS-1 ENERGY STAR 80 CFM@ LO SONE 4" DIAMETER SMOOTH WALL G.S. DUCT. LOCATE IN ATTIC THRU ROOF TO OUTSIDE AIR. MAXIMUM ALLOWABLE DUCT LENGTH 35 FEET. (PER ASHRAE 62.2 .TABLE 7.1) AFCI 1. •• PLAY ROOM EXH. FAN PROVIDING TEN 2·o••x4•011 SH 3'611)(31011 SL 3'011x1 1011 SL · AFOAFCI 5'0"X4'011 .SL 6'0"X61811 MIRROR DOOR BEDROOM#3 AFCI i=;;;;;:IU!,,,,v~-$- "'l . BEDR60M #4 6'011X61811 MIRROR DOOR AFC! AFCI AFCI AFCI AFCI AFCI " AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPT ABLE DISCHARGE ", ., '<"11.,:,·,, • •.'i:; :;~":/:,.;~-;;y!'·~i;;'.•:r: POINT FOR EXHAUST AIR TO BE AT LEAST 3 FEET FROM ANY OPENING WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING Nl/TONE #ZN11 OHL DUCT AS PR MANUF ACTIJRES SPEC. 110 CFM ENERGY ST AR RA TED ULTRA GREEN W/ HUMIDISTAT ATTIC 22'X36' & MOTION SENSING SOUND RATING 0.3 SONES UL APPROVED FOR OVER TUBS OR SHOWERS 5'0"X3'0" LI ING ROO VACANCY SENSOR SWITCH TO BE USED IN GARAGES, SERVICE, AND LAUNDRYS. l.A.Q. HOUSE FAN SL ' :(~::: AFCI FAN MODEL TYPE: AIR KING MODELAKBOLS-l ENERGY STAR 80 CFM@ 1.0 SONE BRANCH OROJITS f'OR ALL ROOMS (EXCEPT KITCHEN, BATHROOMS, & GARAGE) WILL BE ARC FAULT 4" DIAMETER SMOOTH WALl G.S .. DUCT. LOCATE IN ATTIC . THRU ROOF TO OUTSIDE AIR. MAXIMUM ALLOWABLE DUCT LENGTH 35 FEET. (PER ASHRAE 62.2 TABLE 7.1) CIRCUIT PROTECT PER [CEC 210.12] * CONVENIENCE OUTLETS IN BATHROOMS, KITCHEN COUNTER TOPS; OUTDOORS,AND IN GARAGES AND BASEMENTS [ OTHER THAN FOR LAUNDRY AND SIMILAR EQUIPMENT] SHALL BE GFIC PROTECTED., ART. 210-8 *ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CEC 21 0-8 ALL WIRING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE. ALL APPLIANCES TO BE INSTALLED AS PER MANUFACTURES SPECS. PERMANENTLY WIRED SMOKE ALARMS WITH BAmRY BACKUP,PER SECTION R314: A) SUCH SMOKE ALARM LOCATIONS SHALL COMPLY WITH THE FOLLOWING: 1 THEY SHALL BE NOT LESS THAN 3' FROM THE DOOR OPENING OF A BA TH ROOM. 2 THEY SHALL BE AT.LEAST 20' FROM A COOKING APPLIANCE. THEY SHALL BE AT LEAST 3' FROM SUPPLY REGISTERS OF HEATING/ COOUNG SYSTEMS 3 THEY SHALL BE AT LEAST 3' FROM THE TIP OF THE BLADE OF A CEIUNG MOUNTED FAN 411 DUCT 6' TO ROOF DECK · · ALL ROOMS AND OUTDOOR LIGHTING WPGFCI ALL APPLIANCES TO HAVE SEPARATE DEDICATED CIRCUITS AND SIZED ACCORDINGTO THE APPLIANCE SPECIFICATIONS SUCH AS, REFG., DISHWASHER, TRASH COMPACTOR, GARBAGE DISP., OVEN, RANGE, MICROWAVE, FAU., AIR COND .• , . VAC., ECT. THE ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND NUMBER OF TELEVISION, TELEPHONE, TO HAVE HIGH EFFICACY LIGHT FIXTURES [ FWORESCENT WITH GU24 SOCKETS ] & INTERCOM OUTLETS. NO MEDIUM BASE INCANDESCENT LAMP SOCKETS ARE PERMITTED FOR HIGH EFFICACY LIGHT FIXTURES 2ND FL ELECTRICAL Pl AN SCALE 1 /4" = 1 '0" . DN 18 !SERS ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1 ,000, AND APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS THAT AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM A. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. CARBON MONOXIDE ALARMS REQUIRED BY THE CEC AND SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS. B. OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREAJN THE IMMEDIATE VICINITY OF THE BEDROOM[S] . C. ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. D. WHERE MORE THAT ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING. UNIT 0~ WITHI.N A SLEEPING UNIT THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT THE ACTIVATION OF ONE ALARM $HALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. E. CRC MULTIPLE-PURPOSE ALARMS, CARBON MONOXIDE ALARMS COMBINED WITH SMOKE ALARMS SHALL COMPLY WITH ALL APPLICABLE STANDARDS, AND REQUIREMENTS FOR LISTING AND APPROVAL BY THE OFFICE OF THE ST ATE FIRE MARSHALL FOR SMOKE ALARMS. NOTE: 11 OV SMOKE DCT. PERMANENTLYWIRED IN W /BATT.BACK UP & CARBON MONOXIDE ALARM PER THE 2016 CEC ELECTRICAL CODE ARTICLE 21 O, 12 ARC~FAUL T CIRCUIT-INTERRUPTER PROTECTION IS REQUIRED IN ALL 1 20~VOL t, SINGLE PHASE, 1 S· AND 2.0-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, PARLORS, LIBRARIES,. DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS. ALL APPLIANCES TO HAVE SEPARATE DEDICATED CIRCUITS AND SIZED ACCORDING TO THE APPLIANCE SPECIFICATIONS SUCH AS, REFG., DISHWASHER, TRASH COMPACTOR, GARBAGE DISP., OVEN, RANGE,MICROWAVE, FAU., AIR COND., VAC., ECT. THE ELECTRICIAN TO CHECK WITH THE OWNER FOR THE PLACEMENT AND NUMBER OF TELEVISION, TELEPHONE, & INTERCOM OUTLETS. ALL ELECTRICALWORKTO BE DONE AS PER CEC. ALL CFCI OUTLETS TO BE DOUBLE PROTECTED WITH AFCI TELEVISION, PHONE & TELEPHONE OUTLETS IN EVERY ROOM ALL ELECTRICAL OUTLETS SPECIFIED IN CEC SHALL BE TAMPER RESIST ANT . . . CHECK WITH OWNER FOR PLACEMENT ALL CFCI OUTLETS TO BE DOUBLE PROTECTED WITH AFCI 3'011XS'011 SH 31011XS1011 SH MANDATORY (CBEES 150.0(K) A) BATHROOMS: UGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE THE FOLLOWING: AT LEAST ONE HIGH-EFFICACY FIXTURE SHALL BE INSTALLED IN EACH BATHROOM. ALL OTHER BATHROOM LIGKflNG SHALL BE HIGH EFFICACY OR CONTROLLED BY A VACANCY SENSOR; B) GARAGES, LAUNDRY ROOMS , AND UTILITY ROOMS: UGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR PR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY AND CONTROLLED BY A VACANCY SENSOR C) ROOMS OTHER THAN KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, OR UTILITY ROOMS: L:IGHTING FlXTURES AND WITCHES . . SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY OR CONTROLLED BY EITHER A VACANCY SENSOR OR DINNER. D) OUTDOOR LIGHTING : LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOROR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY EXCEPTION.: LOW-EFFICACY LIGHTING CONTROLLED BY A MOTION SENSOR AND Erri-lER A PHOTO CELL OR ASTRONOMICAL TIME CLOCK HIGH EFFICACY LUMINARIES OTHER THAN OUTDOOR HID: CONTAIN ONLY HIGH EFFICACY LAMPS AS OUTLINED lN TABLE 150-C, AND DO NOT CONTAIN A MEDIUM BASE SCREW SOCKET[E24/E26]. BALLASTS FOR LAMPS 13 WATTS OR GREATER ARE ELECTRIC AND HAVE OUTPUT FREQUENCY NO LESS THAN 20 kHz •• · HIGH EFFICACY LUMINARIES -OUTDOOR HID: CONTAIN ONLY HIGH EFFICACY LAMPS AS OUTLINED IN TABLE lSO-C, LUMINAIRE HAS FACTORY INSTALLED HID BALLAST. OCCUPANT SENSORS: SHALL COMPLY WITH SECTION 119[ D }AND SHALL NOT TURN ON AUTOMATICALLY OR HAVE AN ALWAYS ON OPTION •. LUMINAIRES THAT ARE RECESSED IN INSULATED CEILINGS ARE APPROVE.D FOR ZERO CLEARANCE INSULATION COVER [IC] AND ARE CERTIFIED TO ASTM E283 ANO LABELED AS AIR TIGHT [ AT] TO LESS THAN 2.0 CFM AT 78 PASCALS AN INTERMITTENTLY OR CONTINUOUSLY OPERATING LOCAL MECHANICAL EXHAUST SYSTEM [ WITH OUTDOOR AIR] SHALL BE INSTALLED IN EACH Kl'rCHEN AND BATHROOM COMPLYING WITH ASHRAE STANDARD 62.2-2007 AS ADOPTED BY THE CALIFORNIA .ENERGY COMMISSION. INTERMITTENT LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 50 CFM IN BATHROOMS AND 100 CFM IN KITCHENS. CONTINUOUS LOCAL VENTILATION EXHAUST AIRFLOW RATES SHALL BE 20 CFM IN BATHROOMS AND 5 ACH [AIR CHANGES/HOUR] IN KITCHENS BASED ON KITCHEN VOLUME. AFC! GFa s F-S vs OSP o-s ELECTRICAL PLAN LEGEND 110V ELECTRIC · OUTLETS 11 OV SMOKE DET. PERMANENTLY WIRED IN W / BATT. BACK UP & CARBON MONOXIDE ALARM ARC FAULT CIRCUIT PROTECTED GROUND-FAULT CKT INTERRUPTER SWITCH FLOURESCENT SWITCH VACANCY SENSOR SWITCH · SWITCH FOR PHOTO CONTROL WI MOTION SENSOR DIMMER SWITCH 220V CAN LIGHT LED SPECIAL TY UGHTING INDUSTRIES ADJUST ABLE DOWN LIGHT #1000 (1005-LEDZ·*H,927- APH-CZl 4LT2-.. ·••• ... A DISCONNECT WPGFCI ft) ~ "'OR WATERPROOF 110VELECTRIC OUTLETS EXH. FAN PROVIDING TEN AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPTABLE DISCHARGE POINT FOR EXHAUST AIR TO BE AT LEAST 3 FEET FROM ANY OPE!'l!NG WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING NUTONE #ZN110HL DUCT AS PR MANUFACTURES SPEC. 110 CFM ENERGY ST AR RA TED ULTRA GREEN W/ HUMIDISTAT & MOTION SENSING SOUND RATING 0.3 SONES UL APPROVED FOR OVER TUBS OR SHOWERS UGHT FIXTURE . FLOURESCENT W/ BALLASTS LIGHTS TO HAVE EFFICIENCY OF AT LEAST 40 WMENS PER WATT 2016 ENERGY LIGHTING STANDARDS KITCHEN AT LEAST HALF THE INSTALLED WATTAGE OF LUMINARIES [ EXCEPT LIGHTING INTERNAL TO CABINETS] IN KITCHENS SHALL BE HIGH EFFICACY: LOW EFFICACY FIXTURES MUST BE SWITCHED SEPARATELY. LIGHTING INTERNAL TO CABINETS SHALL USE NO MORE THAN 20W OF POWER PER LINEAR FOOT OF ILLUMINATED CABIN CT. GARAGE, LAUNDRY ROOM, UTILITY ROOM BATHROOM OUTDOOR UGI-ITING ATTACHED TO BUILDINGS COMMON AREAS OF LOW RISE. RESIDENTIAL BUILDINGS WITH 4 OR MORE DWEWNG UNITS RESIDENTIAL PARKING LOTS AND GARAGES FOR 8 OR MORE VEHICLES FIXTURES AND SWITCHES SHOWN ON FLOOR FOR \ITILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY AND CONTROLLED BY A VACANCY SENSOR BATHROOMS: LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE THE FOLLOWING: . . . AT LEAST ONE HIGH-EFFICACY FIXTURE SHALL BE INSTALLED IN EACH BATHROOM. ALL OTHER BATHROOM LIGHTING SHALL BE HIGH EFFICACY OR .CONTROLLED BY A VACANCY SENSOR. LIGHTING FIXTURES AND SWITCHES SHOWN ON FLOOR OR UTILITY PLANS SHALL DEMONSTRATE ALL LIGHTING IS HIGH EFFICACY EXCEPTION : LOW-EFFICACY LIGHTING CONTROLLED BY A MOTION SENSOR AND EITHER A PHOTO CELL ORASTRONOMI.CAL TIME CLOCK . HIGH EFFICACY OR OCCUPANCY SENSOR . . MUST MEET NONRESIDENTIAL LIGHTING ST AND ARDS RONS HOUSE PLANS SCALE: 1/4"=1'0" CONTRACTOR: DATE: 4-12-18 OWNERS NAME JESSE SMITH (760) 724-41 59 ORA WN BY: RTL #2862 OWNERS PHONE# (760) 504-8987 DRAWING NUMBER 9 OF 12 PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD (MDF ), AND HARDWOOD PLYWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION ST AND ARDS. A LETTER FROM THE FROM GREEN BUILDING CODE REQUIREMENTS NOTES THE INSTALLER AND OR THE BU1LDING OWNER CERTIFIED WHAT MATERIAL HAS BEEN USED AND DOCUMENTING ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR (CGBSC4.504.5) BJ MOISTURE CONTENT Of BUILDING MATERIALS USED IN WALLS AND FLOOR FRAMING 1S TO BE CHECKED FOR THE MINIMUM REQUIREMENTS BEFORE ENCLOSURE. MOISTURE CONTENT SHALL BE VERIFIED BY EITHER A PROBE TYPE OR CONTACT TYPE MOISTURE METER. A CERTIFICATE OF COMPLIANCE INDICATION DATE OF TEST LOCATION AND RESULTS ISSUED BY A THE FRAMER SUBCONTRACTOR OR GENERAL CONTRACTOR MUST BE. SUBMITTED TO THE BUILDING INSPECTOR (CGBSC 4.505.3) AUTOMATIC IRRIGATION SYSTEMS CONTROLLERS INSTALLED AT THE TIME OF FINAL INSPECTION SHALL BE WEATHER-BASED( CGBSC 4.304.1) JOINTS AND OPENINGS, ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENING WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY (CGBSC 4.406.1) CAL GREEN APPLIES TO ALL NEW RESIDENTIAL OCCUPANCIES INCLUDING LOW RISE AND. HIGH RISE BUILDINGS • IT ALSO APPLIES TO ALL RESIDENTIAL ALTERATIONS AND ADDITIONS WHERE THE ADDITIONS OR ALTERATION INCREASES THE BUILDING'S CONDITIONAL AREA VOLUME OR SIZE . THE REQUIREMENTS APPLY ONLY TO WITHIN THE.SPECIFIC AREA OF THE ALTERATION OR ADDITION THE CALIFORNIA GREEN BUILDING CODE APPLIES TO ALL RESIDENTIAL BUILDING WHICH ARE UNDER THE JURISDICTION OF HCD: THE INCLUDES ALL BUILDING WITH AN OF THE FOLLOWING OCCUPANCIES : SINGLE FAMILY DWELLINGS DUPLEXES HOTELS, MOTELS, APARTMENTS, CONDOMINIUMS, RAW HOMES, ECT. . ' ' ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH voe AND OTHER TOXIC COMPOUND LIMITS (CGBS4.504.2.1) PAINTS,STAINS ANO OTHER COATINGS SHALL BE COMPLIANT WITH voe LIMITS (CGBSC 4.504.2) AEROSOL PAINTS AND COATING SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS OF voe AND OTHER TOXIC COMPOUNDS' (CGBSC 4.504.2.3) DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT voe LIMIT FINISH MATERIALS HAVE BEEN USED. A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT MATERIAL HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. ( CGBS 4.504.2.4) THE PLUMBING FIXTURES AND PLUMBING FITTINGS SHALL MEET THE STANDARDS NOTED BELOW · TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: 1 J WATER CLOSET, GRAVITY TANK· TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1 .28 GALLONS PER FWSH MAX. 2J SHOWER HEAD= 2.0 GPM MAX. 3] KITCHEN FAUCETS= 1.8 GPM MAX. 4]LAVATORY FAUCETS= 1 .5 GPM MAX. 5] URINALS .5 GALLONS PER FLUSH J IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC G)PERMANENT VACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALLS AND FLOORS FRAMING SHALL NOT BE ENCLOSED WHEN FRAMING MEMBERS EXCEED 19% MOISTURE CONTENT FlFTY PERCENT OF FLOOR AREA RECEIVING RESILIENT fLOORING SHALL COMPL y WITH THE voe EMlSSJONS LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS ( CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED AND THE RESILIENT FLOOR COVERING INSTITUTE (RCFI ) FLOOR SCORE PROGRAM CGBSC 4.504.4 POLLUTANT CONTROL: DURING CONSTRUCTION, ENDS OF DUCT OPENINGS. ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED. CGC 4.504.1 NOTE ON THE PLANS THAT PRIOR TO FINAL INSPECTION THE LICENSED CONTRACTOR, ARCHITECT OR ENGINEER IN RESPONSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST PROVIDE TO THE BUILDING DEPARTMENT OFFICIAL WRITTEN VERIFICATION THAT ALL APPLICABLE PROVISIONS FROM THE GREEN BUILDING STANDARDS CODE HAVE BEEN IMPLEMENTED AS PART OF THE CONSTRUCTION. CGC 102.3. CARPET AND CARPET SYSTEMS SHALL &E COMPLIANT WITH voe LIMITS. A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT MATERIAL HAS BE USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR ( CGBSC 4.504.3) DUCT OPENINGS ANO OTHER RELATED AIR DISTRIBUTION OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED, DURING CONSTRUCTION ENDS OF ALL CGC 4.504.1 MINIMUM OF 65% OF CONS1RUCTION WASTE GENERATED AT THE SITE IS ONERTED TO RECYCLED OR SALVAGE PER. CGC 4.408.1 BEFORE FINAL INSPECTION A COMPLETE OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO BU1LDING OCCUPANT OR OWNER • CONTRACTOR OR OWNER SHALL SUBMIT AN AFFIDAVIT THAT CONFIRMS THE DELIVERY OF · MAINTENANCE MANUAL (CGBSC4.410.1) GLAZINGFRAMES MADE OF VINYL MATERIALS SHALL HAVE WELDED CORNERS, METAL . REINFORCEMENT IN THE INTERLOCK AREA, AND BE CERTIFIED TO THE MOST CURRENT EDITION OF ANSI/AAMA/NWWDA 101/1.S.2 ASSEMBLY REQUIREMENTS REQUIREMENTS BE CONSTRUCTED OF MULTI PANE GLAZING WITH A MINIMUM OF ONE TEMPERED PANE MEETING REQLilREMENi'S OF 2406 SAFETY GLAZING (CRC R337.8.2. l) 'PER 2016 GREEN CODE SEC 4.506. 1 MECHANICAL EXHAUST FANS WHICH EXHAUST DIRECTLY FROM BATHROOMS SHALL COMPLY WITH THE FOLLOWING: 1. FANS SHALL BE ENERGY ST AR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BU1LDING. 2. UNLESS FUNCTIONING AS COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM • .FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANG OF 50 TO 80%." HOT WATER PIPING MUST BE INSULATED PER CEC 150.0 (J) AS FOLLOWS: A) ALL HOT WATER PIPING 3/4" ·OR LARGER OR PIPING BURRED BELOW GRADE B) THE FIRST 5'0" OF HOT & COLD PIPING FROM THE STORAGE TANK C) ALL PIPING IN A RECIRCULATION SYSTEM D) ALL PIPING FROM THE HEATING SOURCE TO THE KITCHEN FIXTURES A. PROVIDEA{;l)NTINUOUSLY OPERATING EXHAUST FAN OR ANO INTERMITTENTLY OPERATED VENTILATION FANS THAN SHALL BE RATED AT 1.0 SONE OR LESS. INTERMITTENTLY OPERATED LOCAL EXHAUST FANS SHALL BE RA1ED AT 3.0 SONES OR LESS. THE SOUND REQUIREMENT IS NOT REQUIRED IF THE FAN IS SEPARA1ED FROM THE HABITABLE SPACE BY AT LEST 4' O" OF DUClWORK. B. IF THE VENTILATION/EXHAUST SYSTEM IS OPERATED BYA CONTROLLER OR SWITCH, NOTE ON PLANS THAT A LABEL OR SIGN IS REQUIRED AT THE CONTROLLER OR SWITCH TO INFORM THE OCCUPANT THAT THE FAN IS A WHOLE.HOUSE VENTILATION FAN THAT SHOULD OPERATE WHENEVER THE HOME IS OCCUPIED. TABIE7.t PRESCRIPTM:i DUCT SIZING IEQUlREl\leNTS~ ASHRM:62.2) DuotT-·~ Dud fluot EXH. FAN PROVIDING TEN AIR CHANGES PER HOUR DUCTLESS FANS ARE NOT ACCEPT ABLE DISCHARGE POINT FOR EXHAUST AIR MIIIRaling (o::fmat0.25 00 11!1 10!! 125 511 811 100 125 Broan LlOOL Galvanized Steel 108 CFM 0.8 A TO BE AT LEAST 3 FEET FROM ANY OPENING WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING NUTONE #lN11 OHL 6" DUCT 110 CFM ENERGY ST AR RA TED ULTRA GREEN W/ HUMIDISTAT & MOTION SENSING SOUND RA TING 0,3 SONES UL APPROVED FOR OVER TUBS OR SHOWERS EXHAUST FANS WHICH TERMINATE OUTSIDE THE BU1LDING ARE PROVIDED IN EVERY BATHROOM THAT CONTAINS A SHOWER OR TUB UNLESS FUNCTIONING AS A COMPONENT · OF A WHOLE HOUSE VENTILATION SYSTEM FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH CAN ADJUST BETWEEN SO TO 80 PERCENT . 'in. w.a.l Maximmn Allowable lllllltl..ength (ft) . !li;,,,O!ler, /"a,\ ,.,.__ Du.a Smoaihlluct 3 X X X X 5 X X X 4 70 . 3 . X X 1115 35 ,5 .. X 5 NL 11:1 35 30 NL 135 85 55. 6 NL NL t25 115 NL NL NL 145 7 """' illbave NI. NL . NL NL NL Nt. NL NL Tdai!i,....,asS1'IDl!Sm>•-Deliw:t1li.ff.<Jfalu .. allle ,filreachlllln.ell>aw,critliJl!t,.lnil!lplllatilo.-KI ~ in Tialile 7.1 i!inotalilMe<I, Farfan,mlilll! valbell<llfis1Ed.1151!""fll!ll<f~•all11,. This lallleis nat a~ fa-fan liltinas,. 125 clin. . Nl.. = m limit on, GIIIC!tlenglb cf lhiis !il:le. . · . X = eatan-o.,any ..... ,if duotllif llus siz,o with iESIIRlelllumsanllfillingsd e,u:eedtt,e r.llell Jl"!S!ilffl! ~ (ll.2lHaw;g.), N'Gille:mler 'wn\ i&lhe5'111!!Z'lllllitter<>lillllmlw,c.l a) Oellelmine lite duct lf1i!llfllial 1hat will Ille used for flleillllllidlafion ($MQO!h-Otr flex.). Duct sizing will 11se Ille Table 7'.1 llOlumns 1111w !he se.illded fype. of lllill:t. b) lden1i{y fhefan mling(s) W!elUO pooyide whole-building amf focal \lfflllifalim exb!IIIIII: (clin)- c;) Seilect lhe column lhllt con,espontl'II 1D Ule requlmd fan ralilllg fl!riie eystem. If 11le required filn miing {aTrliow din) is nal:s!IDWII on.Um Cllartand fairs belween Galumns, use Ille.next highest ran RIiing lllliwM ~~ fhetluc:t lenglll and diameter. TIie Table is not appllcabJe bfan r~ greaterlhan 125 ctm. d) setiecl lh~ p1efem1d dllct diamelerio delelmine !he llllfflilSflOIKg mioonwm allowable duct lenglh fl0.111 lhefan eling oollJmn fareach exhaust fall. IFO£e&dl tum, elbow arlittillg in Ille lim:t NI\ sublract 15 reet oflienglh froin the alowallledw:t lenglhspecifiell ill ttle Tallie. If · the alawabl'e (englh; af {slrai!lht) dl.lcltis not Sllffiaent for lhedesign, select tie next higher diameter of dlmt, allll mcnulate·lhe ailowam:a Aft "Nl.."in lhe mble indicates that any lenglh ofd'.w:tfor1hat diameter jg In, Cllll!ll]llance. Sone In·Line Ventilator Mor.ev Item# bci877524 Model# L100L r-·-.. I I □Compare , ---··-······· . J MIN. EFF. 94% AFUE 1 5 SEER Condenser Minimum Requirement ALL DOMESTIC HOT WATER PIPING TO HAVE THE FOLLOWING MINIMUM INST All.A TION "PER SGBSC SEC 4.303.2 PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTING ( FAUCETS AND SHDWERHEADS) SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE { CPC ) AND TABLE 1401. 1 OF THE CPC. " PROVIDE ULTRA LOW FLUSH TOILETS ALL PLUMBING FIXTURES AND RTTINGS WILL BE WATER CONSERVING AND WILL COMPLY WITH THE CGBSC SEC.4.303.1 THE PWMBING FIXTURES AND PWMBING ATTINGS SHALL MEET THE STANDARDS NOTED BELOW TO MEET THE CAL GREEN 20% INDOOR WATER SAVINGS: !J WATER CLOSET, GRAVITYTANK•TYPE, FLUSHOMETER TANK TYPE, ELECTROMECHANICAL HYDRAULIC TYPE = 1.28 GALLONS PER FLUSH MAX. 2] SHOWER HEAD = 2.0 GPM MAX. 3] KITCHEN FAUCETS = 1.8 GPM MAX. 4JLAVATORY FAUCETS= 1.2 GPM MAX. SJ URINALS ,5 GALLONS PER FLUSH ] IN SHOWERS AND TUB-SHOWER COMBINATIONS, CONiROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC 6]PERMANENT VACUUM BREAKERS SHALL BE INSTALLED WITH ALL NEW HOSE BIBS. RECYCLING: THE CONTRACTOR SHALL SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN TO THE JURISDiCTION AGENCY THAT REGULATES WASTE MANAGEMENT PER CGC SECTION 4.408 POLLUTANT CONTROL: D.URING CONSTRUCTION, EN.OS OF DUCT OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED. CGC 4.504.1 POLLUTANT CONTROL: DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED. CGC4.504:l · POLLUTANT CONTROL: . VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED IN SECTION 4.504.3, AND TABLES 4.504.1, 4.504.2, 4.504.3, 4.504.5,. FOR, ADHESIVES, PAINTS,, AND COATINGS, CARPET AND COMPOSITION WOOD PRODUCTS. CGC SECTION 4.504.2 INTERIOR MOISTURE CONTROL CONCRETE SLABS WILL BE PROVIDED WITH A CAPILLARY BREAK CGC SECT10N 4.505.2.1 MOISTURE CONTROL FOR WOOD SHALL NOT EXCEED 19% BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURE CONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODS SPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION. INSULATION THAT APPEARS WET, OR HAS A HIGH MOISTURE CONTENT SHOULD BE REMOVED, OR ALLOWED TO DRY PRIOR TO ENCLOSURE THE MOISTURE CONTENT MUST BE DETERMINED BY THE CONTRACTOR BY ONE OF THE METHODS LISTED IN CGC SECTION 4.505.2 INSTALLED: 1/2" PIPE ( 1/2" INSULATION) 3/4" PIPE (1" INSULATION)' 1" TO 1°1/4" PIPE. ( 1-1/2" INSULATION). CPC 609. 1 1 & ES 150.0(J) A) ADDITIONALLY THE 1/2" HOT WATER PIPE TO KITCHEN SINK, AND THE COLD WATER PIPE WITHIN 5' OF THE WATER HEATER BOTH REQUIRE 1" MINIMUM INSULATION. ·es 150.0(J) BATH ROOM FANS SHALL BE ENERGY STAR RATED, VENTED DIRECTLYTO THE OUTSIDE AND CONTROLLED BY A HUMIDISTAT. CGC 4.506.1 ~**New 13 SEER condensers .can no longer be instalted in California under a~y cc,ndition. ~ INSTANTANEOUS WATER HEATERS SHALL HAVE ISOLATION VALVES ON BOTH ALL NEW WATER HEATER ( PER THE ENERGY STANDARDS) MUST BE DESIGNED SO THEY CAN BE ABLE TO CONVERT TO TANKLESS WATER HEATER IN THE FUTURE ES. 1 50.0(N). PROVIDE THE FOLLOWING DESIGN REQUIREMENTS FOR ALL NEW GAS WATER HEATER INSTALLED TO SERVE INDIVIDUAL DWELLING UNITS: . A) PROVIDE ON THE PLANS A COMPLETE GAS PIPE DESIGN. THE GAS LOAD FOR THE WATER HEATER SHALL BE A MINIMUM OF 200,000 BTU/HR. B) A CONDENSATE DRAJN INSTALLED NO HIGHER THAN 2" ABOVE THE BASE OF THE HEATER THAT ALSO ALLOWS FOR GRAVITY DRAINAGE. C)THE "B" VENT INSTALLED IN A STRAIGHT POSITION (NO BENDS) FROM THE ROOM CONTAINING . THE WATER HEATER.TO TH!: ROOF TERMINATION ( FOR FUTURE POSSIBLE SLEEVING FOR HIGH EFFICIENCY HEATER VENTING) D)A 120 VOLT RECEPTACLE ACCESSIBLE TO THE HEATER 1NSTALLED WITHIN 3 .FEET. THE COLD AND THE HOT WATER PIPING LEAVING THE WATER HEATER COMPLETE WITH HOSE BIBS OR OTHER FITTINGS ON EACH VALVE FOR FLUSHING THE WATER HEATER WHEN THEVALVES ARE CLOSED ES 110.3 RONS HOUSE PLANS SCALE: 1/4"~1'0" CONTRACTOR: DATE: 4-12-18 OWNERS NAME JESSE SMITH (760) 724-4159 DRAWN BY: RTL #2862 OWNERS PHONE# (760) 504-8987 DRAWING NUMBER 10 OF 12 2X STUDS 16" QC ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED MIN. FOUNDATION BOLTS. MIN. OF TWO 5/8" DIA. . X 14" [ 9" MIN. EMBEDMENT) BOLTS WITH 3" X 3" X 0.229" STEEL PLATE WASHERS. ON EACH ANCHOR BOLT, 4' MIN. 2X MUD SILL SURFACE WATER WILL DRAIN AWAY FROM BUILDING. THE GRADE SHALL FALL A MINIMUM OF 5% WITHIN THE FIRST 10 FEET[ 2% FOR IMPERVIOUS SURFACES]. ECTION 1803.3 NAT. OIL 18" *CONCRETE TO BE 2 500 PSI Ml @ 28 DAYS MIN. * SEE SOILS REPORT ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED MIN. FOUNDATION BOLTS. MIN. OF TWO 5/8" DIA. . X 14' [ 9' MIN. EMBEDMENT] BOLTS WITH 3' X 3" X 0.229" STEEL PLATE WASHERS ON EACH ANCHOR BOLT, 4" MIN. & 12" MAX. FROM EACH END AND MAXIMUM SPACING = 4'0'. HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 8' NAT. SOIL *CONCRETE TO BE 2500 PSI @28 DAYS MIN. * SEE SOILS REPOIU MIN 3 1.8" MIN & 12" MAX. FROM EACH END AND MAXIMUM SPACING= 4'0". HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. .r-15" ---'"' MIN 4" SAND 6 IL VISQUE MEMBRANE CENTER OF SAND . 4"! \coNC. SLAB W/#3 BARS@ 18' O.C. E.W. .QVER 4" OF SAND & SAW CUT SLAB @ 10'0' O.C.E.W. ( 1 )#SBAR T&B 1 /2"DRYWAU. EA. SIDE STUDS @16"0.C. 4" SAND NMEMBRANE OF SAND "CQNC. SLAB / #3 BARS@ 18" O.C. E.W. OVER 4" OF SAND 5./8" DRYWALL 1/2" DRYWAU. R•21 INSULATION FLOOR SHEATHING: 3/4"CDX PLYWOODT&G #48/2 4 EXTERIOR GRADE, GLUED & NAILED WITH 10d@ 6"0.C. E.N. &1 Od@ 10" 0 •. F.N. FLOOR JOISTS SEE FLOOR PLAN SEE ROOF PLAN 8.N. 8d @6"0.C. A35 @24' o.c. 2X FASCIA DBL. 2 X TOP PLATES 2 X 4 U.N.O. STUDS @ 1611 o.c. 2X FIRE BLOCKS BETWEEN AU. STUDS AND STAGGERED 2x SOLE PLATE SEE ELEVATIONS A-35@ 24" O.C. DBL 2X TOP PLATES & SAW CUT SLAB@ 10'0" O.C.E.W. 1 /2" DRYWALL ZX STUDS @ 1 6" QC 1 /2"DRYWALL EA. SIDE 1811 1 ) #5 BAR T&B ALL FOUNDATION BOLTS MUST BE HOT DIPPED ZINC COATED GALVANIZED MIN. FOUNDATIDN BOLTS. MIN. OF TWO 5/8" DIA. • X 14" [ 9" MIN. EMBEDMENT} BOLTS WITH 3' X 3" X 0.229" STEEL PLATE WASHERS ON EACH ANCHOR BOLT, 4"' MIN. 2" MAX. FROM EACH END AND MAXIMUM SPACING= 4'0". HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. "CONC. SLAB NAT. SOIL MIN ZX PRESSURE TREATED MUD SILL SURFACE WATER WILL DRAIN AWAY FROM BUILDING. THE GRADE SHALL FALL A MINIMUM OF 5% WITHIN . THE FIRST 10 FEET[ 2% FOR 1511 ( 1 )#SBAR T&B MIN 4" CONC. SLAB / #3 BARS@ 18" 0.C. E.W, OVER 4" OF SAND · & SAW CUT SLAB@ 1 O'O" O.C.E.W. ALL FOUNDATION BOLTS MUST BE HOT DlPPlill ZINC COATED GALVANIZED MIN. FOUNDATION BOLTS. MIN. OF TWO 5/8" DIA. • X 14" [ 9" MIN. EMBEDMENT J BOLTS WITH 3" X 3" X 0.229" STEEL PLATE . WASHERS ON EAC::H ANCHOR BOLT, .4" MIN. & 12" MAX. FROM EACH END AND MAXIMUM SPACING= 4'0'. HOLD DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 'CONC. SLAB IMPE.RVIOUS SURFACES]. SECTION 1803.3 NO STEM WALL WHERE DOORS OR OPENINGS OCCUR 1811 MIN 3" • SAND ( 1 }#5 BAR T&B 15" MIN * MINIMUM DISTANCE FROM FOUNDATION TO DAYLIGHT TO BE H/3 OR 7'0' WHICHEVER JS GREATER. * ALL CONCRETE TO BE DONE IN A MONOLITHIC POUR * SEE SIMPSON CATALOG FOR INSTALLATION OF ALL HOLDDOWNS • INSPECTOR WILL RECHECK FOR EXPANSM SOIL OR GRADING REQ!JIREMENTS AT FIRST INSPECTION. "CONC. SLAB W/#3 BARS@ 18' O.C. E.W. OVER 4" OF SAND & SAW CUT SLAB@ 10'0" O.C.E.W. . *CONCRETE TO BE 2500 PSI @ 28 DAYS MIN. SEE SOILS REPORT * ALL HOLDDOWNS MUST BE TIED IN PLACE.PRIOR TO FOUNDATION INSPECTION SIDE VIEW G 2 X 3 @4" O.C. X2 R-21 INSULATION 2 X 4 U.N.O. STUDS @ 16" o.c. 2X FIRE BLOCKS ETWEEN ALL STUDS AND STAGGERED 2X PRESSURE TREATED MUD SILL DBL FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS * 4 n DECK JOIST EA. SI.DE WITH ( 2) 5/8' BOLTS FRONT VIEW 6 X 6 @ 5' O.C. MAX. --------------------------------- A35@24"0.C. 8 6"0.C. !1 l 16D @16"0.C. FACE NAIL DBL TOP PLATE 2X STUDS@ 16" O.C. 2X SOLE PLATE 5/8" X 14" A.B. (MIN. 9" INT CONC. )MIN @4'0" O.C. W/NUT. & WASHERS INSTALLED. MIN. 2EACH PANEL SEE FOUNDATION PLAN 2XBEVELED BLOCKING W/[2] 16D • END TO R.R. 2X STUDS @ 16" o.c. [2] 16d SOLE PLATE TD STUD END NAILED Gd@6'0.C. 10d@6"0.C. SIMPSON A35@24"0.C. FULLY NAILED W/ 12 8d 1Gd@6'0.C. [1] 16d @ 16'0.C. FACE NAIL DBL TOP PLATE ] 16d TOP PLATE TO STUD 2X STUDS @ 16" o.c. 2X BlOCKJNG @ EA. STUD NAILED W/ [2] 16d E.N. TO EA STUD 2X STUDS @ 16" O.C. [2) 16d PLATE TO STUD HANDRAILS FOR STAIRWAYS HALF-CIRCUMFERENCE 4" MAX~-___ _ 1-1 /2"MIN. & 2" MAX. TOP STAIRS * 1 1/2" T02" ATTACH STRINGER WITH SIMPSON U214.NOTCH AS REQUIRED -.J!iOT SMALLER THAN} ...,....lliOT LARGER THAN} ~----;( A) MINIMUM CLEAR WIDTH OF 36", B) MINIMUM HEADROOM 6'·8", C) RISE TO BE BETWEEN 4" AND 7.75", ST AIRS TO BE CONSTRUCTED D) MINIMUM RUN OF 10" ( FOR WINDING STAIRS: 6" AND 10" MINIMUM AT.12" FROM INSIDE RADIUS), E) TREAD NOSINGS BETWEEN 0:75• AND 1.25" ON STAIRWAYS WITH AS PER C.B.C. TOBE DETERMINED IN THE FIELD MIN. 11" 4' o.c. 11" MIN • 61811 MIN HEAD RO M PERPEND! LAR TD NOSIN OF THE TREADS 34' TO 38" OVE NOSING · 1 1 /2" SOLID RISERS [ WHEN TREADS LESS THAN 11 "] MIN F) MINIMUM LANDING DEPTH EQUAL TO STAIR WIDTH, UP TO 44" G) HANDRAIL HEIGITT 34" TO 38" ABOVE NOSING OF TREADS, HJ INSTAL PERMANENTLY WIRED LIGHTING OF NOT LESS THAN 1 FOOT-CANDLE AT TREAD RUNS. I) STRUCTURAL DETAILS REQUIRED. THE ST AIRWAYS AND 1.ANDINGS TO HAVE A) MINIMUM LANDING DEPTH EQUAL TO STAIR WIDTH, UPTO 44" B) RISE TO BE BETWEEN 4" AND 7.75", C) MINIMUM RUN OF 10" ( FOR WINDING ST AIRS : 6" AND 10" MINIMUM AT 12" FROM INSIDE RADIUS), D) MINIMUM HEADROOM 6'-8", E) MINIMUM CLEAR WIDTH OF 36", F) HANDRAIL HEIGHT 34" TO 38' ABOVE NOSING OF TREADS ALL HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE ST AIRS. HAND GRIP PORTION OF ALL HANDRAILS SHALL NOT BE LESS THAN 1·1/2' NO MORE THAN 2" IN CROSS SECTIONAL DIMENSION, OR SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. THE WALLS AND SOFFITS OF THE ENCLOSED USABLE SPACE UNDER INTERIOR ST AIRS SHALL BE PROTECTED ON THE ENCLOSED SIDE AS REQUITED FOR ONE·HOUR FIRE-RESISTIVE CONSTRUCTION 7-::::~11 r--1-1.Jl"HIS HEIGHT TO BE D THE FIELD MIN.4" ANO ~-...... _,,.~--'-! CARRIAGE 2 X 14@ 12" 0.C. RAMSET SHOT PINS 3" E •1799 ~/8" DRYWALL TYPE X COVE MOLD WALL STRINGER THE TRIANGULAR OPENINGS FORMED BY THE RISER, T AD AND THE BOTTOM ELEMENT OFA GUARDRAIL AT A STAIR SHALL BE LESS THAN 6" RONS HOUSE PLANS SCALE: 1/4",.1'0" CONTRACTOR: DATE: 4-12-18 OWNERS NAME JESSE SMITH (760) 724-4159 DRAWN BY: RTL #2862 OWNERS PHONE# (760) 504-8987 DRAWING NUMBER 11 OF 12 ------- CCGG OR ECCGG FULLY BOLTED GXHDR W / [2] 5/8" 0 MACHINE BOLTS [MB) INTO GX HDR & [2] ~ 5/8' 0 M.B. INTO PoST·~t--- FOR ECC OR FULLY BOLTED W/[4] 5/8"0 MACHINE BOLTS [MB) INTO 6X HOR & [2] 5/8" 0 M.B. INTO POST FOR CC E ROOFPlAN A35 @24" O.C. R-30 INSULATI 5/8" DRYWALL [1] 16D @16"0.C. FACE NAIL DBL TOP PLATE A35@24"0.C. 8D 1/2" DRYWALL 2X STUDS @ 16" O.C. R-19 INSULATION 2 XG U.N.O. STUDS @ 16" o.c. A CB66 ~ FULLY BOLTED ~ W/ [2] 5/8" 0 -- MACHINE BOLTS [MB] 8d@6' O.C. TYPICAL GABLE END PLYWOOD ROOF SHEATHING SEE ROOF PLAN GABLE ASSEMB_~L~Y--i:;i._l [2] 16d @ 811 o.c. SEE ELEVATIO 1Gd@ 16" O.C. FACE DBL.PLAT .. ~--- SEE FLOOR PLAN FOR HEIGHT BL 2X TOP PLATE --"li'~-----'1/2' DRYWALL /8" X 14n A.B. ( MIN. 9" INTO CONC.)MIN @4'0" O.C. W/NUT & WASHERS INSTALLED. MIN. 2 EA H PANEL SEE FOUNDATION PLAN TYP. INTERIOR NON BEARING 1 /2" DRYWALL 2X FIRE BLOCKS BETWEEN ALL STUDS AND STAGGERED 2XPRESSURE TREATED MUD SILL 2X BLOCKING @ EA. STUD NAILED W/ [2) 16d £.N. TO EA STUD 2X STUDS @ 16" O.C. [2] 16d PLATE TO STUD RAM SET 311 ESR-1799 X STUDS @16"0.C. MAX. 12" FROM EDGE & 24"0.C. SEE FOUNDATION PLAN ~i:i:!~~~i:IW~~~?r---sEE FOLINDATION PLAN NAT. SOIL NOTES 1 DIMENSIONS HAVE PREFERENCE TO SCALE. 2 BALLOON FRAME ALL WALLS OF ROOMS WITH SLOPING CEILINGS. 1/2" CLEAR BETWEEN TRUSSES AND NON-BEARING PARTITIONS. 3 MAXIMUM UNBRACED HEIGi-ff FOR 2X4,3X4,2XS,2X6 sruos IS 10' FOR BEARING WALLS 4 . MAXIMUM BRACED HEIGHT FOR STUDS OF NON-BEARING WALLS IS AS FOLLOWS: 2X4&3X4 IS 14', 2XS IS 16',AND 2X6 IS 20' 5 ALL FRAMING LUMBER TO BE D.F.#2 OR BETTER ,AND USE D.F.S.S. FOR BEAM 6" OR LARGER 6 ALL CRIPPLE WALLS 14" OR LESS IN HEIGHT SHALL BE SOLID BLOCKED. 7 EVERY OPENING IN ANY EXTERIOR WALL SHALL BE FLASHED WITl-1 SHEET METAL AND OR WATERPROOF BUILDING PAPER. 8 CUTTING, NOTCHING AND DRILLING OF STUD WALLS SHALL COMPLY WITH THE C.B.C •• 9 ALL STUD WALLS TO HAVE A DOUBLE TOP PLATES WITH A MIN. 48" LONG LAP SPLICES. 10 WALL BRACING IN EVERY STUD WALL WITH 1X6 LET IN BRACES AT NO MORE THAN 60 DEG. NOR LESS THAN 45 DEG. FROM HORIZONTAL, OR PLYWOOD SHEAR PANEL BRACE, FROM EACH CORNER AND EVERY 25' OF LINEAL WALL 11 0 TRA OR S L CHECK ALL DI NS, A NOTIFY E STARTING 12 DRY WALL, LATH & PLASTER, STlJCCO CONTRACTORS TO TAKE PRECAUTIONS TO MINIMIZE CRACKING. PRECAUTIONS SHALL BE TAKEN TO MAXIMIZE WATERPROOFING. ALL WORK SHALL COMPLY WITH THE CB.C 13 ALL BEDROOMS TO HAVE AT LEAST ONE WINDOW WITl-1 A MAX. SILL HEIGHT OF 42" AND WITH A OPENABLE AREA OF NOT LESS THAN 5.7 SQ. FT., 24" NET CLEAR OPENING HEIGHT, 20" NET CLEAR.OPENING WIDTH. C.B.C. 14 PROVIDE ATTIC VENTAREA MORE THAN 11150TH OF THE ATTIC AREA. ASPER C.B.C •• 15 RACE RIDGE AND PURLINS ,HIPS, AND VALLEYS TO INTERIOR BEARINGWALLS @6'0" 0.C.MIN. U.N.O. 16 EE SIMPSON CAT ALO GUE FOR CORRECT CONNECTOR AND NUMBER AND PLACEMENT PRIOR TO ORDERING. 17 DRAFTSMANS RESPONSIBILITY IS LIMITED ONLY TO ASSISTING THROUGH PLAN CHECK. OWNER TO CHECK WITH STRUCTURAL ENGINEER FOR LAERAL VE !CAA ND ER AL .P OCO I SASMAXIMUM 18 CERAMIC TILE TO BE SET IN FULL BED OF MORT AR ON 1 5# FELT OR BETTER. CONTRACTOR TOT AKE PRECAUTIONS TO MINIMIZE CRACKING. PRECAUTIONS SHALL BE TAKEN TO MAXIMIZE WATERPROOFING. ALL WORK TO BE DONE.IN A GOOD WORKMAN LIKE MANNER. 19 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 40. ALL BOLTS SHALL COMPLY WITH ASTM A-307 20 ALL ROOFING TO BE WATERPROOF AND INSTALLED AS PER MANUFACTURES SPECIFICATIONS AND DONE IN A GOOD WORKMAN LIKE MANNER. 21 RON ISA DRAFTSMAN WHO IS WORKING FOR YOU AS YOUR EMPLOYEE. YOU THE EMPLOYER TO PROVIDE ALL INSURANCE'S FOR THIS JOB 22 ALL ELECTRICAL WORK SHALL BE DONE IN A GOOD WORKMAN LIKE MANNER AND CONFORM TO THE CEC 23 ALL PLUMBING WORK SHALL BE DONE IN A GOOD WORKMAN LJKE·MANNER AND CONFORM TO THE CPC 24 ALL MECHANICAL WORK SHALL BE DONE IN A GOOD WORKMAN LIKE MANNER AND CONFORM TO CMG 25 ALL CONCRETE AND STUCCO WILL CRACK, THE CONTRACTOR SHALL TAKE PRECAUTIONS TO LIMIT THIS CRACKING. 26 LL FRAMING TO BE DONE IS A GOOD WORKMAN LIKE MANNER AND TO CONFORM TO THE CBC. 27 ·ALL NAILING AND NAILING CONNECTIONS SHALL CONFORM TO THE CBC 28 LL NAILS SHALL BE COMMON WIRE AND.SHALL BE PER CBC. 29 HE OWNER AGREES TO THE AFORE MENTIONED CONDITIONS BY ACCEPTING THE-SE PLANS AND AGREES TO FURNISH NEW OWNER WITH A COPY 30 THIS HOUSE SHALL CONFORM TOTHE STATE OF CALIF.. ENERGY COMMISSIONS TITLE 24 REGULATIONS. 6'0.C. 2XBEVELED BLOCKING W/ [2] 16D A. END TO R.R. [3] 8D FREEZE BLOCK TO TOP PLATE TABLE FASTENING SCHEDULE CONNECTION 1. Joist to sill or girder 2. BRIDGING TO JOIST JOI sole plate to Joist or blocking at braced wall panel 7. top plate to stud 8. stud to sole plate . double studs 1 O. double top plates double top plates 1. blocking between joist or rafters to top plate 12. rim joist to top plate . top p ates, aps and 1 4. continuous header, two pieces 5. ceilir,g Joists to plate 16. continuous header to stud 7. caiHn9 joists, laps over partitions see sactIon 2308.10.4.1, table 2308.10.4.1] s. ceI11ng 101sts parane rs see section 2308.10.4.1, table 2308.10.4.1I 9. raft,or to plate see section 2308.10.4.1, table 2308.10.4.1] , 111 diagonal brace to each stud and plate 1. 1 "x8u sheathing to each bearing wider than 1 Qx8" sheathing to each bearing 3. built-up corner studs 4. bUitt•up girder and beams . 2'' planks . jack ratter to hip a.roor rafter tu 2-by ridge beam 9. joist to band joist 31. wood structural panels and particleboard subfloor, roof and wall sheathing [ to framing] single floor [combination subloor•underlayment to framing] 32. panel siding [ to framing] 3. fiberboard sheating o 34. interior paneling For SI: 1 inch= 25.4 mm. FASTENING a,m . 3-31X 0.131 11 nails 3-3" 14gage staples 2-Bd common 12·1 'X 0.1311 2-311x0.1318 nails 2-3" 14guage staples 2-Bd common [2·112'x.0.131'1 3-8d common {2· 112''x 0.131'1 2-16d common [3-1/2"xO. 16i'] 16d common [3-112'1<0.1621 at 16' o.c. 3"x 0.131" nails at 811 o.c. 311 14 gage staples at 12'10.c. 3"=16d common [S-'.l/21'x0.162"] at 16" o.c. 4-3"X0.131" nails at 16" 4-3" i4gage staples per 16'' 2·16dcommon [3-112''X0.162i 3~ 3~ 0.131" nails 3-3" 14gage staples 4-8 common -1 .01 1' 4-S1'x.o.1s1" 4· 3''X.14gage staple 2-16d common [3--1/211x0.162'j 3-3'x 0.131" nails 3-311 14ga:ge staples o.c. common {3-1/2"x0.1ll5'i at 16" o.c. 0.131~ na11s:at 1211 o.C. 14 gage staples at 12'o.c. 8116d common [3· 1 /2'x0.162'] 112] 3'1< 0.131" nails 12] 3" 14 gage staples 3-8d common [2·112''X.O 1311 3-S''x 0.13111 nails 3-3" 14gage staples at o.c. 311X 0.131" at 611 o,c. 3" 14gage staple at 611 o.c . .mini um e .10.4.1 4-3''X 0.131 • nails 4· 3" 14gage staples mm1mum 3"x0.'131 11 nai 3' 14gage staples 20dcommon.{4"X0.192 32"o.c. 3"x 0.131" nails at 24110,c. 311 14gage staples at.24110.c. 2·2Dd common [4"X0.1921 3..S°x0.131" nails at 24110.c. 3-3" 14gage staples at 24"o.c. 6d common I3-112"XO.-t6211] 10 common 3 . 4-3''X 0.13111 nails at 24"o.c. 4-3" i4gage staples at 24'o.o. 3-10d common [S"x0.1481 4-3"x 0.131 11 nails at 24110.c. 4-3' 14gage staples at 24"o.o. 2-16d common [3"J<0.162"] 3-3"X O. 1-3f11 nails at 24110.0. 3-3" 14gage staples at 24"o.<. 2·16d common 3'x .16 ' 3-311x o.1s1n nails at 24"o.c. 3-3" 14gage staples at 241'0.c. 2·16d common [3'x0.1621 3-S"x 0.13111 nails at 24"o.c. 3-3" 14gage staples at 24'<>.o. 3·16d common [3"x0, 162'1 4-S"x 0.13111 nails at 24"o.c. 4-3' 14gage staples at 24"o.c. •16dcommon [3''X0.162"] 4-S"x 0.131" nails at 24110.0. 4-3" 14gage staples at 24"o.c 1 ess 2~3/811x0.113 11 n 1-3/4" 16gage 0 19/32' to 3/4" 8d ~r 61 • 2·3/Snx0.113" P 211 16 gage P 7/8" tO 111 8d C d d 1·1/8" to 1-1/4" 10do18d 3/411 and less Gd e 7 /811 to 111 8d O d d 1-1/8' to 1-1/4" 10d 018d 1/2" and less Gd ' 5/8" 8d t no. 11 gage roo mg na, Gd common nail (2"x0.113"] no. 16 gage staple i 25/32" no. 11 gage roofing miil h 6d common nail [Z"x0.113"] no. 16 gage staple 1 411 4d 3/8' Gd' a. Common or box nails are permitted tQ he used except where o~herwise stated. LOCATION toenail toenail each end face nail face nail ce na1 typical face nail brace,fwaU panels end nailed end nailed end nailed face nail . typical.face nail lap splice toe nail toe nair face nail 16" o.c. along edge toe nail toe nail face nail face nail oe nail face nail face nai face hail 2411 o.c. 1611 o.c. 1611 o.c. ace na, at top an ottom aggered on opposite sides ace nail atends and at each splice at each bearing face nan toe nail ace nail toe nail face nail face nail b. Nalls spaced at 6 Inches on center at edges, 12 inches at Intermediate supports except 6 li1Ches at supports Where span are 48 inches or more. For nailing of wood structural panel and particleboard diaphragms and shear walls, refer to Section 2305,Nails for wall sheathing are perm!tted to be mrnmon, box or casing. c. Common or deformed $hank (6d -2 x 0.113"; 8d ~ 21/2 x 0.131"; lOd-3 x0.148~ ), d: Common (Eid -2 x 0.113"; Sd -21/2 x 0.131b; 10d -3 x 0.148~ }. e. Deformed shank(G(I -2 x 0.113"; &.I -21/2 x 0.131~; 10d -3 x 0.148" ). f. Corrosion-resistant siding (Gd x 17/8" 0.106; 8d l< 23/SQ 0.128 --i orcasing-(6d_ -i >1 0,099"; Sd -21/2 x 0.113") nail. g. Fasteners spaced 3 .inches on center at exterior edges-and 6 imhes on center at Intermediate supports, when used as structural SAeathing. Spacing shall be 6 inches on center .on the! edges and 12 Inches on center at Intermediate supports for nonstructural .applications, h. Corroslon-reslstant roofing nalls with 7/16-!nch-d-lameter head and 11/2-inch length for 1/2-inch sheathing and 1 3/4"'.'inch lengm for 25/32-lnch sheathing. L Corios!on-resistant staples with nominal 7 /16-inch crown and l 1/8-lnch iength for 1/2~!nch sheathing and 1 l/2-lnch length for 25/32-inch sheathing. Panel supports at · 16 Inches (20 Inches ff strength axis in the long direction of the panel, unless otherwise maiked). j, Casing (11/2 x 0,0B0~} or finish (11/2 x 0.072'' ) nails spaced 6 inches on panel edges, U Inches at intermediate supports. k. Panel supports at 24 inches. Casing o~ finish nalls spaced 6 Inches on panel edges, 12 inches at intennedlate supports. I. For roof srtaathlng apPl!catlons, 8d nal\s (21/2 x 0.113'') are the minimum required for wood structural panels. m.Stap!es shall h<M: a m!nimum-crown width of 7/16 inch. n. For roof sheathing applications, fasteners spaced 4 Inches on cent-er at edges, 8 Inches atintennediate support:s. o. Fasteners spaced 4 inches on ~nter at edge~, 8 lnches at intermediate supports f1)I' subfloor andwall sheathing and 3 inches on center at edges, 6 Inches at Intermediate supports for roof sheathing. p, Fasteners spaced 4 irn:hes on center at edges, 8 inches at tntermediate supports. ----------- RSIC-1 ACOUSTIC ASSEMBLY WALL ASSEMBLY DIRECT FIX TO WOOD STUD 210 Assembly 3 STC 60 ~ STC60 C0~1lTRUCTION * S/8• <Jwsum * 718" x. 25 guage furring Channel@ 24• o.c. * RSIC-1 clips at 48' o.c. * 2x4 wood studs@l6" o.c. * 6" 111lfaced fiberglass insulation cavity fully lllled * 2 Layers 5/8' Gypsum *TmNumberTLOl-210 RAL * UL U301, U305, U309, U311, U331, U334 UL usot OJos, u309 0311 U331 U334 · SOUND TllANSMISSION CLASS STCliO IC> PAC ln!amatlonal, lnc.-AU Rights Rosorved. C TYPICAL PIPE D METACAULK 1000 OUND RATING= STC 62 FIRE RATING= 4 HRS. ASTM E 814, UL 723 TUNNEL TEST, UL 1472, 1479, 2079,ULC·SC115-95 BASE ASSEMBLY H ~embly H Single ~ oeilfng, one-Hour Ratedltl t(X}ES ESR-1153., PfS f.li-.1 Ass,m1nty H carpet Options Bi15e ColllfMlllenls: 1. Sillglelill)lffl"of ~24 minim!Jm,sp111ttated~she&thing (sucl;as ~sE!jge™ «EdgeGmd""OSB, ar~lenl:), nai1edland giuedwlh aSIJl:lftol:Jradlmive. 2. flakJ~ f>llltecled lll' 210, 230,300, OI' 500jllist, With cin-center spa,cmg of 16' or less. fllrwlder S!lllcil1g. !JP to 24• on-cffiter maximum, \ISll! .11~• deep or!l)'eeler1f,i!IJ> 230,300, -or 560 jtlisls_ 3. Glmsfiber illSUl,e,tiO!Pl pliil:ed between the 1'.lll'jQJslsmdabllvethe bolmm11a!!ge. Seetablesfi:lrs,;iecillicatioos. 4. RCl. resilient chmmelsal: 'JS m<.:enler 5-. (lfle la;l'ef' W tl1i!ik T)lle C lt,pSllfll !)loaltl il'looringCcmpGnems,seetablesllefow:: 6. Fill1i!h loolln,g 7. Ac!lmti(; ffllill!i! 8. Urml~ (:1} Rir,...,.., m!mnsti"" al>o<it<ieop, inslallsliiort Ollllfin,,fl"'lt,II""""" ofllm """'""!:I:,~ ..... the ~~Assemb!i,s and!lpnnl,fer~ Gwie 1500, lOO:El,ESR-.!l:lS, and FlfS ~ ,21~ .. ~•1tiefiretresistsm:ellltlng; (II} I" stme ........it,lies, ~<A """IISliomaltis belcm ~ Seetables. RONS HOUSE PLANS SCALE: 1/4"=1'0" DATE: 4-12-18 OWNERS NAME JESSE SMITH CONTRACTOR: (760} 724-4159 DRAWN BY: RTL #2862 OWNERS PHONE# {760) 504-8987 DRAWING NUMBER 12 OF 12