Loading...
HomeMy WebLinkAboutCUP 16-07; CARLSBAD ELLERY RESERVOIR WCF; Planning CommissionI I i 1, I VICINITY MAP 2237 Janis Way Carlsbad CA, 92008 SCOPE OF WORK Project Description: A. Installation of 60' Faux Monoeucalyptus: 1. Installation of four (4) Omni-Directional antennas on faux eucalyptus tree 2. Installation of two (2) receive only Omni-Directional antennas on faux eucalyptus tree 3. Installation of one (1) 4' 0 performance microwave dishes on faux eucalyptus tree 4. Installation of 1' x 1' SCADA antenna on faux eucalyptus tree B. Installation of prefabricated 1 O'x24' shelter on concrete pad C. Installation of 60KW enclosed emergency generator with a 200 gallon diesel tank on concrete pad 1. Installation of prefabricated generator enclosure D Installation of 14' H. CMU retaining wall DEFERRED SUBMITTAL Generator contractor must submit construction plans directly to Fire as deferred submittal for installation of generator and 200 gallon diesel tank. SCALE The drawing scale shown in this set represent the correct scale only when these drawings are printed in as 24"X36" format. If this drawing set is not 24"X36" this set is not to scale. All drawings are schematic. Do not scale drawings to determine or verify any dimensions. Drawings of any size shall never be scaled for anything other than general reference. CONDITIONAL USE PERMIT Carlsbad Ellery Reservoir RCS Site Carlsbad, CA. T.O. #11 Project No. MP100611 PROJECT TEAM User: SDCSRCS 5575 Overland Ave. Suite 102 San Diego, CA. 92123-1294 Tel. : (858) 495-5523 Contact: Mr. Jaime Urrutia E-mail: jaime.urrutia@sdsheriff,org Civil Engineer: Stuart Engineering 7515 Metropolitan Drive, Suite 308 San Diego, CA. 92108 Tel.: (619) 296-1060 Contact: Mr. Stu Peace Architect: Sillman Wright Architects 7515 Metropolitan Drive, Suite 400 San Diego, CA. 92108 Tel.: (619) 294-7515 Fax: (619) 294-7592 Contact: Larry Sillman E-mail: LSillman@sillmanwright.com Electrical: Stantec 9191 Towne Center Dr. Suite 220 San Diego, CA. Tel. : (858) 622-27 43 Contact: Mr. Paul Ericson E-mail: speace@stuartengineering.com E-mail: paul.ericson@stantec.com •• Landscape: Neri Landscape Architecture 928 Hornblend St. Suite #3 San Diego, CA. 92109 Tel.: (858) 274-3222 Contact: Mr. Jim Neri E-mail: jim@nerila.com PROJECT NOTES City of Carlsbad -Development Permits P-2 A. Number of Parking Spaces Required: -No new parking required -One new parking space provided B. Average Daily Traffic generated by the project, broken down by separate uses -Once per month C. Potential impact on regional transportation system, including the cost of mitigation the associated impacts: -No impact on the regional transportation system D. Total Earthwork Volumes (cut, fill, remedial, import and export) -Total earthwork volume exported: E. Except in an emergency posing immediate public health and safety threat as allowed for emergency work under the provisions of the Carlsbad City Code pertaining to the Noise Ordinance, site construction and maintenance activities in or within 100 feet of site will only occur between 7:00 a.m. and sunset, Monday through Friday (8:00 a.m. to sunset on Saturdays). Work is not planned for Saturday's, should work be necessary. No work will be done on Sundays and the following Federal holidays: New Year's Day, Memorial Day, July 4th, Labor Day, Thanksgiving Day, and Christmas Day. F. The County shall conduct annual aesthetic inspections of the Regional Communications Systems facility to include both the mono-eucalyptus tree communications tower and the communications equipment shelter. The Sheriff's Department will ensure any required maintenance is performed including, but not limited to, replacing foliage as a result of leaf drop, replacing worn or torn screen/socks, repainting equipment predisposition to fading. The County will also inspect and provide for the upkeep of the communications the equipment shelter and associated facility improvements. ACCESSIBILITY DISCLAIMER This project is an unoccupied radio tower facility and, according to written interpretation from the California Department of the States Architects, is exempt from disable access requirements. PROJECT SUMMARY Applicant: County of San Diego Department of General Services 5560 Overland Ave. Suite 410 San Diego, CA. 92123 Tel. : (858) 694-3989 Contact: Mr. Thomas Hoerstman thomas.hoerstman@sdcounty.ca.gov Owner: City of Carlsbad 1635 Faraday Ave. Carlsbad, CA. 92008 Carlsbad Municipal Water District 5950 El Camino Real, Carlsbad, CA. 92008 (District Rep.) Point of Contact: Project Manager Julio Medina Sillman Wright Architects 7515 Metropolitan Drive, Suite 400 San Diego, CA. 92108 Tel.: (619)294-7515 Contact: Julio Medina JMedina@Sillmanwright.com PERMITS REQUIRED CUP Planning Commission PROJECT DATA Project Address: Assessor Parcel Number: Existing Zoning: Local Facilities Management Zone: Site Area: Proposed Structure Areas: Equipment Shelter: Generator Enclosure: Proposed Type Of Construction: Proposed Occupancy: Hazardous Materials: General Plan Land Use Designation: Existing Land Use: Proposed Land Use: Total Building Coverage: Building Square Footage: Percent of Site Landscaped Parking Spaces Required: Parking Spaces Provided: Average Daily Traffic Generated by the project: 2237 Janis Way Carlsbad CA, 92008 167-540-52-00 R-A-10,000 Zone 1 1.44 AC I 62,726 sf. 288 sf. 80 sf. Type V-B u Generator Diesel Fuel (200 gallons) Residential low-medium (RLM) City of Carlsbad water tank & cellular towers City of Carlsbad water tank & cellular towers, proposed additional communications tower for County Sheriffs & local Police & Fire Department. Shelter, Generator, Tower & Switch Gear 288 sf. 27% Existing 0 1 Once per month SHEET INDEX SHEET 1----·----· CITY OF CARLSBAD PLANNING COMMISSION Case Name:~ El\ee'=t·-- _£_~0\ r 1,1,,lc;.F Case No.: ClA'P lh-~O~'J~------ . . \\J,..11 1'-,-11 ,111.,-ln.-,-t LE::.:xh::,:,b:;:.1t .:;No;;.:. ;:;;:;f"\=:;;-;;;;;!;;;;.1.=:C.:D:.:a::te;.;: .:I;!;;!~ T-1 Title Sheet/ Project Data .. --·-·------------! !---·--··--~--------------Architectural 1--~~-~~~~-------------------------------------1 A-0 A-1 A-2 A-2.1 .,.·-••ss••••-- Site Plan Enlarged Site Plan Enlarged Area Plan Enlarged Equipment Floor Plan I Elevations ---------------------------~-- A-3 Site Sections 1--------.. -·----------------- A-4 Exterior Elevations --------------------------·----·-----·---------------------------1 ---------------------------------------; ------------------------ ,___Landscape_.·. . ..... __ -------·-·--------------- __ ~~~ _____ L_andscapeConcept Pl_an __ --------------· ------------------- --------·······--···-····------------------------i LEGAL DESCRIPTION: All of that portion of lot :J" of Rancho Agua, Hedionda, in the city of Carlsbad, in the county of Sa.n Diego, State of California, according to map thereof No. 823, filed in the office of the County Recorder of San Diego County, November 16, 1896 Described as Follows: Beginning at the most Northerly corner of lot 17 of Ocean View Estates as shown on map thereof No. 5825, filed in the office of the County Recorder of San Diego Count, January 25, 1967; Thence North 58°59'34" East, a distance of 242.89 feet to the true point of beginning of the portion to be described; thence from said true point of beginning South 23°20'06" East, a distance of 200.00 feet; thence South 65'20'06" East, a distance of 103.00 feet; Thence North 66'39'54" East, a distance of 115.00 feet; Thence North 33'41'38" East, a distance of 62.67 feet; Thence North 10'32'29" West, a distance of 139.44 feet; Thence North 69'20'06" West, a distance of 180.00 feet; Thence South 58°59'34" West, a distance of 139.14 feet to the true point of beginning. Note: Said land is now shown on parcel map No. 878 filed in the office of the County Recorder of San Diego County on July 3, 1972. APN: 167-540-52-00 APPLICABLE CODES All work shall comply with the following applicable codes: California Building Code 2016 Edition California Plumbing Code 2016 Edition California Mechanical Code 2016 Edition California Energy Code 2016 Edition National Electrical Code (NEC) National Fire Protection Association (NFPA) ANS/TIA-222-G Structural Standard for Antenna Supporting and Antennas Structures ASCE/SEI 7-05, Minimum Design Loads for Buildings and other Structures In the event of conflict, the most restrictive Code shall prevail. CUP 16-07 7J 1 1 rrnoDu:m ul, 11!1 Loo SAn )ICOO, CA Q 2 'i Oo IL0101011 /)I J rA10iOl04 ilO) Drawn By: J.M. No. Date ,..... ,..... Checked By: L.S. Issue Description SUBMITTAL 07-28-2016 RE-SUBMITTAL 11-14-2016 RE-SUBMITTAL 02-13-2017 ---------------- Date: 02/23/16 Project No.: 100611 Task 019.007 Sheet Titles: Title Sheet Sheet No.: T-1 I I /.... I -J Site Plan SCALE: 1' = 50'-Q" I ' I /....-'\\ 0 l1l "C .£ ai 0 KEYNOTES: IT] (E) ELLERY RESERVOIR WATER TANK ~ @] I±] @] [ID m [ID [ID (E) ASPHALT ROAD (E) ASPHALT DRIVEWAY (E) 15'-0' RIGHT OF WAY EASEMENT (E) 8' UTIL. ESMT ., SDG&E (E) 6' UTIL. ESMT., SDG&E (E) WATER TANK SERVICE ROAD EDGE (P) PROPOSEOCMU RETAINING WALL 14' MAX. HEIGHT (P) PROPOSED 10'x24' PREFABRICATED EQUIPMENT SHELTER ON A POURED-IN-PLACE CONCRETE PAD [g (P) PROPOSED GENERATOR WITHIN NOISE CANCELLATIO INCLOSURE ON A POURED-IN-PLACE CONCRETE PAD [j] (P) PROPOSED 1 O'X30' SERVICE PARKING SPACE (A.O. PAVING) ~ (P) PROPOSED 60' HIGH FAUX MONO-EUCALYPTUS TREE [1] 1H (El UTILITY UNIT (PROPOSED ELECTRICAL P.0.C.) (P) ADD TO (E) "H' FRAME FOR PROPOSED 200AMP ELECTRICAL METER [§ (P) lJTILITY TRENCH W/ 3' CONDUIT (ELECTRICAL) TO LEASE AREA, PRELIMINARY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUC'TION (TRENCH LENGTH = ±290'-0') LEGEND: (E) INDICATES EXISTING (P) INDICATES PROPOSED INDICATES (E) CHAIN-LINK FENCE D INDICATES (E) A.C. PAVING INDICATES (N) A.C. PAVING ..... (E) FIRE HYDRANTS =-=-: (N) RETAINING WALL GENERAL NOTES: 1. THE PROPERTY BOUNDARY LINES SHOWN ON THIS DRAWING ARE FOR REFERENCE ONLY. A BOUNDARY SURVEY WAS NOT PERFORMED. 2. FIELD VERIFY AND LOCATE EXISTING UNDERGROUND WATER OR DRAIN LINES. HAND TRENCH AND DEEPEN AS REQUIRED IN FIELD WHERE CONDUITS NEED TO CROSS EXISTING WATER OR DRAIN LINES. PROVIDE CONCRETE ENCASEMENT OF CONDUITS MINIMUM 5'-0' EACH SIDE (TYPICAL) (ENCROACHMENT PERMIT REQUIRED) CUP16-07 • I lll)NIOONil~ IH XJ WlmC0,0\ 02105 fiOIQIQ41)1)WolOMJlQ1 Drawn By: Checked By: J.M. LS. No. Dote Issue Description SUBMITTAL 07-28-2016 RE-SUBMITTAL 11-14-2016 RE-SUBMITTAL 02-13-2017 02/23/16 Project No.: >------------------< 100611 Task 019.007 Sheet Titles: GRAPHIC SCALE I KEY PLAN: Site Plan Sheet No.: so· 100· ,so· SCALE: 1" = 50'-0" (1 :600) A-0 ) \ \ Enlarged Site PI an SCALE: 1' = 20'-0' KEYNOTES: [j] (E) ELLERY RESERVOIR WATER TANK ~ (E) WATER TANK ASPHALT SERVICE ROAD @] (E) CROWN CASTLE LEASED GROUND SPACE I±] (E) CROWN CASTLE CELLULAR FAUX TREE @] (E) CONCRETE PAD [ID (E) 8' UTIL. ESMT., SDG&E m (E) TELEPHONE & ELECTRICAL LINES TO EXISTING CELLULAR SITE [ID (E) i 5'-0' RIGHT OF WAY EASEMENT [ID (N) UTILITY TRENCH (ELECTRICAL) TO LEASE AREA, PRELIMINARY UTILITY ROlJTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUCTION (TRENCH LENGTH = ±290'-0') [jg (P) ELECTRICAL SWITCH GEAR [j] (E) UTILITY UNIT (PROPOSED ELECTRICAL P.O.C) [jjj (E) NEW RETAINING WALL 14' MAX. HEIGHT LEGEND: (E) INDICATES EXISTING (P) INDICATES PROPOSED INDICATES (E) CHAIN-LINK FENCE D INDICATES (E) A.O. PAVING INDICATES (N) A.O. PAVING INDICATES (E) TREES =-=-: (N) RETAINING WALL GENERAL NOTES: 1. THE PAOPEAlY BOUNDARY LINES SHOWN ON THIS DRAWING ARE FOR REFERENCE ONLY. A BOUNDARY SURVEY WAS NOT PERFORMED. 2. FIELD VERIFY AND LOCATE EXISTING UNDERGROUND WATER OR DRAIN LINES. HAND TRENCH AND DEEPEN AS REQUIRED IN FIELD WHERE CONDUITS NEED TO CROSS EXISTING WATER OR DRAIN LINES. PROVIDE CONCRETE ENCASEMENT OF CONDUITS MINIMUM 5'--0' EACH SIDE (TYPICAL) (ENCROACHMENT PERMIT REQUIRED) GRAPHIC SCALE I KEY PLAN: 4' 8' SCALE: 1/4' = 1'--0' 12' (1:48) CUP 16-07 • I lll)NIOONil~ IH XJ wimco.0102105 fiOIQIQ41)1)WolOMJlQ1 Drawn By: Checked By: J.M. LS. No. Dote Issue Description SUBMITTAL 07-28-2016 RE-SUBMITTAL 11-14-2016 RE-SUBMITTAL 02-13-2017 Project No.: 100611 Task 019.007 Sheet Titles: Sheet No.: Enlarged Site Plan A-1 Enlarged Are a PI an SCALE: 118' = 1'-0" KEYNOTES: IT] (E) ELLERY RESERVOIR WATER TANK ~ @] I±] @] (E) ASPHALT ROAD (E) 15'-0' RIGHT OF WAY EASEMENT (E) 8' UTIL. ESMT., SDG&E (E) TELEPHONE & ELECTRICAL LINES TO EXISTING CELLULAR SITE [§J (El CROWN CASTLE CELLULAR FAUX TREE m [ID [ID [jg (E) CONCRETE PAD (E) CROWN CASTLE LEASED GROUND SPACE (P) PROPOSED CMU RETAINING WALL (14' MAX. HEIGHl) (P) PROPOSED 10'x24' PREFABRICATED EQUIPMENT SHELTER ON A POURED-IN-PLACE CONCRETE PAD [1j (P) PROPOSED GENERATOR WITHIN NOISE CANCELL.ATIO INCLOSURE ON A POURED-IN-PLACE CONCRETE PAD ~ (P) PROPOSED 30'x1 O' SERVICE PARKING SPACE (A.C. PAVING) ~ (P) PROPOSED ANTENNAS MOUNTED TO (N) 60' HIGH FAUX MONO-EUCALYPTUS TREE, TYP. SEE NA2. 1 FOR ADDmONAL INFO. [HI (E) TREE TO BE DEMOLISHED AND REPLACED PEA LANDSCAPE DRAWINGS [§ (P) BOLLARDS [ITj [ii (P) CABLE BRIDGE (P) lJTILITY TRENCH W/ 3' CONDUIT (ELECTRICAL) TO LEASE AREA, PAELIMINAAY UTILITY ROUTE TO BE FIELD VERIFIED AND ADJUSTED ACCORDINGLY DURING CONSTRUC'TION (TRENCH LENGTH = ±290'-0') [ill (P) ELECTRICAL SWITCH GEAR Im ~ ~ ~ (E) WOOD FENCE 6' H. (P) 24' WIDE CONCRETE BROW DITCH (P) BROW DITCH DISCHARGE AT GRADE LEVEL REMOVE (E) PINE TREE (P-2) AND REPLACE WITH NEW 24' BOX TREE -PEA ARBOAIST RECOMMENDATIONS LEGEND: (E) INDICATES EXISTING (P) INDICATES PROPOSED INDICATES (E) SOLID WOOD FENCE INDICATES (E) CHAIN-LINK FENCE INDICATES (N) AC. PAVING D INDICATES (E) A.C. PAVING TOP INDICATES TOP ELEVATION BOT INDICATES BOTTOM ELEVATION INDICATES (E) TREES INDICATES LIMITS OF GRADING =-=-: (N) RETAINING WALL GENERAL NOTES: 1. TOTAL PROPOSED DISTURBED AREA: TOTAL PROPOSED IMPERVIOUS AREA: TOTAL PROPOSED LANDSCAPE AREA: EARTHWORK QUANTITY: 1,400 SO. FT. 1,400 SO. FT. 937 SQ. FT. 165CY. 2. THE PROPERTY BOUNDARY LINES SHOWN ON THIS DRAWING ARE FOR REFERENCE ONLY. A BOUNDARY SURVEY WAS NOT PERFORMED. 3. FIELD VERIFY AND LOCATE EXISTING UNDEAGAOUND WATER OR DRAIN LINES. HAND TRENCH AND DEEPEN AS REQUIRED IN FIELD WHERE CONDUITS NEED TO CROSS EXISTING WATER OR DRAIN LINES. PROVIDE CONCRETE ENCASEMENT OF CONDUITS MINIMUM 5'-0' EACH SIDE (TYPICAL) (ENCROACHMENT PERMIT REQUIRED) GRAPHIC SCALE I KEY PLAN: 8' 16' SCALE: 1/B" = 1'-0' 24' (1:96) CUP 16-07 • I lll)NIOONil~ IH XJ wimco.0102105 fiOIQIQ41)1)WolOMJlQ1 Drawn By: Checked By: J.M. LS. No. Dote Issue Description SUBMITTAL 07-28-2016 RE-SUBMITTAL 11-14-2016 RE-SUBMITTAL 02-13-2017 Project No.: 100611 Task 019.007 Sheet Titles: Sheet No.: Enlarged Area Plan A-2 g TYP. 'r -~ NOATI-i ELEVATION WEST ELEVATION Equipment Elevations SCALE: 1/B' • 1'-0" ·1 "' Equipment Section SCALE: 1/8' = 1'-0" SOUTI-t ELEVATION EAST ELEVATION ,._,. I ' ;,, Enlarged SCALE: 1/4" = 1'-0' Equipment 3'-0' CLR. -----...... ,,,, '\------{§] \ I I I I Shelter FI o or PI an KEYNOTES: IT] 4" PRE-CAST CONCRETE WALLS ~ @] I±] @] [ID WALL MOUNTED AC UNITS CONCRETE LANDING OVERHEAD COAX CABLE ICE BRIDGE 60'-0" HIGH MONOEUCAL YPTUS OUTLINE OF PROPOSED MONOEUCAL YPTUS CANOPY (SHOWN DASHED) [I] 24' WIDE CONCRETE BROW DITCH (3' CONCRETE W/ 1-1/2" X 1-1/2' 17 GAGE STUCCO NETTING) [I) (P) 4' MICROWAVE ANTENNA MOUNTED ON MONO-EUCALYPTUS TREE (CONCEAL WITH FOLIAGE AF TRANSPARENT SCREENJSQCKS) ~ (P) ONMI ANTENNAS (3 QTY.) MOUNTED ON MONO-EUCALYPTUS TREE (PAINTED TO MATCH FOLIAGE) [g (P) RECEIVEONLYONMI ANTENNA (1 QTY.) MOUNTED ON MONO-EUCALYPTUS TREE (PAINTED TO MATCH FOLIAGE) [1j (P) 1' X 1' -CITY OF CARLSBAD $CADA ANTENNA ~ (P) CITY OF CARLSBAD VHF OMNI TRANSMIT ANTENNA MOUNTED ON MONO-EUCALYPTUS TREE (PAINTED TO MATCH FOLIAGE) LEGEND: (E) INDICATES EXISTING (P) INDICATES PROPOSED INDICATES (E) CHAIN-LINK FENCE INDICATES (E) A.C. PAVING GENERAL NOTES: 1. THE PROPERlY BOUNDARY LINES SHOWN ON THIS DRAWING AAE FOR REFERENCE ONLY. A BOUNDARY SURVEY WAS NOT PERFORMED. 2. FIELD VERIFY AND LOCATE EXISTING UNDERGROUND WATER OR DRAIN LINES. HAND TRENCH AND DEEPEN AS REQUIRED IN FIELD WHERE CONDUITS NEED TO CROSS EXISTING WATER OR DRAIN LINES. PROVIDE CONCRETE ENCASEMENT OF CONDUITS MINIMUM 5'-0' EACH SIDE (TYPICAL) (ENCROACHMENT PERMIT REQUIRED) 3. OMNI ANTENNAS SHALL BE PAINTED TO MATCH THE COLOR OF THE MONO-EUCALYPTUS TREE. GRAPHIC SCALE I KEY PLAN: 4' 8' SCALE: 1/4" = 1'-0' 12' (1:48) CUP 16-07 • I lll)NIOONil~ IH XJ wimco.0102105 fiOIQIQ41)1)WolOMJlQ1 Drawn By: Checked By: J.M. LS. No. Dote Issue Description SUBMITTAL 07-28-2016 RE-SUBMITTAL 11-14-2016 RE-SUBMITTAL 02-13-2017 Project No.: 100611 Task 019.007 Sheet Titles: Enlarged Equipment Floor Plan/ Elevations Shee\No A-2.1 KEYNOTES: DJ (E) ELLERY WATER TANK [lj (P) MONOPOLE EUCALYPTUS [lj (E) RESIDENTIAL HOUSE @J (P) CMU RETAINING WALL ffij (P) EQUIPMENT SHELTER ffij (E) TREE [zJ (E) TREE (LOCATED ON ADJACENT PROPERTY) ffij (P) LINE OF SIGHT SECTION SCALE: 1" = 25'-0" C A i l I i NOTTO SCALE NORTH JANIES WAY I CUP 16-07 • )515 [WlAll!l,\lH 400 \An DltGQCA 02108 1[[010l04/515'/Ml0l0!/50l Drawn By: Checked By: J.M. L.S. No. Dote Issue Description SUBMITIAL 07-28-2016 RE-SUBMITIAL 11-14-2016 RE-SUBMITIAL 02-13-2017 Project No.: 100611 Task 019.007 Sheet Titles: Sheet No.: Site Sections A-3 356.00' T.O.T. EAST ELEVATION SCALE: 1,a• = 1'--0' @ ~,~~~·-0· ELEVATION ~ ~ ___filQQ'___,j, ~ KEYNOTES: IT] (E) ELLERY RESERVOIR WATER TANK ~ @] I±] @] (E) ASPHALT ROAD (E) CHAIN-LINK FENCE (P) PROPOSED CMU RETAINING WAll (P) PROPOSED 10'x24' PREFABRICATED EQUIPMENT SHELTER ON A POURED-IN-PLACE CONCRETE PAD (240 SQ.FT.) [ID (P) PROPOSED GENERATOR WITHIN NOISE CANCELLATIO INCLOSURE ON A POURED-IN-PLACE CONCRETE PAD [I] (P) OMNI ANTENNAS (4 Q1Y.) & RECEIVE ONLY OMNI ANTENNA (2 QTY.) MOUNTED TO (N) MONO-EUCALYPTUS TREE (PAINTED TO MATCH FOLIAGE) [I) (P) BOLLARDS [ID [jg [j] (E) TREE (E) SOLID WOOD FENCE (P) 4' MICROWAVE ANTENNA MOUNTED ON MONO-EUCALYPTUS TREE (CONCEAL WITH FOLIAGE RF TRANSPARENT SCAEEN,SOCKS) [gj (P) 1' X 1' -CITY OF CARLSBAD $CADA ANTENNA LEGEND: (E) INDICATES EXISTING (P) INDICATES PROPOSED GENERAL NOTES: CUP 16-07 • I lll)NIOONil~ IH XJ WlmC0,0\ 02105 fiOIQIQ41)1)WolOMJlQ1 Drawn By: Checked By: J.M. LS. No. Dote Issue Description SUBMITTAL 07-28-2016 RE-SUBMITTAL 11-14-2016 e-------------------, RE-SUBMITTAL 02-13-2017 GRAPHIC SCALE I KEY PLAN: 8' 16' 24' SCALE: 1/B" = 1'--0' (1:96) Project No.: 100611 Task 019.007 Sheet Titles: Sheet No.: Exterior Elevations A-4 EXISTING NORTH ELEVATION SCALE: 1/8" = 1'--0' "' 345.00'_ ~9 ',: r-J" I I I I I ' .., BOT OF ONMI ANTENNA PROPOSED CMU WALL DASHED FOR CLARITY _ __ t i~-' +-p="=========, PROPOSED :·1 '" ,- ' SOUTH ELEVATION SCALE: 1/B" = 1'--0' ' l<l 1 2 1 2 EXISTING ~ ----39f~.~: + i~P 06r~:ru,k~~ '---- ' ':, 343.00' A. -------r.o:w.-v KEYNOTES: IT] (E)CMUWALL [g] (E) CROWN CASTLE LEASED GROUND SPACE ~ (P) PROPOSED CMU RETAINING WALL [!) (P) PROPOSED 10'x24' PREFABRICATED EQUIPMENT SHEL TEA ON A POURED-IN-PLACE CONCRETE PAO (240 SQ.Ff.) [fil (P) PROPOSED GENERATOR WITHIN NOISE CANCELLATIO INCLOSUAE ON A POURED-IN-PLACE CONCRETE PAD ffiJ (P) PROPOSED 30'x1 O' SERVICE PARKING SPACE (A.C. PAVING) [I] (P) OMNI ANTENNAS (4 QlY.) & RECEIVE ONLY OMNI ANTENNA (2 QTY.) MOUNTED TO (N) MONO-EUCALYPTUS TREE (PAINTED TO MATCH FOLIAGE) [ID (E) SOLID WOOD FENCE [ID (P) BOLLARDS [g (P) CABLE BRIDGE [j] (E) CHAIN-LINK FENCE ~ (E)TAEE ~ (P) GENERATOR ENCLOSURE [HI (P) 4' MICROWAVE ANTENNA MOUNTED ON MONO-EUCALYPTUS TREE (CONCEAL WITH FOLIAGE RF TRANSPARENT SCREEN,SOCKS) ff§ (P) 1' X 1' -CITY OF CARLSBAD SCADA ANTENNA ll1l (E) TREE -ALEPPO PINE (P-1) ON ADJACENT RESIDENTIAL SITE [1I (E) TREE -ALEPPO PINE (P-2) ON ADJACENT RESIDENTIAL SITE LEGEND: (E) INDICATES EXISTING (P) INDICATES PROPOSED GENERAL NOTES: 1. CUP 16-07 • I lll)NIOONil~ IH XJ wimco.lA 02105 fiOIQIQ41)1)WolOMJlQ1 Drawn By: Checked By: J.M. LS. No. Dote Issue Description SUBMITTAL 07-28-2016 RE-SUBMITTAL 11-14-2016 e-------------------, RE-SUBMITTAL 02-13-2017 GRAPHIC SCALE I KEY PLAN: 8' 16' SCALE: 1/B" = 1'-0' 24' (1:96) Project No.: 100611 Task 019.007 Sheet Titles: Sheet No.: Exterior Elevations A-5 \ \' A EXISTING RESIDENCES VT \ EXl~ING RESIDENCES ,/ \\ \ \ \ \ L \ \ ''\ \ ' \\ "~\ \ \ J \ \ I' \__ \ \ \ \ \ I\ \ ,2 \ r EXISTING 8' WIDE UTILITY EASEMENT S~&E I, \ I 1 \ C EXISTING WATER TANK ~ ( t I L >-- I; \ ( \ '\-\' ) -Ii~, 1 ~XISTING / t' RESIDENC_?S // 'I I , I I I I I I EXISTING \ RESIDENCES -f J 20' 40' ~ I ' l X I I I I I 50'• ~ SCALE: i' = 20'-0' (1:240) EXISTING TREES SYMBOL BOTANICAL NAME COMMON NAME ACALON ACACIA LONGIFOLIA SYDNEY GOLDEN WATTLE EUCCOR EUCALYPTUS CORN UTA YATE EUC MAC EUCALYPTUS MACULATA SPOTTED GUM EUCSID EUCALYPTUS SIDEROXYLON RED IRONBARK FRAUHD FRAXINUS UHDEI EVERGREEN ASH JUN TOR JUNIPERUS TOLUROSA HOU. YWOOD JUNIPER PIN HAL PINUS HALEPENSIS ALEPPO PINE DROUGHT TOLERANT PLANT SCHEDULE 0 12'•15' HtGH SCREENING TREES SUCH AS: 100% • 24-BOX MIN. JUNIPERUS CHINENSIS 'KAIZUKA' 1fOLL YWOOO JUNIPER' WUCOLS PLANT FACTOR 0.2 WUCOLS PLANT 0 12'-15' HIGH SCREENING SHRUBS SUCH AS:100% • 15 GAL. MIN. FACTOR CEANOTHUS 'RAY HARTMAN' "RAY HARTMAN WILD LILAC" 0.2 HETEROMEI.ES ARBUTIFOI.IA "TOYON" 0.2 MALOSMA lAURINA 1.AUREL SUMAC" 0.2 WUCOLSPLANT 6" HIGH GROUND COVER SUCH AS: 100%• FLATS@XO.C. FACTOR W Delosp&nna'Alba'-~iteTralllnglcePlanl 0.2 IRRIGATION NOTES 2.11-E~TDIS'ISIEM'MJ.IECESGID'MJHOEPONTCFCXHECTDITOll-EE)Sft(,Gl<lEV,llVE.a:tAlBl.~ """""s,sie, l TlE~TOIIS'ISIEM'MJ.IECD.f'R:E)CFNMJ.W.,PIESS.IERBl.J.AlED, I.DNRDNll.lBlRSATOOil'RPCHDR.JM". 4.~TDIS'r.iJBAS'MJ.UJI..IZE>H)cx:tfEl"T0TlEE)l5JN3,6'TTBn'BILX-lf>mGATDICCNJRl..lSVWSi!U.UTI.IZEAP>fl """' 5. illl.fEl.R:DmGATDlsYSIEM39WJ.IENl'CfNIT(:,a.s;JRCIU.VCXlfflQJED,NOCESGID10PR:MEWATERTO.-U.fBJ.RD PIHlltGSlOPMNTANlliM N Al-9Lll-fl',OOEAS&IBTHITCOOTOl.illl.mGATDl~CEV(2l9-WJ.r.t:El"TI£fm..RM:NTS SETNMNS5TN(W().f,SJJf£J(X,((l2.3)14.~ff«YITOll~N0~5Tlt{)!i{}'./illSPPHQ.fRIEPmNSTi!UB'.:lN TlE~M.STIXXl.M:NTAOOTR8JTDlt.NR)MJ'(l.ONCIJ,!RlffiCF0.65CRI-DERLE;N;nEPRJRXXl.lEN:DN"8N£1tt '"®" 6. #E/>S~~"JB,j(1~FEErNWDIHNNtf~9WLIEIR;ATB)WJHa..B:l.WN:EIR:ATDICROTlERr.EMISTli\T f'Rll.Wt()A.N:fFCR<M:RSPPAV. 1. Am.Ea'FNllNPECl10l.TIEPBMTN'fl.DNTl.l.6TPR:M:Ell-ECMMRa'TH:FKf'ERIY'MIHA~TECf~ Cffi'IFK:ATECFNST.il..LATOl.lfflATOll9:l£U.E.NOASOEUECF~NORO.TOIIWHTeWa. LANDSCAPE NOTES PROJECTPI.ANTINGAREA:3,069SF ALL PLANTING AREAS Will. BE COVERED 'MTH MULCH TO A MINMJM DEPTH OF 3 INCHES. ALL Pl.ANT MATERW. SHALL BE WJNTAINED IN A HEAL THY ANO OISEASE·FREE GROWING CONOmON AT ALL TIES. ALL REQUIRED Pl.ANTING AREAS SIW.1 BE MAINTAINED FREE OF WEEDS, OEBRIS AND LITTER. THE LONG lERM WJNTENANCE OF llE PROJECT SIW.1 BE THE RESPONSIBl.lTY OF THE OWNER DISEASED OR DEAi) Pl.ANT W.TERIAL SHALL BE SAT1SFACT0RIL Y TREATED OR REPLACED PER THE CONJITIONS OF THE PERMIT. 14CORPORATE COMPOST AT A RATE OF ATLEASTFOUR CUBIC YARDS PER 1,000 SOOARE FEET TOA DEPTH OF SIX t4CHES INTO LANDSOff: AREA (l,t,ILESS CONTRAINDICATED BY A SOIL TEST). PRESCRIPTIVE COMPLIANCE THIS PROJECT WILL CONFORM TO THE PRESCRIPTIVE REQUIREMENTS SET FORTH IN APPENDIX D OF THE CITY OF CARLSBAD LANDSCAPE MANUAL AS A COMPLIANCE OPTION TO THE WATER EFFICIENT LANDSCAPE ORDINANCE FOR PROJECTS OF LESS THAN 2.500 SQUARE FEET. COMPLIANCE WITH THE FOU.OWING ITEMS IS MANDATORY: 1. FOR N()t1U'!ESIDENT1AL AREAS, INSTALL CLIMATE ADAPTED PLANTS THAT REQUIRE OCCASIONAL, LITnE OR NO SUMMER WATER (AVERAGE WUCOL.S PLANT FACTOR 0.3) FOR 100% OF THE Pl.ANT AREA EXCLUDING EDIBLES ANO AREAS USING RECYCLED WATER. 2. A MINIMUM THREE INCH (3") LAYER OF MULCH SHAU. BE APPLIED ON ALL EXPOSED SOIL SURFACES OF PLANTING AREAS EXCEPT IN 1\JRF AREAS, CREEPING OR ROOTING GROUNOCOVERS, OR OIRECT SEEOING APPLICATIONS WHERE MULCH IS CONTRAINDICATED. 3. ALITOMATIC IRRIGATION CONTROLLERS ARE REQUIRED AND MUST USE EVAPOTRANSPIRATION OR SOIL MOISTURE SENSOR DATA AND llTILIZE A RAIN SENSOR. 4. IRRIGATION CONTROLLERS SHAU. BE OF A TYPE WHICH DOES NOT LOSE PROGRAMMING DATA IN THE EVENT THE PRIMARY POWER SOURCE IS INTERRUPTED. S. PRESSURE REGULATORS SHAU. BE INSTALLED ON THE IRRIGATION SYSTEM TO ENSURE THE DYNAMIC PRESSURE OF THE SYSTEM IS WITHIN THE MANUFACTURERS RECOMMENDEO PRESSURE RANGE. 6. MANUAL SHIJT-OFFVALVES {SUCH AS A GATE VALVE, BALL VALVE, OR BUTTERFLY VALVE) SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO THE POINT OF CONNECTION OF THE WATER SUPPLY. 7. ALL IRRIGATION EMISSION DEVICES MUST MEET THE REQUIREMENTS SET IN THE ANSI STANOARO, ASABEJICC 802-2014. "GLANDSCAPE IRRIGATION SPRINKLER AND EMITTER STANDARD."H ALL SPRINKLER HEADS INSTALLED IN THE LANDSCAPE MUST DOCUMENT A OISTRIBUTION UNIFORMITY LOW QUARTER OF o.65 OR HIGHER USING THE PROTOCOL OEFINEO IN ASABE/ICC 802•2014. 8. AREAS LESS THAfll TEN (10) FEET IN WIOTH IN ANY DIRECTION SHAU. BE IRRIGATED WITH SUBSURFACE IRRIGATION OR OTHER MEAffS THAT PRODUCES f'fO RUf'fOFF OR OVERSPRAY. B. AT THE TIME OF FINAL INSPECTION, THE PERMIT APPLICANT MUST PROVIDE THE OWNER OF THE PROPERTY WITH A CERTIFICATE OF COMPLETION, CERTIFICATE OF INSTALLATION, IRRIGATION SCHEDULE ANO A SCHEDULE OF LANDSCAPE AND IRRIGATION MAINTENANCE. • ' 7515 Metropolitan Drive. Suite 400 San Diego, CA 92108 Tel: (619) 294-7515 Fox: (619) 294-7592 www.sillman'Might.com Drown By: Checked By: JJ,4. R.8. No. Dole Issue Description 01 /30/17 Project No.: 100611 Task 019.007 Sheet Titles: LANDSCAPE CONCEPT PLAN Sheet No.: L-1