Loading...
HomeMy WebLinkAboutEA 16-06; Carlsbad Boulevard CMP; Planning CommissionCONSTRUCTION PLANS FOR CMP REPLACEMENT PROGRAM 'R"" . :r""" r ;)' .. ~. . . t:: \."'' r.: QCT 0 4 20i6 -.,..., .,. ·~ ;<-..-:·.)"' (CARLSBAD BLVD NORTH OF ISLAND WAY) PROJECT SITE~ l® _111111'1 ..... CIII.,_JIU..._ VICINITY MAP NO SCALE SHEET INDEX 1 TITLE SHEET VICINilY MAP & LOCATION MAP 2 NOTES ABBREVIATIONS LEGEND & DETAILS 3 STORM DRAIN & SLOPE STABILIZATION IMPROVEMENTS -PLAN & PROFILE 4 STORM DRAIN IMPROVEMENTS-PLAN & PROFILE REFERENCE DRAWINGS DWG. 469-9 SOUTH CARLSBAD STATE BEACH PUMP STATION NO.3 FORCE MAIN & SANITARY SEWER-SITE PLAN MAP 13253 CARLSBAD TRACT NO. 93-10 CARLSBAD SEAPOINTE RESORT CALL811 ATLEASTTWODAYS BEFORE YOU DIG UNDERGROUNDSERVICi:AiiRlOfSOJTHERNCAUFORNIA PROJECT NO. 6607 CITY OF CARLSBAD CARLSBAD, CALIFORNIA CITY COUNCIL MATI HALL-MAYOR KEITH BLACKBURN -MAYOR PROTEM LORRAINE M. WOOD-COUNCIL MEMBER MARK PACKARD-COUNCIL MEMBER MICHAEL SCHUMACHER-COUNCIL MEMBER TBD-PUBLIC WORKS DIRECTOR SEPTEMBER 2016 PROJECT SITE ED LOC~,~~~o~ MAP DECLARATION OF RESPONSIBLE CHARGE I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. FIRM: AECOM TECHNICAL SERVICES, INC ADDRESS: 401 W. A STREET SUITE 1200 CITY, ST.: SAN DIEGO, CALIFORNIA 92101 TELEPHONE: 619-610-7600 BY: JOSEPH LONG, PE DATE: ------ R.C.E. NO.: _ _;C;.:;5_;.43:c2....:9 _______ _ REGISTRATION EXPIRATION DATE: 12/31/17 1----~--~------------------+-~---r--+--1~ CITY OF CARLSBAD ISHEE~! L___!_j ENGINEERING DEPARTMENT 4 I I I I I I I II IMPROVEMENT PLANS FOR: I " I CMP REPLACEMENT PROGRAM (CARLSBAD BLVD) "AS BUILT .-=--. TITLE SHEET, VICINITY MAP A: COM DESIGN+ CONSULTING SERVICES-AMERICAS 1 COLUMBIA PLACE 401 W. A STREET, SUITE 1200 SAN DIEGO, CA. 92101 TEl: 619.610.7600 www.aecom.com RCE---EXP. ___ _ REVIEWED BY: INSPECTOR DATE DATE DATE I INITIAl ENGINEER <F WORK REVISION DESCRIPTlON & LOCATION MAP APPROVED: lBD DATE INITIAL GENERAL NOTES 1. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND TITLE SHEET. 2. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY CONTRACTOR PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 3. CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 4. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE ENGINEER THE DESIGN OF SHORING, BRACING SLOPE OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 5. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATIENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 6. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES (ABOVEGROUND AND UNDERGROUND) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO PERMIT THE REVISIONS OF THE CONSTRUCTION PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 7. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST TWO FULL WORKING DAYS PRIOR TO STARTING CONSTRUCTION NEAR THEIR FACILITIES AND SHALL COORDINATE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT SDG&E AT&T TIME WARNER CABLE CITY OF CARLSBAD (STREETS AND STORM DRAIN) CITY OF CARLSBAD (SEWER, WATER & RECLAIMED WATER) {800)42Z-4133 {800)660~7343 I800)B9Z~0123 I760)43B~7741 {760)434~29BO I760)438~272Z 8. ITEMS THAT ARE NOT IDENTIFIED AS "TO BE REMOVED AND DISPOSED" SHALL BE PROTECTED-IN-PLACE. 9. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT All TIMES DURING CONSTRUCTION. 10. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK ZONE DURING CONSTRUCTION, OPERATIONS SHALL CEASE IMMEDIATELY, AND THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER. OPERATIONS SHALL NOT RESTART UNTIL THE CONTRACTOR HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO so. 11. ALL OPERATIONS EXCEPT TRAFFIC CONTROL CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00A.M. AND 4:00P.M., MONDAYTHRU FRIDAY. 12 All OFF-SITE HAUL ROUTES SHALL BE SUBMITIED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE HAULING. 13. UNLESS OTHERWISE INDICATED, SUBSURFACE UTILITY DATA IS DEPICTED TO LEVEL CAS DEFINED IN "STANDARD GUIDELINE FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA" CI/ASCE 38-02. LEVEL C INCLUDES SURVEYING SURFACE UTILITY FEATURES AND CORRELATING APPLICABLE UTILITY RECORDS TO THE SURVEYED FEATURES. 14. SECTION 4216/4217 OF THE GOVERNMENT CODE REQUIRES THAT A DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A "PERMIT TO EXCAVATE" WILL BE VALID. FOR DIG ALERT ID NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 811 TWO FULL WORKING DAYS BEFORE YOU DIG. BASIS OF COORDINATES CLSB-112 N 2003815.193' E 6236371.586' ELEV 14l.B45' {NAVDB8) RECORD OF SURVEY 17271 NAD 83 (199~.~L tt'ULH} WELL MONUMENT STAMPED "LS 3189" IN CENTER OF BULB CUL-DE-SAC AT THE NORTH END OF SALISBURY DRIVE. BENCHMARK CLSB-126 ELEV 76.767' {NAVD 8B) RECORD OF SURVEY 17271 2" IRON PIPE AND DISC STAMPED "CLSB-126 l.S. 6215" 15 FEET OFF EAST SHOULDER OF EL CAMINO REAL 100 FEET SOUTH OF INTERSECTION WITH TAMARACK AVE. NOTES: CLSB-126 N 2001291.609' E 6236635.227' £LEV 76.767' (NAVD 88) RECORD OF SURVEY 17271 2" IRON PIPE AND DISC STAMPED "CLSB-126 l.S. 6215" 15 FEET OFF EAST SHOULDER OF EL CAMINO REAL100 FEET SOUTH OF INTERSECTION WITH TAMARACK AVE. PROPERTY LINES, CENTERLINE$, AND EXISTING EASEMENT LINES SHOWN HEREON WERE ESTABLISHED FROM AVAILABLE RECORD MAPS AND ASSESSOR'S MAPS. NO TITLE REPORTS WERE REVIEWED FOR THIS PROJECT. SELECT RECORD MONUMENTS WERE TIED INTO THE PROJECT COORDINATE SYSTEM TO ORIENTATE RECORD MAPS. BEARINGS AND DISTANCES TAKEN FROM THIS DRAWING REPRESENT A BEST FIT COMPILATION OF RECORD DATA. THESE PROPERTY LINES AND EXISTING EASEMENT LINES ARE INTENDED TO BE USED FOR A GRAPHIC REPRESENTATION ONLY. 1® __ ........ CII..,_Jlllll..., CALL 811 ATLE>\STrNODAYS BHORE~OUDIG UNDE%ROUNDSERVIC£AlER10FSOUTHERNCAUFORNIA GENERAL TRAFFIC CONTROL NOTES 1. AT LEAST ONE PERSON SHALL BE ASSIGNED TO FULL TIME MAINTENANCE OF TRAFFIC CONTROL DEVICES ON ALL NIGHT LANE CLOSURES. 2. ALL WARNING SIGNS FOR NIGHT LANE CLOSURES SHALL BE ILLUMINATED REFLECTORIZED AS SPECIFIED IN THE SPECIFICATIONS. 3. ALL ADVANCE WARNING SIGN INSTALLATIONS SHALL BE EQUIPPED WITH FLAGS FOR DAYTIME CLOSURES OF ALL MAJOR AND PRIME ARTERIALS. FLASHING BEACONS SHALL BE USED DURING NIGHT LANE CLOSURES. 4. A G20-2 "END ROAD WORK" SIGN SHALL BE PLACED AT THE END OF THE LANE CLOSURE UNLESS THE END OF THE WORK AREA IS OBVIOUS, OR ENDS WITHIN A LARGER PROJECT LIMITS. 5. ALL CONES USED FOR NIGHT LANE CLOSURES SHALL BE ILLUMINATED TRAFFIC CONES OR FITTED WITH 13" REFLECTIVE SLEEVES. 6. FLASHING ARROW SIGNS SHALL BE USED PER THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA MUTCD, LATEST EDITION) SILENT TYPE SHALL BE USED IN RESIDENTIAL AREAS. 7. THE MAXIMUM SPACING BETWEEN CONES IN A TAPER OR A TANGENT SHALL BE APPROXIMATELY 10 FEET. 8. ADDITIONAL ADVANCE FLAGGERS SHALL BE REQUIRED WHEN TRAFFIC QUEUES DEVELOP. FLAGGER STATIONS FOR WORK AT NIGHT SHALL BE ILLUMINATED AS NOTED IN SECTION 6G.20 OF THE MUTCD. 9. PLACE C30 (CA) "LANE CLOSED" SIGN AT 500'-1000' INTERVALS THROUGHOUT EXTENDED WORK AREAS. 10. ALL REQUIRED SIGNS THAT ARE TO BE LEFT IN PLACE OVER A WEEKEND OR HOLIDAY SHALL BE POST MOUNTED USING SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SDRSD M-45. 11. CONSTRUCTION AREA TRAFFIC CONTROL DEVICES SHALL MEET THE PROVISIONS OF SECTION 12 OF THE MOST RECENT EDITION OF THE CALTRANS STANDARD SPECIFICATIONS. EXCAVATION NOTES 1. ALL EXISTING STRUCTURES TO BE DEMOLISHED SHALL BE REMOVED PRIOR TO COMMENCEMENT OF IMPROVEMENT WORK-ANY EXCEPTIONS SHALL REQUIRE WRITIEN PERMISSION FROM THE DISTRICT ENGINEER. 2. THE CONTRACTOR SHALL OBTAIN AN EXCAVATION PERMIT FROM THE DIVISION OF INDUSTRIAL SA FEn' BEFORE ANY EXCAVATION AND SHALL PROVIDE PROOF OF OSHA NOTIFICATION AND SHALL ADHERE TO All PROVISIONS OF THE STATE CONSTRUCTION SAFEn' ORDERS. SIGNING AND STRIPING NOTES 1. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF All SIGNING AND STRIPING THAT WAS REMOVED OR DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITIES. 2. All SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST VERSION), THE CAL TRANS STANDARD PLANS AND SPECIFICATIONS (LATEST VERSION), THESE PLANS AND THE SPECIAL PROVISIONS. 3. All SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE, PRIOR TO INSTALLATION. 4. ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE PRIOR TO ANY CHANGE IN THE FIELD. 5. ALL STRIPING SHALL BE REFLECTIVE PER CAL TRANS SPECIFICATIONS. STRIPING SHALL BE REPAINTED TWO WEEKS AFTER INITIAL PAINTING. 6. ALL SIGN AGE SHALL BE REFLECTIVE PER ASTM DESIGNATION 04956 AND SHALL USE TYPE IV PRISMATIC REFLECTIVE SHEETING (HIGH INTENSITY PRISMATIC OR EQUAL) UNLESS OTHERWISE SPECIFIED. R1-1 "STOP", R1-2 "YIELD", R2-1 "SPEED LIMir AND STREET NAME SIGNS SHALL USE TYPE IX PRISMATIC CUBE-CORNER REFLECTIVE SHEETING (DIAMOND GRADE VIP OR EQUAL) 7. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENTS, All STREET STRIPING AND MARKINGS WITHIN A 500. PERIMETER OF THE CONSTRUCTION PROJECT WILL BE RESTORED TO A "LIKE NEW" CONDITION, IN A MANNER MEETING THE APPROVAL OF THE CITY INSPECTOR. 8. EXACT LOCATION OF STRIPING AND STOP LIMIT UNES SHALL BE APPROVED BY THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE PRIOR TO INSTALLATION. 9. CONTRACTOR SHALL REMOVE All CONFLICTING PAINTED UNES, MARKINGS AND PAVEMENT. All PAVEMENT LEGENDS SHALL BE THE LATEST VERSION OF THE CAL TRANS STENCILS. 10. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT LEGENDS SHALL BE THERMOPLASTIC UNLESS OTHERWISE SPECIFIED. PREFORMED THERMOPLASTIC ARROWS AND LEGENDS SHALL NOT BE ACCEPTABLE. -- ---® RIP RAP EN~c~,~~ .. ~!.:SIPATER DETAIL ~ 45- 40- 35- 30- "AS BUILT" A:COM DESIGN+ CONSUL T!NG SERVICES-AMERICAS 1 COLUMBIA PLACE 401 W. A STREET, SUITE 1200 SAN DIEGO, CA. 92101 TEL: 619.610.7600 www.aecom.com RCE ---EXP~ ---- REVIEWED BY: INSPECTOR EXIST GUARDRAil@ SECTION (CUT MIRAMESH WHERE ~ SURFSIDE LN Miramesh0GR GEOGRID NECESSARY TO CLEAR POSTS "" AND STAPLE SEAMS) "{0.{{§'' CARLSBAD BLVD ANCHOR TRENCH\ @TOE OF SLOPE ~EXIST EARTHEN SLOPEJ {SEE NOTES) DESIGN WIDTH {VARIES 181NCHES ~ 32 FEET) NOTES: MATERIALS: MIRAMESH ROLL SIZE= 8 FT WIDE x 150 FT LONG. INSTALLATION: ANCHOR TRENCH @TOP OF SLOPE {SEE NOTES) UNROLL MIRAMESH DOWN THE SLOPE FACE. INSTALL USING ANCHOR TRENCHES AT THE TOP AND BOTTOM OF SLOPE. AT TOP OF SLOPE, EXTEND MIRAMESH ONE FOOT (1FT) BEYOND TOP OF SLOPE AND INSERT INTO A MINIMUM 6 INCH WIDE x 12 INCH DEEP ANCHOR TRENCH, BACKFILLED WITH COMPACTED SOILS. AT BOTTOM OF SLOPE, EXTEND MIRAMESH INTO THE SAME SIZE ANCHOR TRENCH AT TOE OF SLOPE. OVERLAP MIRAMESH A MINIMUM OF 6 INCHES ALONG ROll EDGES. USE U -SHAPED SOIL STAPLES TO PIN MIRAMESH TO THE SLOPE FACE. INSTALL STAPLES ALONG THE ROLL OVERLAP AND IN THE ROLL CENTER. USE A MAXIMUM STAPLE SPACING OF 3.5 FT ON CENTER. SLOPE STABILIZA~I·~·~" SECTION ED SCALE: 11'+ -.1. -u PORTION OF EXIST AC PAVEMENT- TO BE REMOVED AND DISPOSED {LENGTH VARIES) 6'' CURB/ B" BERM 0 TRANSITION= 10' J~ 5 SEE PLAN w i= ~:;: EXIST 8" AC BERM tt: ~ TO BE REMOVED ~ §§ ~ AND DISPOSED "\..._ u I- EXIST GROUND QOW wo I="' ~~ ~o§ ::::i~a:: .... ~ .... ::..:z::!:!! uux , .... w :7;~2 CARLSBAD BLVD r EXIST AC PAVEMENT {THICKNESS UNKNOWN) VARIES ~ TYPE G CURB PER SDRSD SD~~f5~UTTER f "'\_EXIST CONCRETE PAVEMENT (THICKNESS UNKNOWN) NOTE: THIS DETAIL ALSO APPLIES TO NEW CURB INSTALLATION WITHOUT THE REMOVAL OF EXIST AC BERM. NEW CURB AND GU:r:-ER SECTION ED SCALE: 1tL = .1 -u CARLSBAD BLVD EXIST AC BERM TO BE EXIST ACSURFACE\ /PROTECTED IN PLACE @STREET GRADE 48_00± FS ~ TRENCH ~::X~~~~~~Ep~~OPE I u ~ ~ NOTE: WIDTH CAL/OSHA REQUIREMENTS EXIST 24" CMP TO BE REPLACED WITH 24" RCP 42.10 FL@ SECTION b:z~~fml~f--3/4" CRUSHED ROCK 4~ B"MIN 12"MAX SEE SAN DIEGO REGIONAL STANDARD DRAWING D-60 (PIPE BEDDING AND TRENCH BACKFILL FOR STORM DRAINS) FOR ADDITIONAL INFORMATION. STORM DRAIN TRENCH SECTIONED SCALE: 1/4 .. = .1·-u 1 -45 -40 -35 -30 LEGEND EXISTING FEATURES ~ WM --WATER METER 001 --FIRE HYDRANT 0wv --WATER VALVE !>CXl --BLOWOFF so ~ BACK FLOW PREVENTER q,, POWER POLE +---a STREET UGHT Ell PULLBOX lEI --ELECTRIC CONTROL PANEL [1'] TELEPHONE RISER ® --GAS VALVE GV lib MAILBOX 0 --SEWER MANHOLE 0 SEWER CLEAN OUT sco @) --STORM DRAIN MANHOLE -X----FENCE ---WALL * --PALM {SIZE AS NOTED) _a_ SIGN ~ SURVEY MONUMENT ED---SECTION/PROFILE DESCRIPTOR ---SHEET WHERE DETAIL APPEARS ABBREVIATIONS APPROX APPROXIMATE BC BEGINNING OF CURVATURE CL CENTERLINE CONC CONCRETE CP CONCRETE PIPE DWG DRAWING E fASTING EC END OF CURVATURE ELEV ELEVATION E'LY EASTERLY EXIST EXISTING FL FLOWLINE FM FORCE MAIN HOPE HIGH DENSITY POLYETHYLENE HP HIGH PRESSURE HT HEIGHT INT INTERSECTION LF LINEAR FEET LT LEFT MAX MAXIMUM MH MANHOLE MOD MODIFIED N NORTHING PCC PORTLAND CEMENT CONCRETE POT POINT ON TANGENT PRC POINT OF REVERSING CURVATURE PVC POLYVINYL CHLORIDE RC RELATIVE COMPACTION RCP REINFORCED CONCRETE PIPE R/W RIGHT OF WAY RT RIGHT SDCO STORM DRAIN CLEANOUT SDMH STORM DRAIN MANHOLE SDRSD SAN DIEGO REGIONAL STANDARD DRAWING STD STANDARD STL STEEL SWR SEWER TYP TYPICAL UNK UNKNOWN VCP VITRIFIED CLAY PIPE W'LY WESTERLY WTR WATER 1----~--1---------------------+-~~-~-----+--4~ CITY OF CARLSBAD ISHEE~I L____1__j ENGINEERING DEPARTh.4ENT 4 DATE DATE DATE 1 INmAL ENGINEER Of WORK REVISION DESCRIPllON DATE IMPROVEMENT PlANS FOR: CMP REPLACEMENT PROGRAM (CARLSBAD BLVD) NOTES, ABBREVIATIONS, LEGEND & DETAILS APPROVED: lBO PUBUC WORKS DIRECTOR, PE EXP._j_j_20_ ~ 20 10 @ ENVIRONMENTALLY SENSITIVE AREA 20 40 SCALE IN FEET ® --~~~~ow. ca~ ........ _ CALL 811 ATLEASTTWODAYS BEfORE YOU DIG UNDHGROUNDSERVICEALERTOFSOLiTHERII-CALI'ORNIA -- => w.-~rn ~ ~~60 z encooo <rm 00 coo:::VJO coDa N=>o<i "' ~ :::> "' Cl z <t APPRDX LIMITS OF SLOPE STABILIZATION COVERAGE AREA=: 4275 FT2 ± --~ 5+00 0+00 CONSTRUCTION NOTES: 1. PIPE BEDDING AND TRENCH BACKFILL PER SDRSD D-60. 2. REPlACE EXIST BASE COURSE SECTION WITH 4" CONCRETE OVER 6" AB ACROSS CARLSBAD BLVD. 3. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OF ALL SIGNING AND STRIPING DAMAGED OR REMOVED DURING CONSTRUCTION. 5. CONTRACfOR SHALL PROTECf ALL EXISTING UTILITIES IN PLACE UNLESS NOTED ON PLANS. 1+00 ~ I"'~ C:::l.ci,...,j_ .-;UVl II ;.,on 0 1.0 • coo>-~~~5~~(3g ~~~~ ~Sffi~ coZUJ!::.. r-!UC...X ~--~ ~~ .. i • • ~••u••w • ~ ' ==:l, 0?(4 J ~ 6. CONTRACTOR SHALL DEWATER UTILITY TRENCHES AS REQUIRED. 7. CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN TO THE CITY ENGINEER FOR APPROVAL BEFORE COMMENCING WORK. 8. RIGHT-OF-WAY (R/W) SHOWN ON PLANS IS SCHEMATIC ONLY. 9. INSTALL BIOCLEAN CURB INLET FILTER (OR APPROVED EQUAl). DEMOLITION NOTES: & PROTECT EXIST SIGN IN PLACE . .&. REMOVE AND REPLACE EXIST SIGN IN KIND, AFTER CONSTRUCTION. & REMOVE AND DISPOSE 260 SQ. FT± OF EXIST ASPHATIC CONCRETE § ~EXIST 8" AC BERM "' ~ ~o <i~~ 3 ~3\ ~~BS ~~~~ ~oZo o O.:rO ol"'z ~~~ ~~ffi~ffi .--tUc...c::c... :;: oi " N o0'10 u9~ OClq VlO II <t~>-:;\1~~0 ~;:::~~ +...JwU ..... uc...x STORM DRAIN ALIGNMENT TABLE NO. BEARING/DELTA RADIUS LENGTH REMARKS 1 N 44"54'41" W 41.40' 24" RCP (D-2DDD)' 2 N 70"59'15" E 8.85' 18" RCP (D-2DDD)' 3 N 18"28'42" W 149.25' 24" RCP (D-2DDD)' 4 N 48"44'54" W 110.54' 24" RCP (D-2DDD)' 5 N 18"09'52" W 90.04' 24" RCP ID-2DOO)' INDICATES WATER TIGHT JOINTS CARLSBAD "' ~ :::> "' "' '" "' :::> u r-2 ~ I I I ~EARTHEN SLOPE WITH ICE PLANT ~ I "' "' ~ ~ :::> :::> <.:> <.:> "' "' '" '" "' "' :::> :::> u u r-r-0 2 ~ A: COM DESIGN+ CONSULTING SERVICES-AMERICAS 1 COLUMBIA PLACE 401 W. A STREET, SUITE 1200 SAN DIEGO, CA. 92101 TEL: 619.610.7600 www.aecom.com I , I "' ~ :::> <.:> "' '" "' :::> u r-2 27.D7' 1,36.24' I I I lz "' Vi ~:;: ;il 0: =>"' "' u "' "' <.:>:3 ~ ~~ ~ ~ oou U<t ~:c :::> ~~ :::> :::> ""' "' "' "' Ut-"<tN "' ~~ "' "' 1.!:)!:!:!0"!~ '"-'" '" ><"'~ "'~ ,_r-"' "'~ )5:'wNr--0 :::>N §8 :::> :::>N ~G~~~ u<i u u~ r-"' r-r-"' ~~~~8 ou d!B. 0 ou ~r-~ ~r-w~Z..ul- "AS BUILT" RCE ___ EXP-----DATE REVIEWED BY: INSPECTOR DATE z Vi ;il 0: u ~~ U<t ~~ >-o ~s X ' wU ~~ ue BLVD EXIST 6" AC BERM CURB ALIGNMENT TABLE 0 0 + Lf') L.U z :::J :c u I-<( ~ NO. I BEARING/DELTA I RADIUS I LENGTH I REMARKS N 19'11'3D" W I I 4D.OD' I1YPE G CURB & GUTIER N 17"33'1D" W I I 2DO.SD' I1YPE G CURB & GUTIER ** 10' TRANSITION FROM 6" CONCCURB AND GUTTER TO 8" AC CURB PAVEMENT (THICKNESS UNKNOWN). MINOR GRADING WILL BE REQUIRED TO FILL ALL VOID REGIONS CREATED FROM THE AC REMOVAL THIS AREA DOES NOT INCLUDE THE AC REMOVAL NECESSARY FOR CURB & GUTTER INSTALLATION. .&. REMOVE AND DISPOSE 40 LF± OF EXIST 8" AC BERM. & REMOVE AND DISPOSE REMNANTS OF EXIST CONCRETE HEADWALL (35C-14) AS NECESSARY FOR CONSTRUCTION. & REMOVE AND DISPOSE EXIST TYPE F CATCH BASIN (35C-13). & REMOVE AND REPLACE 45 LF± OF EXIST 6" AC BERM AND 45 SQ. FT± OF EXIST AC SPILLWAY AFTER CONSTRUCTION. &. PROTECT EXIST 6" AC BERM IN PLACE. &. REMOVE AND DISPOSE 391.23 LF OF 24" CMP STORM DRAIN (TOTAL THIS SHEET). D D m ~ INDICATES LIMITS OF EXIST ASPHALTIC CONCRETE PAVEMENT. INDICATES LIMITS OF EXIST CONCRETE PAVEMENT. INDICATES APPROX LIMITS OF EXIST AC PAVEMENT TO BE REMOVED. )SEE DEMOLITION NOTE 3) INDICATES APPROX AREA OF EXIST SLOPE STABILIZATION. 1---~--1--------------------+-~~~--+--4~ CITY OF CARLSBAD ISHEE~, L___i_j ENGINEERING DEPARTMENT 4 DATE I INITIAl ENGINEER OF" WORK REVISION DESCRIPTION DATE INITIAL I IMPROVEMENT PLANS FOR: CMP REPlACEMENT PROGRAM (CARLSBAD BLVD) STORM DRAIN PLAN & PROFILE 20 10 1® __ ....., 20 SCALE IN FEET CALL 811 AT LEAST TWO DAYS BEFORE YOU DIG ca~ ..... ,. .... UNDE,GROUNDSERYICEAilRTOfSOUTHERNCALIFORNIA 69 ("(') f-UJ UJ I (./') UJ UJ (./') I 0 0 + t.n UJ z _J I u f-<( ~ 40 R ~ 0 u oz 231~~ ;:!8~ +~o ~ur- r ~-----------:-----____ .. ~7 ~~~--."":'"00N'o•o•ow4, ;/ ~~~~----~. II 6+00 CARLSBAD STORM DRAIN ALIGNMENT TABLE l NO. I BEARING/DELTA I RADIUS I LENGTH REMARKS Nl N 18"09'52" w I I 272.40' 24" RCP (D-2000)' ]'2II N 77"38'44" E I I 27.80' 24" RCP (D-2000)' * INDICATES WATER TIGHT JOINTS 7+00 ~~6"ACCURB A:COM DESIGN+ CONSULTING SERVICES AMERICAS 1 COLUMBIA PLACE 401 W. A STREET, SUITE 1200 SAN DIEGO, CA. 92101 TEL: 619.610.7600 www.aecom.com "AS BUILT" RCE---EXP----- REVIEWED BY: INSPECTOR BLVD DATE DATE z v;z ri!i<i: I;;, ~~ <tO r~~; g8~ ·~~ cou::!. CONSTRUCTION NOTES: 1. PIPE BEDDING AND TRENCH BACKFILL PER SDRSD D-60. 2. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPlACEMENT OF ALL SIGNING AND STRIPING DAMAGED OR REMOVED DURING CONSTRUCTION. 4. CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES IN PLACE UNLESS NOTED ON PlANS. 5. CONTRACTOR SHALL DEWATER UTILITY TRENCHES AS REQUIRED. 6. CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PlAN TO THE CITY ENGINEER FOR APPROVAL BEFORE COMMENCING WORK. 7. RIGHT-OF-WAY (R/W) SHOWN ON PLANS IS SCHEMATIC ONLY. DEMOLITION NOTES: &. PROTECT EXIST 18" RCP IN PLACE. & PROTECT EXIST 6" AC B~RM IN PLACE. & REMOVE AND DISPOSE 300.20 LF OF 24" CMP STORM DRAIN (TOTAL THIS SHEET). D INDICATES LIMITS OF EXIST ASPHALTIC CONCRETE PAVEMENT. 1----~--~------------------+-~r--r--+--1~ CITY OF CARLSBAD ISHEE~, ~ ENGINEERING DEPARTMENT 4 DAlE I INITIAl ENGINEER CF WORK REVISION DESCRIP110N DATE I INillAL OTHER APPROVAL DATE I 1NJT1Al OTY APPROVAL IMPROVEMENT PLANS FOR: CMP REPLACEMENT PROGRAM (CARLSBAD BLVD) STORM DRAIN PLAN & PROFILE APPROVED: TBD