Loading...
HomeMy WebLinkAboutEIR 87-02; CANNON ROAD; Planning Commission\~1\:.~ 10~ c\:.~ / PUMP ,/ STATION ,/ // ~/ 1>'7 % ~ /v?-7 / r /" / ,/ ,/ ~/ -0'" ...... --------, --Lr.Q!!!Ri!"-__ - --ATiGiiiME!![_------------ CANNON ROAD REACH 1 PCD/GPC 89-2 "600' Radius .~ \, ,> '\"""7'/) , . I t ." City of Carlsbadt .~k.l\ EIR 87-2tJ ). 7" 'i... ~ '7 2 ("} '7 ~ '7 'C"' ...... ..z... '7' '. '" o LEG.END ® PUMP STATION SITE '" 67 468 hs 924,1934-35) \. * 1 I GN' \: . I! I . , II1N J ...Q."..!~' \! i 14-3 MILSl i . 249 MILS I. " i: ~ ~ \. \ ~ , .' " \ ENCINITAS 6 MI. , SAN DIEGO 32 MI. 6 -, SCALE 1:24000 1 } 0 1 MILE ~--1 t=:==3 E'"""+3 ~--=3 t ==::::::::::f 1000 0 1000 2000 3000 4000 5000 6000 7000 [fEEl [-:1 H H E ~: -~=---;=3 I 1 :. 0 1 KILOMET Efl ~~----=::E3 Foe ~----~ CONTOUR INTERVAL 20 FEET DOTTED LINES REPRESENT lO·FOO1 CONTOURS NATIONAL GEODETIC VERTICAL DATUi'l OF 19/.9 D .PTH CURVES AND S,)L NDINGS !N FErT--DATUM IS t-1EAN L 'WER LOW WAT<:R S"L)t?f'.If\.F !:.HO'AN flEPRE'SfNTS T":..;:': ~ "PRO.(!!'.1ATf tiNE ,);: i'-1E:\!: 1-1 ,l.l \o\-,\iEf\ '74 • ~i~;l'r!~~~;~~;~{,:",. ' .. "'il ~-, Qq.:;: ,I <:: .M· ... ~ ~ '",- \"'UF"'-~ ~.",,-.. -, INTERIOR-GEOLOGIFAL SURVey. RESTON. Vlffc",NIA-1978 475 ;. ENCINITAS 8 MI. 476000m-E. Heavy·duty ~1edium·duty ROAD CLASSIFICATION Interstate Roule Light·duiy Unimproved d:rt Sbie Route --:-J 1 il S L: • ,;' 3670 10' 3667CJO.Om·N. ~ . .., C!) o u Cl: <:: =< <: " C!) 33°07'30" 117" 15' ~ ";l'--t-Cl "<"",'$-o "'0 <S' ~-v...z.. <S'~::;,.-<' o " .. 0\' ,., 'Y 't ~ ,....... --" ,~ .. " ~ r- COMPARISON O~~TERNATIVE PUMP STATION SITES: Cannon Roa,d. Sewage Pump Station Site Characteristic Site No. 1 1. Location Relative to Macario Park. at northerly end of park 2. Location Relative to Aqua Hedionda Lagoon. 1700' 3. Location Relative to future homes (H) or businesses(B} not near H or B 4. Is site acreage adequate for pump station con-YES struction without extensive grading? 5. Does site require an easement or property YES acquisition by the City? 6. Site Elevation. 15'-20' 7. Approximate pump station depth. 25' 8. Does the site contain riparian or salt marsh habitat? NO 9. Is the site adjacent to riparian or salt marsh habitat? YES 10. Approximate length of sewage force main (feet). 4600' Site No. 2 within park 2800' not near H or B YES NO 25'-30' 35' NO NO 5900' Site No. 3 not in park 2700' adjacent to H YES NO 10'-15' 20' YES YES 7500' Site No. 4 at northerly end of park 2100' adjacent to B NO NO 20'-25' 3~' NO YES 5500' Site No. 5 at northerly end of park 2300' not near H or B NO NO 20'-25' 30' NO YES 5500' "'C Q) (/) ·0 0.. e 'a. :' .... :.-.. ...... ....... •• _.__ c. ~ '. .' .... ::." a: UJ ~ < ~ III :::l :c II: /1) .... 0 UJ II: < II) u.. a: w ... II: <!I III < :::l A. < a: < II) 0 :c .... '" 0 < ~ ==:c 0 '" 00 w X < .... 11: ~ 0 d< 0 ==:::!: ~~ri~~j :c II) II: :c < en :::!: II: < :c :::!: !2 :.: ~ 0 .... < < (/) II: 0 III Z ..J ..J < < < ..J ~ ~ II) '" 0) CD < .< < 0 0 a: 0 0 <!I i~IILQ~ ~I 0 UJ CD a: :::l ~ !!'? 0 I a. ~ ~ Z o ..... ~ ..... W o W > HABITAT IMPACT SUMMARY CANNON ROAD DECEMBER 9, 1988 I MPACT S* (Permanent/Short-Term) Chaparral 1.7/1.4 Coastal Sage Scrub 1.5/0.9 Willow Woodland/Marsh** 1.9/0 MITIGATION (slope/created) 1.7/1.4 1.5/0.9 0/5.7 *RECON. 1933. Draft EIR for Reach 1 of cannon Road in the City of Carlsbad. ** 1 acre riparian woodland filloo, 0.8 acre riparian woodland shaded, 0.1 brackish marsh shaded ( , , , . ..~ .~ .. -:. " DEC 07 '88 10: 00 f'jBS/LOWR~' P o:;, . '- PUMP SITE. NO.1 PRO 1. It is at the northerly end of Macario Park (instead of being wi thin the park) and is secluded from planned homes. 2. The ground surface elevation at this site is between 15 feet to 20 feet which will provide a IIgood" pump station depth. 3. The site marsh, or 4. This site 5. The site station. CON does not contain any riparian habitat, salt similar environmentally sensitive features. minimizes the sewage force main length. is large enough to accommodate the planned pump 1. This site requires an easement from SDG&E. 2. The access road to the pump station site is quite long if access will be via the force main alignment. 3. It is closer to the lagoon than any of the other sites. PUMP STATION SITE NO.2 PRO 1. It is further from the lagoon that Pump Station Site No. 1. 2. It provides a larger area for pump station construction than does Pump Station Site No.1. 3. 4. 5 • The site does not contain any riparian habitat, salt marsh, or similar environmentally sensitive features. This site requires a shorter sewage PM than does Pump Station No.3. It is within City property and does not therefore, require acquisition of any easements. DEC 7 '88 1 1 .~~ :~"""''''r-- . " :." '(:.' " • '" " ';. .~ , ,; ! [lEe: 07 '88 10: 01 ~mS/L0["JR,( P.3 CON 1. The site is approximately 10 feet higher in ground elevation that Pump Station Site No. 1 and 15 feet higher than Pump Station Site No.3. The pump station will therefore need to be deeper than for Pump Station Sites No.1 or No.3. 2. It is located within the future Macario Park. 3. I t requires a longer force main length than for Pump Station Site No.1 • PUMP STATION SITE NO.3 PRO 1. 2. It is further from the lagoon than Pump Station Site No. 1. It provides a larger area for pump station construction than either Pump Station Site No.1 or No.2. 3. It has a ground elevation of approximately 10.0 feet, which minimizes pump station depth. 4 . 5. CON 1. 2. 3 • It's easterly location ml.nl.ml.zes the length of 30" gravity sewer that is required within Cannon Road. There will be easy access to the pump station site from Cannon Road. The site may contain low quality riparian habitat. It's easterly location maximizes the force main length. It will be adjacent to future homes and businesses. PUMP STATION SITES NO. 4 AND 5 PRO 1. The sewage force main length is shorter than for Pump Station Site No.3. 2. These sites are not adjacent to future homes. CON 1. The sites are within, or adjacent to, sensitive salt marsh or riparian habitat. DEC 7 '88 11:0': ! . i ': • I ~ I , i DEC 07 '88 10: 02 ~mS/LOj.,JRY P.4 2. Extensive grading may be required to create an adequate pad for the pump station site. 3. These sites are at the northerly end of Macario Park, but are closer to planned homes or businesses than Pump Station Site No.1. 4. These sites are close to the alignment of future Macario Bridge which may detract from effective site utilization and access. 5. They are adjacent or close to future businesses. DE C 7' 88 1 1 : [. 5 BBBBB8BB 61948~2868 PAGF.V14 -i I .