HomeMy WebLinkAboutRP 16-10; POKEWAN DELI; Planning CommissionCAL-GREEN NOTES
1-Entry doors and openings shall have non-absorbent floor and wall
finishes within two feet.
2-Adhesives sealant and caulking shall comply with The Regional air
pollution control or air quality management district rules or
SCD 1168 LIMITS as shown in tables 5.504.4.1 and 5.504.4.2 in
Division 5.5 of CaiGreen.
3-Aerosol adhesive in small containers less than 1 pound and not
more than 16 fluid ounces shall comply with statewide VOC
standards.
4-Documents to be provided at the request of the enforcing agency;
documents may include: a. Manufacturing product specification,
b. Field verification of on-site product containers.
5-lnstallation of HVAC, refrigeration, and fire supression equipment
shall comply with section 5.714.81.1 and 5.714.8.1.2.AII HVAC,
refregeration and fire suppression equipment to be installed
do not have CFCs.
CITY OF CARLSBAD
Administrative Permit
----------------------------------
Case No. fZP ib -/0
-\Lif'T ''{711 -·-6'-r--:-r-. ExibitNo. A -[l Date /[l'f!:i.OJ(
I
ALLEY
STORM WATER QUALITY NOTES
CONSTRUCTION BMP'S
This project "shall comply with all requirements of the Municipal
Permit issued by San Diego Regional Water Quality Control board
(SDRWQCB) and Municipal Storm Water National Pollution
Discharge Elimination System (NPDE5) Permit on January
24, 2007. (http://docs.sandiego.gov/munitode/MuniCode
Chapteri4/Chi4/Chi4Art02Division02.pdf St Storm Water
Manual http://www.sandiego.gov/devefopment-services/pdf/
news/stormwatermanual.pdf}
Notes below represent key minimum requirements for
construction BMP's.
1.The contractor shall he responsible for cleanup of ail silt &
mud on adjacent street(s), due to construction vehicles or
any other construction activity, at the end of each work day,
or after a storm event that causes a breech in installed
construction BMP's which may compromise Storm Water
duality within any street (s). A stabilized construction exit may
be required to prevent construction vehicles or equipment from
tracking mud or silt onto the street
2.AII stockpiles of soil Sa/or building materials that are intended
to be left for a period greater than 7 calendar days are to be
covered. All removable BMP devices shall be in place at the
end of each working day when 5 day rain probability forecast
exceeds 40%. *
3.A concrete washout shall be provided on all projects which
propose the construction of any concrete improvements which
are to be poured in place on site.
4.The contractor shall restore all erosion/sediment control devices
to working order after each run-off producing rainfal or after any
material breach in effectiveness.
5 All slopes that are created or disturbed by construction activity
must be protected against erosion and sediment transport at
all times.
6. The storage of all construction materials and equipment must
be protected against any potential release of pollutants into the
environment.
Updated 10/04/2014
FIRE NOTES
1-Locations and classifications of extinguishers shall be in accordance
with CFC 906 and California Code of Regulations (CCR), Title 19.
2-During construction, at least one extinguisher shall be provided on
each floor level at each stairway, in all storage and construction sheds,
in locations where flammable or combustible liquids are stored or used,
and where other special hazards are present per CFC Section 3315.1.
3-Buildings undergoing construction, alteration, or demolition shall
conform to CFC Chapter 33. Welding, cutting, and other hot work
shall be in conformance with CFC Chapter 35.
4-Address identification shall be provided for all new and existing buildings
in a location that is plainly visible and legible from the street or road
fronting the property. Where access is by way of a private road and the
building address cannot be viewed from the public way, an approved
sign or means shall be used to identify the structure. Premises
identification shall conform to CBC Section 501.2.
5-Wall, floor and ceiling finishes and materials shall not exceed the interior
finish classifications in CBC Table 803.9 and shall meet the flame
propagation performance criteria of the California Code of Regulations,
6-Title 19, Division 1. Decorative materials shall be properly treated by
a product or process approved by the State Fire Marshal with
appropriate documentation provided to the City of San Diego.
?-Dumpsters and trash containers exceeding 1.5 cubic yards shall not
be stored in buildings or placed within 5 feet of combustible walls,
openings or combustible roof eave lines unless protected by an
approved sprinkler system or located in a Type I or IIA structure
separated by 10 feet from other structures. Containers larger than 1
cubic yard shall be of non-or limited-combustible materials or similarly
protected or separated. CFC 304.3
8-Exits, exit signs, fire alarm panels, hose cabinets, fire extinguisher
locations, and standpipe connections shall not be concealed by
curtains, mirrors, or other decorative material.
9-0pen flames, lire, and burning on all premises is prohibited except
as specifically permitted by the City of CARLSBAD
10-The egress path shall remain free and clear of all obstructions at
all times. No storage is permitted in any egress paths.
----------------------1-------------CONC. SLAB FOR TRASH GARBAGE & GREASE
20' 30' f 20' ~ ~-~q.~k~b~~URFACES ~k~---------~~~----------------~~---------~ ARESMOOTH 1-.. -.. -1 .. -.. -.. -.. . . -.. . . _:>EALE~W~S~(:~IN_TE_D). _1_50.00:P_L_ .. _ .. _ .. -,----''-'I.J'c-
_® __ ~r __ ®1[1]1 1 ! .,8.5' ., 1
" ;
@l r:r! ~ ~I ~ w
@
-'I a. o· o.
~I
lCD
lv
lv
I
I +-,..L-·.-..
i -,---
EXIST. PARKING
@ ~ / ~~ I '-I -q-""'-18' , "'
' \_ ><<( I 1,. /
I
I I W>-I I ~~=-=-=-.:=-==-=~-,I
I I ( ' ~ ,1 I\ @@@@®@,1@1@ .;0 _, II '=======::::;~-:=:;:--=~=====' =:::::; 1 . 1 en !.\~ PARKING suRFACE ~ I' I, 1 r "---'---'~ ~ SLOPE 2% MAX. 3:: ,Q ~ ' \) IN BOTH DIRECTION I
I'--EXIST OFFICE / I I . '---"'--___./ I I
~:\'·Ws~D"""FL_oo_R~.-/' I --"-. ;f!~~ ~ w I 1
"\ I '-I ~ PA lNG su ACE ' Cl II I
@ I I ~~~----__.:\-1111----/ Co i N ~~~~% GnON I ~ul I' I
, -----I @?) / J ~~
----@-~,.4'~,. ---~ ~-----f---E-XIS-IING -I~ I ..c>._ . /I 'I'
___ ..:.. 'v~ STORAGE .o
1
-(-0-------a. 1 ,,
1
@I
I [yw] @ rl 1568 SF I§ 'I·~( '"' PARKING SURFACE ~ en . sLOPE2%MAX. ~ o I ~ 1\ ~ ' IN BOTH DIRECTION f ! )
EXISTING II /:/;;/;;/ ,1 ~ fi.J0L~~~~GE I ~.._;..c>~..-=.,·=-::=--==-==-:=--==-==::-:::::.. _ __.,[ H.C.VAN G
PARKING 1 ----EXIST ENLAR ED
I I v WALKWAY I SITE PLAN ~~] ® I / SLOPE2% MAX. NEW --------------L I~" v II EXISTING D GREASE TRAP N.T.S.
1-- --:::}) BUILDING I
EXIST.~ ~ ~j\~T~~RANT
WAU<JNAY L '--SLOPE 2% MAX. ~ rfFTH
PROPOSED
TENANT
IMPROVEMENT
(HATCH AREA)
EXIST. PARKING
EXIST. I'-4, WALitQNAY
SLOPE 2% MAX. ;J/l;'+-J£ ;~:.__-
'
TRAVEL
SlOPE 2% MAX.
:--. ,l __ 150:£2:...P~ . ....1....---_,.------'·. - .
'\ __ -~~TH J
I"-.
EXIST. DRIVEWAY I ' TRAVEL
SLOPE 2% MAX.
--EXIST.--SIDEWALK
PATHJ OF-TRAVEL
SLOPE 2% MAX.
r.;:;r""-.;_ __ __....----1076 SF
PARKING TABULATION:
RAMP
HALL
AREA REST. RM
NEW. DELl 1076 SF -153 =
OFFICE & STORAGE 1692 SF -201 =
NET
923 SF/300
1491 SF/350
PARKING
REQUIRED
= 3
= 5
1 ' RESTAURANT: 2713 SF -745 = 1968 SF/125 = 16 ' ~~~~~~--+-------r-----,_---~
·----0 -
'
8~{0E~1~8 1~1TCHEN 1302 SF -62 = 1240 SF/300 = 5
TOTAL SPACES REQUIRED = 29
TOTAL SPACES PROVIDED = 33
MADISON ST. SITE PLAN
1'-0"=14'
---------------------------------
GRAND AVE
CARLSBAD VILLAGE DR. e
SHT
1-SITE PLAN, DATA, SHEET SCHEDULE
2-FLOOR PLAN
3-CEILING PLAN
4-EQIPMENTS, FINISH SCHEDULE
5-EQUIPMENT DETAILS
D1 DETAILS
D2 DETAILS
P1 PLUMBING
P2 PLUMBING
M1 MECH
M2 MECH
E1 ELECTRICAL
E2 ElECTRICAl
E3 ELECTRICAL
S1 FOUNDATION, FRAMING
GENERAL NOTES:
1 THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES:
THE 2013 CALIFORNIA BUILDING CODE
THE 2013 CALIFORNIA ELECTRICAL CODE
THE 2013 CALIFORNIA MECHANICAL CODE
THE 2013 CALIFORNIA PLUMBING CODE
THE 2013 CALIFORNIA BUILDING ENERGY EFFICEINCY STANDARDS
THE 2013 CALIFORNIA FIRE CODE
THE 2013 CALIFORNIA GREEN BUILDING CODE
2 PROJECT SHALL COMPLY W/ CALIFORNIA FIRE CODE
4 ALL EXITS ARE TO BE OPENABLE FROM INSIDE WITHOUT THE USE OF A
KEY OR SPECIAL KNOWLEDGE
2 NO HAZARDOUS MATERIAL WILL BE STORED IN BUILDING EXCEED
2013 CBC
3 PROVIDE LEVER-TYPE HARDWARE FOR ALL DOORS
4 INTERIOR FINISH SHALL COMPLY WITH: 2013 CBC.
5 ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN AFLAME-
RETARDANT CONDITION
6 BUILDING OCCUPANT SHALL SECURE PERMITS REQUIRED BY THE
FIRE DEPARTMENT FROM THE FIRE PREVENTION BUREAU PRIOR TO
OCCUPYING THIS BUILDING
7 THE CONSTRUCTION, REMODEL, OR DEMOLITION OF A BUILDING SHALL
COMPLY WITH C.F.C. ARTICLE 87
8 THERE WILL BE NO CHANGE TO THE BUILDING SHELL, HVAC OR LIGHTING.
9 FLOOR AND WALL FINISH IN TOILET ROOMS ARE SURFACED W/ A SMOOTH
HARD NON-ABSORBENT MATERIAL EXTENDING FIVE INCHES UP THE WALL
SIMILAR SURFACING SHALL BE PROVIDED ON THE WALLS FROM THE FLOOR
TO THE HEIGHT OF 4 FEET AROUND URINALS AND WITHIN WATER CLOSET
COMPARTMENTS. 2013 CBC
10 SUSPENDED CEILINGS SHALL COMPLYW/CBC 2013
AN ADDITIONAL SIGN OR ADDITIONAL LANGUAGE BELOW THE SYMBOL
OF ACCESSIBILITY SHALL STATE "MINIMUM FINE $250" IS REQUIRED ON
PARKING SIGNAGE AT ACCESSIBLE PARKING
·:·-· /~,. "·"""
<> ,. -·
AN ADDITIONAL SIGN OR ADDITIONAL LANGUAGE BELOW THE SYMBOL
OF ACCESSIBILITY SHALL STATE "MINIMUM FINE $250" IS REQUIRED ON
PARKING SIGNAGE AT ACCESSIBLE PARKING (CBC 1129B.4)
PROJECT#: RP 16-10
APN: 203-303-24
LEGAL DISCRIPTION:
LOT 7,8,9, 10,11,12 OFT OWN OF CARLSBAD
AMENDED BLKS 38,39,49 & POR BLKS 33,37,&50
MAP 775
IN THE CI1Y OF CARLSBAD, COUNTY OF SAN DIEGO,
STATE OF CALIFORNIA
ADDRESS:
POKEWAN DELl
2958 MADISON ST, #101
CARLSBAD, CA 92008
OWNER
YOUNG SOO 1YO
2958 MADISON ST, #101
CARLSBAD, CA 92008
PHONE: (858) 776-0129
LOT AREA N/A (EXISTING)
ZONING COMMERCIAL
OCCUPANCY GROUP: B
DESCRIPTION OF USE: DELl
PREVIOUS USE: B/M
SPRINKLER NO
1YPE OF CONSTRUCTION: VB
FLOOR AREA 1076 SF
OCC.LOAD FACTOR
OCC.
LOAD
SITTING AREA 1
KITCHEN/SERVICE AREA
RESTRM AREAICIR.
363 SF 15
552SF 200
161 SF 100
TENANT IMPROVEMENT AREA: 1076 SF
24.2
2.8
1.6
NO MODIFICATION TO THE STRUCTURAL SYSTEM OF
THE EXISTING BUILDING WILL MADE WITH THIS PERMIT
SCOPE OF WORKS
A-INSTALL KITCHEN EQUIPMENTS TO MEET SAN DIEGO
COUNTY HEALTH DEPARTMENT REQUIREMENTS
B-NEW INTERIOR PARTITIONS, ELECTRICAL
& PLUMBING
1. ADD THE FOLLOWING NOTES ON THE SITE PLANS. IF APPLICABLE:
"I AM THE DESIGNER/OWNER IN RESPONSIBLE CHARGE OF THIS TENANT IM·
PROVEMENT PROJECT; I HAVE INSPECTED THE SITE/PREMISES AND
DETERMINED THAT EXISTING CCNDITIONS ARE IN FULL COMPLIANCE WITH CUR-
RENT SITE ACCESSIBILITY REQUIREMENTS TO THE EXTENT REQUIRED BY LAW. SIGNATURE:. _____________________________ --c, DATE: ___________________________________ ...
""I AM THE DESIGNER/OWNER IN RESPONSIBLE CHARGE OF THIS TEN-
ANT IMPROVEMENT PROJECT; I HAVE INSPECTED THE PREMISES AND
DETERMINED THAT EXISTING RESTROOM(S) SERVING AREA(S) OF AL·
TERATION ARE ACCESSIBLE ACCORDING TO CURRENT REQUIREMENTS. SIGNATURE:. _____________________________ ---;-DATE: __________________________________ •
2. ADD THE FOLLOWING NOTE ON PLANS. IF APPLICABLE:
"IF THE BUILDING INSPECTOR DETERMINES NONCOMPLIANCE WITH
ANY CURRENT ACCESSIBILITY PROVISIONS OF THE LAW. HE/SHE SHALL
REQUIRE SUBMITTAL OF COMPLETE AND DETAILED PLANS TO THE PLAN REVIEW DIVISION OF THE DEVELOPMENT SERVICES DEPARTMENT
FOR FURTHER REVIEW. PLANS MUST CLEARLY SHOW ALL EXISTJNG NON·
COMPLYING CONDITIONS AFFECTED BY THE REMODEL (INCLUDING SITE PLAN, FLOOR PLANS, DETAILS, ETC.) AND PROPOSED MODIFICATIONS
OF DEFICIENCIES TO MEET CURRENT ACCESSIBILITY PROVISIONS. THE
PLANS MUST BE STAMPED BY THE FIELD INSPECTOR PRIOR TO SUB-
MITTAL FOR PLAN REVIEW.""
STORM WATER QUALITY NOTES
CONSTRUCTION BMP'S
THIS PROJECT SHALL COMPLY WITH ALL REQUIREMENTS OF THE STATE PERMIT;
CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD. SAN DIEGO REGION.
ORDER NO. 2001-01, NPDES NO, CAS0108758.
(AVAILABLE AT; http"J/www.swrcb.ca.gov/rwqcb9/programs/sd_stormwater.html)
NOTES 1-<l BELOW REPRESENT KEY MINIMUM REQUIREMENTS FOR
CONSTRUCTION BMP'S.
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP OF ALL SILT AND
MUD ON ADJACENT STREET(S), DUE TO CONSTRUCTION VEHICLES OR ANY
OTHER CONSTRUCTION ACTIVITY. AT THE END OF EACH WORK DAY, OR AFTER A
STORM EVENT THAT CAUSES A BREECH IN INSTALLED CONSTRUCTION BMP'S
WHICH MAY COMPROMISE STORM WATER QUALITY WITHIN ANY STREET(S). A
STABILIZED CONSTRUCTION EXIT MAY BE REQUIRED TO PREVENT
CONSTRUCTION VEHICLES OR EQUIPMENT FROM TRACKING MUD OR SILT ONTO
THE STREET.
2. ALL STOCKPILES OF SOIL AND/OR BUILDING MATERIALS THAT ARE INTENDED
TO BE LEFT FORA PERIOD GREATER THAN SEVEN CALENDER DAY'S ARE TO BE
COVERED. ALL REMOVABLE BMP DEVICES SHALL BE IN PLACE AT THE END OF
EACH WORKING DAY WHEN THE FIVE DAY RAIN PROBABILITY
FORECAST EXCEEDS 40%.
3. A CONCRETE WASHOUT SHALL BE PROVIDED ON ALL PROJECTS WHICH
PROPOSE THE CONSTRUCTION OF ANY CONCRETE IMPROVEMENTS WHICH ARE
TO BE POURED IN PLACE ON SITE.
4. THE CONTRACTOR SHALL RESTORE ALL EROSION/SEDIMENT CONTROL
DEVICES TO WORKING ORDER AFTER EACH RUN-OFF PRODUCTION RAINFALL OR
AFTER ANY MATERIAL BREACH IN EFFECTIVENESS.
5. ALL SLOPES THAT ARE CREATED OR DISTURBED BY CONSTRUCTION ACTIVITY
MUST BE PROTECTED AGAINST EROSION AND SEDIMENT TRANSPORT AT ALL
TIMES.
6. THE STORAGE OF ALL CONSTRUCTION MATERIALS AND EQUIPMENT MUST BE
PROTECTED AGAINST ANY POTENTIAL RELEASE OF POLLUTANTS INTO THE
ENVIRONMENT
REVISIONS
Date
Scale
Job
Sheet
l
Of Shee1s
"' .,
0 ...
"' [:;j
"' "' e w z 0 I a.
Environmental Health Notes
The following Environmental Health notes are to be placed on your plans to
assist in providing clear direction between those involved in the actual
construction of a food facility including contractors and Environmental Health
Specialists. These notes will encompass most food facilities but are not
meant to be comprehensive for all food facilities or situations:
1. A concrete slab is provided for trash, garbage, and grease container.
If walls enclose area, the interior wall surfaces will be smooth, sealed
and washable (e.g., plastered smooth and painted, etc.).
2. All food-related and utensil-related equipment shall meet or be equivalent
to sanitation standards established by an American National Standards
Institute (ANSI) accredited program.
3. All floor mounted equipment will be installed on minimum 6" sanitary legs,
castors, or completely sealed in position on a 4 " high curb with
continuously coved base. Countertop equipment will be on 4-inch
sanitary legs or sealed to the counter unless readily movable.
4. If soft drink, ice or other dispensers are self-service, or if refills are
provided they must be push button types, or lever types where the lever
contacts the container at least one inch below the rim.
5. Any openable windows vent openings or other similar openings must be
provided with tight fitting screens of minimum 16-mesh to the inch.
Windows to be fixed at food prep, utensil-washing, open food and utensil
storage areas.
6. All exterior doors open outward and are self-closing and tight fitting.
7. Bi-fold, French, accordion style and roll-up doors cannot open into the
food prep, utensil washing or unpackaged food service areas.
8. Toilet room and dressing room doors must be self-closing, light fitting.
9. Delivery doors to have air curtain fans thai span the width over the door.
The fan must activate via a microswitch providing a minimum velocity
of 1600 fpm measured 3 feet above the ground.
10. A minimum of 10 foot-candles of light measured 30" off floor is provided
in walk-in refrigerated storage and dry storage rooms and at least 20-foot
candles is provided where food is provided for consumer self-service,
where fresh produce or prepackaged foods are sold or offered for
consumption; inside equipment such as reach-in and under-counter
refrigerators; in areas used for handwashing, warewashing, equipment
and utensil storage, and in toilet rooms.
11. A minimum of 50 foot-candles of light measured 30" off floor is provided
when working wfih food or working with utensils or equipment such as
knives, slicers, grinders, or saws where employee safely is a factor
and in all areas during periods of cleaning.
12. Shattershields for all lights above food preparation, work, and storage
areas will be provided.
13. All warewashing sinks to have 3 compartments that are a minimum size
of at leasl18"x18"x12" deep (or 16"x20"x12" deep) with a minimum 18"
drainboard at each end. If against a wall, it must have an 8" integral
backsplash. However, it must be capable of accommodating the largest
utensil to be washed. A warewashing machine does not substitute for
the sink requirement.
14. Sinks to have spout(s) capable of reaching each compartment.
15. Food prep sink compartment(s) to be at least 18"x18"x12" deep (or 1
6"x20"x12" deep) with a minimum 18" drain board. Separate food prep
sinks to be provided for meats and produce.
16 The 3 or 4 compartment bar sink to be at least 12"x12"x1 0" deep
(or 10"x14"x10" deep) with a minimum 18" drainboard at each end.
17. A separate wet waste dump fixture shall be provided for disposal of
drink or waste ice or coffee waste.
18. Each handwashing sink must have permanently mounted single-service
soap and paper towel dispensers.
19. The hot water heater will be a commercial type capable of constantly
supplying hot water at a temperature of 120oF to all sinks. In sizing the
water healer, the peak hourly demand for all sinks, etc., are added
together to determine the minimum required recovery rate.
20. All lavatories or hand sinks will have a combination faucet or premixing
faucet capable of supplying water tempered to 1 00°F. Self-closing or
metered faucet to provide at least 15 seconds of water without
reactivation.
21. All plumbing, electrical and gas lines shall be concealed within the
building structure to as great an extent as possible. All exposed
conduits, plumbing, etc. shall be installed at least 6" off floor and
3/4" from walls using standoff brackets.
22. Conduits, plumbing or piping cannot be installed across any aisle
way, traffic area or door opening.
23. Multiple runs or clusters of conduit or pipelines shall be furred in or
encased in an approved sealed enclosure.
24. All liquid waste shall be drained by means of indirect waste pipes
into a floor sink. Floor sinks are to be installed flush with the finished
floor surface and have suitable easily removable safety cover grates.
25. Floor sink to be 50% exposed when no access is provided for cleaning
or be in line with the front face of elevated freestanding equipment.
26. Approved backflow prevention devices shall be properly installed
upstream of any potential hazard between the potable water supply
and a source of contamination. Hoses shall not be attached to a faucet
or hose bibb unless an approved backflow preventer is provided.
27. Water supply to carbonators shall be protected by an approved
reduced pressure principle backflow preventer. The relief valve
shall drain indirectly to sewer with a legal air gap.
28. For cleaning floor mats, the janitorial sink to be a minimum 24" by 36"
floor-mounted type. Mops shall be placed in a position that allows
them to air-dry without soiling walls, equipment, or supplies.
29. The janitorial sink faucet will have a threaded outer lip for hose
attachment and an approved backflow prevention device. No
chemical dispensing systems or shutoff valves to be attached to mop
sink faucet outlet (unless a "sidekick" plumbing device is installed).
30. No condensate or wastewater including HVAC will drain into the
janitorial sink.
31. Grease trap to be located outside the food service activity area,
flush with the finished floor when indoors. Local wastewater district or
building department to be contacted for grease removal requirements.
32. Floor drains shall be installed in floors that are water-flushed for
cleaning and in areas where pressure spray methods for cleaning
equipment are used, in restrooms, janitorial rooms, sculleries, and at
bars with warewashing. Floor surfaces in areas pursuant to this shall
be sloped 1 :50 lo the floor drains.
33. Adequate ventilation is to be provided to all toilet rooms, janitor
closets with mop sinks, and indoor trash rooms and in
dressing/change room(s).
34. The floor finish will have a smooth surface under all equipment and
walkways will have a light texture only.
35. The paint used on walls and ceilings of all kitchen, food preparation,
work, and storage areas will be a gloss or semi-gloss enamel. Finish
material shall be a light color in food prep areas for easy cleaning.
36. Prior to installation, samples of finishes to be submitted to
Environmental Health for approval as needed.
37. Cold storage rooms shall be provided with a section of shelving
installed to hold shallow cool down pans -not to exceed 4" in height.
Space between shelving to be at least 8" high.
38. Backup dry storage shelving shall be a minimum of 96 linear feet
(measured with tiers) or 25% of kitchen, food prep, and work areas,
whichever is greater. Shelving shall be at least 18 inches deep and
start a minimum six inches off the floor surface.
39. Shelving over wet areas (sinks, mop sinks etc.) and food prep
surfaces will be metal.
An All eo.~rnc n!:lnc nno.ninnc tn he nrnna~rlu cc!JIIcrl
---
• N • (o
l
7 ;: I® wO o:O o<: t;;S: ltll~ .J-1-Z Zlo xo: I ~~ I w~ 24' 5'-511 Ol>-@ L_j
;:
wO I® o::O o<: t;;s:
.J-1-z Zlo xc< wu.
~SHELVES
104
STORAGE
MISSO
SOUP
' ' 8 HORCHATA
MACH.
~<J. ,-I--: n
,.-----+-----'---~.1-----! ..'-'f; OPOFTABLE, 1.
SODA ~ ! --/; 2B"T034" :
E1J
~
i i I I i 36"WIDE, ·
I u u C' ,~, 30"WIDE '·-,----,--] I +27"HIGH u 19" DEEP I I KNEE SPACE
30~x48" I CLEAR I I~ II CONT.
102
SITTING 0REA _ _j n
: :[41] I 1/ 1:12 RAMP
I' SEE 6102
FLOOR PLAN
SCALE 1/4" = 1'-0"
LEGEND:
EXISTING WALL TO REMAIN
29'-5"
101
ENTRY
NEW DOOR
IN EXISTING
STOREFRONT
OPENING
[::: ......................... :::1 NEW WALL (3-5/8"-25 GA. METAL STUDS@ 24" OC) SEE DETAIL
(TYP. INTERIOR NON-BEARING PARTITION)
NOTES:
1 ALL EXITS ARE OPEN FROM INSIDE WITHOUT THE USE OF A KEY OR
SPECIAL KNOWLEDGE
PROVIDE A SIGN ON OR NEAR EXIT DOORS, READING "THIS DOOR
REMAIN UNLOCKED WHENEVER THE BUILDING IS OCCUPIED"
2 ALL DOORS (NEW OR EXISTING) WILL BE 32" CLEAR MIN.
PROVIDE LEVER-TYPE HARDWARE FOR ALL DOORS
U.O.N. PER FLOOR PLAN (PANIC HARDWARE)
---------------------
u
ln
' "'
0
~ _,
<0
0
~ -· Ol
(o
' (o
~
NOTES:
1 NO ALCOHOLIC BEVERAGE SERVICE.
2 N/A
3 EXIT DOORS TO BE OPENABLE FROM INSIDE WITHOUT
USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT
4 PLANS FOR ALL FIXED FIRE PROTECTION EQUIP. SUCH AS
STANDPIPES, SPRINKLER SYSTEMS & FIRE ARLARM SYSTEMS,
MUST BE SUBMITTED TO, AND APPROVED BY, THE FIRE
PREVENTION BUREAU BEFORE INSTALLATION
5 WATER HEATER/BOILER IS ON CALIFORNIA ENERGY COMMISSION LIST
6 CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL
POTABLE WATER SUPPLIED APPLIANCES AND EQUIPMENT
7 FAUCETS TO BE 2.2 G.P.M MAX
8 TURBIN UPDRAFT EXHAUST FANS SHALL BE HINGED
AND CHAINED FOR CLEANING VERTICAL DUCT
9 WET TYPE STEAM TABLES MUST BE PROVIDED WITH A FILL LINE!
FAUCET CAPABLE OF FILLING ALL COMPARTMENTS
10 WOKS MUST BE PROVIDED W/ A FILL LINE/FAUCET
11 MUL Tl SERVICE CONSUMER UTENSILS
12 WATER SUPPLY TO CARBONA TOR SHALL BE PROTECTED BY
APPROVED REDUCED PRESSURE PRINCIPLE BACKFLOW
PROTECTOR. THE RELIEF VALVE SHALL DRAIN INDIRECTLY
TO SEWER W/ A LEGAL AIR GAP
13 ALL CEILING TILES IN THE FOOD PREPARATION AREAS,
SERVICE AREAS, MOP RM AREAS, TOILET ROOMS, AND ABOVE
OPEN TOP BUFFET TABLES MUST BE SMOOTH, WASHABLE,
NON-ABSORBENT AND LIGHT IN COLOR
14 PROVIDE 5" CONTINUOUS BASE AT RESTROOM
15 ALL KITCHEN EQUIPMENTS (GAS & ELECTRIAL APPLIANCES)
MUST BE LISTED BY AN APPROVED LISTING AGENCY
16 IF SOFT DRINK & OTHER DISPENSERS ARE SELF SERVICE/REFILLS
THEY MUST BE PUSH BUTTON TYPE, OR LEVEL TYPE WHERE
THE LEVER CONTACTS THE CONTAINER AT LEAST ONE INCH
BELOW THE RIM.
17 STEAM TABLES WILL BE ELECTRIC 3 PHASE 208V OR GAS
18 PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED
WITHIN BLDG STRUCTURE TO A GREAT EXTENT AS POSSIBLE
1g ALL LINES ARE NOT CONCEALED TO BE SECURED 6" OFF FLOOR
AND 3/4" FROM WALL USE STANDOFF BRACKET
20 PROVIDE SEALED CONC. FLOOR W "SLIM FOOT" CERAMIC BASE
USE TWO-PART EPOXY
21 ALL CHEMICAL INJECTION SYSTEMS TO BE INSTALLED
DOWNSTREAM OF A PROPERLY INSTALLED PRESSURE VACUUM
BREAKER OR AN AIR GAP. THE SYSTEM SHALL NOT BE DIRECTLY
OR INDIRECTLY CONNECTED TO THE MOP SINK FAUCET OUTLET .
22 THE PROPOSED PLASTIC FOAM INSULA TED COOLER AND FREEZER
BOXES WILL COMPLY W/ UBC SECTION 2602 FOR FOAM PLASTIC
INSULATION
23 SUSPENDED CEILINGS SHALL COMPLY W/ ASTM C 635 & ASTM C 636
24 NO FRUITS OR VEGETABLES WILL BE PREPPED ON SITE
25 VENTED DUAL CHECK VALVE OR ASSE 1012/1022 COMPLAINT
BACKFLOW DEVICE WILL BE INSTALLED BETWEEN THE ESPRESSO
MACHINE AND THE WATER SOURCE.
26 TOTAL NUMBER OF EMPLOYEES PER SHIFT INCLUDING
OWNERS & MANAGERS: THREE
LEGEND:
M FIRE EXTINGUISHER W 2-A-10B:C
/.A FIRE EXTINGUISHER W LIST CLASS "K''
DOOR SCHEDULE
®
®
EXISTING DOORS
3'-0"xT-011
NEW DOOR
3'-0"x7'-0" (CLEAR, UNOBSTRUCTED
OPENING WIDTH OF 32 INCHS MIN)
NOTES:
0)
®
®
CD
®
®
0
®
®
ALL EXTERIOR DOOR ARE SELF-CLOSING
FLOOR DRAIN
COUNTER
EXISTING STOREFRONT WINDOW
ALL WINDOWS ARE FIXED WINDOW
STUCCO TO MATCH EXIST. OVER 3/8" CDX
OVER EXIST. WINDOW FRAME
EXISTING ELEC. PANEL
LOW WALL +36"
LOW WALL +36"
PROVIDE GYP. BD. OVER 1 5/8" CHANNEL
@ 24" OC WALL FURRING
NEW COLUMN SEE SHEET S1
MECHANICAL NOTES:
1-PROVIDE ULTRA LOW FLUSH TOILETS, AND MAXIMUM
2.2 GMP FLOW ON FAUCETS.
2-PROVIDE EXPASION TANK OR OTHER APPROVAL METHOD
OF RELIEVING PRESSURE (SEC 608.3 CPC)
3-WATER HEATER/BOILER IS ON CALIFORNIA ENERGY
COMMISSION (CEC) LIST
4-AUTOMATIC TRAP PRIMING FOR FLOOR DRAIN
5-ALL EXHUAST FAN ARE MIN. 10' AWAY FROM ANY AIR
INTAKES, A.C. UNITS ETC ..
6-EXHAUST DUCTS SHALL BE EQUIPPED WITH BACK-DRAFT DAMPERS
~
(0 ... 0 ...
"' ,._
"' ro-"' ~ w z
0 J: a.
0 (!) w Ci
«~
REVISIONS
Date
Scale
Job
z
:5 c..
0::
0
0
_J
!.L
Sheet
2
Of Sheets
l.l.
" ~ 5 (/J
>-' w w 0:: tii
6 > z 0 ()
"' ~ ...