Loading...
HomeMy WebLinkAboutSDP 97-01; BELLA LAGO; Planning Commissioni• ////' 1 / 7- 7. bD - - L zv co owo 27.0' : IF -. .. - VVVVVVV I N -:':'" C) 4 46 co 0 -96 90, CO* Q0 ZO_VV V . •V '-. V "A V . 72, 2 V • 'V ' V 4't t 6' ly s 4 Al- Qo .1 1ÔN4(7 51.47 V . V / --12.Q4' OLL) LO 6(v 60.0 "V " 0 3.20 NNN Nz : N V 16.0 101 FF 60.7 VVVV V !2.o FF 59.0 City of Carlsbad Planning Department February 5, 1999 E. Dale Gleed Brookfield Homes 12865 Pointe Del Mar, Suite 200 Del Mar CA 92014 SUBJECT: PRE 99-05 - SUBSTANTIAL CONFORMANCE REVIEW FOR SDP 97-01 BELLA LAGO - AVIARA PLANNING AREA 28 APN: 215-790-01,-06,-1 1; 215-791-04,-05,-07,-12,-14 A preliminary review of your project was conducted on February 4, 1999. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. The preliminary review does not represent an in-depth analysis of your project. Additional issues of concern may be raised after your application is submitted and processed for a more specific and detailed review. Planning: 1. The submitted Substantial Conformance exhibit proposes unit changes on eight (8) lots within the Bella Lago development (SDP 97-01). The proposed revisions would involve changing seven (7) of the two-story models (Model 3 and 313) to one-story models (Models 1, 1 R, 2 and 213). In addition, the home on Lot 6 would switch from a Model 1 R to a Model 213, both one-story products. A table summarizing these changes, with specific lot references, is attached. The Bella Lago development is quite visible from Batiquitos Lagoon and the neighboring public thoroughfares. As a result, the Aviara Master Plan limits the number of two-story structures allowed in Bella Lago. Since the proposed revisions create more one-story units that originally approved, and since all required property line setbacks are still being met, the Planning Director has determined that the application qualifies for substantial conformance with the approved permit and therefore, approves the changes to the project based on Planning Director Administrative Policy No. 35. Please submit two (2) blueline copies (24" X 36") of all applicable exhibits for the project file and a reproducible 24" X 36" mylar copy of the amended site 2075 La Palmas Dr. • Carlsbad, CA 92009-1576 • (760) 438-1161 • FAX (760) 438-0894 PRE 99-05 - SUBSTANTIAL CONFORMANCE REVIEW FOR SDP 97-01 February 5, 1999 Page 2 plan. The mylar must be submitted, stamped "Substantial Conformance", and signed by the Planning Director prior to issuance of any building permits for those lots shown in this Substantial Conformance request. Engineering: 1. The proposed changes to product type and driveways must comply with City Standards, where a three (3) foot minimum distance from lot line to top of apron flare is required. Lots 2, 3, 5, 6, and 44 need correction. Conditions of approval of the Site Development Plan required correction of some of these lots. 2. Sidewalk underdrains (SDRS D-27) are also a potential issue. It appears that the plans show more that one underdrain per lot. Only one, if any, drain per lot is allowed. The typical detail on sheet one of the approved site plan shows surface flow across driveways to the street. The typical detail on sheet one is supported by staff as an ideal maintenance-free system. Please contact Michael Grim at (760) 438-1161, extension 4499 if you have any questions. Sincerely, cr GARY E.WAYNE Assistant Planning Director G EW: MG: mh C: Michael J. Holzmiller Dennis Turner Clyde Wickham Bobbie Hoder File Copy Data Entry Memorandum TO: Associate Planner, Mike Grimm FROM: Associate Engineer, Clyde Wickham DATE: February 2, 1999 RE: PRE 99 - 05, Bella Lago (P.A.28) proposed changes to SDP 97-01 We have completed our review of the preliminary design identified above. The proposed revision of plan types raises a few issues with driveways and storm drains. We also want to reiterate concerns about design and lot drainage. I have listed our concerns below. Please incorporate these comments in your letter to the applicant. The proposed changes to product type and driveways must comply with City Standards, where a 3' minimum distance from lot line to top of apron flare is required. Lot 6 & lot 5, lot 2 & lot 3, lot 44 the more we looked the more driveways we found needing correction. Conditions of approval require correction of some lots for this issue. 2. Sidewalk under drains (SDRS D-27) are also a potential issue. It appears that the plans show more than I underdrain per lot. Only 1 (if any) drain per lot is allowed. The typical detail on sheet 1 of the approved site plan shows surface flow across driveways to the street. The typical detail on sheet I is supported by staff as an ideal maintenance free system. Overall we can support the proposed changes but while we are changing things, we want to correct and improve these issues raised above. Please pass these comments on to the applicant. If you or the applicant have any questions please give me a call at ext. 4353. Associate Engineer Land Development Division