Loading...
HomeMy WebLinkAboutCDP 03-36; NASSAR RESIDENCE; Site Plan---------------.-------- 6enercil Notes Job c.crd req'd to be available for slgnatlK'e at Job site. Contractor to provide the bld'g division a completed CEC form CF-6R prior to the request for a final lnspec.tlon. It Is rnderstood that no final Inspection Hill be made until this form Is submitted All HlndoHs lnc.ludlng frenc.h t atrium doors to be dual pane rnless noted. No Hafer bd. to be used In place of shear panels noted. Bug sc.reens to be Installed prior to final. P. 4 T. relref valve to outside of building at Hater heater. In seismic zones B 4 4, Hater heaters sliall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points Hlthln the upper one- third (113) and loHer one-third (113) of Its vertlcle dimensions. At the loHer point, a min. distance of ( 4") shall be maintained above the controls Hlth the strapping. Shower and tub/shower combinations shall be provided with lndlvldlal control valves of the pressure balance or the thermostatic. mixing valve type. Changes from the approvea plans during construction other than I) Cabinet c.hooges when not being supported entirely ~ the roof structure, 2) Interior door ood fireplace reloc.atlon shown on the approved ploo, B) A single non-bearing Hall relocation when not creating an addltTonal room, ana 4) Interior nonsruc.tural Hall flnfshes; shall c.ause plan approval and c.onstruc.tlon to be suspended, a new plan c.hec.k (for a neH plan showfa changes) Hill be submitted for review and approval throu the normal plan c.hec.k process. Surface water o be drained away from building for at least 5 feet with a min, grade of 2% of the overall lot drainage slope must be maintained at 1% min, from rear to front with a min. slope of 1/2%. Slope all finish grades OHay from structure for a positive drainage @ 2% for a min. of 5'-0" toward approved drainage facilities. Provide a 0.5 percent min. slope for the entire site. Finish floor to be a min. of 6" above c.rown of street or per building dept. requirements. ______ (V'i,ere appllc.able)__ __ _ __ _ Hater/sewer c.onnec.tlons shall be Installed to c.lty stds. Water meter to be Installed H/box ood phone conduit per c.lty stds. Any work to be performed Hithln the ilty r!Qht-of-way will require an enc.roac.hment permit. The work fo be done Hlthln the right-of-way must be completed prior to rec.elvlng an ouupanc.y permit. Any existing Improvements that are damaged by the work, delivery of materials or other means, must Be repaired prior to oc.iupanc.y. Well lowtlon to be a min. of 150' from septic. system. Provide an all weather driveway per c.ornty std. (min. 10' wide) This building design meets the design requirements set fourth In section l40B(c.) Title 24, CCR TERRY ARMENTROUT Note, After Installing Insulation, the lnsvlatlon nstaller shall post In a c;onsplc;vovs loc;atlon '1 the, building a c;e,rtlf1"ate sgie,d l:y the ln!ltaller and too builder stat'1g thot the, lnstallat!on c;onforms 1-1lth the re,qvlreme,nts of Title 24, Part 2, C,hapter 2 5:1, and that materials Installed c;onform 1-1lth the, reqvlre,moots of Title, 24, Choptel" 2, 5vlx.hapter 4, Artlcle,s 3. The, c;e,rtlflc;ate, shall state the manvfac;tvrer's name, and mate,rlals lnstalle,d 'R" valve,, and ('1 oppllc;atlons of loose, till Insulation), the minimum lnstalle>d 1-11>I,:t\t pe,r squae, foot c;onslstent 1-1lth the, mQl\l/fac;ture,r's labeled de,nslty for tne, de>slre>d "R" value. Sec;tlon 140:l/d! ntle 24, CC.R. Note, Elvllder shall provide> the, original ocwpant Hlth o 11st of the, he>otlng, coollng, Hater heotlng and lighting 51JStems and c;onse,rvatfon or solar de,vic;e,s lnstolled In the bulldlng and lnstroc;tlons on hoi-1 to vse, l;he,m e,l'tfc;le,ntly. 5'!,c,, 140B(e,) Title 24, CC.R. Note, Any ve,rtfc;al wt or fill dlffe,r"'11:lal In e,xe,e,ss of 12' betl-le,e,n adjacoe>nt prope>rtles shall be svpporteci i:y an opprove>d re>talnlng wall. Hood re>talnlng Halls shall not be vse,d to re,taln more, than 24' of soil. The, c::rode> dlffere,ntlol beb-le,e,n adpe,nt properties may be relfe,ve,d l:y o slope no£ to exc.eed ti-lo horizontal to one, vertlc;al on the foi-1 property If opproved by the o><ner of said low prope,rty In a form of o re,c;orded e,ose,me,nt or wvooant running Hlth the, land as approve>d by the Glty Attorne,y. MMOl-1.02 Note, All bvlldlng Hater supply 51JStems In 1-1h1Gh quick-acting valves are lnStalle,d sholl be provlde>d 1-1lth devices to absorb high pre,s,;ure,s r"51Jltlng from the qufc;k c;foslng of the,se valves. These, pre,ssvre-obsorblng devices shall be either air Ghombe,rs or approve,d me,Ghan1"al devfc;e,s. Woter preS!lUre> sho.:;k orre,stors sholl be lnstalle,d as c;fose, as possl?le, to qulc;k-acotlng volves at the e,nd of long pipe or ne,ar batteries of flxtvre,s or both. e,pe, 601.10 Note, Provide> c;onsl:nJC,tfon site addre,ss, 'approved nvmbe,rs or address signs shall be provided for at c;onstrvc;tlon sites. lhetj shall be painted on the foc;e, of the, c;vrb on the, front side of the lot prior to lhe, first lnspe,c;tlon. Gurb rl!mbers shall be a minimum of three lnche>s (B") '1 height and have, wntrastlng or re,fle,c;tlng bac;kgrovnd and permanently pointed on the wrb foce,, Te,mporary stre,e,t narne,s shall be painted on the, c;urf,s of oil stre>ets at the stree,t lnterse,c;tlons. In the e,ve,nt that no c;vrb exists, temporary wnstrvc;tlon site adcre,ss slql6 and temporary stre>et name signs shall be posted at a he>lght of betHee>n 42>" and 12'. Su<;h te,mporary 51<]15 shall be weather re,sl5tant on approved material. All nvmbers and nane signs shall be maintained to the, satisfaction of the, Fire Masha! and Bvlldlng Off1"ial.' After Hlndows are, Installed, addre,ss nvmbers shall be pfac,e,d on o HlndoH fac;fng the str"8t and shall remain le,gble vntll pe,rmane,nt addre,5$ sign Is lnstafle,d, Note,, Lot shall be dralne,d from re,ar to front to oo approve,d drainage, system. lnstallatlon of obstrvctlons, I.e., bloc;k fe,nc;e,s, wood fe,nc;e,s, rocok5, landscaping, mound, e,tc;,, c;an not blocol< flow. Final grading of lot mvst tal:e place prior to reque,st for final lnsp«tlon. NOTE, RETAININe HALLS TI!AT ARE 2' IN HEIISHT MEASURED FROM THE BOTTOM OF THE FOOTINGS, POSTS, KEYS OR STRIJC71!RE TO THE TOP OF THE HALL AND THAT RETAINS 12" OR MORE OF SOIL, REGUIRES PERMITS AND INSPEC,TI0NS. SUBMIT ENelHEERED DE5IeN. SITE PLAN FOR COASTAL DEVELOPMENT PERMIT GARFIELD ST.-SINGLE FAMILY RESIDENCE 3217 GARFIELD STREET LEGAL DESCRIPTION TRACT NO. 201 OF THUM LANDS, IN THE CITY OF CARLSBAD, COUNTY SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO THE MAP THEREOF NO. 1681, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY ON DECEMBER 9, 1915. EXIST!Ne RETAININe WALL W WOOD FENCE OVER.-.__ / () -' g PATIO PROPOSED RESIDENCE ROUND COL. El 0 SITE DRAINAcSE \ '-0' __....-,-ROOF DECK AREA (25%) OF ROOF I I I I = I I 9 I ~ tr: ~I ~I "l I ll'l 2'-S"I + + IH' 11 + I + O:=:.t;:::E."5':.0...'.~_-_...,, _ J_ -----71 _J 140.00' () 1 ..----::t--EXISTINcS SIDEWALK ----------~ 9 ======I===========:::;===~ () PROPOSED APPROACH _, PER CITY STD. IQ GARFIELD ST. EXISTINe CURB 4 eUTTER ---EDeE OF PAVEMENT ---"I<--------------------- NOTE: EXISTINcS SUILDINcS TO BE REMOVED EXIST!Ne WATER 4 SEWER LATERAL TO SERV NEW SUILDINe. Site Data ENGINEERING 6Y, APN, Sill: ADD. , 204-125-002 5211 GARFIELD ST. RAFAEL D. DIVINA -P.E. (No. G050011) 515 HOr.Al<D RD., MADERA , C.A. '1'6'1 PH. (55'1) bi4-b5'1e> OC.c.tJPANCY : R-B (Dl-'lELLINe) U-1 (GARAeE) TYPE OF C.ON5TRIJC,TION , V-N GENERAL NOTES: EXISTING LAND USE: SINGLE RESIDENCE RH PROPOSED LAND USE: SINGLE RESIDENCE RH EXISTING ZONING: WATER, SEWERS, STREET, FIRE PROTECTION: GRADING SUMMARY: CUT FILL IMPORT LAND USE SUMMARY: SITE ACREAGE: PERCENT LANDSCAPE: BUILDING COVERAGE: % 25 R-3 & BOAZ CITY OF CARLSBAD 0 90 90 cu. 3520 SQ. FT. CU. YDS. YDS. FIRST FLR.: 1109 SQ. FT. CARPORT: 148 SQ. FT. PATIO: 294 SQ. FT. TOTAL BUILDING COVERAGE: 1551 SQ. FT. PARKING: UNDEVELOPED AREA: 0 DENSITY: 12.3 du/ ac BUILDING AREAS NOTE, (44%) 2 LIVIN& AREA, 24'l'l CARPORT AREA, l'l3 S.F. S.F. S.F. S.F. S.F. THIS PROJE:GT SHALL GOMPL Y WITH iHE: 2001 EDITION OF THE CALIFORNIA SUILDINcS CODE: (TITLE: :24) PORc.H AREA, II PATIO AREA, 2'l4 HHICH ADOPTS THE: l<!c:t7 USC, 2000 UMG, :2000 UPC AND iHE: IC!<!<! NEG. DECK AREA, 13<1 GRADING NOTES I. ALL cSRADINcS SHALL COMPLY WITH APPE:NDIX CHAPTER SS OF THE: '"'"'e, c.Bc.. 2. PROVIDE A COMFAC.TION REPORT A5 REQUIRED BY THE C.ITY 4 PREPARED 6Y AN APPROVED TI:STING A8ENC.Y. S. DURINe CONSTRUCTION OPERATIONS THE CONTRACTORS 5HALL UTILIZE APPROPRIATE ME:THODS TO C.ONTROL DUST. 4. NO DRAINA8E TO BE DIRECTED iO ADJACENT PROPERTY, PROVIDE A MIN. 2% SLOPE AHAY F'ROM THE 6UILDINe. S. EARTHY'IORK5 SHALL 6E IN ACCORDANCE HITH THE 501L INVE:STlcSATION REPORT DATED JULY 26, 2004, BY HU ASSOC. INC., ll"ISS RIVERA RD., SANTE F'E, CA. "10610-220"1, 552-6"16-6062. GENERAL NOTES NO 220-VOLT ELE:CTRICAL GIRCUT OR eAS OUTLET 5HALL BE LOCATED WITHIN THE: FIRST FLOOR 'Y'!ET6AR' AREA AND 5URROUNDINcS ROOMS. ' ' fl--··-,si;.-.. ._½/oS Sheet Index : 1 2 5 .. 5 6 7 & 9 "' D2 SITE PLAN FLOOR PLAN SHEARWALL PLAN FOUNDAllON ELEVATIONS ROOF FRAMING 5EC110N5 MECHANICAL ELECTRICAL GENERAL NOTES GENERAL NOTES. SITE PLAN DRAWN W1 T. ARMENTFWUT CHECKIO IY .... 6 / 2004 sc.w: I/e"=I' JOI NO. SAMINASSAR HU 1 0, <l SH<ffl