Loading...
HomeMy WebLinkAboutCDP 08-19; HOEHN SERVICE ADVISORS ADDITION; Site Plan! ABBREVIATIONS & AND FOM c·AcE OF MASONRY L ANGLE FOS FACE OF STUD @ AT FP FIRE PROOF * CENTER LINE FS FLOOR SINK DIAMETER FW FLAT WALL J_ PERPENDICULAR FT FOOT OR FEET t,) POUND or NUMBER FURR FURRING EXIS11NG FDN FOUNDATION FIN FINISH AB ANCHOR BOLT FIX FIXED ACOUS ACOUSTICAL FIXT FIXTURE AGGR AGGREGATE FLR FLOOR AL ALUMINUM FTG FOOTlNG APPROX APPROXIMATE ARCH ARCHllECTURAL GI GALVANIZED IRON ASPH ASPHALT GA GAUGE AC AIR CONDITIONING CALV GALVANIZED AD AREA DRAIN GL GLASS AT ASPHALT TILE GR GRADE ADJ ADJUSTABLE GYP GYPSUM BP BUILDING PAPER HVAC HEATING, VENTILATING BOF BOTTOM OF FOOTING AND AIR CONDITIONING BM BENCHMARK HORIZ HORIZONTAL BD BOARD HR HOUR BET BETWEEN HGT HEIGHT BLDG BUILDING HDCP'D HANDICAPPED BITUM BITUMINOUS HB HOSE BIBB BLK BLOCK HG HOLLOW CORE BLKG BLOCKING HM HOLLOW METAL BM BEAM HW HOT WATER BOT BOTTOM HDR HEADER HDWD HARDWOOD CL CENTER LINE HDWR HARDWARE CLG CE.,LING HTG HEATING CONG CONCRETE HTR HEATER CB CATCH BASIN Cl CAST IRON ID INSIDE DIAMETER CJ CONSTRUCTION JOINT IE INVERT ELEVATION co CLEAN OUT INSUL INSULATION cw COLD WATER INT INTERIOR CAB CABINET CEM CEMENT JAN JANITOR CER CERAMIC CERT CERAMIC TILE JST JOIST 'J C'FLASH COUNTER FLASH JT JOINT C. CHL CHAIN LJNK LAC LACQUER " CLR CLEAR LAM LAMINATE z CNTR COUNTER ii: COL COLUMN LAV LAVATORY LVR LOUVER D.. COND CONDITION LT LIGHT w CONST CONSTRUCTION ::, CONT CONTINUOS MO MASONRY OPENl1'4G -' CONT'R CONTRACTOR "' CDR CORNER MAX MAXIMUM a: MECH MECHANICAL "' CORR CORRIDOR MEMB MEMBRANE :; -CTSK COUNTERSINK MFR MANUFACTURER -' CTR CENTER MIN MINIMUM w MIR MIRROR 0 DA DOUBLE ACTING MISC MISCELLANEOUS :;· DBL DOUBLE MT MET AL THRESHOLD D.. DEPT DEPARTMENT MACH MACHINE r-DF DRINKING FOUNTAIN MAS MASONRY "1 DIA DIAMETER MATL MATERIAL "' DISP DISPENSER MTL METAL -owe DRAWING MH MANHOLE DF DOUGLAS FIR MOV MOVABLE "' DH DOUBLE HUNG 0 DS DOWNSPOUT NIC NOT IN CONTRACT 0 £,I DET DETAIL NTS NOT TO SCALE Q> DIAG DIAGONAL NDM NOMINAL "' DIM DIMENSION NAT NAlVRAL -ON DOWN NO. or # NUMBER i DD DITTO (REPEAT ITEM) DR DOOR DC ON CENTER "l DWR DRAWER OFF OFFICE -OD OUTSIDE DIAMETER ~ EW EACH WAY (DIMENSION) EA EACH OA OVERALL ~ ELEC ELECTRICAL OBS OBSCURE ELEV ELEVATOR OPNG OPENING EXP EXPANSION OPP OPPOSITE :J! EAG EXHAUST AIR GRILLE "' EJ EXPANSION JOINT "' EWW ELECTRICALLY WELDED Cl,, WIRE MESH PA PLANTING AREA "' El ELEVATlON .., PL YOO PLYWOOD C ENAM ENAMEL PC PUTTY COAT 0 E'l EQUAL :,: EXH EXHAUST PFP PLASTIC FINISH PANEL C EXT EXTERIOR PDC POINT OF CONNECTION "' PTN PARllTION 1: EWC ELECTRIC WATER COOLER PC PIECE :,: FD FLOOR DRAIN PD WO PRESSED WOOD OJ P,l. PROPERTY LINE "' FE FIRE EXTINGUISHER PL PLATE r-FEC FIRE EXTINGUISHER CABINET PLAST PLASTER ~ FF FACTORY FINISH PLAS PLASTIC FFL FINISH FLOOR U) FH FIRE HOSE PNL'G PANELING. Dl POL POLISHED (/j FHC FIRE HOSE CABINET FHw·s FLAT HEAD WOOD SCREW PR PAIR FL FLOW LINE PROP PROPERTY FDC FACE OF CONCRETE (CURB) QT QUARRY TILE R RISER RAG RETURN AIR GRILLE REF REFERENCE REINF REINFORCED REQ REQUIRED RESIL RESILIENT RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN RHWS ROUND HEAD WOOD SCREW RD ROUND OPENING ROW RIGHT OF WAY RAD RADIUS RWD REDWOOD RGTR REGISTER RM ROOM RUB RUBBER SMK DET SMOKE DETECTOR SCHEO SCHEDULE SHR SH0\1£R SHT SHEET SPEC SPECIFICATION , STOR STORAGE SAR SUPPLY AIR REGISTER SC SOLJD CORE SM SHEET METAL SST STAINLESS STEEL S SK SER\ilCE SINK SCR SCREEN SCUP SCUPPER SH SHELF SHTG SHEATHING SIM SIMILAR SQ SQUARE STD STANDARD STL STEEL STRUCT STRUCTURAL SUSP SUSPENDED S'IM SYMMETRICAL T TREAD THK THICK T & B TOP AND BOTTOM T & G TONGUE & GROOVE TC TOP OF CURB TOF TOP OF FOOTING TP TOP OF SIDEWALK (OR PAVEMENT) TOP TOP OF PARAPET GENERAL NOTES 1. THE CONlRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD, SITE COND1110NS, EXISTING TOPOGRAPHY, LOCATION OF UTILITIES, OR ANY SPECIAL FEATURES UNIQUE TO THE SITE AND SHALL REPORT ANY CONFLICTS OR INCONSISTENCIES TO THE ARCHITECT PRIOR TO PROCEEDING \li1TH ANY WORK. THE CONTRACTOR SHALL STAKE OUT THE BUILDING FOR TI-!E ARCHITECT'S AND OWNER'S RE\11EW PRIOR TO PROCEEDING WITI-1 CONSTRUCTION. THE CONTRACTOR SHALL RESOLVE ANY CONFLICTS IN THE CONSTRUCTION DOCUMENTS WlTH THE ARCHITECT BEFORE PROCEEDING WITI, CONSTRUCTION. ANY EQUIPMENT, WORK OR ITEM INDICATED ON THE DRAV\llNGS TO BE N.I.C. (NOT IN CONlRACT) SHALL BE PROVIDED UNDER SOME OTHER CONTRACT OR ARRANGEMENTS BY THE OWNER OR OTHERS. POWER OR UTILITY SUPPLIES AND HOOKUPS SHALL BE PROVIDED BY THE CONTRACTOR TO N.I.C. ITEMS. UNLESS OTHERWISE NOTED, THE CONlRACTOR SHALL ALSO INSTALL N.I.C. ITEMS'PROYIDED BY THE OWNER OR OTHERS. J, ALL MATERIALS & WORKMANSHIP SHALL BE IN COMPLIANCE WITH ALL GOVERNING CODES AND ORDINANCES. INCLUDING TI,E,2007 EDITION OF THE CALIFORNIA BUILDING CODE (TITLE 24), WHICH ADOPTS THE 2006 IBC, 2005 UMC, 2006 UPC, AND TI-1E 2005 NEC. AND SHALL BE IN COMPLIANCE IMTH ALL CURRENTLY ADOPTED OSHA, CITY, COUNTY, STATE, AND NATIONAL STANDA.RDS. 4, WORK IN FURRED AREAS SHALL NOT BE CONCEALED UNllL SUCH WORK HAS BEEN INSPECTED AND APPROVED BY THE INSPECTING AUTHORITIES. IF SUCH WORK IS CONCEALED 'MTHOUT INSPECTION AND APPROVAL, THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ALL WORK REQUIRED TO OPEN AND RESTORE THE CONCEALED AREAS IN ADDITION TO ANY REQUIRED MODIFICAllON TO THE SYSTEM AS WELL AS TO OTHER SYSTEMS. 5, NO CHANGES OR MODIFICATIONS TO THE WORK SHALL BE MADE WITHOUT APPROVAL OF THE OWNER (OR ARCHITECT). FAILURE TO 08TAIN OWNER'S (OR ARCHITECT'S) APPROVAL SHALL CAUSE THE GENERAL CONTRACTOR TO ASSUME FULL RESPONSIBILITY FOR ANY SUBSEQUENT MODIFICATION OF TI-1E WORK REQUIRED BY THE OWNER OR ANY REGULATORY AGENCY, 6. OMISSIONS FROl\,I THE DRAWINGS AND SPECIFICAllONS, OR THE MISDESCRIPTION OF THE WORK WHICH IS MANIFES1LY NECESSARY Td CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY PERFORMED, ·SHALL NOT RELIEVE TI-1E CONTRACTOR FROM PERFORMING SUCH OMITTED OR MISDESCRIBEO DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. 7 WHERE NO DETAILS ARE SHOWN OR N01£.D FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WQRK, NEW OR EXISTING, OR THE ARCHITECT NOTIFIED. WHEN A DETAIL 15 IDENTIFIED AS "TYPICAL", THE CONTRACTOR IS TO APPLY THIS DETAIL IN ESTIMATING AND CONSTRUCTION TO EVERY LIKE CONDITION WHETHER OR NOT TI--lE REFERE;NCE IS REPEATED IN EVERY INSTANCE. 8 DIMENSIONS SHO!M',J SHALL'. TAKE PRECEDENCE OVER DRAWING SCALE OR PROPORTION. LARGER SCALE DRAIMNGS SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. DUE TO REPROGRAPHIC PROCESSES, THESE PLANS MAY NOT 8~ ACCURATE TO SCALE. THEREFORE, THESE PLANS SHOULD NOT BE "SCALED". A. ALL DIMENSIONS ARE ROUGH AND TO STUD L!NE U.N.O. B. ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE VERIFIED IN FIELD BEFORE COMMENCING WORK. NOTIFY ARCHITECT OF 'ANY DISCREPAt'tCIES. C. REFERENCE TO ANY D~TAIL OR DRAWING IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH ,DRAWlNG OR DETAIL. D. THESE DRAWINGS ARE 00NLY REPRESENTATIVE WITH DETAILS TO ASSIST THE CONTRACTOR. DRAWINGS DO NOT ILLUSTRATE EytRY CONDITION. TO RIDGE TOP OF RIDGE ALL SURFACES, STRUCTUR,(IL OR FINISH, WHICH ARE EXPOSED TO YIEW IN THE COMPLETED BUILDING, AND ALL ITEMS OF EQUIPMENT SHALL BE COMPLETELY PROTECTED FROM DAMAGE DURING THE CONSTRUCTION PHASE BY THE CONTRACTOR, WHO SHALL TAKE ALL_ NECESSARY PRECAUTIONS TO INSURE THAT THE PROJECT IS TURNED OVER TO THE OWNER ENTIRELY FREE FROM SCRATCHES. ABRASIONS, DENTS. DRIPS. GOUGES. STAINS. WATER MARKS, PAINT OR OIL RUNS, OR SIMILAR TYPES OF DAMAGE. 'M-lERE'.VER SUCH DAMAGE DOES OCCUR, AND BEFORE THE FINAL INSPECTION OF THE BUILDING BY THE ARCHITECT, TI,E CONTRACTOR SHALL AT NO EXPENSE TO THE OWNER, AND UNDER THE DIRECTION OF THE ARCHITECT, COMPLETELY REPAIR, OR, WHERE REQUIRED, REPLACE THE DAMAGED WORK IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ALL METHODS OF PROTECTION SHALL BE SELECTED BY THE CONTRACTOR. PROTECTION SHALL BE MAINTAINED BY THE CONTRACTOR IN GOOD CONDITION UNTIL EACH ELEMENT SO PROTECTED IS READY FOR THE NEXT PHASE OF THE WORK. OR UNllL IT IS BEING PREPARED FOR FINAL CLEANING. TOR TOO TN TS TOW TEL TEXT THERMO THRESH TYP UON UDS UR U/S U/C VAT VCP VTR VAR vERT YEST W/ W/0 WC W Gl WM WP WPJ WWF WSCT WT WD TOP OF ROOF TOP OF DRAIN TOE NAIL TOP OF SLAB TOP OF WALL TELEPHONE TEXTURE THERMOSTAT THRESHOLD TYPICAL 10. ALL·MATERIALS STORED ON SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE AND DETERIORATION UNTIL USE. FAILURE TO PROTECT MATERIALS MAY BE CAUSE FOR REJECTION OF WORK UNLESS OTHER\l;ISE NOTED 11. ALL TESTING REQUIRED FOR SOIL'COMPACTION, PERCOLATION TESTS, CORING SAMPLES. CONTINUOUS CONCRETE INSPECTIONS, OR OTHER TESTS NECESSARY FOR THE WORK, SHALL BE THE GENERAL CONTRACTOR'S RESPONplBILITY. UNDER OTHER SECTION URINAL UNDERSIDE UNDERSIDE OF CONSTRUCTION 12. THE OWNER HAS BEEN ADVISED THAT SINCE THIS WORK INVOLVES REMODELING OF EXISTING CONOlllONS THAT ARE CONCEALED AND CANNOT BE EXAMINED BY THE ARCHTECT WITHOUT DAMAGE TO THE EXISTING BUILDING, TI,E DETAILS AND METHODS OF REPAIR MAY NEED TO BE ADJUSTED TO INCORPORATE ADDITIONAL ITEMS OF WORK. Tl-iE CONlRACTOR SHALL NOTIFY THE ARCHITECT WHEN SUCH CONDITIONS ARE ENCOUNTERED. A REASONABLE CHANGE IN THE SCOE OF THE WORK WILL THEN BE NEGOllATED. \ilNYL ASBESTOS TILE VITREOUS CLAY PIPE VENT THRU ROOF VARNISH VERTICAL VESTIBULE v,m WITHOUT WATER CLOSET WlRE GLASS WlRE MESH WATERPROOF WEAKENED PLANE JOINT WELDED WIRE FABRIC WAINSCOT WEIGHT WOOD 1J. PLANS IDENTIFIED AS "BID str· OR "PRqGRESS SET -NOT FOR CONSTRUCTION" ON ANY OR ALL SHEETS MAY BE SUBJECT TO REVIEW BY THE ARCHITECT, OR OTHERS SUCH AS THE BUILDER, BUILDING INSPECTION DEPARTMENT, ETC. TI-115 RE\ilEW MAY RESULT IN CHANGES WHICH MAY BE MADE TO THE PLANS PRIOR TO ISSUANCE OF THE FINAL CONSTRUCTION SET WHICH 'NILL CONTAIN NO SUCH DESIGNATIONS 14. THE ARCHITECT SHALL IN NO WAY BE R~SPONSIBLE FOR HOW TI--lE FIELD WORK IS PERFORMED, SAFETY IN, ON, OR ABOUT THE JOBSI~, METHODS OF PERFORMANCE, OR TIMELINESS IN THE PERFORMANCE OF THE WORK. ANY PERIODIC VISITS TO THE JOBSITE BY THE ARCHITECT ARE SOL.ELY FOR THE PURPOSE OF DETERMINING COMPLIANCE WITH THE lECHNICAL PROVISIONS OF THE CONTRACT DOCUMENTS. ~¥'_,,-~LL IDEAS. DESIGNS, ARRANGEMENTS OF PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY. AND ARE THE PROPERTY OF THE ARCHITECT, AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON. AND IN CONNECTION WITH THIS SPECIFIC PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OF PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE 'M--JATSOEVER WITHOUT THE ~ITTEN PERMISSION OF-THE ARCHITECT. BUILDING ADDRESS NUMBERS SHALL BE EASILY SEEN FR0 SUBSTITUTION OF "EQUAL" OR "EQUIVALENT" PRODUCTS WILL BE ACCEPTABLE ONLY WITH THE ARCHITECT'S OR OWNER'S WRITIEN RE\ilEW. INDEMNIFICATION: CONTRACTOR SHALL PROTECT AND SAVE HARMLESS THE OWNER AND ARCHITECT FROM ALL CLAIMS, ACTIONS OR DAMAGES OF EVERY KIND AND DESCRIPTION WHICH MAY ACCRUE TO, OR BE SUFFERED BY. ANY PERSON OR PERSONS, CORPORATION OR PROPERTY BY REASON OF THE PERFORMANCE BY THE CONTRACTOR OF THE WORK UNDER THIS CONTRACT, CHARACTER OF MATERIAL USED OR MANNER OF INSTALLATION, OR BY THE IMPROPER OCCUPANCY OF RIGHTS-OF-WAY OR PUBLJC PLACES. WITH THE OWNER -OORS, WINDOWS, APPLIANCE,S, PLUMBING, LIGHTING, ETC., SHALL BE VERIFIED 23. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SIGNING ANY AND ALL CERIFICATES OF COMPLIANCE IF REQUIRED BY THE STATE OF CALIFORNIA OR ANY OTHER CERTIFICATES REQUIRED BY LOCAL OR COUNTY ORDINANCES. SYMBOLS I ehest ElUILDING SECTION WINDOW LETTER CD DOOR NUMBER eren cllrectron EXIT SIQN /r------l=Jxture Quantlt!:j '/• ~z---~ Fixture T~ps ' \j# Watta9e per Fixture Ll,:;,HT FIXTURE NUMElER Elevation Sheet INTERIOR ELEVATIONS NEW i EXISTING WALL TYPE + ELEVATION TM <'--~> KEYNOTE TM DETAIL VICINITY MAP filTE ADD!i!Eefi, &4e,4 l"Aei&O DEL NO!i!TE C:ARL.fieAD, C:AL.IFORNIA e2C!IC!l8 rl'sf!'· .. ·'•'· ., -,cs;, L (I,,' ··q;;;r)Y' PROJECT DESCRIPTION THE &c0A: OF 11.()f'iK INCLUDE&, l'<EMODELING, AND EXF,l,NSION OF THE EXISTlit:; SERVICE ADVl50FIS FAqlLITY AT THE 50UTH·EAST CORNER OF THE MAIN BUILDllt:;. THE EXPANSION WILL BE CONSTRUCTED UNDER THE EXISTING, SERVICE DRIVE ROOF AND SHALL CON515T OF A NEW STORE:ff«.JNT SYSTEM WITH A STUCCO WALL ABOVE, NEW CONcl':ETE SLAB AND FOUNDATION, EXTENSION OF THE EXISTING, MECHANICAL SYSTEMS, AND ADDITICNAL Llc;HTINGo AND POU.ER TO SERVE THE ADDITION. A NEW LAY -IN CEILINCii, NEW INTERIOR F'ARTITION&, AS 11.!:LL A& NEW ACCE551BLE COUNTERS AND 11.()f'iK STATION& Al':E INCLUDED IN THE 5COF'E OF II/OlsK. EXISTING. TITL~·24 ACCE5&1BLE 1':E5TROOM5 SHALL &ERVE THE l':EMODEL AND ADDITION. ENERGY CONSERVATION SEE 'M' 5HEET5 FOR ENEl'<GY CON&ERYATION 1':EGUll':EMENT5. Oll.llll!lii! I c::oNT Ac::T, PROJECT DATA flOEf.N A550CIATE6 PO aox 169 CA!<LS6AD, CALIFOl<t,IIA !3201!> CONTACT, RICK eL.l>J<EMOl'<E (160) 43!>-1818 I.EGAL C>EeCl,ilFtlON, A~, &IT! Aq.ti, , toNI, Gl!IJl!l'IAL. fOLAN ~TION, OCCUPANC'\", C::ON&Tlli!UC::TION TYi"!!, ,~Iii! Alli!&A, VALUATION OI' AOOITION, $4$4 PAeEO DEL NORTE CARl..ef3AD, CALIFO!<NIA, ~200& F'ARCEL 2 OF F'ARCEL MAF' llh&l 211-12)60-1~ GROee, 3.115 ACF!ES (138.3<!>3 S.F) NET, 2.864 ACF!E6 /124,156 6.F J C·2 (llf'-19/ fl. /F!EGIONAJ. COMMERCIAL! MAIN EIUILDll'I:., f3 EXISTll'I:. i F'FiOPO&ED, V·N MAN 191..00. EX16Tll'I:., F'FWPOSED, TOT AL MAN f3LOO, eEF!.VICE BUILDll'I:. 'A' eEF!.YICE EIUILDll'I:. '6' ALLQII/ED, CURRENT, F'ROF'05ED, LE55 Tf.lAN 160J!X!X!).i!0 6;,00 5F 6}:,0f) 5F 34p16 eF 31~24 6F 31~24 6F AT-I A-5F'·I A·5F'·2 A-I.I A-1.2 A-2.1 A·2.2 A-3.1 6-1.1 5·1.2 6·13 5-1.4 5-2.1 M-1.1 SHEET INDEX TITLE SHEET ARCHITECiURAL &F'ECIFICATIONS ARCHITECilJRAL 5F'ECIFICATIONS SITE F'LAN DRAINAGi!: • EROSION CONT!<OL F'LAN . -· ... FLOOR I ELECTRICAL f'L,l,N • INTERIOR ELEVATIONS l':El'LECTED CEILING! F'LAN • DETAILS, DOOR SCHEDULE SOUTH EXTERIOR ELEVATION I BUILDING! SECTION ST,l,NDARD STRUCTURAL DETAILS, 6Ci-lEDULE5 • SF'EClflCATIONS STANDARD STRUCTURAL DETAILS, ecHEDULES i SF'EClflCATIONS 5TANDARD 5TRUCTURAL DETAIL&, 6CI-IEDULE5 I 8F'ECIFICATION5 5Tl'il.lCilJRAL DETAILS FOUNDATION F'LAN I ROOF FRAMING! f'L,l,N TITLE-24 ENEl'<GY CONSULTANTS TITI.E 24 I ~'\" BURKET! I WONG, Tl<M MECHANICAL 3434 FOJRTH A VENUE SAN DIEGO, CA 52103 TEL, /619! 299-55!;0 CONTACT, F'AUL l<LINClENBEi-6 648 LUCYLLE L,l,NE OLIVENHAIN, CA 92024 TEL, /161Z>/ 153·4102 CONTACT, TOM MARSHALL SPECIAL INSPECTION Ol&IGN &mlNGTH 51MPSON &ET EPOXY ICC E&R 1112 DISABLED ACCESe CITY OF CARL&eAD EllJILD NC. IN&F'ECTION DIVISION HAZARDOUS MATERIALS USED GILIANTIT'\" NIA NIA NIA NIA NIA HOEHN HONDA Service Advisors Remodel & Addition Car Country Carlsbad California 8-12·/!lll F'LAN CHECK 1':EVISION5 10-8-08 F'LANNING,/ENG,INEER'C!i l':E5F'ON&E5 BOKAL & SNEED ARCHITECTS 244 Ni11tr1 Street Del Mar. California 92014 [858) 481 8244 Fax (858] 481 8364 All ideas, designs, and arrangements indicated on these drawings are the property of Bokal & Sneed Architects and are intended to be used in conriedion with this specific project only and shall not otherwise be used for any purpose whatsoever without the written consent of Bokal & Sneed Architects. There shall be no ch<mqes or deviations from these drawings or the accompanying specificolions without the written consent of Bokal & Sneed Architects. Minor Coastal Development Permit (CDP 08-19) Sheet Title TITLE SHEET Scale NOTED Dote l0·1HZ>6 Drawn M1'iN * Checked RDB No. C 8417 Job No. IZ>132 AT-1 I I " ij I a ~! .~c ~s !a ~ en . ,1J • 'ii> j~z zm IC~ <I m~ ~"m ffi ID• ':~~ I t I I I I I I I I t ro ! ro ~ Cl ll ):, I ~· -2 Cl 2 C: s OJ m :a .CJ ll ~ 2 Cl 2 C: s OJ m lJ ----------------------------------------- ' '~ e,',~v~~-., V ,--,,-.,',~.;,.,.,'< S,~ '" XI < ' i " ' \ ' ' \ ' I ' I I i 8 Oisplay Spaces '', ,: i Servi~ SpaceS; ' 10 • i I . ·· ·· ·· ·· · · ·I·· . ·· ·· ··, ~ I,., 0 ' 9 "hsplay s._paces : ~· 5 Sel'Vl. . ce Spa_ ces I ,;, V • 0 +--,( ---;--~~--+-: --,-~-----,-~--t---tt-)l(~~-------,.------,----,,)i: < .. ~ ~ I I "'i:"' ;·~\,,.,:,,,,. O ,-/,_.,/' PT··· iJ I I I \ (E) Driveway I I -'I<----i /~. LU ti: 0 z ...J LU Cl @ ~ CL I I \ ,, " .. ·.· i " ' I I \. I• I ~·.•. ' ' < " ., ~ 'e ', I ' I ' \· .. ·." . . . ',' ,. I ' · ... \ '\1, \' I I \ I I (E) Light Standard, Typ. ' " / / ,,, ' 6 :Display! Space$ (E) Driveway 24'-0" J '-------------------------------- See Reflected Ceiling'. Plan and Electrical (Floor) Plan for Illuminated Exit Si9ns. E9 •• ""'","'<''""' E9 SITE PLAN Scale: 1 "=20' F'. I ii i '" 1:¥'1 , ., ~-1 OFFICE 115sf/100• 1 occ OFFICE 158 sf/ 100 • 2 occ B Occupancy SERVICE ADVIS0•=~-11 664 sf/ 1~-'====U 7 occ FIRE EGRESS PLAN Scale: 1 "=1 O' I I I I I I I I I .. Landscape • 7 $howroom/-Patio [?isplay Spaces : (E) MAIN BUILDING LJ.17c" (E} Accessible Path of Travel ---------1 (E) Accessible Restrooms . I ':"''<' ,,',L .:: ,,,, "-~ '.,, .. ~ '"•,c" Fire Department Note: The proposed addition will not Limltof,~i~ o, i.mpede Fire Department access. ., ...... ,, I '. •7_ ------ Parking Tabulation Req'd belore Addition Sales (10,660 sf existing+ 425 sf addition) 1 space per 400 sf gross floor area Customer (20'.l/o of required stalls) Employee (80o/o of required stalls) Service (Repair) (36 bays existing and proposed) First 3 Bays (Four per Bay) Additional Bays (Two per Bay) Parts (4,240 sf existing and proposed) Customer (1 space per 1,000 sf) Employee (1 space per 1,250 sf) Storage & Display (including 7 Showroom) Total Service (Repair) Parking Spaces Total Customer Parking Spaces Total Employee Parking Spaces Total Service, Customer and Eployee Spaces Total Parking Spaces (incl. Storage & Display) (6) (21) (12) (66) (4) (3) 27 78 7 78 10 24 112 " Handicap parking included in Employee and Customer parking spaces. (E) Pedestrian Walk Req'd with Addition (6) (22) (12) (66) (4) (3) 28 78 7 78 10 25 113 I"'" (E) Drive;AisJe 25'-1P" :'444,;.Je-Area of Remodel (cross-hatchep) 1 i I ' ill ' ! I I ' I (E) Concrete Wheel Stop, Typical (E) SERVICE BUILDING "A" I I i I (E) Dri~e AISie 40(0" t i ' f lf'"'·"'"""'"'"'·''·"'"''"'"="'""'" ''""'="'="""'"·'""'""= l ij ' & ' ' 1 ' . ' I ' ' ' ' ,1-, ' i ' 1 (E) SERVICE BUILDING "B" ' ( E) Drive Aisle ( 26'-0" i . I I ,," ................ · I I I .I I I C}· I I .... ··, I I I ···· 1 I ·a--.......... , " I I I ······· I I ·, I ., •• ,'... . .. J-(E) Lig~ Standard, Typ. I ..... I I I ,<..~~-2-Se~M_·_ce~• _s_pa_c_e_s~~-->'.·-~~~..,,_ ,( 7 : .I"·: 22'-0" Typ. Parallel S1all 5 ·se't\lice Sp~ces )r', .. . ',~'( ~~----- ' ' Provided (6) (25) 28' 78 7 60 78 10 25 113 173 9'-6" Typ. 1' 1' Driveway (E) Concrete Wheel Stop, Typical APPROVED 13 S~rvice Sp~ces • • v· .. v····•·c.,,--.. 1} i ,\_. ! THIS IS THE APPROVED TENTATIVE MAP/SITE PLAN PER CONDITION NO. ~ID'===- V~¥.~~~__l/.l'...:t~D~O A1=TE gN~E~ 5(Jf :J I') ,,,_' ~ <.: ~o -E ~ Cl "' w l j{J : ' (E) Concrete Wheel ·,. ···~ :l. ' (.:_ (/) . $ I , E ' ... J.U ., Stop, Typical-==--,..:: I I : I . I . I HOEHN HONDA Service Advisors Remodel & Addition Car Country Carlsbad California 8-12-t!ll FLAN °"1:CK REYl510N5 BOKAL & SNEED ARCHITECTS 244 Nir1tt1 Street Del Mar. Caifomia 92014 [858) 481 8244 fax 1858] 48 1-8364 All ideas, designs, and arrangements indicated on these drawings are the property of Bokal & Sneed Architects and are intended to be used in connection with this specific project on~ and shall not otherwise be used for any purpose whatsoever without the writte11 co11sent of Bokal & Sneed Architects. There shall be no changes or deviations from these drawings or the accompanying specifications without the written 1qonsent of Bokal & Sneed )\rchi\ects. Minor Coastal Development Permit (CDP 08-19) Sheet Title SITE PLAN & FIRE EGRESS PLAN Scole NOT!:D Date IIZ>-8-IZ>8 Drawn Mi.N Checked RD6 No. C 8417 Job No. IZ>132 A-1. 1 I I I I '{! I ~, O;, TI ~"' mo joo ~c !I 93 ~ it .~ Cl) ". ~~ 1~z ~E~ • ~a i it! 1:1 i ~f11, f ~i! z I I I I I I I I I I l § 'ii CJ :c ~ 2 Gl 2 C: s:: CJ m :0 C I 2 m 2 i! Ill 171 :0