HomeMy WebLinkAboutPDP 00-02C; AGUA HEDIONDA SEWER LIFT STATION; Site Plan' ' ' ,
l
' '
;
EXISTING
48" SEWER
BEGIN PROPOSED
RECYCLED WATER
CONSTRUCTION
CONNECT TO EXISTING
10"WATER
EXISTING JUNCTION STRUCTURE
LOCATION OF TEMPORARY BY-PASS PUMPING EQUIPMENT
RELOCATE EXISTING 8" SEWER LATERAL
-
__ ., ____ .., ___ v--++-~----------V
• ____ RW•
r-,.,. •• , ---I --;"l,VW _____ _
RW
EXISTING A. T. & S.F.
RAILROAD RNV
MH No. 15
RW RW
PROPOSED 6" WATER SERVICE
EXISTING
12"HPGAS
PROPOSED 12"
RECYCLED WATER LINE
------
"ti ... l_ RW---'---RW----V ._,
YMCA AQUATIC CENTER
---------====-------,,,_ _.., -------=-------.. -= = = = = = = ----------RW RW~=~~lf~::;;;;;;;;;;3'.;;;;;;;;;;;;;;:;~:::::;~~ ----------
==I=-=== ---------===--------== --------RW _/iR~-~--------==============--------~~--RW'____ "..1..-_ ------=-= c::::
-=
BEGIN PROPOSED = = = = -= -= ---
SEWER CONSTRUCTION
==--==------------=:ic:;==-=:m:-=-=::.::::m: ----=== .::::.:::c = =,.._ --~ --=-~ --.. .,, -=-"::I,, .::r--EARTHEN RAVINE =---.. c:r --.:=----------EXISTING G A.T. &S.F.
ABANDONED
SEWER
ABANDON
EXISTING
3" WATER
EXISTING
48" SEWER
BEGIN PROPOSED
RECYCLED WATER
CONSTRUCTION
CONNECT TO EXISTING
10"WATER
LAYDOWN
AREAS
ROAD Rm EXIST 42" SEWER (ABANDON)
EXISTING JUNCTION STRUCTURE
LOCATION OF TEMPORARY BY-PASS PUMPING EQUIPMENT
RELOCATE EXISTING 8" SEWER LATERAL
l
' ___ -------~--,--
----EXISTING --1
BEGIN
PRO~OSED SEWER
CONSTRUCTION
I
EXISTIN"G A.T. & S.F.
'
LEGEND:
ABANDONED
SEWER
ABANDON
EXISTING-
3"WATER
PROPOSED RECYCLED WATER (OPEN TRENCH CONSTRUCTION)
PROPOSED 6" WATER LINE REPLACEMENT OF EXISTING 3" WATER
PROPOSED SEWER
EXISTING SEWER TO REMAIN
EXISTING SEWER TO BE ABANDONED OR REMOVED
EXISTING ABANDONED SEWER
RAILROAD RNV EXIST 42" SEWER (ABANDON)
TEMPORARY CONSTRUCTION FENCING
,..,. __ _ EXISTING OVERHEAD TELEPHONE
EXISTING OVERHEAD ELECTRICAL
G-EXISTING GAS
.. s EXISTING SEWER
w-EXISTING WATER
EXISTING STORM DRAIN
TEMPORARY 24" ABOVE GRADE
BY-PASS PUMPING FORCE MAIN
PROPOSED 54" ID GRAVITY SEWER
------r -
NCTD RAILROAD
EXISTING A.T. & S.F.
RAILROAD RNV OPEN TRENCH CONSTRUCTION (ALL UTILITIES
BY-PASS PUMPING
PHASE 2 (VC11B)
EXISTING A. T. & S.F.
RAILROAD RNV
PROPOSED 6" WATER SERVICE
MH No. 15
TEMPORARY 24" ABOVE GRADE
BY-PASS PUMPING FORCE MAIN
PROeOSED -54" ID GRAVITY SEWER
PROPOSED GRADING (FILL)
EXISTING A. T. & S.F. J ---
RAILROAD RNV
EXISTING
12"HP GAS
I
PROPOSED12"
RECYCLED WATER LINE
-----=====-----------------------------
E THEN RAVINE
Nern RAILROAD
, t V "'"-• l41 -s,r~
EXISTING 12" HP GAS TEMPORARY CONSTRUCTION FENCING I? ' '
RELOCATED 12"HPGAS
EXISTING 12" HP GAS TO BE REMOVED
TEMPORARY 24" BYPASS FORCE MAIN
TEMPORARY 42" SEWER
~ LAYDOWN AREA
\IJ PROPOSED MANHOLE
J (,,'61 7
• •? ~ ,;;-31 -/3
-----
MH No.14
PROPOSED RELOCATION OF
EXISTING 12" HP GAS LINE
YMCA AQUA TIC CENTER
LAYDOWN AREA
-----
MH No.14
PROPOSED RELOCATION OF
EXISTING 12" HP GAS LINE
0 20 .0
SCALE: 1• -.O'
BROWN AND CALDWELL
9665 Chesapeake Drive, Suite 200
Sim Diego, Co.. 92123
w ·~ _J
::c (.)
~ ~
w
IZ
I~ .~ .~
I
PDP 00-02 (C) I SP 144 (L) / RP 10-26/
CDP 10-17 I HOP 10-05 / SUP 10-02/
HMP 10-03
SHEITNAME
PL-06
fsiiml CITY OF CARLSBAD ~ ENGINEERING DEPARlMENT
~ ~
PROPOSED IMPROVEMENTS
AGUA HEDIONDA SEWER LIFT STATION. FORCE MAIN.
AND GRAVITY SEWER REPLACEMENT PROJECT
0
'"TJ
•