Loading...
HomeMy WebLinkAboutPDP 00-02C; AGUA HEDIONDA SEWER LIFT STATION; Site Plan' ' ' , l ' ' ; EXISTING 48" SEWER BEGIN PROPOSED RECYCLED WATER CONSTRUCTION CONNECT TO EXISTING 10"WATER EXISTING JUNCTION STRUCTURE LOCATION OF TEMPORARY BY-PASS PUMPING EQUIPMENT RELOCATE EXISTING 8" SEWER LATERAL - __ ., ____ .., ___ v--++-~----------V • ____ RW• r-,.,. •• , ---I --;"l,VW _____ _ RW EXISTING A. T. & S.F. RAILROAD RNV MH No. 15 RW RW PROPOSED 6" WATER SERVICE EXISTING 12"HPGAS PROPOSED 12" RECYCLED WATER LINE ------ "ti ... l_ RW---'---RW----V ._, YMCA AQUATIC CENTER ---------====-------,,,_ _.., -------=-------.. -= = = = = = = ----------RW RW~=~~lf~::;;;;;;;;;;3'.;;;;;;;;;;;;;;:;~:::::;~~ ---------- ==I=-=== ---------===--------== --------RW _/iR~-~--------==============--------~~--RW'____ "..1..-_ ------=-= c:::: -= BEGIN PROPOSED = = = = -= -= --- SEWER CONSTRUCTION ==--==------------=:ic:;==-=:m:-=-=::.::::m: ----=== .::::.:::c = =,.._ --~ --=-~ --.. .,, -=-"::I,, .::r--EARTHEN RAVINE =---.. c:r --.:=----------EXISTING G A.T. &S.F. ABANDONED SEWER ABANDON EXISTING 3" WATER EXISTING 48" SEWER BEGIN PROPOSED RECYCLED WATER CONSTRUCTION CONNECT TO EXISTING 10"WATER LAYDOWN AREAS ROAD Rm EXIST 42" SEWER (ABANDON) EXISTING JUNCTION STRUCTURE LOCATION OF TEMPORARY BY-PASS PUMPING EQUIPMENT RELOCATE EXISTING 8" SEWER LATERAL l ' ___ -------~--,-- ----EXISTING --1 BEGIN PRO~OSED SEWER CONSTRUCTION I EXISTIN"G A.T. & S.F. ' LEGEND: ABANDONED SEWER ABANDON EXISTING- 3"WATER PROPOSED RECYCLED WATER (OPEN TRENCH CONSTRUCTION) PROPOSED 6" WATER LINE REPLACEMENT OF EXISTING 3" WATER PROPOSED SEWER EXISTING SEWER TO REMAIN EXISTING SEWER TO BE ABANDONED OR REMOVED EXISTING ABANDONED SEWER RAILROAD RNV EXIST 42" SEWER (ABANDON) TEMPORARY CONSTRUCTION FENCING ,..,. __ _ EXISTING OVERHEAD TELEPHONE EXISTING OVERHEAD ELECTRICAL G-EXISTING GAS .. s EXISTING SEWER w-EXISTING WATER EXISTING STORM DRAIN TEMPORARY 24" ABOVE GRADE BY-PASS PUMPING FORCE MAIN PROPOSED 54" ID GRAVITY SEWER ------r - NCTD RAILROAD EXISTING A.T. & S.F. RAILROAD RNV OPEN TRENCH CONSTRUCTION (ALL UTILITIES BY-PASS PUMPING PHASE 2 (VC11B) EXISTING A. T. & S.F. RAILROAD RNV PROPOSED 6" WATER SERVICE MH No. 15 TEMPORARY 24" ABOVE GRADE BY-PASS PUMPING FORCE MAIN PROeOSED -54" ID GRAVITY SEWER PROPOSED GRADING (FILL) EXISTING A. T. & S.F. J --- RAILROAD RNV EXISTING 12"HP GAS I PROPOSED12" RECYCLED WATER LINE -----=====----------------------------- E THEN RAVINE Nern RAILROAD , t V "'"-• l41 -s,r~ EXISTING 12" HP GAS TEMPORARY CONSTRUCTION FENCING I? ' ' RELOCATED 12"HPGAS EXISTING 12" HP GAS TO BE REMOVED TEMPORARY 24" BYPASS FORCE MAIN TEMPORARY 42" SEWER ~ LAYDOWN AREA \IJ PROPOSED MANHOLE J (,,'61 7 • •? ~ ,;;-31 -/3 ----- MH No.14 PROPOSED RELOCATION OF EXISTING 12" HP GAS LINE YMCA AQUA TIC CENTER LAYDOWN AREA ----- MH No.14 PROPOSED RELOCATION OF EXISTING 12" HP GAS LINE 0 20 .0 SCALE: 1• -.O' BROWN AND CALDWELL 9665 Chesapeake Drive, Suite 200 Sim Diego, Co.. 92123 w ·~ _J ::c (.) ~ ~ w IZ I~ .~ .~ I PDP 00-02 (C) I SP 144 (L) / RP 10-26/ CDP 10-17 I HOP 10-05 / SUP 10-02/ HMP 10-03 SHEITNAME PL-06 fsiiml CITY OF CARLSBAD ~ ENGINEERING DEPARlMENT ~ ~ PROPOSED IMPROVEMENTS AGUA HEDIONDA SEWER LIFT STATION. FORCE MAIN. AND GRAVITY SEWER REPLACEMENT PROJECT 0 '"TJ •