HomeMy WebLinkAboutPalm Engineering Construction Company Inc; 2015-03-10; PWS15-44UTIL (4)APPENDIX D POTHOLING REPORTS 1. Project #X130038 dated May 14, 2013 2. Project #X130082-84 dated August 26, 2014 3. Project #X130126 dated November 1,2014 4. Project #X140037 dated April 9, 2014 REPORT FOR City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008-7314 Attn: Sherri Howard Sherri.Howard@carlsbadca.gov PROJECT #X130038 Report date: 05/14/2013 City Capital Project Potholing for Existing Utilities Grand Avenue Improvements Carlsbad, California TABLE OF CONTENTS 1. Introduction 2. Project Description and Comments 3. Google Map / Pothole Layout 4. Tabulation Report 5. Test Hole Data Sheets PREPARED BY AIRX UTILITY SURVEYORS, INC. 2534 EAST EL NORTE PARKWAY, UNIT C ESCONDIDO, CA 92027-3751 www.airxus.com INTRODUCTION AIRX Utility Surveyors performs a full range of specialized engineering services including Underground Utility Location and Vacuum Excavation (to verify depth and alignment of underground utilities). Underground Utility Location employs sophisticated electronic locating devices to trace the route of an underground utility; then the route is marked on the surface with marking paint in paved areas, or with 60 penny nails and feathers in unpaved areas. Vacuum excavation employs a vacuum truck in conjunction with high-pressure air or water to excavate material and expose an underground utility. A 12 to 18 inch diameter hole is first cored or chiseled through the pavement so that the vacuum hose and high pressure air or water hose can be inserted. Utilities found during potholing are located on the surface by placing two reference points (typically 36" apart) on either side of the pothole along the centerline (or edge) of the utility, using paving nails or 60 penny nails as appropriate. Depth measurements (to the nearest Vi inch) are taken midway between the two reference points. Utility alignment, depth, and other data is marked with pink paint (on pavement), or on wood lath (unpaved areas). PROJECT DESCRIPTION AND COMMENTS AirX was retained by Sherri Howard, Associate Engineer ofthe City of Carlsbad to verify depth and location of utilities on Grand Avenue in Carlsbad, CA. The information obtained will assist design work forthe proposed NW Quadrant Storm Drain Project (No.6608). In preparation of these excavations, AirX marked out the dig locations and called in for USA (Underground Service Alert). In order to verify the alignment, which had changed, Steve Tueting with AirX did two job walks with Sherri Howard from the City of Carlsbad. In the report everything that runs in line with Grand Avenue is being labeled as E/W, and everything that directly crosses Grand Avenue is labeled as N/S. The first job walk was to verify pothole locations, as several potholes were clearly a distance from the proposed alignment. The second was to critique the pothole locations after the alignment had been shifted and the designer from RBF was present to answer questions and note conflicts. Traffic control plans and permits were drawn and applied for by AirX. No parks were set as required by the city. The original start date of the project was set back a week due to a Cinco de Mayo event in downtown Carlsbad,rainy weather also contributed to the delayed start time. There were abandoned fire hydrant service laterals and sections of 10" ACP water pipe along Grand Avenue. The AirX crews spent four days with the use of hydro-excavation equipment potholing for utilities. Any utilities found in the potholes that were in addition to the utilities originally requested have been photographed and documented and are included on the data sheets. At the request of the City Inspector, AirX crews pressure washed the USA mark out off of the sidewalks and utilized a coring machine to cleanly cut through the decorative brick in the intersection of State Street and Grand Avenue. AirX used potable water obtained offsite for excavation, and all water and material vacuumed up was disposed of offsite; no water was allowed to fiow into storm drains or natural drainage. The potholes were covered with clean backfill material and compacted to 95% density in 3" lifts. The pavement was patched with an equal thickness of replacement asphalt. All potholing was performed from May 8, 2013 to May 13, 2013. • JEFFERSON ST -1 iigaHsaas I laaHS aas aNn HOivw oo'oo-i-9 vxs miJk 0 £-1 3 .0 <2 z CO 2 «- cj o o I' s « C n 0 o m c ^ E o o o^ E a, CD a. Q < o S z Ul 3 Z Hi a z o O u. z o I- 3 m < o X s o9 o a. C3 CL ft! 0- " CD b or o O o; I- (0 irl tu O! W Q: or UJ LU LU 1-ELECT 1-< < ELECT < g S ELECT 5 f I £ E < CK! Q lUI > 5! ffi CD Q: COI lU o I C3 tu LI « Rl < u a' < m <n _i < o CD O tc a. '•S C •5 - E 1 o t: o m E if Q s oc o H CO Q < I) O 3 z lii 3 Z UJ 5 (3 Of O 3 3 o X I-o a. o n £ E CO 2 > tr a: LU, UJ UJ S 5 § RECORD OF TEST HOLE DATA AlFiXJOBNO: X130033 TEST HOLE NO; 1 DATE DUG: 05/08/2013 UTILITY TYPE Electric Water SIZE & IVIATERIAL Slurry Encasement 10.0" ACP UTILITY DEPTH 32.0" T/P ENCASEIl/IENT TOP 6.0" T/E ENCASEMENT BOTTOM 33.5" B/E UTILITY DIRECTION EW NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Slurry Sand COMMENTS: Pothole 1 was excavated in tiie street in front of 421 Grand Ave. This pothole required a lane shift and a trench was visible prior to digging. The electrical slurry encasement was found at a depth of 6.0' T/E to 33.5" B/E and travels E/W. It is assumed that the encasement wraps the water PVC pipe.. The measurement of 33.5 is to the bottom of the PVC. o RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 2 DATE DUG; 05/08/2013 UTILITY TYPE Water street Light SIZE & MATERIAL 10.0" ACP 1.5" steel UTIUTY DEPTH 43.5" T/P 38.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION E/W N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand COMMENTS: Area view looking southwest at pothole 2. The street lights were marked out on the street but did not show up on the as-built maps. The 1.5" steel street light conduit was found travelling N/S at a depth of 38.0" T/P. Also, the 10.0" ACP water pipe was found travelling E/W at 43.5" T/P. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO: 3 DATE DUG: 05/08/2013 UTILITY TYPE Water Storm Drain SIZE & MATERIAL 10.0" ACP 4.0" PVC UTILITY DEPTH 48.0" T/P 15.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION E/W N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL: OVERBURDEN MATERIAL: No COMMENTS: Photo taken looking northwest on Grand Avenue towards State Street. A lane shift was set up to minimize traffic interference. The 4.0" PVC storm drain pipe vras found at a deplh of 15.0" T/P and travels N/S. The 10.0" ACP water pipe was found at 48.0" T/P and travels E/W RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 4 DATE DUG; 05/08/2013 UTILITY TYPE Street Lights SIZE & MATERIAL 2.0" PVC UTILITY DEPTH 12.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand Sand COMMENTS: Two potholes are in this area shot. Pothole 4 is at the right. This pothole was excavated at the edge of a previously dug micro-trench. Picture was taken looking southeast. The 2.0" PVC street light conduit was found at a depth of 12.0" T/P and travels N/S. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 5 DATE DUG; 05/08/2013 UTILITY TYPE Water Water SIZE & MATERIAL (2) 1.5" PVC 6.0" Steel UTILITY DEPTH 24.0" T/P 51.5" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand Sand COMMENTS: Pothole 5, which is the hole on the left side of the photo, is at the edge of the decorative brick. Down the hole view at pothole 5 where 2 separate water utilities were found. On the left side of the photo a 6.0" steel water pipe was found at 51.5" T/P, and at 24.0" T/P, the (2) 1.5" PVC water pipes were found. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 6 DATE DUG; 05/13/2013 UTILITY TYPE Electric SIZE & MATERIAL Concrete Encasement UTILITY DEPTH ENCASEMENT TOP 55.5" T/E ENCASEMENT BOTTOM 65.0" B/E UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION 3" DECORATIVE BRICK - OVER 1" SAND - OVER 6" CONCRETE UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No Sand Sand Picture was taken looking northwest at the intersection of State Street and Grand Avenue. In order to preserve the decorative bricks, the crew cored through the bricks prior to jac* hammering the concrete below. Pothole 6 is 25'5" away from the pillar on the left. The electrical concrete encasement that was found in pothole 6 runs in the same direction as State Street (N/S). It was found at a depth of 55.5" T/E to 55.0" B/E. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 7 DATE DUG; 05/13/2013 UTILITY TYPE Water SIZE & MATERIAL Utility not found UTILITY DEPTH ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/A APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: CONCRETE: 12.0" BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No Clay Clay COMMENTS: Picture taken looking west. Pothole 7 was measured 144" east of pothole 6. This is at the intersection of Grand Avenue and State Street. In an attempt to get a depth on a water utility, the crew dug to a depth of 76.0" and probed to 125.0". They also dug 36" wide and did not find any utilities. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 8 DATE DUG; 05/08/2013 UTILITY TYPE Traffic Signal Electric SIZE & MATERIAL 3.0" PVC Concrete Encasement UTILITY DEPTH 13.0" T/P ENCASEMENT TOP 45.5" T/E ENCASEMENT BOTTOM 55.0" B/E UTILITY DIRECTION E/W N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 1.0" CONCRETE CAP: 10" UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL: OVERBURDEN MATERIAL; No Native / Sand Native / Sand COMMENTS: Picture taken looking northwest with pothole 8 in view. The pothole was excavated at the edge of a micro-trench. The 3.0" PVC traffic signal conduit was found at a depth of 13.0 T/P under a 10" thick concrete cap. The concrete encasement was found at a depth of 45.5" T/E to 55.0" B/E. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 9 DATE DUG; 05/08/2013 UTILITY TYPE Water SIZE & MATERIAL 10.0" ACP UTILITY DEPTH 48.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION E/W APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; Dirt / Sand OVERBURDEN MATERIAL; Dirt / Sand COMMENTS: Area view looking north west towards State Street. Pothole 9 was dug in front of the parking spaces reserved for 519 Grand. The 10.0" ACP water pipe was found at a depth of 48.0" T/P and travels E/W. o RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 10 DATE DUG; 05/08/2013 UTILITY TYPE Electric SIZE & MATERIAL Concrete Encasement UTILITY DEPTH ENCASEMENT TOP 46.0" T/E ENCASEMENT BOTTOM 54.0" B/E UTILITY DIRECTION E/W APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL: Concrete OVERBURDEN MATERIAL: Dirt / Sand Picture taken looking towards State Street from Grand Avenue. The pothole was dug at the edge of the decorative bricks. Down the hole view at pothole 10. The electrical concrete encasement was found at a depth of 46.0" T/E to 54.0" B/E. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 11 DATE DUG; 05/08/2013 UTILITY TYPE 1 Time Wamer Cable 2 3 4 SIZE & MATERIAL 2.0" PVC UTILITY DEPTH 21.0" T/P ENCASEMENT TOP ENCASEMENT UTILITY BOTTOM DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Dirt / Sand Dirt / Sand COMMENTS: Pothole 11 is just east of the walkway between State Street and Roosevelt Street on Grand Avenue. The 2.0" PVC Time Warner Cable conduit was found at a depth of 21.0" T/P and travels N/S. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 12 DATE DUG; 05/08/2013 UTILITY TYPE Water SIZE & MATERIAL 10.0" ACP UTILITY DEPTH 41.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Native / Sand Native / Sand COMMENTS: Area view looking northwest towards the entry of the parking lot to the side of Sea Wave Salon. Access was temporarily blocked to this parking lot and a lane shift was set up on Grand Avenue. At a depth of 41.0" T/P, the crew found the 10.0" ACP water pipe travelling N/S across Grand Avenue. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 13 DATE DUG; 05/08/2013 UTILITY TYPE Sewer SIZE & MATERIAL 8 0" VCP UTILITY DEPTH 136.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL: OVERBURDEN MATERIAL; No Native / Sand Native / Sand Picture taken looking west in the direction of State Street. There were a series of five potholes excavated within a few feet of each other on neighboring utilities. The 8.0" VCP sewer pipe was found in pothole 13 at a depth of 126.0" T/P and travels N/S. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 14 DATE DUG; 05/09/2013 UTILITY TYPE Gas SIZE & MATERIAL 2.0" Steel UTILITY DEPTH 33.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 4.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No Native Native COMMENTS: Area view looking north across Grand Avenue. This pothole is near pothole 15, which is in front of the Sea Waves Salon. At a depth of 33.0" T/P and travelling N/S, the crew found a 2.0" steel gas line. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO: 15 DATE DUG; 05/09/2013 UTILITY TYPE AT&T SIZE & MATERIAL 3.0" PVC UTILITY DEPTH 42.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 4.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No Native Native Pothole 15, which is located on the left side of this photograph, is just west of the Sea Waves Salon, on Grand Avenue. At a depth of 42.0" T/P. the aew found the 3.0" PVC AT&T conduit heading N/S. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 16 DATE DUG; 05/09/2013 UTILITY TYPE Water SIZE & MATERIAL 10.0" ACP UTILITY DEPTH 47.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION E/W APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL: Dirt / Sand OVERBURDEN MATERIAL: Dirt / Sand COMMENTS: Area view looking south across Grand Avenue. Pothole 16 is in the diagonal partying in front of O'lreland. No parks were required. The 10.0" ACP water pipe was found at a depth of 47.0" T/P and heads E/W. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 17 DATE DUG; 05/09/2013 UTILITY TYPE 1 Water - Hydrant 2 Traffic Signal 3 4 SIZE & MATERIAL 6.0" ACP 2.0" PVC UTILITY DEPTH 48.0" T/P 12.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S E/W APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 2.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; Dirt / Sand OVERBURDEN MATERIAL; Dirt / Sand COMMENTS: Pothole 17 is located north of the fire hydrant in front of The Grand Deli. This Deli is located on the southwest Cramer of Roosevelt and Grand. The water pipe that services the fire hydrant was found running N/S at a depth of 48.0" T/P. This ACP pipe was measured at 6.0" in diameter. The 2.0" PVC traffic signal conduit was found travelling EA/V at a depth of 12.0" T/P. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 18 DATE DUG; 05/10/2013 UTILITY TYPE Sewer SIZE & MATERIAL 12.0" CIP UTILITY DEPTH 178.5" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 7.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No Sand Sand 9 Area view looking north on Roosevelt Street across Grand Avenue. Pothole 18 required three lane shifts. At a depth of 178.5" T/P the crew found the 12.0" CIP sewer pipe travelling N/S. RECORD OF TEST HOLE DATA AIRX JOB NO: X130038 TEST HOLE NO; 19 DATE DUG; 05/10/2013 UTILITY TYPE Water SIZE & MATERIAL 8.0" PVC UTILITY DEPTH 49.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTIUTY DIRECTION APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 7.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand Sand COMMENTS: This picture was taken from the south side of Grand Avenue looking north. This pothole was excavated in an area that had previously been trenched. The 8.0" PVC water pipe was found at a depth of 49.0" T/P and travels N/S. At this end of Grand the ground was softer sand. As the project moves east, the ground becomes more tightly packed. c RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 20 DATE DUG; 05/10/2013 UTILITY TYPE AT&T - FO SIZE & MATERIAL (5) 4.0" PVC UTILITY DEPTH PACKAGE TOP 25.0" T/PKG PACKAGE BOTTOM 34.0" B/PKG UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand Sand COMMENTS: Area picture showra the alignment of the fiber optic package that crosses Grand Avenue at the Roosevelt Intersection. A total of (5) 4.0" PVC AT&T fiber optic conduits were found at a depth of 25.0" (T/PKG) to 34.0" (B/PKG) and these pipes mn N/S. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 21 DATE DUG; 05/10/2103 UTILITY TYPE Electric SIZE & MATERIAL Concrete Encasement UTILITY DEPTH ENCASEMENT TOP 30.5" T/E ENCASEMENT BOTTOM 47.5" B/E UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Concrete Sand COMMENTS: A series of several potholes were excavated in the intersection of Roosevelt and Grand Avenue. Pothole 21 is at the bottom of the picture. The probe in the picture was used to get a solid measurement on the bottom of the electrical concrete encasement. The dimension of the encasement are listed above. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 22 DATE DUG; 05/09/2013 UTILITY TYPE Street Lights Street Lights SIZE & MATERIAL 2.0" PVC 3.0" PVC UTILITY DEPTH 12.0" T/P 11.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION E/W N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand Sand Pothole 22 was excavated in the southeast comer of Grand Avenue and Roosevelt Street. This picture was taken looking northwest. Down the hole view at pothole 22 where two separate street light conduits were found. The 3.0" PVC was at 11.0" T/P and the 2.0" PVC was at 12.0" T/P. o RECORD OF TEST HOLE DATA AIRX JOB NO: X130038 TEST HOLE NO; 23 DATE DUG; 05/13/2013 UTILITY SIZE & UTIUTY ENCASEMENT ENCASEMENT UTILITY TYPE MATERIAL DEPTH TOP BOTTOM DIRECTION Street Lights 2.0" PVC 13.0" T/P E/W Gas 1.0" Steel 27.0" T/P N/S Water 1.0" Copper 36.0" T/P N/S APPROXIMATE NORTHING EASTING GROUND UTILITY STATION COORDINATES COORDINATES ELEVATION ELEVATION PAVEMENT THICKNESS: ASPHALT: 3.0" CONCRETE: BASE COURSE: UTIUTY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand Sand Pothole 23 is located at approximate stationing 9-I-55. Three utilities were found at this location. At a depth of 13.0" T/P the 2.0" street light conduit was found travelling EA/V. The other two utilities are heading N/S across Grand Avenue. This includes the 1.0" steel gas line at 27.0" T/P and the 1.0" copper water line at 36.0" T/P. o RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 24 DATE DUG; 05/09/2013 UTIUTY TYPE Water SIZE & MATERIAL 10.0" ACP UTIUTY DEPTH 46.5" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION EA/V APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Sand Sand COMMENTS: Pothole 24 was excavated on ESE bound Grand Avenue in the second diagonal parking stall extended into the street. No ground water was found in this pothole, the water in the photo is from the potholers jet. The 10.0" ACP water pipe was found travelling E/W. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 27 DATE DUG; 05/09/2013 UTILITY TYPE Unknovm SIZE & MATERIAL 3.0" PVC UTIUTY DEPTH 33.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTIUTY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLftN: Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL; Dirt / Roots OVERBURDEN MATERIAL; Dirt / Roots COMMENTS: Area view looking north across Grand Avenue. In order to excavate pothole 27, the crew set up no parks on the south side of Grand. The crew was not able to confirm what utility was in a 3.0" grey PVC pipe that travels N/S in pothole 27. This conduit was found at 33.0" T/P and is suspected to be an electrical conduit. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 29 DATE DUG; 05/09/2013 UTILITY TYPE Gas Water Service SIZE & MATERIAL 3/4" Steel 3/4" Copper UTIUTY DEPTH 29.0" T/P 50.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTIUTY SHOWN ON PLAN: COMMENTS: Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Dirt/Sand Dirt / Sand Pothole 29 was excavated on Grand Avenue at the west end of Chase Bank. Two utilities were found in pothole 29. The 3/4" copper water service pipe was found at 50,0" T/P and the 3/4" steel gas pipe was found at 50.0" T/P. Both utilities travel N/S. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 30 DATE DUG; 05/09/2013 UTILITY TYPE Water SIZE & MATERIAL 6.0" ACP UTILITY DEPTH 40.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 4.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Native / Sand Native / Sand Photo taken looking south towards Chase Bank. Pothole 30 wras dug just north of the fire hydrant. This area has previously been trenched. The 6.0" ACP water line was found at a depth of 40.0" T/P and travels N/S. o RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 32 DATE DUG; 05/10/2013 UTILITY TYPE Electrical Unknown SIZE & MATERIAL 4.0" PVC 2.0" PVC UTIUTY DEPTH 43.0" T/P 26.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTIUTY DIRECTION N/S N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 8.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Native Native COMMENTS: Pothole 32 was excavated in the intersection of Madison Street and Grand Avenue. This photo was taken looking east. An unidentified 2.0" white PVC pipe was found at a depth of 26.0" T?P. Also, at a depth of 43.0" T/P. the crew found a 4.0" electrical conduit. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 33 DATE DUG; 05/10/2013 UTILITY TYPE Time Wamer SIZE & MATERIAL 2.5" PVC UTILITY DEPTH 27.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 4.0" CONCRETE: BASE COURSE: UTIUTY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL; Dirt / Sand OVERBURDEN MATERIAL; Dirt / Sand COMMENTS: Pothole 33 is the pothole at the right in the photo. A visible trench was dug prior to our potholing. This picture was taken looking south down Madison Street between the bank and the dentist office. The 2.5" Time Wamer Cable PVC conduit was found travelling N/S at a depth of 27.0" T/P in pothole 33. o RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 34 DATE DUG; 05/10/2013 UTILITY TYPE Gas SIZE & MATERIAL 1.5" Steel UTIUTY DEPTH 33.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTIUTY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL; Dirt / Sand OVERBURDEN MATERIAL; Dirt / Sand COMMENTS: SDG&E locators mark out can be clearly seen mnning N/S across Grand Avenue at Madison Street. Pothole 34 is the hole at the bottom of the photo. The crew uncovered tie 1.5" steel gas line at a depth of 33.0" T/P. The utility mns N/S. o RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 35 DATE DUG; 05/10/2013 UTILITY TYPE Sewer Main SIZE & MATERIAL 8.0" VCP UTIUTY DEPTH 104.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; Dirt / Sand OVERBURDEN MATERIAL; Dirt/Sand Pothole 35 was one in six that were excavated in the intersection of Madison Street and Grand Avenue. The 8.0" VCP sewer main was found at a depth of 104.0" T/P and travels N/S. RECORD OF TEST HOLE DATA AIRX JOB NO; X130038 TEST HOLE NO; 36 DATE DUG; 05/10/2013 UTILITY TYPE Water SIZE & MATERIAL 12.0" PVC UTILITY DEPTH 47.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No Native Native COMMENTS: Area view looking west on Grand Avenue at the Madison Street intersection. Pothole 36 was dug at the southeast comer of this intersection. The 12.0" PVC water pipe was found travelling N/S at a depth of 47.0" T/P. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 37 DATE DUG; 05/10/2013 UTILITY TYPE ATT SIZE & MATERIAL 2.0" PVC UTILITY DEPTH 26.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: 2.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Native Native COMMENTS: This photo was taken looking north across Grand Avenue at the intersection of Madison Street. Pothole 37 is on the right side of the picture. At a depth of 26.0" T/P the crew located a 2.0" PVC AT&T conduit headed N/S across Grand Avenue. o RECORD OF TEST HOLE DATA AIRX JOB NO; XI30038 TEST HOLE NO; 39 DATE DUG; 05/10/2013 UTILITY TYPE Gas SIZE & MATERIAL 3/4" Steel UTILITY DEPTH 53.0" T/P ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION EAA/ APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: ASPHALT: CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No Dirt / Asphalt Chunks Dirt / Asphalt Chunks COMMENTS: This picture was taken looking south towards the dental office at the intersection of Madison Street and Grand Avenue. The pothole is marked with a wooded post. The 3/4" steel gas line (wrapped in grey tape) was found at a depth of 53.0" T/P and heads E/W. REPORT FOR City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008-7314 Attn: Sherri Howard Sherri.Howard@carlsbadca.gov PROJECTS #X130082-84 Report date: 08/26/2013 Northwest Quadrant Storm Drain Improvement Project Potholing for Existing Utilities Linda Lane/Basswood Avenue/Grand Avenue Carlsbad, California TABLE OF CONTENTS 1. Introduction 2. Project Description and Comments 3. Carlsbad Project Map (Areas 1-5) 4. Area 1 - Linda Lane/South Cul-de-sac (PH 103,105-106) 5. Area 2 - Linda Lane/North Cul-de-sac (PH 101-102) 6. Area 3 - Grand Avenue/State Street (PH 201 -205) 7. Area 4 - Grand Avenue/Madison Street (PH 206-208) 8. Area 5 - Basswood Avenue (PH Bl -B3, B5) 9. Tabulation Report (Areas 1-5) 10. Record of Test Hole Data Sheets (Linda Lane) 11. Record of Test Hole Data Sheets (Grand Avenue) 12. Record of Test Hole Data Sheets (Basswood Avenue) PREPARED BY AIRX UTILITY SURVEYORS, INC. 2534 EAST EL NORTE PARKWAY, UNIT C ESCONDIDO, CA 92027-3751 www.airxus.com Page 1 of 3 INTRODUCTION AIRX Utility Surveyors performs a full range of specialized engineering services including Underground Utility Location and Vacuum Excavation (to verify depth and alignment of underground utilities). Underground Utility Location employs sophisticated electronic locating devices to trace the route of an underground utility; then the route is marked on the surface with marking paint in paved areas, or with 60 penny nails and feathers in unpaved areas. Vacuum excavation employs a vacuum truck in conjunction with high-pressure air or water to excavate material and expose an underground utility. A 12 to 14 inch diameter hole is first cored or chiseled through the pavement so that the vacuum hose and high pressure air or water hose can be inserted. Utilities found during potholing are located on the surface by placing two reference points (typically 36" apart) on either side of the pothole along the centerline (or edge) of the utility, using paving nails or 60 penny nails as appropriate. Depth measurements (to the nearest inch) are taken midway between the two reference points. Utility alignment, depth, and other data are marked with pink paint on the pavement in the pothole area. PROJECT DESCRIPTION AND COMMENTS AirX was originally retained in May 2013 by Sherri Howard, Associate Engineer of the City of Carlsbad to verify depth and location of utilities on both Highland Drive, Basswood Avenue and Linda Lane in Carisbad, CA. The information obtained was to assist design work for the proposed Northwest Quadrant Storm Drain Improvement Project (No.6608). Between June 21-27 2013 AirX excavated 20 potholes on Linda Lane and 8 potholes on Highland Drive for project total of 28 potholes. All data collected was Submitted in report format on July l"2013. AirX was contacted by Sherri Howard in late July 2013 to provide additional utility locating and potholing services for the Northwest Quadrant Storm Drain Improvement Project. In preparation of these excavations, AirX marked out the dig locations and called in for USA (Underground Service Alert). In order to verify the alignment, Steve Tueting of AirX completed a pre-dig walkthrough with Sheri Howard. Traffic control plans and permits were drawn and applied for by AirX. No parks were set as required by the city. All potholing was performed between August 14-19 2013 using hydro-excavation equipment. Any utilities found in the potholes that were in addition to the utilities originally requested have been photographed and documented and are included on the data sheets. A total 17 potholes were excavated during this project on three different streets in city of Carlsbad; Linda Lane (5 potholes; PH 101-103,105-106), Grand Avenue (8 potholes; PH 201-208) and Basswood Avenue (4 potholes; PH B1-B3, B5). Specific observation include the moving of potholes 201 and 203 on Grand Avenue approximately one foot SW from the original locations in order to preserve existing decorative pavers and still locate utilities within 0 Page 2 of3 o the pothole area. Unfortunately the utility layout for pothole 202 did not allow the pothole location to be moved off of decorative pavers. On Basswood Avenue the alignment of the pipe was unclear so a plan was crafted to emulate slot trenching to find it initially at one location. Pothole B3 was to be excavated first and if unsuccessful B4 wouid be opened. At B3 the pipe was found and therefore B4 was not used. The pipe was found at the other locations Bl, B2 and B5 although the pipe alignment is not parallel with the curb. AirX used potable water obtained offsite for excavation, and all water and material vacuumed up was disposed of offsite; no water was allowed to flow into storm drains or natural drainage. The potholes were covered with clean backfill material and compacted to 95% density in 3" lifts. The pavement was patched with an equal thickness of replacement asphalt. o Page 3 of3 CD PO ca CO in IN 00 ro en X Q. z n -D c m CO o fM 1 i LU 1 'i o CL a. < LLI < z o H < o _J LU _I o X 1- o Q. ^I-I. I rH 1 1 3: < 1 CO 1 UJ 1 1 1 —1 1 D 1 U 1 X 1 1-1 ^ \ 0 1 Z 1 *^ 1 LLl 1 z 1 A LA 1 < 1 Q 1 Z 1 -J 1 • i < 1 UJ 1 ^ 1 ^ in tN i o CM a 1 1 1 < o d < CD <n _i < ill HI - 2 3 2 31; Q- o S J o O. O Sl S E ? E 5 z •5 M Q. > < to Hi" ! :3 a s a, y ; ni z I ^ - 'it i < 2 •5 <" OT -< ^ cu " S- -» 1 ^ 'X 2 o a. " 5 o ra z z g z z ° «I •= § . §3 W g -g CM « « ra 15 0) •a - ,2 " £ ra t «| l^i o « J <0 O >, J3 C « "> O 0) (0 ra Q. —I if c <u o ra c .i -2 1^ i < tn OT S < ra ra > E S •= V o ^ • » ai IS UJ (0 <n I z z 1 i H E E T3 c CO a o • — %; ram •22 ' CO c z i a. *- o To w ^ > m < C8 CL O ; 2 5 - = Q. O T5 Q. IN • 5y " Q] 0} to :fc I "S O O , .£ CSI Q. 1 1 ra W <° OT -.S < TO *- O ra « Q Q i ! - E < o Q < CQ <n _i < o o ^11 s '5 i go p £ S 5 T a. E 5 E 2 S H !S . g a. •= o < z i £ E O 3 a. z a. ra < cfl • m < 5 o (U CO Q 2 IS g 5 cn ul z 1 a. (0 « CO < RECORD OF TEST HOLE DATA AIRX JOB NO: X13083 TEST HOLE NO: 101 DATE DUG: 08/14/2013 UTILITY TYPE SIZE & MATERIAL UTILITY DEPTH ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION CATV (TWC) 1.0" PVC 25.0" T/P N/A N/A NW/SE Electric 2.0" PVC 35.0" T/P N/A N/A NW/SE Water (Service) 3/4" Copper 39.0" T/P N/A N/A ENE/WSW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL: N/A OVERBURDEN MATERIAL: Native Soil COMMENTS: c Area photo of pothole 101, located In the northem cul-de-sac of Linda Lane approximately 15 feet west of the curb/driveway for 2094 Linda Lane. This photo was taken standing in the cul-de-sac and looking north towards 2084 Linda Lane A down hole view of the 3 utilities found in pothole 101. At a depth of 25 inches T/P a 1.0" PVC CATV (TWC) was found immediately above a 2 inch PVC electric utility that was at a depth of 35 inches T/P. A 3/4" copper water (service) pipe was also found at a depth of 39 inches T/P running in an ENE/WSW direction at the pothole location. All utilities were found within the mari<out area and cross each other approximately 12 inches east of the pothole location. RECORD OF TEST HOLE DATA UTILITY TYPE Gas SIZE & MATERIAL 1.5" Steel APPROXIMATE STATION NORTHING COORDINATES AIRX JOB NO: X13083 TEST HOLE NO: 102 DATE DUG; 08/14/2013 UTILITY DEPTH 36.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NNW/SSE EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil Located in the northem cul-de-sac of Linda Lane, pothole 102 is approximately 10 feet NE ofthe curb (to the NE of 2064 Linda Lane). Photo was taken from that curb while looking NE towards 2094 Linda Lane. Pothole 101 is also visible in front of the driveway for 2094 Linda Lane and pothole 4 (from June 2013 work) is also visible approximately 8 feet north of pothole 102. A down hole view of the 1.5" steel gas line found at a depth of 36 inches T/P in pothole 102. The utility mns in a NNW/SSE direction at the pothole location as was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X13083 TEST HOLE NO; 103 DATE DUG; 08/14/2013 UTILITY TYPE Gas (Service) SIZE & MATERIAL 3/4" Steel UTILITY DEPTH 38.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NNW/SSE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil COMMENTS: An area photo of pothole 103, located in the southern cul-de-sac of Linda Lane, specifically, it is approximately 25 feet north of the curt) in front of 2075 Linda Lane. Photo was taken from in front of 2075 Linda Lane and looking NW towards 2095 linda Lane. Pothole 9 (from June 2013 wori<) is also visible approximately 25 feet to the NW of pothole 103. A down hole view of the 3/4" steel gas line found at a depth of 38 inches T/P. The utility was found within the maricout area and travels in a NNW/SSE direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO; X13083 TEST HOLE NO; 105 DATE DUG; 08/14/2013 UTILITY TYPE Gas (Service) SIZE & MATERIAL 3/4" Steel UTILITY DEPTH 32.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NNW/SSE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 4.0" ASPHALT: 4.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL: Native Soil COMMENTS: An area photo of pothole 105, located approximately 100 feet SW of the "T" intersection on Linda Lane. Specifically pothole 105 located 4 feet SW of the property line between 2055 and 2065 Linda Lane and 6 feet NW off the curt). Photo was taken from Linda Lane and looking SE towards 2055 and 2065 Linda Lane. A close up view of the 3/4" steel gas line found at a depth of 32 inches T/P. The utility was found directly on mari^out and travels in a NNW/SSE direction at the pothole location (perpendicular with street) RECORD OF TEST HOLE DATA AIRX JOB NO; X13083 TEST HOLE NO; 106 DATE DUG; 08/14/2013 UTILITY TYPE Gas (Service) SIZE & MATERIAL 3/4" Steel UTILITY DEPTH 30.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; NO PIPE COVER MATERIAL: N/A OVERBURDEN MATERIAL; Native Soil COMMENTS: o An area photo of pothole 106, located approximately 6 feet SW ofthe property line between 2035 and 2045 Linda Lane. The photo was taken from Linda Lane and looking SE towards 2035 and 2045 Linda Lane. A close up view of the 3/4" steel gas line found at a depth of 30 inches T/P. The utility was found directly on mari^out and travels in a NNW/SSE direction at the pothole location (perpendicular with street) RECORD OF TEST HOLE DATA AIRX JOB NO; XI30082 TEST HOLE NO; 201 DATE DUG: 08-15-13 UTILITY TYPE Water SIZE & MATERIAL 4.0" PVC UTILITY DEPTH 20.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 7.0" ASPHALT: 7.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil Area shot of pothole 201 located in left SW bound lane of Grand Ave approximately 18 feet SW ofthe intersection with State Street. Photo was taken from SW bound lane looking NE. Close up view of 4 inches PVC water utility found in pothole 201 at the depth of 20 inches T/P. Utility was found directly on mari<out and runs NW/SE direction at the pothole locatio. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30082 TEST HOLE NO; 202 DATE DUG; 08-19-13 UTILITY TYPE Telephone SIZE & MATERIAL MTD UTILITY DEPTH N/A ENCASEMENT TOP 43.0" T/E ENCASEMENT BOTTOM 53.0" B/E UTILITY DIRECTION NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 12.0" ASPHALT: CONCRETE: 12.0" BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL MTD OVERBURDEN MATERIAL: Native Soil COMMENTS: Area shot of pothole 202 located in left SW bound lane of Grand Ave approximately 7 feet SW from State Street. Photo was taken from SW bound lane looking NE. o Close up view of MTD telephone utility found in pothole 202. MTD was found at 43 inches T/E and 53 inches B/E. Utility was found approximately 2 feet NE from original markout and ains NW?SE direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO; X130082 TEST HOLE NO; 203 DATE DUG; 08-15-13 UTILITY TYPE Sewer SIZE & MATERIAL 36.0" VCP UTILITY DEPTH 120.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 13.0" ASPHALT: CONCRETE: 13.0" BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil Area shot of pothole 203 located in left SW bound lane of Grand Ave at the SW intersection with State Street. Photo was taken standing in the NE bound lane of Grand Ave looking NW. Close up view of 36 inch VCP sewer utility found at pothole 203 at the depth of 120 inches T/P. Utility was found approximately 1 foot NW from markout area and mns NE/SW direction. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30082 TEST HOLE NO; 204 DATE DUG: 08-15-13 UTILITY TYPE Water SIZE & MATERIAL 10.0" ACP UTILITY DEPTH 53" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 12.0" ASPHALT: CONCRETE: 12.0" BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; YM PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil COMMENTS: o Area shot of pothole 204 located approximately 15 feet NE from center of Grand Ave and State Street intersection. Photo was taken looking from SW Grand Ave. Close up view of 10 inch ACP water utility found in pothole 204 at the depth 53 inches T/P. Visible in the hole is tracer wire. Utility was found within the markout area and mns in NW/SE direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30082 TEST HOLE NO; 205 DATE DUG; 08-14-13 UTILITY TYPE Water SIZE & MATERIAL 12.0" ACP UTILITY DEPTH 56.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 18.0" ASPHALT: CONCRETE: 18.0" BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; Yes PIPE COVER MATERIAL: N/A OVERBURDEN MATERIAL; Native Soil COMMENTS: Area shot of pothole 205 located in left NW bound lane of Grand Ave at the SE intersection with State Street. Photo was taken standing in NW bound lane looking SE. Down hole view of 12 inches ACP water utility found in pothole 205 at the depth of 56 inches T/P. Visible in the hole is tracer wire. Utility was found directly on mari^out and mns NW/SE direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO; X130082 TEST HOLE NO; 206 DATE DUG; 08-14-13 UTILITY TYPE Water SIZE & MATERIAL 12.0" ACP UTILITY DEPTH 44.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN: Yes Yes Yes TFRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil COMMENTS: o Area shot of pothole 206 located in NE bound lane of Grand Ave on the opposite side of 550 Grand Ave approximately 25 feet from nearest driveway. Photo was taken standing in the driveway looking at 550 Grand Ave. Down hole view of 12 inches ACP water utility found in pothole 206 at the depth of 44 inches T/P. Utility was found directly on mari<out and runs NW/SE direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO: X130082 TEST HOLE NO; 207 DATE DUG; 08-14-13 UTILITY SIZE & UTILITY ENCASEMENT ENCASEMENT UTILITY TYPE MATERIAL DEPTH TOP BOTTOM DIRECTION 1 Unknown 2.0" PVC 24.0" T/P N/A N/A NE/SW 2 Electric 3.0" PVC 45" T/P N/A N/A 3 Electric 4.0" PVC 44.0"T/P N/A N/A 4 APPROXIMATE NORTHING EASTING GROUND UTILITY STATION 1 COORDINATES COORDINATES ELEVATION ELEVATION 2 3 4 PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil Area shot of pothole 207 located in NE bound lane of Grand Ave 5 feet from curb and the driveway at 725 Grand Ave. Photo was taken standing in NE bound lane of Grand Ave looking SW. Close up view of the utiities found in pothole 207. A 2 inches PVC Unknown utility was found at depth of 24 inches T/P. A 3 inches electric utility was found at depth of 45 inches T/P and 4 inches electric utility was found at depth of 44 inches T/P. Utilities were found directly on markout and mn NE/SW direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO; X130082 TEST HOLE NO; 208 DATE DUG; 08-14-13 UTILITY SIZE & UTILITY ENCASEMENT ENCASEMENT UTILITY TYPE MATERIAL DEPTH TOP BOTTOM DIRECTION 1 Electric 3.0" PVC 43.0" T/P N/A N/A N/S 2 Water 12.0" ACP 48,0" T/P N/A N/A NE/SW 3 Telephone (ATT) 2.0" PVC 31.0" T/P N/A N/A N/S 4 APPROXIMATE NORTHING EASTING GROUND UTILITY STATION 1 COORDINATES COORDINATES ELEVATION ELEVATION 2 3 4 PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; "No PIPE COVER MATERIAL: N/A OVERBURDEN MATERIAL: Native Soil COMMENTS: o Area shot of pothole 208 located in NE bound lane of Grand Ave approximately 35 feet from pothole 207 at 725 Grand Ave. Photo was taken standing in NE bound lane of Grand Ave looking SW. Close up view of the utiities found in pothole 208. A 3 inches PVC electric utility was found at depth of 43 inches T/P. A 12 inches ACP water utility was found at depth of 48 inches T/P and 2 inches PVC telephone (ATT) found at depth of 31 inches T/P. Utilities were found directly at markout. 3 and 2 inches pipes mn N/S direction. 12 inches pipe mns NE/SW direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30084 TEST HOLE NO; Bl DATE DUG; 08-16-13 UTILITY TYPE Water SIZE & MATERIAL 6,0" ACP UTILITY DEPTH 43,0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL OVERBURDEN MATERIAL; No N/A Sand Area shot of pothole Bl located in NE bound lane of Basswood Ave at the transition with James Dr and approximetaly 15 feet from the curb at east side of intersection. Photo was taken standing in NE bound lane of Basswood Ave looking NE, Close up view of the 6 inches water utility found in pothole Slat the depth of 43 inches T/P. Utility was found directly on mari^out and mns NE/SW direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO; X130084 TEST HOLE NO; B2 DATE DUG; 08-16-13 UTILITY TYPE Water SIZE & MATERIAL 6,0" ACP UTILITY DEPTH 45.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No N/A Sand COMMENTS: Area shot of pothole B2 located in NE bound lane of Basswood Ave at the 1635 Basswood Ave. Photo was taken standing in NE bound lane of Basswood Ave looking SE. Close up view of the 6 inches water utility found in pothole B2 at the depth of 45 inches. Utility was found approximately 1 foot SE from the mari<out area and and runs NE/SW direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO: X130084 TEST HOLE NO; B3 DATE DUG; 08-16-13 UTILITY TYPE Water SIZE & MATERIAL 6.0" ACP UTILITY DEPTH 28.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PU\N; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL No N/A Sand Area shot of pothole B3 located in NE bound lane of Basswood Ave on the opposite side of 1660 Basswood Ave. Photo was taken standing in NE bound lane of Basswood Ave looking SW. Close up view of 6 inches water utility found in pothole B3 at the depth of 28 inches T/P, Utility was found approximately 1 foot SE from the mari^out area and mns NE/SW direction at the pothole location. RECORD OF TEST HOLE DATA AIRX JOB NO: XI30084 TEST HOLE NO; B5 DATE DUG: 08-16-13 UTILITY TYPE Water SIZE & MATERIAL 6,0" ACP UTILITY DEPTH 25.5" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: BASE COURSE: UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No N/A Sand COMMENTS: Area shot of pothole B5 located in NE bound lane of Basswood Ave at the 1695 Basswood Ave. Pothole is located approximately 30 feet from intersection with Valley Street Photo was taken standing in NE bound lane of Basswood Ave looking NE, Close up view of 6 inches ACP utility found in pothole B5 at the depth of 25,5 inches T/P, Utility was found approximately 3 feet SE from mari<out area and mns NE/SW direction at the pothole location. 1.1 R V F Y 0 R S REPORT FOR City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008-7314 Attn: Sherri Howard Sherri.Howard@carlsbadca.gov PROJECT #X130126 Report date: 11/1/2013 Northwest Quadrant Storm Drain Improvement Project Potholing for Existing Utilities, Round 3, Grand Avenue Carlsbad, California TABLE OF CONTENTS 1. Introduction 2. Project Description and Comments 3. Grand Avenue Project Map 4. Pothole Area Map 5. Tabulation Report (PH 401-409) 6. Record of Test Hole Data Sheets (PH 401 -409) PREPARED BY AIRX UTILITY SURVEYORS, INC. 2534 EAST EL NORTE PARKWAY, UNIT C ESCONDIDO, CA 92027-3751 www.airxus.com Page 1 of2 o o INTRODUCTION AIRX Utility Surveyors performs a full range of specialized engineering services including Underground Utility Location and Vacuum Excavation (to verify depth and alignment of underground utilities). Underground Utility Location employs sophisticated electronic locating devices to trace the route of an underground utility; then the route is marked on the surface with marking paint in paved areas, or with 60 penny nails and feathers in unpaved areas. Vacuum excavation employs a vacuum truck in conjunction with high-pressure air or water to excavate material and expose an underground utility. A 12 to 14 inch diameter hole is first cored or chiseled through the pavement so that the vacuum hose and high pressure air or water hose can be inserted. Utilities found during potholing are located on the surface by placing two reference points (typically 36" apart) on either side ofthe pothole along the centerline (or edge) of the utility, using paving nails or 60 penny nails as appropriate. Depth measurements (to the nearest inch) are taken midway between the two reference points. Utility alignment, depth, and other data are marked with pink paint on the pavement in the pothole area. PROJECT DESCRIPTION AND COMMENTS AirX was originally retained in May 2013 by Sherri Howard, Associate Engineer ofthe City of Carlsbad to verify depth and location of utilities on Grand Avenue between the North County Transit Railroad crossing and Madison Street in Carlsbad, CA. The information obtained was to assist in design work for the proposed Northwest Quadrant Storm Drain Improvement Project (No.6608). Between October 24''*' to 31" 2013 AirX excavated 7 potholes on Grand Avenue in the street (near the tracks) and planter areas along the south side of Grand Avenue. All data collected was Submitted in report format on November f * 2013. In preparation of these excavations, AirX marked out the dig locations and called in for USA (Underground Service Alert). In order to verify the alignment, Steve Tueting of AirX completed a pre-dig walk-through with Sheri Howard. Traffic control plans and permits were drawn and applied for by AirX. No parks were set as required by the city. Traffic control was set up by AirX and potholing was allowed by the city on all days except Wednesday when the Farmer's Market is in operation between Roosevelt and Madison Streets. All of the excavations were successful with the exception of potholes PH403 and PH408 which were not excavated. All of the pertinent data was marked on the street and has been incorporated in this report. AirX used potable water obtained offsite for excavation, and all water and material vacuumed up was disposed of offsite; no water was allowed to flow into storm drains or natural drainage. The potholes were covered with clean backfill material and compacted to 95% density in 3" lifts. The pavement was patched with an equal thickness of replacement asphalt. Page 2 of 2 as o t^^^gstmm.m£s^6^SI^^''^ 1 X QL illi 1 • ] o RECORD OF TEST HOLE DATA AIRX JOB NO: XI30126 TEST HOLE NO; 401 DATE DUG; 10-30-13 UTILITY TYPE 1 Water Service 2 3 4_ APPROXIMATE STATION 1 2 3 4 SIZE & MATERIAL 1.0" Copper UTILITY DEPTH 36.0" T/P ENCASEMENT TOP N/A NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION ENCASEMENT BOTTOM N/A UTILITY DIRECTION NW/SE UTILITY ELEVATION PAVEMENT THICKNESS: 18.0" ASPHALT: 18.0" CONCRETE: N/A BASE COUF^SE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No N/A Clay COMMENTS: Pothole 401 is located In SW bound lane of Grand Avenue approximately 10 feet NE from the right tum to Carisbad Village Station. The photo was taken standing in front of pothole 401 and 402 looking NE. A close up view of 1 inch copper water utility found in pothole 401 at the depth of 36 inches TIP. Utility runs in NW/SE direction at the pothole location and was found directly on mari<out. RECORD OF TEST HOLE DATA AIRX JOB NO; X130126 TEST HOLE NO; 402 DATE DUG; 10-30-13 UTILITY TYPE Electric SIZE & MATERIAL 2.0" Steel UTILITY DEPTH 30.5" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 7.5" ASPHALT: 7.5" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL: OVERBURDEN MATERIAL: No NfA (Stay COMMENTS: o Pothole 402 is located in SW bound lane of Grand Avenue approximately 16 feet NE from the right tum to Carlsbad Village Station. The photo was taken standing in front of pothole 401 and 402 looking NE. A close up view of 2 inch steel electric utility found in pothole 402 at the depth of 30.5 inches T/P. Utility runs in NW/SE direction at the pothole location and was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO: X130126 TEST HOLE NO: 404 DATE DUG: 10-30-13 UTILITY TYPE Water SIZE & MATERIAL 1,0" Copper ATT Concrete Encasement UTILITY DEPTH 28,0" T/P N/A ENCASEMENT TOP N/A 30,0" T/P ENCASEMENT BOTTOM N/A 45.0" B/E UTILITY DIRECTION NE/SW NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: N/A ASPHALT: N/A CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No N/A Clay COMMENTS: Pothole 404 is located approximately 2 feet NE from the curb of NW bound lane of Roosevelt Street, Pothole is located in front of 2906 Roosevelt Street. The photo was taken standing in front of pothole 404 looking NW. A close up view of 1 inch copper water utility found in pothole 404 at the depth of 28 inches T/P. Utility mns in NE/SW direction at the pothole location and was found directly on mart<out. RECORD OF TEST HOLE DATA 1 2 3 4 UTILITY TYPE ATT Electric APPROXIMATE STATION SIZE & MATERIAL Concrete Encasement Concrete Encasement NORTHING COORDINATES UTILITY DEPTH N/A N/A EASTING COORDINATES AIRX JOB NO; XI30126 TEST HOLE NO; 405 DATE DUG; 10-28-13 ENCASEMENT TOP 27,0" T/E 35,0" T/E GROUND ELEVATION ENCASEMENT BOTTOM 48,0" B/E N/A UTILITY ELEVATION UTILITY DIRECTION NW/SE NW/SE PAVEMENT THICKNESS: N/A ASPHALT: N/A CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL: Native Soil COMMENTS: Crew found concrete at the depth of 7 inches T/Concrete and 17 inches B/Concrete. |^HrPH405^H ^|~PH^04_H^H Pothole 404 is located approximately 3 feet NE from the curb of NW bound lane of Roosevelt Street. Pothole is located at the left side of driveway to 2906 Roosevelt Street. The photo was taken standing in front of pothole 405 looking north. A down hole view of concrete encasement housing ATT utility found at the depth of 27 inches T/E and 48 inches B/E A second concrete encasement housing electric utility was found at the depth of 35 inches T/E. Utilities run in NW/SE direction at the pothole location and was found within markout area. RECORD OF TEST HOLE DATA AIRX JOB NO; XI30126 TEST HOLE NO; 406 DATE DUG; 10-28-13 UTILITY TYPE Package of pipes Electric Storm Drain Electric SIZE & MATERIAL White & Gray PVC Concrete Encasement CCMLS UTILITY DEPTH 28.0"T/Pkg-37.0"B/Pkg N/A 59.0" T/P 2.0" PVC 13.0" T/P ENCASEMENT TOP N/A 37.5" T/E N/A N/A ENCASEMENT BOTTOM N/A 48.0" B/E N/A N/A UTILITY DIRECTION NE/SW NE/SW NE/SW NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 4.0" ASPHALT: 4.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No N/A Clay COMMENTS: Storm drain was to big to measure. Pothole 406 is located in the parking lane of NE bound lane of Grand Avenue. Pothole is located approximately 50 feet NE from the intersection mVn Roosevelt Street. The photo was taken standing in front of pothole 406 looking SW. A close up view of 2 inch PVC electric utility found in pothole 406 at the depth of 13 inches T/P. Utility runs in NW/SE direction at the pothole location. A CCMLS electric utility was found at the depth of 59 inches T/P and mns in NE/SW direction. A concrete encasement housing electric utility was found at the depth of 37.5 inches T/P and runs in NE/SW direction. A package of (white & gray) pipes was found at the depth of 28 inches T/Pkg and 37 inches B/Pkg and it runs in NE^SW direction. All utilities were found vKithin markout area. RECORD OF TEST HOLE DATA AIRX JOB NO; X130126 TEST HOLE NO; 407 DATE DUG; 10-28-13 UTILITY TYPE Electric SIZE & MATERIAL 2,0" Steel APPROXIMATE STATION 1 2 3 4 PAVEMENT THICKNESS: NORTHING COORDINATES UTILITY DEPTH 11,0" T/P EASTING COORDINATES ENCASEMENT TOP N/A GROUND ELEVATION N/A ASPHALT: N/A CONCRETE: N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW UTILITY ELEVATION BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; NO PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL: Native Soil COMMENTS: Pothole is located approximately 5 feet SE from the curb of NE bound lane of Grand Avenue, Pothole is located in front of entrance to 699 Grand Avenue. The photo was taken from NE bound lane of Grand Avenue looking south. A close up view of 2 inch steel electric utility found in pothole 407 at the depth of 11 inches T/P. Utility runs in NE/SW direction at the pothole location and it was found within markout area. RECORD OF TEST HOLE DATA AIRX JOB NO; X130126 TEST HOLE NO; 409 DATE DUG; 10-28-13 UTILITY SIZE & UTILITY ENCASEMENT ENCASEMENT UTILITY TYPE MATERIAL DEPTH TOP BOTTOM DIRECTION 1 Water Sen/ice 2.0" PVC 16.0" T/P N/A N/A NW/SE 2 Electric 2.0" PVC 32.0" T/P N/A N/A NW/SE 3 Cable 0.5" Black Cable 34.0" T/P N/A N/A NW/SE 4 Electric 4.0" PVC 47.5" T/P N/A N/A NW/SE ATT 4.0" PVC 49.0" T/P N/A N/A NW/SE APPROXIMATE NORTHING EASTING GROUND UTILITY STATION 1 COORDINATES COORDINATES ELEVATION ELEVATION 2 3 4 PAVEMENT THICKNESS: N/A ASPHALT: N/A CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA: Yes TRACER WIRE FOUND: No MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes PIPE COVER MATERIAL; OVERBURDEN MATERIAL: N/A Clay COMMENTS: Pothole 409 is located approximately 3 feet NE from the curb of NW bound Madison Street approximately 30 feet SE from Grand Avenue. The photo was taken standing in front of pothole 409 looking NE. A close up view of 2 inch PVC water utility found at the depth of 16 inches T/P. A 2 inch PVC electric utility was found at the depth of 32 inches T/P. A 0.5 cable was found at the depth of 34 inches. A 4 inch PVC electric utility was found at the depth of 47.5 inches T/P. A 4 inch PVC ATT utility was found at the depth of 49 inches T/P. All utilities mn in NW/SE direction at the pothole location and were found within markout area. 9 Phone: 760-480-2347 Fax; 760-739-8034 Cell: 760-419-2183 REPORT FOR City Of Carlsbad - Public Works Department 1635 Faraday Avenue Carlsbad, CA 92008 Attn: Sherri Howard PROJECT #X 140037 Utility Locating and Potholing Northwest Quadrant Storm Drain Improvement Program Grand Avenue Carlsbad, CA c TABLE OF CONTENTS 1. INTRODUCTION 2. PROJECT DESCRIPTION AND COMMENTS 3. PROJECT MAP 4. POTHOLE AREA MAPS 5. POTHOLE TABULATION 6. RECORD OF TEST HOLE DATA SHEETS PREPARED BY AIRX UTILITY SURVEYORS 2534 East El Norte Parkway Suite C Escondido, Ca. 92027 Tel. 760-480-2347 www.AIRXus.com DESCRIPTION OF POTHOLE PROCEDURES AIRX Utility Surveyors performs a flill range of specialized engineering services including Underground Utility Location and Vacuum Excavation (to verify depth and alignment of underground utilities). Underground Utility Location employs sophisticated electronic locating devices to trace the route of an underground utility; then the route is marked on the surface with marking paint in paved areas, or with 60 penny nails and feathers in unpaved areas. Vacuum excavation employs a vacuum truck in conjunction with high-pressure air or water to excavate material and expose an underground utility. A 10 to 12 inch diameter hole is first cored or chiseled through the pavement so that the vacuum hose and high pressure air or water hose can be inserted. Utilities found during potholing are located on the surface by placing two reference points (typically 36" apart) on either side of the pothole along the centerline (or edge) ofthe utility, using paving nails or 60 penny nails as appropriate. Depth measurements (to the nearest Vi inch) are taken midway between the two reference points. Utility alignment, depth, and other data is marked with pink paint (on pavement), or on wood lath (unpaved areas). SITE SPECIFIC DETAILS AIRX was contracted by Sherri Howard from City Of Carlsbad - Public Works Department of Carlsbad, Califomia to perform utility locating and potholing services at Grand Avenue in the City of Carlsbad, Califomia. A total of 15 potholes were excavated to establish conflicts and coimection points on a variety of utilities. The results of the data are contained in the attached spreadsheet and data sheets. In preparation of these excavations, AIRX marked out the dig locations and called in for USA. (Underground Service Alert). Existing traffic control plans and permits were reactivated and applied for by AIEOC. The traffic control equipment was set up by AIRX. All ofthe excavations and discovery went without any major incident except for potholes 516 and 517 which were canceled per Scott Cartwright. In addition water utility in pothole 504 was not found as it mns in N/S direction at the pothole 505 and doesn't mn through pothole 504. In pothole 513 water and sewer utilities were not found as the pothole crew reached big chunks of concrete at the depth of 91". Sewer utility marked out in pothole 513 was dipped in nearby manholes at the depth of 151 inches T/P and 149 inches T/P. The 12" water was potholed about 8 feet to the north and south with consistent depth. All changes and explanations from the original pothole plan are mentioned in the Pothole Tabulation spreadsheet and Record Of Test Hole Data sheets. All the results were annotated on the ground and in this report. It is AIRX's recommendation that all pothole locations and the active mark out should be surveyed to aid in the adjustment utilities on the final plan and profile. At each pothole location, the utility alignment was marked with pink paint, as well as 60 penny nails or feathers. AIRX used potable water acquired offsite for excavation and all water and material vacuumed was disposed of offsite. No water was allowed to flow into storm drains or natural drainages. The potholes were covered with clean backfill material and compacted to 95% density in 3" lifl:s. The pavement was patched with an equal thickness of replacement asphalt. In addition street pavers were used to finish the surface of pothole 504. All field work was performed between March 17* and March 31'* 2014. o o o • 3 g m S S 9, ~ S S s 1 o > to Ills g; ra o : ? 2 2 . O ra.S 3 .2 O o ii o u ca c UJ S -o • 2 I o •Z E 5 SI a. 1= ^ 3 (1) .2 CO fll c ffi 5 w 0) Q. O CO ra E z 4> — N ."S « I 5* « C T3 CO OJ o ra ffl < , o -g -S f 2 S a. O w S 2- o ra a T3 !^ I ^ ~ ,12 c III 5 Z < z 3 "S; f 2 ffi Q: o ,s mas ,» § I CO C p- °ll ? E s a: O .£ 03 in z 0. o > Q- E 8 cB UJ 2! « S £ o *- ,J2 •a 1 ffi 5 s _g to 2I c _ E B 7^ •5 £ ra £ • 1 = < o Q. (3 ,S 5 z z o o z cn ±= § — i£ CO S <U < ra (u ol O 1 E 8 „ 1 2 S 1 5 (0 (A <U — ZI f 2 ffi oL O ,£ < Z z 5 z 0. o < c Z 01.S S S r 8.« ra E c •a = UJ ffl (0 S z ' » 0] (0 £ 5 S g ^ _0 (0 « <» — 3 IO C rf g § ,9 o 2 ffi nl O ,£ CO B z z z < z £ ffl *. 12 < z 2 o o ~ ra D E O ,9 ra ffl S 9> 5 2- 5,§ < z ffi f ra ffl 8 2 53 s| 0) CO c to II 9 2 CO U] It S in v.* O O II - "° != O S 2 CD !S|| CO . o ^ Ll. a. f £ E I , S 'S . S •o c E I i I S 3 B P 5 S K 3 " o ^ ffl ffl £ 2 m ra ffl ffl Z E S 1 s , • I .o • ^ 3 CO a ra < Z 3 z o n £ E RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 501 DATE DUG; 03-18-14 UTILITY TYPE Electric SIZE & MATERIAL 4.0" PVC UTILITY DEPTH 46.0" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No N/A Clay COMMENTS: o Pothole 501 is located In the NE bound lane of Grand Avenue Pothole is located approximately 135 feet SW from the intersection with Jefferson Street. This photo was taken standing in front of pothole 501 looking West. A close up view of 4 inch PVC electric utility found in pothole 501 at the depth of 46.5 inches T/P, Utility runs in NE/SW direction at the pothole location and was found Directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 502 DATE DUG; 03-17-14 UTILITY TYPE Water ATT SIZE & MATERIAL 12.0" PVC 2.0" PVC UTILITY DEPTH 52,0" T/P 33.0" T/P ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION NE/SW NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: N/A BASE COUFiSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN: COMMENTS: Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL; OVERBURDEN MATERIAL; No N/A Hard Clay Pothole 502 is located in the NE bound lane of Grand Avenue af the intersection with Madison Street. This photo was taken standing in front of pothole 502 looking NW. A down hole view of 12 inch PVC water utility found in pothole 502 at the depth of 52 inches T/P. Utility runs in NE/SW direction at the pothole location and was found directly on markout. A 2 inch PVC ATT utility was found at the depth of 33 inches T/P. Utility runs in NW/SE direction at the pothole location and was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 503 DATE DUG; 03-18-14 UTILITY TYPE Water SIZE & MATERIAL 12,0" CCMLS Water 12.0" ACP UTILITY DEPTH 36,0"T/P 55.5" TIP ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION NE/SW NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL: OVERBURDEN MATERIAL; No N/A COMMENTS: Pothole 503 is located in the NE bound lane of Grand Avenue, Pothole is located at the intersection with Madison Street, This photo was taken standing in front of pothole 503 looking NW, o A down hole view of 12 inch CCMLS water utility found in pothole 503 at the depth of 36 inches TIP. Utility runs in NE/SW direction at the pothole location and was found directly on markout, A 12 inch ACP water utility was found at the depth of 55.5 inches T/P. Utility runs in NW/SE direction at the pothole location and was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO: 504 DATE DUG; 03-19-14 UTILITY TYPE Electric Water SIZE & MATERIAL (2) 4.0" PVC Not Found UTILITY DEPTH 36.5" T/P N/A ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION NE/SW N/A APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: Bricks CONCRETE: 5.0" BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No N/A Clay COMMENTS: Water utility not found. Water line mns in N/S direction in pothole 505 and doesn't mn thm pothole 504. Pothole 504 is located at the SE corner ofthe Grand Avenue and Madison Street intersection. This photo was taken standing in front of pothole 504 and 505 looking NW. A close up view of (2) 4 inch PVC electric utility found In pothole 504 at the depth of 36.5 inches TIP. Utility runs in NE/SW direction at the pothole location and was found within markout area. Water utility not found in pothole 504, Water line mns in N/S direction in pothole 505 and doesn't run thru pothole 504. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 505 DATE DUG; 03-17-14 UTILITY TYPE Storm Drain Water SIZE & MATERIAL 24.0" CCMLS 12.0" PVC UTILITY DEPTH 20.0" TIP 42.0" TIP ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION NBSW N/S APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Hard Clay COMMENTS: Water line was marked out running in NW/SE direction, actual line mns in N/S direction at the pothole location. o Pothole 505 is located at the east corner of Grand Avenue and Madison Street intersection. This photo was taken standing in front of pothole 505 looking NW. A close up view of 24 Inch CCMLS storm drain utility found in pothole 505 at the depth of 20 inches TIP. Utility runs in NE/SW direction at the pothole location and was found directly on mari^out. A 12 Inch PVC water utility was found at the depth of 42 inches TIP. Utility runs in N/S direction at the pothole location, Markout shows water line mnning in NW/SE direction. Utility was found within martcout area. RECORD OF TEST HOLE DATA AIRX JOB NO: X140037 TEST HOLE NO; 506 DATE DUG; 03-18-14 UTILITY TYPE ATT-D SIZE & MATERIAL 2.0" TIP Water 12.0" ACP UTILITY DEPTH 31.5" T/P 43.0" TIP ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION W/E NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No N/A Clay COMMENTS: Pothole 506 is located at the Grand Avenue and Madison Street intersection. This photo was taken standing in front of pothole 506 looking NW. A down hole view of 2 inch PVC ATT-D utility found in pothole 506 at the depth of 31,5 inches TIP. Utility runs in W/E direction at the pothole location and was found directly on mari<out. A 12 inch ACP water utility was found at the depth of 43 inches TIP. Utility runs in NW/SE direction at the pothole location and was found 24 inches SW off the markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO: 507 DATE DUG; 03-18-14 UTILITY TYPE SIZE & MATERIAL UTILITY DEPTH ENCASEMENT TOP ENCASEMENT BOTTOM UTILITY DIRECTION 1 Sewer 8.0" VCP 108,5" T/P N/A N/A NW/SE 2 Water 12.0" CCMLS 42.5" TIP N/A N/A NE/SW 3 Water 10.0" ACP 56.0" TIP N/A N/A NE/SW 4 APPROXIMATE STATION 1 NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION 2 3 4 PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA: Yes TRACER WIRE FOUND; Yes MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes PIPE COVER MATERIAL; OVERBURDEN MATERIAL; N/A Clay COMMENTS: Top Right; A close up view of 12 inch CCMLS water utility found at the depth of 42.5 Inches TIP. Utility runs In NE/SW direction at the pothole location and was found within markout area, A 10 inch ACP water utility was found at the depth of 56 inches TIP. Utility runs in NE/SW direction at the pothole location. Above; Pothole 507 is located at the Grand Avenue and Madison Street intersection. This photo was taken standing in front of pothole 507 looking NW. Bottom Right; A down hole view of 8 inch VCP sewer utility found at the depth of 108.5 inches TIP. Utility mns in NW/SE direction at the pothole location and was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO: 508 DATE DUG; 03-17-14 UTILITY TYPE Water SIZE & MATERIAL 12.0" ACP UTILITY DEPTH 43.0" TIP ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND: No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Native Soil Pothole 508 is located in NE bound lane of Grand Avenue approximately 35 feet SW from the intersection with Madison Street. This photo was taken standing in front of pothole 508 looking NW. A down hole view of 12 inch ACP water utility found in pothole 508 at the depth of 43 inches TIP. Utility mns in NE/SW direction at the pothole location and was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 509 DATE DUG; 03-17-14 UTILITY TYPE Sewer Lateral SIZE & MATERIAL 4,0" VCP UTILITY DEPTH 84.0" TIP ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 6.0" ASPHALT: 6.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; No PIPE COVER MATERIAL; N/A OVERBURDEN MATERIAL; Hard Clay o Pothole 509 is located in the NE bound lane of Grand Avenue approximately 120 feet SW from the intersection with Madison Street. This photo was taken standing in front of pothole 509 looking NW. A down hole view of 4 inch VCP sewer lateral utility found in pothole 509 at the depth of 84 inches TIP. Utility runs in NW/SE direction at the pothole location and was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 510 DATE DUG; 03-19-14 UTILITY TYPE Sewer SIZE & MATERIAL 12.0" CCMLS UTILITY DEPTH 121,5" T/P ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 5.0" ASPHALT: 5.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND: PIPE COVER MATERIAL; OVERBURDEN MATERIAL: No N/A Clay 9 The pothole crew did not find the sewer lateral connection at this location and depth. Sewer lateral was already found in pothole 509. Pothole 510 is located in the NE bound lane of Grand Avenue approximately 120 feet SW from the intersection with Madison Street. This photo was taken standing in front of pothole 510 looking SW. A close up view of 12 inch CCMLS sewer utility found in pothole 510 at the depth of 121.5 inches TIP. Utility runs in NE/SW direction at the pothole location and found within mari<out area. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 511 DATE DUG; 03-19-14 UTILITY TYPE Water SIZE & MATERIAL 12,0" ACP UTILITY DEPTH 52,0" TIP ENCASEMENT TOP N/A ENCASEMENT BOTTOM N/A UTILITY DIRECTION NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 7.0" ASPHALT: 7.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL; YM N/A Clay Pothole 511 is located in the NE bound lane of Grand Avenue pothole is located at the NE side of the intersection with State Street. This photo was taken standing in front of pothole 511 looking NW. A close up view of 12 inch ACP water utility found in pothole 511 at the depth of 52 inches TIP. Utility runs in NE/SW direction at the pothole location and was found directly on markout. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 512 DATE DUG; 03-20-14 UTILITY TYPE Water Water SIZE & MATERIAL 12,0" ACP 12.0" ACP UTILITY DEPTH 55,0" TIP 56,0" TIP ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION NW/SE NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 15.0" ASPHALT: N/A CONCRETE: 15.0" BASE COUFiSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: Yas N/A Clay Pothole 512 is located at the Grand Avenue and State Street intersection. This photo was taken standing in front of pothole 512 and 513 looking NE. A down hole view of 12 inch ACP water utility found in pothole 512 at the depth of 55 inches TIP. Utility runs in NW/SE direction at the pothole location and was found directly on mari^out. A 12 inch ACP water utility was found at the depth of 56 inches TIP. Utility runs in NE/SW direction at the pothole location and was found within markout area. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 513 DATE DUG; 03-20-14 UTILITY TYPE Sewer Water SIZE & MATERIAL Not Found Not Found UTILITY DEPTH N/A N/A ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION N/A N/A APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 15.0" ASPHALT: N/A CONCRETE: 15.0" BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: YM N/A Clay COMMENTS: The pothole crew dug to 91 inches deep and couldn't get any deeper, big chunks of concrete at this depth. No sewer or water utility found. Sewer utility was dipped in the manholes at the depth of 151 inches TIP and 149 inches TIP. o Pothole 513 is located at the Grand Avenue and State Street intersection. This photo was taken standing in front of pothole 512 and 513 looking NE. Pothole 513 is 91 inches deep. Big chunks of concrete stop crew from going any deeper. No sewer utility and water utility found. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 514 DATE DUG; 03-21-14 UTILITY TYPE Water SIZE & MATERIAL 12.0" ACP Sewer ACP UTILITY DEPTH 54.0" TIP 122,5" T/P ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION NW/SE NE/SW APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 16.0" ASPHALT: N/A CONCRETE: 16.0" BASE COURSE: N/A UTILITY MARKED BY USA; MARKOUT LOCATION CORRECT: UTILITY SHOWN ON PLAN; COMMENTS: Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: Yes N/A Clay 9 Sewer line is too deep to measure. Pothole 514 is located at the Grand Avenue and State Street intersection. This photo was taken standing in front of pothole 514. A down hole view of 12 inch ACP water utility found in pothole 514 at the depth of 54 inches TIP. Utility runs in NW/SE direction at the pothole location and was found within markout area. A ACP sewer utility was found at the depth of 122.5 TIP. Utility runs in NE/SW direction at the pothole location and was found within markout area. RECORD OF TEST HOLE DATA AIRX JOB NO; X140037 TEST HOLE NO; 515 DATE DUG; 03-19-14 UTILITY TYPE Gas Street Light SIZE & MATERIAL 3.0" Steel 2.0" Steel UTILITY DEPTH 33.5" TIP 29.5" TIP ENCASEMENT TOP N/A N/A ENCASEMENT BOTTOM N/A N/A UTILITY DIRECTION NE/SW NW/SE APPROXIMATE STATION NORTHING COORDINATES EASTING COORDINATES GROUND ELEVATION UTILITY ELEVATION PAVEMENT THICKNESS: 7.0" ASPHALT: 7.0" CONCRETE: N/A BASE COURSE: N/A UTILITY MARKED BY USA: MARKOUT LOCATION CORRECT; UTILITY SHOWN ON PLAN; Yes Yes Yes TRACER WIRE FOUND; PIPE COVER MATERIAL; OVERBURDEN MATERIAL: Yes N/A Clay COMMENTS: Pothole 515 is located in the SW bound lane of Grand Avenue approximately 100 feet SW from the intersection with State Street. This photo was taken standing in front of pothole 515 looking NE. A close up view of 3 inch steel gas utility found in pothole 515 at the depth of 33.5 inches TIP. Utility runs in NE/SW direction at the pothole location and was found directly on markout. A 2 inch steel street light utility was found at the depth of 29.5 inches TIP. Utility runs in NW/SE direction at the pothole location and was found directly on markout. APPENDIX E - STORM DRAIN INLET STENCIL 3 o 2 D Q $ 5: I 3 o 3 === Ol § " CD 2 '-^ IVJ ffj •Nl 2 r- ^ 00 to 5 Oo o o _ Co —A. o o i2> CO o 03 r< m § c: o 2 O P o o 3| 3 Sal ?5 9 == 3- §^ CJl § S I to S r= cn •3 in CD r— >• Co p i. 00 o ?! Co 2 Co o OD r< s Oo ^ o :^ CO o 00 CO cd • o D 2 o o § i 3 o APPENDIX F STANDARD TRAFFIC CONTROL PLAN i i i i 8 I 3 i i: ,„ s I i 18' P Mi 3 ig il' h 3h '58 5 -•if m <il><i>^e 11 p o o :c >D ;o P S > i I 1 llli APPENDIX G VILLAGE EVENTS State Street Farmers' Market Carlsbad Village Association Every Wednesday (State St. btw Grand and CVD closed from l-8pm) Carlsbad Village Street Faire Carlsbad Chamber of Commerce First Sunday of May and first Sunday of November Art in the Village Carlsbad Village Association Second Sunday in August Carlsbad 5000 Competitor Magazine March 29, 2015 O APPENDIX H STANDARD DRAWINGS c See M-1 for manhole frame and cover Transition to normal curb height in 10' on both sides unless otherwise noted Curb line 4 radius See D-12 for continuous galvanized steel face angle and protection bar- 1IJ@6- Wing where occurs "one or both sides 12" B Length shown on plans PLAN L= length shown on plans Slope to match curb profile or as shown on plons -Edge of gutter *See Note 8 l'-9" r-6" SECTION B-B Slope gutter 3" or match existing roadway surface 1-3" lO'unless shown -otherwise 6" min iJ U— (typical both sides) 30 D iLap (typ) 1 Y Optional construction joint 6" min above invert 4-J!!4 around pipe Slope floor 12:1 towards outlet Street Y is determined by pipe size-4' min, 8' max Rounded pipe ends see D-61 r-Elev shown on plans .^2-1 rOptional construction joint 6" min above invert SECTION C-C NOTES I.See D-11A, D-1 IB, & D-12 for additional notes and details. 2. Types are designated on plans as follows: A (no wing), A-1 (one wing), or A-2 (two wings). 3. Exposed edges of concrete shall be rounded with a radius of 1/2". 4.Steps shall be installed when V exceeds 4'. See D-11A for details. 5. Concrete gutter to match adjacent gutters. 6. An expansion joint shall be placed at the ends of the inlet where the curb is to adjoin. 7. Provide 1/4" tooled groove in top slab in line with back of adjacent curb. 8. Surface of top slab to match sidewalk finish and slope. , 9. Maintain 1-1/2" clear spacing between reinforcing and concrete surface unless otherwise noted. 10. If required by local agency, extend top slab steel reinforcement 12" into adjacent sidewalk. 11. Elevations shall be shown on plans where indicated by "O symbol. SECTION A-A LEGEND ON PLANS WI Revision By Approved Date ORIGINAL Kercheval 12/75 Add Metric T, Stanton 03/03 Reformatted T. Stanton 04/06 Edited T, Stonton 02/09 Edited S.S, T, Regello 03/11 SAN DIEGO REGIONAL STANDARD DRAWING CURB INLET - TYPE A RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE cU<i Choirperson R,C,E, 19246 Dote DRAWING NUMBER D-01 — T |4 n around opening Transition to normal curb height in 10' on both sides unless otherwise noted See D-12 for continuous galvanized steel face angle and protection bar- •See Note 7 4"radius Curb line #4 @ 12" -6" Edge of gutter SECTION B-B 6"min ~ (typical both sides) 30 D Lap (typ) PLAN Length shown on plans Slope to match curb profile or as shown on plans CLR -7-1/2" 4-#4 around pipe "Optional construction joint ). 6' min above invert -Slope floor 12:1 towards outlet r= 30 D Lap (typ) Y is determined by pipe size-4' min, 8' max SECTION C-C -Rounded pipe ends I see D-61 ^' shown -Curb line 10 unless otherwise I—shown -See SDARSD D-11A & D-11B for horizontal & flooring reinforcement (See Note 11) SECTION A-A - Optional construction joint 6" min above invert -30 D Lap (typ) NOTES 1. See D-11 A, D-1 IB & D-12 for additional notes and details. 2. Types are designated on plans as follows: B (no wing), B-1 (one wing) or B-2 (two wings). 3. Maintain 1-1/2" clear spacing between reinforcing and concrete surface unless otherwise noted. 4. Steps shall be installed when V exceeds 4'. See D-11 A for details. 5. Concrete gutter to match adjacent gutters. 6. An expansion joint shall be placed at the ends of the inlet where the curb is to adjoin. 7. Provide 1/4" tooled groove in top slab in line with back of adjacent curb. 8. Surface of top slab to match sidewalk finish and slope. 9. If required by local agency, extend top slab steel reinforcement 12" into adjacent sidewalk. 10. Elevations shall be shown on plans where indicated by "O" symbol. 11. If required by local agency, enlarge curb inlet top to width of adjacent sidewalk (X -I- T not to exceed 5'-6 ) by length of inlet including wing(s). Reinforcing steel shall be extended across enlarged top to clear distances shown. LEGEND ON PLANS Revision By Approved Date ORIGINAL Kercheval 12/75 Add Metric T. Stonton 03/03 Reformatted T. Stanton 04/06 Edited T. Stanton 02/09 Edited S.S. T. Regeilo 03/11 SAN DIEGO REGIONAL STANDARD DRAWING CURB INLET - TYPE B RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE 7/'Z6/'a.0U Chairperson R.C.E, 19246 Dote DRAWING NUMBER D-02 #4 bars placed diagonally PLAN TYPE PIPE DIAMETER (Dl) X Y Z B5 up to 51" 5' 4' 5' B6 54" to 60" 6' 4' 6' B7 63" to 69" T 4' 7' B8 72" to 81" 8* 4' 8' B9 84" to 90" 9' 4' 9' -See M-3 for manhole frame and cover NOTES 1. See D-11A & D-1 IB for additional notes and details. 2. All joints shall be set in Class C mortar. 3. All precast components shall be reinforced with 1/4" diameter steel wound spirally on 4" centers. 4. Maintain 1-1/2" clear spacing between reinforcing and concrete surface. 5. Concrete base shall be 560-C-3250. 6. Exposed edges of concrete shall be rounded with a 1/2" radius. 7. Manhole cover to be marked "Storm Drain". 8. Modifications to 'Y" dimension required if pipe (D2) exceeds 39". 9. If constructed adjacent to sidewalk, top of manhole to match sidewalk slope. See D step detail Bend down 15" (typ) Rounded pipe ends see D-61 Elev shown on plans—- .|30 D Lap (typ) X -4-#4 around pipe -Slope floor 12:1 towards outlet SECTION A-A LEGEND ON PLANS = 0 = Revision By Approved Date ORIGINAL Kercheval 12/75 Add Metric T. Stanton 03/03 Reformatted T. Stanton 04/06 Edited T. Stanton 02/09 Edited S.S. T, Regello 03/11 SAN DIEGO REGIONAL STANDARD DRAWING STORM DRAIN CLEANOUT - TYPE B RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE Chairperson R.CE, 19246 Date DRAWING NUMBER D-10 /Vertical reinforcing /] 18" max (typ) — 1-1/2" CLR (typ) -A ,-See table on D-1 IB for horizontal and floor reinforcement 2" (typ) TYPICAL BOX SECTION 4"- A 10" T Approved steel reinforced- polypropylene step STEP DETAIL NOTES 1. Concrete shall be 560-C-3250 unless otherwise noted. 2. Reinforcing steel shall comply with this drawing (D-11 A ond D-1 IB) unless otherwise specified. 3. Reinforcing steel shall be intermediate grade deformed bars conforming to latest ASTM specifications. 4. Bends shall be in accordance with latest ACI code. 5. Minimum splice length for reinforcing shall be 30 diameters. 6. Floor shall have a wood trowel finish and, except where used as junction boxes, shall have a minimum slope of 1:12 toward the outlet. 7. Depth V is measured from the top of the structure to the flowline of the box. 8. Wall thickness and reinforcing steel required may be decreased in accordance with table on D-1 IB. 9. Wall thickness shall be stepped on the outside of the box. 10. When the structure depth V exceeds 4', steps shall be cast into the wall at 15" intervals from 15" above floor to within 12" of top of structure. Where possible place steps in wall without pipe opening, otherwise over opening of smallest diameter. 11. Alternate step may be an approved steel reinforced polypropylene step. 12. Upon approval of the Agency, the use of precast storm structures is acceptable as an alternate to cast-in-place. Precast units shall conform to ASTM standards and be manufactured in a permanent facility designed for that purpose. Revision By Approved Dote SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE ORIGINAL Kercheval 12/75 SAN DIEGO REGIONAL STANDARD DRAWING Add Metric T. Stanton 03/03 INLETS AND CLEANOUTS Reformatted T. Stanton 04/06 INLETS AND CLEANOUTS Chairperson R.CE, 19246 Date Edited T. Stanton 02/09 NOTES AND DETAILS DRAWING n 11A NUMBER ^'' Edited S.S T, Regello 03/11 NOTES AND DETAILS DRAWING n 11A NUMBER ^'' BOX SECTION REINFORCEMENT (HORIZONTAL AND FLOOR) MAXIMUM SPAN X or Y DEPTH V THICKNESS T HORIZONTAL AND FLOOR REINFORCEMENT SIZE AND SPACING 3' to 4' 4' 6" #4 ® 18" 4'-r to 7' 4' 6" #4 ® 12" 7'-r to 8' 4' 6" #4 ® 8" 3' to 4' 4'-1"to 8' 6" #4 @ 18" 4'-r to 5' 4'-1"to 8' 6" #4 ® 12" 5'-r to 6" 4'-1"to 8' 6" #4 @ 8" 6'-1" to 8' 4'-1"to 8' 6" #4 ® 6" 3' to 4' 8'-1" to 12' 6" #4 ® 15" 4"-r to 5' 8'-1" to 12' 8" #4 @ 12" 5"-r to 6" 8'-1" to 12' 8" #4 @ 8" 6'-1" to 8' 8'-1" to 12' 8" #4 @ 6" 3' to 4' 12-1" to 16' 8" #4 @ 12" 4'-r to 5' 12-1" to 16' 8" #4 9 12" 5*-r to 6' 12-1" to 16' 8" #4 @ 8" 6'-1" to 7' 12-1" to 16' 8" #4 ® 6" 7'-1" to 8' 12-1" to 16' 8" #5 @ 8" 3' to 4" le'-l" to 20' 8" #4 9 12" 4'-1" to 5' le'-l" to 20' 10" #4 @ 12" 5'-r to 6' le'-l" to 20' 10" #4 @ 8" 6'-1" to 7' le'-l" to 20' 10" #4 ® 6" 7'-r to 8' le'-l" to 20' 10" #5 @ 8" 3' to 4' 20'-1" to 24' 8" #4 ® 12" 4'-r to 5" 20'-1" to 24' 10" #4 @ 12" 5'-r to 6' 20'-1" to 24' 10" #4 @ 8" 6'-l" to 7' 20'-1" to 24' 10" #4 @ 6" 7'-r to 8' 20'-1" to 24' 12" #5 @ 8" Revision By Approved Date SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE Choirperson R.CE. 19246 Date ORIGINAL Kercheval 12/75 SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE Choirperson R.CE. 19246 Date Add Metric T, Stanton 03/03 INLETS AND CLEANOUTS NOTES AND DETAILS RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE Choirperson R.CE. 19246 Date Reformatted T, Stanton 04/06 INLETS AND CLEANOUTS NOTES AND DETAILS RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE Choirperson R.CE. 19246 Date Edited S.S. T, Regello 03/11 INLETS AND CLEANOUTS NOTES AND DETAILS DRAWING n IID NUMBER L>-11b INLETS AND CLEANOUTS NOTES AND DETAILS DRAWING n IID NUMBER L>-11b 3/4" crushed rock SECTION NOTES 1. See G-24A and G-24B or G-25 for resurfacing details on improved streets. 2. (*) indicates minimum relative compaction. 3. Top 12" of trench backfill in street section shall be 95% relative compaction unless specified otherwise. Revision By Approved Dote SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE ORIGINAL Parkinson 2/95 SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE Add Metric T. Stanton 03/03 PIPE BEDDING AND TRENCH BACKFILL FOR STORM DRAINS RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE Reformatted T. Stanton 04/06 PIPE BEDDING AND TRENCH BACKFILL FOR STORM DRAINS ^~y^ 1 Chairperson R.CE. 19246 Dote Edited S.S. T, Regello 03/11 PIPE BEDDING AND TRENCH BACKFILL FOR STORM DRAINS DRAWING n ftn NUMBER "-^^ PIPE BEDDING AND TRENCH BACKFILL FOR STORM DRAINS DRAWING n ftn NUMBER "-^^ 1/2" R TYPE W *AREA G 24" 1.34 SQ. FT. H 30" 1.60 SQ FT. * 6" CURB FACE NOTES: 1. CONCRETE SHALL BE 520-C-2500. 2. SEE STANDARD DRAWINGS G-9 AND G-10 FOR JOINT DETAILS. 3. SLOPE TOP OF CURB 2% MAX TOWARD GUHER. LEGEND ON PLANS REVISION BY APPROVED DATE SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE ORIGINAL KERCHEVAL 12/75 SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE ADD METRIC T, STANTON 03/03 CURB AND GUTTER - COMBINED RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE ^EFORMAnED T. STANTON 04/06 CURB AND GUTTER - COMBINED CHAIRPERSON R.CE. 19246 DATE UPDATED MR MR/CV 11/11 CURB AND GUTTER - COMBINED DRAWING p 0 NUMBER ^"^ CURB AND GUTTER - COMBINED DRAWING p 0 NUMBER ^"^ NE _j m on ZD 6" O 6" 2" WEAKENED PLANE JOINT 1/2" R -z. o i TYPE W •AREA G 24" 1,34 SQ. FT. H 30" 1,60 SQ FT, * 6" CURB FACE NOTES: 1. CONCRETE SHALL BE 520-C-2500, 2 SEE STANDARD DRAWINGS G-9 AND G-10 FOR JOINT DETAILS. 3 SLOPE TOP OF CURB 2% MAX TOWARD GUHER. LEGEND ON PLANS 1 REVISION BY APPROVED DATE 1 ORIGINAL KERCHEVAL 12/75 |ADD METRIC T, STANTON 03/03 IREFORMAHED T, STANTON 04/06 1 UPDATED MR MR/CV 11/11 SAN DIEGO REGIONAL STANDARD DRAWING CURB AND GUTTER - COMBINED RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE ChTAIRPERSON R.CE, 19246 DATE DRAWING NUMBER G-2 r I— / VARIES WIDTH AS SHOWN ON PLANS 1/2-1 -4" ^2% MAX CROSS-SLOPE 1 1/2" R^ ^^^^^^ ^-^^^^ I 2" WEAKENED 1 PU\NE JOINT - NON-CONTIGUOUS WIDTH AS SHOWN ON PLANS / 1/2" R CONTIGUOUS NOTES: 1. CONCRETE SHALL BE 520-C-2500. 2. SEE STANDARD DRAWINGS G-9 AND G-10 FOR JOINT DETAILS, LEGEND ON PLANS REVISION BY APPROVED DATE SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO j REGIONAL STANDARDS COMMITTEE ORIGINAL KERCHEVAL 12/75 SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO j REGIONAL STANDARDS COMMITTEE ADD METRIC T. STANTON 03/03 SIDEWALK - TYPICAL SECTIONS RECOMMENDED BY THE SAN DIEGO j REGIONAL STANDARDS COMMITTEE ^EFORMAHED T. STANTON 04/06 SIDEWALK - TYPICAL SECTIONS CH'AIRPERSON R,C,E. 19246 DATE UPDATED MR MR/CV 11/11 SIDEWALK - TYPICAL SECTIONS DRAWING r 7 NUMBER \ SIDEWALK - TYPICAL SECTIONS DRAWING r 7 NUMBER \ -MID POINT OF CURB RETURN 45 TYP. •P.C.R. NOTES: 1, EXPANSION JOINTS AT CURB RETURNS, ADJACENT TO STRUCTURES AND AT 45' INTERVALS. (SEE STANDARD DRAWING G-10). 2, WEAKENED PLANE JOINTS AT MID POINT OF CURB RETURN, WHEN REQUIED, AND AT 15' INTERVALS FROM P.C.R. (SEE STANDARD DRAWING G-10). 3, 1/4" GROOVES WITH 1/4" RADIUS EDGES AT 5' INTERVALS, REVISION BY APPROVED DATE SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO 1 REGIONAL STANDARDS COMMITTEE 1 ^ "^^f^ -"^''^'"'^ ORIGINAL KERCHEVAL 12/75 SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO 1 REGIONAL STANDARDS COMMITTEE 1 ^ "^^f^ -"^''^'"'^ ADD METRIC T, STANTON 03/03 SIDEWALK JOINT LOCATIONS RECOMMENDED BY THE SAN DIEGO 1 REGIONAL STANDARDS COMMITTEE 1 ^ "^^f^ -"^''^'"'^ REFORMATTED T, STANTON 04/06 SIDEWALK JOINT LOCATIONS CH'AIRPERSON R,C,E, 19246 DATE 1 UPDATED MR MR/CV 11/11 SIDEWALK JOINT LOCATIONS DRAWING p Q NUMBER ^"^ 1 SIDEWALK JOINT LOCATIONS DRAWING p Q NUMBER ^"^ 1 EXPANSION JOINT FILLER MATERIAL /8" R 1/8" R /2" (PAVEMENT) 1/4" MIN - 1/2" MAX (SIDEWALK) EXPANSION JOINT 1/2" (#4) X 24" SMOOTH, GREASED OR OILED BAR, 30" ON CENTER CONTACT JOINT 1/8" R .L . . . .L' . . . ., I.. 1—1/4" • -' - 1^ '• • 1/8"-/- PREFORMED JOINT •A C^l ^1/4" » . , . »•. . . • k. . . . k >• C^l ^1/4" » . , . »•. . . • k. . . . k t> • ^1/4" » . , . »•. . . • k. . . . k WEAKENED PLANE JOINT CURB AND SIDEWALK 1-1/2" WEAKENED PLANE JOINT GUTTER AND CONCRETE PAVEMENT r-1/8" -5/8" KEYED JOINT REVISION nPiniNAi BY APPROVED PARKINSON DATE 02/95 SAN DIEGO REGIONAL STANDARD DRAWING RECOMMENDED BY THE SAN DIEGO REGIONAL STANDARDS COMMITTEE AxJi'^TlI^J^^^ ADD METRIC T. STANTON 03/03 CONCRETE JOINT DETAILS ^^im^ ^^^'^^"'^ REFORMATTED T, STANTON 04/06 CONCRETE JOINT DETAILS CHAIRPERSON R.C.E, 19246 DATE UPDATED CV MR/CV 11/11 CONCRETE JOINT DETAILS DRAWNG p in NUMBER ^"'^ CONCRETE JOINT DETAILS DRAWNG p in NUMBER ^"'^ VOLUME 3 - STANDARD DRAWINGS & SPECIFICATIONS CHAPTER 2 - CITY OF CARLSBAD MODIFICATIONS TO THE SAN DIEGO REGIONAL STANDARD DRAWINGS Note: The minimum allowable concrete mix design for all concrete placed within public right- of-way shall be 560-C-3250 as specified in the Standard Specifications for Public Works Construction. DWG. MODIFICATION D-2 Enlarge curb inlet top to width of sidev/alk (not to exceed 5'6") by length of inlet including wings. Existing reinforcing steel shall be extended across enlarged top to clear distances shown. D-20 Delete. D-27 Add: A maximum of three (3) combined outlets in lieu of Std. D-25. D-40 Add: "T" dimension shall be a minimum of three (3) times size of rip rap. D-70 Minimum bottom width shall be 6' to facilitate cleaning. D-71 Minimum bottom width shall be 6' to facilitate cleaning. D-75 Delete "Type-A" Add: 6" x 6" x #10 x #10 welded wire mesh, instead of stucco netting. E-1 Delete direct burial foundation. Add: The light standard shall be pre-stressed concrete round pole. E-2 Grounding per note 2. Attachment of the grounding wire to the anchor bolt shall be below the light standard base plate with an approved connection. G-3 Delete. G-5 Add: Note 4. Tack coat shall be applied between dike and existing asphalt concrete surface as specified in Section 302-5.4 SSPWC. G-6 Type B-1 not used. When specified, Type B-2 shall have a curb height of8", width of 6", with a 3:1 batter. When specifically approved by the City Engineer, Type B-3 shall have a curb height of 8", width of 6", a 3:1 batter with the hinge point eliminated. G-11 Add: Remove curb/gutter and sidewalk from score-mark to score-mark or from joint-to-joint or approved combination. Volume 3 - Chapter 2 1 of 2 CITY OF CARLSBAD MODIFICATIONS TO THE SAN DIEGO REGIONALSTANDARD DRAWINGS (CONTINUED) DWG. MODIFICATION G-12 Add: smooth trowel flow line (typical) 7-1/2" thick with a minimum of 6" of aggregate base per City of Carlsbad Standard GS-17. G-13 Add: smooth trowel flow line (typical), 7-1/2" thick, with a minimum 6" of aggregate base per City of Carlsbad Standard GS-17. G-14 Change: Residential Thickness = 5-1/2" Commercial/Multi-Family Residential Thickness = 7-1/2" G-15 Delete requirement 3 G-24 Replaced with Carlsbad Standard Drawing GS-25 G-25 "Type-C" only (delete "Type D") G-26 Change thickness from 5-1/2" to 7-1/2" and add minimum 4" Class II base under '^«-' curb/gutter (to 6" past back of curb). G-33 Delete G-34 "Type-C" only (delete "Type D") G-35 "Type-F" only (delete "Type E") M General: Agency shall be "City of Carlsbad" M-2 Add: To be used only with specific approval of the City Engineer. o Volume 3 - Chapter 2 2 of 2 A 1/8" EDGE TAPER PRECAST REINFORCED CONCRETE FINISHED GRADE ^^'fe'CLEAN CRUSHED ROCK ig-^^p. (1/2" MAX.) SECTION A-A t MOLDED LETTERS 1/8 DEEP (SEE NOTE 2) li t 4',|^ 4°>| O.C O.C O r SECTION B-B 3/8"0 DEF. ^STEEL BARS o < -A o TYPE COVER EDGE THICKNESS MIN. DEPTH BOX AND EXTENSION L* W* R 31/2 1 3/4" NO EXTENSION 15 3/8" 10 1/8" 1 1/8" 5 2" 22" 23 1/4" 13 3/4" 1 1/4" TOP DIMENSION COVER REINFORCING PLAN NOTES: 1) . USE STEEL COVER WHEN SUBJECTED TO TRAFFIC LOADS. 2) . PULL BOX COVER SHALL BE MARKED "STREET UGHTING" WHERE PULL BOX CONTAINS STREET UGHTING CONDUCTORS ONLY. "HIGH VOLTAGE" SHALL BE ADDED WHERE VOLTAGE IS ABOVE 600 VOLTS. 3) . THE L AND W DIMENSIONS OF THE COVER SEAT SHALL BE 1/8" GREATER THAN THE COVER DIMENSIONS. 4) . COMPACT EARTH UNDER AND AROUND PULL BOX. REV. APPROVED DATE CITY OF CARLSBAD PULL BOX FOR TRAFFIC SIGNAL AND STREET LIGHTING 6-04 CITY ENGINEER DATE SUPPLEMENTAL i'^o r\A STANDARD NO. OO-Z I SECTION ® 190-E-400 CONCRETE, MAXIMUM 8 SLUMP SLURRY BACKFILL TO SURFACE FOLLOW WITH 12" WIDE BY 1-1/2" DEEP GRIND AND RESURFACING. ALLOW MIN. 72 HOURS CURE BEFORE GRINDING. 0 D2-AR-4000 ASPHALT CONCRETE (3) ALL CONDUIT AND CABLE NJX 0 EXISTING A.C. PAVEMENT (5) EXISTING BASE MATERIAL (D MORTAR SAND COMPACTED TO 95% RELATIVE DENSITY. 0 UNDISTURBED SOIL (8) SYMMETRICAL ABOUT CENTERUNE OF TRENCH. (9) GRADE SS-1h EMULSIFIED ASPHALT APPUED AT 0.15 GALLON PER SQUARE YARD. (TQ) EXISTING ASPHALT PAVEMENT FINISHED GRADE, SMOOTHNESS & COMPACTION OF RESURFACING SHALL MEET THE REQUIREMENTS OF SEC 302-5.6.2 SSPWC EXCEPT THAT THE SMOOTHNESS SHALL BE DETERMINED OVER THE LENGTH & WIDTH OF PAVEMENT AREAS DISTURBED BY THE CONTRACTOR S/ PERMITEE S OPERATIONS. TOP OF CONDUIT AND CABLE * MINIMUM WIDTH 4" MAXIMUM WIDTH 6" (IT) RESPRAY GRADE SS-lh EMULSIFIED ASPHALT AT 0.15 GALLON PER SQUARE YARD 6" WIDE, CENTERED ON EDGE UNE OF GRIND AFTER PLACING A.C. & BEFORE SURFACE TREATMENT. (g) SURFACE TREATMENT TO MATCH EXISTING PAVEMENT (E.G. SEAL COAT, CHIP SEAL) Q) WHEN THE EDGE OF THE GRIND UNE IS WITHIN 12" OF EDGE OF PAVEMENT, ANY STRUCTURE, AN ADJACENT TRENCH PATCH OR ANY OfHER PAVING JOIN UNE THE 1-1/2" DEEP GRIND SHALL BE EXTENDED TO THE EXISTING STRUCTURE OR JOIN UNE. REV. APPROVED DATE CITY OF CARLSBAD /^/.^ ViJ iU' 12/11 NARROW TRENCH BACKFILL & ASPHALT CONCRETE RESURFACING /^Klf) A. yOr? rg^ ' CITY ENGINEER DATE NARROW TRENCH BACKFILL & ASPHALT CONCRETE RESURFACING SUPPLEMENTAL PQ 0/| STANDARD NO. OO-^H NARROW TRENCH BACKFILL & ASPHALT CONCRETE RESURFACING SUPPLEMENTAL PQ 0/| STANDARD NO. OO-^H V -ASPHALT CONCRETE FINISH COURSE SEE GS-28 ^ UMIT OF 2" GRIND (TYP.) EXISTING AC AND BASE ASPHALT CONCRETE BASE COURSE, SEE GS-28 AGGREGATE BASE PIPE BEDDING AND BACKFILL PER PROJECT PLANS, SPECIFICATIONS, AND CITY STANDARDS. NOTES: 1. THE DETAIL SHOWN ABOVE APPUES TO TRENCH WIDTHS FROM 26 INCHES TO 48 INCHES. 2. EXISTING A.C. SHALL BE CUT AND REMOVED IN SUCH A MANNER SO AS NOT TO TEAR, BULGE OR DISPLACE ADJACENT PAVEMENT. EDGES SHALL BE CLEAN AND VERTICAL. ALL CUTS SHALL BE PARALLEL OR PERPENDICULAR TO STREET CENTERUNE, WHEN PRACTICAL 3. BASE MATERIAL SHALL BE REPLACED TO DEPTH OF EXISTING BASE. A.C. MAY BE SUBSTITUTED FOR BASE MATERIAL AT THE CITY ENGINEER'S DISCRETION. 4. WHEN THE EDGE OF THE GRIND AREA IS WITHIN 24 INCHES OF EDGE OF PAVEMENT, ANY STRUCTURE, AN ADJACENT TRENCH PATCH, OR OTHER PAVING JOIN UNE, THE GRIND AREA SHALL BE EXTENDED TO THE EXISTING STRUCTURE OR JOIN UNE. 5. WHEN THE EDGE OF THE GRIND UES WITHIN A WHEEL PATH, THE GRIND AREA SHALL BE EXTENDED TO THE NEAREST LANE UNE OR EDGE OF PAVEMENI REV. APPROVED DATE CITY OF CARLSBAD KOLAVAJT jcfti***. Iv 9 /i n TRENCH RESURFACING ASPHALT CONCRETE PAVEMENT FOR TRENCH WIDTHS FROM 26" TO 48" p.oiA«v^-r- 1 • ^iovvvv^ iv. Z / 1U 1 CITY ENGII^ER OATE TRENCH RESURFACING ASPHALT CONCRETE PAVEMENT FOR TRENCH WIDTHS FROM 26" TO 48" SUPPLEMENTAL PQ OO STANDARD NO. OO-ZD TRENCH RESURFACING ASPHALT CONCRETE PAVEMENT FOR TRENCH WIDTHS FROM 26" TO 48" SUPPLEMENTAL PQ OO STANDARD NO. OO-ZD c c TYPICAL TRENCH SECTiON WITH DIMENSIONS AND COMPACTION ZONES MAX. TRENCH ZONE ALLOWABLE SLOPE OF tXCAVATION PER REQUIREMENTS OF CAL/OSHA. 7 OR MIN. TO 8 MAX. BENEATH PIPE 1" MIN. BENEATH 6CLL WHICHEVER IS GREATER. P.V.C. PIPE PIPE ZONE NOTES: 1. PERCENTAGES SHOWN EQUAL MINIMUM RELATIVE COMPACTION. 2. MINIMUM DEPTH OF COVER FROM TOP OF PIPE TO FINISH GRADE FOR ALL SANITARY SEWER INSTALLATIONS SHALL BE 3 FEET. FOR COVER LESS THAN 3". SPEOAL DESIGN ANO APPROVAL REQUIRED. 3. TRENCH ZONE BACKFILL SHALL BE PER SECTION 02223. NO ROCKS LARGER THAN 4" IN ANY DIMENSION WILL BE AUOWED IN BACKFILL. ASPHALT OR CONCRETE CHUNKS WIU NOT BE ALLOWED. 3/4" CRUSHED ROCK REV. APPROVED DATE CITY OF CARLSBAD iSk/^A+T '7ht%lnCi PIPE BEDDING AND TRENCH BACKFILL FOR SEWERS CITY ENGIMMR ^ DATE PIPE BEDDING AND TRENCH BACKFILL FOR SEWERS SUPPLEMENTAL r\ r- STANDARD NO. 0~U 1 REST ON BONNET OF VALVE. (2" MIN. CLEARANCE). 0 SECTION A-A DOMESTIC WATER NOTES: 1. IN NON-ROAD AREAS PUCE MARKER 3 POST NEXT TO VALVE BOX ASSEMBLY AS DIRECTED BY THE ENGINEER. ( SEE , DRAWING NO. 23 ). 2. ALL BURIED NUTS AND BOLTS SHALL BE WAX TAPE COATtD PER SPEC. 09902 SECTION B-B RECLAIMED WATER SEE DRAWING NO. 23 FOR GATE VALVE EXTENSION. UPPER SIDE OF UD TO RECIEVE 2 COATS OF PAINT SEE SPECIRCATIONS FOR PAINTING REQUIREMENTS, ( PAGE 4 ). ITEM DESCRIPTION SPEC/DWG 1 VAL BOX & COVER WITH NON-SKID C.l. COVER AND UFT HOLE. MARKFD "WATFR" 2 VAL. BOX & COVER FOR NORMALLY CLOSED VALVE. 3 VAL BOX & COVER MARKED "RECYCLED WATER". 4 8° C900 PVC OR ASPHALT COATED WELL CASING. 5 CONCRETE COLLAR IDENTIFY CONC. BY CLASS 560-C-3250 b POLYETh YLENE 1 INGASEMENT REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT VALVE BOX ASSEMBLY VALVE BOX ASSEMBLY CITY ENGIN^R ^ DATE VALVE BOX ASSEMBLY STANDARD DWG. NO. yy-|5 TRENCH WIDTH AT TOP OF TRENCH VARIES .MAXIMUM ALLOWABLE SLOPE OF EXCAVATION PER REQUIREMENTS OF CAL/OSHA m BACKFILL TRENCH ZONE WITH NATIVE EARTH BACKFILL OR IMPORTED MATERIAL 90% RELATIVE COMPATION* CDBACKFILL PIPE BASE AND PIPE ZONE WITH IMPORTED SAND 90% RELATIVE COMPATION I— HAUNCHING LIMITED A PIPE DIAMETER MIN. MAX. A r THROUGH 8" 6" 9" A 10" THROUGH 16" 8" 12" A 18" THROUGH 24" 10" 18" A 27" THROUGH 36" 12" 24" •IN PAVED AREA, TRENCH ZONE SHALL BE COMPACTED TO 95% MIN. NO SCALE ITEM DESCRIPTION SPEC/DWG 1 BEDDING AND BACKFILL MATERIAL SECT 02223 REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT If 111! --*ir I *.! * < — 1 n "7/y/\/nO TYPICAL TRENCH SECTION CITY ENGINfe DATE TYPICAL TRENCH SECTION STANDARD DWG. NO. V\/~2 TYPICAL TRENCH SECTION STANDARD DWG. NO. V\/~2 SIDEWALK CURB & GUTTER METER AND BALL VALVE BY DISTRICT NOTES: 1. CONTRACTOR SHALL ADJUST ANGLE VALVE & METER BOX TO E.G. AFTER SIDEWALK IS INSTALLED & APPROVED 2. DISTRICT WILL SET METER AND BALL VALVE 3 ALL COPPER JIONTS SHALL BE SILVER SOLDERED IN CONFORMANCE WITH SPECIFICATIONS. 4 TAP TO MAIN TO BE MINIMUM OF 24" FROM NEAREST COUPLING. FITTING. VALVE. BELL OR OTHER TAPS. 5. POSITON ANODE MIDWAY BETWEEN PIPELINE AND METER BOX. 6 INTERIOR OF METER BOX SHALL BE CLEAR OF DEBRIS TO DEPTH OF 12" AND CORP STOP FULLY EXPOSED NQN- DETAIL CONTIGUOUS SIDEWALK & CURB ITEM DESCRIPTION COPPER. (TYPE 'K' . SOFT) OUTLET ON PVC PRESSURE PIPE OUTLET ON AC PIPE OUTLET ON CML&C STEEL PIPE SPEC/DWG W-8 W-9 3 OUTLET ON DUCTILE IRON PIPE W-9 ANGLE METER STOP METER BOX AND COVER 1 (TRAFFIC AREA) METER BOX AND COVER (NON-TRAFFIC AREA) 30 LB. ZINC ANODE WITH ANODE LEAD WIRE W-25 REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT r WATER SERVICE CONNECTION FOR 5/8", 3/4" & 1" METERS CITY ENGINEH? ^ DATE r WATER SERVICE CONNECTION FOR 5/8", 3/4" & 1" METERS STANDARD DWG. NO. V\/"3 r WATER SERVICE CONNECTION FOR 5/8", 3/4" & 1" METERS STANDARD DWG. NO. V\/"3 ENCLOSURE PER CONNECT TO OUTLET ASSY 1. SEE SPECIRCATIONS FOR SOLDERING REQUIREMENTS. 2. SEE SPECIFICATIONS FOR PAINTING REQUIREMENTS. 3. SEE IMPROVEMENT PLANS FOR ASSEMBLY SIZE. 4. ALL VALVES AND FITTINGS SHALL BE SAME SIZE AS AIR VENT INLET 5. POSITON ANODE MIDWAY BETWEEN PIPEUNE AND VALVE BOX. ITEM DESCRIPTION SPEC/DWG ITEM DESCRIPTION SPEC/DWG 1 1" COPPER, (TYPE 'K' . SOFT). 2" COPPER SER. PIPE. (TYPE "K" SOFT 14 2" COPPER ADATER. COPPER SOLDER JOINT x MALE IPT. 0-300 PSI 2 OUTLET ON PVC PRESSURE PIPE w-8 14 2" COPPER ADATER. COPPER SOLDER JOINT x MALE IPT. 0-300 PSI 3 OUTLET ON AC PIPE w-8 15 2" FLARED TUBE STR CPLG, COPPER X MALE IPT. 0-150 PSI 4 OUTLET ON CML&C STEEL PIPE W-9 15 2" FLARED TUBE STR CPLG, COPPER X MALE IPT. 0-150 PSI 5 OUTLET ON DUCTILE IRON PIPE W-9 16 CONCRETE ANCHOR BLOCK WITH 2 CUBIC FEET 6 1" OR 2" ANGLE METER STOP 16 CONCRETE ANCHOR BLOCK WITH 2 CUBIC FEET 7 METER BOX & COVER (TRAFFIC AREA) 17 2" CL 125 CAST BRONZE 90* ELBOW WITH FEMALE IPT 8 METER BOX & COVER (NONTRAFFIC AREA) 18 2" BRASS PIPE. REGULAR WALL WITH MALE IPT 9 1" OR 7" HEAVY DUTY 19 30"x30"x6" CONCRETE PAD 10 COMBINATION AIR RELEASE. 1" OR 2" BRASS STREET "L" 20 2" COMB. AIR RELEASE AND VACUUM VALVE, FEMALE IPT 11 1" OR 2" X 6" BRASS NIPPLE 21 AVE ASSEMBLY ENCLOSURE 12 1" OR 2" SCHEDULE 40 PVC 21 AVE ASSEMBLY ENCLOSURE 13 BRASS METER COMPANION FLANGE. (BRASS NUTS AND BOLTS ON 2") 22 1" OR 2" METER STOP 13 BRASS METER COMPANION FLANGE. (BRASS NUTS AND BOLTS ON 2") 2" BRONZE BALL VAl VF REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT t^l)UCf''nJaiuiui^X* lIlJtJfK ABOVE SURFACE 1 & 2" AIR-VACUUM VALVE ASSEMBLY & APPURTENANCE CITY ENGINEy? ' DATE ABOVE SURFACE 1 & 2" AIR-VACUUM VALVE ASSEMBLY & APPURTENANCE STANDARD DWG. NO. VV~7 ABOVE SURFACE 1 & 2" AIR-VACUUM VALVE ASSEMBLY & APPURTENANCE STANDARD DWG. NO. VV~7 A.C. MAIN P.V.C. MAIN FOR WATER SERVICE CONNECTION f TYP. ) ITEM DESCRIPTION SPEC/DWG 1 DOUBLE BAND BRASS SERVICE SADDLE. 2 BRONZE DOUBLE STRAP SERVICE SADDLE. 3 CORP. STOP r WATER SERVICE. W-3 4 CORP. STOP 2" WATER SERVICE. W-4 5 CORP. STOP 1" AIR VACUUM VALVE ASSEMBLY. W-7 6 CORP. STOP 2" AIR VACUUM VALVE ASSEMBLY W-7 7 1" MANUAL AIR RELEASE ASSEMBLY W-5 8 2" BLOW-OFF MANUAL AIR RELEASE ASSEMBLY, W-5&6 9 2" MANUAL BLOW-OFF / AIR RELEASE ASSEMBLY, W-6&7 REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT OUTLETS ON A.C. OR P.V.C. MAIN FOR I INCH THRU 2 INCH ASSEMBLIES CITY ENGINI m DATE ) STANDARD DWG- NO. W-8 -il^'-"-'-*' •".•''1 D.I. MAIN STEEL MAIN FOR WATER SERVICE CONNECTION ( TYP. ) ITEM DESCRIPTION SPEC/DWG DOUBLE BAND BRASS SERVICE SADDLE, CORP, STOP 1 WATER SERVICE. W-3 CORP. STOP 2 WATER SERVICE. W-4 CORP. STOP 1 AIR VACUUM VALVE ASSEMBLY. W-7 CORP. STOP 2 AIR VACUUM VALVE ASSEMBLY, W-7 1" MANUAL AIR RELEASE ASSEMBLY. W-5 2 BLOW-OFF MANUAL AIR RELEASE ASSEMBLY. 2" BLOW-OFF / AIR RELEASE ASSEMBLY. W-6&7 W-6&7 NOT USED 10 3000 PSI FORGED STEEL COUPLING WELDED TO MAIN. W-14 REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT OUTLETS ON D.I. OR STEEL MAIN FOR 1 INCH THRU 2 INCH ASSEMBLIES CITY ENGINEER DATE OUTLETS ON D.I. OR STEEL MAIN FOR 1 INCH THRU 2 INCH ASSEMBLIES STANDARD DWG. NO, W~9 OUTLETS ON D.I. OR STEEL MAIN FOR 1 INCH THRU 2 INCH ASSEMBLIES STANDARD DWG. NO, W~9 FINISHED SURFACE (TYP.) I GATE VALVE. PVC & DIP NOTES: 1. SEE SPECIFICATIONS FOR BURIED aANGE AND VALVE REQUIREMENTS. 2. SEE DRAWING NO.I 9 FOR THRUST BLOCK BEARING AREAS. 3. ALL BURIED NUTS AND BttTS SHALL BE WAX TAPE COATED PER SECT 09902. TRENCH ELEVATION PVC PIPE TRENCH REINFORCING STEEL DETAIL. FiniNG O.D. TRENCH SECTION (TYPICAL) TRENCH ELEVATION STEEL PIPE TEM DESCRIPTION GATE VALVE SPEC/DWG POLYETHYLENE ENCASEMENT NO. 4 REINFORCING STEEL. CONCRETE THRUST/ANCHOR BLOCK. (3250 P.S.I.) 560-C-3250" VALVE BOX ASSEMBLY. W-19 W-13 REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT GATE VALVE INSTALLATION P.V.C, & STEEL PIPE. GATE VALVE INSTALLATION P.V.C, & STEEL PIPE. CITY ENGINES^? ^ DATE% GATE VALVE INSTALLATION P.V.C, & STEEL PIPE. STANDARD DWG. NO. W-|6 1 0 IS to E o 6 8 10 12 NOTES: Pipe Diometer in Inches 1. BASED ON 225, PSI TEST PRESSURE AND BEARING VALUES OF DRY SOILS. 2. VALUES FROM CURVES ARE FOR TEES AND DEADENDS, I.E. ; STRAIGHT LINE THRUST FOR 90- BEND: 1.4 VALUE FROM CURVE. FOR 45' BEND: 0.8 VALUE FROM CURVE. FOR 22 1/2" BEND: 0.4 VALUE FROM CURVE. 3. FOR CONDITIONS NOT COVERED BY CURVES, SPECIAL IWRUST WALLS. THRUST BLOCKS AND ANCHORS MUST BE CALCULATED AND APPROVED. 14 16 REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT THRUST BLOCK BEARING AREAS THRUST BLOCK BEARING AREAS aTY ENGIN^R ' DATE THRUST BLOCK BEARING AREAS STANDARD DWG. NO. ^''\() ZINC ANODE ANODE LEAD ABOVE GRADE CONNECTION ABOVE GRADE CONNECTION NOTES: 1. RISER PIPE SHALL BE WIRE BRUSHED TO CLEAN BRIGHT METAL. 2. PIPE CLAMP SHALL BE LOCATED ON RISER PIPE. 3. WIRE INSULATION SHALL BE STRIPPED TO A MINIMUM LENGTH TO CONNECT WIRE TO PIPE CLAMP. PACKAGED BACKFILL COMPOSITION: 75% GYPSUM 20% BENTONITE 5% SODIUM SULFATE INGOT WEIGHT: 30 LBS. PKGD. WEIGHT 70 LBS. APPROX. 9 ITEM DESCRIPTION SPEC/DWG 1 ANODE LEAD NO. 12 AWG STRD. COPPER WIRE W/ THW INSULATION 2 HEAT SHRINKABLE SLEEVE. 3 SILVER SOLDER CONNECTION. 4 1/4" DIAMETER GALVANIZED STEEL CORE. 5 2"X2"X30" ZINC ALLOY INGOT. 6 CLOTH BAG. 7 PACKAGED BACKFILL. 8 BRASS OR COPPER RISER PIPE. 9 BRASS OR COPPER PIPE CLAMP WITH SCREW TERMINAL. REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT ZINC ANODE AND CONNECTORS FOR r AND 2" WATER SERVICE CITY ENGINE EER ^ DAT DATE STANDARD DWG NO. VV~25 jf4«12" OC EA FACE 2 #4 EACH FACE & EACH SIDE OF PIPE 2 j(6 EACH FACE 3s 'EACH SIDE OF PIPE ANCHOR BLOCK SECTION 10' MIN. ANCHOR BLOCK ELEVATION SPEC/DWG ITEM DESCRIPTION STEEL PIPE, CML&C, WELDED JOINTS FLANGE X PUSH JOINT ADAPTOR 3 4 CONCRETE ANCHOR BLOCK WITH REINFORCING STEEL 1 THICK X 3 HIGH WELD STL RING REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT WELDED STEEL PIPE SECTION WITH THRUST WALLS FOR SLOPES AND DIPS CITY ENGINI EER DATE STANDARD DWG. NO. VV-3/f CONCRETE SUPPORT WALL (SEE NOTE 10) CASE A y^f' •^1" (25 mm) THICK / i iNr)l<;TllRRFD EiARTH ' EXPANSION JOINT / ^!^7« ^ cAMr, ni I FR '-1 (25 mm I SAND riuLurT CUSHION 6R APPROVED EXPANSION JOINT MATERIAL (SEE NOTE 8) CASE D OPTIONAL CLEANOUT (SEE NOTE 11)- CONCRETE SUPPORT WALL (SEE NOTE 10) CASE B ix^ANSIOI^ ST UNDISTURBED EARTK^ FILLER L r (25 mm) THICK EXPANSION JOINT RLLER UNDISTURBED EARTH 1" (25 mm) SAND CUSHION OR APPROVED EXPANSION JOINT MATERIAL (SEE NOTE 8) ~ UNDISTURBED EARTH SADDLE CASE C -1" (25 mm) SAND (25 mm) THICK CUSHION OR APPROVED EXPANSION JOINT EXPANSION JOINT FILLER MATERIAL (SEE NOTE 8) CASE F STANDARD PLANS FOR PUBUC WORKS CONSTRUCTION PROMULGATED BY THE PUBUC WORKS STANDARD. INC. GREENBOOK COMMITTEE 1884 REV. t8S6, 2009 HOUSE CONNECTION REMODELING USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION STANDARD PLAN 223-2 SHEET 1 OF 3 APPENDIX I STRIPING PLAN FOR MADISON STREET SOUTH OF GRAND AVENUE CITY OF CARLSBAD TRANSPORTATION DEPARTMENT TO: JOHN MAASHOFF - STREETS SUPERINTENDENT FROM: DOUG BILSE - CITY TRAFFIC ENGINEER \^ WORK ORDER NO. M-^f-^ DATE/<^-f BY^Lg^LE TR# 14-115 RBS/ORDI N/A W.O. #(s) (y^^f^^ LOCATION: ^/AP/SON S7??EEr S/O GffAND MmiZ PROJECT: PAMT RED CURB: DEUNEAJE NORTHBOUND TRAWL LANES JUSTIFICATION: IMPROVE FUNCTIONALITY OF INTERSECTION GRAND AVENUE EXISmC "STOP' LEGEND WORK TO BE DONE 0 PLEASE PAINT 48 FEET OF RED CURB. AS SHOMW, SO THAT MOTORISTS DO NOT PARK IN TRAVEL LANE Q) REMOVE 25-FOOT PORTION OF DOUBLE-YELLOW CENTERUNE THAT STICKS OUT INTO TRAVEL LANE (D PAINT AN 8-INCH WHITE CHANNELIZING UNE 50 FEET IN LENGTH PER CALTRANS DETAIL 38A. PAINT THE CHANNEUZING UNE 11 FEET FROM THE EXISTING DOUBLE-YEU.OW CENTERUNE. AS SHOWN. © PAINT A TfPE IV(L) ARROW AT SOUTH END OF LEFT-TURN LANE. AS SHOWN. (D PAINT A 'STOP' LEGEND IN RIGHT LANE, AS SHOWN. WHEN COMPLETED, RETURN TO: (Traffic Division) DATE COMPLETED Jim Gale Ext. 2755 _BY_ ^ APPENDIX J CITY OF CARLSBAD STANDARDS NOTES SIGNING AND STRIPING PLANS O APPENDIX J CITY OF CARLSBAD STANDARD NOTES FOR SIGNING AND STRIPING PLANS GENERAL NOTES: 1. The contractor is responsible for installation/replacement of all signing and striping. 2. All signing, striping and pavement markings shall conform to the California Manual on Uniform Traffic Control Devices (latest version), the Caltrans Standard Plans and Specifications (latest version), these plans and the Special Provisions. 3. All signing and striping is subject to the approval of the Transportation Director or his representative, prior to installation. 4. Any deviation from these signing and striping plans shall be approved by the Transportation Director or his representative prior to any change in the field. 5. All striping shall be reflective per Caltrans specifications. Striping shall be repainted two weelcs after initial painting. 6. All signage shall be reflective per ASTM Designation D4956 and shall use Type IV prismatic reflective sheeting (High Intensity Prismatic or equal) unless otherwise specified. R1-1 "STOP", R1-2 "YIELD", R2-1 "SPEED LIMIT" and street name signs shall use Type IX prismatic cube-corner reflective sheeting (Diamond Grade VIP or equal). 7. Prior to final acceptance of street improvements, all street striping and markings within a 500' perimeter of the construction project will be restored to a "like new" condition, in a manner meeting the approval of the City Inspector. 8. Exact location of striping and stop limit lines shall be approved by the Transportation Director or his representative prior to installation. 9. Contractor shall remove all conflicting painted lines, markings and pavement legends by grinding. Debris shall be promptly removed by the contractor. 10. All pavement legends shall be the latest version ofthe Caltrans stencils. 11. Limit lines and crosswalks shall be field located. Crosswalks shall have 10' inside dimension unless otherwise specified. 12. All crosswalks, limit lines, stop bars, pavement arrows and pavement legends shall be thermoplastic unless otherwise specified. Preformed thermoplastic arrows and legends shall not be acceptable. 13. All signs shall be standard size as shown in the California MUTCD unless otherwise specified. 14. Sign posts shall be square perforated steel tubing with breakaway base per San Diego Regional Standard Drawing M-45. 15. When a sign is attached to a pole, it shall be mounted using a standard City of Carlsbad approved mounting bracket with straps. 16. Existing signs removed by the contractor shall be delivered by the contractor to the City of Carlsbad Public Works Yard at 405 Oak Avenue. ^^^^ 17. All signs shown on these plans shall be new signs provided and installed by the contractor except ^ those signs specifically shown as existing to be relocated or to remain. 18. Fire hydrant pavement markers shall conform to the Catifornia MUTCD and San Diego Regional Standard Drawing M-19. 19. Lettering on ground-mounted street name signs on multi-lane streets with a speed limit greater than 40 mph shall be 8" upper case and 6" lower-case. Lettering on ground-mounted street name signs on streets with a speed limit of 25 mph or less shall be 4" upper case and 3" lower case. Lettering on all other ground-mounted street name signs shall be 6" upper-case and 4.5" lower-case. Lettering font shall be Clearview. Supplemental lettering such as suffixes, block numbers and directional arrows shall be at least 3" high. 20. Street name sign blanks shall be flat (non-extruded) and street name posts shall be a minimum 12- gage, ^y4" square tubing per San Diego Regional Standard Drawing M-45. 21. Where R6-1 "ONE WAY" signs are installed in a raised median, the bottom of the sign shall be 18" above the finished surface of the median. 22. Where 0M1-3 object markers are installed in a raised median, the bottom of the sign shall be 24" above the finished surface of the median. 23. Where R4-7 sign and 0M1-3 object marker are to be installed in a median less than 3 feet wide, the R4-7 sign shall be 18"x24" and the 0M1-3 object marker shall be 12"x12". 24. All median noses and flares shall be painted yellow. 25. Existing "STOP" and "STOP AHEAD" signs and pavement legends shall not be removed until traffic W signals are operational or until directed by the Transportation Director or his representative. 26. New "SIGNAL AHEAD" signs and pavement legends shall not be installed until traffic signals are operational or until directed by the Transportation Director or his representative. APPENDIX K NCTD DRAFT WORK PLAN NCTD Work Plan Grand Avenue Storm Drain Improvements November 11, 2014 Project Purpose The purpose ofthe overall proposed project is to alleviate drainage issues along Grand Avenue in the City of Carlsbad. This will be accomplished by replacing the existing storm drain system with lager pipes and also replacing several existing inlets. A small portion ofthe project would encroach into the North County Transit District (NCTD) right-of-way (ROW). The purpose of the work within the NCTD ROW is to simplify maintenance by replacing an existing grate inlet with a regional standard curb inlet. The location of the project is mile post 229.20 Project Scope The project extends along Grand from Jefferson Street to the State Street Alley, which is the northeast corner ofthe Carlsbad Visitor Information Center parking lot. Again, only a small portion ofthe overall project is proposed within the NCTD ROW (see Figure 1 for a vicinity map). The scope ofthe work within the NCTD ROW involves the replacement of an existing grate inlet with a new regional standard curb inlet. Minor curb and gutter improvements are also proposed to tie the new inlet into the existing surface improvements. New landscaping will also be provided to match the adjacent planter. All other work associated with the overall project will be performed outside of the NCTD ROW. The existing grated storm drain inlet will be replaced with a 9-foot, Type B-l curb inlet per SDRSD D-02, as detailed in Appendix I. iNLET LOCATION Figure 1 - Vicinity Map/Project Location NCTD - Grand Avenue Inlet Replacement Work Plan November 11, 2014 Page 1 Means and Methods The existing inlet will be demolished and removed. The new inlet will be constructed in the same location and the existing pipes will be reconnected to the new inlet. Minor curb, gutter, and AC improvements will provide a smooth transition from the new inlet to the existing surface improvements. Equipment The contractor will utilize standard construction equipment associated with demo and removal ofthe inlet. Contractor will select the methods and means to perform the removal ofthe existing grated inlet and the construction ofthe standard curb inlet. No equipment will be stored within the NCTD FtOW. Boring/Pothole Locations and Depths No boring or potholing will occur within the NCTD ROW. Schedule Although the overall project will take place over a longer timeframe, the work within the NCTD ROW is expected to begin April 1, 2015 and end April 3, 2015. Noise, Dust or Other Impacts from Work/Equipment The proposed work within the NCTD ROW will have minimal impacts. All construction activities will be performed in accordance with City regulations to best manage noise, dust, and other impacts and per the contract documents. The proposed improvements will result in improved drainage conveyance within the NCTD ROW since the new inlet has a higher capture capacity and is less likely to clog. This project is exempt for resource agency permits. The project must comply with Carlsbad Municipal Code Chapter 8.48-Noise, which regulates permitted hours for construction. All internal combustion engines used in the construction shall be equipped with mufflers in good repair when in use on the project with special attention to the City Noise Control Ordinance, Carlsbad Municipal Code Chapter 8.48. Throughout all phases of construction, including suspension of work, and until the final acceptance, the Contractor shall keep the site clean and free from rubbish and debris. The Contractor shall also abate dust nuisance by cleaning, sweeping and sprinkling with water, or other means as necessary. The use of water resulting in mud on public streets or right of way will not be permitted as a substitute for sweeping or other methods. When required by the Plans or Specifications, the Contractor shall furnish and operate a self-loading motor sweeper with spray nozzles at least once each working day for the purpose of keeping paved areas acceptably clean wherever construction, including restoration, is incomplete. Materials and equipment shall be removed from the site as soon as they are no longer necessary. Before the final inspection, the site shall be cleared of equipment, unused materials, and rubbish so as to present a satisfactory clean and neat appearance. All cleanup costs shall be included in the Contractor's Bid. NCTD - Grand Avenue Inlet Replacement Work Plan Page 2 November 11, 2014 Care shall be taken to prevent spillage on haul routes. Any such spillage shall be removed immediately and the area cleaned. Excess excavation material from catch basins or similar structures shall be removed from the site immediately. Sufficient material may remain for use as backfill if permitted by the Specifications. Forms and form lumber shall be removed from the site as soon as practicable after stripping. Failure ofthe Contractor to comply with the Engineer's cleanup orders may result in an order to suspend work until the condition is corrected. No additional compensation will be allowed as a result of such suspension. Cleanup and dust control required herein shall also be executed on weekends and other non-working days when needed to preserve the health safety or welfare ofthe public. The Contractor shall conduct effective cleanup and dust control throughout the duration ofthe Contract. The Engineer may require increased levels of cleanup and dust control that, in his/her sole discretion, are necessary to preserve the health, safety and welfare ofthe public. Cleanup and dust control shall be considered incidental to the items of work that they are associated with and no additional payment will be made therefore. The Contractor shall not discharge smoke, dust, or any other air contaminants into the atmosphere in such quantity as will violate the regulations of any legally constituted authority. Traffic Control Formal traffic control plans for the overall project (including the work within the NCTD ROW) will be developed priorto construction and submitted to the City and NCTD for review and approval. Community Outreach Program Community outreach for the overall project has been ongoing. Business owners have been made aware of the planned improvements. Additional outreach will be provided as the start of construction approaches. How Right of Way Will Be Accessed Access to the storm drain inlet is not inhibited by fencing or railway hazards. Access will be from Grand Avenue. Hazards, Spills and Safety Hazards, spills and safety concerns will be addressed as part of the construction of the overall Grand Avenue storm drain system upgrade and in accordance with City, State, and Federal regulation. Prior to construction, the contractor will submit a spill response plan for City review and approval per the contract documents. Materials that contain hazardous substances or mixtures may be required on the Work. A Material Safety Data Sheet as described in Section 5194 ofthe California Code of Regulations shall be requested by the Contractor from the manufacturer of any hazardous products used. NCTD - Grand Avenue Inlet Replacement Work Plan Page 3 November 11, 2014 Material usage shall be accomplished with strict adherence to California Division of Industrial Safety C requirements and all manufacturer warnings and application instructions listed on the Material Safety Data Sheet and on the product container label. The Contractor shall notify the Engineer if a specified product cannot be used under safe conditions. The proposed improvements will improve the long term safety in the area as it relates to drainage. Less frequent and less extensive ponding of stormwater runoff is expected. Emergencies Prior to construction of the overall project, the contract will coordinate with the City to ensure that emergency contacts are identified. In case of emergency, the contractor should call 9-1-1 and NCTD 24-hour security (760) 966-7600. NCTD - Grand Avenue Inlet Replacement Work Plan Page 4 November 11, 2014 APPENDIX I - CONSTRUCTION DETAILS Included within this appendix: 1. Grand Avenue Storm Drain Improvement Plans FINAL CONSTRUCTION PLANS FOR NORTHWEST QUADRANT STORM DRAIN IMPROVEMENT PROGRAM PROJECT NO. 6608 GRAND AVENUE CITY OF CARLSBAD CARLSBAD, CAUFORNIA an COUNCIL MATT HALL-MAYOR UARKPACKAm - MAYOR PRO TEU LORRAINE WOOD - COUNCIL MEMBER KEITH BLACKBURN. COUNOL MEMBER MKHAEL SCHUMACHER - COUNCIL MEMBER STEVEN R. SARKOZY • CfTy MANAGER JIM HOWELL. INTERIM PUBLIC WORKS DIRECTOR CONSULTING SOSO AVEMM ENCI^US. sunE 2tO CAHUUD. CAUFOWflA 0ZIK).43M CITY OP CARLSBAD I (01*0 awtq TTTIE SHEET 6606 li 457-4H EROSION (XNTROL fc STORMWATER MANAG£HENTS NOTFS ARBORIST NOT^^ :R UCMXHCT VEHICIES SHUX. sc UUITUNED Tl If SC*SOH. *U tCESSAHT UiTtRlilS SM*ll BC SIOCKPITO W n PROTICTtCN FROU TVC KUAHO OF CAVWG 0»CUHO DUflHH THE It NCCESSARV PKECWnOHS 10 PHQItCKW WBK. UCHr WD AHI OnKK ASSOOAIED OACWC r. UOHOAr !MBU FBOAT AHO HO tAaTHMOWNC OK OIKItKi W s ommc 1HE cajasL or NPLEMOIIMC »LUH$ nm OeTAMD ir A KMICH Of 1>< Al " a CMJio TO 1NE POSSBU eiosiQMX or or (laowcnouMi ixD UMXRCIKXHD) m Cf TXt CtHSniVCTIOM TO PCRUir tic ll NOT KHIMUE TO "CV OH TTC ABMIY IT or WltACt THAI THE CWTBACTOR CAH »KQU*t€Lr Pfi J. m fuLuHE or A IS HSTALUD. WAS NOT Al ytO]IU~T7H EQUIP EOIIPICNT 911 scm IMtOLE CDNSULTING •Company S090 AVENIDA ENCINM. SUITE 3tO CARLaoW], CAUFORNIA lOOOMIH I • FAX 7g0.4TS,fl1M - WWW.RBFjBm LEGETC fc ABBREVIATIONS CiTY OF CARLSBAD jl mOMMWTSTCmCflAUmKIVEkt^ GENB^'NOTES GRAND AVE STA 4401^1 (LOONNO EAST) WATER RELOCATION RBQHLi 1. PnjIlX BO rot DK AT M.L in i. -towviL v WN rtojj ee ro nc icAra^ GRAND AVE STA 9^22.40 (LOOKINQ NORTH) WATER RELOCATION PROFILE ijl ilf It GRAND AVE STA i2t<X32 (LOOKING EAST] RRE SERVICE PROFII F iHiT<uiD (o fw^iw ii.icf.iM3 momi'mwiit a. GRAND AVE STA 12*79.44 (LOONNG EAST) WATER RELOCATION PROFILE CONSTRUCTION NOTES UUTH rSMCITim SHUJ> K HAINrAIrO DM TK EXtSTIhC CUTTTK rUK.|IC IHtO CURB CUT a° Still?''''' 1 100' a .Ar 1 .IS' 70'; ; 1 1 r ovtuAi' ueroiuiwD BI A.C. OVERLAY • MATCH EXISTING PAVEMENT A.C. OVERLAY - MATCH CURB A nl ITTFR [NO DUMPING DRAINS TO OCEAN INLET aTH«H. CpNBULTINCS Icompany 7W.47 NBO AVENIDA EMOHAS, SUITE IM CARLSBAD. CALIFORNIA S»«-43H I • FAX7M.47Bgt« • nMw.RBFjxim RE'^SI'OTI DESCRIP III:rI LTTY OF CARLSBAD ll DETMS AND SECTIONS ^ T I i' """^^^H, ny<D • a or PIPE inft m so ajLim •flfwc OTOtBS.M CTS i i - i ^Rfis a fei X li 1 i se STORM DFIAIN PROFILE STORM DRAIN PiyiFILE STORM DRAIN PRORLE •• KMC:' Hcm 20' i I GRArtO AVENUE J i:r[> l«irc?«it» (rip>\ m S ^ 3: plii GENERAL NOTES: sii?ua: OHMSD omiHc CONSTT^UCTION NOTES OP..,IC, ® pEPu!a:^o^"TOi^'" '"^^ ''™ <§} TTPE B» iTDPU DBAIN OXHtOUI Ffjl ai CEPlAca. Tt€ VILVE 91*LL BE ITBIAILO) PEP SHIIHHD (U) PIPE BtmiNO « ® «.«:CT TO STCRU DRAIH DATA TABLE 5050 AVENBA ENCIW3, SUTT^ 250 CARLSBAD, CAUFORNIA B200I-UH ' FAX rOO 47S.01W •ww.RBFon CITY OF CARL'3BAD|[^ 6609 11 457-4H "3 ', 0. cjsl d:l ^ aioo-5j.» (j^ 50 it IS® STORM DRAIN PROFILE STORM PgglfjPfiqfILE (TYI.) j j®^*"" iCONSTRUCTION NOTES 10" APPENDIX II - NCTD ENCROACHMENT PERMIT APPLICATION Included within this appendix: 1. Standard Encroachment Permit Application 9 9 o TRANSIT DISTRICT NCTD PERMfT ID # FLAGGING AUTHORIZATION » NCTD Rac'd Date Project Location Applicant Information MilePost Start 1 MilePost End 229.20 Name of Applicant City of Carlsbad Street Address of Project (Closest Address) 421 Grand Avenue Mailing Address City of Carlsbad Engineering Department 1635 Faraday Avenue City Carlsbad, CA City, State, ZIP Carlsbad, CA Applicant Telephone 760-602-2756 Nearest Cross Sfreet(s) Grand Avenue {State Street Alley Engineer/PM RBF Consulting PM/Engineer telephone/e-mail 760-476-9193 Other Identifying Remarks g^^^^ ^^^-^ g^g^^ ^^^^^^^ corner of Grand Avenue and the State Street Alley. PM/Eng. Address, If different RBF Consulting 5050 Avenida Encinas, Suite 260 Carlsbad, CA 92008 THIS IS AN EMERGENCY pWOJtCT Yes flo Proiect Description PM/Eng. Address, If different RBF Consulting 5050 Avenida Encinas, Suite 260 Carlsbad, CA 92008 THIS IS AN EMERGENCY pWOJtCT Yes flo Date: Construction or use to begin April 1, 2015 Date: Expected Completion April 3, 2015 Wfio will do the w/ork? (Ust all) Contractor to be selected by the City of Carlsbad. Other agencies, entities, companies involved City of Carlsbad Fully Describe the ProjecL Include complete plans with specifications, calculations, maps, if applteable The scope ofthe work within the NCTD ROW involves the replacement of an existing grate inlet with a new regional standard curb inlet. Minor curb and gutter improvements are also proposed to tie the new inlet into the existing surface improvements. New landscaping will also be provided to match the adjacent planter. Ail other work associated with the overall project will be performed outside of the NCTD ROW. The existing grated storm drain inlet will be replaced with a 9-foot, Type B-1 curb inlet per SDRSD D-02 Standard Encroachment Permit Application NORTH COUNTY TRANSIT DISTRICT NCTDPERMmD# FLAGGING AUTHORIZATION # Spedfic (check all ttiat apply) NCTD Rec'd Date Description/Notes Temporary Use Permanent Easement On RR Right-of-Way Other NCTD Property New Construction Maintenance Work Improvement to Existing Communications Line Drainage Electrical supply Hazardous Materials High pressure gas Landscaping Livestock crossing Monitoring Well Overhead Work Description/Notes Pedestrian Overpass Pedestrian Underpass Private Crossing Public Crossing Sewer Signage Slope Work Storage ot materials Storage of Rail cars Storage of vehicles Storm Water Survey work Underground Utility relocation Wall, fencing, etc. Water Supply Standard Encroachment Permit Application Sherri Howard 'ubject: V .ocation: Start: End: Recurrence: Meeting Status: Organizer: Grind and Cap Traffic Control Yarrow Office Conference Room Thu 11/20/2014 8:00 AM Thu 11/20/2014 9:00 AM (none) Accepted Danny.McKie@kiewit.com All, We would like to meet to run through the grind and cap schedule cap traffic control plans • and then review the expectations for the grind and