HomeMy WebLinkAbout2007-12-11; Municipal Water District; 645; Funds for Maerkle Facility Improvements1 CARLSBAD MUNICIPAL WATER DISTRICT - AGENDA 645AB# MTG. 12/11/07 DEPT. ENG AUTHORIZATION TO APPROPRIATE FUNDS FOR MAERKLE FACILITY IMPROVEMENTS DEPT. HEAD CITY ATTY. CITY MGR. \jy* ^ RECOMMENDED ACTION: Adopt Resolution No. Improvements. ITEM EXPLANATION: 1309 authorizing the appropriation of funds for the Maerkle Facility Maerkle Dam reservoir and its auxiliary facilities are located in the northeast part of the City and are a critical part of the potable water supply system for the City. Maerkle Dam reservoir (formerly known as Squires Dam reservoir) was initially constructed in 1963. In the late 1980's and early 1990's, various auxiliary facilities were added, including a 10 million gallon concrete storage tank, transmission pipelines, a 33.5 mgd (million gallons per day) pump station, and chlorination facilities. In May 2007, staff commissioned a study to evaluate all the facilities at Maerkle Dam reservoir. The study report identified about 20 items at the site that need replacement to meet current code requirements for health and safety and to maintain reliability of this supply source. The items are summarized in Exhibit 2. Staff further evaluated the report to prioritize the improvements into first and second year implementation. On September 18, 2007, Council awarded a contract for the floating cover rainwater system replacement and cover cleaning. The rainwater system replacement and cover cleaning were initiated before the above-mentioned study as an immediate response to a California Department of Health inspection and the rainwater system condition. Therefore, this Maerkle Facility Improvements project does not include these two items. ENVIRONMENTAL IMPACT: This project is a Class 2 categorical exemption (replacement or reconstruction of existing structures or facilities) and is, therefore, exempt from environmental review pursuant to Section 15302 of the California Environmental Quality Act (CEQA). FISCAL IMPACT: In order to implement the recommended improvements, the replacement facilities need to be designed and bid documents prepared. The Table below summarizes the anticipated costs for the project. FOR CITY CLERKS USE ONLY BOARD ACTION: APPROVED DENIED CONTINUED D WITHDRAWN D AMENDED D CONTINUED TO DATE SPECIFIC D CONTINUED TO DATE UNKNOWN D RETURNED TO STAFF D OTHER - SEE MINUTES D Page 2 ITEM Design Construction Contingency Inspection PROJECT TOTAL COST CURRENT APPROPRIATION ADDITIONAL APPROPRIATION NEEDED ESTIMATED COSTS $225,000 $1,371,000 $137,100 $137,100 $1,870,200 $0 $1,870,200 These costs are an estimate of costs for implementation of all items in Exhibit 2 for first and second year implementation. This project is not in the current Fiscal Year 2007-2008 CIP. At the time of budget preparation for the 2007-2008 CIP the study to evaluate the needs at this facility was underway and sufficient information was not available to determine fiscal impacts. Staff is requesting that an appropriation from the Water Replacement Fund be approved at this time to finance the project. Sufficient funds are available in the Water Replacement Fund to accommodate the cost of this project. OPTIONS Staff has identified three possible options for the project: 1. Implement the project as defined by approving this agenda bill and directing staff to implement all improvements identified for the project. 2. Phase the project by authorizing replacement of the most critical components which include the variable frequency drives, chlorine gas scrubbers, lower access gate, and ammonia room chiller for a cost of about $1.18 million, and postpone the remaining project components to a future fiscal year. 3. Postpone the project to a future fiscal year. This will delay the improvements, impact the reliability of this water supply, and cause the facility to be out of compliance with safety codes and security requirements. EXHIBITS: 1. 2. 3. Location Map. Maerkle Dam Reservoir Facility Prioritization List. Resolution No. 1309 Facility Improvements. authorizing the appropriation of funds for the Maerkle DEPARTMENT CONTACT: Eva Plajzer 760-602-2787 eplai@ci.carlsbad.ca.us £xh i bi -f 1 LOCATION MAP NOF TO SOUf S/TE PROJECT NAME MAERKLE FACILITY IMPROVEMENTS EXHIBIT 1 DRAWN BY: SCOTT EVANS. CARLSBAD ENGINEERING DEPT. 11/20/06 C:\CAPITAL\PLAJZER\UAERKLE DAM COVER.DWG C_o+3 (0N _O DL o CD (0£ (0CN Q t oCQ ^ I OX « LJLI S coIt(U f\E-i0) Q. Q. E c.0 u ^ i 0•ju JSto Q. £ Co Iw Q. Q. £ 0 Q. •a row 2 "coo 8ro Q. 0 .0 ro CO Q. £ Osw (Replace VFDs and switchgear for pumpfNJVNJ .0 ro CO Q. £ <D (Replace/reinstall discharge piping air valcro1— rn i o .* O o c ro.0 u- 'roQ.0Cd fNI^ N croH o ">;ro.a4-*f/i (Replace joint sealant in 10 MG tank (we;0•J3 CO Q. £ 1— fl) 0 | 8ro Q.0K. 0roLL co 1'wb 8.Q. 13 (Replace chlorine dioxide generator0roLL cots .2 'wb 2LQ. U fl)vu T3'x0 T3 C Install SCADA monitoring system to chicgenerator'orou. cO'•s "I'S5b 13 ,_(Replace ammonia/monochlorite analyze& "oroLL co t> « 'wb 0 5 (install ammonia chillers.£• 'oroLL co'•sJBc 'wb Q.Q. •i-* 0 C !2c 8IDu/ o Remove existing scrubber and install chlcylinders& 'orou. co tj f'wb Q) 5 CD ao (Convert lower gas scrubber to dry type sfNIV M .£• 'oroLL cg t> £c'w b 0Q.Q. Wro0) 0c _o 0 2?JRemove chlorine evaporator and pressu(system"orou. co tj f'wb 1 5 COroD) 0_c _g 0 2 Remove chlorine evaporator and pressusystemcro1— o ^ roJQ-i-> ro c 0 0 roro0W ti 0oro Q.0o: "oroLLco 1 'wb 1! E0 fw O)c (install SCADA control of chloramine dosOj CO S0 0O •oro 2 ww08ro o en S3 D) o0 "w fNIV N Q) CO 20 0 w g-2 sro =C3) O "ro **~c< .sQ t36 •§Install security cameras (connected to Spump station, tank, upper and lower disiiand reservoir.B CO 20 0O (Install automatic rolling gatei_'o 0w0cn o QoCN (Underwater inspection of floating cover<nx 0) (UI Q. co o•c:O. 9 0) Q.E co D. 2o>SQ. 'c0)IIo co 38'5.C!(D O)O CN 1 RESOLUTION NO. 1309 2 A RESOLUTION OF THE BOARD OF DIRECTORS OF 3 CARLSBAD MUNICIPAL WATER DISTRICT (CMWD), AUTHORIZING THE APPROPRIATION OF FUNDS FOR THE 4 MAERKLE FACILITY IMPROVEMENTS. 5 WHEREAS, the Board has determined it necessary and in the public interest to 6 appropriate funds for the Maerkle Facility Improvements; and 7 WHEREAS, funds in the Water Replacement Fund are available to appropriate. 8 NOW, THEREFORE, BE IT RESOLVED by the Carlsbad Municipal Water District Board 9 of the City of Carlsbad, California, as follows: 10 1 • That the above recitations are true and correct. 2. That the Finance Director is authorized to appropriate $1,870,200 from the Water Replacement Fund for the Maerkle Facility Improvements. 13 14 15 16 17 18 19 20 21 '" 22 '" 23 '" 24 '" 25 '" 26 '" 27 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 PASSED, APPROVED AND ADOPTED at a Special Meeting of the Board of Directors of the Carlsbad Municipal Water District of the City of Carlsbad on the 11th day of December, 2007, by the following vote: AYES: Board Members Lewis, Kulchin, Hall, Packard and Nygaard NOES: None ABSENT: None DE A LEWS, resdent ATTEST: LORRAINE M. WOOD, Secretary /CCAI \ vO11""'/,( ' /$m&./i**"*"^_ ifc« **— o • °