HomeMy WebLinkAbout2009-10-27; Municipal Water District; 701; Maerkel pump station upgradeCARLSBAD MUNICIPAL WATER DISTRICT - AGENDA BILL AB# 701 MTG. 10/27/09 DEPT. ENG ACCEPTANCE OF BIDS AND AWARD OF CONTRACT FOR THE CONSTRUCTION OF MAERKLE PUMP STATION UPGRADE PROJECT NO. 5009-B DEPT. HEAD "j^-f^T CITY ATTY. ^ CITY MGR. (JA-*"" RECOMMENDED ACTION: Adopt Resolution No. 1381 Maerkle Pump Station Upgrade Project No. 5009-B. ITEM EXPLANATION: accepting bids and awarding contract for the construction of Maerkle Dam reservoir and its auxiliary facilities are located in the northeast part of the City and are a critical part of the potable water supply system for the City. Maerkle Dam reservoir (formerly known as Squires Dam reservoir) was initially constructed in 1963. In the late 1980's and early 1990's, various auxiliary facilities were added, including a 10 million gallon concrete storage tank, transmission pipelines, a 33.5 million gallons per day pump station, and chlorination facilities. In May 2007, staff commissioned a study to evaluate all the facilities at Maerkle Dam reservoir. The study report identified 20 priority items that need replacement to meet current code requirements for health and safety and to maintain reliability of this water supply source. These items were presented to the Board via Agenda Bill No. 645 on December 11, 2007, and are summarized in Exhibit 2. Additional agenda bills will be presented to the Board for consideration when the plans and specifications are completed and appropriate implementation schedule windows are identified. The Maerkle Pump Station Upgrade Project involves high priority items 2 and 19. Item 2 replaces and upgrades electrical components at the pump station, such as variable frequency drives, switches, soft starters, controls, relays, lights, etc. The existing pumps were constructed in 1992. The existing units are requiring increased attention to remain operable and have reached the end of their useful life. To minimize the risk of pump failure and inability to deliver water, the existing electrical components need to be replaced. Item 19 provides for improvements at the two existing gates to the site to provide for a more secure site. On July 28, 2009, the Board adopted Resolution No. 1366 approving plans and authorizing to advertise for bids. On September 17, 2009, seven (7) bids were received. The bids are summarized in Table 1. The lowest responsive bidder, Neal Electric Corporation dba: Nealectric, Inc. submitted a bid in the amount of $188,850. Staff has completed the review of all contract documents and has determined that they are in order. Therefore, staff recommends that Neal Electric Corporation dba: Nealectric, Inc. be awarded the contract. ENVIRONMENTAL IMPACT: This project is a Class 2 categorical exemption (replacement or reconstruction of existing structures or facilities) and is, therefore, exempt from environmental review pursuant to Section 15302 of the California Environmental Quality Act (CEQA). DEPARTMENT CONTACT: Eva Plajzer 760-602-2787 eva.plajzer@carlsbadca.gov FOR CITY CLERKS USE ONLY BOARD ACTION: APPROVED DENIED CONTINUED WITHDRAWN AMENDED K/ D D D D CONTINUED TO DATE SPECIFIC CONTINUED TO DATE UNKNOWN RETURNED TO STAFF OTHER - SEE MINUTES D D D D Page 2 TABLE 1 - SUMMARY OF BIDS CONTRACTOR Neal Electric Corp. dba: Nealectric Inc. Falcon General Engineering, Inc. Fore Engineering Construction, Inc. Newest Construction Company Saturn Electric Axis Control Inc. Sloan Electric Company BUSINESS LOCATION Poway, CA Vista, CA Tustin, CA San Diego, CA San Diego, CA Irvine, CA San Diego, CA TOTAL BID AMOUNT $188,850 $218,403 $241,991 $280,000 $281,340 $298,647 $306,297 FISCAL IMPACT: Table 2 shows the current status of the Maerkle Facilities Improvements Project No. 5009. These expenditures are for all the items shown as completed in Exhibit 2. TABLE 2 - MAERKLE FACILITY IMPROVEMENTS PROJECT NO. 5009 TASK DESCRIPTION Design Construction, Inspection, Materials Testing TOTAL APPROPRIATED TO DATE $260,000 $1,875,200 $2,135,200 EXPENDITURES/ ENCUMBRANCES TODATg $135,321 $597,989 $733,310 REMAINING BALANCES $124,679 $1,277,211 $1,401,890 The Engineer's Estimate for the construction of the pump station upgrade project was prepared by Krieger and Stewart Inc. in January 2009, and totals $331,000. The engineer's estimate is based on bid data for similar projects received by CMWD in 2008 and 2007, with adjustments for current conditions. The significant decrease in the bid amount as compared to engineer's estimate can be attributed to the current economic conditions and reduction in costs for materials. The total construction cost is shown in Table 3. TABLE 3 - PROJECT CONSTRUCTION COST MAERKLE FACILITIES IMPROVEMENTS PROJECT NO. 5009-B PUMP STATION UPGRADE Construction Contract (Neal Electric Corp.) Construction Contingency Construction Management and Inspection Testing & Start-up TOTAL CONSTRUCTION COSTS PRQJEGT AVAILABLE BALANCE ADDITIONAL APPROPRIATION ANTICIPATED FOR CONSTRUCTION ESTIMATED COSTS $188,850 $40,000 $20,000 $30,000 $278,850 $1,401,890 -0- PageS Sufficient funds exist in the Water Replacement Fund to construct these improvements. There are also sufficient funds for the remaining items in Exhibit 2. This project was advertised with prevailing wage requirements because it is a CMWD project and not subject to the City of Carlsbad charter regulations. EXHIBITS: 1. Location Map. 2. Maerkle Dam Reservoir Facility Prioritization List. 3. Resolution No. 1381 Accepting Bids and Awarding Contract for the Construction of Maerkle Pump Station Upgrade Project No. 5009-B. LOCATION MAP NOT TO SCALE SITE PROJECT NAME MAERKLE PUMP STATION UPGRADE PROJECT PROJECT NUMBER 50096 EXHIBIT 1 DRAW BY: SCOTT EVANS, CARLSBAD ENGINEERING DEPT. 2/18/09 H:\CAPITAL IMPROVEMENT PROGRAU\5009 UAERKLE SITE IMPROVEMENTS\PLANS 4 EXHIBITS\5009A.DWG EXHIBIT 2 Maerkle Dam Reservoir Facility Prioritization List Item No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Item Replace controls and PLC for pump station Replace VFDs and switchgear for pump station Replace/reinstall discharge piping air valves Repair leak in 10 MG tank Replace joint sealant in 10 MG tank (west bay) Replace flow meter Replace chlorine dioxide generator Install SCADA monitoring system to chlorine dioxide generator Replace ammonia/monochlorite analyzer Install ammonia chillers Remove existing scrubber and install dry type scrubber Remove existing scrubber and install dry type scrubber Remove chlorine evaporator and pressure chlorine gas system Remove chlorine evaporator and pressure chlorine gas system Replace joint sealant in 10 MG tank (east bay) Install SCADA control of chloramine dosing system Install security lighting on access road Install security cameras (connected to SCADA) at gates, pump station, tank, upper and lower disinfection facilities, and reservoir. Install automatic rolling gate Underwater inspection of floating cover Location Pump Station Pump Station Pump Station lOMGTank lOMGTank Pump Station Upper Disinfection Facility Upper Disinfection Facility Lower Disinfection Facility Lower Disinfection Facility Upper Disinfection Facility Lower Disinfection Facility Upper Disinfection Facility Lower Disinfection Facility lOMGTank Lower Disinfection Facility General Site General Site General Site 200 MG Reservoir Implementation Priority 1 1 2 1 2 2 1 1 1 1 1 1 2 2 2 2 2 2 1 1 Status Completed Requesting approval to award Completed Completed Under investigation Under investigation Completed Under design Completed Completed Completed Completed Completed Completed Under investigation Completed Under investigation Under investigation Requesting approval to award Completed n\ 1 RESOLUTION NO. 1381 2 A RESOLUTION OF THE BOARD OF DIRECTORS OF CARLSBAD MUNICIPAL WATER DISTRICT (CMWD), 3 ACCEPTING BIDS AND AWARDING THE CONTRACT FOR THE CONSTRUCTION OF MAERKLE PUMP STATION UPGRADE 4 PROJECT NO. 5009-B. 5 WHEREAS, the Board has determined it necessary and in the public interest to construct 6 the electrical component at Maerkle Pump Station and update the entrance gates to the site; and 7 WHEREAS, on July 28, 2009, through the adoption of Resolution No. 1366, the Board 8 approved the plans and specifications for furnishing of all labor, materials, tools, equipment, transportation, and other expenses necessary and incidental to the construction of the Maerkley Pump Station Upgrade Project No. 5009-B; and 10 WHEREAS, seven (7) sealed bids were received September 17, 2009, for the project; and 11 WHEREAS, the lowest responsive, responsible bid for the project was submitted by Neal 12 Electric Corporation dba: Nealectric, Inc. in the amount of $188,850; and 13 WHEREAS, there are sufficient funds in the Water Replacement Fund to complete the 14 project. 15 NOW, THEREFORE, BE IT RESOLVED by the Carlsbad Municipal Water District Board 16 of Directors of the City of Carlsbad, California, as follows: 17 1. That the above recitations are true and correct. 18 2. That the bid in amount of $188,850 submitted by Neal Electric Corporation dba: Nealectric, Inc. is herby accepted and that the President is hereby authorized to execute a contract19 with Neal Electric Corporation dba: Nealectric, Inc. for the construction of the Maerkle Pump Station 20 Upgrade Project No. 5009-B, in accordance with the plans, specifications, and contract 21 documents referred to herein. 22 3. That the Executive Manager is hereby authorized to approve construction change 23 orders up to $40,000 for Project No. 5009-B. 24 4. That the award of contract is contingent upon the bidder submitting the lowest 25 responsive bid executing the required contract and submitting the required bonds and insurance 26 policies, as described in the contract, within twenty (20) days of adoption of this resolution. The 27 Executive Manager may grant reasonable extensions of time. 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 PASSED, APPROVED AND ADOPTED at a Special Meeting of the Carlsbad Municipal Water District of the City of Carlsbad on the 27th day October of, 2008, by the following vote: AYES: Board Members Lewis, Kulchin, Hall, Packard, and Blackburn. NOES: None. ABSENT: None. ATTEST: *.:fn ~ 7