Loading...
HomeMy WebLinkAbout1989-05-17; Planning Commission; ; MP 177A - AVIARA PACIFICAPPLICATION COMPLETE DATE: STAFF REPORT DATE: May 17, 1989 TO: PLANNING COMMISSION FROM: PLANNING DEPARTMENT SUBJECT: MP - 177(A) - AVIARA PACIFIC - Request for approval of an Amendment to Master Plan 177 (Pacific Rim Country Club and Resort) to revise Specific Planning area development standards for property located in Local Facilities Management Zone 19, north of Batiquitos Lagoon and west of E1 Camino Real. I. RECOMMENDATION That the Planning Commission ADOPT Resolution No. 2863 recommending (1) APPROVAL of MP-177(A), as modified, based on the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND On December 22, 1987, the City Council approved the Pacific Rim Country Club and Resort Master Plan (MP-177). Master Plan - 177 includes Planning Area specific development standards for each of the 32 Planning Areas of the Master Plan. As proposed, the developer, Hillman Properties is requesting that three of the Planning Area Development Standards be amended as discussed below. These three proposed amendments will be referred to as Sections 1, 2 and 3 within this report. (See Exhibit "A", Developer's Proposal) 1. SECTION I - PLANNING AREAS 4, 8, 14 and 24 For these four, small lot Single Family Planning Areas, Master Plan-177 specifies that "The minimum building separation shall be 10 feet between one story structures, 15 feet between one and two story structures and 20 feet between two or more story structures." Hillman Properties requests that this building separation standard be deleted and replaced by the following requirements: (1) That the minimum distance between structures within these small lot, single family planning areas shall comply with Section 21.45.090(5) of the Planned Development Ordinance. Where there are fewer than 10 structures in a row the separation between dwelling units shall vary from 10 feet to 14 feet, with a Planning Area - wide average of 12 feet and (2) that developments proposed within these Planning Areas comply with the recently adopted (by Planning Commission) "Guidelines For Small -Lot Single Family Detached Projects." 2. SECTION 2 PLANNING AREA 9 Master Plan-177 specifies that for this multifamily residential planned unit development, "All structures and parking shall be setback a minimum of 20 feet from internal streets." r MP-177(A) AVIARA PACIFIC MAY 17, 1989 PAGE 2 Hillman Properties requests that this standard be qualified whereby front setbacks on attached structures, with side -loaded garages may be varied to a 15 foot average with a 10 foot minimum." 3. SECTION 3 PLANNING AREA 3 For this standard lot (7500 SF) single family residential planning area, Master Plan 177 specifies that: "To encourage height variation for this neighborhood, 10 of the units shall not exceed a height of 18 feet above finished grade." Hillman Properties requests that this height standard be replaced with the following; "To encourage height variation for this neighborhood at least 2 of the units (Those within the Seaport Viewshed) shall not exceed a height of 18 feet above finished grade, and all of the units shall exhibit substantial roofline variation." III. ANALYSIS 1. SECTION 1 PLANNING AREAS 4, 8, 14 & 24 At the time that the existing building separation guidelines were incorporated into Master Plan 177, there existed a City staff and Planning Commission concern regarding the appearance of small lot, Single Family Planned Development Projects that had already been constructed under the former City Standards (minimum of 10 feet between structures). The City staff and Planning Commission, were concerned that these projects appeared overbuilt and that by increasing the required separation between dwelling units from ten feet to fifteen or twenty feet, overall project appearance would be enhanced. In view of this concern, the Planned Development Ordinance was amended in 1987 to require that: "When more than ten structures in a row front or back on a street, the distance between two and three story structures shall not be less than twenty feet and the distance between two-story and one-story structures shall not be less than fifteen feet." Since that time, the overall City staff and Planning Commission understanding of the problem of "large dwelling units on small lots" has evolved whereby the Planning Commission adopted "Architectural Guidelines for small lot Single Family detached units (February 15, 1989). It is staffs opinion that these guidelines, which will supplement the existing development standard, of the Planned Development Ordinance should be adequate (except in highly visible areas) to enable quality small lot single family project design within Carlsbad. Overall, staff recommends support of amended building separation standards (as modified below) for Planning Areas 4, 8, 14 and 24 in that those projects proposed within those Planning Areas (4, 8, 14 and 24) will exceed the existing building separation development standards of the Planned Development Ordinance, and the recently adopted Architectural Guidelines for Small Lot Single Family Detached Units." As proposed by the developer, the required building separation (regardless of whether there are 10 structures in a row) will range between 10 to 14 feet (with an average of 12 feet). Staff agrees that the architectural guidelines adopted by the Planning Commission could allow for a reduction in the MP-177(A) AVIARA PACIFY MAY 17, 1989 PAGE 3 Master Plan requirement of 20' between buildings. Staff does not agree with the 10' minimum requested by the developer. Staff feels the Master Plan should still be greater than other areas of the City and would recommend a minimum of 12 feet between buildings and an average separation of 14 feet. 2. SECTION 2 PLANNING AREA 9 Overall, staff recommends support of this amendment to Planning Area 9 because (1) this amendment request, to allow reduced frontyard setbacks (average of 15 feet with a 10 foot minimum) for attached, multifamily dwelling units, with side - loaded garages, would still be more restrictive than the existing Planned Development Ordinance, and (2) because this amendment should enable the applicant to create a more diverse and aesthetically appealing street scene, and (3) this would only apply to Planning Area 9. 3. SECTION 3 PLANNING AREA 3 At this time staff is unable to recommend support of the applicants request to reduce the number of one story units within Planning Area 3 from 10 to 2 because staff does not have adequate information to make this decision. This development standard (10 one story dwelling units) was incorporated within this Planning Area for purposes of ensuring that existing views from the adjacent Seaport development were preserved. In fact, the preservation of these views is a Special Design Criteria of this Planning Area. Up until now, the applicant has not provided any evidence to staff which justifies modification of this section. Staff has proposed an additional change to the height section of area 3 (p. 81 of the Master Plan). Staff has put a maximum height of 20 feet (at peak) to single story structures and has indicated more clearly the intent to have the single story structures adjacent to the Seaport Development. In summary, staff is recommending approval of the Master Plan Amendment only with the following suggested modifications as discussed above: 1. Section I, the reduction in building separation be modified to allow a 12 foot minimum with a 14 foot average. 2. Section 2, no modifications proposed. 3. Section 3, Reject the applicant's proposal to reduce the number of one story structures from 10 to 2 and modify page 81 of the Master Plan to establish a maximum height of 20 feet measured to the highest point of the roof for single story structures and that these single story structures be located adjacent to the Seaport development. Finally, staff is recommending an addition to page 41 of the Master Plan (The Architectural Guidelines - Condition 11) which would require that any modifications to the Guidelines when incorporated into the code shall also be reflected in the Master Plan. MP-177(A) AVIARA PACK • MAY 17, 1989 PAGE 4 IV. ENVIRONMENTAL REVIEW An Environmental Impact Report [EIR 83-2(A)] has been certified for this property as part of the Pacific Rim Country Club and Resort Master Plan. Since no major changes are proposed with this project, the Planning Director has determined that this project will not have a significant effect on the environment and, therefore, has issued a Notice of Prior Compliance on April 21, 1989. ATTACHMENTS 1. Planning Commission Resolution No. 2863 2. Location Map 3. Background Data Sheet 4. Environmental Document 5. Exhibit "A", Developer's Proposal 6. Exhibit "B", dated May 17, 1989 and revised May 9, 1989 7. Ordinance No. CD:lh April 24, 1989 PALOMAR AIRPORT Project Site Boundary .. P o`rse Alga Road AVIARA Q: 0 LA COSTA Batiquitos Lagoo� PACIFIC — La Costa Ave OCEAN �----- LEUCADIA City of Carlsbad AVIARA PACIFIC MP-177(A) BACKGROUND DATA SHEET CASE NO: MP-177(A) APPLICANT: AVIARA PACIFIC REQUEST AND LOCATION: AMENDMENT TO MP-177 TO REVISE SPECIFIC PLANNING AREA DEVELOPMENT STANDARDS. LEGAL DESCRIPTION: PORTIONS OF SECTIONS 22 26 27 28 33 34 AND 35 IN TOWNSHIP 12 SOUTH RANGE 4 WEST SAN BERNARINO MERIDIAN IN THE CITY OF CARLSBAD COUNTY OF SAN DIEGO STATE OF CALIFORNIA APN: Acres 1000 Proposed No. of Lots/Units GENERAL PLAN AND ZONING Land Use Designation RLM/RM Density Allowed Density Proposed Existing Zone PC Proposed Zone PC Surrounding Zoning and Land Use: Zoning Site PC North LC/PM Land Use VACANT BIRTCHER PACIFIC BUS CNTR South OS BATIOUITOS LAGOON East LC/R-1-7500 SEAPORT West LC/R-a-7500 SPINNAKER HILLS PUBLIC FACILITIES School District CARLSBAD Water CARLSBAD Sewer CARLSBAD EDU's Public Facilities Fee Agreement, Date N/A ENVIRONMENTAL IMPACT ASSESSMENT Negative declaration, issued E.I.R. Certified, dated Other, NOTICE OF PRIOR COMPLIANCE jEIR 83-2(A)) APRIL 21, 1989 2075 LAS PALMAS DRIVE CARLSBAD, CA 92009-4859 C2itV of Tarlobab PLANNING DEPARTMENT PUBLIC NOTICE OF PRIOR ENVIRONMENTAL COMPLIANCE Please Take Notice: TELEPHONE (619) 438-1161 The Planning Department has determined that the environmental effects of the project described below have already been considered in conjunction with previously certified environmental documents and, therefore, no additional environmental review will be required and a notice of determination will be filed. Project Title: MP-177(A) PACIFIC RIM COUNTRY CLUB AND RESORT. Project Location: The 1000 acre property is located north of Batiquitos Lagoon, between I-5 and E1 Camino Real. Project Description: An amendment to Master Plan 177 to revise sideyard setback standards for small lot single family planned unit developments (Planning areas 4, 8, 14 and 24) to be consistent with the recent adapted architectural guidelines for small lot planned unit developments. Justification for this determination is on file in the Planning Department, Community Development, 2075 Las Palmas Drive, Carlsbad, California 92009. Comments from the public are invited. Please submit comments in writing to the Planning Department within ten (10) days of date of publication. Dated: April 21, 1989 �(.��t_.�'_�- '✓ �' MICHAEL J. HONZMILLER Case No.: MP-177(A) Planning'Director Applicant: AVIARA PACIFIC Publish Date: April 21, 1989 CD:lh 9 Exhibit A MP 177(A) MASTER PLAN - 177 PROPOSED AMENDMENT WORDING 2011 PALOb1AR AIRPORT ROAD SUITE 206 CARLSBAD. CALIFORNIA 92009 (619) 931-1190 F:%x:(619) 931-7950 g- within the Pacific Rim Country Club and Resort, the color white will be used extensively either on its own or mixed with other colors. In essence, all wall surface colors with the exception of Planning Area 28 will be a tint of white. Therefore, the overall wall surface scheme will be based on color value rather than hue. This means the entire range of hues will be permissible in order to meet personal and market demands. Stain colors will be gauged similarly. A more detailed description of these colors and a color palette will be included in the Pacific Rim Country Club and Resort Design Guidelines. Optional colors may be allowed in single family detached planning areas provided that they are found to be compatible with the colors and character of the Master Plan area by the Planning Department. As discussed under roof treatments above, roof colors shall be in the red to reddish -brown to orange range. Color variations in a roof tile piece or plane are allowed, provided a compatible appearance is maintained. GUIDELINES - Detached Products - PUD 1. In projects where there are three 2 story units in a row situated less than 15 feet apart, at least one of the three units shall have a single story building edge with a depth of not less than 10 feet adjacent to one of the other units. The roof covering the single story element shall be substantially lower than the roof for the 2 story element to the unit (this is not intended to preclude long shed -type roofs falling to a single -story element.) 2. In projects where there are three 2 story units in a row situated between 15 and 20 feet apart, at least one of the three units shall have a single story building edge with a depth of not less than 5 feet adjacent to one of the other unit. The roof of the single story element shall be substantially lower than the roof for the two story element of the building (this is not intended to preclude long shed -type roofs falling to single -story element). 3. On a project basis, thirty-three percent (33%) of all units shall have a single story edge for forty percent (40%) of the perimeter of the building. For the purpose of this guideline the single story edge shall be a minimum depth of three feet (P ). The units qualifying under the 33% shall be distributed throughout the project. 41 4. 4. For at least 50% of the units in a project, there shall be at least three separate building planes on street side elevations of lots with 45 feet of frontage or less, and four separate building planes on street side elevations of lots with a frontage greater than 45 feet. The minimum offset in planes shall be 18 inches and shall include but not be limited to building walls, windows and roofs. The minimum depth between the faces of the forward -most plane and the rear plane on the front elevation shall be 10 feet and a plane must be a minimum of 30 sq. ft. to receive credit under this section. 5. Rear elevations shall adhere to the same criteria outlined in number 4 above for front elevations except that the minimum depth between front and back planes on the rear elevation shall be 3 feet. 6. At least 50% of the units in a project shall have one side elevation where there are sufficient offsets or cutouts so that the side yard setback averages a minimum of 7 feet. 7. Projects with an average lot less shall limit the number garages to 75% of the plans units with three car garages garages, three door garages, 12") two door garages. size of 5,000 sq. ft. or of units with three car in the project. Project shall be a mix of two door and offset (2 planes min. 8. Fifty percent (50%) of exterior openings (doors/windows) shall be recessed or projected a minimum of 2" and shall be with wood or colored aluminum window frames (no mill finishes). 9. Variety in Roof Framing Direction The predominant roof framing for each floor plan shall exhibit directional variety to the other floor plans of the same project. Notes: a) For the purpose of these guidelines a single story element shall be defined as a plate line of 12 feet or less. b) In addition, when a percentage of units is described in the guidelines the intent is to have that percentage spread throughout the entire project. Landscaping a. Community Landscape Concept The major components of the landscape design are the resort area, golf course, lagoon shoreline, hillsides and streetscape. 42 0 � 1 0 1) Resort Area The resort area (Planning Areas 2, 9, 10 and 11) creates the dominant landscape character and theme to be reflected throughout the community. It will resemble a hillside village within a natural landscape with the introduction of agricultural groves at its periphery and ornamental plants in its interior garden areas. Cars on the parking deck are screened with trellis rows that recall vineyards. The hotel courtyard is paved with rough stone and exposed aggregate concrete and is framed by a pergola with flowering vines. It is connected by a narrow garden consisting of ramps, stairs, low terrace walls, naturalized plantings and a linear water feature. 2) Golf Course Golf course areas limit turf to fairways, tees and greens. Naturalized vegetation provide a transition to existing slopes. Hedgerows or eucalyptus follow the valley slope. Water features shall provide obstacles to the golfer as well as create an attractive natural connection to Batiquitos Lagoon. 3) Lagoon Shoreline The lagoon shoreline shall be preserved and in areas of disturbance or decline the naturalized setting shall be reestablished. 4) Hillsides Hillsides throughout the project will be carefully planned due to their extremely sensitive nature and visibility. Four concepts will apply to these areas: - All development shall comply with the City's Hillside Ordinance (Chapter 21.95). - All development shall comply with the grading and natural resource preservation policies of the underlying Local Coastal Programs. - Existing tree groves and vegetation will be preserved to the greatest extent feasible. - Erosion control techniques shall be employed where needed. 43 - Views to and from the_ lagoon and golf course shall be preserved to the greatest extent feasible. View preservation is illustrated on Exhibit IV-3. - The landscape treatment shall present a visually cohesive appearance, since hillsides will be viewed from distant areas such as La Costa Avenue, El Camino Real, Interstate 5 and surrounding neighborhoods. 43-A PLANNING AREA 3: SINGLIk'AMILY RESIDENTIAT, • DESCRIPTION: This 5.0 acre planning area consists of single family residential homes. This neighborhood includes a 150-foot wide public utility corridor along the northeast boundary which will provide a 5.2 acre passive recreation area and pedestrian trail. DEVELOPMENT STANDARDS: R-1-7500 All development in Planning Area 3 shall conform to the standards of the R-1 one -family residential zone (Carlsbad Municipal Code, Chapter 21.10) unless otherwise noted in this chapter. USE ALLOCATION: Maximum of 27 residential units. (5.4 DU/AC) PERMITTED USES: The following uses are allowed within this planning area. Single family detached residential units along with passive and active recreation uses. Duplex units are expressly prohibited within this planning area. SITE DEVELOPMENT STANDARDS: Height: To encourage height variation for this neighborhood at least l& 2 of the units shall not exceed a height of 18 feet above finished grade and all of the units shall exhibit substantial roofline variation. The maximum height in this planning area is 28 feet as defined by Section 21.04.065 of the Carlsbad Municipal Code. Lot Size: The minimum lot size shall be 7,500 square feet. The minimum lot width shall be 60 feet except that lots fronting on knuckles or cul-de-sacs shall have a minimum frontage pursuant to the Carlsbad Municipal Code, Chapter 20.16.010. At least 150 of the lot area shall be reserved for open space. This open space shall be located in the rear yard and shall not exceed a gradient of 5%. Setbacks: To encourage a variety of front yard setbacks, the minimum setback shall be 20 feet with at least 8 of the units having a 24-foot front yard setback and being dispersed throughout the planning area. All other setbacks shall be pursuant to Chapter 21.10 of the Carlsbad Municipal Code. Parking: Parking shall conform to the standards of Chapter 21.44 of the Carlsbad Municipal Code. SPECIAL DESIGN CRITERIA: Design: All community -wide design standards described in Section A of Chapter IV shall be embodied in the architecture of this planning area. The following specific guidelines shall also be included for this planning area. PLANNING AREA 4: SINGL#r'AMILY RESIDENTIAL • DESCRIPTION: This 27.7 acre planning area located at the easterly entrance to the project will include small lot single family residential homes. The planning area is separated from Planning Area 5 to the southwest by a 150-foot wide public utility corridor which functions as an open space buffer. Primary access is taken from Alga Road which forms the northwest boundary of the site. DEVELOPMENT STANDARDS: PD All development in this planning area shall conform to the standards of the Planned Development Ordinance described in Chapter 21.45.090 of the Carlsbad Municipal Code unless otherwise noted in this chapter. USE ALLOCATION: Maximum of 103 residential units. (4.5 DU/AC) Recreation facilities. PERMITTED USES: The following uses are allowed within this single family detached residential units. shall be included in this planning area. prohibited. SITE DEVELOPMENT STANDARDS: planning area: small lot Private recreation facilities Duplex units are expressly Height: The maximum height in this planning area is 28 feet as defined by Section 21.04.065 of the Carlsbad Municipal Code. A minimum of 30% of all dwelling units shall be a maximum of one story (18 feet) in height. Lot Size: The minimum lot size for lots along the east side of the oak preserve/open space corridor shall be 6,000 square feet. The minimum lot size for lots to the west of the corridor shall be 5,000 square feet. The minimum lot width shall be 60 feet for minimum 6,000 square foot lots or greater, and 50 feet for lots less than 6,000 square feet except that lots which face onto cul-de-sacs or knuckles shall be 35 feet. The minimum lot size for lots adjacent to the Seaport development shall be 7,500 square feet. Setbacks: All structures shall be setback a minimum of 50 feet from the Alga Road right-of-way. A 20-foot front yard setback shall be required. Corner lots shall have a 10-foot side -yard setback along the side street which shall be landscaped. The minimum side -yard shall be 5 feet. J'he �is�s�ee-}ae�weer�-s�agle-s�s�y-s-��t�e�tt�es-small-�e�-He-less-�Y�a�-��-�ee�. l._5-faet. Internal setbacks shall comply with Chapter IV, Section 3, g of this Master Plan. Rear yard setbacks shall be a minimum of 15 feet of useable area (slope does not exceed 100). All 7,500 square foot lots shall comply with the standards of Chapter 21.16.010 of the Carlsbad Municipal Code. Parking: Parking shall conform to the standards of Chapter 21.44 of the Carlsbad Municipal Code. MW PLANNING AREA 8: SING0 FAMILY RESIDENTIAL DESCRIPTION: This 27.3 acre planning area provides for small lot single family residential units. Homes in this neighborhood are bounded by Alga Road to the north and Pacific Rim Drive to the east and south. The area overlooks Batiquitos Lagoon to the south and is adjacent to the 17th fairway of the golf course. DEVELOPMENT STANDARDS: PD All development in Planning Area 8 shall conform to the development standards of the PD ordinance as described in Chapter 21.45.090 of the Carlsbad Municipal Code unless otherwise noted in this chapter. USE ALLOCATION: Maximum of 75 residential units. (2.7 DU/AC) Private recreation facilities are required in conjunction with the residential units. PERMITTED USES: Single-family detached residential units are allowed in this planning area. Private recreation facilities are required. SITE DEVELOPMENT STANDARDS Height: The maximum height allowed in Planning Area 8 is 28 feet. All heights shall be determined per Section 21.04.065 of the Carlsbad Municipal Code. A variety of building heights is required for this planning area to provide visual interest. Lot Size: The minimum lot size for this planning area shall be 4,500 square feet. The minimum lot width shall be 40 feet except that lots which front on cul-de-sacs or knuckles shall have 35-foot minimum widths. Setbacks: The minimum setback for all structures from the Alga Road right-of-way shall be 50 feet and Pacific Rim Drive shall be 30 feet. The minimum front yard setback from internal streets shall be 20 feet. sae-.sto-r-y-.2.9-ZQe-t_ -f'-e-r- tva--e-r-tee--shy � is ems-. Internal setbacks shall comply with Chapter IV, Section 3,g of this Master Plan. All other setbacks shall be in conformance with Section 21.45.090(b) of the Carlsbad Municipal Code. Parking: Parking shall conform to the standards of Chapter 21.44 of the Carlsbad Municipal Code. SPECIAL DESIGN CRITERIA: Design: All community -wide design standards described in Section A of Chapter IV shall be embodied in the architecture of this planning area. The following specific guidelines shall also be included for this planning area. 101 PLANNING AREA 9: MULTI -FAMILY RESIDENTIAL DESCRIPTION: This 32.5 acre planning area provides multi -family residential housing. DEVELOPMENT STANDARDS: PD All development in Planning Area 9 shall conform to the development standards of the PD Ordinance (Carlsbad Municipal Code, Chapter 21.45.090) unless otherwise noted in this chapter. USE ALLOCATION: Maximum of 100 multi -family residential units. (3.1 DU/AC) Private recreation facilities shall be required in this planning area. PERMITTED USES: Multi -family residential housing. Recreational facilities. SITE DEVELOPMENT STANDARDS: Height: The maximum height shall not exceed 35 feet. All heights shall be determined per Section 21.04.065 of the Carlsbad Municipal Code. At least 50% of the structures in this Planning Area shall be no more than two stories in height. Where three story -structures are proposed, adequate structural relief and roofline variation shall be incorporated into the structure to reduce the mass. Setbacks: A minimum 50-foot landscaped setback shall be maintained for all structures along Alga Road. Parking shall be setback a minimum of 35 feet from Alga Road provided that it is fully screened. All front yard setbacks shall be per Section 21.45.090(b) of the Carlsbad Municipal Code. All buildings shall be located a minimum of 20 feet from the planning area boundary. A minimum building separation of 10 feet shall be maintained for one-story structures, 15 feet for one and two-story structures and 20 feet for two or more story structures. All structures and parking shall be setback a minimum of 20 feet from internal streets, except where turn -in, side loaded garages are utilized, then a 15-foot minimum setback is allowed. Parking: Parking shall conform to the standards of Chapter 21.44 of the Carlsbad Municipal Code. SPECIAL DESIGN CRITERIA: Design: All community -wide design standards described in Section A of Chapter IV shall be embodied in the architecture of this planning area. The following specific guidelines shall also be included for this planning area: * The architecture of all structures shall be compatible with that of the hotel. -105- PLANNING AREA 14: SINGLIWAMILY RESIDENTIAL • DESCRIPTION: This 20.9 acre planning area includes small lot single family detached homes. The area is located on the north side of Pacific Rim Drive across the street from the 1st hole of the golf course. Homes in this neighborhood will also overlook the golf course to the west and the east. DEVELOPMENT STANDARDS: PD All development in Planning Area 14 shall conform to the standards of the PD Ordinance (Carlsbad Municipal Code, Chapter 21.45.090) unless otherwise noted in this chapter. USE ALLOCATION: Maximum of 52 residential units. (2.5 DU/AC) Private recreation facilities shall be required in this planning area. PERMITTED USES: Single family detached residential units are allowed in this planning area. Recreational facilities. SITE DEVELOPMENT STANDARDS: Height: The maximum height allowed in this planning area is 24 feet. All heights shall be determined per Section 21.45.065 of the Carlsbad Municipal Code. A variation in one and two-story homes shall be required along Pacific Rim Drive. Lot Size: The minimum lot size for Planning Area 14 shall be 6,000 square feet. The minimum lot width shall be 60 feet except that lots located on knuckles or cul-de-sacs shall have a minimum width of 35 feet. Setbacks: All structures shall be setback a minimum of 30 feet from Pacific Rim Drive. The minimum rear yard setback shall be 15 feet (slope does not exceed 100). All other setbacks shall conform to Section 21.45.090(b) of the Carlsbad Municipal Code. the-}abeee-beweea-ewe-sey-sefeeg-shall-e-be-less bhee-l�-feed:--the-d�afaaee-bebweea-ewe-abe�y-ab�eete�eg-shall-web-he-lesg- theR-2-9-feet r-The -dfsbaeee-between-eRe-sterzy-eed-fwe-afepy-afFeeberes-shall seb-be-less-bha-l-feef r Internal setbacks shall comply with Chapter IV, Section 3,g of the Master Plan. Parking: Parking shall conform to the standards of Chapter 21.44 of the Carlsbad Municipal Code. SPECIAL DESIGN CRITERIA: Design: All community -wide design standards described in Section A of Chapter IV shall be embodied in the Architecture of this planning area. The following specific guidelines shall also be included for this planning area: 125 PLANNING AREA 24: SINOL FAMILY RESIDENTIAL DESCRIPTION: This 53.9 acre planning area located at the northwest entrance to the Master Plan area will include small lot single family detached homes. The intersection of Poinsettia Lane and Alga Road is located at the northwest corner of the planning area. A 150-foot wide public utility corridor is located in the northwest portion of this neighborhood. DEVELOPMENT STANDARDS: PD All development in this planning area shall conform to the development standards of the PD Ordinance (Carlsbad Municipal Code, Chapter 21.45.090) unless otherwise noted in this chapter. USE ALLOCATION: Maximum of 193 residential units (3.6 DU/AC) Recreational facilities are required. PERMITTED USES: Single family detached residential units. Private recreation facilities are required in conjunction with the residential units. SITE DEVELOPMENT STANDARDS: Height: The maximum height allowed in this planning area is 28 feet as defined by Section 21.04.065 of the Carlsbad Municipal Code. Lot Size: The minimum lot size shall be 5,000 square feet. The minimum lot width shall be 50 feet, except that lots which front on knuckles or cul-de-sacs shall have a minimum frontage of 35 feet. Setbacks: All dwelling units shall be setback a minimum of 50 feet from the Alga Road right-of-way and 50 feet from the Poinsettia Lane right-of-way7. The standards front yard setback shall be 20 feet. In order to provide a variety of front yard setbacks, a minimum of 60 units shall have 24-foot setbacks. da-spa-R-ee-be-twee s gee--S*-o-r-- -s-h-a-1-1- 4.o-t- be- a s-s- t tia - zte'n- f . 4-1-s- aeee- 4et;aeAea- ztwQ- s4:o e4: ems--64ia-u- a .- bQ--IQZ.S- -than- tWJ--Q t'Y .feet . -Zhe-d s4:a EE- bE wE ea- oae-a it two--s tQr.u.Qt- b -lam- -t- -fi7ftZen 7Ee'e-'t: Internal setbacks shall comply with Chapter IV, Section 3,g of the Master Plan. Rear yard setbacks shall be a minimum of 15 feet of usable area (slope does not exceed 10%). All dwelling units shall be located a minimum of 25 feet from the westerly planning area boundary. Parking: Parking shall conform to the standards of Chapter 21.44 of the Carlsbad Municipal Code. 163 EXHIBIO'B" May 17, 1989 (As Revised by Staff May 9, 1989) (As Revised by the Planning Commission May 17, 1989) CHAPTER IV. COMMUNITY DEVELOPMENT STANDARDS Page 41 shall be amended to incorporate a new Section g. Architectural Guidelines for Planned Unit Development Detached Products, directly following Section f. Colors. AMENDED PAGE 41 SHALL READ AS: g. Architectural Guidelines for Planned Unit Development Detached Products 1. In projects where there are three 2 story units in a row situated less than 15 feet apart, at least one of the three units shall have a single story building edge with a depth of not less than 10 feet adjacent to one of the other units. The roof covering the single story element shall be substantially lower than the roof for the 2 story element to the unit (this is not intended to preclude long shed -type roofs falling to a single -story element.) 2. In projects where there are three 2 story units in a row situated between 15 and 20 feet apart, at least one of the three units shall have a single story building edge with a depth of not less than 5 feet adjacent to one of the other unit. The roof of the single story element shall be substantially lower than the roof for the two story element of the building (this is not intended to preclude long shed -type roofs falling to single - story element). 3. On a project basis, thirty-three percent (33%) of all units shall have a single story edge for forty percent (40%) of the perimeter of the building. For the purpose of this guidelines the single story edge shall be a minimum depth of three feet (3'). The units qualifying under the 33% shall be distributed throughout the project. 4. For at least fifty per cent (50%) of the units in a project, there shall be a least three separate building planes on street side elevations of lots with 45 feet of frontage or less, and four separate building planes on street side elevations of lots with a frontage greater than 45 feet. The minimum offset in planes shall be 18 inches and shall include but not be limited to building walls, windows and roofs. The minimum depth between the faces of the forward -most plane and the rear plane on the front elevation shall be 10 feet and a plane must be a minimum of 30 square feet to receive credit under this section. 5. Rear elevations shall adhere to the same criteria outlined in number 4 above for front elevations except that the minimum depth between front and back planes on the rear elevation shall be 3 feet. 6. At least fifty percent (50%) of the units in a project with minimum 5' sideyards shall have one side elevation where there are sufficient offsets or cutouts so that the side yard setback averages a minimum of 7 feet from the property line. Exhibit "B" May 17, 1989 Page 2 7. Projects with an average lot size of 5,000 sq. ft. or less shall limit the number of units with three car garages to seventy-five percent (75%) of the plans in the project. Project units with three car garages shall be a mix of two door garages, three door garages, and offset (2 planes min. 12") two door garages. 8. Fifty percent (50%) of exterior openings for every dwelling unit (doors/windows) shall be recessed or projected a minimum of 2" and shall be with wood or colored aluminum window frames (no mill finishes). 9. Variety in roof framing direction shall be required. 10. All architecture shall abide by the design parameters identified in the Aviara Design Manual. 11. Any changes or modification regarding these guidelines within Section 21.45 of the Carlsbad Municipal Code shall also be reflected in this Master Plan. The predominant roof framing for each floor plan shall exhibit directional variety to the other floor plans of the same project. Notes: a) For the purpose of these guidelines a single story element shall be defined as a plate line of 12 feet or less. b) In addition, when a percentage of units is described in the guidelines the intent is to have that percentage spread throughout the entire project. CHAPTER V. PLANNING AREA DEVELOPMENT STANDARDS AMENDMENTS: PAGE 81 PRESENTLY READS AS: Height: To encourage height variation for this neighborhood at least 10 of the units shall not exceed a height of 18 feet above finished grade. The maximum height in this planning area is 28 feet as defined by Section 21.04.065 of the Carlsbad Municipal Code. AMENDED PAGE 81 SHALL READ AS: Height: To encourage height variation for this neighborhood at least 10 of the units shall not exceed a height of 18 feet above finished grade (maximum 20 feet of the roof peak). The maximum height in this planning area is 28 feet as defined by Section 21.04.065 of the Carlsbad Municipal Code. These 10 single story units shall be located on lots 121, 122 and other lots as determined by the Planning Director. Exhibit "B" May 17, 1989 Page 3 170elalr�'7:»11►II 011.11IT.W31 Setbacks: All structures shall be setback a minimum of 50 feet from the Alga Road right- of-way. A 20-foot front yard setback shall be required. Corner lots shall have a 10-foot side -yard setback along the side street which shall be landscaped. The minimum side -yard shall be 5 feet. The distance between single story structures shall not be less than 10 feet. The distance between two and one story structures shall not be less than 15 feet. Rear yard setbacks shall be a minimum of 15 feet of useable area (slope does not exceed 10%). All 7,500 square foot lots shall comply with the standards of Chapter 21.16.010 of the Carlsbad Municipal Code. AMENDED PAGE 85 SHALL READ AS: Setbacks: All structures shall be setback a minimum of 50 feet from the Alga Road right- of-way. A 20-foot front yard setback shall be required. Corner lots shall have a 10-foot side -yard setback along the side street which shall be landscaped. The distance between structures shall comply with Section 21.45.090(5) of the Planned Development Ordinance. Where there are fewer than 10 structures in a row, the separation between dwelling units shall be a minimum of 12 feet and shall average 14 feet. Otherwise, structural setbacks for lots less than 7500 square feet in area shall comply with Chapter IV, Section 3, g of this Master Plan and Section 21.090.45(b) of the Carlsbad Municipal Code. Rear yard setbacks shall be a minimum of 15 feet of useable area (slope does not exceed 10%). All 7,500 square foot lots shall comply with the standards of Chapter 21.16.010 of the Carlsbad Municipal Code. PAGE 101 PRESENTLY READS AS: Setbacks: The minimum setback for all structures from the Alga Road right-of-way shall be 50 feet and Pacific Rim Drive shall be 30 feet. The minimum front yard setback from internal streets shall be 20 feet. The minimum building separation is 10 feet between one story structures, 15 feet between one and two story structures and 20 feet for two or more story structures. All other setbacks shall be in conformance with Section 21.45.090(b) of the Carlsbad Municipal Code. AMENDED PAGE 101 SHALL READ AS: Setbacks: The minimum setback for all structures from the Alga Road right-of-way shall be 50 feet and Pacific Rim Drive shall be 30 feet. The minimum front yard setback from internal streets shall be 20 feet. The distance between structure, shall comply with Section 21.45.090(5) of the Planned Development Ordinance. Where there are fewer than 10 structures in a row, the separation between dwelling units shall be a minimum of 12 feet and shall average 14 feet. Otherwise structural setbacks shall comply with Chapter IV, Section 3g. of this Master Plan and Section 21.45.090(b) of the Carlsbad Municipal Code. Exhibit "B" May 17, 1989 Page 4 PAGE 125 PRESENTLY READS AS: Setbacks: All structures shall be setback a minimum of 30 feet from Pacific Rim Drive. The minimum rear yard setback shall be 15 feet (slope does not exceed 10%). All other setbacks shall conform to Section 21.45.090(b) of the Carlsbad Municipal Code. The distance between one story structures shall not be less than 10 feet. The distance between two story structures shall be not less than 20 feet. The distance between one story and two story structures shall not be less than 15 feet. AMENDED PAGE 125 SHALL READ AS: Setbacks: All structures shall be setback a minimum of 30 feet from Pacific Rim Drive. The minimum rear yard setback shall be 15 feet (slope does not exceed 10%). The distance between structures shall comply with Section 21.45.090(5) of the Planned Development Ordinance. Where there are fewer than 10 structures in a row, the separation between dwelling units shall be a minimum of 12 feet and shall average 14 feet. Otherwise, structural setbacks shall comply with Chapter IV, Section 3g of this Master Plan and Section 21.45.090(b) of the Carlsbad Municipal Code. PAGE 163 PRESENTLY READS AS: Setbacks: All dwelling units shall be setback a minimum of 50 feet from the Alga Road right-of-way and 50 feet from the Poinsettia Lane right-of-way. The standard front yard setback shall be 20 feet. In order to provide a variety of front yard setbacks, a minimum of 60 units shall have 24-foot setbacks. The distance between single story structures shall not be less than ten feet. The distance between two story structures shall not be less then twenty feet. The distance between one and two story structures shall not be less than fifteen feet. Rear yard setbacks shall be a minimum of 15 feet of usable area (slope does not exceed 10%). All dwelling units shall be located a minimum of 25 feet from the westerly planning area boundary. AMENDED PAGE 163 SHALL READ AS: Setbacks: All dwelling units shall be setback a minimum of 50 feet from the Alga Road right-of-way and 50 feet from the Poinsettia Lane right-of-way. The standard front yard setback shall be 20 feet. In order to provide a variety of front yard setbacks, a minimum of 60 units shall have 24-foot setbacks. The distance between structures shall comply with Section 21.45.090(5) of the Planned Development Ordinance. Where there are fewer than 10 structures in a row, the separation between dwelling units shall be a minimum of 12 feet and shall average 14 feet. Otherwise, structural setbacks shall comply with Chapter IV, Section 3g of this Master Plan and Section 21.45.090(b) of the Carlsbad Municipal Code. Rear yard setbacks shall be a minimum of 15 feet of usable area (slope does not 0 • Exhibit "B" May 17, 1989 Page 5 exceed 10%). All dwelling units shall be located a minimum of 25 feet from the westerly planning area boundary. PAGE 105 PRESENTLY READS AS: Setbacks: A minimum 50-foot landscaped setback shall be maintained for all structures along Alga Road. Parking shall be setback a minimum of 35 feet from Alga Road provided that it is fully screened. All front yard setbacks shall be per Section 21.45.090(b) of the Carlsbad Municipal Code. All buildings shall be located a minimum of 20 feet from the planning area boundary. A minimum building separation of 10 feet shall be maintained for one-story structures, 15 feet for one and two-story structures and 20 feet for two or more story structures. All structures and parking shall be setback a minimum of 20 feet from internal streets. AMENDED PAGE 105 SHALL READ AS: Setbacks: A minimum 50-foot landscaped setback shall be maintained for Alga Road. Parking shall be setback a minimum of 35 feet fro that it is fully screened. All front yard setbacks sh 21.45.090(b) of the Carlsbad Municipal Code. All buildings minimum of 20 feet from the planning area boundary. separation of 10 feet shall be maintained for one-story str one and two-story structures and 20 feet for two or more st structures and parking shall be setback a minimum of 20 streets. However, setbacks on attached structures with sid be varied to a 15 foot average with a 10 foot minimum. CD:lh exhibitb.avi e all structures along m Alga Road provided all be per Section shall be located a A minimum building uctures, 15 feet for ory structures. All feet from internal -loaded garages may