Loading...
HomeMy WebLinkAbout2015-06-17; Planning Commission; ; PUD 14-05|CDP 14-18|MS 14-08 - OCEAN BREEZE The City of Carlsbad Planning Division A REPORT TO THE PLANNING COMMISSION Item No. Application complete date: February 19, 2015 P.C. AGENDA OF: June 17, 2015 Project Planner: Shannon Werneke Project Engineer: Steve Bobbett SUBJECT: PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE – Request for approval of a Planned Development Permit, Coastal Development Permit and Minor Subdivision to allow for the demolition of an existing single-family home and the construction of three (3) detached, two-story, single-family, air space condominium units (ranging from 5,234 to 5,522 square feet) and an accessory recreation building on property located at 608 Chinquapin Avenue, within the Mello II Segment of the Local Coastal Program and Local Facilities Management Zone 1. The project qualifies as a CEQA Guidelines Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption. This project is not located within the appealable area of the California Coastal Commission. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7108 APPROVING Planned Development Permit (PUD 14-05), Coastal Development Permit (CDP 14-18), and Minor Subdivision (MS 14-08) based on the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND The 0.93-acre infill site is located on the north side of Chinquapin Avenue, west of the intersection of Linmar Lane and Chinquapin Avenue (see Attachment No. 2), and approximately ¼ mile east of the railroad. The site is currently developed with a vacant single-story, single-family home. Topographically, the site gently slopes from north to south from a high point at 49.5 feet above mean sea level (AMSL) at the northeast corner of the site to 44.3 feet AMSL at the southerly property line adjacent to Chinquapin Avenue. A number of masonry walls, which are proposed to remain, currently border the perimeter of the property. Two walls with a combined height of nine (9) feet (i.e., three and six-foot-tall walls) are located along the northern property line, while a six (6) foot tall wall is located along the eastern and western property lines. The proposed project includes a request to subdivide the 0.93-acre site into three (3) airspace condominium units with one common area lot. Development of the site includes the demolition of the single-family home and the construction of three (3) detached, two-story, single-family air space condominium units ranging in size from 5,234 to 5,522 square feet (SF), as well as a 1,547 SF recreation clubhouse and a 144 SF gazebo. Access to the site is proposed to be provided by a 24-foot-wide driveway, which will be enhanced with stamped concrete. As the depth of the driveway exceeds 150 feet (i.e., 338 feet deep), a turn-around area is provided to meet Fire Department requirements. In addition, a vehicle access gate is proposed to be located 20 feet back from the front property line. While the proposed units are being reviewed and analyzed as single-family air space condominium units, the applicant has indicated the intention of ultimately operating three (3) residential care facilities for the elderly (i.e., persons over the age of 60), each of which will serve six or fewer persons. This intent has been communicated to the surrounding residential community, and was disclosed as part of the Early Public Notice process. 2 PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE June 17, 2015 Page 2 Pursuant to Section 21.10.020 of the Carlsbad Municipal Code (CMC), residential care facilities for six or fewer persons are permitted by right in the One-Family Residential (R-1) zone; there is no limit or lineal separation requirements between residential care facilities for six or fewer persons in the Zoning Code. Pursuant to CMC Section 21.04.300, a residential care facility is defined as follows: “Residential care facility” means a state authorized, certified or licensed family care home, foster home or group home serving mentally disordered or otherwise handicapped persons, or dependent or neglected children where care is provided on a twenty-four-hour-a-day basis. It is important to note that this allowance in the Zoning Code mirrors the state regulations, which require the city to permit the residential care facilities for six or few persons by right. Further, the state regulations indicate that there are no separation requirements which could preclude an overconcentration of the residential care facilities for six or fewer persons (California Health and Safety Code, §1520.5). Therefore, it is legal to propose three residential care facilities adjacent to one another, on a single lot in the R-1 zone and pursuant to the Planned Development Ordinance. Each of these units will be required to be licensed and monitored by the state. Consequently, staff’s analysis of the proposed project is strictly limited to the project’s compliance with Title 20 (Subdivision Ordinance) and Title 21 (Zoning Ordinance). Therefore, staff is required to review this project as a single-family condominium product to ensure that the project complies with standards such as setbacks, building height, parking, building coverage, etc. In addition, the project is also reviewed for compliance with the design and neighborhood compatibility guidelines included within City Council Policy No. 44 and No. 66. The three airspace condominium units are plotted in a detached, single-family configuration, with the front elevations facing towards the east (i.e., facing the drive aisle). Each unit is two stories tall and includes an attached two-car garage. The same floor plan is proposed for each of the units and includes a total of six (6) bedrooms and bathrooms on the first floor and two bedrooms and one shared bathroom on the second floor. The bedrooms on the first floor will be occupied by the residents of the residential care facility, while the two bedrooms on the second floor will be occupied by staff members who will be operating the facility. In addition to the attached two-car garage, three additional parking spaces including one van accessible parking space, are provided on-site. Proposed Condo 1, which is located closest to Chinquapin Avenue (setback 28 feet from the front property line), is proposed to be 5,522 SF and is designed in the Craftsman style. It contains several of the typical Craftsman elements, including horizontal siding, projecting wood ridge rafters, double-hung windows and a river rock base. A first floor porch, as well as a second floor enclosed “porch”, are also proposed and add relief to the façade as viewed from Chinquapin Avenue. The color palette consists of earth tones with hints of green which complement the Craftsman architectural style. Proposed Condo 1 has a maximum height of 25’-2” with a 4:12 pitched roof. Proposed Condo 2 is designed with a Spanish/Mediterranean style and is proposed to be 5,234 SF. The design incorporates an off-white stucco with traditional contrasting Spanish roof tiles. The interior stairway is designed to allow for an architectural tower element, which is a complementary feature of the architectural style. A terracotta stone trim creates a baseline for the bottom of the first floor windows and curved window treatments; wood balcony elements are also incorporated into the design. Proposed Condo 2 has a maximum height of 25’-6” with a 4:12 pitched roof. PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE June 17, 2015 Page 3 Condo 3 is designed with a Cape Cod architectural style and includes a blue-accented color palette and a mixture of materials including composite shingles, stone veneer, horizontal siding, double-hung windows, and window shutters. Proposed Condo 3 has a maximum height of 24”-3” with a 4:12 pitched roof. Since the proposed units are intended to be owned by one company and operated as residential care facilities, there is no exclusive use area associated with each unit. The underlying lot and air space condominium units will be owned by one person/entity and are not intended to be sold separately (but could be in the future). The common area primarily includes, but is not limited to, the private driveway clubhouse, guest parking area, fencing/walls, landscaping, lighting and a sidewalk. Table A below includes the General Plan designations, zoning and current land uses of the project site and surrounding properties. TABLE A Location General Plan Designation Zoning Current Land Use Site Residential Low Medium Density (RLM, 0-4 du/ac) One Family Residential (R-1) Vacant, single-story, single family home North RLM R-1 Two-story, single-family home South RLM R-1 Single-story, single-family homes East RLM R-1 Two-story, single-family homes (5 adjacent to property) West RLM R-1 Single-story, single-family homes (3 adjacent to property) Table B below includes 1) the project site’s gross and net acreage; 2) the number of dwelling units allowed by the General Plan’s Growth Management Control Point (GMCP) density; and 3) the number of proposed dwelling units and overall project density. TABLE B Gross Acres Net Acres DUs Allowed at GMCP Density (RLM, 3.2 du/ac) DUs Proposed and Project Density 0.93 acres 0.93 acres 2.97 dwelling units Three (3) single-family units are proposed for a total of 3.22 du/ac. Project grading will require approximately 400 cubic yards of cut and 1,500 cubic yards of fill, which results in an import of 1,100 cubic yards. To accommodate the proposed fill, a retaining wall with a maximum height of six (6) feet is proposed along the western property line. As indicated above, all walls which are currently existing around the perimeter of the property, will remain. A Planned Development Permit (PUD) is required pursuant to CMC Section 21.45.010 for airspace condominium projects in the R-1 zone where two (2) or more detached dwelling units are proposed on one lot. A Coastal Development Permit (CDP), subject to the requirements of the Mello II Segment of the Local Coastal Program, is required because the project site is located within the coastal zone. Finally, a Minor Subdivision (MS) is required to subdivide the property into three (3) airspace condominium units. PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE June 17, 2015 Page 4 III. ANALYSIS The project is subject to the following plans, ordinances and standards: A. Residential Low-Medium Density (RLM) General Plan Land Use designation; B. One-Family Residential (R-1) Zone and Planned Development Regulations (C.M.C. Chapters 21.10 and 21.45); C. Mello II Segment of the Local Coastal Program, and the Coastal Resources Protection Overlay Zone (C.M.C. Chapter 21.203); D. Inclusionary Housing (C.M.C. Chapter 21.85); E. Subdivision Ordinance (C.M.C. Title 20); and F. Growth Management Ordinance (C.M.C. Chapter 21.90) and Zone 1 Local Facilities Management Plan. The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable regulations and policies. The project’s compliance with each of the above regulations is discussed in the sections below. A. General Plan The General Plan Land Use designation for the project site is Residential Low to Medium Density (RLM). The RLM designation allows for low to medium density residential development at a range of 0 to 4 dwelling units per acre (du/ac) with a GMCP of 3.2 du/ac. The GMCP is also used for the purposes of calculating the city’s compliance with Government Code §65584. The project site has a net developable acreage of 0.93 acres, which allows for 2.97 dwelling units to be developed at the GMCP. A total of three (3) dwelling units with an overall density of 3.22 du/ac is proposed. While the proposed project falls within the allowable RLM density range of 0-4 du/ac, the proposed project is 0.03 units above the GMCP. Therefore, a total of 0.03 units are required to be withdrawn from the City’s Excess Dwelling Unit Bank (EDUB). As the proposed project’s location and density are compatible with the adjacent residential neighborhoods and the project is consistent with the General Plan (please see Table C below), the request to withdraw 0.03 units from the EDUB can be supported. TABLE C – GENERAL PLAN COMPLIANCE ELEMENT USE, CLASSIFICATION, GOAL, OBJECTIVE OR PROGRAM PROPOSED USES & IMPROVEMENTS COMPLIANCE Land Use The site is designated for Residential Medium (RLM) density (0-4 du/ac, with a GMCP of 3.2 du/ac). 2.97 dwellings units could be constructed on the site at the GMCP. Three (3) single-family dwelling units are proposed in conjunction with the project. The project’s density of 3.22 du/ac is within the RLM density range of 0-4 du/ac. The project will withdraw 0.03 dwelling units from the City’s Excess Dwelling Unit Bank. Yes PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE June 17, 2015 Page 5 TABLE C - GENERAL PLAN COMPLIANCE (CONTINUED) ELEMENT USE, CLASSIFICATION, GOAL, OBJECTIVE OR PROGRAM PROPOSED USES & IMPROVEMENTS COMPLIANCE Housing Provision of affordable housing. The project is conditioned to pay an affordable housing in- lieu fee on a per unit basis (3 units total) prior to recordation of the final map. Yes Public Safety Reduce fire hazards to an acceptable level The project site is located within a five minute response time of Fire Station No. 1 and has been designed to comply with the fire code, including provisions for an automatic sprinkler system within each dwelling unit. Yes Open Space & Conservation Minimize the environmental impacts to sensitive resources within the City. Utilize Best Management Practices for control of storm water and to protect water quality. The project will not have any environmental impacts on the previously graded and developed site that is void of sensitive habitat. The project is conditioned to conform to all NPDES requirements and has been designed to include Low Impact Design (LID) elements. Yes Yes Noise Comply with the residential exterior noise standard of 60 dB(A) CNEL and interior noise standard of 45 dB(A) CNEL. The project has been conditioned to complete a noise analysis prior to issuance of the building permits to confirm that the project meets the interior noise standard of 45 dB(A) CNEL. Given the existing perimeter walls, as well as the orientation of the units, an exterior noise analysis is not required. Yes Circulation Construct roadway improvements needed to serve proposed development. Frontage improvements along Chinquapin Avenue, including curb, gutter and sidewalk, will be required to be constructed as part of the proposed project. Yes PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE June 17, 2015 Page 6 B. One-Family Residential (R-1) Zone and Planned Development Regulations (CMC Chapters 21.10 and 21.45) The subject property is located within the One–Family Residential (R-1) zone, which allows for detached single-family residential units. As each of the three (3) units is proposed as an air-space condominium, a Planned Development Permit (PUD) is required pursuant to CMC Section 21.45.010. The Planned Development Ordinance allows for airspace condominium projects in the R-1 zone where two (2) or more detached dwelling units are proposed on one lot. The project includes a Planned Development Permit (PUD 14-05) and is compliant with all applicable requirements and development standards of the Planned Development Regulations as demonstrated in Attachments No. 4 and 5. Project compliance with all applicable requirements of City Council Policies No. 44 and 66, made pursuant to Planned Development Table D and E are also included as Attachments No. 6 and 7. C. Mello II Segment of the Local Coastal Program (CMC Chapter 21.201) and the Coastal Resources Protection Overlay Zone (CMC Chapter 21.203). The project site is located within the Mello II Segment of the Local Coastal Program, but is not within the appealable jurisdiction of the California Coastal Commission. The site is also located within and subject to the Coastal Resources Protection Overlay Zone. The project’s compliance with each of these programs and ordinances is discussed below: 1. Mello II Segment of the Certified Local Coastal Program and all applicable policies. The project is located in the Mello II Segment of the Local Coastal Program. The project site has a Local Coastal Program Land Use designation of Residential Low to Medium Density (RLM) and is zoned One- Family Residential (R-1), consistent with the City’s General Plan Land Use designation and zoning for the site. The RLM Land Use designation allows development of single-family residences at a density of 0-4 dwelling units per acre with a Growth Management Control Point (GMCP) of 3.2 dwelling units per acre. At the RM GMCP, 2.97 dwelling units would be permitted on this 0.93-acre (net developable) property. One of the primary requirements of the applicable coastal regulations pertains to the conversion of agricultural land to urban use. The project site is not identified as a “Map X - Designated Coastal Agricultural Lands” and therefore, is not required to be preserved nor is it subject to an agricultural conversion mitigation fee. The project is further consistent with the policies of the Coastal Act in that, a) the site is geologically stable; b) the project has been designed to reduce the amount of runoff off-site through the use of Low Impact Development (LID) design features and has been conditioned to implement the National Pollution Discharge Elimination System (NPDES) standards; c) the project does not preclude any recreational opportunities or shoreline access as the property is not located adjacent to any waterways or bodies of water; and d) the development does not obstruct views of the coastline as seen from public lands or public rights-of-way. 2. Coastal Resource Protection Overlay Zone The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (C.M.C. Chapter 21.203) in that the project will adhere to the City’s Master Drainage Plan, Grading Ordinance, Storm Water Ordinance, Standard Urban Storm Water Mitigation Plan (SUSMP) and Jurisdictional Urban Runoff Management Program (JURMP) to avoid increased urban run-off, pollutants and soil erosion. No development is proposed in areas of natural steep slopes (≥25% gradient) and no native vegetation is located on the subject property. In addition, the site is not located in an area prone to landslides, or susceptible to accelerated erosion, floods or liquefaction. PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE June 17, 2015 Page 7 D. Inclusionary Housing For all residential development of less than seven (7) units, the inclusionary housing requirement may be satisfied through the payment of an inclusionary housing in-lieu fee. The proposal to construct three (3) detached single-family condominium units has been conditioned to pay the applicable housing in-lieu fees for a total of two (2) units prior to final map approval. Pursuant to CMC Section 21.85.030.D(3), because the existing home is proposed to be demolished, a credit of one unit shall be applied to the project. E. Subdivision Ordinance The project includes three (3) air space condominium lots and is subject to the regulations of Chapter 20.16 of the Subdivision Ordinance. These subdivision regulations require the project to include required street dedications and improvements (streets, sewer, water, and drainage) to serve the proposed subdivision. The Land Development Engineering Division has reviewed the proposed project and has concluded that the proposed Minor Subdivision (i.e., four or few lots), as conditioned, complies with all applicable requirements of the Subdivision Map Act and the City’s Subdivision Ordinance. Frontage improvements along Chinquapin Avenue, including curb, gutter and sidewalk, will be required to be constructed as part of the proposed project. General utility and access easements will be dedicated on the final map to allow for the construction of project drainage, sewer, and water facilities. No standards variances are needed to approve the project. Given the above, the proposed subdivision would provide all necessary facilities and improvements without producing land conflicts; therefore, the project is consistent with the Subdivision Ordinance. F. Growth Management Ordinance The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of the City. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in Table “E” below. TABLE E – GROWTH MANAGEMENT COMPLIANCE STANDARD IMPACTS COMPLIANCE City Administration 10.43 sq. ft. Yes Library 5.56 sq. ft. Yes Waste Water Treatment 3 EDU Yes Parks 0.02 acre Yes Drainage 2.7 CFS / Drainage Basin “B” Yes Circulation 30 ADT Yes Fire Station No. 1 Yes Open Space N/A N/A Schools Carlsbad (E= 1.02/ M= 0.355/ HS = 0.309) Yes Sewer Collection System 3 EDU Yes Water 1,900 GPD Yes PUD 14-05/CDP 14-18/MS 14-08 – OCEAN BREEZE June 17, 2015 Page 8 The unit yield of the property at the RLM GMCP (0-4 du/ac) is 2.97 dwelling units and 3 units are proposed. The proposed project is 0.03 units above the GMCP for RLM properties. Therefore, 0.03 units will be withdrawn from the City’s Excess Dwelling Unit Bank. IV. ENVIRONMENTAL REVIEW The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption of the State CEQA Guidelines. The project is consistent with the General Plan and the Zoning Ordinance; the project site is within the City limits, is less than 5 acres in size, and is surrounded by urban uses; there is no evidence that the site has value as habitat for endangered, rare, or threatened species; approval of the project will not result in significant effects relating to traffic, noise, air quality, or water quality; and the site can be adequately served by all required utilities and public services. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project. A Notice of Exemption will be filed by the City Planner upon final project approval. ATTACHMENTS: 1. Planning Commission Resolution No. 7108 2. Location Map 3. Disclosure Statement 4. Planned Development Compliance Table C 5. Planned Development Compliance Table E 6. City Council Policy 44 Compliance Table 7. City Council Policy 66 Compliance Table 8. Correspondence in Opposition, Michelle and John Heil, 527 Chinquapin Avenue, June 9, 2015 9. Reduced Exhibits 10. Full Size Exhibits “A – EE” dated June 17, 2015 CHINQUAPI N AV LI N M A R L N HI B I S C U S C RTAMARACK AV J E F F E R S O N S T H A R B O R D R LO N G P L LAYANG LAY A N G C R AGUILA S TB A L DW I N L N C A N A R IO S T CITRUS PLSHERID A N PL PUD 14-05 / CDP 14-18 / MS 14-08Ocean Breeze SITE MAP SITE EL CAMINO R E A LLA COSTA AV ALGA RD C A R L S B A D B L Ccityof Carlsbad DISCLOSURE STATEMENT P-1(A) Development Servic·es Planning Division 1635 Faraday Avenue (760} 602-4610 www.carlsbadca.gov Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until.this information is completed·. Please print. 1. 2. APPUCANT (Not the applicant's agent) Provide the COMPLETE. LEGAL names and addresses of ALL. persons haying a · · financial interest in the application.-If the applicant includes a corporation or partnership, includ& the names, titles·, addresses of all individuals owning more than 1 0% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached If necessary.) Person ~: d·\(+{p( r CIA!> h m~n Corp/Part 6 0 'j ct...· t'\t tAIJtj? ,'VII t. t..C. Title $&lt ~t}~onbe£ Title _____ -_______ _ Address ..So.tme Address /O)Q Sar1l-. £<-fAJ &elc.v:A ~ CA I 'IJO?S' OWNER (Not the owner's agent) Provide the COMPLETE. LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership {i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF T~E SHARES, PLEASE INDICATE NON~APPLICABLE (NIA) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of'the.corporate officers. {A separate page may be attached if necessary.) Person re ·, cka \(p:{ I Cu ~ ~ tv\'Wl Corp/Part 6 0 '6 c:J, •,., ~Af; \1 ' k .L {,' Title Sole. W\'ttnbif" Title. ___________ _ Address ~W\'(. Address /OJO San I~ !iv.e.fa.. ~kYI'1 ~ch I CA, 9Jo2£ P-1(A) Page1 of 2 Revised 07/10 3. NON-PROFIT ORGANIZATION OR TRUST If any person identified pursuant to .(1} or (2) above is a nonprofit organization or a trust, list the names and addresses of ANY person serving as an officer or director of the non· profit organization or as trustee or beneficiary of the: Non Profit/Trust Non Profit/Trust.,_. --------~ Title Title _____________ _ Address. _________ _ Address. ___________ _ 4. Have you had ·more than $500 worth of business transacted with any member of City . staff, Boards, Commissions, Committees and/or Council within the past twelve (12) months? D Yes ~No If yes, please indicate person(s)~----------- NOTE: Attach additional sheets if necessary. Print or type name of owner Print or type name of applicant Print or type name of owner/applicant's agent P-1 (A) Page 2 of 2 Revised 07/10 ATTACHMENT 4 PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT C.1 Density Per the underlying General Plan designation. When two or more general plan land use designations exist within a planned development, the density may be transferred from one general plan designation to another with a general plan amendment. NA. C.2 Arterial Setbacks All dwelling units adjacent to any arterial road shown on the Circulation Element of the General Plan shall maintain the following minimum setbacks from the right-of-way: Prime Arterial 50 Feet Major Arterial 40 Feet Secondary Arterial 30 Feet Carlsbad Boulevard 20 Feet NA. Half (50%) of the required arterial setback area located closest to the arterial shall be fully landscaped to enhance the street scene and buffer homes from traffic on adjacent arterials, and:  Shall contain a minimum of one 24” box tree for every 30 lineal feet of street frontage; and  Shall be commonly owned and maintained NA. Project perimeter walls greater than 42 inches in height shall not be located in the required landscaped portion of the arterial setback, except noise attenuation walls that:  Are required by a noise study, and  Due to topography, are necessary to be placed within the required landscaped portion of the arterial setback. NA. C.3 Permitted Intrusions into Setbacks/ Building Separation Permitted intrusions into required building setbacks shall be the same as specified in Section 21.46.120 of this code. The same intrusions specified in Section 21.46.120 shall be permitted into required building separation. NA. Project is not proposing any intrusions. C.4 Streets Private Minimum right-of-way width 56 feet NA. Project is not proposing a private street. Minimum curb-to-curb width 34 feet Minimum parkway width (curb adjacent) 5.5 feet, including curb Minimum sidewalk width 5 feet (setback 6 inches from property line) Public Minimum right-of-way width 60 feet NA. Project is not proposing a public street. Minimum curb-to-curb width 34 feet Minimum parkway width (curb adjacent) 7.5 feet, including curb Minimum sidewalk width 5 feet (setback 6 inches from property line) Street Trees within parkways One-family dwellings and twin homes on small-lots A minimum of one street tree (24-inch box) per lot is required to be planted in the parkway along all streets. NA. Condominium projects Street trees shall be spaced no further apart than 30 feet on center within the parkway. NA. Tree species should be selected to create a unified image for the street, provide an effective canopy, avoid sidewalk damage and minimize water consumption. NA. PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT C.5 Drive-aisles 3 or fewer dwelling units Minimum 12 feet wide when the drive-aisle is not required for emergency vehicle access, as determined by the Fire Chief. Project complies. Access to the three (3) detached single-family condominium is proposed to be provided by a 24-foot wide private drive aisle. As the proposed drive aisle exceeds 150 feet in depth, a fire-department turn-around is also provided. If the drive-aisle is required for emergency vehicle access, it shall be a minimum of 20 feet wide. 4 or more dwelling units Minimum 20 feet wide. N/A All projects No parking shall be permitted within the minimum required width of a drive-aisle. Project complies. No parking is proposed within the minimum required width of the proposed private drive-aisle. A minimum 24-foot vehicle back-up/maneuvering area shall be provided in front of garages, carports or uncovered parking spaces (this may include driveway area, drive-aisles, and streets). Project complies. A minimum 24-foot vehicle back-up/maneuvering area is provided in front of the proposed garages and guest parking spaces. Additional width may be required for vehicle/emergency vehicle maneuvering area. NA. Parkways and/or sidewalks may be required. NA. A parkway and/or sidewalks are not required for private drive aisles. No more than 24 dwelling units shall be located along a single-entry drive-aisle. Project complies. Less than 24 dwelling units are proposed adjacent to the private drive-aisle. All drive-aisles shall be enhanced with decorative pavement. Project complies. The private drive-aisle serving the three (3) detached single- family condominium units is proposed to be enhanced with decorative stamped concrete C.6 Number of Visitor Parking Spaces Required (1) Projects with 10 units or fewer A .30 space per each unit. Project complies. The project is proposing three (3) dwelling units; therefore, a one (1) parking stall is required to be provided (3 x 0.30 = 0.9 = 1). . The applicant is proposing parking for two (2) visitor stalls as well as one (1) van accessible parking stalls. All of the parking stalls will be located outside of the 24-foot-wide drive aisle. Therefore, the project is consistent within this requirement. Projects 11 units or more A .25 space per each unit. When calculating the required number of visitor parking spaces, if the calculation results in a fractional parking space, the required number of visitor parking spaces shall always be rounded up to the nearest whole number. PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT C.7 Location of Visitor Parking On Private/ Public Streets On-street visitor parking is permitted on private/public streets, subject to the following:  The private/public street is a minimum 34-feet wide (curb-to-curb)  There are no restrictions that would prohibit on-street parking where the visitor parking is proposed  The visitor parking spaces may be located: o Along one or both sides of any private/public street(s) located within the project boundary, and o Along the abutting side and portion of any existing public/private street(s) that is contiguous to the project boundary NA. In parking bays along public/private streets within the project boundary, provided the parking bays are outside the minimum required street right-of-way width. NA. When visitor parking is provided as on-street parallel parking, not less than 24 lineal feet per space, exclusive of driveway/drive-aisle entrances and aprons, shall be provided for each parking space, except where parallel parking spaces are located immediately adjacent to driveway/drive-aisle aprons, then 20 lineal feet may be provided. NA. Within the Beach Area Overlay Zone, on-street parking shall not count toward meeting the visitor parking requirement. NA. On Drive-aisles Visitor parking must be provided in parking bays that are located outside the required minimum drive-aisle width. Project complies. The visitor parking spaces proposed are located outside of the minimum drive-aisle width. On a Driveway Outside the Beach Area Overlay Zone One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or more. NA. For projects with 10 or fewer units, all required visitor parking may be located within driveways (located in front of a unit’s garage), provided that all dwelling units in the project have driveways with a depth of 20 feet or more. NA. Within the Beach Area Overlay Zone One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or more. NA. If the streets within and/or adjacent to the project allow for on-street parking on both sides of the street, then visitor parking may be located in a driveway, subject to the following:  All required visitor parking may be located within driveways (located in front of a unit’s garage), provided that all dwelling units in the project have driveways with a depth of 20 feet or more.  If less than 100% of the driveways in a project have a depth of 20 feet or more, then a .25 visitor parking space will be credited for each driveway in a project that has a depth of 20 feet or more (calculations resulting in a fractional parking space credit shall always be rounded down to the nearest whole number). NA. All projects The minimum driveway depth required for visitor parking (20 feet or 40 feet) applies to driveways for front or side- loaded garages, and is measured from the property line, back of sidewalk, or from the edge of the drive-aisle, whichever is closest to the structure. Project complies. The visitor parking spaces proposed are located outside of the minimum drive-aisle width and allow for 24’ of back-up area. Compact Parking For projects of more than 25 units, up to 25% of visitor parking may be provided as compact spaces (8 feet by 15 feet). No overhang is permitted into any required setback area or over sidewalks less than 6 feet wide. NA. PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT For all projects within the Beach Area Overlay Zone, up to 55% of the visitor parking may be provided as compact spaces (8 feet by 15 feet). NA. Distance from unit Visitor parking spaces must be located no more than 300 feet as measured in a logical walking path from the entrance of the unit it could be considered to serve. Project complies. Visitor parking is located closer than 300 ft. C.8 Screening of Parking Areas Open parking areas should be screened from adjacent residences and public rights- of-way by either a view-obscuring wall, landscaped berm, or landscaping, except parking located within a driveway. Project complies. The proposed visitor parking is appropriately located in between Condo 1 and 2, which screens the stalls as viewed from Chinquapin Avenue. In addition, as landscaping is proposed around the perimeter of the property and screen walls are located around the perimeter as well, the visitor stalls will be adequately screened from the adjacent residential properties. C.9 Community Recreational Space (1) Community recreational space shall be provided for all projects of 11 or more dwelling units, as follows: NA. Minimum community recreational space required Project is NOT within RH general plan designation 200 square feet per unit Project IS within RH general plan designation 150 square feet per unit Projects with 11 to 25 dwelling units Community recreational space shall be provided as either (or both) passive or active recreation facilities. NA. Projects with 26 or more dwelling units Community recreational space shall be provided as both passive and active recreational facilities with a minimum of 75% of the area allocated for active facilities. NA. Projects with 50 or more dwelling units Community recreational space shall be provided as both passive and active recreational facilities for a variety of age groups (a minimum of 75% of the area allocated for active facilities). NA. For projects consisting of one-family dwellings or twin homes on small-lots, at least 25% of the community recreation space must be provided as pocket parks.  Pocket park lots must have a minimum width of 50 feet and be located at strategic locations such as street intersections (especially “T-intersections”) and where open space vistas may be achieved. NA. All projects (with 11 or more dwelling units) Community recreational space shall be located and designed so as to be functional, usable, and easily accessible from the units it is intended to serve. NA. Credit for indoor recreation facilities shall not exceed 25% of the required community recreation area. NA. Required community recreation areas shall not be located in any required front yard and may not include any streets, drive-aisles, driveways, parking areas, storage areas, slopes of 5% or greater, or walkways (except those walkways that are clearly integral to the design of the recreation area). NA. Recreation Area Parking In addition to required resident and visitor parking, recreation area parking shall be provided, as follows: 1 space for each 15 residential units, or fraction thereof, for units located more than 1,000 feet from a community recreation area. NA. The location of recreation area parking shall be subject to the same location requirements as for visitor parking, except that required recreation area parking shall not be located within a driveway(s). NA. PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT Examples of recreation facilities include, but are not limited to, the following: Active Swimming pool area Children’s playground equipment Spa Courts (tennis, racquetball, volleyball, basketball) Recreation rooms or buildings Horseshoe pits Pitch and putt Grassy play areas with a slope of less than 5% (minimum area of 5,000 square feet and a minimum dimension of 50 feet) Any other facility deemed by the City Planner to satisfy the intent of providing active recreational facilities. Passive Benches Barbecues Community gardens Grassy play areas with a slope of less than 5%. C.10 Lighting Lighting adequate for pedestrian and vehicular safety shall be provided. Project complies. Pedestrian scaled path lighting will be incorporated into the design to ensure that pedestrian and vehicular safety is addressed. C.11 Reserved C.12 Recreational Vehicle (RV) Storage (1) Required for projects with 100 or more units, or a master or specific plan with 100 or more planned development units. Exception: RV storage is not required for projects located within the RMH or RH land use designations. NA. 20 square feet per unit, not to include area required for driveways and approaches. Developments located within master plans or residential specific plans may have this requirement met by the common RV storage area provided by the master plan or residential specific plan. RV storage areas shall be designed to accommodate recreational vehicles of various sizes (i.e. motorhomes, campers, boats, personal watercraft, etc.). NA. The storage of recreational vehicles shall be prohibited in the front yard setback and on any public or private streets or any other area visible to the public. A provision containing this restriction shall be included in the covenants, conditions and restrictions for the project. All RV storage areas shall be screened from adjacent residences and public rights-of-way by a view-obscuring wall and landscaping. NA. PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT C.13 Storage Space 480 cubic feet of separate storage space per unit. Project complies. Each of the three (3) detached single-family condominium units includes a two-car garage (20 ft. x 20 ft. minimum interior space), which satisfies the storage space requirement. If all storage for each unit is located in one area, the space may be reduced to 392 cubic feet. Required storage space shall be separately enclosed for each unit and be conveniently accessible to the outdoors. Project complies. Required storage space may be designed as an enlargement of a covered parking structure provided it does not extend into the area of the required parking stall, and does not impede the ability to utilize the parking stall (for vehicle parking). Project complies. A garage (12’x20’ one-car, 20’x20’ two-car, or larger) satisfies the required storage space per unit. Project complies. This requirement is in addition to closets and other indoor storage areas. Project complies. (1) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code). ATTACHMENT 5 PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT E.1 Livable Neighborhood Policy Must comply with city council Policy 66, Principles for the Development of Livable Neighborhoods. SEE SEPARATE COMPLIANCE CHART E.2 Architectural Requirements One-family and two-family dwellings Must comply with city council Policy 44, Neighborhood Architectural Design Guidelines SEE SEPARATE COMPLIANCE CHART Multiple-family dwellings There shall be at least three separate building planes on all building elevations. The minimum offset in planes shall be 18 inches and shall include, but not be limited to, building walls, windows, and roofs. NA. The project proposes detached one- family condominium units. All building elevations shall incorporate a minimum of four complimentary design elements, including but not limited to:  A variety of roof planes;  Windows and doors recessed a minimum of 2 inches;  Decorative window or door frames;  Exposed roof rafter tails;  Dormers;  Columns;  Arched elements;  Varied window shapes;  Exterior wood elements;  Accent materials such as brick, stone, shingles, wood, or siding;  Knee braces; and  Towers. NA. The project proposes detached one- family condominium units. E.3 Maximum Coverage 60% of total project net developable acreage. Project complies. Total building coverage for the three (3) proposed one- family detached condominium units is 35.32% (i.e., less than 60%). E.4 Maximum Building Height Same as required by the underlying zone, and not to exceed three stories (1)(7) Project complies. The underlying zoning designation is R-1, One-Family Residential. Pursuant to the R-1 zone, the building height in the R-1 zone shall not exceed 30 ft. with a 3:12 pitched roof or 24 ft. for less than a 3:12 pitched roof. Condo 1 proposes a building height of 25’-2” with a 4:12 pitched roof; Condo 2 proposes a building height of 25’-6” with a 5:12 pitched roof; and Condo 3 proposes a building height of 24’-3” with a 4:12 pitched roof. Projects within the RH general plan designation (1)(7) 40 feet, if roof pitch is 3:12 or greater NA. Project site is designated RLM. 35 feet, if roof pitch is less than 3:12 Building height shall not exceed three stories PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT E.5 Minimum Building Setbacks From a private or public street(2)(3) Residential structure 10 feet Project complies. Proposed Condo 1 is setback 28 feet from Chinquapin Avenue. None of the garages propose a direct entry off of Chinquapin Avenue. Direct entry garage 20 feet From a drive- aisle(4) Residential structure (except as specified below) 5 feet, fully landscaped (walkways providing access to dwelling entryways may be located within required landscaped area) Project complies. The three (3) proposed detached one-family condominium units, including the attached two-car garages, are proposed to be setback five (5) feet from the edge of the drive aisle. Where walkways are not proposed, landscaping is provided. Residential structure –directly above a garage 0 feet when projecting over the front of a garage. Project complies. No portion of the second floor living space is projecting over the front of the garage. Garage 3 feet Project complies. The three (3) attached garages are setback five (5) feet from the drive aisle. Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener. Project complies. The project plans include a note indicating that the garages are equipped will be equipped with automatic openers. Projects of 25 units or less within the RMH and RH general plan designations 0 feet (residential structure and garage) NA. Project site is designated RLM. Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener. NA. Project site is designated RLM. Balconies/decks (unenclosed and uncovered) 0 feet NA. No useable balconies are proposed. May cantilever over a drive-aisle, provided the balcony/deck complies with all other applicable requirements, such as:  Setbacks from property lines  Building separation  Fire and Engineering Department requirements From the perimeter property lines of the project site (not adjacent to a public/private street) The building setback from an interior side or rear perimeter property line shall be the same as required by the underlying zone for an interior side or rear yard setback. Project complies. The underlying zoning designation is R-1, One-Family Residential. The project is designed to comply with the requisite 10 ft. interior side yard and 20 ft. rear yard setback consistent with Sections 21.10.070 and 21.10.080 of the Carlsbad Municipal Code. E.6 Minimum Building Separation 10 feet Project complies. The project proposes a building separation ≥10 ft, including the proposed accessory structures (i.e., gazebo and clubhouse). E.7 Resident Parking (6) All dwelling types If a project is located within the RH general plan designation, resident parking shall be provided as specified below, and may also be provided as follows:  25% of the units in the project may include a tandem two-car garage (minimum 12 feet x 40 feet).  Calculations for this provision resulting in a fractional unit may be rounded up to the next whole number. NA. Project site is designated RLM. PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT One-family and two- family dwellings 2 spaces per unit, provided as either:  a two-car garage (minimum 20 feet x 20 feet), or  2 separate one-car garages (minimum 12 feet x 20 feet each)  In the R-W Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered space (5) Project complies. Each of the three (3) one-family condominium units provides a two (2) car garage with a minimum interior dimension of 20 ft. by 20 ft. Multiple- family dwellings Studio and one- bedroom units 1.5 spaces per unit, 1 of which must be covered (5) NA. Project proposes detached one- family condominiums, which include attached two-car garages. When calculating the required number of parking spaces, if the calculation results in a fractional parking space, the required number of parking spaces shall always be rounded up to the nearest whole number. Units with two or more bedrooms 2 spaces per unit, provided as either:  a one-car garage (12 feet x 20 feet) and 1 covered or uncovered space; or (5)  a two-car garage (minimum 20 feet x 20 feet), or  2 separate one-car garages (minimum 12 feet x 20 feet each)  In the R-W Zone and the Beach Area Overlay Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered space (5) NA. Project proposes detached one- family condominiums, which include attached two-car garages. Required parking may be provided within an enclosed parking garage with multiple, open parking spaces, subject to the following:  Each parking space shall maintain a standard stall size of 8.5 feet by 20 feet, exclusive of supporting columns; and  A backup distance of 24 feet shall be maintained in addition to a minimum 5 feet turning bump-out located at the end of any stall series. NA. Project proposes detached one- family condominiums, which include attached two-car garages. Required resident parking spaces shall be located no more than 150 feet as measured in a logical walking path from the entrance of the units it could be considered to serve. NA. Project proposes detached one- family condominiums, which include attached two-car garages. PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT E.8 Private Recreational Space One-family, two-family, and multiple- family dwellings Required private recreational space shall be designed so as to be functional, usable, and easily accessible from the dwelling it is intended to serve. Project complies. Private recreational space, as required below, is designed to be functional, usable and easily accessible from the dwelling units it is intended to serve. Required private recreational space shall be located adjacent to the unit the area is intended to serve. Project complies. Private recreational space, as required below, is located adjacent to the units it is intended to serve. Required private recreational space shall not be located within any required front yard setback area, and may not include any driveways, parking areas, storage areas, or common walkways. Project complies. Private recreational space, as required below, is not located within any required front yard setback area; and does not include any driveways, parking areas, storage areas or common walkways. One-family and two- family dwellings Minimum total area per unit Projects not within the RMH or RH general plan designations 400 square feet Project complies. A minimum of 400 SF of private recreation area is proposed for each of the units. In addition, a 1,547 SF common recreation clubhouse is proposed for the use of the residents. Projects within the RMH or RH general plan designations 200 square feet NA. Project site is designated RLM. May consist of more than one recreational space. Project complies. In addition to the private recreation space, a common recreation clubhouse is proposed for the use of the residents. May be provided at ground level and/or as a deck/balcony on a second/third floor or roof. Project complies. The recreation space is located at the ground level. If provided at ground level Minimum dimension Not within the RMH or RH general plan designations 15 feet Project complies. The proposed recreation areas have a minimum dimension of 15 feet. Within the RMH or RH general plan designations 10 feet NA. Project site is designated RLM. Shall not have a slope gradient greater than 5%. Project complies. The proposed private recreation areas and the communal clubhouse are located in areas which do not have slope gradients in excess of 5%. Attached solid patio covers and decks/balconies may project into a required private recreational space, subject to the following:  The depth of the projection shall not exceed 6 feet (measured from the wall of the dwelling that is contiguous to the patio/deck/balcony). The length of the projection shall not be limited, except as required by any setback or lot coverage standards. Project complies. While not being used to qualify for the private recreation area, a front porch facing Chinquapin Avenue is proposed for Condo 1. Open or lattice-top patio covers may be located within the required private recreation space (provided the patio cover complies with all applicable standards, including the required setbacks). Project complies. The gazebo proposed at the northeast corner of the property complies with the setbacks as well as the building separation requirements. If provided above ground Minimum dimension 6 feet NA. No private decks or balconies are proposed. PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT level as a deck/balcony or roof deck Minimum area 60 square feet Multiple-family dwellings Minimum total area per unit (patio, porch, or balcony) 60 square feet NA. Project proposes detached one- family condominiums. Minimum dimension of patio, porch or balcony 6 feet NA. Project proposes detached one- family condominiums. Projects of 11 or more units that are within the RH general plan designation may opt to provide an additional 75 square feet of community recreation space per unit (subject to the standards specified in Table C of this Chapter), in lieu of providing the per unit private recreational space specified above. NA. Project proposes detached one- family condominiums. (1) If a project is located within the Beach Area Overlay Zone, building height shall be subject to the requirements of Chapter 21.82 of this code. (2) See Table C in Section 21.45.060 for required setbacks from an arterial street. (3) Building setbacks shall be measured from the outside edge of the required street right-of-way width, whichever is closest to the building. (4) Building setbacks shall be measured from one of the following (whichever is closest to the building): a) the outside edge of the required drive- aisle width; b) the back of sidewalk; or c) the nearest side of a parking bay located contiguous to a drive-aisle (excluding parking located in a driveway in front of a unit’s garage). (5) Any uncovered required parking space in the R-W zone may be located within a required front yard setback and may be tandem. (6) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code). (7) Protrusions above the height limit shall be allowed pursuant to Section 21.46.020 of this code. Such protrusions include protective barriers for balconies and roof decks. ATTACHMENT 6 CITY COUNCIL POLICY NO. 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES Architectural Guideline Compliance Comments Floor Plans and Elevations 1 All residential projects shall be required to have a minimum number of different floor plans, different front and corresponding matching rear elevations with different color schemes as identified below: 2-4 dwelling units shall provide 1 floor plan and 2 different elevations. 5-12 dwelling units shall provide 2 different floor plans and 2 different elevations. 13-20 dwelling units shall provide 2 different floor plans and 3 different elevations. 21+ dwelling units shall provide 3 different floor plans and 3 different elevations. Project complies. Project proposes one (1) floor plan and three (3) different elevations. Each unit incorporates a different architectural style and color palette. In addition, the materials utilized on the front elevation are carried around to the rear elevations. 2 Every house should have a coherent architectural style. All elevations of a house, including front, side and rear, should have the same design integrity of forms, details and materials. Project complies. Condo 1 proposes a Craftsman architectural style; Condo 2 proposes a Spanish/Mediterranean architectural style; and Condo 3 proposes a Cape Cod architectural style. Each elevation incorporates detailing, materials and a color palette which supports the style of architecture proposed. 3 In addition to the previous requirements, design details should reinforce and enhance the architectural form and style of every house and differ from other elevations of the same floor plan. A minimum of 4 complimentary design details, including but not limited to those listed below, shall be incorporated into each of the front, rear and street side building façade(s) of the house. Design Details Project complies. A minimum of four (4) complimentary design details are used to reinforce and enhance the architectural form and style of the proposed homes. Balconies Decorative eaves and fascia Exposed roof rafter tails Arched elements Towers Knee braces Dormers Columns Exterior wood elements Accent materials (i.e.; brick, stone, shingles, wood or siding) 4 Floor plans in a project shall exhibit a variety of roof ridges and roof heights within a neighborhood. Project complies. Condos 1-3 exhibit a variety of roof ridges and heights. 5-8 NA to projects of 2-4 homes. CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES CONTINUED Architectural Guideline Compliance Comments Single Story Requirements 9 The remaining total number of homes shall comply with one of the following guidelines: The home shall have a single-story building edge with a depth of not less than 8 feet and shall run the length of the building along one side except for tower elements. The roof covering the single- story element shall incorporate a separate roof plane and shall be substantially lower than the roof for the two-story element. Porches and porte-cochere elements shall qualify as a single-story edge. Houses with courtyards that are a minimum of 15 feet wide located along the side of the house and setback a minimum of 15 feet from the property line are not required to have a single-story building edge. The home shall have a single-story building edge with a depth of not less than 5 feet and shall run the length of the building along one side. The roof of the single-story element shall be substantially lower than the roof for the two-story element of the building. The home shall have a single-story building edge with a depth of not less than 3 feet for 40% of the perimeter of the building. Project complies. Each plan type provides a significant extent of single-story building edge with a minimum depth of no less than eight (8) ft. along each side. Multiple Building Planes 10 For at least 66% of the homes in a project, there shall be at least 3 separate building planes on street side elevations of lots with 45 feet of street frontage or less and 4 separate building planes on street side elevations of lots with a street frontage greater than 45 feet. Balconies and covered porches qualify as a building plane. The minimum offset in planes shall be 18 inches and shall include, but not be limited to, building walls, windows, porches and roofs. The minimum depth between the faces of the forward-most plane and the rear plane on the front elevation shall be 10 feet. A plane must be a minimum of 30 sq. ft. to receive credit under this section. Project complies. 66% of the 3 units = 1.98 units or 2 units when rounded up. All three (3) units proposed include three (3) or more building planes on the front elevations facing the private motor court area and Chinquapin Avenue (Condo 1). Each plane complies with the minimum 18-inch offset and meets the minimum 30 sq. ft. requirement. Lastly, the minimum 10 ft. depth between the forward-most and rear plane on the front elevation is achieved. CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES CONTINUED Architectural Guideline Compliance Comments Multiple Building Planes 11 Rear elevations shall adhere to the same criteria outlined in Number 10 above for front elevations except that the minimum depth between front and back planes on the rear elevation shall be 4 feet. Rear balconies qualify as a building plane. Project complies. 66% of the 3 units = 1.98 units or 2 units when rounded up. All three (3) units proposed include three (3) or more building planes on the rear elevations. Each plane complies with the minimum 18- inch offset and meets the minimum 30 sq. ft. requirement. Furthermore, the minimum 4 ft. depth between the forward-most and rear plane on the rear elevation is achieved. Windows/Doors 13 At least 66% of exterior openings (door/windows) on every home in the project shall be recessed or projected a minimum of 2 inches and shall be constructed with wood, vinyl or colored aluminum window frames (no mill finishes). Project complies. All of the exterior openings are either recessed or inset a minimum of two (2) inches or trimmed with a minimum 2-inch thick foam trim. Window are constructed of vinyl window frames with decorative mullions. 14 Windows shall reinforce and enhance the architectural form and style of the house through, the use of signature windows and varied window shapes and sizes. Project complies. The windows proposed for each unit complement the different architectural styles. Front Porches 15 Fifty percent (50%) of the homes shall be designed with a covered front porch, open courtyard, or balcony (each with a minimum depth of 6 feet and a minimum area of 60 square feet) located at the front of the dwelling. The minimum depth for a covered front porch shall be measured from the front facade of the home to the inside of any supporting porch posts. The front and sides of porches shall be open except for required and/or ornamental guardrails. A variety of roof elements shall be provided over porches. Porches may not be converted to living space. Project complies. All of the units are designed with a front porch with a minimum depth of 6 feet and a minimum area of 60 square feet as measured from the front facade of the home to the inside of the supporting porch posts or wall. CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES CONTINUED Architectural Guideline Compliance Comments Front Entries 16 Seventy-five percent (75%) of the homes must have a front entry to the home that is clearly visible from the street. Walkways from the front door to the street are encouraged. Project complies. All units have a front entry that is clearly visible from the drive-aisle. Chimneys 17 Chimneys and chimney caps shall be in scale with the size of the home. No more than 2 chimneys shall be allowed for homes on lots in planned developments having an area less than 7,500 square feet. Project complies. The proposed chimneys are in scale with each of the units. Garage Doors 18 Garage doors for 3 or 4 cars in a row that directly face the street must have a minimum of an 18” plane change between the garage doors after the 2 car garage door. NA. None of the proposed units include garages that can accommodate more than two cars. Note #1: Fractional units of .5 or greater shall be rounded up to the next whole number and located in a manner to achieve the best project design as determined by the project planner. When a percentage of units are described in the guidelines, the intent is to have that percentage spread throughout the entire project. ATTACHMENT 7 CITY COUNCIL POLICY NO. 66 – LIVABLE NEIGHBORHOODS Principle Compliance Comments 1 Building Facades, Front Entries, Porches Facades create interest and character and should be varied and articulated to provide visual interest to pedestrians. Clearly identifiable front doors and porches enhance the street scene and create opportunities for greater social interaction within the neighborhood. Building entries and windows should face the street. Front porches, bay windows, courtyards and balconies are encouraged. Project complies. The proposed building facades create visual interest and character, which are varied and articulated to promote visual interest to pedestrians and neighboring homes. The entrances to Condos 1, 2 and 3 face the interior motor court area. The front façade for Condo 1 (facing Chinquapin Avenue) has been enhanced with a porch and a variety of materials, which are inviting and help to provide an opportunity for social interaction and visual interest within the neighborhood. 2 Garages Homes should be designed to feature the residence as the prominent part of the structure in relation to the street. A variety of garage configurations should be used to improve the street scene. This may include tandem garages, side-loaded garages, front-loaded garages, alley- loaded garages and recessed garages. Project complies. The unique constraints of this small infill site limit the project’s ability to produce a variety of garage configurations as envisioned under this guideline (i.e., side- loaded and/or alley loaded garages). In addition, the narrowness and small size of this infill project site, combined with the implementation of the Planned Development regulations, including the minimum setback and open space requirements, further impede the design and development of tandem or deeply recessed rear yard garage type configurations. To ensure an improved street scene along the drive aisle, the area will be enhanced with stamped concrete, as well as landscaping on both sides of the drive aisle. Further, the garages will be screened from view from the adjacent residences (at the first floor) by existing walls, as well as from the proposed landscaping. The north elevation of Condo 1, which faces Chinquapin Avenue, has been enhanced with a porch and a variety of materials which complement the Craftsman style. CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS Principle Compliance Comments 3 Street Design An interconnected, modified (grid) street pattern should be incorporated into project designs when there are no topographic or environmental constraints. Interconnected streets provide pedestrians and automobiles many alternative routes to follow, disperse traffic and reduce the volume of cars on any one street in the neighborhood. Streets should be designed to provide both vehicular and pedestrian connectivity by minimizing the use of cul-de-sacs. The street network should also be designed to create a safer, more comfortable pedestrian and bicycling environment. Local residential streets should have travel and parking lanes, be sufficiently narrow to slow traffic, provide adequate access for emergency and service vehicles and emergency evacuation routes for residents and include parkways with trees to form a pleasing canopy over the street. Local residential streets are the public open space in which children often play and around which neighborhoods interact. Within this context, vehicular movement should be additionally influenced through the use of City-accepted designs for traffic calming measures. NA. The unique constraints of this small infill site limit the project’s ability to provide an interconnected, modified (grid) street pattern. 4 Parkways Street trees should be planted in the parkways along all streets. Tree species should be selected to create a unified image for the street, provide an effective canopy, avoid sidewalk damage and minimize water consumption. Project complies. The project does not propose any public or private streets. However, a private drive aisle is proposed leading back to the three (3) single-family residential condominium units. The drive-aisle is lined with landscaping, including trees, shrubs and ground cover on both sides, which creates a unified image for the drive. 5 Pedestrian Walkways Pedestrian walkways should be located along or visible from all streets. Walkways (sidewalks or trails) should provide clear, comfortable and direct access to neighborhood schools, parks/plazas and transit stops. Primary pedestrian routes should be bordered by residential fronts, parks or plazas. Where street connections are not feasible (at the end of cul-de-sacs), pedestrian paths should also be provided. Project complies. The proposed project includes frontage improvements along Chinquapin Avenue, including a parkway and a public sidewalk, which provides access to schools, parks and public transportation. Internal to the project site, pedestrian walkways are provided to the public sidewalk, in front of the units, as well as around the rear perimeter of the property to allow for open access to the gazebo and clubhouse. CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS Principle Compliance Comments 6 Centralized Community Recreation Areas Park or plazas, which serve as neighborhood meeting places and as recreational activity centers should be incorporated into all planned unit developments. As frequently as possible, these parks/plazas should be designed for both active and passive uses for residents of all ages and should be centrally located within the project. Parks and plazas should be not be sited on residual parcels, used as buffers from surrounding developments or to separate buildings from streets. Project complies. Although community recreational space is required for projects consisting of 11 or more units, the proposed three-unit project has been designed to include a 1,547 square recreation clubhouse, as well as a gazebo. These accessory structures will allow for both active and passive use for the residents of the community. PLOT: 11/24/14 @ 08:54608 CHINQUAPIN AVEOCEAN BREEZECARLSBAD, CASHEETSHEET TITLE:REVISIONSSML2013-549.01AS NOTEDGS MMEDIA3-9-15CITY COMMENTS1CITY COMMENTS2OCEAN BREEZEAPN 206-042-28-00VICINITY MAP- 3 OPEN AIR CONDOSTENTATIVE MAP NO.C-1.0TENTATIVEPARCEL MAPGENERAL NOTESSITE DRAINAGELEGAL DESCRIPTIONLEGENDCONSTRUCTION ITEMSDEMOLITION ITEMSBENCHMARKBASIS OF BEARINGSSURVEYORASSESSOR'S PARCEL NUMBERDEMOLITION NOTESITE CHINQUAPIN AVECLUBHOUSECONDO3CONDO2CONDO1RAMPSLOPEDN12' RAMP UP8%DNRAMP8%8%SLOPERAMPRAMPRAMPUP 5%UP 5%UP 5%RAMPUP 5%RAMPFHFHFIREEASEMENTSSSSSSSSSSSSSSSSD SD SD SD SD SD SD WWWWWWWWWWWWWWWWWWWWWWWW%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%PPPPPPPPPP555555555555555%5%5%5%5%5%5%%%%UUUUUUUUUUUUUUUUUUUUUUUUUPUPPPPFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFHFFFFFFFHHFFFFHHHHHHHFFHHHHHHHHHHHHFFFFHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHAAAPLOT: 04/30/14 @ 14:40608 CHINQUAPIN AVEOCEAN BREEZECARLSBAD, CAFILE NAME: C:\Users\mahak_000\appdata\local\temp\AcPublish_58380\CP-2.dwg LAYOUT NAME: L1.1 PLOTTED: Friday, May 22, 2015 - 4:14pmSHEETSHEET TITLE:REVISIONSMB / DM2013-549.01AS NOTEDMLASD05/26/20151 12/01/14 CITY COMMENTSAPPLICATION #'S PUD / 14-05 / CDP 14-18 / MS 14-08-OCEANBREEZE2 15/02/19 CITY COMMENTS3 15/05/26 CITY COMMENTSLEGENDSTREET TREES AND OTHER TREES SHALL BE SPACED1. 8 FEET FROM TRANSFORMERS, CABLE AND PULL BOXES.2. 5 FEET FROM MAIL BOXES.3. 5 FEET FROM FIRE HYDRANTS.4. 10 FEET FROM CENTER LINE OF ALL UTILITY LINES (WITHOUT EASEMENT) (SEWER, WATER,STORM DRAINS, DOUBLE CHECK DETECTORS, AIR RELIEF VALVES AND GAS).5. 10 FEET FROM EASEMENT BOUNDARIES (SEWER, WATER, STORM DRAINS, ACCESS OR OTHERUTILITIES)6. 10 FEET FROM DRIVEWAYS (UNLESS A LINE OF SIGHT IS DETERMINED BY THE TRAFFIC DIVISIONTO BE OTHERWISE).7. 10 FEET FROM TRAFFIC AND DIRECTIONAL SIGNS.8. 15 FEET (MINIMUM) FROM STREETLIGHTS, OTHER UTILITY POLES, (DETERMINED BYSPECIFICATIONS).9. STREET TREES SHALL BE PLANTED 3' OUTSIDE RIGHT OF WAY IF THE RIGHT OF WAY DOES NOTALLOW SPACE, SUBJECT TO THE CITY ENGINEER'S APPROVAL.10. LINE OF SIGHT AT ARTERIALS, COLLECTOR AND LOCAL STREETS SHALL BE REVIEWED ANDDETERMINED BY TRAFFIC ENGINEER. A MINIMUM OF 25' FROM STREET INTERSECTION OR ASAPPROVED BY THE TRAFFIC ENGINEER.11. MINIMUM 15' STREETLIGHT AND STOP SIGN OR CLEARANCE DETERMINED BY SPECIFICATIONS.12. SCREEN ALL UTILITIES ACCORDING TO SPECIFIC AGENCY REQUIREMENTS.THE CONCEPTUAL NATURE AND SCALE OF THIS PLAN SET IS DIFFICULT TO REPRESENT PROPOSEDPLACEMENTS OF PLANT MATERIAL ACCURATELY AS NEEDED FOR COMPLETE CITY REVIEW.THECITY RESERVES THE RIGHT TO REQUEST DIFFERENT PLANT MATERIAL ON THE FUTURE LANDSCAPEIMPROVEMENT PLANS (WORKING DRAWINGS) ASSOCIATED WITH THIS CLP DUE TO MISSED ORUNFORESEEABLE ITEMS SUCH AS NOT LIMITED TO: DISTANCE TO HARDSCAPE, LOCATION OFEASEMENTS, DISTANCE TO UTILITIES, INCOMPATIBLE TREE CHARACTERISTICS FOR A PROPOSEDLOCATION, ETC.1. NEW SITE CONCRETE WALK, NATURAL GRAY BROOM FINISH, SCORING PATTERN ASSHOWN2. PROPOSED SIDEWALK3. PROPERTY LINE4. PRIVATE DRIVEWAY - NEW STAMPED CONCRETE PAVING, SCORING PATTERN AS SHOWN5. NEW SPLIT FACE BLOCK WALL WITH WROUGHT IRON FENCE. (A TOTAL OF 6' HEIGHT) SEEDETAIL A.6. PROPOSED PATIO7. PROPOSED LINE OF SIGHT. NO PLANT MATERIAL IN THIS AREA TO EXCEED 30" IN HEIGHT.8. PROPOSED GATEWAY PER ARCH.9. PROPOSED GAZEBO PER ARCH.10. CITRUS ORCHARD11. OUTDOOR SEATING FOR CLUBHOUSE12. PROPOSED TRASH ENCLOSURE PER ARCH.13. PROPOSED FOUNTAIN, DETAIL B14. PROPOSED DRIVEWAY15. PROPOSED ENHANCED CONCRETE PAVING16. PROPOSED TWO-WAY WROUGHT IRON GATE17. PROPOSED LOCATION FOR FIRE HYDRANT\18. EXISTING WATER METER TO BE SALVAGED AND REUSED FOR FOUNTAIN WATER19. NEW ENHANCED PAVING, INTEGRAL COLOR ACID ETCH FINISH, SCORING PATTERN ASSHOWN20. NEW WATER METER ASSEMBLY FOR IRRIGATION. TO BE REPLACED WITH RECYCLEDWATER UPON EXTENSION OF THE RECYCLED WATER MAIN BY THE CITY.21. NEW CONTECH FILTERRA BIOFILTRATION CURB INLETNOTE: PLANTS AROUND THE ENTRANCES AND BUILDING SHALL BE OF 5-GALLON SIZE CONTAINERS. NOR T H GRAPHIC SCALE1 INCH = 20 FT.703 16th Street, Suite 100tel (619)296-3150 fax (619) 501-7725www.mlasd.comMcCullough Landscape Architecture, inc.San Diego, California 92101DAVID W.M CULLOUGHOLIC. #4048AEXP. 12-31-16S TTAEGIRERETSEDLANI LFACFIROHCPSDNACERA ECTIT c01-19-2015DATEAN IRRIGATION SYSTEM SHALL BE PROVIDED AS REQUIRED FOR THE PROPERIRRIGATION, DEVELOPMENT AND MAINTENANCE OF THE VEGETATION. THE DESIGN OFTHE SYSTEM SHALL PROVIDE ADEQUATE SUPPORT OF THE VEGETATION SELECTED.4.3.2.WEST EXPOSURES.EVAPOTRANSPIRATION FROM THE ROOT ZONES.PLANTER BEDS WILL BE MULCHED TO RETAIN SOIL MOISTURE AND REDUCE COVERAGE AND TO PROVIDE FOR MAXIMUM MOISTURE RETENTION AND PERCOLATION.SOIL WILL BE AMENDED AND PREPARED TO PROVIDE HEALTHY PLANT GROWTH ANDPLANT MATERIAL WILL BE SPECIFIED IN CONSIDERATION OF NORTH, SOUTH, EAST, ANDIN RESPONSE TO ORIENTATION AND EXPOSURE.IRRIGATION VALVES SHALL BE SEGREGATED TO ALLOW FOR THE SYSTEM OPERATIONSYSTEMS MAY BE EMPLOYED WHERE CONSIDERED TO BE EFFECTIVE AND FEASIBLE.SPRAY EMITTERS AND CONVENTIONAL LOW ANGLE SPRAY HEADS. DRIP IRRIGATION1. THE IRRIGATION SYSTEM WILL BE AUTOMATIC AND WILL INCORPORATE LOW VOLUMECITY OF CARLSBAD'S AVAILABLE WATER SUPPLY:FOLLOWING MEASURES WILL BE UNDERTAKEN TO REDUCE THIS PROJECT'S DEMAND ON THEIN RECOGNITION OF WATER AS A LIMITED RESOURCE IN SOUTHERN CALIFORNIA, THEWATER CONSERVATION STATEMENTAN IRRIGATION SYSTEM SHALL BE PROVIDED AS REQUIRED FOR THE PROPERIRRIGATION, DEVELOPMENT AND MAINTENANCE OF THE VEGETATION. THE DESIGN OFTHE SYSTEM SHALL PROVIDE ADEQUATE SUPPORT OF THE VEGETATION SELECTED.5.LANDSCAPE IMPROVEMENT PLAN SET AND INSTALLATION ARE REQUIRED TO IMPLEMENTAPPROVED FIRE DEPARTMENT REGULATIONS, CODES, AND STANDARDS AT THE TIME OF PROJECTAPPROVAL.FIRE NOTEMAINTENANCE RESPONSIBILITY UTILITY SCREENINGPLANT MATERIAL NEAR SEWER LINESALL REQUIRED LANDSCAPE AREAS SHALL BE MAINTAINED BY THE HOME OWNERS ASSOCIATION. THELANDSCAPE AREAS SHALL BE MAINTAINED IN A FREE OF DEBRIS AND LITTER AND ALL PLANT MATERIALSHALL BE MAINTAINED IN A HEALTHY GROWING CONDITION. DISEASED OR DEAD PLANT MATERIAL SHALLBE SATISFACTORILY TREATED OR REPLACED PER THE CONDITIONS OF THIS PERMIT.ALL WATER, SEWER, AND GAS UTILITIES SHALL BE EFFECTIVELY SCREENED WITH PLANT MATERIAL ATTHE TIME OF PLANT INSTALLATION.NO TREE OR SHRUB EXCEEDING 3' IN HEIGHT SHALL BE PLANTED WITHIN 10' OF ANY PUBLIC SEWERFACILITIES.MULCHING NOTEGENERAL NOTEA. FINAL LANDSCAPE PLANS SHALL ACCURATELY SHOW PLACEMENT OF TREES, SHRUBS, AND GROUNDCOVERS.B. LANDSCAPE ARCHITECT SHALL BE AWARE OF UTILITY, SEWER, STORM DRAIN EASEMENT AND PLACEPLANTING LOCATIONS ACCORDINGLY TO MEET CITY OF CARLSBAD REQUIREMENTS.C. ALL REQUIRED LANDSCAPE AREAS SHALL BE MAINTAINED BY HOME OWNERS ASSOCIATION (INCLUDINGPUBLIC RIGHT OF WAY). THE LANDSCAPE AREAS SHALL BE MAINTAINED PER CITY OF CARLSBADREQUIREMENTS.ALL REQUIRED PLANTING AREAS SHALL BE COVERED WITH MULCH TO A MINIMUM DEPTH OF 3 INCHES,EXCLUDING SLOPES REQUIRING REVEGETATION. ALL EXPOSED SOIL AREAS WITHOUT VEGETATION SHALLALSO BE MULCHED TO THIS MINIMUM DEPTH.PLANTING NOTEA. THE SELECTION OF PLANT MATERIAL IS BASED ON CULTURAL, AESTHETIC, AND MAINTENANCECONSIDERATIONS.B. ALL PLANTING AREAS SHALL BE PREPARED WITH APPROPRIATE SOIL AMENDMENTS,FERTILIZERS, AND APPROPRIATE SUPPLEMENTS BASED UPON A SOILS REPORT FROM ANAGRICULTURAL SUITABILITY SOIL SAMPLE TAKEN FROM THE SITE.C. GROUND COVERS OR BARK MULCH SHALL FILL IN BETWEEN THE SHRUBS TO SHIELD THE SOILFROM THE SUN, EVAPOTRANSPIRATION AND RUN-OFF.D. ALL THE FLOWER AND SHRUB BEDS SHALL BE MULCHED TO A 3" DEPTH TO HELP CONSERVEWATER, LOWER THE SOIL TEMPERATURE AND REDUCE WEED GROWTH.E. THE SHRUBS SHALL BE ALLOWED TO GROW IN THEIR NATURAL FORMS.F. ALL LANDSCAPE IMPROVEMENTS SHALL FOLLOW THE CITY OF CARLSBAD GUIDELINES.G. TO INSTALL TRAILING-TYPE PLANTS CLOSEST TO THE TOP OF THE RETAINING WALL TOEVENTUALLY CASCADE OVER THE WALL WHERE APPLICABLE.H. ALL PLANTING AREAS TO SLOPE 2% AWAY FROM BUILDING AND TERMINATING INTO APPROVEDDRAINAGE SYSTEM (RETENTION BASINS OR AREA DRAINS).IRRIGATION NOTEA. IRRIGATION SYSTEMS SHALL BE DESIGNED TO USE RECLAIMED WATER, BUT SHALL BECONNECTED TO THE POTABLE WATER MAIN UNTIL RECLAIMED WATER MAIN IS PROVIDED.B. AN AUTOMATIC IRRIGATION SYSTEM SHALL BE INSTALLED TO PROVIDE COVERAGE FOR ALLPLANTING AREAS SHOWN ON THE PLAN.C. LOW VOLUME EQUIPMENT SHALL PROVIDE SUFFICIENT WATER FOR PLANT GROWTH WITH AMINIMUM WATER LOSS DUE TO WATER RUN-OFF. LOW-VOLUME IRRIGATION WILL BE INSTALLEDIN ALL PLANTING AREAS WITHIN 24" OF ANY IMPERMEABLE SURFACES.D. IRRIGATION SYSTEMS SHALL USE HIGH QUALITY, AUTOMATIC CONTROL VALVES,CONTROLLERS AND OTHER NECESSARY IRRIGATION EQUIPMENT.E. ALL COMPONENTS SHALL BE OF NON-CORROSIVE MATERIAL.F. ALL DRIP SYSTEMS SHALL BE ADEQUATELY FILTERED AND REGULATED PER THEMANUFACTURER'S RECOMMENDED DESIGN PARAMETERS.G. ALL IRRIGATION IMPROVEMENTS SHALL FOLLOW THE CITY OF CARLSBAD GUIDELINES ANDWATER CONSERVATION ORDINANCE.6'-0"2'-0"LEGEND:3'-0"3"4112"7653N.T.S.AFENCE DETAIL498121153316141414101111237715131717“I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THECITY OF CARLSBAD’S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVEPREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL ANDAGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFYTHAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER."LANDSCAPE ARCHITECT: DATE: 07/28/2014CONCEPTUAL LANDSCAPE PLAN201354901L01.1L1.1GABCEFDIHJKLNMOPQSYMBOL BOTANICAL NAME/COMMON NAME CALIPER SIZE REMARKEXISTING TREE LEGENDARAUCARIA HETEROPHYLLA / NORFOLK ISLAND PINEJUGLANS CALIFORNICA / CALIFORNIA BLACK WALNUTSYAGRUS ROMANZOFFIANA / QUEEN PALM SCHINUS TEREBINTHIFOLIUS / BRAZILIAN PEPPERGEIJERA PARVIFLORA / AUSTRALIAN WILLOWSYAGRUS ROMANZOFFIANA / QUEEN PALM SCHINUS TEREBINTHIFOLIUS / BRAZILIAN PEPPERSCHINUS TEREBINTHIFOLIUS / BRAZILIAN PEPPERSYAGRUS ROMANZOFFIANA / QUEEN PALM ABCDEFGHI18"8"8"24"12"8"12"18"8"TO REMAIN, PROTECTED IN PLACETO BE REMOVEDTO BE REMOVEDTO BE REMOVEDTO BE REMOVEDTO BE REMOVEDTO BE REMOVEDTO BE REMOVEDTO BE REMOVEDSYAGRUS ROMANZOFFIANA / QUEEN PALM J8" TO BE REMOVEDOLEA EUROPA / OLIVEK18" TO BE REMOVEDSCHINUS MOLLE / CALIFORNIA PEPPERL24" TO BE REMOVEDSYAGRUS ROMANZOFFIANA / QUEEN PALM M8" TO BE REMOVEDSYAGRUS ROMANZOFFIANA / QUEEN PALM N8" TO BE REMOVEDSYAGRUS ROMANZOFFIANA / QUEEN PALM O8" TO BE REMOVEDSYAGRUS ROMANZOFFIANA / QUEEN PALM P8" TO BE REMOVEDSCHINUS TEREBINTHIFOLIUS / BRAZILIAN PEPPERQ12" TO BE REMOVEDRSFICUS ELASTICA / RUBBER TREER8" TO BE REMOVEDFICUS ELASTICA / RUBBER TREES12" TO BE RELOCATED18S1FICUS ELASTICA / RUBBER TREES112" RELOCATED POSITIONTAG DESCRIPTIONHARDSCAPE LEGENDPRIVATE DRIVEWAY - NEW STAMPED CONCRETE PAVINGSYMBOL DESCRIPTIONNEW ENHANCED PAVING, INTEGRAL COLOR ACID ETCH FINISHNEW SITE CONCRETE WALK, NATURAL GRAY BROOM FINISH1919SCORING PATTERN AS SHOWNSCORING PATTERN AS SHOWN2"24"2SCORING PATTERN AS SHOWN1. FINISHED GRADE.2. 1" WIDE 1/2" THK. WROUGHT IRONCONNECTION,FINISH TO BE ICI-AMERITONE PAINT COLOR#1UM20A 'BASALT'3. 5/8" DIA. TUBULAR WROUGHT IRON PICKETSAT 4" O.C.,FINISH TO BE ICI-AMERITONE, PAINT COLOR#1UM20A 'BASALT'.4. 6"X8"X16" SPLITFACE BLOCK WALL - COLORSHALL BE ORCO 'OTAY RANCH BROWN' (OREQUAL) W/ DAVIS COLOR 'MC66' MORTAR.5. 16"X8"X16" SPLITFACE BLOCKPILASTER-COLOR SHALL BE ORCO 'OTAYRANCH BROWN' (OR EQUAL) W/ DAVIS COLOR'MC66' MORTAR.6. 28"X9"X28" CUSTOM CONCRETE CAP W/ 451/2" BEVEL, COLOR SHALL BE L.M. SCOFIELD'ADOBE TAN' W/ LIGHT SANDBLAST FINISH.7. 9"X3"X16" CUSTOM CONCRETE CAP W/ 45 1/2"BEVEL, COLOR SHALL BE L.M. SCOFIELD'ADOBE TAN' W/ LIGHT SANDBLAST FINISH.N.T.S.bfountain view STREET TREE (24" BOX) 2 Cassia leptophylla / Gold Medallion Tree Melaleuca quinquenervia / Cajeput Tree Tabebuia heterophylla / Pink Tabebuia Umbellularia californica / California Laurel ACCENT TREE (36" BOX) 2 Liquidambar styraciflua / American Sweet Gum Metrosideros excelsus / New Zealand Christmas Tree Michelia doltsopa / Michelia Prosopis chilensis / Chilean MesquitePyrus calleryana `Aristocrat` TM / Aristocrat Flowering Pear Quercus suber / Cork Oak Tabebuia impetiginosa / Pink Trumpet Tree VERTICAL ACCENT TREES (24" BOX) 9 Arbutus unedo / Strawberry Tree Multi-Trunk Callistemon citrinus / Lemon Bottlebrush Lagerstroemia indica / Crape Myrtle SHADE CANOPY TREE (24" BOX) 7 Jacaranda mimosifolia / Jacaranda Laurus nobilis / Sweet Bay Olea europaea `Fruitless` / Fruitless Olive Quercus agrifolia / Coast Live Oak Multi-Trunk Ulmus parvifolia / Chinese Elm SCREENING THEME TREE (24" BOX) 3 Citrus x limon / Lemon Citrus x sinensis `Dwarf Washington` / Dwarf Washington Navel Orange PERIMETER EDGE SHRUB (15 GAL) 67 Dodonaea viscosa `Purpurea` / Purple Leafed Hopseed Bush ACCENT GRASS (1 GAL) 72 Carex spissa / San Diego Sedge Hordeum brachyantherum californicum / California Meadow Barley Juncus patens / California Gray Rush Lomandra longifolia / Mat Rush Nassella cernua / Nodding Needlegrass Nassella pulchra / Purple Needle Grass EVERGREEN ACCENT SHRUB (5 GAL) 106 Agapanthus africanus / Lily of the Nile Agave attenuata / Agave Aloe rudikoppe `Little Gem` / Little Gem Aloe Alpinia zerumbet `Variegata` / Variegated Shell Ginger Anigozanthos x `Big Red` / Big Red Kangaroo Paw Bergenia crassifolia / Siberian-teaBreynia nivosa / Snowbush Calandrinia grandiflora / Rock Purslane Callistemon citrinus `Little John` / Dwarf Bottle Brush Carissa macrocarpa `Tomlinson` / Tomlinson Natal Plum Clivia miniata / Kaffir Lilly Cuphea ignea / Cigar Plant Dianella revoluta `Little Rev` / Little Rev Flax Lily Dianella tasmanica `Variegata` / Flax Lily Dietes bicolor / Fortnight Lily Eriogonum fasciculatum foliolosum / California Buckwheat Heuchera sanguinea / Coral Bells Phormium tenax / New Zealand Flax Russelia equisetiformis / Firecracker Plant Russelia equisetiformis `Lemon Falls` / Yellow Firecracker Plant Salvia clevelandii `Winifred Gillman` / Cleveland Sage Sansevieria trifasciata / Mother-in-law`s Tongue Senecio mandraliscae `Blue Chalk Sticks` / Senecio EVERGREEN VERTICAL SHRUB (5 GAL) 20 Agave attenuata / Agave Bougainvillea x `Torch Glow` / Torch Glow Bush Bougainvillea Ceanothus x `Frosty Blue` / Wild Lilac Dracaena marginata / Red Edged Dracaena Heteromeles arbutifolia / Toyon Leptospermum scoparium `Ruby Glow` / Red New Zealand Tea Tree Yucca gloriosa `Bright Star` / Yellow Spanish EVERGREEN BORDER SHRUB (5 GAL) 462 Bergenia crassifolia / Siberian-tea Bulbine frutescens / Stalked Bulbine Buxus microphylla / Littleleaf Boxwood Buxus microphylla japonica `Winter Gem` / Winter Gem Boxwood Euonymus fortunei / Wintercreeper Ficus retusa `Nitida` / Cuban Laurel Lantana camara `Chapel Hill Yellow` / Lantana Laurus nobilis / Sweet Bay Lavandula dentata / French Lavender Lavandula stoechas / Spanish Lavender Ligustrum texanum / Texas Privet Loropetalum chinense `Sizzling Pink` / Sizzling Pink Fringe Flower Philodendron x `Xanadu` / Philodendron Pittosporum tenuifolium `Silver Sheen` / Tawhiwhi Pittosporum tobira `Miss Muffett` TM / Mock Orange Rhaphiolepis umbellata `Minor` / Yedda Hawthorn Rosa rugosa / Rugosa Rose Salvia clevelandii / Cleveland Sage Salvia clevelandii `Winifred Gillman` / Cleveland Sage Tibouchina urvilleana / Princess Flower Westringia fruticosa / Coast Rosemary VINES (5 GAL) 99 Bougainvillea x `Oo-La-La` TM / Oo-la-la BougainvilleaClytostoma callistegioides / Violet Trumpet Vine Distictis buccinatoria / Blood Red Trumpet Vine Grewia occidentalis / Lavender Starflower Espalier Macfadyena unguis-cati / Yellow Trumpet Vine Wisteria sinensis / Chinese Wisteria EVERGREEN FLOWERING GROUND COVER (FLATS @ 12" O.C.) 9,121 sf Arctostaphylos x `Emerald Carpet` / Emerald Carpet Manzanita Rosmarinus officinalis / Rosemary Thymus praecox arcticus `Reiter`s` / Creeping Thyme Trachelospermum asiaticum `Asiatic` / Asiatic Jasmine Trachelospermum jasminoides / Chinese Star Jasmine CONCEPT PLANT SCHEDULE32021 CHINQUAPIN AVECLUBHOUSECONDO3CONDO2CONDO1RAMPSLOPEDN12' RAMP UP8%DNRAMP8%8%SLOPERAMPRAMPRAMPUP 5%UP 5%UP 5%RAMPUP 5%RAMPFHFHFIREEASEMENTWWWWWWWWWWWWPLOT: 04/30/14 @ 14:40608 CHINQUAPIN AVEOCEAN BREEZECARLSBAD, CAFILE NAME: C:\Users\mahak_000\appdata\local\temp\AcPublish_58380\CP-2.dwg LAYOUT NAME: L1.2 PLOTTED: Friday, May 22, 2015 - 4:14pmSHEETSHEET TITLE:REVISIONSMB / DM2013-549.01AS NOTEDMLASD05/26/20151 12/01/14 CITY COMMENTSAPPLICATION #'S PUD / 14-05 / CDP 14-18 / MS 14-08-OCEANBREEZE2 15/02/19 CITY COMMENTS3 15/05/26 CITY COMMENTSNORTHGRAPHIC SCALE1 INCH = 20 FT.703 16th Street, Suite 100tel (619)296-3150 fax (619) 501-7725www.mlasd.comMcCullough Landscape Architecture, inc.San Diego, California 92101DAVID W.M CULLOUGHOLIC. #4048AEXP. 12-31-16S TTA EGIRERETSEDLANI LFACFIROHCPSDNACERA ECTIT c01-19-2015DATEWATER use / HYDROZONE mapZONE 1 - MODERATE WATER USE - RECYCLED WATER CONCEPTUAL WATER CONSERVATION PLAN201354901L01.2L1.2ZONE 2 - HIGH WATER USE - WATER FEATURE - POTABLE WATERAREA - 8945 SF AREA - 12 SFNOTE:A. IRRIGATION SYSTEMS SHALL BE DESIGNED TO USE RECLAIMED WATER,BUT SHALL BE CONNECTED TO THE POTABLE WATER MAIN UNTIL RECLAIMEDWATER MAIN IS PROVIDED.B. PROVIDE SEPARATE WATER METERS FOR POTABLE WATER ABDRECLAIMED WATER. SYMBOL MANUFACTURER/MODEL/DESCRIPTION Water Meter 1"Existing Water Meter to be salvaged and reused for fountainwater Water Meter 1"New Water Meter assembly for irrigation. To be replaced withrecycled water upon extension of the recycled water main by thecity.Valve NumberValve FlowValve SizeValve Callout###"IRRIGATION SCHEDULE33 PLOT: 04/30/14 @ 14:40608 CHINQUAPIN AVEOCEAN BREEZECARLSBAD, CAFILE NAME: C:\Users\mahak_000\appdata\local\temp\AcPublish_58380\CP-2.dwg LAYOUT NAME: L1.3 PLOTTED: Friday, May 22, 2015 - 4:14pmSHEETSHEET TITLE:REVISIONSMB / DM2013-549.01AS NOTEDMLASD05/26/20151 12/01/14 CITY COMMENTSAPPLICATION #'S PUD / 14-05 / CDP 14-18 / MS 14-08-OCEANBREEZE2 15/02/19 CITY COMMENTS3 15/05/26 CITY COMMENTS703 16th Street, Suite 100tel (619)296-3150 fax (619) 501-7725www.mlasd.comMcCullough Landscape Architecture, inc.San Diego, California 92101DAVID W.M CULLOUGHOLIC. #4048AEXP. 12-31-16S TTA EGIRERETSEDLANI LFACFIROHCPSDNACERA ECTIT c01-19-2015DATE1 INCH = 16 FT.OVERALL SITE AESTHETICS201354901L01.3L1.3NOTE: ALL COLORS ARE APPROXIMATE DUE TO COMPUTER GRAPHICS AND PLOTTER EFFICIENCY. PLEASE SEE MATERIAL BOARDS FOR ACTUAL COLOR SAMPLES.