Loading...
HomeMy WebLinkAbout2016-01-06; Planning Commission; ; PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 - GARFIELD CUSTOM BEACH HOMES The City of Carlsbad Planning Division A REPORT TO THE PLANNING COMMISSION Item No. Application complete date: September 1, 2015 P.C. AGENDA OF: January 6, 2016 Project Planner: Austin Silva Project Engineer: David Rick SUBJECT: PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES – Request for approval of a Planned Development Permit, Site Development Plan, Coastal Development Permit, and Minor Subdivision to allow for the demolition of a single- family home and the construction of a two-unit, detached single-family residential air- space condominium development on a .15 acre lot located at 3806 Garfield Avenue in Local Facilities Management Zone 1 and in the Mello II segment of the Local Coastal Program. This project is not located within the appealable area of the California Coastal Commission. The City Planner has determined that this project is exempt from the requirements of the California Environmental Quality Act (CEQA) pursuant to Section 15332 “In-Fill Development Projects” of the State CEQA Guidelines and will not have any adverse significant impact on the environment. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7144 APPROVING Planned Development Permit (PUD 15-17), Site Development Plan (SDP 15-16), Coastal Development Permit (CDP 15-34), and Minor Subdivision (MS 15-11), based upon the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND The applicant is proposing to demolish a single-family home and to construct two detached, single- family residential air-space condominiums on a .15 acre infill site within the Beach Area Overlay Zone (BAOZ). The proposed condominium project requires the approval of a Planned Development Permit, Site Development Plan, Coastal Development Permit, and Minor Subdivision. The subdivision is considered minor because it involves the division of land into four or less condominiums. Proposed Construction: The two proposed residential structures take on a contemporary beach style architecture with simple, rectangular massing with a combination of gentle sloped and flat roofs. Each of the units are unique with their own individual design, color scheme, and floor plan. The homes use stucco as the primary building material and include design details such as wood beams, wood trellises, wood columns, wood “knee braces,” “eyebrow” roofs, and stainless steel cable railings. Most of the roofs incorporate a 3:12 roof pitch and use composition shingles. Both homes use a light neutral color for the primary stucco use, with house one using earth tones for accents and trims and house two utilizing charcoal tones for the accents and trims. The two homes have three levels, each with their own floor plan with house number one having 2,771 square feet of living area and house number two containing 3,154 square feet of living area. Both homes have two-car garages which are accessed from Hemlock Avenue. Each home has balconies on 2 PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES January 6, 2016 Page 2 the second and third floors. The underlying lot will be held in common interest divided between the two airspace condominiums. The common area includes, but is not limited to the driveways, guest parking and landscaping. The site will be graded and lowered a maximum of approximately two feet with small retaining walls around portions of the property line and a small retaining wall between home one and home two. Grading quantities include 200 cubic yards of cut, 20 cubic yards of fill, and 180 cubic yards of export. Table A below includes the General Plan designations, zoning and current land uses of the project site and surrounding properties. TABLE A Location General Plan Designation Zoning Current Land Use Site R-23 - Residential R-3 Single-family residential North R-23 - Residential R-3 Duplex South R-23 - Residential R-3 Multi-family residential East R-23 - Residential R-3 Single-family residential West R-23 - Residential R-2 Duplex Table B below includes the project site’s gross and net acreage, the number of dwelling units allowed by the General Plan’s Growth Management Control Point (GMCP) density and the proposed projects number of dwelling units and density. TABLE B Gross Acres Net Acres DUs Allowed at GMCP Density DUs Proposed and Project Density 0.15 acres 0.15 acres 2.9 units 2 units at 13.8 du/ac III. ANALYSIS The project is subject to the following regulations: A. R-23 – Residential General Plan Land Use designation; B. Multiple Family Residential Zone (R-3) Planned Development Regulations and Beach Area Overlay Zone (BAOZ) (C.M.C. Chapters 21.16, 21.45 and 21.82); C. Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC Chapter 21.201) and Chapter 21.203 (Coastal Resource Protection Overlay Zone); D. City Council Policies No. 44 and 66 (Neighborhood Architectural Design Guidelines and Livable Neighborhoods); E. Subdivision Ordinance (C.M.C. Title 20); F. Inclusionary Housing Ordinance (C.M.C. Chapter 21.85); and G. Growth Management Ordinance (C.M.C. Chapter 21.90) and Zone 1 Local Facilities Management Plan. The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable regulations and policies. The project’s compliance with each of the above regulations is discussed in detail in the sections below. PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES January 6, 2016 Page 3 A. General Plan R-23 - Residential Land Use Designation The General Plan Land Use designation for the property is Residential High (R-23). The R-23 Land Use designation allows residential development at a density range of 15-23 dwelling units per acre with a Growth Management Control Point (GMCP) of 19 dwelling units per acre. The project site has a net developable acreage of 0.15 acres. Table C below indicates the number of units yielded by the R-23 density requirement for the site: TABLE C R - 23 DENSITY REQUIREMENTS FOR PROJECT SITE R - 23 Density Unit Yield Minimum 15 du/ac 2.3 (15 x .15 acres) GMCP 19 du/ac 2.9 (19 x .15 acres) Maximum 23 du/ac 3.5 (23 x .15 acres) The project proposes to construct two dwelling units on the project site which is 0.3 units below the minimum density yield and 0.9 units below the Growth Management Control Point. The resulting density is 13.8 du/ac. Pursuant to Carlsbad Municipal Code Section 21.53.230, unit yields with a fractional unit below 0.5 for the minimum density yield may be rounded-down. In addition, any unit yields rounded-down pursuant to this provision that result in a density below the minimum density of the applicable land use designation shall be considered consistent with the General Plan. Therefore, this project will deposit .9 dwelling units into the Dwelling Unit Bank; these excess dwelling units are available for allocation to other projects. Accordingly, there is no net loss of residential unit capacity and there are adequate properties identified in the Housing Element allowing residential development with a unit capacity adequate to satisfy the city’s share of the regional housing need. Lastly, the project complies with the Elements of the General Plan as outlined in Table “D” below: TABLE D – GENERAL PLAN COMPLIANCE ELEMENT USE, CLASSIFICATION, GOAL, OBJECTIVE OR PROGRAM PROPOSED USES & IMPROVEMENTS COMPLIANCE Land Use Site is designated for Residential High density, (R- 23; 15-23 du/ac) with a GMCP of 19 du/ac. Two detached residential condominiums are proposed in association with the project. As discussed above, although the residential project density at 13.8 dwelling units per acre (2 DUs) is below the minimum R-23 density of 15 du/ac, the project can be found consistent with the General Plan pursuant to CMC Section 21.53.230. In addition, 0.9 dwelling units will be deposited in the City’s excess dwelling unit bank consistent with Housing Element Program 3.2 and City Council Policy 43. Yes PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES January 6, 2016 Page 4 TABLE D – GENERAL PLAN COMPLIANCE (CONTINUED) ELEMENT USE, CLASSIFICATION, GOAL, OBJECTIVE OR PROGRAM PROPOSED USES & IMPROVEMENTS COMPLIANCE Housing Provisions for affordable housing. The project is conditioned to pay an affordable housing in-lieu fee for one unit. If building permits project have not been applied for within two years of demolishing the existing single- family home on-site, then the fee will have to be paid for two units. Yes Public Safety Reduce fire hazards to an acceptable level. The project site is located within a five minute response time of Fire Station No. 1 and has been designed to comply with the fire code, including provisions for an automatic sprinkler system within each dwelling unit. Yes Open Space & Conservation Minimize the environmental impacts to sensitive resources within the City. Utilize Best Management Practices for control of storm water and to protect water quality. The project will not create any environmental impacts to the previously graded and developed site. The project is conditioned to conform to all NPDES requirements and has been designed to include Low Impact Design (LID) elements. Yes Noise Require that a "Noise" Study be submitted with all discretionary applications for residential projects of five or more single-family dwelling units or any multiple-family dwelling units located within or 500-feet beyond the 60 dB(a) CNEL noise contour lines as shown on Map 2: Future Noise Exposure Contour Map. The project consists of two detached single-family dwelling units and therefore a noise study is not required. However, the project has been conditioned to meet a 45 dB(a) CNEL interior noise level when openings to the exterior of the residence are open or closed. If openings are required to be closed to meet the interior noise standard, then mechanical ventilation shall be provided. Yes Circulation Construct roadway improvements needed to serve proposed development. All public facilities including curb, gutter and sidewalk are conditioned to be built along the property frontage (Garfield Street and Hemlock Avenue). Yes B. Multiple Family Residential Zone (R-3) and Planned Development Regulations The proposed project is required to comply with all applicable use and development standards of the Carlsbad Municipal Code (CMC) including the Multiple Family (R-3) Zone (C.M.C. Chapter 21.16) and Planned Developments (C.M.C. Chapter 21.45). The two-unit detached single-family residential air-space condominium project meets or exceeds the requirements of the R-3 Zone and BAOZ as outlined in Table “E” below. The Planned Development regulations provide most of the development standards with the exception of those listed in the table PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES January 6, 2016 Page 5 below. The project complies with all applicable development standards for Planned Developments (C.M.C Chapter 21.45). Please refer to Attachment No. 4 for an analysis of project compliance with Tables C & E of the Planned Development regulations. TABLE E – R-3 AND BAOZ COMPLIANCE R-3 Standards Required Proposed Comply Setbacks Interior Side: 5’ Rear: 10’ Interior Side (South): 5' Street Side (North): 10' Rear: 10’ Yes Lot Coverage 60% max 51% Yes BAOZ Standards Required Proposed Comply Building Height 30’ with minimum 3:12 roof pitch or 24’ if less than a 3:12 roof pitch 29’ 9 ¾” Yes C. Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC Chapter 21.201) and Chapter 21.203 (Coastal Resource Protection Overlay Zone) The project site is located within the Mello II Segment of the Local Coastal Program and is not in the appeal jurisdiction. The project’s compliance with each of these programs and ordinances is discussed below: 1. Mello II Segment of the Certified Local Coastal Program and all applicable policies. The project is located in the Mello II Local Coastal Program Segment. The subject site has an LCP Land Use Plan designation of Residential High (R-23), which allows for a density of 15-23 du/acre and 19 du/acre at the Growth Management Control Point (GMCP). However, the project density of 13.8 du/ac is consistent with the R-23 General Plan Land Use designation as discussed in Section A above. Therefore the project is consistent with the Mello II Segment of the LCP. The project consists of the demolition of a single-family house and the construction of two single-family residential airspace condominiums in an area designated for residential development. The proposed condominiums are compatible with the surrounding development of one and two-story single-family and multi-family structures. The three-story homes will not obstruct views of the coastline as seen from public lands or the public right-of-way, nor otherwise damage the visual beauty of the coastal zone. No agricultural uses currently exist on the previously graded site, nor are there any sensitive resources located on the developable portion of the site. The proposed condominiums are not located in an area of known geologic instability or flood hazard. Since the site does not have frontage along the coastline, no public opportunities for coastal shoreline access are available from the subject site. Furthermore, the residentially designated site is not suited for water-oriented recreation activities. The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (Chapter 21.203 of the Zoning Ordinance) in that the project will adhere to the City's Master Drainage Plan, Grading Ordinance, Storm Water Ordinance, Standard Urban Storm Water Mitigation Plan (SUSMP) and Jurisdictional Urban Runoff Management Program (JURMP) to avoid increased urban runoff, pollutants, and soil erosion. No steep slopes or native vegetation is located on the subject property and the site is not located in an area prone to landslides, or susceptible to accelerated erosion, floods, or liquefaction. PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES January 6, 2016 Page 6 D. City Council Policies No. 44 (Neighborhood Architectural Design Guidelines) and 66 (Livable Neighborhoods) The project is subject to City Council Policy No. 44 – Neighborhood Architectural Design Guidelines and City Council Policy No. 66 – Livable Neighborhoods. The proposed two-unit, detached single-family residential air-space condominium project proposes a deviation to architectural guideline #9 and #16 of City Council Policy No. 44. Architectural guidelines seven, eight, and nine are regarding single-story requirements. Guideline number seven requires 15% of the homes to be single-story, whereas number eight allows 20% of the homes to be exempt from the single-story requirement. Architectural guideline number nine states: The remaining total number of homes shall comply with one of the following guidelines  The home shall have a single-story building edge with a depth of not less than 8 feet and shall run the length of the building along one side except for tower elements. The roof covering the single-story element shall incorporate a separate roof plane and shall be substantially lower than the roof for the two-story element. Porches and porte-cochere elements shall qualify as a single-story edge. Houses with courtyards that are a minimum of 15 feet wide located along the side of the house and setback a minimum of 15 feet from the property line are not required to have a single-story building edge.  The home shall have a single-story building edge with a depth of not less than 5 feet and shall run the length of the building along one side. The roof of the single-story element shall be substantially lower than the roof for the two-story element of the building.  The home shall have a single-story building edge with a depth of not less than 3 feet for 40% of the perimeter of the building. Both homes propose to deviate from this requirement. The policy is geared toward traditional two-story single-family tract development, but applies to detached single-family condominiums as well. The property’s R-3 zoning allows for detached single- family condominiums to go above the maximum two-story requirement of the R-1 (One-Family Residential) zone and therefore the guideline regarding single-story building edge. The maximum height allowed in the R-1 zone is 30 feet with a minimum 3:12 roof pitch, whereas the maximum height allowed in the R-3 zone is 35 feet with a minimum 3:12 roof pitch. City Council Policy No. 44 allows an applicant to propose buildings that comply with the purpose and intent of the policy which states: “The purpose and intent of the architectural guidelines are to ensure that a variety of architectural elements are incorporated into single-family homes and two-family structures so that they: a) are visually interesting, b) have sufficient building articulation to reduce their bulk and mass, c) are in scale to their lot size, and d) strongly contribute to the creation of livable neighborhoods.” A justification of how the proposed project complies with the intent and purpose of City Council Policy No. 44 (Guideline #9 and #16) are provided in Table “F” below. PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES January 6, 2016 Page 7 TABLE F – CITY COUNCIL POLICY NO. 44 INTENT AND PURPOSE COMPLIANCE FOR GUIDELINE #9 Goal Justification Visually interesting. The proposed homes provide covered first level porches, second story decks and third story balconies. All houses have a variety of materials consisting of colored stucco, wood beams, wood columns, wood trellises, wood knee braced, “eyebrow” roofs, and steel cable railing around the balconies. Sufficient building articulation to reduce bulk and mass. The second and third story balconies provide articulation. The third story living area is significantly reduced in size compared to the second story. Both of these features reduce the bulk and mass of the project. In scale to their lot size. The project is permitted to have a lot coverage up to 60%. This project proposes a lot coverage of (51%). The project is in scale with the size of the lot. Strongly contribute to the creation of livable neighborhoods. The project site could accommodate up to three attached multi-family dwellings given the existing zoning (R-3) and General Plan Land Use (R-23). The project site is bordered to the north and west by a single-family home. There is a multi-family project to the east of the project site. By developing two detached single-family condominiums, the project blends into the existing area and provides future occupants with more privacy than an attached multi-family development. Please refer to Attachments No. 5 and 6 (Exhibits “B” and “C”) for a detailed analysis of project compliance with the rest of City Council Policy No. 44 and full compliance with City Council Policy No. 66. E. Subdivision Ordinance The Land Development Engineering Division has reviewed the proposed Tentative Parcel Map and has found that the subdivision complies with all applicable requirements of the Subdivision Map Act and the City’s Subdivision Ordinance (Title 20) for Minor Subdivisions. The subdivision is considered minor because it involves the division of land into four or fewer condominiums. The project has been conditioned to install all infrastructure-related improvements and the necessary easements for these improvements concurrent with the development. F. Inclusionary Housing Ordinance For all residential development less than seven units, the inclusionary housing requirement may be satisfied through the payment of an inclusionary housing in-lieu fee. However, pursuant to Carlsbad Municipal Code Section 21.85.030D.3, the construction of a new residential structure which replaces a residential structure that was destroyed or demolished within two years prior to the application for a building permit for the new residential structure is exempt from affordable housing requirements, provided that the number of residential units is not increased from the number of residential units of the previously destroyed or demolished residential structure. The proposal to demolish the existing single-family home and construct a two-unit residential condominium project has been conditioned to pay the applicable housing in-lieu fee for one unit if building permits for the two-unit project have been applied for within two years of demolishing the existing unit on-site. If building permits are not applied for within two years of demolishing the existing unit, the developer will be required to pay the fee for two units. PUD 15-17/SDP 15-16/CDP 15-34/MS 15-11 – GARFIELD CUSTOM BEACH HOMES January 6, 2016 Page 8 G. Growth Management The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of the City. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in Table “G” below. TABLE G – GROWTH MANAGEMENT COMPLIANCE STANDARD IMPACTS COMPLIANCE City Administration 3.975 sq. ft. Yes Library 3.71 sq. ft. Yes Waste Water Treatment 1 EDU Yes Parks 0.014 acre Yes Drainage <1 CFS Yes Circulation 10 ADT (net increase of 10 ADT) Yes Fire Station No. 1 Yes Open Space 0 acres N/A Schools Carlsbad (E=.71/M=.21/HS = .19) Yes Sewer Collection System 1 EDU Yes Water 220 GPD Yes The project proposes two dwelling units whereas the unit yield at the GMCP of the property is 2.9 dwelling units. The proposed two-unit project is 0.9 units below the Growth Management Control Point density for this R-23 designated property. Consistent with the General Plan and Policy No. 43, 0.9 dwelling units will be deposited in the City’s excess dwelling unit bank. IV. ENVIRONMENTAL REVIEW The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption of the State CEQA Guidelines. The project is consistent with the General Plan as well as with the Zoning Ordinance, the project site is within the City limits, is less than 5 acres in size, and is surrounded by urban uses; there is no evidence that the site has value as habitat for endangered, rare, or threatened species; approval of the project will not result in significant effects relating to traffic, noise, air quality, or water quality; and the site can be adequately served by all required utilities and public services. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project. A Notice of Exemption will be filed by the City Planner upon final project approval. ATTACHMENTS: 1. Planning Commission Resolution No. 7144 2. Location Map 3. Disclosure Statement 4. Planned Development Tables C & E 5. City Council Policy No. 44 Compliance Table 6. City Council Policy No. 66 Compliance Table 7. Reduced Exhibits 8. Full Size Exhibits “A” – “U” dated January 6, 2016 HEMLOCK AVG A R F I E L D S T REDWOOD AVJUNIPER AVPUD 15-17 / SDP 15-16 / CDP 15-34 / MS 15-11Garfield Custom Beach Homes SITE MAP J SITE EL CAMINO R E A LLA COSTA AV A L G A R D C A R L S B A D B L ATTACHMENT 4 PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT C.1 Density Per the underlying General Plan designation. When two or more general plan land use designations exist within a planned development, the density may be transferred from one general plan designation to another with a general plan amendment. N/A C.2 Arterial Setbacks All dwelling units adjacent to any arterial road shown on the Circulation Element of the General Plan shall maintain the following minimum setbacks from the right-of-way: Prime Arterial 50 Feet Major Arterial 40 Feet Secondary Arterial 30 Feet Carlsbad Boulevard 20 Feet N/A Half (50%) of the required arterial setback area located closest to the arterial shall be fully landscaped to enhance the street scene and buffer homes from traffic on adjacent arterials, and:  Shall contain a minimum of one 24” box tree for every 30 lineal feet of street frontage; and  Shall be commonly owned and maintained N/A Project perimeter walls greater than 42 inches in height shall not be located in the required landscaped portion of the arterial setback, except noise attenuation walls that:  Are required by a noise study, and  Due to topography, are necessary to be placed within the required landscaped portion of the arterial setback. N/A C.3 Permitted Intrusions into Setbacks/ Building Separation Permitted intrusions into required building setbacks shall be the same as specified in Section 21.46.120 of this code. The same intrusions specified in Section 21.46.120 shall be permitted into required building separation. Project Complies. All intrusions (i.e., roof eaves and balconies) into the required setbacks and building separation meet Section 21.46.120. C.4 Streets Private Minimum right-of-way width 56 feet NA. Project is not proposing a private street. Minimum curb-to-curb width 34 feet Minimum parkway width (curb adjacent) 5.5 feet, including curb Minimum sidewalk width 5 feet (setback 6 inches from property line) Public Minimum right-of-way width 60 feet NA. Project is not proposing a public street. Minimum curb-to-curb width 34 feet Minimum parkway width (curb adjacent) 7.5 feet, including curb Minimum sidewalk width 5 feet (setback 6 inches from property line) Street Trees within parkways One-family dwellings and twin homes on small-lots A minimum of one street tree (24-inch box) per lot is required to be planted in the parkway along all streets. N/A Condominium projects Street trees shall be spaced no further apart than 30 feet on center within the parkway. Street trees provided every 30 feet Tree species should be selected to create a unified image for the street, provide an effective canopy, avoid sidewalk damage and minimize water consumption. Proposed queen palms are consistent with the existing queen palm on the Hemlock Ave. frontage. PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT C.5 Drive-aisles 3 or fewer dwelling units Minimum 12 feet wide when the drive-aisle is not required for emergency vehicle access, as determined by the Fire Chief. N/A If the drive-aisle is required for emergency vehicle access, it shall be a minimum of 20 feet wide. 4 or more dwelling units Minimum 20 feet wide. N/A All projects No parking shall be permitted within the minimum required width of a drive-aisle. N/A A minimum 24-foot vehicle back-up/maneuvering area shall be provided in front of garages, carports or uncovered parking spaces (this may include driveway area, drive-aisles, and streets). N/A Additional width may be required for vehicle/emergency vehicle maneuvering area. N/A Parkways and/or sidewalks may be required. All public facilities including curb, gutter and sidewalk have been conditioned to be constructed along the property frontage. No more than 24 dwelling units shall be located along a single-entry drive-aisle. N/A All drive-aisles shall be enhanced with decorative pavement. N/A C.6 Number of Visitor Parking Spaces Required (1) Projects with 10 units or fewer A .30 space per each unit. Project complies. There are guest parking spaces located in front of both garages. Projects 11 units or more A .25 space per each unit. When calculating the required number of visitor parking spaces, if the calculation results in a fractional parking space, the required number of visitor parking spaces shall always be rounded up to the nearest whole number. PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARD REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT C.7 Location of Visitor Parking On Private/ Public Streets On-street visitor parking is permitted on private/public streets, subject to the following:  The private/public street is a minimum 34-feet wide (curb-to-curb)  There are no restrictions that would prohibit on-street parking where the visitor parking is proposed  The visitor parking spaces may be located: o Along one or both sides of any private/public street(s) located within the project boundary, and o Along the abutting side and portion of any existing public/private street(s) that is contiguous to the project boundary N/A In parking bays along public/private streets within the project boundary, provided the parking bays are outside the minimum required street right-of-way width. N/A When visitor parking is provided as on-street parallel parking, not less than 24 lineal feet per space, exclusive of driveway/drive-aisle entrances and aprons, shall be provided for each parking space, except where parallel parking spaces are located immediately adjacent to driveway/drive-aisle aprons, then 20 lineal feet may be provided. N/A Within the Beach Area Overlay Zone, on-street parking shall not count toward meeting the visitor parking requirement. N/A On Drive-aisles Visitor parking must be provided in parking bays that are located outside the required minimum drive-aisle width. N/A On a Driveway Outside the Beach Area Overlay Zone One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or more. N/A For projects with 10 or fewer units, all required visitor parking may be located within driveways (located in front of a unit’s garage), provided that all dwelling units in the project have driveways with a depth of 20 feet or more. N/A Within the Beach Area Overlay Zone One required visitor parking space may be credited for each driveway in a project that has a depth of 40 feet or more. N/A If the streets within and/or adjacent to the project allow for on-street parking on both sides of the street, then visitor parking may be located in a driveway, subject to the following:  All required visitor parking may be located within driveways (located in front of a unit’s garage), provided that all dwelling units in the project have driveways with a depth of 20 feet or more.  If less than 100% of the driveways in a project have a depth of 20 feet or more, then a .25 visitor parking space will be credited for each driveway in a project that has a depth of 20 feet or more (calculations resulting in a fractional parking space credit shall always be rounded down to the nearest whole number). Project complies. Both units can accommodate parking for guests in a driveway with a depth of at least 20 feet. All projects The minimum driveway depth required for visitor parking (20 feet or 40 feet) applies to driveways for front or side- loaded garages, and is measured from the property line, back of sidewalk, or from the edge of the drive-aisle, whichever is closest to the structure. Project complies. Both units can accommodate parking for guests in a driveway with a depth of at least 20 feet. Compact Parking For projects of more than 25 units, up to 25% of visitor parking may be provided as compact spaces (8 feet by 15 feet). No overhang is permitted into any required setback area or over sidewalks less than 6 feet wide. N/A PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARD REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT For all projects within the Beach Area Overlay Zone, up to 55% of the visitor parking may be provided as compact spaces (8 feet by 15 feet). N/A Distance from unit Visitor parking spaces must be located no more than 300 feet as measured in a logical walking path from the entrance of the unit it could be considered to serve. N/A C.8 Screening of Parking Areas Open parking areas should be screened from adjacent residences and public rights- of-way by either a view-obscuring wall, landscaped berm, or landscaping, except parking located within a driveway. N/A C.9 Community Recreational Space (1) Community recreational space shall be provided for all projects of 11 or more dwelling units, as follows: N/A Minimum community recreational space required Project is NOT within R-23 general plan designation 200 square feet per unit Project IS within R-23 general plan designation 150 square feet per unit Projects with 11 to 25 dwelling units Community recreational space shall be provided as either (or both) passive or active recreation facilities. N/A Projects with 26 or more dwelling units Community recreational space shall be provided as both passive and active recreational facilities with a minimum of 75% of the area allocated for active facilities. N/A Projects with 50 or more dwelling units Community recreational space shall be provided as both passive and active recreational facilities for a variety of age groups (a minimum of 75% of the area allocated for active facilities). N/A For projects consisting of one-family dwellings or twin homes on small-lots, at least 25% of the community recreation space must be provided as pocket parks.  Pocket park lots must have a minimum width of 50 feet and be located at strategic locations such as street intersections (especially “T-intersections”) and where open space vistas may be achieved. N/A All projects (with 11 or more dwelling units) Community recreational space shall be located and designed so as to be functional, usable, and easily accessible from the units it is intended to serve. N/A Credit for indoor recreation facilities shall not exceed 25% of the required community recreation area. N/A Required community recreation areas shall not be located in any required front yard and may not include any streets, drive-aisles, driveways, parking areas, storage areas, slopes of 5% or greater, or walkways (except those walkways that are clearly integral to the design of the recreation area). N/A Recreation Area Parking In addition to required resident and visitor parking, recreation area parking shall be provided, as follows: 1 space for each 15 residential units, or fraction thereof, for units located more than 1,000 feet from a community recreation area. N/A The location of recreation area parking shall be subject to the same location requirements as for visitor parking, except that required recreation area parking shall not be located within a driveway(s). N/A Examples of recreation facilities include, but are not limited to, the following: PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARD REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT Active Swimming pool area Children’s playground equipment Spa Courts (tennis, racquetball, volleyball, basketball) Recreation rooms or buildings Horseshoe pits Pitch and putt Grassy play areas with a slope of less than 5% (minimum area of 5,000 square feet and a minimum dimension of 50 feet) Any other facility deemed by the City Planner to satisfy the intent of providing active recreational facilities. Passive Benches Barbecues Community gardens Grassy play areas with a slope of less than 5%. C.10 Lighting Lighting adequate for pedestrian and vehicular safety shall be provided. N/A C.11 Reserved C.12 Recreational Vehicle (RV) Storage (1) Required for projects with 100 or more units, or a master or specific plan with 100 or more planned development units. Exception: RV storage is not required for projects located within the R-15 or R-23 land use designations. N/A 20 square feet per unit, not to include area required for driveways and approaches. Developments located within master plans or residential specific plans may have this requirement met by the common RV storage area provided by the master plan or residential specific plan. RV storage areas shall be designed to accommodate recreational vehicles of various sizes (i.e. motorhomes, campers, boats, personal watercraft, etc.). N/A The storage of recreational vehicles shall be prohibited in the front yard setback and on any public or private streets or any other area visible to the public. A provision containing this restriction shall be included in the covenants, conditions and restrictions for the project. All RV storage areas shall be screened from adjacent residences and public rights-of-way by a view-obscuring wall and landscaping. N/A C.13 Storage Space 480 cubic feet of separate storage space per unit. Project complies. Both units will provide a two-car garage (20 ft. x 20 ft. minimum interior space), which satisfies the storage space requirement. If all storage for each unit is located in one area, the space may be reduced to 392 cubic feet. Required storage space shall be separately enclosed for each unit and be conveniently accessible to the outdoors. NA. Required storage space may be designed as an enlargement of a covered parking structure provided it does not extend into the area of the required parking stall, and does not impede the ability to utilize the parking stall (for vehicle parking). NA. A garage (12’x20’ one-car, 20’x20’ two-car, or larger) satisfies the required storage space per unit. NA. This requirement is in addition to closets and other indoor storage areas. NA. PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT E.1 Livable Neighborhood Policy Must comply with city council Policy 66, Principles for the Development of Livable Neighborhoods. See Separate Compliance Chart - Attachment 6 E.2 Architectural Requirements One-family and two- family dwellings Must comply with city council Policy 44, Neighborhood Architectural Design Guidelines See Separate Compliance Chart - Attachment 5 Multiple- family dwellings There shall be at least three separate building planes on all building elevations. The minimum offset in planes shall be 18 inches and shall include, but not be limited to, building walls, windows, and roofs. N/A All building elevations shall incorporate a minimum of four complimentary design elements, including but not limited to:  A variety of roof planes;  Windows and doors recessed a minimum of 2 inches;  Decorative window or door frames;  Exposed roof rafter tails;  Dormers;  Columns;  Arched elements;  Varied window shapes;  Exterior wood elements;  Accent materials such as brick, stone, shingles, wood, or siding;  Knee braces; and  Towers. N/A E.3 Maximum Coverage 60% of total project net developable acreage. Proposed building coverage is 51% of the net lot area (0.15 acres). Project complies. E.4 Maximum Building Height Same as required by the underlying zone, and not to exceed three stories (1)(7) The project is located within the BAOZ, and therefore pursuant to Footnote #1 below, building height shall be subject to the requirements of C.M.C. Chapter 21.82. Pursuant to C.M.C. Section 21.82.050, no residential structure shall exceed 30 ft. when providing a minimum 3:12 roof pitch, or 24 ft. when providing less than a 3:12 roof pitch. The project is proposing a building height of 29’9 ¾ " with a 3:12 roof pitch. 2nd and 3rd floor roof decks are less than 24 ft. in height. Project complies. Projects within the RH general plan designation (1)(7) 40 feet, if roof pitch is 3:12 or greater NA. Project is located within the BAOZ. Therefore, pursuant to Footnote #1 below, building height shall be subject to the requirements of C.M.C. Chapter 21.82. As discussed above, project complies. 35 feet, if roof pitch is less than 3:12 Building height shall not exceed three stories PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT E.5 Minimum Building Setbacks From a private or public street(2)(3) Residential structure 10 feet The residential structure is setback a minimum of 10 feet from Hemlock Avenue and Garfield Street as measured from the outside edge of the required street right-of-way width. The direct entry garages are setback a minimum of 20 feet. Project complies. Direct entry garage 20 feet From a drive- aisle(4) Residential structure (except as specified below) 5 feet, fully landscaped (walkways providing access to dwelling entryways may be located within required landscaped area) N/A Residential structure – directly above a garage 0 feet when projecting over the front of a garage. N/A Garage 3 feet N/A Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener. Projects of 25 units or less within the R-15 and R-23 general plan designations 0 feet (residential structure and garage) N/A Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener. N/A Balconies/decks (unenclosed and uncovered) 0 feet N/A May cantilever over a drive-aisle, provided the balcony/deck complies with all other applicable requirements, such as:  Setbacks from property lines  Building separation  Fire and Engineering Department requirements From the perimeter property lines of the project site (not adjacent to a public/private street) The building setback from an interior side or rear perimeter property line shall be the same as required by the underlying zone for an interior side or rear yard setback. The underlying zone for the project is R-3. The required interior side yard setback for R-3 is 10 % of the lot width, which is 5 feet. The project has an interior side yard setback of 5 feet. The required rear yard setback for R-3 is twice the required side yard setback, which is 10 feet. The project provides a rear yard setback of 10 feet. Project complies. E.6 Minimum Building Separation 10 feet 11’ 11 7/8” PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT E.7 Resident Parking (6) All dwelling types If a project is located within the RH general plan designation, resident parking shall be provided as specified below, and may also be provided as follows:  25% of the units in the project may include a tandem two-car garage (minimum 12 feet x 40 feet).  Calculations for this provision resulting in a fractional unit may be rounded up to the next whole number. N/A One-family and two- family dwellings 2 spaces per unit, provided as either:  a two-car garage (minimum 20 feet x 20 feet), or  2 separate one-car garages (minimum 12 feet x 20 feet each)  In the R-W Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered space (5) A two-car garage is provided for each dwelling with minimum 20 feet x 20 feet interior dimensions. Project complies. Multiple- family dwellings Studio and one- bedroom units 1.5 spaces per unit, 1 of which must be covered (5) N/A When calculating the required number of parking spaces, if the calculation results in a fractional parking space, the required number of parking spaces shall always be rounded up to the nearest whole number. Units with two or more bedrooms 2 spaces per unit, provided as either:  a one-car garage (12 feet x 20 feet) and 1 covered or uncovered space; or (5)  a two-car garage (minimum 20 feet x 20 feet), or  2 separate one-car garages (minimum 12 feet x 20 feet each)  In the R-W Zone and the Beach Area Overlay Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered space (5) N/A. Required parking may be provided within an enclosed parking garage with multiple, open parking spaces, subject to the following:  Each parking space shall maintain a standard stall size of 8.5 feet by 20 feet, exclusive of supporting columns; and  A backup distance of 24 feet shall be maintained in addition to a minimum 5 feet turning bump-out located at the end of any stall series. N/A Required resident parking spaces shall be located no more than 150 feet as measured in a logical walking path from the entrance of the units it could be considered to serve. N/A PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT E.8 Private Recreational Space One-family, two-family, and multiple- family dwellings Required private recreational space shall be designed so as to be functional, usable, and easily accessible from the dwelling it is intended to serve. Each deck and/or balcony are functional, usable and easily accessible from within each unit. Required private recreational space shall be located adjacent to the unit the area is intended to serve. Each home provides a private recreation area in the form of ground level area, second level balconies and third level decks which meet or exceed the 200 total sq. ft. requirement. The required private recreational space (decks and balconies) is provided for each unit. Required private recreational space shall not be located within any required front yard setback area, and may not include any driveways, parking areas, storage areas, or common walkways. The required private recreational space is not located within any front yard setback area, driveway, parking areas, storage areas, or common walkways. One-family and two- family dwellings Minimum total area per unit Projects not within the R-15 or R-23 general plan designations 400 square feet The project is located within the RH general plan designation and provides at least 200 sq. ft. of recreational space per dwelling as discussed above. Project complies. Projects within the R-15 or R-23 general plan designations 200 square feet May consist of more than one recreational space. Recreational space is located at the ground level, second level and third level of each dwelling. Project complies. May be provided at ground level and/or as a deck/balcony on a second/third floor or roof. Balconies and decks are included in the recreational space. Project complies. If provided at ground level Minimum dimension Not within the R-15 or R-23 general plan designations 15 feet The project is located within the RH general plan designation and provides at least a 10 ft. dimension for required recreational space located at the ground level. Project complies. Within the R-15 or R-23 general plan designations 10 feet Shall not have a slope gradient greater than 5%. The ground level does not have a slope of greater than 5%. Project complies. Attached solid patio covers and decks/balconies may project into a required private recreational space, subject to the following:  The depth of the projection shall not exceed 6 feet (measured from the wall of the dwelling that is contiguous to the patio/deck/balcony). The length of the projection shall not be limited, except as required by any setback or lot coverage standards. N/A Open or lattice-top patio covers may be located within the required private recreation space (provided the patio cover complies with all applicable standards, including the required setbacks). N/A If provided above ground level as a deck/ balcony or roof deck Minimum dimension 6 feet The project provides at least a 6 ft. dimension and a minimum 60 sf in area for required recreational space located above ground level as a balcony or deck. Project complies. Minimum area 60 square feet Multiple-family dwellings Minimum total area per unit (patio, porch, or balcony) 60 square feet N/A Minimum dimension of patio, porch or balcony 6 feet N/A PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF NO SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT Projects of 11 or more units that are within the R-23 general plan designation may opt to provide an additional 75 square feet of community recreation space per unit (subject to the standards specified in Table C of this Chapter), in lieu of providing the per unit private recreational space specified above. N/A (1) If a project is located within the Beach Area Overlay Zone, building height shall be subject to the requirements of Chapter 21.82 of this code. (2) See Table C in Section 21.45.060 for required setbacks from an arterial street. (3) Building setbacks shall be measured from the outside edge of the required street right-of-way width, whichever is closest to the building. (4) Building setbacks shall be measured from one of the following (whichever is closest to the building): a) the outside edge of the required drive-aisle width; b) the back of sidewalk; or c) the nearest side of a parking bay located contiguous to a drive-aisle (excluding parking located in a driveway in front of a unit’s garage). (5) Any uncovered required parking space in the R-W zone may be located within a required front yard setback and may be tandem. (6) This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code). (7) Protrusions above the height limit shall be allowed pursuant to Section 21.46.020 of this code. Such protrusions include protective barriers for balconies and roof decks. ATTACHMENT NO. 5 CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES Architectural Guideline Compliance Comments Floor Plans and Elevations 1 All residential projects shall be required to have a minimum number of different floor plans, different front and corresponding matching rear elevations with different color schemes as identified below: 2-4 dwelling units shall provide 1 floor plan and 2 different elevations. 5-12 dwelling units shall provide 2 different floor plans and 2 different elevations. 13-20 dwelling units shall provide 2 different floor plans and 3 different elevations. 21+ dwelling units shall provide 3 different floor plans and 3 different elevations. The project consists of two single- family condominium dwellings with two individual floor plans and elevations. Project complies. 2 Every house should have a coherent architectural style. All elevations of a house, including front, side and rear, should have the same design integrity of forms, details and materials. All homes have this consistent design on all elevations. Project complies. 3 In addition to the previous requirements, design details should reinforce and enhance the architectural form and style of every house and differ from other elevations of the same floor plan. A minimum of 4 complimentary design details, including but not limited to those listed below, shall be incorporated into each of the front, rear and street side building façade(s) of the house. Design Details The homes feature multiple balconies and a variety of materials that include stucco, steel cable guardrails, asphalt roof shingles, wood beams, wood trellises, wood columns, wood “knee braces,” and “eyebrow roofs.” Project complies. Balconies Decorative eaves and fascia Exposed roof rafter tails Arched elements Towers Knee braces Dormers Columns Exterior wood elements Accent materials (i.e.; brick, stone, shingles, wood or siding) 4 Floor plans in a project shall exhibit a variety of roof ridges and roof heights within a neighborhood. Each home has a combination of flat, gable, and shed roofs that will provide a variety of roof heights on each of the three dwellings. Project complies. CITY COUNCIL POLICY 44 – NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES Architectural Guideline Compliance Comments Single Story Requirements 9 The remaining total number of homes shall comply with one of the following guidelines: The home shall have a single-story building edge with a depth of not less than 8 feet and shall run the length of the building along one side except for tower elements. The roof covering the single-story element shall incorporate a separate roof plane and shall be substantially lower than the roof for the two-story element. Porches and porte-cochere elements shall qualify as a single-story edge. Houses with courtyards that are a minimum of 15 feet wide located along the side of the house and setback a minimum of 15 feet from the property line are not required to have a single-story building edge. The home shall have a single-story building edge with a depth of not less than 5 feet and shall run the length of the building along one side. The roof of the single-story element shall be substantially lower than the roof for the two-story element of the building. The home shall have a single-story building edge with a depth of not less than 3 feet for 40% of the perimeter of the building. All of the homes are three stories in height and this guideline only addresses two-story single family homes. Each house technically does not meet this guideline. However, the homes meet the purpose and intent of City Council Policy 44 which provides guidelines for homes to be visually interesting, have sufficient building articulation to reduce their bulk and mass, are in scale to their lot size and contribute to the creation of livable neighborhoods. See Section III.C of the staff report for more information. Multiple Building Planes 10 For at least 66% of the homes in a project, there shall be at least 3 separate building planes on street side elevations of lots with 45 feet of street frontage or less and 4 separate building planes on street side elevations of lots with a street frontage greater than 45 feet. Balconies and covered porches qualify as a building plane. The minimum offset in planes shall be 18 inches and shall include, but not be limited to, building walls, windows, porches and roofs. The minimum depth between the faces of the forward-most plane and the rear plane on the front elevation shall be 10 feet. A plane must be a minimum of 30 sq. ft. to receive credit under this section. Each home faces directly to Hemlock Avenue. These elevations have at least 4 separate building planes and comply with this guideline. Project Complies. 11 Rear elevations shall adhere to the same criteria outlined in Number 10 above for front elevations except that the minimum depth between front and back planes on the rear elevation shall be 4 feet. Rear balconies qualify as a building plane. All of the dwellings have at least 4 separate building planes on the rear elevation. Project complies. Windows/Doors 13 At least 66% of exterior openings (door/windows) on every home in the project shall be recessed or projected a minimum of 2 inches and shall be constructed with wood, vinyl or colored aluminum window frames (no mill finishes). All windows will have a 2 inch projection and will be constructed with vinyl. Project complies. 14 Windows shall reinforce and enhance the architectural form and style of the house through, the use of signature windows and varied window shapes and sizes. All of the dwellings provide for multiple window shapes and sizes. Project complies. Front Porches 15 Fifty percent (50%) of the homes shall be designed with a covered front porch, open courtyard, or balcony (each with a minimum depth of 6 feet and a minimum area of 60 square feet) located at the front of the dwelling. The minimum depth for a covered front porch shall be measured from the front façade of the home to the inside of any supporting porch posts. The front and sides of porches shall be open except for required and/or ornamental guardrails. A variety of roof elements shall be provided over porches. Porches may not be converted to living space. 100% of homes comply. Project complies. Front Entries 16 Seventy-five percent (75%) of the homes must have a front entry to the home that is clearly visible from the street. Walkways from the front door to the street are encouraged. Both homes have front entries facing Hemlock Avenue. Chimneys 17 Chimneys and chimney caps shall be in scale with the size of the home. No more than 2 chimneys shall be allowed for homes on lots in planned developments having an area less than 7,500 square feet. No chimneys are proposed. Garage Doors 18 Garage doors for 3 or 4 cars in a row that directly face the street must have a minimum of an 18” plane change between the garage doors after the 2 car garage door. No three or four car garages are proposed. Project complies. Note #1: Fractional units of .5 or greater shall be rounded up to the next whole number and located in a manner to achieve the best project design as determined by the project planner. When a percentage of units are described in the guidelines, the intent is to have that percentage spread throughout the entire project. ATTACHMENT NO. 6 CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS Principle Compliance Comments 1 Building Facades, Front Entries, Porches Facades create interest and character and should be varied and articulated to provide visual interest to pedestrians. Clearly identifiable front doors and porches enhance the street scene and create opportunities for greater social interaction within the neighborhood. Building entries and windows should face the street. Front porches, bay windows, courtyards and balconies are encouraged. The building facades include a variety of roof heights, off-set building projections and interesting materials including stucco, wood columns, wood “knee braces,” “wood trellises,” and stainless steel cable railings that create visual interest to pedestrians. In addition, each home has both a 2nd and 3rd floor deck/balcony facing the street. Project complies. 2 Garages Homes should be designed to feature the residence as the prominent part of the structure in relation to the street. A variety of garage configurations should be used to improve the street scene. This may include tandem garages, side- loaded garages, front-loaded garages, alley-loaded garages and recessed garages. Each dwelling will include a two car garage and one additional parking space for visitors located within each driveway. The project site is not large enough to accommodate a variety of garage configurations such as side located garages. However, each front loaded garage is recessed between 6 – 8 feet. Project complies. 3 Street Design An interconnected, modified (grid) street pattern should be incorporated into project designs when there are no topographic or environmental constraints. Interconnected streets provide pedestrians and automobiles many alternative routes to follow, disperse traffic and reduce the volume of cars on any one street in the neighborhood. Streets should be designed to provide both vehicular and pedestrian connectivity by minimizing the use of cul-de-sacs. The street network should also be designed to create a safer, more comfortable pedestrian and bicycling environment. Local residential streets should have travel and parking lanes, be sufficiently narrow to slow traffic, provide adequate access for emergency and service vehicles and emergency evacuation routes for residents and include parkways with trees to form a pleasing canopy over the street. Local residential streets are the public open space in which children often play and around which neighborhoods interact. Within this context, vehicular movement should be additionally influenced through the use of city-accepted designs for traffic calming measures. The project is developing on an existing multi-family residentially zoned lot on the corner of two existing public streets (Hemlock Avenue & Garfield Street) presently developed as part of an existing interconnected street pattern in the Beach Area Overlay Zone and the existing street design has already been designed. However, the project is conditioned to provide curb and adjacent sidewalk improvements. CITY COUNCIL POLICY 66 – LIVABLE NEIGHBORHOODS (CONTINUED) Principle Compliance Comments 4 Parkways Street trees should be planted in the parkways along all streets. Tree species should be selected to create a unified image for the street, provide an effective canopy, avoid sidewalk damage and minimize water consumption. Queen palms trees are proposed along the project frontage. 5 Pedestrian Walkways Pedestrian walkways should be located along or visible from all streets. Walkways (sidewalks or trails) should provide clear, comfortable and direct access to neighborhood schools, parks/plazas and transit stops. Primary pedestrian routes should be bordered by residential fronts, parks or plazas. Where street connections are not feasible (at the end of cul-de-sacs), pedestrian paths should also be provided. The project has been conditioned to provide for pedestrian circulation in the form of an attached curb and adjacent sidewalk along its frontages on Hemlock Avenue and Garfield Street. Project complies. 6 Centralized Community Recreation Areas Park or plazas, which serve as neighborhood meeting places and as recreational activity centers should be incorporated into all planned unit developments. As frequently as possible, these parks/plazas should be designed for both active and passive uses for residents of all ages and should be centrally located within the project. Parks and plazas should be not be sited on residual parcels, used as buffers from surrounding developments or to separate buildings from streets. The project consists of only two dwelling units and is not required to provide community recreation areas. JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:18:52 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 TITLE SHEET A0.0 GARFIELD CUSTOM BEACH HOMES 3806 Garfield Street, Carlsbad CA 92008 PROJECT TEAM GARFIELD CUSTOM BEACH HOMES SHEET INDEX VICINITY MAP PROJECT DATAFIRE NOTES PROJECT SITE DESCRIPTION 1.ACCESS ROAD MINIMUM DIMENSIONS: FIRE APPARATUS ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED IMPROVED WIDTH OF NOT LESS THAN 24 FEET; CURB LINE TO CURB LINE, AND AN UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAT 13 FEET 6 INCHES. EXCEPTION: SINGLE FAMILY RESIDENTIAL DRIVEWAYS; SERVING NO MORE THAN FOUR SINGLE FAMILY DWELLINGS, SHALL HAVE MINIMUM OF 16 FEET, CURB LINE TO CURB LINE, OF UNOBSTRUCTED IMPROVED WIDTH. ACCESS ROADS SHALL BE DESIGNED AND MAINTAINED TO SUPPORT THE IMPOSED LOADS OF NOT LESS THAN 75,000 POUNDS. 2.RESPONSE MAPS: ANY NEW DEVELOPMENT, WHICH NECESSITATES UPDATING OF EMERGENCY RESPONSE MAPS BY VIRTUE OF NEW STRUCTURES, HYDRANTS, ROADWAYS, OR SIMILAR FEATURES, SHALL BE REQUIRED TO PROVIDE MAP UPDATES IN ONE OF THE FOLLOWING FORMATS (AUTOCAD DWG, DXF, ESRI SHAPEFILE, ESRI PERSONAL GEODATABASE, OR XML FORMAT) AND SHALL BE CHARGED A REASONABLE FEE FOR UPDATING ALL RESPONSE MAPS. 3. CONSTRUCTION MATERIALS: PRIOR TO DELIVERY OF COMBUSTIBLE BUILDING CONSTRUCTION MATERIALS TO THE PROJECT SITE ALL OF THE FOLLOWING CONDITIONS MUST BE COMPLETED TO THE SATISFACTION OF THE FIRE DEPARTMENT: 1) ALL WET AND DRY UTILITIES SHALL BE INSTALLED AND APPROVED BY THE APPROPRIATE INSPECTING DEPARTMENT OF AGENCY; 2) AS A MINIMUM, THE FIRST LIFT OF ASPHALT PAVING SHALL BE IN PLACE TO PROVIDE A PERMANENT ALL WEATHER SURFACE FOR EMERGENCY VEHICLES; AND 3) ALL FIRE HYDRANTS SHALL BE INSTALLED, IN SERVICE AND ACCEPTED BY THE FIRE DEPARTMENT AND APPLICABLE WEATHER DISTRICT. 4.POSTING OR STRIPING ROADWAYS "NO PARKING FIRE LANE": FIRE DEPARTMENT ACCESS ROADWAYS, WHEN REQUIRED, SHALL BE PROPERLY IDENTIFIED AS PER FIRE DEPARTMENT STANDARDS. 5.ADDRESS NUMBERS: APPROVED NUMBERS AND/OR ADDRESSES SHALL BE PLACED ON ALL NEW AND EXISTING BUILDINGS AND AT APPROPRIATE ADDITIONAL LOCATIONS AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY FRONTING THE PROPERTY FROM EITHER DIRECTION OF APPROACH. SAID NUMBERS SHALL CONTRAST FROM THEIR BACKGROUNDS, AND SHALL MEET THE FOLLOWING MINIMUM STANDARDS AS TO SIZE: 4" HIGH WITH A 3/8" STROKE FOR RESIDENTIAL BUILDINGS. ADDITIONAL NUMBERS SHALL BE REQUIRED WHERE DEEMED NECESSARY BY THE FIRE MARSHALL. 6.ADDRESS NUMBERS FOR STRUCTURES LOCATED OFF ROADWAY: WHERE STRUCTURES ARE LOCATED OFF A ROADWAY ON LONG EASEMENTS/DRIVEWAYS, A MONUMENT MARKER SHALL BE PLACED AT THE ENTRANCE WHERE THE EASEMENT/DRIVEWAY INTERSECTS THE MAIN ROADWAY. PERMANENT ADDRESS MARKERS WITH HEIGHT CONFORMING TO FIRE DEPARTMENT STANDARDS SHALL BE AFFIXED TO THIS MARKER. 7.AUTOMATIC FIRE SPRINKLER SYSTEM - ONE AND TWO FAMILY DWELLINGS: STRUCTURES SHALL BE PROTECTED BY AN AUTOMATIC FIRE SPRINKLER SYSTEM DESIGNED AND INSTALLED TO THE SATISFACTION OF THE FIRE DEPARTMENT. PLANS FOR THE AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE APPROVED BY THE FIRE DEPARTMENT PRIOR TO THE ISSUANCE OF BUILDING PERMIT(S). ARCHITECT: SHACKELTON DESIGN GROUP 1106 SECOND STREET, #359 ENCINITAS, CA 92024 760.889.2600 STEVE@SHACARCHITECTURE.COM CIVIL ENGINEER: TYLER LAWSON PASCO LARET SUITER AND ASSOCIATES 535 NORTH HIGHWAY 101, SUITE A SOLANA BEACH, CA 92075 (858)259-8212, TLAWSON@PLSAENGINEERING.COM LANDSCAPE ARCHITECT: JOHN PATTERSON GILLESPIE MOODY PATTERSON, INC. 4010 SORRENTO VALLEY BLVD., SUITE 200 SAN DIEGO, CA 92121 (858)558-8977 JOHN@GMPLANDARCH.COM TITLE 24: DAVID MCCLAIN TITLE 24 DATA CORP 633 MONTEREY TRAIL, PO BOX 2199 FRAZIER PARK, CA 93225-2199 (800)237-8824 TITLE24@FRAZMTN.COM DEVELOPER / BUILDER: RINCON REAL ESTATE GROUP 3005 S EL CAMINO REAL, UNIT 5 SAN CLEMENTE, CA 92672 (949) 438-5494 KDUNN@RINCONGRP.COM TOTAL FLOOR AREA (LIVING SPACE): 5,925 SQ. FT. TOTAL FOOTPRINT AREA: 3,168 SQ. FT. SITE AREA:6,319 S.F. LOT COVERAGE ALLOWED:60% 3,790 S.F. LOT COVERAGE PROPOSED:51% 3168 S.F. OWNER: RREG Investment Series, LLC Series I-012 APPLICANT: Rincon Real Estate Group, Inc. PROJECT SITE: 3806 Garfield Street, Carlsbad, CA 92008 APN: 204-270-04-00 LEGAL DESCRIPTION: LOT 1 IN BLOCK "M" OF PALISADES IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO THE MAP THEREOF NO. 1747, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, FEBRUARY 5, 1923. (AS DESCRIBED IN QUITCLAIM DEED RECORDED IN THE OFFICE OF THE SAN DIEGO COUNTY RECORDER AS DOCUMENT 1994-0496507) ZONING: R-3, BOA RESIDENTIAL HIGH DENSITY (RH) LAND USE: RMH CONSTRUCTION TYPE: V-N, SPRINKLERED FRONT SETBACK: 10'-0" SIDE SETBACK: 5'-0" REAR SETBACK: 10'-0" MAX. HEIGHT: 24' FLAT ROOF, 30' SLOPE ROOF @ 3:12 PITCH HEIGHT: 3 STORIES (30') LANDSCAPE AREA: 1035 SF / 16% PROPOSED UNITS: 2 PROPOSED LOTS: 1 PROPOSED DENSITY: 13.8 DU/AC AVERAGE DAILY TRAFFIC GENERATED: 20 TRIPS (2* 10ADT/DU) WATER DEMAND: 1,650 GPD SEWER GENERATION: 1 EDU/ DU DRAINAGE BASIN: AGUA HEDIONDA/ LOS MONOS PARKING: PROVIDED:2 ENCLOSED PARKING SPACES PER UNIT. SEWER DISTRICT: CITY OF CARLSBAD WATER DISTRICT: CARLSBAD MUNICIPAL WATER DISTRICT SCHOOL DISTRICT: CARLSBAD UNIFIED SCHOOL DISTRICT . 3806 GARFIELD ST. ” ” A0.0 TITLE SHEET A0.2 SITE ELEVATIONS A0.1 SITE PLAN C-1 CIVIL SITE SECTIONS C-2 PRELIMINARY GRADING PLAN A0.3 HOUSE #1 AREA PLANS A0.4 HOUSE #2 AREA PLANS A1-2.1 HOUSE #1 ENTRY LEVEL FLOOR PLAN A1-2.2 HOUSE #1 2ND FLOOR PLAN A1-2.3 HOUSE #1 3RD FLOOR PLAN A1-2.4 HOUSE #1 ROOF PLAN A1-3.1 HOUSE #1 EXTERIOR ELEVATIONS A1-3.2 HOUSE #1 EXTERIOR ELEVATIONS A2-2.1 HOUSE #2 ENTRY LEVEL FLOOR PLAN A2-2.2 HOUSE #2 2ND FLOOR PLAN A2-2.3 HOUSE #2 3RD FLOOR PLAN A2-2.4 HOUSE #2 ROOF PLAN A2-3.1 HOUSE #2 EXTERIOR ELEVATIONS A2-3.2 HOUSE #2 EXTERIOR ELEVATIONS L1 LANDSCAPE CONCEPT PLAN L2 LANDSCAPE AREA PLAN THE PROJECT SCOPE OF WORK WILL INCLUDE GRADING THE SITE AND DROPPING THE NEW FINISH GRADE. A NEW 2’-3’ HIGH PERIMETER RETAINING WALL WILL BE DESIGNED. TWO NEW RESIDENTIAL, AIR SPACE CONDOMINIUMS WILL BE PLANNED. EACH HOME WILL BE THREE STORIES AND SHALL NOT EXCEED 30’ IN HEIGHT. THE THIRD STORY WILL HAVE 3:12 SLOPED ROOFS. EACH HOME WILL HAVE TWO CAR ENCLOSED GARAGES AND PROVIDE TWO TWENTY FOOT DRIVEWAYS TO SATISFY ADDITIONAL PARKING REQUIREMENTS. EACH HOME WILL MEET THE FRONT, SIDE AND REAR YARD SETBACKS. THE UPPER FLOORS WILL HAVE 24” OVER HANGING BALCONIES INTO THE REQUIRED SETBACKS. EACH HOME WILL BE A CUSTOM DESIGN WITH INDIVIDUAL PLANS, ROOFS, MATERIALS AND COLORS. HOUSE #1 LIVING AREA HOUSE #1ENTRY LEVEL FLOOR AREA 835 SF HOUSE #1 SECOND LEVEL FLOOR AREA 1274 SF HOUSE #1 THIRD LEVEL FLOOR AREA 662 SF 2771 SF LOT COVERAGE AND FLOOR AREAS: HOUSE #1 LOT COVERAGE HOUSE #1ENTRY LEVEL FLOOR AREA 835 SF HOUSE #1 GARAGE 517 SF HOUSE #1 SECOND LEVEL OVERHANG 75 SF HOUSE #1 SECOND LEVEL OVERHANG 101 SF 1527 SF HOUSE #1 DECK AREA HOUSE #1 DECK 1 129 SF HOUSE #1 DECK 2 45 SF HOUSE #1 TOP LEVEL DECK 84 SF 258 SF TOTAL LIVING AREA: PRIVATE RECREATION SPACE PROVIDED: 208 SF HOUSE #2 LIVING AREA HOUSE #2 ENTRY LEVEL FLOOR AREA 902 SF HOUSE #2 SECOND LEVEL FLOOR AREA 1484 SF HOUSE #2 THIRD LEVEL FLOOR AREA 768 SF 3154 SF HOUSE #2 LOT COVERAGE HOUSE #2 ENTRY LEVEL FLOOR AREA 902 SF HOUSE #2 GARAGE 511 SF SECOND LEVEL OVERHANG 227 SF 1641 SF PRIVATE RECREATIONAL SPACE PROVIDED: 208 SF HOUSE #2 DECK AREA HOUSE #2 DECK 1 64 SF HOUSE #2 DECK 2 102 SF HOUSE #2 ROOF DECK 105 SF 271 SF TOTAL: TOTAL: TOTAL: TOTAL: TOTAL: Rev Description Date N 56°00'16" E 125.95' S 56°00'08" W 125.93'N 33° 59' 55" W 50.18'S 34° 01' 28" E 50.18'N 56° 00' 16" E 125.95' H E M L O C K A V E. HOUSE #2 PAD = 58.60' F.F. = 59.30' FOOTPRINT = 1413 S.F. HOUSE #1 G A R F I E L D S T R E E TENTRY SYSB5' - 0"F.O. GAR20' - 0"30' P P P P S9 S17 S9 S9 S9 S22 S23SYSB10' - 0"ENTRY PAD = 61.30' F.F. = 62.00' FOOTPRINT = 1352 S.F. GARAGE GARAGE S17 S17 S23 S10 BLD'G SETBACK 11' - 11 7/8" S11 S11 S23 12' - 6 1/2"S20 S20 S4 S4 S13 S13 S13 S3 S21 S7 S18 S18 FYSB 10' - 0"INTERIOR SYSB5' - 0"INTERIOR SYSB5' - 0"2' - 0"S13SYSB10' - 0"SYSB10' - 0"RYSB 10' - 0" 2' - 0"17' - 0"3' - 0"1' - 0"5' - 11 7/8"6' - 0"25'10' - 6"60555658575 9 6061 6263 635958575661626358S18S18 S12 S18 S3 S12S12 S18 S18 10' - 0"PROPERTY LINE CENTERLINE WALL- SEE CIVIL DWGS. 8'-6" X 19'-0" PARKING SPACE SETBACK LINE P FENCE- SEE LANDSCAPE DWGS. JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:18:54 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 SITE PLAN A0.1 GARFIELD CUSTOM BEACH HOMES 1" = 10'-0"1 SITE PLAN NORTH KEYNOTES FOR DRAWINGS S3 CONCRETE WALK- SEE LANDSCAPE DRAWINGS S4 CONCRETE PATIO S7 PROPOSED DEDICATION TO CITY OF CARLSBAD- SEE CIVIL DRAWINGS S9 PROPERTY LINE S10 EXISTING STRUCTURE OUTSIDE OF PROJECT PROPERTY LINE- NOT A PART S11 36" X 48" CONCRETE LEVEL LANDING S12 CONCRETE DRIVEWAY S13 PRIVATE RECREATION SPACE ABOVE- SEE AREA PLANS FOR SQUARE FOOTAGE AND DIMENSIONS S17 WALL PER CIVIL DRAWINGS S18 FENCE- GATE WHERE INDICATED- SEE LANDSCAPE DRAWINGS S20 DIAGONAL HATCH PATTERN INDICATES SECOND LEVEL OVERHANG S21 EXISTING FIRE HYDRANT S22 EXISTING SIDEWALK S23 SETBACK LINE SITE PLAN LEGEND Rev Description Date HOUSE #1 View from Garfield Street looking south JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:19:21 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 SITE ELEVATIONS A0.2 GARFIELD CUSTOM BEACH HOMES 2 SITE PERSPECTIVE 3/16" = 1'-0"1 SITE ELEVATIONS HOUSE #2 Rev Description Date UP DN 835 SF HOUSE #1ENTRY LEVEL FLOOR AREA 517 SF HOUSE #1 GARAGE STAIR LINE OF SECOND LEVEL OVERHANG LINE OF SECOND LEVEL 75 SF HOUSE #1 SECOND LEVEL OVERHANG 101 SF HOUSE #1 SECOND LEVEL OVERHANG 1274 SF HOUSE #1 SECOND LEVEL FLOOR AREA129 SF HOUSE #1 DECK 1 45 SF HOUSE #1 DECK 2 STAIR PRIVATE RECREATION SPACE 125 S.F. 7' - 4"17' - 0"662 SF HOUSE #1 THIRD LEVEL FLOOR AREA 84 SF HOUSE #1 TOP LEVEL DECK OPEN TO BELOW ROOF BELOW ROOF BELOW ROOF BELOW ROOF BELOW ROOF BELOW ROOF BELOW PRIVATE RECREATION SPACE 84 S.F. 6' - 0"14' - 0"JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:19:23 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #1 AREA PLANS A0.3 GARFIELD CUSTOM BEACH HOMES 3/16" = 1'-0"1 HOUSE #1 ENTRY LEVEL FLOOR AREA PLAN HOUSE #1 FLOOR AREA SCHEDULE AREA NAME FLOOR LEVEL AREA (S.F.) HOUSE #1ENTRY LEVEL FLOOR AREA HOUSE 1 ENTRY LEVEL 835 SF HOUSE #1 GARAGE HOUSE 1 ENTRY LEVEL 517 SF HOUSE #1 SECOND LEVEL OVERHANG HOUSE 1 ENTRY LEVEL 75 SF HOUSE #1 SECOND LEVEL OVERHANG HOUSE 1 ENTRY LEVEL 101 SF HOUSE #1 SECOND LEVEL FLOOR AREA HOUSE 1 LEVEL 2 1274 SF HOUSE #1 DECK 1 HOUSE 1 LEVEL 2 129 SF HOUSE #1 DECK 2 HOUSE 1 LEVEL 2 45 SF HOUSE #1 THIRD LEVEL FLOOR AREA HOUSE 1 LEVEL 3 662 SF HOUSE #1 TOP LEVEL DECK HOUSE 1 LEVEL 3 84 SF 3/16" = 1'-0"2 HOUSE #1SECOND LEVEL FLOOR AREA PLAN 3/16" = 1'-0"3 HOUSE #1 THIRD LEVEL FLOOR AREA PLAN ALLOWABLE ROOF DECK AREA TABULATION BUILDING FOOTPRINT: 1353 S.F. SECOND LEVEL OVERHANGS = 174 S.F. TOTAL FOOTPRINT FOR LOT COVERAGE = 1528 S.F. ALLOWABLE TOP LEVEL DECK AREA : 25% OF 1528 S.F. = 382 S.F. ACTUAL TOP LEVEL DECK AREA TOTAL: 84 SF TOTAL PRIVATE RECREATION AREA PROVIDED: 209 S.F. NORTH NORTH NORTH FOOTPRINT = 1352 S.F. Rev Description Date STAIR 902 SF HOUSE #2 ENTRY LEVEL FLOOR AREA 511 SF HOUSE #2 GARAGE LINE OF SECOND LEVEL OVERHANG (226 S.F.) 227 SF SECOND LEVEL OVERHANG 1484 SF HOUSE #2 SECOND LEVEL FLOOR AREA STAIR 64 SF HOUSE #2 DECK 1 ROOF BELOW 102 SF HOUSE #2 DECK 2 105 SF HOUSE #2 ROOF DECK 768 SF HOUSE #2 THIRD LEVEL FLOOR AREA ROOF BELOW ROOF BELOW ROOF BELOW STAIR PRIVATE RECREATION SPACE 103 S.F. PRIVATE RECREATION SPACE 105 S.F. 10' - 4"11'8' - 3 1/2"14' - 0"JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:19:25 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #2 AREA PLANS A0.4 GARFIELD CUSTOM BEACH HOMES 3/16" = 1'-0"1 HOUSE #2 ENTRY LEVEL AREA PLAN HOUSE #2 FLOOR AREA SCHEDULE AREA NAME LEVEL AREA SECOND LEVEL OVERHANG HOUSE 2 ENTRY LEVEL 227 SF HOUSE #2 ENTRY LEVEL FLOOR AREA HOUSE 2 ENTRY LEVEL 902 SF HOUSE #2 GARAGE HOUSE 2 ENTRY LEVEL 511 SF HOUSE #2 SECOND LEVEL FLOOR AREA HOUSE 2 LEVEL 2 1484 SF HOUSE #2 DECK 1 HOUSE 2 LEVEL 2 64 SF HOUSE #2 THIRD LEVEL FLOOR AREA HOUSE 2 LEVEL 3 768 SF HOUSE #2 DECK 2 HOUSE 2 LEVEL 3 102 SF HOUSE #2 ROOF DECK HOUSE 2 LEVEL 3 105 SF 3/16" = 1'-0"2 HOUSE #2 LEVEL 2 AREA PLAN 3/16" = 1'-0"3 HOUSE #2 LEVEL 3 AREA PLAN NORTH ALLOWABLE ROOF DECK AREA TABULATION BUILDING FOOTPRINT: 1413 S.F. SECOND LEVEL OVERHANGS = 230 S.F. TOTAL FOOTPRINT FOR LOT COVERAGE = 1528 S.F. ALLOWABLE TOP LEVEL DECK AREA : 25% OF 1413 S.F. = 353 SF ACTUAL TOP LEVEL DECK AREA TOTAL: 208 S.F. TOTAL PRIVATE RECREATION AREA PROVIDED: 208 S.F. NORTH NORTH FOOTPRINT = 1413 S.F. Rev Description Date 1 A1-3.1 1 A1-3.2 2 A1-3.2 25' - 0"GARAGE STORAGEEQ. BDRM #2 BDRM #3 HALL BATH #1 FLEX SPACE ENTRY LAUNDRY RM 2 A1-3.1 1.A 1.A 1.B 1.B 1.D 1.D 1.E 1.E 1.4 1.4 1.3 1.3 1.5 1.5 1.1 1.1 47' - 0" CLOS.STAIR33' - 6"7 7 D W UP 20 20' - 2 1/2" 20' - 6" 27 21' - 0"53 1.2 1.C 1.C 32 20' - 8 1/2"56 2' - 0"JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:19:26 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #1 ENTRY LEVEL FLOOR PLAN A1-2.1 GARFIELD CUSTOM BEACH HOMESNORTH 1/4" = 1'-0"1 HOUSE #1 ENTRY LEVEL FLOOR PLAN KEYNOTES FOR DRAWINGS 7 LINE OF SECOND FLOOR OVERHANG 20 PARKING SPACE- TYPICAL 27 PAINTED STEEL PIPE COLUMN 32 WOOD TRELLIS ABOVE 53 LINE OF DECK ABOVE 56 LINE OF FLOOR ABOVE Rev Description Date 1 A1-3.1 1 A1-3.2 2 A1-3.2 DECK 7' - 6" DINING ROOM MASTER BATH WIC MASTER BEDROOM HALL CL DECK DECK KITCHEN GREAT ROOM POWDER RM. duct DN 2 A1-3.1 1.A 1.A 1.B 1.B 1.D 1.D 1.E 1.E 1.4 1.4 1.3 1.3 1.5 1.5 1.1 1.1 33' - 6"ISLAND DECK 12' - 0"DECK4' - 0"47' - 0" (PRIVATE RECREATION SPACE) UP56TYP. 56 TYP. 2' - 0" 1.2 PANT. SNACK BAR 1.C 56 56 56 38 732' - 6"1' - 6 1/2"JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:19:27 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #1 2ND FLOOR PLAN A1-2.2 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #1 SECOND FLOOR PLAN NORTH KEYNOTES FOR DRAWINGS 38 WOOD TRELLIS BELOW 56 LINE OF FLOOR ABOVE 73 EYEBROW ROOF- FLAT Rev Description Date 1 A1-3.1 1 A1-3.2 2 A1-3.2 BATH #2 BEDROOM #4 FLEX SPACEDECK 2 A1-3.1 1.A 1.A 1.B 1.B 1.D 1.D 1.E 1.E 1.4 1.4 1.3 1.3 1.5 1.5 1.1 1.1 DECK14' - 0"DECK 6' - 0" WET BAR 15' - 0"45' - 0"18' - 0"(PRIVATE RECREATION SPACE) 3737 3737 3737 37 37 3737 DN OPEN TO BELOW CLOS. 1.2 1' - 6"1.C 50 2' - 0"2' - 4 1/4"2' - 6"JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:19:29 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #1 3RD FLOOR PLAN A1-2.3 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #1 THIRD FLOOR PLAN NORTH KEYNOTES FOR DRAWINGS 37 ROOF BELOW 50 WOOD COLUMN Rev Description Date 1 A1-3.1 1 A1-3.2 2 A1-3.2 2 A1-3.1 1.A 1.A 1.B 1.B 1.D 1.D 1.E 1.E 1.4 1.4 1.3 1.3 1.5 1.5 1.1 1.1 3" / 12"3" / 12"3" / 12"3" / 12"2" / 12" LOW SLOPE ROOF LOW SLOPE ROOF 1/4" / 12"1/4" / 12" 34 34 34 RIDGE RIDGE 22 73 2424 2424 24 2282 8282 55 3' - 0" 1.2 242' - 0"8282 55 1.C 1.C 38 1' - 10"2' - 0"JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:19:30 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #1 ROOF PLAN A1-2.4 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #1 ROOF PLAN NORTH KEYNOTES FOR DRAWINGS 22 ROLL TYPE ROOFING MEMBRANE 24 COMPOSITION ASPHALT SHINGLE ROOFING 34 DECK BELOW 38 WOOD TRELLIS BELOW 55 LINE OF WALL BELOW (TYP.) 73 EYEBROW ROOF- FLAT 82 LOW SLOPED ROOF- CLASS 'A' ICBO 4804 OR EQUAL- B.U. MODIFIED BITUMEN OVER 1/2" 'TECHSHIELD' ALUM. FACED OSB SHEATHING & RAFTERS AS PER STUCTURAL PLAN W/ 5/8" GPW CEILING CEILING PER PLAN- PROVIDE R-21 BATT INSULATION- SLOPE TO DRAIN MIN. 3/8"PER FT. Rev Description Date HOUSE 1 ENTRY LEVEL 0' - 0" HOUSE 1 LEVEL 2 9' - 6" HOUSE 1 LEVEL 3 19' - 0" GRADE -0' - 8 3/8" 24 47 31 41 25 47 48 29 29' - 9"22' - 2 1/2"50 27 49 1 2 (61.3') 2 1 28 30 PORTION OF WALL SEEN AT ANGLE 41 M1-1 M1-2 M1-5 M1-6 M1-2 M1-8 M1-3 M1-8 M1-7 M1-5 M1-9 M1-5 M1-5 25 M1-4 HOUSE 2 ENTRY LEVEL 0' - 0" HOUSE 2 LEVEL 2 9' - 6" HOUSE 2 LEVEL 3 19' - 0" HOUSE 1 ENTRY LEVEL 0' - 0" HOUSE 1 LEVEL 2 9' - 6" HOUSE 1 LEVEL 3 19' - 0" GRADE -0' - 8 3/8" 3" 12"3" 12" 3" 12" 47 31 41 48 25 26 2 29' - 9"1 45 (61.3') 1 2 46 26 M1-2 M1-7 M1-6 M1-3 M1-8 M1-5 M1-5 25M1-4 50M1-5 M1-5 47M1-2 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:20:02 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #1 EXTERIOR ELEVATIONS A1-3.1 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #1 NORTH ELEVATION 1/4" = 1'-0"2 HOUSE #1 WEST ELEVATION KEYNOTES FOR DRAWINGS 1 EXISTING GRADE 2 FINISH GRADE 24 COMPOSITION ASPHALT SHINGLE ROOFING 25 CEMENT STUCCO 26 METAL WALL REGLET/ CONTROL JOINT (TYP.) 27 PAINTED STEEL PIPE COLUMN 28 WOOD BEAM AND TRELLIS 29 PAINTED METAL GARAGE DOOR 30 WOOD KNEE BRACE 31 42" HIGH GUARDRAIL-STAINLESS STEEL CABLE RAIL 41 FACTORY FABRICATED WINDOW & FRAME WITH FRAME CASING- DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 45 GALV. METAL EDGE FLASHING OVER 2 X 4 WD. SHADOW BOARD (TYP.) 46 METAL FLASHING- COLOR TO MATCH ADJACENT SURFACE 47 PAINTED ROOF FASCIA 48 FACTORY FABRICATED DOOR & FRAME WITH DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 49 WOOD BEAM 50 WOOD COLUMN NOTE: ALL WINDOW FRAMES TO BE INSTALLED WITH AN EXTERIOR FRAME CASING EXTENSION TO PROVIDE 2" FRAME PROJECTION OUT FROM THE EXTERIOR FACE OF GLAZING. HOUSE 1 MATERIALS AND COLORS KEYNOTES M1-1 ROOFING SHINGLES- COLOR: 'SAGE' M1-2 ROOF FASCIA PAINT COLOR: 'DRIFTING' M1-3 STUCCO FIELD COLOR: 'CRISP MUSLIN' M1-4 STUCCO ACCENT COLOR: 'ENVY' M1-5 TRIM COLOR: 'DRIFTING' M1-6 STAINLESS STEEL RAILING- FEENEY 'DESIGN RAIL' M1-7 DOOR FRAME, 'BRONZE' M1-8 WINDOW FRAME, 'BRONZE' M1-9 GARAGE DOOR- COLOR: DRIFTING' Rev Description Date HOUSE 1 ENTRY LEVEL 0' - 0" HOUSE 1 LEVEL 2 9' - 6" HOUSE 1 LEVEL 3 19' - 0" GRADE -0' - 8 3/8" 24 47 41 25 26 2 31 47 (61.3') 1 29' - 9"1 2 22' - 2 1/2"262626 2626 73 30 TYP. TYP. M1-1 M1-2 M1-8 M1-3 M1-5 M1-2 M1-1 25 M1-4 M1-6 HOUSE 2 ENTRY LEVEL 0' - 0" HOUSE 2 LEVEL 2 9' - 6" HOUSE 2 LEVEL 3 19' - 0" HOUSE 1 ENTRY LEVEL 0' - 0" HOUSE 1 LEVEL 2 9' - 6" HOUSE 1 LEVEL 3 19' - 0" GRADE -0' - 8 3/8" 3" 12" 3" 12" 24 46 47 41 26 31 48 25 49 50 2 29' - 9"22' - 2 1/2"1 1 (61.3')2 2626 73 30 47 30 28 M1-1 M1-5 M1-6 M1-5 M1-5 M1-2 M1-8 M1-5 M1-5 M1-5 M1-3 25 M1-4 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:20:40 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #1 EXTERIOR ELEVATIONS A1-3.2 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #1 SOUTH ELEVATION 1/4" = 1'-0"2 HOUSE #1 EAST ELEVATION KEYNOTES FOR DRAWINGS 1 EXISTING GRADE 2 FINISH GRADE 24 COMPOSITION ASPHALT SHINGLE ROOFING 25 CEMENT STUCCO 26 METAL WALL REGLET/ CONTROL JOINT (TYP.) 28 WOOD BEAM AND TRELLIS 30 WOOD KNEE BRACE 31 42" HIGH GUARDRAIL-STAINLESS STEEL CABLE RAIL 41 FACTORY FABRICATED WINDOW & FRAME WITH FRAME CASING- DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 46 METAL FLASHING- COLOR TO MATCH ADJACENT SURFACE 47 PAINTED ROOF FASCIA 48 FACTORY FABRICATED DOOR & FRAME WITH DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 49 WOOD BEAM 50 WOOD COLUMN 73 EYEBROW ROOF- FLAT NOTE: ALL WINDOW FRAMES TO BE INSTALLED WITH AN EXTERIOR FRAME CASING EXTENSION TO PROVIDE 2" FRAME PROJECTION OUT FROM THE EXTERIOR FACE OF GLAZING. HOUSE 1 MATERIALS AND COLORS KEYNOTES M1-1 ROOFING SHINGLES- COLOR: 'SAGE' M1-2 ROOF FASCIA PAINT COLOR: 'DRIFTING' M1-3 STUCCO FIELD COLOR: 'CRISP MUSLIN' M1-4 STUCCO ACCENT COLOR: 'ENVY' M1-5 TRIM COLOR: 'DRIFTING' M1-6 STAINLESS STEEL RAILING- FEENEY 'DESIGN RAIL' M1-8 WINDOW FRAME, 'BRONZE' Rev Description Date 2 A2-3.2 1 A2-3.2 1 A2-3.1 2 A2-3.1 21' - 0"35' - 0"25' - 0"2.A 2.A 2.C 2.C2.B 2.D 2.D 2.F 2.F 2.1 2.2 2.2 2.32.3 2.42.4 47' - 0" BATH #1 BDRM #1 BDRM #2 ENTRY GARAGE STORAGE EQ. HALL FLEX SPACE LAUNDRY CLOSET STAIR 20' - 6" 27 7 D W up 20' - 5"20' - 2 1/2" TOILET RM 7 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:20:42 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #2 ENTRY LEVEL FLOOR PLAN A2-2.1 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #2 ENTRY LEVEL FLOOR PLAN NORTH KEYNOTES FOR DRAWINGS 7 LINE OF SECOND FLOOR OVERHANG 27 PAINTED STEEL PIPE COLUMN Rev Description Date 2 A2-3.2 1 A2-3.2 1 A2-3.1 2 A2-3.1 2.A 2.A 2.C 2.C 2.B 2.B 2.D 2.D 2.F 2.F 2.1 2.2 2.2 2.32.3 2.42.4 GREAT RM DINING AREA KITCHEN HALL BDRM #4 MASTER BDRM MASTER BATH WIC DECK REF. SPACEPANT. STAIR UP DN 56 53 56 47' - 0" 37 DW MW BELOW 37 2' - 0"BATH #2 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:20:43 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #2 2ND FLOOR PLAN A2-2.2 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #2 SECOND FLOOR PLAN NORTH KEYNOTES FOR DRAWINGS 37 ROOF BELOW 53 LINE OF DECK ABOVE 56 LINE OF FLOOR ABOVE Rev Description Date 2 A2-3.2 1 A2-3.2 1 A2-3.1 2 A2-3.1 2.A 2.A 2.C 2.C 2.B 2.B 2.D 2.D 2.F 2.F 2.1 2.2 2.2 2.32.3 2.42.4 13' - 5"DECK DECK FLEX SPACE BATH #4 OFFICE BDRM #5 HALL SITTING AREA STAIR DN 8' - 0"11' - 0"10' - 4" up 3737 3737 3737 RECREATION SPACE RECREATION SPACE 37 32' - 0"28' - 0" 35 1' - 6"37 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:20:44 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #2 3RD FLOOR PLAN A2-2.3 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #2 THIRD FLOOR PLAN NORTH KEYNOTES FOR DRAWINGS 35 SKYLIGHT 37 ROOF BELOW Rev Description Date 2 A2-3.2 1 A2-3.2 1 A2-3.1 2 A2-3.1 2.A 2.A 2.C 2.C 2.B 2.B 2.D 2.D 2.F 2.F 2.1 2.2 2.2 2.32.3 2.42.4 3" / 12"3" / 12"3" / 12"3" / 12"2" / 12"3" / 12"RIDGE RIDGEVALLEYV ALLEY 3434 3434 LOW SLOPE ROOF 35 24 2424 24 2424 2424 22 2282 24 55 55 2' - 0" 2' - 0" 2' - 0"2' - 0"1' - 11"3" / 12"34 3" / 12"24 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:20:46 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #2 ROOF PLAN A2-2.4 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #2 ROOF PLAN NORTH KEYNOTES FOR DRAWINGS 22 ROLL TYPE ROOFING MEMBRANE 24 COMPOSITION ASPHALT SHINGLE ROOFING 34 DECK BELOW 35 SKYLIGHT 55 LINE OF WALL BELOW (TYP.) 82 LOW SLOPED ROOF- CLASS 'A' ICBO 4804 OR EQUAL- B.U. MODIFIED BITUMEN OVER 1/2" 'TECHSHIELD' ALUM. FACED OSB SHEATHING & RAFTERS AS PER STUCTURAL PLAN W/ 5/8" GPW CEILING CEILING PER PLAN- PROVIDE R-21 BATT INSULATION- SLOPE TO DRAIN MIN. 3/8"PER FT. Rev Description Date HOUSE 2 ENTRY LEVEL 0' - 0" HOUSE 2 LEVEL 2 9' - 6" HOUSE 2 LEVEL 3 19' - 0" GRADE -0' - 8 3/8" 45 24 47 31 47 41 49 27 29 48 49 25 26 24 45 29' - 9 1/2"3" 12" 3" 12" 2" 12" TYP. 120' - 4 1/2"(58.6') 21 2 PORTION OF WALL SEEN AT ANGLE M2-6 M2-5 M2-2 M2-1 M2-2 M2-8 M2-5 M2-9 M2-7 M2-5 M2-3 25 M2-4 M2-4 M2-1 M2-5 HOUSE 2 ENTRY LEVEL 0' - 0" HOUSE 2 LEVEL 2 9' - 6" HOUSE 2 LEVEL 3 19' - 0" GRADE -0' - 8 3/8"29' - 9 3/4"23' - 6 3/4"24 47 45 3" 12" 3" 12" 3" 12" 24 41 25 2 35 48 31 49 27 49 1 26 (58.6') 1 2 3" 12" M2-1 M2-2 M2-1 M2-2 M2-8 M2-3 M2-6 M2-5 M2-5 25M2-4 48M2-7 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:21:13 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #2 EXTERIOR ELEVATIONS A2-3.1 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #2 NORTH ELEVATION 1/4" = 1'-0"2 HOUSE #2 WEST ELEVATION KEYNOTES FOR DRAWINGS 1 EXISTING GRADE 2 FINISH GRADE 24 COMPOSITION ASPHALT SHINGLE ROOFING 25 CEMENT STUCCO 26 METAL WALL REGLET/ CONTROL JOINT (TYP.) 27 PAINTED STEEL PIPE COLUMN 29 PAINTED METAL GARAGE DOOR 31 42" HIGH GUARDRAIL-STAINLESS STEEL CABLE RAIL 35 SKYLIGHT 41 FACTORY FABRICATED WINDOW & FRAME WITH FRAME CASING- DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 45 GALV. METAL EDGE FLASHING OVER 2 X 4 WD. SHADOW BOARD (TYP.) 47 PAINTED ROOF FASCIA 48 FACTORY FABRICATED DOOR & FRAME WITH DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 49 WOOD BEAM NOTE: ALL WINDOW FRAMES TO BE INSTALLED WITH AN EXTERIOR FRAME CASING EXTENSION TO PROVIDE 2" FRAME PROJECTION OUT FROM THE EXTERIOR FACE OF GLAZING. HOUSE 2 MATERIALS AND COLORS KEYNOTES M2-1 ROOFING SHINGLES- COLOR: 'SAGE' M2-2 ROOF FASCIA PAINT COLOR: 'CHARCOAL SMUDGE' M2-3 STUCCO FIELD COLOR: 'CRISP MUSLIN' M2-4 STUCCO ACCENT COLOR: 'CHARCOAL' M2-5 TRIM COLOR: 'CHARCOAL SMUDGE' M2-6 STAINLESS STEEL RAILING- FEENEY 'DESIGN RAIL M2-7 DOOR FRAME, METALIC GRAY M2-8 WINDOW FRAME, METALIC GRAY M2-9 GARAGE DOOR- COLOR: METALIC GRAY Rev Description Date HOUSE 2 ENTRY LEVEL 0' - 0" HOUSE 2 LEVEL 2 9' - 6" HOUSE 2 LEVEL 3 19' - 0" GRADE -0' - 8 3/8" 3" 12" 3" 12"24 29' - 9 3/4"47 41 26 25 31 35 1 1 (58.6') 22 62 47 24 26 262626 18" RECESS W/ FLAT ROOF M2-2 M2-8 M2-3 M2-1 M2-6 M2-2 M2-1 25 M2-4 HOUSE 2 ENTRY LEVEL 0' - 0" HOUSE 2 LEVEL 2 9' - 6" HOUSE 2 LEVEL 3 19' - 0" HOUSE 1 ENTRY LEVEL 0' - 0" HOUSE 1 LEVEL 2 9' - 6" GRADE -0' - 8 3/8"20' - 4 1/2"24 47 3" 12" 41 25 26 48 2 1 29' - 9 3/4"(58.6') 1 2 49 3" 12" 62 26 26 26 31 M2-6 M2-2 M2-1 M2-3 M2-5 M2-7 M2-1 M2-8 M2-4 JOB NO: DATE: TITLE: PUD 15-17/CDP 15-34 SDP 15-16 /MS 15-11 C:\Users\Rick\Documents\Garfield_11_12_15_Central_Rick.rvt11/23/2015 9:21:42 AM3806 Garfield Street, Carlsbad CA 92008 GARF 11/19/2015 PLANNING 3 HOUSE #2 EXTERIOR ELEVATIONS A2-3.2 GARFIELD CUSTOM BEACH HOMES 1/4" = 1'-0"1 HOUSE #2 SOUTH ELEVATION 1/4" = 1'-0"2 HOUSE #2 EAST ELEVATION KEYNOTES FOR DRAWINGS 1 EXISTING GRADE 2 FINISH GRADE 24 COMPOSITION ASPHALT SHINGLE ROOFING 25 CEMENT STUCCO 26 METAL WALL REGLET/ CONTROL JOINT (TYP.) 31 42" HIGH GUARDRAIL-STAINLESS STEEL CABLE RAIL 35 SKYLIGHT 41 FACTORY FABRICATED WINDOW & FRAME WITH FRAME CASING- DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 47 PAINTED ROOF FASCIA 48 FACTORY FABRICATED DOOR & FRAME WITH DUAL GLAZED LOW-E GLASS- TEMPERED SAFETY GLAZING WHERE INDICATED (TYP.) 49 WOOD BEAM 62 EYEBROW ROOF W/ 3/12 SLOPE NOTE: ALL WINDOW FRAMES TO BE INSTALLED WITH AN EXTERIOR FRAME CASING EXTENSION TO PROVIDE 2" FRAME PROJECTION OUT FROM THE EXTERIOR FACE OF GLAZING. HOUSE 2 MATERIALS AND COLORS KEYNOTES M2-1 ROOFING SHINGLES- COLOR: 'SAGE' M2-2 ROOF FASCIA PAINT COLOR: 'CHARCOAL SMUDGE' M2-3 STUCCO FIELD COLOR: 'CRISP MUSLIN' M2-4 STUCCO ACCENT COLOR: 'CHARCOAL' M2-5 TRIM COLOR: 'CHARCOAL SMUDGE' M2-6 STAINLESS STEEL RAILING- FEENEY 'DESIGN RAIL M2-7 DOOR FRAME, METALIC GRAY M2-8 WINDOW FRAME, METALIC GRAY Rev Description Date