HomeMy WebLinkAbout2017-11-01; Planning Commission; ; CDP 2016-0006 (DEV2016-0061) – MFD-01The City of Carlsbad Planning Division A REPORT TO THE PLANNING COMMISSION
Single Family Coastal Development Permit
Item No.
Application complete date: August 30, 2017
P.C. AGENDA OF:November 1, 2017 Project Planner: Chris Garcia
Project Engineer: David Rick
SUBJECT: CDP 2016-0006 (DEV2016-0061) – MFD-01 – Request for approval of a Coastal
Development Permit to demolish an existing single-family home and construct a four-unit
apartment building on a 0.25-acre infill site located at 2637 Jefferson Street, within the
Mello II Segment of the Local Coastal Program and Local Facilities Management Zone 1.
The project site is not within the appealable area of the California Coastal Commission.
The City Planner has determined that this project is exempt from the requirements of the
California Environmental Quality Act (CEQA) pursuant to Section 15303, “New
Construction or Conversion of Small Structures,” of the State CEQA Guidelines and will
not have any adverse significant impact on the environment.
I.RECOMMENDATION
That the Planning Commission ADOPT Planning Commission Resolution No. 7273 APPROVING Coastal
Development Permit CDP 2016-0006 based upon the findings and subject to the conditions contained
therein.
II.PROJECT DESCRIPTION AND BACKGROUND
The applicant proposes to demolish one existing single-family home and construct a four-unit, multi-
family apartment building on a 0.25-acre infill site within the Mello II Segment of the Local Coastal
Program. Topographically, the site is generally flat with an elevation approximately 57 feet above mean
sea level (MSL). The site is developed with one existing single-family home and does not contain any
sensitive vegetation.
The proposed project contains one, three-story building. The first floor contains four covered parking
spaces and living area for two of the four units. Access to the covered parking is from a single drive-aisle
off of Jefferson Street. The remaining required parking, including guest parking, is provided as five parallel
parking spaces adjacent to the drive-aisle and one parking space to the rear of the building.
Units A and B are located at each end of the building and have entries on the ground floor. These two-
story, 1,144 square foot units contain two bedrooms, one and a half bathrooms, and a small balcony.
Units C and D are located in the middle of the building and have entries on the second floor that are
accessed from an exterior stairway. These two-story, 1,300 square foot units contain two bedrooms, one
and a half bathrooms, and a 466 square foot balcony located above units A and C. A pedestrian walkway
from the street to the front entries is provided along the north side of the property.
The project is designed with modern, contemporary architecture. Building materials include white
smooth finish stucco, lap siding, stone veneer, and decorative metal screens and railings.
2
CDP 2016-0006 (DEV2016-0061) – MFD-01
November 1, 2017
Page 2
Table “A” below includes the General Plan designations, zoning and current land uses of the project site
and surrounding properties.
TABLE A – SITE AND SURROUNDING LAND USE
Location General Plan Designation Zoning Current Land Use
Site
R-23 Residential 15-23 du/ac with
a Growth Management Control
Point (GMCP) of 19 du/ac
Multiple-Family
Residential (R-3) Zone One single-family home
North R-23 Residential 15-23 du/ac R-3 Multi-family residential
South R-23 Residential 15-23 du/ac R-3 One single-family home
East R-15 Residential 8-15 du/ac with a
GMCP of 11.5 du/ac
R-3 Jefferson Street/Multi-
family residential
West R-23 Residential 15-23 du/ac R-3 Multi-family residential
Table “B” below includes the project site’s gross and net acreage, the number of dwelling units allowed
by the General Plan’s Growth Management Control Point (GMCP) density and the proposed project’s
number of dwelling units and density.
TABLE B – PROPOSED DENSITY
Gross Acres Net Acres DUs Allowed at GMCP
Density (19 du/ac)
DUs Proposed and
Project Density
0.25 acres 0.25 acres 5 units 4 units at 16 du/ac
III. ANALYSIS
The project is subject to the following regulations:
A. R-23 Residential General Plan Land Use designation;
B. Multiple-Family Residential (R-3) Zone, (CMC Chapters 21.16,);
C. Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC
Chapter 21.201) and the Coastal Resource Protection Overlay Zone (CMC Chapter 21.203);
D. Inclusionary Housing Ordinance (CMC Chapter 21.85);
E. Growth Management Ordinance (CMC Chapter 21.90) Local Facilities Management Plan Zone 1.
The recommendation for approval of this project was developed by analyzing the project’s consistency
with the applicable regulations and policies. The project’s compliance with each of the above regulations
is discussed in detail in the sections below.
A. R-23 Residential General Plan Land Use Designation
The General Plan Land Use designation for the property is R-23 Residential which allows residential
development at a density range of 15-23 dwelling units per acre (du/ac) with a Growth Management
Control Point (GMCP) of 19 du/ac. The project site has a net developable acreage of 0.25 acres. The
project’s proposed density of 16 du/ac is within the R-23 density range of 15-23 du/ac but is below the R-
23 GMCP of 19 du/ac. At the GMCP, five dwelling units would be permitted on this 0.25 net developable
acre property. However, consistent with Program 3.2 of the city’s certified Housing Element, all of the
dwelling units which were anticipated towards achieving the city’s share of the regional housing needs
that are not utilized by developers in approved projects, will be deposited in the city’s Excess Dwelling
CDP 2016-0006 (DEV2016-0061) – MFD-01
November 1, 2017
Page 3
Unit Bank. Therefore, this four-unit project will deposit one dwelling unit into the Excess Dwelling Unit
Bank. These excess dwelling units are available for allocation to other projects. Accordingly, there is no
net loss of residential unit capacity and there are adequate properties identified in the Housing Element
allowing residential development with a unit capacity adequate to satisfy the city’s share of the regional
housing need.
Lastly, the project complies with the Elements of the General Plan as outlined in Table “C” below:
TABLE C – GENERAL PLAN COMPLIANCE
Element Use, Classification, Goal, Objective or
Program Proposed Uses & Improvements Comply
Land Use Goal 2-G.2
Promote a diversity of compatible land
uses throughout the city, to enable
people to live close to job locations,
adequate and convenient commercial
services, and public support systems
such as transit, parks, schools, and
utilities.
Policy 2-P.1
Maintain consistency between the
General Plan and Title 21 of the
Carlsbad Municipal Code (Zoning
Ordinance and map).
Policy 2-P.8
Do not permit residential development
to exceed the applicable Growth
Management Control Point (GMCP)
density unless certain findings are
made.
The four-unit multi-family residential
project density of 16 dwelling units
per acre is within the R-23 Residential
density range of 15-23 du/ac and
below the GMCP (19 du/ac). The
project will deposit one dwelling unit
into the city’s Excess Dwelling Unit
Bank. Therefore, the project is
consistent with the project site’s
Multiple-Family Residential (R-3)
zoning and the General Plan Land Use
designation of R-23 Residential.
Yes
Mobility Goal 3-G.7
Provide for safe and efficient
movement of goods throughout the
city.
Policy 3-P.5
Require developers to construct or pay
their fair share toward improvements
for all travel modes consistent with the
Mobility Element, the Growth
Management Plan, and specific impacts
associated with their development.
The proposed project has been
designed to meet all of the circulation
requirements, including a single
driveway access point from Jefferson
Street. In addition, the applicant will
be required to pay traffic impact fees
prior to issuance of building permits
that will go toward future road
improvements.
Yes
Public
Safety
Goal 6-G.1
Minimize injury, loss of life, and
damage to property resulting from fire,
flood, hazardous material release, or
seismic disasters.
The proposed structural
improvements will be required to be
designed in conformance with all
seismic design standards. In addition,
the proposed project is consistent
Yes
CDP 2016-0006 (DEV2016-0061) – MFD-01
November 1, 2017
Page 4
Element Use, Classification, Goal, Objective or
Program Proposed Uses & Improvements Comply
Policy 6-P.6
Enforce the requirements of Titles 18,
20, and 21 pertaining to drainage and
flood control when reviewing
applications for building permits and
subdivisions.
Policy 6-P.39
Ensure all new development complies
with all applicable regulations
regarding the provision of public
utilities and facilities.
with all of the applicable fire safety
requirements including fire sprinklers.
Further, the project has been
conditioned to develop and
implement a program of “best
management practices” for the
elimination and reduction of
pollutants which enter into and/or are
transported within storm drainage
facilities.
Noise Goal 5-G.2
Ensure that new development is
compatible with the noise
environment, by continuing to use
potential noise exposure as a criterion
in land use planning.
Policy 5.P.2
Require a noise study analysis be
conducted for all discretionary
development proposals located where
projected noise exposure would be
other than “normally acceptable.”
The project consists of a four-unit
multi-family building. A noise study by
Ldn Consulting, Inc., dated September
14, 2017, was provided. The windows
of each unit will need to be closed to
meet a 45 dB(a) CNEL interior noise
level. Therefore, mechanical
ventilation is required and the project
is conditioned to comply with the
construction requirements of the
aforementioned noise study. The
apartment project does not require
private outdoor recreation areas and
therefore no outdoor attenuation is
required.
Yes
Housing Goal 10-G.2
New housing developed with diversity
of types, prices, tenures, densities, and
location, and in sufficient quantity to
meet the demand of anticipated city
and regional growth.
Policy 10-P.14
Encourage the use of innovative
techniques and designs to promote
energy conservation in residential
development.
The project proposes to demolish one
single-family home and replace it with
four apartments. The four rental units
will provide additional housing that is
desired to meet demand. In addition,
the project is an infill development
that will comply with all applicable
energy and green codes.
Yes
B. Multiple-Family Residential (R-3) Zone
The proposed project is required to comply with all applicable land use and development standards of the
Carlsbad Municipal Code (CMC) including the Multiple-Family Residential (R-3) Zone (CMC Chapter 21.16).
CDP 2016-0006 (DEV2016-0061) – MFD-01
November 1, 2017
Page 5
The four-unit multi-family apartment project meets or exceeds the requirements of the R-3 Zone as
outlined in Table “D” below.
TABLE D – R-3 COMPLIANCE
R-3 Standards Required Proposed Comply
Building Height 35 feet Roof Peak = 34’-9” Yes
Setbacks Interior Side: 10% Lot Width –
7’5”
Rear: 20% Lot Width – 10’4”
Sides: 7’-6”
Rear: 17’-2”
Yes
Lot Coverage 60% 24% Yes
C. Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC
21.201) and the Coastal Resource Protection Overlay Zone (CMC 21.203)
1. Mello II Segment of the Certified Local Coastal Program and all applicable policies
The proposed site is located in the Mello II Segment of the Local Coastal Program (LCP) and is not within
the appealable area of the California Coastal Commission. The project site has an LCP Land Use
designation of R-23 Residential and Zoning of R-3, which are consistent with the city’s General Plan and
Zoning. The project’s consistency with the R-23 General Plan Land Use designation is analyzed in Section
“A,” Table “C” above.
The project consists of a new three-story, four-unit apartment building. The proposed project is
compatible with the surrounding development of multi-family residential structures. The three-story
structure will not obstruct views of the coastline as seen from public lands or the public right-of-way, nor
otherwise damage the visual beauty of the coastal zone. No agricultural uses currently exist on the
previously graded site, nor are there any sensitive resources located on the developable portion of the
site. The proposed project is not located in an area of known geologic instability or flood hazard. Since
the site does not have frontage along the coastline, no public opportunities for coastal shoreline access
are available from the subject site. Furthermore, the residentially designated site is not suited for water-
oriented recreation activities.
2. Coastal Resource Protection Overlay Zone
The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (CMC
Chapter 21.203 of the Zoning Ordinance) in that the project will adhere to the city’s Master Drainage Plan,
Grading Ordinance, Storm Water Ordinance, BMP Design Manual and Jurisdictional Runoff Management
Program (JRMP) to avoid increased urban run-off, pollutants and soil erosion. The subject property does
not include steep slopes (equal to or greater than 25 percent gradient) nor native vegetation. In addition,
the site is not located in an area prone to landslides, or susceptible to accelerated erosion, floods or
liquefaction.
D. Inclusionary Housing Ordinance
Pursuant to Carlsbad Municipal Code Section 21.85.030D.7, the inclusionary housing requirements do not
apply to rental projects where the developer does not obtain direct financial assistance, offset, or any
other incentive or concession of the type specified in density bonus law. The proposed four-unit
apartment project does not meet any of the previously mentioned qualifications and, therefore, is not
subject to affordable housing requirements.
CDP 2016-0006 (DEV2016-0061) – MFD-01
November 1, 2017
Page 6
E.Growth Management
The proposed project is located within Local Facilities Management Zone 1 in the Northwest Quadrant of
the city. The impacts on public facilities created by the project, and its compliance with the adopted
performance standards, are summarized in Table “F” below.
TABLE F – GROWTH MANAGEMENT COMPLIANCE
Standard Impacts Comply
City Administration 14.1 sq. ft. Yes
Library 7.5 sq. ft. Yes
Waste Water Treatment 4 EDU Yes
Parks 0.03 acre Yes
Drainage 0.3 CFS Yes
Circulation 32 ADT Yes
Fire Station No. 1 Yes
Open Space N/A N/A
Schools Carlsbad (E=0.36/M=0.16/HS = 0.2) Yes
Sewer Collection System 4 EDU / 880 GPSD Yes
Water 1,000 GPD Yes
The project proposes four dwelling units, whereas the unit yield at the GMCP of the property is five
dwelling units. The proposed four-unit project is one unit below the Growth Management Control Point
density for this R-23 Residential designated property. Consistent with the General Plan and Policy No. 43,
one dwelling unit will be deposited in the city’s Excess Dwelling Unit Bank.
IV.ENVIRONMENTAL REVIEW
The City Planner has determined that the project belongs to a class of projects that the State Secretary
for Resources has found do not have a significant impact on the environment, and it is therefore
categorically exempt from the requirement for the preparation of environmental documents pursuant to
Section 15303, (New Construction or Conversion of Small Structures) Class 3 Categorical Exemption of the
State CEQA Guidelines which exempts a multi-family residential structure totaling not more than six units
in urbanized areas. In making this determination, the City Planner has found that the exceptions listed in
Section 15300.2 of the state CEQA Guidelines do not apply to this project. A Notice of Exemption will be
filed by the City Planner upon final project approval.
ATTACHMENTS:
1.Planning Commission Resolution No. 7273
2.Location Map
3.Disclosure Statement
4.Reduced Exhibits
5.Full Size Exhibits “A” – “P” dated November 1, 2017
LAGUNA DR JEFFERSON STKNOWLES AV
KREMEYER CRPRIVATE STCABRILLO PLBUENAVISTACRMADIS
O
N
S
T
CDP 2016-0006 (DEV2016-0061)
MFD-01
SITE MAP
SITE
E
L
C
AMINO
RE
A
LLA COSTA AV
A L G A R DCARLSBAD
B
L
ATTACHMENT 2
c·cityof Carlsbad DISCLOSURE STATEMENT
P- 1{A)
Development Services
Planning Division
1635 Faraday Avenue
(760)602-4610
www .ca rlsbadca .gov
Applicant's statement or disclosure of certain ownership interests on all applications which will
require discretionary action on the part of the City Council or any appointed Board, Commission
or Committee.
The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print.
Note: Person is defined as "Any individual, firm, co-partnership, joint venture, association, social club, fraternal organization, corporation, estate, trust, receiver, syndicate, in this and any other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit."
Agents may sign this document; however, the legal name and entity of the applicant and property owner must be provided below.
1.APPLICANT (Not the applicant's agent)Provide the COMPLETE, LEGAL names and addresses of ALL persons having a
financial interest in the application. If the applicant includes a corporation or partnership,
include the names, titles, addresses of all individuals owning more than 10% of theshares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASEINDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned
corporation, include the names, titles, and addresses of the corporate officers. (A
separate page may be attached if necessary.)
P Miguel Reyes c /P rt erson___________ orp a ___________ _
Title Agent Title --------------
Address 4152 Iowa St. #7 Address ------------San Diego, CA 92104 2.OWNER (Not the owner's agent)
P-1(A)
Provide the COMPLETE, LEGAL names and addresses of ALL persons having anyownership interest in the property involved. Also, provide the nature of the legal
ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the
ownership includes a corporation or partnership, include the names, titles, addresses ofall individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORETHAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE
SPACE BELOW. If a publicly-owned corporation, include the names, titles, and
addresses of the corporate officers. (A separate page may be attached if necessary.)
P Jose Luis Arellano erson___________ Corp/Part. ___________ _
Title Owner Title --------------
Address 835 Ladybug Lane Address -------------
San Marcos, CA 92069
Page 1 of 2 Revised 07/10
ATTACHMENT 3
3. NON-PROFIT ORGANIZATION OR TRUST
If any person identified pursuant to (1) or (2) above is a nonprofit organization or a trust,
list the names and addresses of ANY person serving as an officer or director of the non-
profit organization or as trustee or beneficiary of the.
Non Profit/Trust NIA Non ProfitfTrust __ N_I_A ______ _
Title ------------Title --------------
Address Address ----------------------
4. Have you had more than $500 worth of business transacted with any member of City
staff, Boards, Commissions, Committees and/or Council within the past twelve (12)
months?
D Yes 00 No If yes, please indicate person(s): __________ _
NOTE: Attach additional sheets if necessary.
Jose Luis Arellano Jose Luis Arellano
Print or type name of owner Print or type name of applicant
k
Signature of owner/applicant's agent if applicable/date
Miguel Reyes
Print or type name of owner/applicant's agent
P-1(A) Page 2 of 2 Revised 07/10
vicinity map:Knowles Laguna Dr.Kremeyer SITEJefferson Davis 1011i1i1A1011A101A1011111SectionSection Sheet Detail:Detail Sheet Elevation:Elevation Sheet Door Wall Type Window Spot Elevationdrawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006T1Title SheetArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 920081.This project shall comply with the 2013 California Building Code that adopts the 2012 IBC, 2012 UMC, 2012 UPCand 2011 NEC.2.All dimensions are to face of stud, concrete or masonry, unless otherwise noted on drawings.3.Contractor shall bring to the attention of the design office any conflict, discrepancy or ambiguity in the contractdocuments and shall not proceed with any of the work effected thereby until clarification is given by the designer.4.Contractor shall comply with all OSHA requirements. An OSHA permit is required for the proposed basement.5.If historic grid pattern of sidewalks is damaged during construction, the sidewalk shall be replaced in kind.6.Tempered glass shall be permanently identified and visible when the unit is glazed.7.All windows are to have labels attached by N.F.R.C. showing compliance with energy standards.8.All showerheads for all shower fixtures shall be certified as having a maximum flow rate of no more than 2.0 gpmper CGC 4.303.1.9.All lavatory and kitchen faucets shall be fitted with aflow-restricting aerator with a certified, maximum flow rate ofno more than 1.5 gpm for lavatory faucets and 1.8 gpm for kitchen faucets per CGC 4.303.1.10.All water closets and associated flushometer valves, if any, shall be certified as using no more than 1.28 gallonsper flush and shall meet the performance standards established by the American National Standards InstituteStandard A112.19.2.11.Penetrations of fire-resistive walls, floor-ceilings and roof-ceilings shall be protected as required in IBC Section714.12.A miminum of 50% of construction waste and demolition debris is to be recycled and/or salvaged per CGC4.408.1.13.City will void all designed structural lumber if ripped.14.Only low volume drip or bubbler emitters shall be used to irrigate existing or proposed non-turf, outsidelandscaping.15.The contractor responsible for the construction of the seismic-force-resisting system shall submit a writtenStatement of Responsibility to the building official prior to the commencement of work on the system.16.Contractor is to provide an operation and maintenance manual for the owner at the time of final inspection perCGC 4.410.1.17.VOC's must comply with the limitations listed in CGC Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC Section 4.504.2.18.Prior to final approval, Contractor will complete and sign the Green Building Standards Certification form to befiled with the building department official.19.The moisture content of wood shall not exceed 19% before it is enclosed in construction. Buildings materials withvisible signs of water damage should not be used in construction. The moisture content shall be verified by thecontractor by one of 3 methods specified under CGC 4.505.3.20.An automatic residential fire sprinkler system shall be installed per CBC R313.2.21.Plans shall be provided and approved by the City Engineer that show site grading and provide for storm waterretention and drainage during construction. BMP's that are currently enforced by the city engineer must beimplemented prior to initial inspection by the building department per CGC 4.506.1.22.Underground all existing, proposed and future utilities to the site.23.Contractor shall submit a Construction Waste Management Plan to the jurisdictional agency that regulates wastemanagement, per CGC 4.408.2.24.Concrete slabs will be provided with a capillary break. CGC 4.505.2.1.25.Compliance with the documentation requirements of the 2013 Energy Efficiency Standards is necessary for thisproject. Registered, signed, and dated copies of the appropriate CF1R, CF2R, and CF3R forms shall be madeavailable at necessary intervals for Building Inspector review. Final completed forms will be available for thebuilding owner.26.During construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC4.504.1general notes:Project Directory:Owner:Jose Luis & Maria Elena Arellano, Trustees835 Ladybug Lane San Marcos, CA 92118p 619.980.6006Project Architect:ohms CollaborativeHector AramburoCA Lic. # C-36303536 Sears AvenueSan Diego, CA 92114p 619.517.8881h@ohmsarchitects.comCivil Engineer:Victor Rodriguez-Fernandez1283 E Main St., Suite 109El Cajon, CA 92021Landscape Architect:Greg Hebert Landscape Architect3153 Third AvenueSan Diego, CA 92103p 619.283.5083Contractor: TBDProject Information:Project Description:The scope of work includes the construction of a new three-story 4 unit apartment building over private carports at 2637 Jefferson St.Assessor's Parcel Number: 155-170-25-00Construction Type: V B - Wood Frame Occupancy Classification: R2 (Apartments)/ U/ S1 (Private Car port /Storage); Non-separatedAutomatic Fire Sprinklers: YesStories: ThreeHeight: 35'-0" (max)Carlsbad Parcel Zoning: R-3General Plan: R-23Planned Developement: 16 DU/ACRELot Area: 11,100 sq.ft.Lot Acreage: .25 acreLot Coverage: Structural Coverage 2,671 sq.ft. (24.1%)Parking:Required/Provided Spaces: 10 (4 enclosed/5 uncovered/1 uncovered ADA parking space)Traffic Generation:4 Apts x 6 ADT/Unit = 24 ADTWater District:CMWDSewer District:CarlsbadSchool District:CarlsbadWater Demand:250 GPDx4 Units = 1,000 GPDSewer Demand:4 EDU'sADJ.AdjacentA.F.F.Above Finish FloorALUM.AluminumALT.AlternateARCH.ArchitecturalAVG.AverageBD.BoardBDLG.BuildingBLKG.BlockingBM.BeamBTWN.BetweenCA.TV.Cable TelevisionCBCCalifornia Building CodeC.I.P.Cast-In-Place ConcreteC.J.Control JointCLG.CeilingCLR.ClearC.M.U.Concrete Masonry UnitCOL.ColumnCONC.ConcreteCONT.ContinuousCPTCarpetC.T.Ceramic TileCTR.CenterC.W.Cold WaterD.F.Douglas FirDIA.DiameterDIM.DimensionD.L.Dead LoadDNDownDWG.DrawingEA.EachE.I.F.SExterior Insulation Finish SystemE.J.Expansion JointELEC.ElectricalELEV.ElevationE.O.S.Edge of SlabEQ.EqualEQUIP.EquipmentEXT.ExteriorF.C.U.Fan Coil UnitF.D.Floor DrainFDN.Foundationarchitectural abbreviations:INCL.Included/IncludingINFO.InformationINSUL.InsulationINT.InteriorLAV.LavatoryLB.PoundL.F.Linear FootL.L.Live LoadMAX.MaximumMECH.MechanicalMFR.ManufacturerMICROMicrowaveMIN.MinimumMISC.MiscellaneousMTL.MetalN/ANot ApplicableNO.NumberN.T.S.Not To ScaleO.C.On CenterP.C.F.Pounds Per Cubic FootPERF.PerforatedP.L.F.Pounds Per Linear FootPLY.PlywoodP.S.F.Pounds Per Square FootP.S.I.Pounds Per Square InchP.T.Pressure TreatedRAGReturn Air GrilleREF.ReferenceREFR.RefrigeratorREQ'D.RequiredREV.RevisionRM.RoomR.O.Rough OpeningSECT.SectionS.F.Square FootSHWR.ShowerSIM.SimilarSPECSSpecificationsSQ.SquareS.S.Stainless SteelSTD.StandardSTL.SteelSUSP.SuspendedSYS.SystemTEL.TelephoneT.O.C.Top Of ConcreteTHK.ThicknessT.O.B.Top Of BeamT.O.S.Top Of SlabT.O.W.Top Of WallTYP.TypicalUBCUniform Building CodeU.O.N.Unless Otherwise NotedV.I.F.Verify In FieldVNR.VeneerV.A.Vinyl TileW/WithW.C.Water ClosetWD.WoodW/DWasher/DryerW/OWithoutWP.WaterproofWT.Weightsymbols:F.E.Fire ExtinguisherF.F.Finish FloorFLR.FloorF.O.Face ofF.O.CFace of ConcreteF.O.MFace of MasonryF.O.SFace of StudFP.FireplaceFRMG.FramingFTG.FootingG.GasGA.GaugeGALV.GalvanizedG.C.General ContractorG.F.I.Ground Fault InterrupterGL.GlassHDR.HeaderHGR.HangerHORIZ.HorizontalHT.HeightHTG.HeatingHVAC.Heating/Ventilating/Air ConditioningH.W.Hot Waterdeferred submittals:NOTE*: Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official.1) Automatic Fire Sprinklersagency approval stamps:Building Department Information:Unit C:1st Level 672 sq.ft.2nd Level 627 sq.ft.Unit C TOTAL: 1,299 sq.ft.Terrace 466 sq.ft.Unit D:1st Level 672 sq.ft.2nd Level 627 sq.ft.Unit D TOTAL: 1,299 sq.ft.Balconies: 466 sq.ft.Sheet Index Project TotalsConditioned Area:1st Level 1,094 sq.ft.2nd Level2,538 sq.ft.3rd Level1,254 sq.ft.Conditioned Area Total: 4,886 sq.ft.Car Port 1,054 sq.ft. Utility/Storage 181 sq. ft.Porch: 250 sq.ft.Balconies 90 sq.ft.Terrace 932 sq.ft.Unit AreaUnit A:1st Level 547 sq.ft.2nd Level 597 sq.ft.Conditioned Area: 1,144 sq.ft.Covered Front Porch: 45 sq.ft.Balconies: 45 sq.ft.Unit B:1st Level 547 sq.ft.2nd Level 597 sq.ft.Conditioned Area: 1,144 sq.ft.Covered Front Porch: 205 sq.ft.Balconies: 45 sq.ft.T1 Title SheetTR Turning RadiusC-1 SurveyC-2 Drainage PlanL-1 Conceptual Landscape PlanL-2 Conceptual Landscape Details/WeloL-3 Water Concervation PlanL-4 Water Use PlanA1 3D RendersA2 Plot Plan / Site PlanA3 First Floor PlanA4 Second Floor PlanA5 Third Floor / Roof PlanA6 Building ElevationsA7 Building ElevationsA8 Building Sectionsrevision date notes1 04/11/2017 2nd Submittal2 08/03/2017 3rd SubmittalATTACHMENT 4
30°60°90°120°150°180°24ftMin Radius
(Outer Wheel)15.293ftMin Radius(Inner Wheel)25.902ftMin Radius(Outer Body)14.379ftMax Kickout 0.254ftVehicle Tracking V17.00.1705(20160301) (c) Autodesk, Inc. www.Autodesk.comTitle:P - Passenger CarNotes:Turn(s) based upon a design speed of 5.00mph.PLPLPLPLP - Passenger CarPorchPROPOSED4-Unit ApartmentComplexPROPOSED4-Unit ApartmentComplexStorage/UtilityareaFIRST FLOOR FF ELEV: 58.2'FIRST FLOOR FF ELEV: 58.2'10x20parkingarea10x20parkingarea10x20parkingarea10x20parkingareaGM GM GM GMElectricalPanelsWM WM WM WMWH#1WHWHWHHeat Pump #1Heat Pump #2#2#3#4CommunicationPanelwalkwaysidewalk (e)10x24parkingareaJEFFERSON STREET10x24parking10x24areaarea10x24parkingparkingarea10x24areaparkingsidewalk (e)PorchTrashenclosure150.0'150.0'74.0'74.0'UPPLPLPLPLparkingareaparkingGMElectricalPorchPROPOSED4-Unit ApartmentComplexPROPOSED4-Unit ApartmentComplexStorage/UtilityareaFIRST FLOOR FF ELEV: 58.2'FIRST FLOOR FF ELEV: 58.2'10x20parkingarea10x20parkingarea10x2010x20areaGM GM GMPanelsWM WM WM WMWH#1WHWHWHHeat Pump #1Heat Pump #2#2#3#4CommunicationPanelwalkwayTrashenclosuresidewalk (e)10x24parkingareaJEFFERSON STREET10x24parking10x24areaarea10x24parkingparkingareasidewalk (e)Porch9x20areaparkingP - Passenger Car150.0'150.0'74.0'74.0'UPPLPLPLPLparkingareaparkingGMElectricalPorchPROPOSED4-Unit ApartmentComplexPROPOSED4-Unit ApartmentComplexStorage/UtilityareaFIRST FLOOR FF ELEV: 58.2'FIRST FLOOR FF ELEV: 58.2'10x20parkingarea10x20parkingarea10x2010x20areaGM GM GMPanelsWM WM WM WMWH#1WHWHWHHeat Pump #1Heat Pump #2#2#3#4CommunicationPanelwalkwaysidewalk (e)10x24parkingareaJEFFERSON STREET10x24parkingarea10x24parkingarea10x24areaparkingsidewalk (e)Porch9x20areaparkingTrashenclosureP - Passenger Car150.0'150.0'74.0'74.0'UPdrawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006TRTurning RadiusArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 3/32" = 1'-0"1ADA Parking Turning Radius 3/32" = 1'-0"2End Parking Turning Radius 3/32" = 1'-0"3Typical Parking Turning Radiusrevision date notes
03-02
03-01
03-01
25' SITE VISIBILITY TRIANGLE,
NO LANDSCAPE ELEMENTS OVER
30" HT. IN THIS ZONE
03-01
03-01
EX PALM EX PALM 25'
25'
45°
25'
25'
EX. RETAINING WALL
EXISTING PALMS (2)
TO BE REMOVED,
18" CALIPER
REM. CS
EXISTING TREE
TO BE REMOVED,
12" CALIPER
PL 150.0'PL74.0'PL74.0'PROPOSED
4-Unit Apartment
Complex
PROPOSED
4-Unit Apartment
Complex
JEFFERSON STREETPL 150.0'
walkway
(n) Curb cut andsidewalk per City
of CarlsbadStandarsds(SDRSD G-14)
Trashenclosure 10x24parkingarea
CL
CL
CL
9'-0"8'-0"
10x24parking
10x24
areaarea
10x24parking parkingarea
10x24
areaparking
(n) Curb cut andsidewalk per Cityof CarlsbadStandarsds(SDRSD G-14)
(e) Curb
sidewalk (e)6'-0"24'-0"
20'-0"
FYS
Porch
Unit D
PrivateParking
LivingRoom
Kitchen
Pdr.
Dining
W/D
1/2"1/4"
W/DDining
LivingRoom
Kitchen
ADA Pdr.
Ref.Ref.
Pantry
WH#1
Heat Pump #2
Heat Pump #1
WH#2
WH#3
WH#4
Laundry
Unit BStorage
Unit DStorage
Unit CStorage
Unit AStorage
Laundry
JanetorialStorage
GM GM GM GM ElectricalPanels
WM WM WM WM CommunicationPanel
UP 7'-5"SYS7'-5"SYS14'-10"
RYS
Unit B
PrivateParking
Unit C
PrivateParking
Unit A
PrivateParking
20'-0"
(e) Water Meter
Porch
30'
ROW
4'
INSTALL ROOT BARRIER, TYP.
ADJACENT TO SIDEWALK
4'
4'
4'4'
03-03
03-03
03-02
03-02
PROPOSED 6' HIGH WOODEN FENCE
PROPOSED 6' HIGH
WOODEN FENCE
PROPOSED 6' HIGH WOODEN FENCE
ALONG PROPERTY LINE,
SEE FENCE DETAIL "A", SHEET L-2.
INSTALL ROOT BARRIER, TYP.
ADJACENT TO SIDEWALK
6'
7'-11"
4'
EX PALM
EXISTING PALM
TO BE REMOVED,
12" CALIPER
REM. PA
PROPOSED BIORETENTION SECTION "B"
UNLINED, FOR TREATMENT ONLY
IN HYDROLOGIC SOIL GROUP "D".
EXISTING TREE
TO BE REMOVED,
12" CALIPER
EX. RETAINING WALL
PROPOSED 6' HIGH
WOODEN FENCE
PROPOSED 6' HIGH WOODEN FENCE
ALONG PROPERTY LINE,
SEE FENCE DETAIL "A", SHEET L-2.
3'3'-6" WOOD FENCE ALONG
PROPERTY LINE WITHIN
FRONT YARD SETBACK,
SEE FENCE DETAIL "B",
SHEET L-2.
3'-6" WOOD FENCE ALONG
PROPERTY LINE WITHIN
FRONT YARD SETBACK, SEE
FENCE DETAIL "B", SHEET L-2.
LANDSCAPE AREA PROVIDED IN THE PARKING AREA:
A MINIMUM OF 3% OF THE LANDSCAPE SHALL BE
LANDSCAPED.
PARKING AREA AND DRIVE AISLES: 5,049 SQ.FT.
LANDSCAPE AREA: 664 SQ.FT.
REQUIRED 3% = 152 SQ.FT.
664 / 5,049 x 100 = 13% PROVIDED
7'
8'-5"
25' SITE VISIBILITY TRIANGLE,
NO LANDSCAPE ELEMENTS OVER
30" HT. IN THIS ZONE
RVWD BY:OTHER APPROVAL
INITIALDATE
SHEET SHEETS
APPROVED:
DWN BY:
CHKD BY:PROJECT NO. DRAWING NO.DATE INITIAL
DESIGNER OF WORK
DATE INITIAL
CITY APPROVALREVISION DESCRIPTION
PLANNING
15-764NS*
SEECLI C
FOTEAT Date
C A L
Renewal Date *NIAROIFHI
T
TCELDSNA ADC
A
REP
Signature
3/31/2019GREGORY J .HEBERT
-
3
932GHLA
GHGHLA
4
PLOT DATE: 6/1/17NORTH
0 feet16
1" = 8'-0"
8 24 32
03 PAVING
SYMBOL DESCRIPTION QTY
PROPOSED CONCRETE PAVING, 2,319 SF
DAVIS COLOR: TBD
FINISH: TOP CAST #3
PROPOSED PERMEABLE PAVERS, 3,738 SFMANUF: TBD
CONTACT: TBD
PROPOSED PATIO TILE,221 SF
MANUF: TBD
CONTACT: TBD
03-01
03-02
03-03
REFERENCE NOTES SCHEDULE
MAINTENANCE PLAN
THE PROPERTY OWNER OR LEASEE IS RESPONSIBLE FOR MAINTAINING THE LANDSCAPE, IN A HEALTHY, DISEASE FREE
CONDITIION.
A. PLANTING AREA MAINTENANCE
1. PRUNE TREES AND SHRUBS DURING DORMANCY OR BEFORE NEW GROWTH IN SPRING.
2. MAINTENANCE SHALL INCLUDE WATERING, WEEDING, TIGHTENING AND REPAIRING OF GUY WIRES, RESETTING
PLANTS TO PROPER GRADES OR UPRIGHT POSITION AND REMOVAL OF ALL DEAD MATERIALS.
3. REPLACE DEAD TREES AND SHRUBS.
4. FERTILIZE ACCORDING TO ATTACHED SOIL REPORT.
5. MONITOR PLANTS FOR DISEASE AND PESTS ROUTINELY. HAVE PLANT SAMPLE ANALYZED BY REPUTABLE NURSERY
FOR RECOMMENDATION ON COURSE OF TREATMENT.
6. USE HAND SOIL PROBE TO ANALYZE SOIL MOISTURE LEVELS IN PLANTING BEDS TO MONITOR WET AND DRY
PLANTING AREAS AND TO OBSERVE PLANT ROOT DEPTH AND DEVELOPMENT TO EVALUATE PROPER FUNCTIONING
OF IRRIGATION CONTROLLER.
7. CULTIVATE PLANTING AREAS AND REMOVE WEEDS BY HAND PRIOR TO WEEDS SETTING SEED TO AVOID SPREADING.
8. MULCH PLANTING BEDS ROUTINELY TO MAINTAIN A MINIMUM UNIFORM 3" LAYER.
B. IRRIGATION SYSTEM MAINTENANCE
1. PERFORM ROUTINE MAINTENANCE ON IRRIGATION SYSTEM TO ENSURE MAXIMUM WATER EFFICIENCY AND UNIFORM
COVERAGE.
2. INSPECT DRIP SYSTEM ON A REGULAR BASIS TO REPAIR ANY DAMAGED EQUIPMENT.
3. MONITOR AMOUNTS OF WATER APPLIED TO PLANTING AREAS TO CONFIRM THAT CONTROLLER AND WEATHER
SENSOR EQUIPMENT IS PROPERLY WORKING. NOTIFY HOMEOWNER IF CONTROLLER AND/OR WEATHER STATION
EQUIPMENT NEEDS SERVICING OR REPLACEMENT.
4. OBSERVE ROUTINELY AND IDENTIFY ANY SOIL AND PLANT CONDITIONS FOR HEALTH ISSUES SUCH AS STRESS. USE
THE "FINE-TUNE" WATERING ADJUSTMENT FEATURE ON THE CONTROLLER TO ADJUST THE RUN TIMES BY ZONE.
“I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION
PLANS CONTAINED IN THE CITY OF CARLSBAD’S LANDSCAPE MANUAL AND
WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN
IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL
AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING
CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS
THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER."
NOTES:
1. ALL EXISTING WOODY PLANT MATERIAL TO BE REMOVED.
2. NON-BIODEGRADABLE ROOT BARRIERS SHALL BE INSTALLED BETWEEN ALL NEW STREET
TREES PLACED WITHIN 5 FEET OF PUBLIC IMPROVEMENT INCLUDING WALKS, CURBS, OR
STREET PAVEMENT OR WHERE NEW PUBLIC IMPROVEMENTS ARE PLACED ADJACENT TOEXISTING TREE. DO NOT WRAP BARRIER AROUND THE ROOT BALL.
3. POSITIVE SURFACE DRAINAGE (2% GRADE IN PLANTING AREAS) AWAY FROM STRUCTURESAND TERMINATING IN AN APPROVED DRAINAGE SYSTEM.
4. ONLY SUBSURFACE IRRIGATION SHALL BE USED TO IRRIGATE ANY VEGETATION WITHINTWENTY-FOUR INCHES OF AN IMPERMEABLE SURFACE UNLESS THE ADJACENT
IMPERMEABLE SURFACES ARE DESIGNED AND CONSTRUCTED TO CAUSE WATER TO DRAIN
ENTIRELY INTO A LANDSCAPED AREA.
5. 50% OF THE SHRUBS (EXCEPT ON SLOPES 3:1 OR STEEPER) SHALL BE A MINIMUM 5 GALLON
SIZE.
6. SEE PROPOSED PERIMETER FENCE DETAIL "A", SHEET L-2.
7. ALL PLANTING BEDS TO HAVE MINIMUM UNIFORM 3" BARK MULCH LAYER.
STREET TREE LOCATION REQUIREMENTS:
STREET TREES SHALL BE LOCATED:1. A MIN. OF SEVEN (7) FEET FROM ANY UNDERGROUND UTILITY
2. IN AREAS THAT DO NOT CONFLICT WITH PUBLIC UTILITIES
3. OUTSIDE OF SIGHT DISTANCE AREAS
4. INSIDE THE PUBLIC RIGHT OF WAY, UNLESS APPROVED OTHERWISE BY THE CITY.
5. TREES PLANTED WITHIN FIVE (5) FEET OF THE PUBLIC SIDEWALKS OR OTHER
HARDSCAPE SHALL BE INSTALLED WITH ROOT BARRIERS APPROVED BY THE CITY.
EXISTING TREES QTY BOTANICAL NAME / COMMON NAME CONT
1 CITRUS SPECIES / CITRUS EXISTING
TO BE REMOVED. 12" CALIPER
1 PERSEA AMERICANA / AVOCADO EXISTING
TO BE REMOVED. 12" CALIPER
3 SYAGRUS ROMANZOFFIANUM / QUEEN PALM EXISTING
TO BE REMOVED. 12" CALIPER
REM. CS
REM. PA
EX PALM
EXISTING TREE SCHEDULE
STREET TREES: (100% 24" BOX)2
INSTALL WITH ROOT BARRIER ADJACENT TO SIDEWALKS
WUCOLS-PLANT FACTOR: MODERATE (0.5)
LOPHOSTEMON CONFERTUS / BRISBANE BOX
QUERCUS ILEX / HOLLY OAK
PARKING LOT & SCREENING TREES: (100% 15 GALLON)4
WUCOLS-PLANT FACTOR: LOW (0.3)
ACACIA PENDULA / WEEPING MYALL
ACACIA STENOPHYLLA / SHOESTRING ACACIA
ARBUTUS X `MARINA` / ARBUTUS STANDARD
CALLISTEMON CITRINUS / LEMON BOTTLEBRUSH
LAURUS NOBILIS / SWEET BAY
RHUS LANCEA / AFRICAN SUMAC
SMALL FEATURE TREE (100% 15 GALLON)5
WUCOLS-PLANT FACTOR: LOW (0.3)
ALOE BARBERAE / TREE ALOE
CORDYLINE AUSTRALIS / GRASS PALM
EUPHORBIA INGENS / CANDELABRA TREE
MELALEUCA ELLIPTICA / HONEY MYRTLE
SHRUBS-SCREENING (50% 15 GAL & 50% 5 GAL)79
WUCOLS-PLANT FACTOR: LOW (0.3)
NOTE: APPROXIMATELY 50% OF THE SPECIES TO BE PLANTED ALONG THE
NORTH AND SOUTH PROPERTY LINES WILL BE PLANTINGS THAT WILL REACH A
MINIMUM 20` HEIGHT.
ACACIA LONGIFOLIA / GOLDEN WATTLE
ACCA SELLOWIANA / PINEAPPLE GUAVA, FEIJOA
CALLISTEMON CITRINUS / LEMON BOTTLEBRUSH
CUPRESSUS SEMPERVIRENS `TINY TOWER` TM / TINY TOWER ITALIAN CYPRESS
HAKEA SUAVEOLENS / SWEET HAKEA
JUNIPERUS CHINENSIS `COLUMNARIS` / JUNIPER
THEVETIA PERUVIANA / YELLOW OLEANDER
SHRUBS-MEDIUM: (50% 5 GAL, 50% 1 GAL)20
WUCOLS-PLANT FACTOR: LOW (0.3)
EUPHORBIA CHARACIAS `HUMPTY DUMPTY` / EVERGREEN SPURGE
GREVILLEA X `ROBYN GORDON` / ROBYN GORDON GREVILLEA
LEUCADENDRON X `SAFARI SUNSET` / CONEBUSH
MAHONIA X `SOFT CARESS` / MAHONIA `SOFT CARESS`
ROSMARINUS OFFICINALIS `COLLINGWOOD INGRAM` / ROSEMARY
SHRUBS-LOW: (50% 5 GAL & 50% 1 GAL)47
WUCOLS-PLANT FACTOR: LOW (0.3)
CARISSA MACROCARPA `GREEN CARPET` / GREEN CARPET NATAL PLUM
GREVILLEA LANIGERA `COASTAL GEM` / COASTAL GEM GREVILLEA
LANTANA X `NEW GOLD` / NEW GOLD LANTANA
SUCCULENTS-MEDIUM: (15% 10 GAL & 85% 1 GAL)19
WUCOLS-PLANT FACTOR: LOW TO VERY LOW (.03)
AGAVE ATTENUATA / AGAVE
CRASSULA ARBORESCENS / SILVER DOLLAR PLANT
CRASSULA ARGENTEA / JADE PLANT
DASYLIRION LONGISSIMUM / TOOTHLESS DESERT SPOON
DASYLIRION WHEELERI / GREY DESERT SPOON
EUPHORBIA MAURITANICA
SUCCULENTS-SMALL ACCENTS: (50% 5 GAL & 50% 1 GAL)24
WUCOLS-PLANT FACTOR: LOW TO VERY LOW (0.3)
AEONIUM ARBOREUM / TREE AEONIUM
AEONIUM ARBOREUM `ZWARTKOP` / BLACK ROSE AEONIUM
AEONIUM X `CABERNET` / CABERNET AEONIUM
AGAVE X `BLUE GLOW` / BLUE GLOW AGAVE
CALANDRINIA SPECTABILIS / PINK CALANDRINIA
EUPHORBIA CHARACIAS `HUMPTY DUMPTY` / EVERGREEN SPURGE
EUPHORBIA MAURITANICA
EUPHORBIA RESINIFERA / RESIN SPURGE
YUCCA WHIPPLEI / CHAPARRAL YUCCA
ORNAMENTAL GRASSES (70% 4" POT & 30% 1 GALLON)83
WUCOLS-PLANT FACTOR: LOW (0.3)
(NOTE: PLANTINGS IN SITE VISIBILITY TRIANGLE ZONE
TO BE NO MORE THAN 30" HT.)
FESTUCA MAIREI / ATLAS FESCUE
FESTUCA OVINA GLAUCA `ELIJAH BLUE` / BLUE FESCUE
MUHLENBERGIA RIGENS / DEER GRASS
VINES (100% 5 GAL)3
WUCOLS-PLANT FACTOR: LOW (0.3)
BOUGAINVILLEA SPECIES / BOUGAINVILLEA
HARDENBERGIA VIOLACEA / LILAC VINE
MACFADYENA UNGUIS-CATI / YELLOW TRUMPET VINE
BMP (BIORETENTION) PLANTING 52 SF
WUCOLS-PLANT FACTOR: MODERATE (0.5)
CAREX PRAEGRACILIS / SLENDER SEDGE
JUNCUS PATENS / CALIFORNIA GRAY RUSH
LEYMUS CONDENSATUS `CANYON PRINCE` / NATIVE BLUE RYE
MUHLENBERGIA RIGENS / DEER GRASS
CONCEPT PLANT SCHEDULE
L-1
1
RVWD BY:
INITIALDATE
SHEET SHEETS
APPROVED:
DWN BY:
CHKD BY:PROJECT NO. DRAWING NO.DATE INITIAL
DESIGNER OF WORK
DATE INITIAL
CITY APPROVALREVISION DESCRIPTION 15-764
*
Date
Renewal Date *
Signature
3/31/2019
4
“I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION
PLANS CONTAINED IN THE CITY OF CARLSBAD’S LANDSCAPE MANUAL AND
WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN
IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL
AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING
CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS
THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER."L-2
2
CONC. FOOTING
f'c = 2,500 PSI
12" Ø x 24" DEEP
2'
3"
3'-6"
MAX.
1x6 SPACED PT
OR REDWOOD
BOARDS
HSS 2x2x14 POSTS
PROVIDE 3" OF
LOOSE GRAVEL
AT BASE OF
FOOTING
PROPOSED 3'-6" HIGH PERIMETER WOODEN FENCE
1/2" = 1'-0"
FINISH GRADE
6'
CONC. FOOTING
f'c = 2,500 PSI
12" Ø x 24" DEEP
HSS 2x2x14 POSTS
3'-6"
MAX.
1x6 SPACED PT
OR REDWOOD
BOARDS
SIDE VIEW ELEVATION VIEW
NOTE:
3'-6" WOOD FENCE ALONG
PROPERTY LINE WITHIN
FRONT YARD SETBACK.
P-AR-02BPROPOSED 6' HIGH PERIMETER WOODEN FENCE
1/2" = 1'-0"
CONC. FOOTING
f'c = 2,500 PSI
12" Ø x 24" DEEP
2'
3"
6'
1x6 SPACED PT
OR REDWOOD
BOARDS
HSS 2x2x14 POSTS
PROVIDE 3" OF
LOOSE GRAVEL
AT BASE OF
FOOTING
FINISH GRADE
6'
CONC. FOOTING
f'c = 2,500 PSI
12" Ø x 24" DEEP
HSS 2x2x14 POSTS
6'
1x6 SPACED PT
OR REDWOOD
BOARDS
SIDE VIEW ELEVATION VIEW
P-AR-03A
PL 150.0'74.0'74.0'PROPOSED
4-Unit Apartment
Complex
PROPOSED
4-Unit Apartment
Complex
JEFFERSON STREETPL 150.0'
walkway
(n) Curb cut and
sidewalk per Cityof CarlsbadStandarsds
(SDRSD G-14)
Trashenclosure 10x24parkingarea
CL
CL
CL
9'-0"8'-0"
10x24parking
10x24
areaarea
10x24parking parkingarea
10x24
areaparking
(n) Curb cut andsidewalk per City
of CarlsbadStandarsds(SDRSD G-14)
(e) Curb
sidewalk (e)6'-0"24'-0"20'-0"FYS
Porch
Unit D
Private
Parking
LivingRoom
Kitchen
Pdr.
Dining
W/D
1/2"1/4"
W/DDining
LivingRoom
Kitchen
ADA Pdr.
Ref.Ref.
Pantry
WH#1
Heat Pump #2
Heat Pump #1
WH#2
WH#3
WH#4
Laundry
Unit BStorage
Unit DStorage
Unit CStorage
Unit AStorage
Laundry
JanetorialStorage
GM GM GM GM
ElectricalPanels
WM WM WM WM CommunicationPanel
UP 7'-5"SYS7'-5"SYS14'-10"RYS
Unit B
Private
Parking
Unit C
Private
Parking
Unit A
Private
Parking
20'-0"
(e) Water Meter
Porch
PROPOSED DEDICATED
METER "FOR IRRIGATION
ONLY". EXISTING POTABLE WATER.
RVWD BY:
INITIALDATE
SHEET SHEETS
APPROVED:
DWN BY:
CHKD BY:PROJECT NO. DRAWING NO.DATE INITIAL
DESIGNER OF WORK
DATE INITIAL
CITY APPROVALREVISION DESCRIPTION 15-764
*
Date
Renewal Date *
Signature
3/31/2019
4
NOTE:
1. "IRRIGATION: AN AUTOMATIC, ELECTRONICALLY CONTROLLED IRRIGATION SYSTEM SHALL BE
PROVIDED AS REQUIRED FOR PROPER IRRIGATION, DEVELOPMENT, AND MAINTENANCE OF
THE VEGETATION IN A HEALTHY, DISEASE-RESISTANT CONDITION. THE DESIGN OF THE
SYSTEM SHALL PROVIDE ADEQUATE SUPPORT FOR THE VEGETATION SELECTED." PROPOSED
IRRIGATION TO BE MICRO-SPRAY HEADS FOR TURF, AND DRIP TUBING FOR PLANTING AREAS.
2. SEE SHEET L-2 FOR WATER EFFICIENT LANDSCAPE WORKSHEETS.
•RESIDENTS OF SINGLE-FAMILY HOMES WITH ADDRESSES ENDING IN AN EVEN NUMBER MAY
WATER ON MONDAY, WEDNESDAY AND SATURDAY;
•RESIDENTS OF SINGLE-FAMILY HOMES WITH ADDRESSES ENDING IN AN ODD NUMBER MAY
WATER ON TUESDAY, THURSDAY AND SUNDAY;
•APARTMENT COMPLEXES, CONDOMINIUMS AND BUSINESSES MAY WATER ON MONDAY,
WEDNESDAY AND FRIDAY;
•IRRIGATION IS PERMITTED BETWEEN 10 P.M. AND 6 A.M.; AND
WATERING IS LIMITED TO A MAXIMUM OF 10 MINUTES PER IRRIGATION STATION.
1.PLANTING FOR WATER EFFICIENT LANDSCAPES
•ALL PLANTS SHALL BE GROUPED IN HYDROZONES AND THE IRRIGATION SHALL BE DESIGNED TO DELIVER WATER TO
HYDROZONES BASED ON THE MOISTURE REQUIREMENTS OF THE PLANT GROUPING.
•A HYDROZONE MAY MIX PLANTS OF MODERATE AND LOW WATER USE OR MIX PLANTS OF HIGH WATER USE WITH
PLANTS OF MODERATE WATER USE.
•NO HIGH WATER USE PLANTS SHALL BE ALLOWED IN A LOW WATER USE HYDROZONE.
2. SOIL PREPARATION AND MULCHING
•PRIOR TO PLANTING OF ANY MATERIALS, COMPACTED SOILS SHALL BE TRANSFORMED TO A FRIABLE CONDITION.
ON ENGINEERED SLOPES, ONLY AMENDED PLANTING HOLES NEED MEET THE REQUIREMENT OF THIS SECTION.
•SOIL AMENDMENTS SHALL BE INCORPORATED ACCORDING TO THE RECOMMENDATIONS OF THE SOIL ANALYSIS
REPORT AND WHAT IS APPROPRIATE FOR THE PLANTS SELECTED.
•LANDSCAPE INSTALLATIONS SHALL INCORPORATE COMPOST AT A RATE OF A MINIMUM FOUR CUBIC YARDS PER
1,000 SQUARE FEET OF PERMEABLE AREA TO A DEPTH OF SIX INCHES INTO THE SOIL. SOIL WITH GREATER THAN
6% ORGANIC MATTER IN THE TOP 6 INCHES OF SOIL IS EXEMPT FROM THE REQUIREMENT OF THIS SECTION.
•THE APPLICATION OF ORGANIC MULCH MATERIALS MADE FROM RECYCLED OR POST-CONSUMER MATERIALS SHALL
TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLESS RECYCLED OR POST-CONSUMER ORGANIC PRODUCTS
ARE NOT LOCALLY AVAILABLE.
•A MINIMUM THREE (3) INCH LAYER OF MULCH SHALL BE APPLIED ON ALL EXPOSED SOIL SURFACES IN EACH
LANDSCAPED AREA EXCEPT IN TURFGRASS AREAS, DIRECT SEEDING APPLICATIONS, OR EROSION CONTROL
PLANTINGS WHERE MULCH IS NOT RECOMMENDED. TO PROVIDE HABITAT FOR BENEFICIAL INSECTS AND OTHER
WILDLIFE, UP TO 5% OF THE LANDSCAPE AREA MAY BE LEFT WITHOUT MULCH. DESIGNATED INSECT OR WILDLIFE
HABITAT MUST BE INCLUDED IN THE LANDSCAPE DESIGN PLAN.
•THE MULCH THICKNESS MAY TAPER DOWN TO ONE (1) INCH THICK IN AREAS ADJACENT TO HARD SURFACES SUCH
AS SIDEWALKS CURBS, OR DRIVES WHERE THE DIFFERENCE BETWEEN THE FINISH GRADE AND TOP OF THE HARD
SURFACE IS LESS THAN THREE (3) INCHES. MULCH MAY ALSO TAPER DOWN TO ONE (1) INCH ADJACENT TO TREES,
SHRUBS AND GROUND COVER PLANTINGS.
•IMPERVIOUS MATERIALS SHALL NOT BE PLACED UNDER THE MULCH.
•HIGHLY FLAMMABLE MULCH MATERIAL SHALL NOT BE USED.
•THE MULCHING PORTION OF SEED/MULCH SLURRY IN HYDRO-SEEDED APPLICATIONS THAT MEET CURRENT
ENGINEERING STANDARDS, SATISFIES THE MULCHING REQUIREMENT OF THIS SECTION.
3. FOUNTAINS AND/OR WATER FEATURES
•FOUNTAINS AND/OR WATER FEATURES SHALL HAVE RECIRCULATING SYSTEMS AND SHALL BE DESIGNED TO
MINIMIZE EVAPORATIVE LOSS.
•FOUNTAINS, DECORATIVE POOLS AND PONDS SHALL UTILIZE RECYCLED WATER IF AVAILABLE OR SHALL BE
DESIGNED TO UTILIZE RECYCLED WATER SO THAT IT CAN BE UTILIZED WHEN IT BECOMES AVAILABLE. THE DESIGN
AND EQUIPMENT SHALL CONFORM TO STATE OR LOCAL WATER AND HEALTH AGENCY REQUIREMENTS RELATED TO
RECYCLED WATER.
•USE OF RECYCLED WATER IN FOUNTAINS OR WATER FEATURES IS SUBJECT TO APPROVAL BY THE SAN DIEGO
COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH OR CALIFORNIA DEPARTMENT OF PUBLIC HEALTH.
4. PRACTICAL TURFGRASS AREAS
•LIMIT THE USE OF TURFGRASS TO REDUCE MAINTENANCE AND WATERING COSTS
•DESIGN TURFGRASS AREAS FOR PRACTICAL PURPOSES SUCH AS PLAY AREAS.
5. EFFICIENT IRRIGATION
•WATER DEEPLY AND INFREQUENTLY TO DEVELOP DEEP ROOT SYSTEMS.
•WATER IN THE EVENING OR EARLY MORNING TO REDUCE WATER LOSS DUE TO EVAPORATION.
•ADJUST YOUR CONTROLLER MONTHLY TO ACCOMMODATE CHANGING WEATHER CONDITIONS.
•INSTALL RAIN-SENSOR DEVICES THAT AUTOMATICALLY SHUT OFF IRRIGATION DURING RAIN EVENTS.
•ADJUST IRRIGATION SYSTEMS TO ELIMINATE RUNOFF, LOW HEAD DRAINAGE AND OVERSPRAY.
6. APPROPRIATE MAINTENANCE
•USE ORGANIC FERTILIZERS AND COMPOSTING TO IMPROVE SOIL TEXTURE.
•REPLACE MULCH AS IT DECOMPOSES.
•OCCASIONAL PRUNING OF TREES AND SHRUBS TO REMOVE DEAD STEMS PROMOTES BLOOMING AND CONTROLS
HEIGHT/SPREAD.
•AERATE TURFGRASS AREAS IN THE SPRING AND FALL..
•REGULARLY INSPECT, MAINTAIN AND ADJUST IRRIGATION SYSTEMS.
WATER CONSERVATION REQUIREMENTS
WATER USE RESTRICTION
NORTH
0 feet16
1" = 8'-0"
8 24 32
“I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION
PLANS CONTAINED IN THE CITY OF CARLSBAD’S LANDSCAPE MANUAL AND
WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN
IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL
AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING
CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS
THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER."L-3
3
SYMBOL NOTES QTY
IRRIGATED LANDSCAPED AREA 2,336 SF
HYDROZONE 1 2,188 SF
LOW WATER USE, PLANT FACTOR 0.3, DRIP IRRIGATION
HYDROZONE 2 148 SF
MODERATE WATER USE, PLANT FACTOR 0.5, DRIP IRRIGATION
HYDROZONE SCHEDULE
PL150.0'74.0'74.0'PROPOSED
4-Unit Apartment
Complex
PROPOSED
4-Unit Apartment
Complex
JEFFERSON STREETPL 150.0'
walkway
(n) Curb cut andsidewalk per Cityof CarlsbadStandarsds(SDRSD G-14)
Trashenclosure 10x24parkingarea
CL
CL
CL
9'-0"8'-0"
10x24parking
10x24
areaarea
10x24
parking parkingarea
10x24
areaparking
(n) Curb cut andsidewalk per Cityof CarlsbadStandarsds(SDRSD G-14)
(e) Curb
sidewalk (e)6'-0"24'-0"
20'-0"FYS
Porch
Unit D
Private
Parking
LivingRoom
Kitchen
Pdr.
Dining
W/D
1/2"1/4"
W/DDining
LivingRoom
Kitchen
ADA Pdr.
Ref.Ref.
Pantry
WH#1
Heat Pump #2
Heat Pump #1
WH#2
WH#3
WH#4
Laundry
Unit BStorage
Unit DStorage
Unit CStorage
Unit AStorage
Laundry
JanetorialStorage
GM GM GM GM
ElectricalPanels
WM WM WM WM CommunicationPanel
UP 7'-5"SYS7'-5"SYS14'-10"RYS
Unit B
Private
Parking
Unit C
Private
Parking
Unit A
Private
Parking
20'-0"
(e) Water Meter
Porch
PROPOSED DEDICATED
METER "FOR IRRIGATION
ONLY". EXISTING POTABLE WATER.
RVWD BY:
INITIALDATE
SHEET SHEETS
APPROVED:
DWN BY:
CHKD BY:PROJECT NO. DRAWING NO.DATE INITIAL
DESIGNER OF WORK
DATE INITIAL
CITY APPROVALREVISION DESCRIPTION 15-764
*
Date
Renewal Date *
Signature
3/31/2019
4
NOTE:
1. "IRRIGATION: AN AUTOMATIC, ELECTRONICALLY CONTROLLED IRRIGATION SYSTEM SHALL BE
PROVIDED AS REQUIRED FOR PROPER IRRIGATION, DEVELOPMENT, AND MAINTENANCE OF
THE VEGETATION IN A HEALTHY, DISEASE-RESISTANT CONDITION. THE DESIGN OF THE
SYSTEM SHALL PROVIDE ADEQUATE SUPPORT FOR THE VEGETATION SELECTED." PROPOSED
IRRIGATION TO BE MICRO-SPRAY HEADS FOR TURF, AND DRIP TUBING FOR PLANTING AREAS.
•RESIDENTS OF SINGLE-FAMILY HOMES WITH ADDRESSES ENDING IN AN EVEN NUMBER MAY
WATER ON MONDAY, WEDNESDAY AND SATURDAY;
•RESIDENTS OF SINGLE-FAMILY HOMES WITH ADDRESSES ENDING IN AN ODD NUMBER MAY
WATER ON TUESDAY, THURSDAY AND SUNDAY;
•APARTMENT COMPLEXES, CONDOMINIUMS AND BUSINESSES MAY WATER ON MONDAY,
WEDNESDAY AND FRIDAY;
•IRRIGATION IS PERMITTED BETWEEN 10 P.M. AND 6 A.M.; AND
WATERING IS LIMITED TO A MAXIMUM OF 10 MINUTES PER IRRIGATION STATION.
WATER USE RESTRICTION
NORTH
0 feet16
1" = 8'-0"
8 24 32
“I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION
PLANS CONTAINED IN THE CITY OF CARLSBAD’S LANDSCAPE MANUAL AND
WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN
IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL
AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING
CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS
THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER."L-4
4
SYMBOL NOTES QTY
POTABLE WATER USE 2,336 SF
PROPOSED AREAS ARE TO REMAIN POTABLE WATER USE,
PRIVATELY MAINTAINED BACK YARD/PATIO.
SITE_DEVELOPMENT
drawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A13D RendersArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008View 2View 1View 3revision date notes
UPUPwalkwa(e) Curb Drive FYSB20'-0"SYSB7'-5"SYSB7'-5"RYSB14'-10"PorchPorch(e) Water Meter; To be replace per plumbing drawings spec's PL150.0'PL150.0'PL74.0'Trash EnclosurePROPOSED 4-Unit ApartmentComplexOutline of second story aboveJEFFERSON STREETsidewalk (e)F.O.S11'-2 3/4"F.O.S17'-2"F.O.S13'-0 3/4"F.O.S20'-1 1/2"10x24parking area10x24parking area10x24parking area10x24parking area10x24parking areaADA parkingOutline of balcony aboveFIRST FLOOR FF ELEV: 58.2'F.O.S7'-6"(n) Curb cut and sidewalk per City of Carlsbad Standarsds (SDRSD G-14)Proposed pedestrian access easement4'-9 1/4"30" CMU wall30" CMU wallCLCLCL9x20parking area8'Aisle20'-0"PROPOSED 4-Unit ApartmentComplexFIRST FLOOR FF ELEV: 58.2'10x20parking area10x20parking area10x20parking area10x20parking area6' Wood fence at PL perimeter5'-7 1/2"6' Max.trash enclosurePL74.0'GM GM GM GMVertically aligned, surface mounted, electrical panels; Per electrical specs.Location of gas metersElectrical PanelsWM WM WM WMHorizontally aligned, flush mounted, cold water meter; Per Plumbing specs.WHWHWHWHHeat Pump #1Heat Pump #2Communication Panel24'-1 1/4"42" Max. height Wood fence at PL within front yard set backRetaining wall below; See C-2 for more infoLegendConcretePermeable Conc.LandscapingTile/ Natural StonePavers (permeable)walkwa(e) Curb Drive SYSB7'-5"PorchPorch(e) Water Meter; To be replace per plumbing drawings spec's PL150.0'PL150.0'PL74.0'Trash EnclosurePROPOSED 4-Unit ApartmentComplexOutline of second story aboveJEFFERSON STREETsidewalk (e)10x24parking area10x24parking area10x24parking area10x24parking area10x24parking areaFIRST FLOOR FF ELEV: 58.2'(n) Curb cut and sidewalk per City of Carlsbad Standarsds (SDRSD G-14)Proposed pedestrian access easementCLCLCL9x20parking area8'AislePROPOSED 4-Unit ApartmentComplexFIRST FLOOR FF ELEV: 58.2'10x20parking area10x20parking area10x20parking area10x20parking area6' Wood fence at PL perimeterPL74.0'GM GM GM GMElectrical PanelsWM WM WM WMWHWHWHWHHeat Pump #1Heat Pump #2Communication Panel4'-0" 2'-0"drawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A2Plot Plan / Site PlanArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 1/8" = 1'-0"1Plot Plan 1/8" = 1'-0"2Site Planrevision date notes01624328GRAPHIC SCALE
UPA61A7A7A62123'-9 3/4"6'-1 1/2"2'-8 1/2"3'-9"11'-2"1'-0 3/4"10'-0"2'-4"10'-0"10'-9 1/2"10'-0"2'-4"10'-0"1'-0 3/4"11'-5 1/2"3'-5 1/2"2'-8 1/2"6'-5"3'-6 1/4"9'-11 1/4"92'-9 3/4"9'-11 1/4"112'-8 1/2"92.42°92.42°3'-1 1/4"3'-1 1/4"Unit APrivateParkingUnit CPrivateParkingUnit DPrivateParkingUnit BPrivateParkingLivingRoomKitchenPdr.Dining3'-2 3/4"5'-0 1/2"8'-4 3/4"4'-3 3/4"5'-0"8'-3 1/4"12'-8 1/2"25'-11 3/4"3'-2 3/4"5'-0 1/2"8'-4 3/4"4'-3 3/4"8'-3 1/4"12'-8 1/2"5'-0"25'-11 3/4"3'-6 1/4"4'-11 1/4"19'-1 1/4"3'-0 3/4"8'-0"2'-4"9'-0"2'-2"8'-2 1/4"2'-5 1/2"9'-0"2'-4"8'-0"3'-0 3/4"19'-1 1/4"4'-7 3/4"3'-9 3/4"27'-6 3/4"57'-7"27'-6 3/4"112'-8 1/2"CoveredPorch1A8Egress2A83A8Outline of floor aboveEgressRecess for TV aboveStair treads and risers; See detail .36" H handrail; See detail .R @7 1/2"181/2"1/4"1'-8"4'-10"----24'-6 3/4"20'-4"24'-6 3/4"20'-5 3/4"4'-4 1/4"4'-1 3/4"4'-2"3'-7"4'-0 3/4"DiningLivingRoomKitchenADA Pdr.Ref.Ref.10 3/4"PantryWH#11'-6"1'-2"4'-6 3/4"Heat Pump #2Heat Pump #1WH#2WH#3WH#42'-6"LaubdryUnit BStorageUnit DStorageUnit CStorageUnit AStorageLaundryDJanetorial StorageElectric Fireplace; see spec 10-1 for add. infoHigh WindowCeiling: 9'-0"Ceiling: 9'-0"Ceiling: 9'-0"Ceiling: 9'-0"Ceiling: 9'-10"Ceiling: 9'-10"Unit AUnit BCoveredParkingCoveredParkingdrawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A3First Floor PlanArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 1/4" = 1'-0"1First Floor PlanSee detail 9/A10for 1 hr rated ceiling at garageBuilding Area:Unit A:1st Level 547 sq.ft.Covered Front Porch: 45 sq.ft.Unit B:1st Level 547 sq.ft.Front Porch: 205 sq.ft.Storage:Unit A 29 sq.ft.Unit B 33 sq.ft.Unit C 27 sq.ft.Unit D 37 sq.ft.Utility/Storage 56 sq. ft.Car Port1,054 sq.ft.0812164GRAPHIC SCALEBuilding Key:revision date notes
UPDNDNA61A711A82A83A85'-5 3/4"13'-7 1/2"4'-9"5'-2 1/4"8"11'-7 1/4"6'-7 1/2"5'-2 1/4"5'-0 1/2"8"12'-11 1/2"5'-5 3/4"8'-5 1/2"8'-5 1/2"19'-1 1/4"57'-7"19'-1 1/4"112'-8 1/2"5'-0"12'-8 1/2"8'-3 1/4"25'-11 3/4"92.42°16'-11 1/2"8"12'-6 3/4"3'-1 1/4"12'-9 1/2"8"12'-6"3'-1 1/4"12'-10 1/4"8"16'-11 1/2"2'-8 1/4"7'-3"8'-3 1/4"17'-8 1/2"25'-11 3/4"112'-8 1/2"2'-8 1/4"7'-3"HallwayBedroom 1Bedroom 2Bedroom1BathBedroom2HallwayHallwayLaundryLaundryBathBedroom 2Bedroom 1Bedroom 2Bedroom 1BathHallway1'-10"--A72A62EQEQSlope 1/4"/ft.Slope 1/4"/ft.Slope 1/8"/ft.BathOpen to belowDN6'-7 1/2"11'-10 3/4"BBA2'-6"3'-6"3'-7"R @7 1/2"18R @7 1/2"18Open to belowClosetClosetClosetCeiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Ceiling: 9'-10"Unit BUnit AUnit CUnit Ddrawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A4Second Floor PlanArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 1/4" = 1'-0"1Second Floor PlanBuilding Key:Building Area:Unit A:2nd Level 597 sq.ft.Balcony 45 sq.ft.Unit B:2nd Level 597 sq.ft.Balcony 45 sq.ft.Unit C:1st Level 672 sq.ft.Unit D:1st Level 672 sq.ft.0812164GRAPHIC SCALErevision date notes
DN1A82A83A86'-8 3/4"22'-4 3/4"8"22'-4 3/4"6'-8 3/4"58'-11"29'-1 1/2"8"29'-1 1/2"58'-11"17'-2 3/4"3'-8 1/4"20'-11"EQEQRef.Ref.PantryPantryStorageStorageA72A62A71A61Slope 1/4"/ft.Slope 1/4"/ft.17'-2 3/4"3'-8 1/4"20'-11"2'-6"2'-6"1'-0"Slope 1/8"/ft.Slope 1/8"/ft.Slope 1/8"/ft.Slope 1/8"/ft.Heat Pump #3Heat Pump #4DiningPdr.DiningPdr.LivingKitchenKitchenLivingTerraceTerrace1'-0"92.42°92.42°1'-7"2nd floor walls belowSlope to drain2'-5 1/4"11 1/2"Ceiling: 10'-0"Ceiling: 10'-0"Roof material: GAF Everguard TPO 60 mil single ply roofing membrane. Color T.B.D.; Install per manufacturer's specifications; TYP at roofs other than roof deck;Class A rated per ICC# ESR-1597; See specsSlope 1/4"/ft.3" Overflow drainSlope 1/4"/ft.3" Overflow drainSlope 1/4"/ft.Outline of floor belowOutline of floor below3" Overflow drainSlope 1/4"/ft.6" Parapet Unit CUnit Ddrawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A5Third Floor / RoofPlanArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 1/4" = 1'-0"1Third Floor Plan 1/4" = 1'-0"2Roof PlanBuilding Area:Unit C:2nd Level 627 sq.ft.Terrace 466 sq.ft.Unit D:2nd Level 627 sq.ft.Terrace 466 sq.ft.0812164GRAPHIC SCALEBuilding Key:revision date notes
First Floor F.F.E58' - 2 1/2"Second Floor F.F.E69' - 4 1/2"Existing Grade57' - 6 1/2"Third Floor F.F.E80' - 6 1/2"3rd Floor T.P90' - 7 1/2"Top of Parapet92' - 3"3'-6"3'-6"1st Floor T.P68' - 1 1/2"1'-3"9'-11"2nd Floor T.P79' - 3 1/2"9'-11"1'-3"10'-1"1'-7 3/4"34'-8 3/4"Smooth Stucco clad wall; Painted white; Typ.Lap Siding by HardiePlank;Boothbay Blue1/4" metal fin4" Boral trim; Painted white:Typ.Metal flashing; AluminumAluminum accordion door42" Aluminum guard railing; PaintedAluminum frame window; Black; Typ.High grade lumber; Walnut stained at all door and windows U.O.N8'-0" TYP.at all door and windows U.O.N8'-0" TYP.Boral panel; Sand smooth; Paint TBDConcrete block low wall; NaturalFirst Floor F.F.E58' - 2 1/2"Second Floor F.F.E69' - 4 1/2"Existing Grade57' - 6 1/2"Third Floor F.F.E80' - 6 1/2"3rd Floor T.P90' - 7 1/2"Top of Parapet92' - 3"1st Floor T.P68' - 1 1/2"2nd Floor T.P79' - 3 1/2"3'-0"5'-0"3'-6"2'-6"2'-6"3'-6"3'-6"Natural stone Clad; GreyDecorative architectural screen; Metal framePre-fabricated steel stair case; Powder coated flat black9'-11"1'-3"9'-11"1'-3"10'-1"34'-8 3/4"1'-7 3/4"general elevation 1. See drawing SC1 for window and door schedules.2. See details xx/xx for typical exterior window head, sill, and jamb details and xx/xx for typical window installation details.3. At front covered patios, provide MIN 2% positive drainage away from all portions of the structure.4. See plot plan for information pertaining to wood gates and fences.5. Fiber cement panel sizes and layouts to be coordinated with Architect prior to ordering.drawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A6Building ElevationsArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 1/4" = 1'-0"1East Elevation (Front) 1/4" = 1'-0"2North Elevation (Side)0812164GRAPHIC SCALErevision date notes
First Floor F.F.E58' - 2 1/2"Second Floor F.F.E69' - 4 1/2"Existing Grade57' - 6 1/2"Third Floor F.F.E80' - 6 1/2"3rd Floor T.P90' - 7 1/2"Top of Parapet92' - 3"1st Floor T.P68' - 1 1/2"2nd Floor T.P79' - 3 1/2"3'-6"5'-0"Smooth boral panel; Painted 1'-7 3/4"10'-1"1'-3"9'-11"1'-3"9'-11"34'-8 3/4"First Floor F.F.E58' - 2 1/2"Second Floor F.F.E69' - 4 1/2"Existing Grade57' - 6 1/2"Third Floor F.F.E80' - 6 1/2"3rd Floor T.P90' - 7 1/2"Top of Parapet92' - 3"1st Floor T.P68' - 1 1/2"2nd Floor T.P79' - 3 1/2"1/4" Metal fin1'-7 3/4"10'-1"1'-3"9'-11"1'-3"9'-11"34'-8 3/4"general elevation 1. See drawing SC1 for window and door schedules.2. See details xx/xx for typical exterior window head, sill, and jamb details and xx/xx for typical window installation details.3. At front covered patios, provide MIN 2% positive drainage away from all portions of the structure.4. See plot plan for information pertaining to wood gates and fences.5. Fiber cement panel sizes and layouts to be coordinated with Architect prior to ordering.drawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A7Building ElevationsArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 1/4" = 1'-0"2South Elevation (Side) 1/4" = 1'-0"1West Elevation (Rear)1/4" Metal finCarport gate;horizontal siding on steel framerevision date notes
First Floor F.F.E58' - 2 1/2"Second Floor F.F.E69' - 4 1/2"Existing Grade57' - 6 1/2"Third Floor F.F.E80' - 6 1/2"3rd Floor T.P90' - 7 1/2"Top of Parapet92' - 3"1st Floor T.P68' - 1 1/2"2nd Floor T.P79' - 3 1/2"KitchenLivingRoomBedroom1Bedroom2Bedroom 1Bedroom 2HallwayHallway6'-8"Bedroom 2Bedroom 2KitchenDining1'-7 3/4"10'-1"1'-3"9'-11"1'-3"9'-11"34'-8 3/4"3'-6"3'-6"3'-6"LivingKitchenDiningUnit AStorageTerraceTerraceKitchenDiningLiving6'-8"6'-8"6'-8"First Floor F.F.E58' - 2 1/2"Second Floor F.F.E69' - 4 1/2"Existing Grade57' - 6 1/2"Third Floor F.F.E80' - 6 1/2"1st Floor T.P68' - 1 1/2"2nd Floor T.P79' - 3 1/2"Bedroom 1Bedroom 2KitchenLivingRoomTerraceFirst Floor F.F.E58' - 2 1/2"Second Floor F.F.E69' - 4 1/2"Existing Grade57' - 6 1/2"Third Floor F.F.E80' - 6 1/2"3rd Floor T.P90' - 7 1/2"Top of Parapet92' - 3"1st Floor T.P68' - 1 1/2"2nd Floor T.P79' - 3 1/2"Bedroom2ParkingDiningdrawing date:drawn by:ohms Collaborative536 Sears Avenue, San Diego, CA 92114 P: 619.517.8881Designer:sheet title:drawing number:project:revisions:CDP 2016-0006A8Building SectionsArellano 4 Unit ApartmentsDecember 28, 2016HA2637 Jefferson St., Carlsbad, CA 92008 1/4" = 1'-0"1Building Section 1/4" = 1'-0"2Building Section 1/4" = 1'-0"3Building Sectionrevision date notes