Loading...
HomeMy WebLinkAbout2020-04-15; Planning Commission; ; CDP 2019-0032 (DEV2019-0133) – LOVE RESIDENCESingle Family Coastal Development Permit Item No. Application complete date: March 5, 2020 P.C. AGENDA OF: April 15, 2020 Project Planner: Esteban Danna Project Engineer: Kyrenne Chua SUBJECT: CDP 2019-0032 (DEV2019-0133) – LOVE RESIDENCE - Request for approval of a Coastal Development Permit to allow for the construction of a new 2,535-square-foot single- family residence with an attached two-car garage within the Mello II Segment of the city’s Local Coastal Program located at 4615 Telescope Avenue within Local Facilities Management Zone 1. The project site is not within the appealable area of the California Coastal Commission. The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15303(a) – construction of a single-family residence – of the State CEQA Guidelines. I.RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7367 APPROVING Coastal Development Permit CDP 2019-0032 based upon the findings and subject to the conditions contained therein. II.PROJECT DESCRIPTION AND BACKGROUND Project Site/Setting: The 0.18-acre (7,865 square feet) project site is located at 4615 Telescope Avenue as shown on the attached location map. The site topography ranges from approximately 289 feet above mean sea level (AMSL) along the front property line adjacent to Telescope Avenue to an approximate range of 302-311 feet AMSL along the rear property line. The lot was graded at the time when the rest of the neighborhood was developed. The structure is proposed to be built on the relatively flat building pad at the center of the lot. Table “A” below includes the General Plan designations, zoning and current land uses of the project site and surrounding properties. TABLE A Location General Plan Designation Zoning Current Land Use Site R-4 (Residential)R-A-10000 Vacant North R-4 (Residential)R-A-10000 Single-Family Residence South R-4 (Residential)R-A-10000 Single-Family Residence East R-4 (Residential)R-A-10000 Single-Family Residence West R-4 (Residential)R-1-15000 Single-Family Residence 2 CDP 2019-0032 (DEV2019-0133) – LOVE RESIDENCE April 15, 2020 Page 2 Proposed Residential Construction: The project consists of the construction of a new 2,535-square-foot single-family residence with an attached 554-square-foot two-car garage. The proposed home will be a single story above a two-car garage. The home is designed to work with existing slope conditions, which slope up toward the rear of the property. At its highest point, the height of the home is 28’ – 3.5”, which is below the maximum allowed height of 30 feet. The contemporary architectural style is compatible with the existing homes throughout the neighborhood. The exterior is proposed to be finished in hardy plank siding, with cable rails on the front stairs, and energy-efficient asphalt composition roof shingles. Proposed Grading: Estimated grading quantities include 313 cubic yards (cy) of cut and 7 cy of fill with 306 cy of export. A grading permit will be required for this project. III. ANALYSIS The project is subject to the following regulations and requirements: A. R-4 Residential General Plan Designation; B. R-A Residential Agriculture Zone (CMC Chapter 21.08); C. Coastal Development Regulations for the Mello II Segment of the LCP and Coastal Resource Protection Overlay Zone (CMC Chapter 21.203); D. Inclusionary Housing Ordinance (CMC Chapter 21.85); and E. Growth Management (CMC Chapter 21.90). The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable city regulations and policies. The project’s compliance with each of the above regulations is discussed in detail in the sections below. A. General Plan Land Use Designation The General Plan Land Use designation for the property is R-4 Residential, which allows for residential development at a density range of 0 to 4 dwelling units per acre (du/ac) with a Growth Management Control Point (GMCP) of 3.2 du/ac. The project site has a net developable acreage of 0.18 acres; at the 3.2 GMCP, 0.58 dwelling units are allowed. Although the project’s proposed density of 5.76 du/ac exceeds the R-4 density range of 0 to 4 du/ac, one single-family dwelling unit is permitted to be constructed on a legal lot that existed as of October 28, 2004 per policy 2-P.7 of the General Plan. The subject lot was legally created prior to October 28, 2004 (Map No. 10925 recorded on May 1, 1984); therefore, the development of the subject lot with one single-family home is consistent with the R-4 General Plan Land Use designation. B. R-A Residential Agricultural Zone (R-A-10000) The project is required to comply with all applicable regulations and development standards of the Carlsbad Municipal Code (CMC) including the R-A Residential Agricultural Zone (R-A-10000). The proposed project meets or exceeds all applicable requirements of the R-A-10000 zone (Shown in Table B below). CDP 2019-0032 (DEV2019-0133) – LOVE RESIDENCE April 15, 2020 Page 3 TABLE B – R-A-10000 ZONE DEVELOPMENT STANDARDS STANDARD REQUIRED/ALLOWED PROPOSED COMPLY Front Yard Setback 20 feet 20 feet Yes Side Yard Setback 6 feet 7 feet Yes Rear Yard Setback 12 feet 18’ – 8” Yes Max Building Height 30 feet 28’ – 3.5” Yes Lot Coverage 40 percent 39 percent Yes Parking Two-car garage (20’x20’) Two-car garage (20’x20’) Yes C. Conformance with the Coastal Development Regulations for the Mello II Segment of the Local Coastal Program (CMC Chapter 21.201) and Coastal Protection Resource Overlay Zone (CMC Chapter 21.203) 1. Mello II Segment of the Certified Local Coastal Program and all applicable policies. The project site is located within the Mello II Segment of the Local Coastal Program and is not located in the appeal jurisdiction. The subject site has an LCP Land Use Plan designation of R-4 Residential, which allows for a density of 0-4 du/ac and 3.2 du/ac at the Growth Management Control Point (GMCP). The project density is consistent with the R-4 General Plan Land Use designation as discussed in Section A above. Therefore, the project is consistent with the Mello II Segment of the LCP. The project consists of the construction of a new 2,535-square-foot single-family residence with an attached two-car garage in an area designated for residential development. The proposed single-story- above-garage single-family residence is compatible with the surrounding development of one- and two- story single-family structures. The proposed residence will not obstruct views of the coastline as seen from public lands or the public right-of-way, nor otherwise damage the visual beauty of the coastal zone. No agricultural uses currently exist on the previously graded site, nor are there any sensitive resources located on the developable portion of the site. The proposed single-family residence is not located in an area of known geologic instability or flood hazard. Since the site does not have frontage along the coastline, no public opportunities for coastal shoreline access are available from the subject site. Furthermore, the residentially designated site is not suited for water-oriented recreation activities. 2. Coastal Resource Protection Overlay Zone The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone (CMC Chapter 21.203 of the Zoning Ordinance) in that the project will adhere to the city’s Master Drainage Plan, Grading Ordinance, Storm Water Ordinance, BMP Design Manual and Jurisdictional Runoff Management Program (JRMP) to avoid increased urban run-off, pollutants and soil erosion. No development is proposed in areas of steep slopes (equal to or greater than 25% gradient) and none of the native vegetation located on the subject property will be disturbed. In addition, the site is not located in an area prone to landslides, or susceptible to accelerated erosion, floods or liquefaction. D. Inclusionary Housing Ordinance (CMC Chapter 21.85) For any residential development of less than seven (7) units, the inclusionary housing requirement may be satisfied through the payment of an inclusionary housing in-lieu fee. The proposal to construct one single-family residential dwelling unit has been conditioned to pay the applicable affordable housing in- lieu fee for one unit prior to the issuance of a building permit. CDP 2019-0032 (DEV2019-0133) – LOVE RESIDENCE April 15, 2020 Page 4 E. Growth Management The proposed project is located within Local Facilities Management Zone 1 in the Northwest Quadrant of the city. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in Table C below. TABLE C – GROWTH MANAGEMENT COMPLIANCE Standard Impacts Compliance City Administration N/A Yes Library N/A Yes Waste Water Treatment 1 EDU Yes Parks N/A Yes Drainage 0.67 CFS/Basin B Yes Circulation 10 ADT Yes Fire Station No. 1 Yes Open Space N/A N/A Schools Carlsbad (E=.3536/M=.1036/HS = .0959) Yes Sewer Collection System 1 EDU Yes Water 550 GPD Yes IV. ENVIRONMENTAL REVIEW This project is exempt from CEQA per the exemptions listed below: (1) Section 15303(a) of CEQA exemptions (Class 3) exempts the construction of single-family residences in urbanized areas from environmental review. A Notice of Exemption will be filed by the City Planner upon project approval. ATTACHMENTS: 1. Planning Commission Resolution No. 7367 2. Location Map 3. Disclosure Form 4. Reduced Exhibits 5. Exhibit(s) “A” – “J” dated April 15, 2020 SKYLINE RDTELESCOPE AVHI G H R I D G E A V SPYGLASSCT MAC ARTH U R A V CDP 2019-0032 Love Residence SITE MAP J SITE E L C AMINO R E A LLA COSTA AV A L G A R DCARLSBAD B L ATTACHMENT 2 ATTACHMENT 3 :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISION TABLENUMBER DATE REVISEDBY DESCRIPTION GENERAL NOTES PROJECT DATA PROJECT TEAM ABBREVIATIONS SYMBOL LEGEND APPLICABLE CODES INDEX OF DRAWING VICINITY MAPGENERAL NOTES SCOPE OF WORK 4615 Telescope Ave., Carlsbad, CA T-1 TITLE SHEET ARCHITECTURAL A-1 SITE PLAN A-2 MAIN LEVEL FLOOR PLAN A-3 GARAGE LEVEL FLOOR PLAN A-4 ROOF PLAN A-5 MAIN & GARAGE LEVEL ELECTRICAL PLANS A-6 ELEVATIONS A-7 ELEVATIONS A-8 SECTIONS A-9 SECTIONS APN: 207-385-20-00 LEGAL: LOT 6 TR 10925 DESIGNER: TRAVIS DEAL DRAFTER: ANDRES SAAVEDRA 1320 GRAND AVE. #2 SAN MARCOS, CA 92072 (760) 809-0545 1. AS A MINIMUM STANDARD, ALL CONSTRUCTION WORK SHALL COMPLY WITH ALL APPLICABLE ADOPTED ZONING ORDINANCES, BUILDING CODES, BUILDING DEPARTMENT SUPPLEMENTAL PROCEDURES AND NEWSLETTERS AND NFPA BULLETINS. 2. THE GENERAL CONTRACTOR, THE SUBCONTRACTOR, AND MATERIAL SUPPLIERS SHALL REFER TO THE DRAWINGS, SCHEDULES AND SPECIFICATIONS AS WHOLE DETERMINING THE CONSTRUCTION REQUIREMENTS FOR THE PROJECT. 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ALL AREAS ON THE PROJECT WHICH REQUIRE TOLERANCES BETWEEN ROUGH OPENINGS AND/ OR FINISH MATERIALS AND PROVIDE FOR THE PROPER TOLERANCES TO COMPLETE THE CONSTRUCTION IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACTOR DOCUMENTS. 4. ALL DRAWINGS, SCHEDULES AND SPECIFICATION IN THE BID PACKAGE ARE TO BE CONSIDERED EQUAL PARTS OR THIS CONTRACTOR PACKAGE, THE CONTRACTOR AND HIS SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE REVIEW AND COORDINATION OF ALL DRAWINGS, SCHEDULE, AND SPECIFICATIONS, INCLUDING CIVIL, ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL, ALL DISCREPANCIES, OMISSIONS OR ERRORS THAT OCCUR SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING PRIOR TO THE SUBMISSION OF BIDS SO THAT CLARIFICATION MAY BE ISSUED. 5. ANY WORK PERFORMED IN CONFLICT WITH ANY PART OF THE CONTRACT DOCUMENTS OR CODE REQUIREMENT SHALL BE CORRECTED BY THE CONTRACTOR AT HIS OWN EXPENSE AND AT NO EXPENSE TO THE OWNER OR ARCHITECT. 6. PRIOR TO THE START OF CONSTRUCTION, THE GENERAL CONTRACTOR SHALL VERIFY LOCATION OF TRANSFORMERS AND UNDERGROUND UTILITIES WITH APPROPRIATE UTILITY COMPANIES, IN ADDITION, THE GENERAL CONTRACTOR SHALL VERIFY THE ACTUAL STATIC WATER PRESSURE AT THE PROPERTY LINE AND REPORT THE FINDINGS IN WRITING TO THE ARCHITECT AND MECHANICAL ENGINEER PRIOR TO THE START OF CONSTRUCTION. 7. THE GENERAL CONTRACTOR AND HIS SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR THE COORDINATION OF THEIR WORK WITH THE WORK OF OTHERS, SUB-CONTRACTORS SHALL VERIFY THAT ANY WORK RELATED TO THEM, WHICH MUST BE PROVIDED BY OTHERS, HAS BEEN COMPLETED AND IS ADEQUATE PRIOR TO COMMENCING THEIR WORK. 8. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, SECTIONS AND DETAILS. DIMENSIONS ARE TO FACE OF STUD OR SLAB UNLESS OTHERWISE NOTE ON DRAWINGS. DO NOT SCALE DRAWINGS. 9. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR SAFETY ITEMS AND PROCEDURES DURING THE TERM OF CONSTRUCTION. 10. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED AND THE BUILDING SHALL NOT BE USED FOR ANY PURPOSE UNTIL TOILETS AND EXIST FACILITIES ARE PROVIDED UNDER SEPARATE PERMIT. ZONE:R-4 RES / AG YEAR BUILT:- CONSTRUCTION TYPE: RESIDENTIAL OCCUPANCY TYPE: - CONSTRUCTION SHALL CONFORM TO: GOVERNING CODES: THIS PROJECT SHALL COMPLY WITH THE FOLLOWING MODEL CODES: -2016 CBC (CALIFORNIA BUILDING CODE) -2016 CMC (CALIFORNIA MECHANICAL CODE) -2016 CPC (CALIFORNIA PLUMBING CODE) -2016 CFC (CALIFORNIA FIRE CODE) -2016 CEC (CALIFORNIA ELECTRICAL CODE) -2016 CRC (CALIFORNIA RESIDENTIAL CODE) -2016 CGBSC (CALIFORNIA GREEN BUILDING STANDARDS CODE) -2016 CBEES (CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS) -STATE OF CALIFORNIA ENERGY CONSERVATION REQUIREMENTS (T-24) THE EXISTING HOUSE IS NOT SPRINKLERED. A MINIMUM OF 65% NON-HAZARDOUS CONSTRUCTION AND DEMOLITION DEBRIS WILL BE RECYCLED OR SALVAGED FOR REUSE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4, OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE (CAL GREEN SECTION 4.408.1) THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE PETROLEUM BY PRODUCTS, SOIL PARTICULATES, CONSTRUCTION WASTE MATERIALS, OR WASTE WATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED, OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. THE FINISH GRADE AND IMPERVIOUS SURFACES SHALL DRAIN AWAY FROM THE FOUNDATION WALL AT A MINIMUM SLOPE OF 2% OR SHALL FALL 6 INCHES WITHIN THE FIRST 10 FEET WHERE POSSIBLE. A FOUNDATION FORMS CERTIFICATION THAT IS CERTIFIED BY A LICENSED LAND SURVEYOR MAY BE REQUIRED BY THE BUILDING INSPECTOR AT THE FIRST FOOTING INSPECTION. A.B. ANCHOR BOLT A.C. AIR CONDITIONING ACOUST. ACOUSTICAL A.D. ACCESS DOOR/ AREA DRAIN ADD. ADDENDUM OR ADDITION ADJ. ADJUSTABLE A.E.F.F. ABOVE EXISTING FINISH FLOOR ALUM. ALUMINUM ALT. ALTERNATE &AND ∠ANGLE ANOD. ANODIZE ARCH. ARCHITECT(URAL) ASPH. ASPHALT @ AT BD. BOARD BTWN. BETWEEN B.F. BOTTOM OF FOOTING BLDG. BUILDING BLKG. BLOCKING BM BEAM B.N. BOUNDARY NAIL B.O. BOTTOM OF BOT. BOTTOM BRG. BEARING BSMT. BASEMENT B.U. BUILT-UP C. CHANNEL CER. CERAMIC C.B. CATCH BASIN C.I.P. CAST-IN-PLACE C.J. CONTROL JOINT CL CENTERLINE CLG. CEILING CLR. CLEAR(ANCE) CMU CONCRETE MASONRY UNIT CLST. CLOSET C.O. CLEAN OUT COL COLUMN CONC. CONCRETE CONSTR. CONSTRUCTION CONT. CONTINUOUS COORD. COORDINATE CORR. CORRIDOR CSK COUNTERSINK CTR. CENTER D.A. DAMP PROOFING D.F. DRINKING FOUNTAIN DBL DOUBLE DIA./Ø DIAMETER DIAG. DIAGONAL DIAPH. DIAPHRAGM DIM. DIMENSION D.L. DEAD LOAD DN. DOWN DS. DOWNSPOUT DTL. DETAIL DWG. DRAWING DWLS. DOWELS DWR. DRAWER EA. EACH E.B. EXPANSION BOLT E.J. EXPANSION JOINT EL. ELEVATOR ELEC. ELECTRIC(AL) ELEV. ELEVATION E.N. EDGE NAIL ENC. ENCLOSURE EQ. EQUAL EQUIP. EQUIPMENT E.W. EACH WAY E.W.C. ELECTRIC WATER COOLER EXT. EXTERIOR EXIST. EXISTING F.B. FLAT BAR F.D. FLOOR DRAIN FDN. FOUNDATION F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.F. FINISH FLOOR/ FACTORY FINISHF.F.E. FINISHED FLOOR ELEVATION F.P.E. FINISHED PAVING ELEVATION F.G. FINISHED GRADE F.H.C. FIRE HOSE CABINET FIN. FINISH FLR. FLOOR FLUOR. FLUORESCENT F.N. FIELD NAILING F.O.B. FACE OF BRICK F.O.C. FACE OF CONCRETE F.O.M. FACE OF MASONRY F.O.P. FACE OF PANEL F.O.S. FACE OF STUD FT. FOOT/FEET FTG. FOOTING F.S. FLOOR SINK GA. GAUGE GALV. GALVANIZED G.I. GALVANIZED IRON GL. GLASS GLB GLU-LAM BEAM GYP. BD. GYPSUM BOARD H.C. HOLLOW CORE HDR. HEADER HDWR. HARDWARE HGR. HANGER H.M. HOLLOW METAL HORIZ. HORIZONTAL HR. HOUR HT. HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING H.W. HOT WATER I.D. INSIDE DIAMETER REF REFEREMCE REINF REINFORCING REQ(D) REQUIRED REQMTS. REQUIREMENTS RESIL. RESILIENT RET RETAIN(ING) RM ROOM R.O. ROUGH OPENING S SOUTH S.C. SOLID CORE SCHED. SCHEDULE S.F. SQUARE FEET SHT. SHEET SIM SIMILAR S.M.F.E. SURFACE MOUNTED FIRE EXTINGUISHER SPEC. SPECIFICATION SQ. SQUARE S.S. STAINLESS STEEL STAGG. STAGGERED STD. STANDARD STIFF. STIFFENED STR. STRUCTURAL STL. STEEL SYM. SYMMETRICAL T. TREAD T.C. TOP OF CURB/ TOP OF CONCRETE T&G TONGUE AND GROOVE THR THRESHOLD T.I. TENANT IMPROVEMENT T.J. TOOLED JOINT T.N. TOE NAILED T.O.C. TOP OF CURB T.O.S. TOP OF SLAB T.O.W. TOP OF WALL TRANS. TRANSVERSE TYP. TYPICAL U.B.C. UNIFORM BUILDING CODE U.N.O. UNLESS NOTED OTHERWISE V.C.T. VINYL COMPOSITION TILE VENT VENTILATOR/ VENTILATION VERT VERTICAL V.R. VAPOR RETARDER VTR VENT THRU ROOF VWC VINYL WALL COVERING W WEST WDW WINDOW W/ WITH W.GL. WIRE GLASS W.H. WATER HEATER W/O WITHOUT WP WATERPROOF W.P.J. WEAKENED PLANE JOINT W.R. WATER RESISTANT IN. INCH INCL INCLUDED INSUL INSULATION INT. INTERIOR JAN. JANITOR JST. JOIST JT. JOINT KIT. KITCHEN KJ. KEYED JOINT LAM. LAMINATED LAV. LAVATORY MAS. MASONRY M.O. MASONRY OPENING MATL. MATERIAL MAX. MAXIMUM MECH. MECHANICAL MEMB. MEMBRANE MET. METAL MFR. MANUFACTURER MIN. MINIMUM MISC. MISCELLANEOUS N NORTH N.A. NOT APPLICABLE N.I.C. NOT IN CONTRACT N.T.S NOT TO SCALE NO. NUMBER O.C. ON CENTER O.D. OUTSIDE DIAMETER O.F. OVERFLOW/ OUTSIDE FACE O.F.C.I. OWNER FURNISHED/ CONTRACTOR INSTALLED O.F.O.I. OWNER FURNISHED/ OWNER INSTALLED O.H. OPPOSITE HAND/ OVERHEAD OPN'G OPENING OPP OPPOSITE ⅊PROPERTY LINE PERIM. PERIMETER PERPL. PERPENDICULAR PLAM. PLASTIC LAMINATE PLAS. PLASTER PLAST. PLATIC P.D. PLANTER DRAIN PLYWD PLYWOOD R. RISE R.C.P REFLECTED CEILING PLAN R.D. ROOD DRAIN SEP 2019 SQUARE FOOTAGE BREAKDOWN LOT SIZE:7,865 S.F. AREA OF HOUSE:2,535 S.F. AREA OF PORCH:554 S.F. STAIRS:51 S.F. ROOF DECK:213 S.F. GARAGE:554 S.F. - N E W R E S I D E N C E C O N S T R U C T I O N C O N S I S T I N G O F 2 , 5 3 5 S.F. w/ A ROOF DECK OF 213 S.F., 554 S.F. PORCH AND 554 S.F. GARAGE UNDER RESIDENCE X XX AX.X 13 4 2 AX.X X 1 C 1 A A 1 14 2 100 11 DETAIL: DETAIL NUMBER SHEET WHERE DRAWN SHEET WHERE DRAWN ELEVATION NUMBER INTERIOR ELEVATION: SECTION NUMBER SHEET WHERE DRAWN BUILDING SECTION: CENTER LINE FACE DIMENSION CENTER LINE DIMENSION ELEVATION FINISH ELEVATION FINISH MATERIAL GRID OR COLUMN LINE TRUE NORTH WINDOW TYPE NORTH WALL TYPE KEYNOTE REVISION ROOM NUMBER DOOR NUMBER ALIGN - TYPICAL ATTACHMENT 4 PL PL PL PL PL PL PL PLPL CL CL CL CLCL CL CL Δ PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISIONTABLENUMBERDATEREVISEDBYDESCRIPTION SITE PLAN SCALE: 1/8"=1'-0"N BMP'S LEGEND PDS 659 PDS 659 BROW DITCH BERM DIRECTION OF LOT DRAINAGE MATERIALS & WASTE MANAGEMENT BMP's WM-1 WM-4 WM-8 WM-5 WM-9 WM-6 MATERIAL DELIVERY & STORAGE SPILL PREVENTION AND CONTROL CONCRETE WASTE MANAGEMENT SOLID WASTE MANAGEMENT SANITARY WASTE MANAGEMENT HAZARDOUS WASTE MANAGEMENT TEMPORARY RUNOFF CONTROL BMP's SS-2 PRESERVATION OF EXISTING VEGETATION SS-3 SS-4 SS-6 SS-7 SS-10 SC-1 SC-2 SC-5 SC-6 SC-7 BONDED OR STABILIZED FIBER MATRIX (WINTER) HYDROSEEDING (SUMMER) SS-8 STRAW OR WOOD MULCH/ PHYSICAL STABILIZATION (WINTER) ENERGY DISSIPATOR SILT FENCE SEDIMENT/ DESILTING BASIN FIBER ROLLS SC-8 GRAVEL OR SAND BAGS/ STREET SWEEPING AND VACUUMING SC-10 STORM DRAIN INLET PROTECTION NS-2 DEWATERING FILTRATION TC-1 STABILIZED CONSTRUCTION ENTRANCE TC-2 CONSTRUCTION ROAD STABILIZATION TC-3 ENTRANCE / EXIT TIRE WASH POST-CONSTRUCTION SITE DESIGN BMP's 4,3,1 MAINTAIN NATURAL DRAINAGE PATHWAYS & HYDROLOGIC FEATURES 4,3,2 CONSERVE NATURAL AREAS, SOILS & VEGETATION 4,3,3 MINIMIZE IMPERVIOUS AREA 4,3,4 MINIMIZE SOIL COMPACTION 4,3,5 IMPERVIOUS AREA DISPERSION 4,3,6 RUNOFF COLLECTION 4,3,7 LANDSCAPING WITH NATIVE OR DROUGHT TOLERANT SPECIES 4,3,8 HARVESTING AND USING PRECIPITATION POST CONSTRUCTION SOURCE CONTROL BMP's 4,2,1 PREVENTION OF ILLICIT DISCHARGES INTO THE MS4 4,2,2 STORM DRAIN STENCILING & POSTING OF SIGNAGE 4,2,3 PROTECTED OUTDOOR MATERIALS STORAGE AREAS 4,2,4 PROTECT MATERIALS STORED IN OUTDOOR WORK AREAS 4,2,5 PROTECT TRASH STORAGE AREAS 4,2,6 ADDNL. BMP's BASED ON POTENTIAL RUNOFF POLLUTANTS A ON SITE STORAGE DRAIN INLETS B INTERIOR FLOOR DRAINS & ELEVATOR SHAFT SUMPS C INTERIOR PARKING GARAGES D NEED FOT FUTURE INDOOR & STR. PEST CONTROL E LANDSCAOE/ OUTDOOR PESTICIDE USE F POOLS, SPAS, PONDS, FOUNTAINS & WATER FEATURES G FOOD SERVICE H TRASH OR REFUSE AREAS I INDUSTRIAL PROCESSES J OUTDOR STORAGE OF EQUIP. OR MATERIALS K VEHICLE AND EQUIPMENT CLEANING L VEHICLE/ EQUIPMENT REPAIR AND MAINTENANCE M FUEL DISPENSING AREAS N LOADING DOCKS O FIRE SPRINKLER TEST WATER P MISCELLANEOUS DRAIN OR WASH WATER Q PLAZAS, SIDEWALKS, DRIVEWAYS & PARKING LOTS B PEV PEV M M TSP TSP S/W S/W EBM EBM FR FR DW DW SITE PLAN LEGEND NORTH ARROW CL PL PROPERTY LINE STREET CENTER LINE 0'-0"DIMENSION LINE GENERAL NOTES LANDSCAPE CONSTRUCTION DRAWINGS ARE REQUIRED IF THE PROJECT INCLUDES 500 SQUARE FEET OR GREATER OF NEW LANDSCAPING. THE LANDSCAPE REQUIREMENTS ARE DETAILED IN THE CITY'S LANDSCAPE MANUAL AVAILABLE ONLINE AT: http://www.carlsbadca.gov/civicax/filebank/blobdload. aspx?BlobID=24086 *450 SQUARE FOOT OF LANDSCAPE PROPOSED. 500 MAXIMUM SEP 2019 LOT COVERAGE LOT SIZE:7,865 S.F. MAX. LOT COVERAGE:.40 (3,146) S.F. AREA OF HOUSE LOT CVRG.:2,535 S.F. AREA OF PORCH:554 S.F. STAIRS:51 S.F. TOTAL LOT COVERAGE:3,130 (39%)S.F. ROOF DECK:213 S.F. GARAGE:554 S.F. VICINITY MAP PROJECT DATA NAME AND ADDRESS OF OWNER (760) 2103-0526 LOVE RESIDENCE APN: 207-385-20 4615 TELESCOPE AVE. CARLSBAD, CA 92008 :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISIONTABLENUMBERDATEREVISEDBYDESCRIPTIONMAIN LEVEL FLOOR PLAN SCALE: 1/4"=1'-0" SEP 2019 GUARDRAIL DETAIL1 :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISIONTABLENUMBERDATEREVISEDBYDESCRIPTIONGARAGE LEVEL FLOOR PLAN SCALE: 1/4"=1'-0" SEP 2019 :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISIONTABLENUMBERDATEREVISEDBYDESCRIPTIONROOF PLAN SCALE: 1/4"=1'-0" SEP 2019 $ $ $ $ $ $$$$$$$$$$$$$$ $ $ $ $ :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISIONTABLENUMBERDATEREVISEDBYDESCRIPTIONGARAGE LVL ELECTRICAL PLAN SCALE: 1/4"=1'-0" MAIN LEVEL ELECTRICAL PLAN SCALE: 1/4"=1'-0" ELECTRICAL NOTES ELECTRICAL LEGEND $1. ALL LUMINARIES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH CBEES TABLE 150.0-A. 2. ALL LED LUMINARIES AND LAMPS SHALL BE MARKED "JA8-2016" AND LISTED IN THE CALIFORNIA ENERGY COMMISSION DATABASE AT HTTPS://CACERTAPPLIANCES.ENERGY.CA.GOV/PAGES/APPLIANCESEARCH.ASPX 3. ALL RECESSED DOWNLIGHT AND ENCLOSED LUMINARIES SHALL BE MARKED "JA8-2016" AND LISTED IN THE CALIFORNIA ENERGY COMMISSION DATABASE HTTPS://CACERTAPPLIANCES.ENERGY.CA.GOV/PAGES/APPLIANCESEARCH.ASPX 4. RECESSED DOWNLIGHT LUMINARIES IN CEILINGS SHALL NOT BE SCREW-BASED. 5. BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS: AT LEAST ONE LUMINARIE IN EACH SPACE SHALL BE CONTROLLED BY A VACANCY SENSOR. 6. ALL LUMINARIES REQUIRING "JA8-2016" OR "JA8-2016-E" MARKING SHALL BE CONTROLLED BY A DIMMER OR VACANCY SENSOR. 7. OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING SHALL BE CONTROLLED BY ONE OF THE FOLLOWING: -PHOTOCONTROL AND MOTION SENSOR -PHOTOCONTROL AND AUTOMATIC TIME-SWITCH CONTROL -ASTRONOMICAL TIME CLOCK -ENERGY MANAGEMENT CONTROL SYSTEM PER CBEES 150.0(K)3AiiiC 8. ELECTRICAL BOXES SHALL HAVE DRYWALL, PLASTER OR PLASTERBOARD SURFACES FINISHED SO THERE WILL BE NO GAPS OR OPEN SPACES GREATER THAN 1/8" AT THE EDGE OF THE BOX PER ARTICLE 314.21 (CEC). IN WALLS OR CEILINGS BOXES SHALL BE INSTALLED SO THAT THE FRONT EDGE OF THE BOX OR PLASTER RING SHALL NOT BE RECESSED MORE THAN 1/4" FROM NON-COMBUSTIBLE FINISH SURFACE AND SHALL BE FLUSHED WITH A COMBUSTIBLE SURFACE PER ARTICLE 314.20 (CEC). 9. NEW BOXES USED AT LUMINAIRE OR LAMPHOLDER OUTLETS IN A CEILING SHALL BE REQUIRED TO SUPPORT LUMINAIRE WEIGHING A MINIMUM OF 50 LBS. BOXES USED AT LUMINAIRE OUTLETS IN WALLS SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF THE LUMINAIRE PERMITTED, IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR THIS PURPOSE. (314.27 CEC) SEP 2019 :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISIONTABLENUMBERDATEREVISEDBYDESCRIPTIONREAR ELEVATION SCALE: 1/4"=1'-0" FRONT ELEVATION SCALE: 1/4"=1'-0" SEP 2019 :ETAD:YBDEDIVORPSGNIWARD:ELACS :TEEHSREVISIONTABLENUMBERDATEREVISEDBYDESCRIPTIONSOUTH ELEVATION SCALE: 1/4"=1'-0" NORTH ELEVATION SCALE: 1/4"=1'-0" SEP 2019