2659 GATEWAY RD; 107; CBC2020-0062; Permit
Building Permit Finaled cfc ity of Carlsbad Commercial Permit.' CARLSBAD, CA 92009-1761 Work Class: Tenant Improvement Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check M. Plan Check #: Print Date: 08/06/2020 Job Address: 2659 GATEWAY RD, # 107, Permit Type: BLDG-Commercial Parcel #: 2131912500 Valuation: $43,858.93 Occupancy Group: B #of Dwelling Units: Bedrooms: Bathrooms: Permit No: CBC2020-0062 Status: Closed - Finaled Applied: 02/13/2020 Issued: 05/21/2020 Finaled Close Out: Inspector: CRenf Final Inspection: 08/06/2020 Project Title: - Description: MENCHIES: 943 SF TENANT IMPROVEMENT YOGURT SHOP TO YOGURT SHOP Property Owner: REGENCY BRESSI LLC 100 WILSHIRE BLVD, # 700 SANTA MONICA, CA 90401 FEE AMOUNT BUILDING PERMIT FEE ($2000+) - $367.60 BUILDING PLAN CHECK FEE (BLDG) $257.32 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $43.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $45.00 5B1473 GREEN BUILDING STATE STANDARDS FEE $2.00 STRONG MOTION-COMMERCIAL $12.28 Total Fees:' $727.20 Total Payments To Date: $727.20 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov (City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Checic Est. Value PC Deposit Date Job Address way Road, Carlsbad, CA 92009 D107 APN: Tenant Name:Menchie's Frozen Yogurt CT/Project It: Lot #:________ Occupancy: B Construction Type: EyJsitinQ Fire Sprinklers: EY no Air Conditioning: O no BRIEF DESCRIPTION OF WORK: Addition/NeW: New SF and Use, __New SF and Use, Deck SF, _________Patio Cover SF (not Including flatwork) Self Served Self Served J Tenant improvement:943 SF, Existing Use Yogurt Proposed Use Yogurt SF, Existing Use Proposed Use O Pool/Spa: SF Additional Gas or Electrical Features? Solar: _______ KW, _____ Modules, _______ Mounted, Tilt: Yes/ No, RMA: Yes / No, Panel Upgrade: Yes I No Plumbing/Mechanical/Electrical Only: o Other: APPLICANT (PRIMARY) PROPERTY OWNER Name: Ashley Rosado Name: Regency Bress LLC Address: 604 Courtland Street, Suite 100 Address: 2641 Gateway Road city: Orlando State: FL Zip:32804 City. Carlsbad State: CA Zip: 92009 Phone: 407.445.5008 -... Phone: 760.930.0020 Email:arosado@1nterr1an11c.com aiI:____________________________________ CONTRACTOR BUSINESS I. Name: SoIeL (M rQd &4' tc1aS TrC. Address: '/2 4ae5f-'c. Clty:&, Ll1t€, State: R Zip: 72ø ) 8 Phone: Email: (6i14 State License :R 2c4 I R7 Bus. 1.Icense:'6i4S2gI7.63 z.s DESIGN PROFESSIONAL Name: interpiaflLLC Address: 604 Courtiand Street, Suite 100 City: Orlando State: FL Zip: 32804 Phone: 407.645.5008 Email: dcadaclo@interplanllc.com Architect State License: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its Issuance, also requires the applicant for such permit to file a signed statement that he/she Is licensed pursuant to the provisions of the Contractor's Ucense Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis for the alleged ,exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Bulldingccarlsbadca.gov B-2 Page 1 of 2 Rev. 06/18 (OPTION A): WORICERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: CII have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit Is Issued. 0 have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. My workers' compensation Insurance carrier and policy number are: Insurance Company Name: Z No. Expiration Date: ificate of Exemption: i certify that In the performance of the work for which this permit Is Issued, I shall not employ any person In any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to Z cl,, additia the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. CONTRACTOR SIGNATURE: ___°AGENT DATE: '5-20 -22ô (OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that lam exempt from Contractor's License Law for the following reason: CI I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property Improvement. Dyes CI No 2.1 (have! have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name /address/ phone/ contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (Include name/ address/ phone/type of work): OWNER SIGNATURE: DAGENT DATE:____________ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there Is a construction lending agency for the performance of the work this permit is Issued (Sec. 3097 (I) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration foim or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Dyes CI No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? CI Yes CI No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above Information is correct and that the Information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREETO SAVE, INDEMNIFYAND KEEP HARMLESS THE CITY OF CARLSBAD AGAINSTALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY INANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMFTOSHA An OSHA permit Is required for excavations over 5'O' deep and demolition or construction of structures over stories In height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit Is not commenced within 180 days from the date of such permit or If the building or work authorized by such permit Is suspended or abandoned at any time after the work Is commenced fora period of 180 days (Section 106.44 Uniform Building Code). APPLICANT SIGNATURE: 44. ,&4a64 Agent DATE: 2.12.20 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: BuIIdlngccarlsbadca.pov B-2 Page 2 of 2 Rev. 06/18 Permit Type: BLDG-Commercial Application Date: 02/13/2020 Owner: REGENCY BRESSI LLC Work Class: Tenant Improvement Issue Date: 05/21/2020 Subdivision: Status: Closed - Finaled Expiration Date: 01/26/2021 Address: 2659 GATEWAY RD. # 107 IVR Number: 24828 CARLSBAD, CA 92009-1761 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 08/0612020 0810612020 BLDG-Final Inspection 134896-2020. Passed Chris Renfro , Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes, BLDG-Plumbing Final Yes BLDG-Mechanical Final 'Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Thursday, August 6, 2020 - - Page 2 of 2 Building Permit Inspection History Finaled (7 ity of Carlsbad Permit Type: BLDG-Commercial Application Date: 02/13/2020 Owner: REGENCY BRESSI LLC Work Class: Tenant Improvement Issue Date: 05/21/2020 Subdivision: Status: Closed - Finaled Expiration Date: 01/26/2021 Address: 2659 GATEWAY RD, # 107 CARLSBAD, CA 92009-1761 IVR. Number: 24828 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 0610412020 0610412020 BLDG-81 Underground 129344-2020 Passed Chris Renfro Complete Combo(111221,3I) Checklist Item COMMENTS - Passed BLDG-Building Deficiency Yes BLDG-il Foundation-Ftg-Piers No (Rebar) BLDG-12 Steel-Bond Beam No BLDG-21 Yes Underground-Underfloor Plumbing BLDG-31 Yes Underground-Conduit Wring BLDG-84 Rough I29345-2020 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 0611612020 0611612020 BLDG-17 Interior I30255-2020 Passed Chris Renfro Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0712712020 0712712020 BLDG-I4 133880-2020 Partial Pass Chris Renfro Reinspection Incomplete Frame/Steel/Bolting/We IdIng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Rough framing for rooftop unit curb. OK to Yes roof 0712812020 07/2812020 BLDG-23 I33908-2020 Passed Chris Renfro Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/30/2020 BLDG-85 T-Bar, Ceiling 134208-2020 Passed Chris Renfro Complete Grids, Overhead Thursday, August 6, 2020 Page I of 2 BACKFLOW PREVENTION ASSEMBLY TEST REPORT Palomar Backf low (760) 746-2501 Phone Assembly ID Facility Name Acct Number Meter I 111janal Test Report Due: Service Address 4 1)p-. Schedule Code (fAtlf,fAd, CA 92009 Assembly Info (Replacement/Correction) Assy Location SN fl I ncien Tap Number U I Protection WyncoMfr [1I /k,J4.f5 Contact Name Ph Type 11 RP Map Page I #2 Size El Model [] LFOOK if Install Date Add Acc# I JConfinement I J Freeze Protection Hazard Type Haz. Level Line pressure at time of test: REPORT OF TEST RESULTS j Approved BFP Check Valve #1 Check Valve #2 Relief Valve PVB/SVB Shut Off Valves Initial Test B Held at Si PSID Closed Tight Leaked Held at PSID Closed Tight Leaked Fail El Opened at .4 PSID Did Not Open Air Inlet Opened at PSID Did not Open E Check Held at PSID #1 #2 Leaked Closed Tight Leaked - El - El Pass R E P A R E CLEANED REPLACED Disc LI Spring Fj Guide Seat 0-Ring(s) Module Rubber Kit LI ____ D CLEANED REPLACED fl Disc Spring Ej Guide Seat 0-Ring(s) Module Rubber Kit LI ____11 II CLEANED REPLACED El Disc Spring Diaphragm Seat J 0-Ring(s) Module Ej Rubber Kit LI ___ D CLEANED REPLACED fl Air Inlet Disc Airl Inlet Spring Ej Check Disc Check Spring Float LI Diaphragm Rubber Kit LI ____ CLEANED REPLACED REPAIR Other LI El LILI LI LI Other/Notes:R.S.,USC 10th Edit. Final Test PSID LI Closed Tight PSID11 LI Closed Tight Lii Opened at PSID Air Inlet PSID CK Valve PSID Closed Tight LI LI Pass LI THE ABOVE REPORT IS CERTIFIED TO BE TRUE: 1A Tested By Date Certificate # Gage # Test Result Testing Company's Conatact Information P( !o f7i-It4L OOt-1 P0 Box 2702 Fail Escondido, C4 . 92033 DATE: MAY 6, 2020 JURISDICTION: Carlsbad EsGV/0 * I APPLlCANT A SAFEbui1t'Compa ny ' JURIS. PLAN CHECK #.: CBC2020-0062 SET: II PROJECT ADDRESS: 2659 Gateway Rd. PROJECT NAME: Menchies Tenant Improvement El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that th plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Ashley Rosado Telephone #: 407-645-5008 Date contacted$'1 In j_y7 Email: arosado@interplanllc.com Mail Telephone lFax In Person REMARKS: CPlase add the oUoViñ bte theplansTãtthêCity PëCPC (liii3Fñialler_arerequired to b&sloped at 2/o(1/4ëffoot):All te Ii huld I5ilãped at 2%(1/4' per foot) or i%(118" per foot) if necessary By: Connor Reuss/ Steven Miller Enclosures: EsGil 4/27/20 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 01 WIN EsGil V/ W A SAFEbuIttCompany DATE: 3/3/2020 U APPLICANT U JURIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2020-0062 SET: I PROJECT ADDRESS: 2659 Gateway Rd. PROJECT NAME: Menchies Tenant Improvement LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: LI EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Ashley Rosado Telephone #: 407-645-5008 Date contacted: '3 (by5) Email: arosado©interplanllc.com 0j Mail Telephone Fax In Person LI REMARKS: c-PM By: Jason Pasiut Enclosures: EsGil 2/18/2020 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC2020-0062 3/3/2020 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK #.: CBC2020-0062 OCCUPANCY: B TYPE OF CONSTRUCTION: ALLOWABLE FLOOR AREA: complies SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 2/13/2020 DATE INITIAL PLAN REVIEW COMPLETED: 3/3/2020 JURISDICTION: Carlsbad USE: Yogurt Shop ACTUAL AREA: 943sf STORIES: 1 HEIGHT: unchanged OCCUPANT LOAD: 16 DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/18/2020 PLAN REVIEWER: Jason Pasiut FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, theapproval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC2020-0062 3/3/2020 [DO NOT PAY - THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2020-0062 PREPARED BY: Jason Pasiut DATE: 3/3/2020 BUILDING ADDRESS: 2659 Gateway Rd. BUILDING OCCUPANCY: B BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 943 46.51 43,859 Air Conditioning Fire Sprinklers TOTAL VALUE 43,859 Jurisdiction Code 1cb ]By Ordinance 1997 UBC Building Permit Fee I 1 1997 UBC Plan Check Fee [] 1 Type of Review: P Complete Review r tructural Only r ther ilepeats r r Repetitive Fee burly I 1 Hr. © * $239=26 Fee p. V Comments: Sheet 1 of 1 Carlsbad CBC2020-0062 3/3/2020 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. BUILDING AND LIFE SAFETY REQUIREMENTS PLANS Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Type of Construction 2. On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, fire sprinklers/alarms, etc.). Additionally, provide the following note on the plans, per Sec. 107.3.4.1: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." EXITS The common path of egress travel shall not exceed the limit given in Table 1006.2.1. of 100'. Common path shall be measured from the most remote point within the space which would be the freezer. Note on the plans: "All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort." Section 1010.1.9. In lieu of the above, in a Group B, F, M or S occupancies (or places of religious assembly or Group A occupancies having an occupant load of 300 or less), you may note on the plans "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." This signage is only allowed at the main exit. Section 1010.1.9.4. Carlsbad CBC2020-0062 3/3/2020 The occupant load of the space shall be posted in a conspicuous place, near the main exit r exit access doorway from the space. Posted sins shall be of an approved legible permanent design per Section 1004.9 STRUCTURAL Provide minimum structural details and specifications on the plans to show that all structural materials and modifications will comply with the design calculations and building code requirements for the placement of new rooftop equipment. Section 107.2. Detail 12 on sheet A3.0 and the Responsibility Chart on sheet AO identify the mechanical contractor as the responsible party for providing details and calculations for the new rooftop equipment. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2016 edition of California Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. REMODELS. ADDITIONS AND REPAIRS When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: The area of specific alteration, repair or addition must comply as "new" construction. A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. The path of travel shall include the existing parking. Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. Existing drinking fountains (if any) must be shown to comply with all accessibility features. Existing public telephones (if any) must be shown to comply with all accessibility features. An accessible entrance. An accessible route to the altered area. 8. Accessible routes shall coincide with the general circulation paths. Section 11 B- 206.3. Carlsbad CBC2020-0062 3/3/2020 9. Show that a 36" wide detectable warning material is provided at boundaries between walkways and vehicular ways. Sections 11 B-247.1.2.5 and 11 B-705.1.2.5. ACCESSIBLE PARKING 10. Each separate lot or parking structure where parking is provided for the public, as clients, guests or employees, shall provide accessible parking as required by Section 11B-208.2. 11. Show on the site plan the required number of accessible parking spaces for new facilities. Per Table 11 B-208.2, the minimum number of spaces is: 1 for each 25 spaces up to 100 total spaces. 1 additional space for each 50 spaces for between 101 and 200 total spaces. 1 additional space for each 100 spaces for between 201 and 500 total spaces. For between 501 and 1000 total spaces, a minimum of 2% of the total number of spaces is required. For greater than 1000 spaces, 20 plus 1 for each additional 100 spaces. 12. Show that the accessible parking spaces are located, per Section 11 B-208.3.1 as follows: On the shortest possible route to an accessible entrance, when serving a particular building. On the shortest route of travel to an accessible entrance of a parking facility. Spaces are to be dispersed and located closest to accessible entrances where buildings have multiple accessible entrances with adjacent parking. 13. Show that accessible 'parking spaces comply with Section 11 B-502.2 as follows: Single spaces shall be 14' wide and outlined to provide a 9' parking area and a 5' loading and unloading area. This loading/unloading area may be on either side of the vehicle. When more than one space is provided, in lieu of providing a 14' space for each space, two spaces can be provided within a 23' area with a 5' loading zone between each 9,0" wide space. Each space is to be a minimum of 18' in depth. 14. At least one in every 6 accessible parking spaces (but not less than one) shall be served by an access aisle 8' in width and designated as VAN ACCESSIBLE, per Section 11 B-208.2.4 This loading/unloading area must be on the passenger side of the vehicle. Alternately, the parking stall may be 12' wide with the access aisle 5' wide. Section 11 13-502.2. Carlsbad CBC2020-0062 3/3/2020 15. The words "NO PARKING" shall be painted on the ground within each loading and unloading access aisle (in white letters no less than 12" high and located so that it is visible to traffic enforcement officials). Section 11 B-502.3.3. 16. Curb ramps and the flared sides of curb ramps shall not encroach into any accessible parking space or the adiacent access aisle. Section 11 B-406.5.1. 17. Show on the site plan that accessible parking space(s) are to be located such that a person with a disability is not required to travel behind parking spaces other than to pass behind the parking space in which they parked, per Section 11 B-502.7. 1. 18. Show that a bumper or curb is to be provided, and located at each space, to prevent encroachment of cars into the required width of walkways, per Section 11 B-502.7.2. 19. Show or note that the maximum slope of the parking surface at the accessible space and adjacent access aisle, in any direction, is :5 1:48, per Section 11 B-502.4. 20. Show or note on the plans that the accessible parking spaces are to be identified by a reflectorized sign, permanently posted immediately adjacent to and visible from each space, consisting of: A profile view of a wheelchair with occupant in white on dark blue background. The sign shall ~!70 in.2 in area. Additional language or sign below the symbol of accessibility stating, "Minimum Fine $250". When in the path of travel, they shall be posted ~80" from the bottom of the sign to parking space finished grade. Signs may also be centered on the wall of the interior end of the parking space. Van-accessible spaces shall have an additional sign "Van-Accessible" mounted below the symbol of accessibility. In addition, the surface of each accessible space is required to be marked with the international symbol of accessibility. 21. Show, or note, that an additional sign shall also be posted in a conspicuous place at each entrance to off street parking facilities, or immediately adjacent to and visible from each stall or space. Section 11 B-502.8.2. The sign shall be ~1 7" x 22" with lettering not 1"in height. The required wording is as follows. "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or special license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at or by telephoning Carlsbad CBC2020-0062 3/3/2020 Blank spaces shall be filled shall be filled in with appropriate information as a permanent part of the sign. CURB RAMPS Curb ramps shall be constructed where a pedestrian way crosses a curb, per Section 202. Plans shall show that curb ramps are ~48" wide with a slope of :51:12 (8.33%), per Section 11 B-406.5.2. Show that the landing at the top of the curb shall be level and ~48" depth for the entire width of the curb ramp. Section 11 B-406.5.3. The slope of the fanned or flared sides of curb ramps shall not exceed 1:10, per Section 11 B-406.2.2. Show that detectable warnings, 36" deep and extending the full width of the curb ramp, are to be installed for all curb ramps (regardless of slope), per Section 11 B-705. Only approved DSA/AC detectable warning products and directional surfaces shall be installed. Section 11 B-705.3. Locate curb ramps to prevent obstruction by parked cars, per Section 11 B-406.5.1. WALKS AND SIDEWALKS If any proposed walks slope >1:20 (5%) they must comply with ramp requirements, per Section 11 B-402.2. Walks along an accessible route of travel are required to be ~48" minimum in width and have slip resistant surfaces, per Section 11 B-403.5.1, Exception 3. The maximum permitted cross slope for walkways shall be 1:48, per Section 1113- 403.3. Show or note that any abrupt level changes will be :51/21' along any accessible route of travel. When changes do occur, they shall be beveled with a slope of :51 :2. Level changes of :5'/4" may be vertical. Section 11 B-303. NOTE: If level changes >1/2", they must comply with the requirements of ramps. Show that a 60" x 60" level area is provided at areas where a door (or gate) swings toward the walk in the accessible route of travel, per Section 11 B-404.2.4. Show that the walk extends ~!24" beyond the strike edge of the strike edge of any door (or gate) that swings toward the walk. Provide details or interior elevations to show that objects projecting from walls with their leading edges comply with Section 11 B-307.2: Carlsbad CBC2020-0062 3/3/2020 >27' but :580" above finished floor protrude :54" into walks, halls, corridors, passageways or aisles. :527" or >80" above finished floor may protrude any amount. Freestanding objects mounted on posts or pylons may overhang :512" into the walk, hall, etc. if ~27" but :580" above ground surface or finished floor. Show that walks with continuous gradients are provided with level areas ~60" long at intervals of 400'0" maximum, per Section 11 B-403.7. Show that a 36" wide detectable warning material is provided at boundaries between walkways and vehicular ways. Sections 11 B-247.1.2.5 and 11 B-705.1.2.5. Plans indicate that more than one route of travel is to be provided. Revise plans to show that all routes are to be made accessible, per Section 11 B-206.2.1. GENERAL ACCESSIBILITY REQUIREMENTS DRINKING FOUNTAINS Accessible drinking fountain is required. Places that serve food can provide a water station, show location and cup dispenser. P415, 415.2 and 11 B-602. SIGNAGE Per Section 1013.4, tactile exit signs shall be required at the following locations: a) Each grade-level exit door. The tactile exit sign shall have the word, "EXIT." PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: I ARCHITECTURAL P&M ITEMS Please note the fire sprinklers are a deferred item within the Title Sheet. PLUMBING (2019 CALIFORNIA PLUMBING CODE) Please the following note on the plans: "Per CPC 906.1, ABS/PVC vent terminations up through the roof exposed to sunlight are required to be protected by water based synthetic latex paints." Metering lavatories faucets can deliver a mix of 0.2 gallons per cycle. Please specify this within the fixture schedule. CPC 407.2.4 Carlsbad CBC2020-0062 3/3/2020 Show the size of the waste lines for the lavatory and water closet (i.e. 3" waste for WC is required). Please state in the plans that all domestic (i.e. potable) hot water piping will have a minimum insulation for the following pipe sizes: ½" pipe (½" insulation); 3/4" pipe (1" insulation); 1"- 1 1/2" pipes (1 ½" insulation); 2" pipes are larger (2" insulation). CPC 609.11 & ES 150.0(j) Please show the slopes for all horizontal waste pipes within the plumbing plans. Note: All waste pipes that are smaller than 4" must have a minimum slope of 2%. Please show on the plans. CPC 708.1 Please note the Health Department may require the grease interceptor to be removed to another location. MECHANICAL (2019 CALIFORNIA MECHANICAL CODE) For the walk in cooler/freezer (separate calculations), please provide calculations that show compliance with CMC 1104.2 "Refrigerant Concentration Limit" for the worst- case concentration/area scenario (i.e. please see CMC Table 1102.3 for allowable quantities). Clearly specify within the mechanical plans that a duct leakage test will be conducted that complies with CMC 603.10.1 Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. Carlsbad CBC2020-0062 3/3/2020 STRUCTURAL CALCULATIONS MENCHIE'S BRESSI RANCH TENANT IMPROVEMENTS CARLSBAD, CA Prepared For: EL RANCHO MCGINNO BRESSI RANCH, LLC MEC Project No.: 2006 Date Issued: 4/14/20 Revision Dates: Prepared By: MCNEFF ENGINEERING 0 I& CONSULTING A PROFESSIONAL CORPORATION 1991 VILLAGE PARKWAY SUITE 115 ENCINITAS, CA 92024 T (760) 479-9838 www.mcneffengineering.com 4cV3c.oa0 oGX, JOB 3RE951, P-t'-* r. SHEET NO.___________ OF 3 1-4 CALCULATED BY_____________________ DATE_I_'o CHECKED BY_______________________ DATE MNEFF ENGINEERING Im & CONSULTING A PROFESSIONAL CORPORATION 1991 Village Park Way, Suite 115 Encinitas, CA 92024 Tel: (760) 479-9838 • Fax: (760) 479-9837 i Li P4'uI L!7lV0T PjAc.q lJ 401 - - - ....................................r................ . o4 Lf w/mri jrr t - - J.J o5TS 2O 64410 14.01 fl CUCAC:LO4VALLt) ... 1.2 Frj j9 I5 -----------__ ________ -r1rJ_ .... .......... ............ ........... t....L...... (eoaO JJPLI-) tiii 9Jiw kV'Jc' 2 c' r- Y.- 'J C_ 'I- LA b II................. MCNEFF ENGINEERING I1& CONSULTING A PROFESSIONAL CORPORATION 1991 Village Park Way, Suite 115 Encinitas, CA 92024 Tel: (760) 479-9838 • Fax: (760) 479-9837 SHEET NO. CALCULATED BY________ CHECKED BY__________ OF 13 flAT DATE Lp;l;T.:L3 ISO 'i ittIzJ0 4' LI F.L... .... L A4J\ olA -If Ii,LL C i0tt1 M (1&L\ (CD ...J........ ...L ......... ........... .. ............ ........ ....... - VI IIIg' JLl U - rVi PL LJ o? çi j' ' c :112&-t,zc'.62 III MCNEFF ENGINEERING & CONSULTING A PROFESSIONAL CORPORATION 1991 Village Park Way, Suite 115 Encinitas, CA 92024 Tel: (760) 479-9838• Fax: (760) 479-9837 JOB SHEET NO.__________________________ OF 2) CALCULATED BY________________________ DATE____________________ CHECKED BY__________________________ DATE____________________ SCAlE______ L-i )JO I"Vb ok- : L ii?[? TI4 c? re - - (3 '2jtoT j/ ii T - - '' M VT If - - ........... V 1b - 1OM1l b - V fJJ kJ& IC. 'r (2 1-i;t k>I' Vl&OP TLc ______ - - -L z iI to : - - - t'1 !._.._i_.._.4 * = _______ - CoAA CT5FOV.Y - 4 uj /Jt Ll ________ ,: N) 0¼ Q - - I :- - - - - H BACKFLOW PREVENTION ASSEMBLY TEST REPORT Palomar Backt low (760) 746-2501 Phone Assembly ID Facility Name Acct Number Meter Test Report Due: Service Address w%y Sn€. rjr-. Schedule Code CA qôog Assembly Info (Replacement/Correction) Assy Location SN 1:11 lctc180l Tap Number I Protection Mfr 1:11 Contact Name Ph Type LI RP Map Page I #2 Size LII I" Model E]LQ'vV if Install Date Add Acc# I J Confinement I 0 Freeze Protection I Hazard Type Haz. Level Line pressure at time of test: 50 REPORT OF TEST RESULTS 0 Approved BFP Check Valve #1 Check Valve #2 Relief Valve PVB/SVB Shut Off Valves Initial Test Held at 81 PSID Closed Tight LI Leaked LI Held at PSID Closed Tight LI Leaked Opened at ':5.4 PSID LI Did Not Open LI Air Inlet Opened at PSID LI Did not Open 1:1 Check Held PSID LI Leaked #1 #2 Closed Tight Leaked El LI - - LI - Pass Fail R E A R LI CLEANED REPLACED F1 Disc LI Spring LI Guide LI Seat LI 0-Ring(s) LI Module LI Rubber Kit 1:1 ___ LI CLEANED REPLACED LI Disc LI Spring LI Guide Seat LI 0-Ring(s) LI Module LI Rubber Kit 1:1 ___ LI CLEANED REPLACED LI Disc LI Spring LI Diaphragm LI Seat LI 0-Ring(s) LI Module LI Rubber Kit El __ LI CLEANED REPLACED LI Air Inlet Disc LI Airl Inlet Spring LI Check Disc LI Check Spring LI Float LI Diaphragm LI Rubber Kit LI ___ CLEANED REPLACED REPAIR Other LI LI LI LILI LI LI LI Other/Notes: /pprn+. RA gi USC 10th Edit. Final Test PSID LI Closed Tight PSID" LI Closed Tight LI Opened at PSID Air Inlet PSID CK Valve PSID Closed Tight LI LI Pass LI THE ABOVE REPORT IS CERTIFIED TO BE TRUE: 1A Tested By Date Certificate # Gage # Test Result Testing Company's Conatact Information $-It QpL. QPass P0 Box 2702 Fail Escondido, C4 . 92033 V/ EquaIAir Balance Company Menchie's Carlsbad CERTIFIED TEST; ADJUST; BALANCE REPORT Project Name: Menchie's Carlsbad Address: Bressi Ranch Village Center City: Carlsbad, CA 92009 Architect: David Boyce Engineer: N/S HVAC Contractor: Solid Construction NEBB Certified TAB Firm: Equal Air Balance Company Address: 357 East Arrow Highway, Suite 206 City: San Dimas, CA 91773 EAB Job #: 20226 Certification Number: 2910 License #: 1006492 Date: 8/3/2020 Technician: Matt Wood AIR BALANCE REPORT IS NOT VALID WITHOUT NEBB STAMP ABOVE EqiaIYIr Batance Company REPORT CERTIFICATION Project Name: Menchie's Carlsbad Certifying NEBB Qualified TAB Supervisor Erik Dlugajczyk Finn License Number 1006492 Expiration Date: 8/31/2021 Firm Certification Number 2910 Expiration Date: 3/31/2021 "THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTS THAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES. FROM DESIGN QUANTITIES, WHICH EXCEED NEBB TOLERANCES, ARE NOTED IN THE TEST - ADJUST - BALANCE REPORT PROJECT SUMMARY." 357 E. Arrow Hwy. Suite 206 San Dimas, CA 91773 Phone (714) 637-3500 Fax (714) 637-3050 Web: www.equalairbalance.com Specializing in testing and balancing of environmental systems Menchie's Carlsbad Certification 4-7 Symbol Sheet 8 Supply Fan Data Sheet: RTU - I 9 Outlet Sheet: RTU - I & AC - 1 10 Inlet Sheet: EF - 1 11 Coded Drawing Customer Name: EQUAL AIR BALANCE Calibration Date: 12-20-2019 Reference Number: Calibration Due: 12-20-2020 Instrument Manufacturer: ALNOR Calibration Fluid: AIR 8 14 . 7PSIA 70F Instrument Description: AIR FLOW TESTER Standard(s) Used: A220 DUE 5-2020 Model Number: EBT-721 & ACCESORIES NlST Traceability Per: 1520423238,1520501070 Serial Number: 90447006 Ambient Conditions: 762 minHGA, 45% RH 68F Rated Accuracy: + / - 3% RD + 5FPM Procedure Number: T. 0. 3 3K6 -4-1769-1 Accuracy Given: +1- .53% RD.; K=2 Certificate/.FileNumber: 452304.2019A AS REC./AS LEFT WITHIN SPECS. **-CALIBRATED WITH D.M. ACCESORIES ** INDICATED ACTUAL INDICATED ACTUAL INDICATED ACTUAL AIRFOIL AIRFOIL :J GRID GRID HOOD HOOD .FPM FPM FPM FPM CFM CFM 99 100 : 101 ioO 99 100 495 - 500 504 500 495 500 990 1000 1006 1000 792 800 1485 1500 1512 1500 1188 1200 1980 2000 2017 2000 1483 1500 3975 4000 '2420 2400 1977 2000 AL72-TI H2O 1-120 1.00 1.00 DEG.F DEG.F 10.00 10.00 68.1 . 68.3 20.00 20.00 90.1 90.4 60.00 60.00 P1TOT TUBE I PITOT TIME % RJ-I(AL72-TH1,) % RH 1000 TO 10000, 1000 TO 10000 32.3 33.1 2510 2500 44.7 45.2 6020 6000 76.3 77.3 CERtWICAEE OF CALIBRATION All 'instruments used in the formance of' the shown calibration have traceability to the National Institute of Standards and Technology (NIST). The uncertaint' ratio between the calibration standards (DM.STD.) used and the unit under test (UUT) is a minimum of 4:1. unless otherwise noted. Calibration has been performed per the shown procedure number., in accordance with ISO 10012:2003. ISO 17025:2005. ANSIINCSL-Z-540.3. and/or MIL-STD-45662A. Test methods: AP12530-92 & ASME MFC-3M.1989. Dick Munns Company • 11133 Winners Circle • Los Alamitos, CA 90720 Phone(714)827-1215 - 'T'ICIibrndonC,ihfcImll mi b irp,odwcd C.' u,i,irs,uI.,IhouI ippio*.il b DICK MUMNS COMPANY rhcd.11a mtn,tppImoiiI to ow iminnimmImnthbI,d,d nad mikriI slaw cnida.morcdibrnon Pate: Approved By: . Calibration Tcchnician Page 1 of_J Lit :EquaiAur'EaIance.Oompariy, - -•- Air Symbol Sheet ACU Air Conditioning Unit LAT Leaving Air Temperature AK Free Area Factor LD Linear Diffuser ATM Atmosphere LFD Laminar Floor Diffuser BHP Brake Horse Power LWT Leaving Water Temperature CAV Constant Air Volume MAT Mixed Air Temperature CD Ceiling Diffuser MB Mixing Box CER Ceiling Exhaust Register NA Not Applicable CFM Cubic Feet per Minute NI Not Installed CHWR Chilled Water Return NL Not Listed CHWS Chilled Water Supply NVL No Valid Location CO Cooling Only NM Not Measured CRR Ceiling Return Register NR Not Read CSG Ceiling Supply Grille -NS Not Specified CWR Condenser Water Return OSA Outside Air CWS Condenser Water Supply R.A Reverse Acting D.A. Direct Acting RA Return Air DNA Data Not Available RAG Return Air Grille DO Duct Opening RAR Return Air Register DT Duct Traverse RD Round Diffuser EAG Exhaust Air Grille RH Re-Heat EAR Exhaust Air Register RPM Revolutions per Minute EAT Entering Air Temperature SA Supply Air EF Exhaust Fan SAG Supply Air Grille EG Exhaust Grille SAR Supply Air Register ESP External Static Pressure SAV Supply Air Valve EWT Entering Water Temperature SEF Smoke Evac Fan EXH Exhaust SP Static Pressure FC Fan Coil SW Sidewall FLA Full Load Amps SWG Sidewall Grille FP Fan Powered TBD To Be Determined FPM Feet per Minute TSP Total Static Pressure GEX General Exhaust T-STAT Thermostat GF Grease Filter UA ULPA Filter HF Hepa Filter V Volts HP Horse Power VAV Variable Air Volume HWR Hot Water Return VP Velocity Pressure HWS Hot Water Supply WER Wall Exhaust Register 8 _ A.. Equal •Atr Project Name: Betarióe Date: Job #: Readings By: Menchie's Carlsbad 8/3/2020 20226 Matt Wood AIR MOVING EQUIPMENT TEST SHEET Supply Fan Data UNIT DATA RTU - I AC - I Equipment Location Roof Kitchen Area Served Sales and Stock Room Kitchen Equipment Manufacturer ACROAIRE Mitsubishi Model I PHD336000H000C1 AUUI2RLF Serial Number I C144002736 KVA023162 FAN TEST DATA SPECIFIED ACTUAL SPECIFIED ACTUAL Supply Air CFM - FAN 1200 NVL 530 NVL Supply Air CFM - OUTLET 1200 1157 530 546 Return Air CFM - INLETS 948 876 530 546 Outside Air CFM 252 263 NS NA Static Pressure - Total NS NA NS NA Discharge TSP NS NA NS NA Suction TSP NS NA NS NA Static Pressure - External NS 0.47' NS NA Discharge ESP NS 0.29" NS NA Suction ESP NS 0.18" NS NA Fan RPM NS High NS High MOTOR DATA SPECIFIED ACTUAL SPECIFIED ACTUAL Motor Manufacturer NS NA NS NA Frame NS NA NS NA Motor H.P. I S.F. NS 3/4/1.0 NS NA /1.0 Voltage/Phase/HZ 208/1/60 209 208/1/60 210 Amperage 6.0 5.2 0.2 0.18 Motor RPM Vari High Vari High VFD Speed / Motor Speed NS NA NS NA Mtr. Sheave & Shaft Size Direct Drive Direct Drive Fan Sheave & Shaft Size Direct Drive Direct Drive Sheave t Dis. I Position Direct Drive Direct Drive No. Belts I Make / Size Direct Drive Direct Drive Notes: Ni$ip CERTIFIED MEMBER - NATIONAL ENVIRONMENTAL BALANCING BUREAU TEST AND BALANCE REPORT Equal Air Balance Company DIFFUSER AND GRILLE TEST L. Menchie's Carlsbad Job No.: 20226 Readings by: Matt Wood Date: 8/3/2020 iII1 [11 I1Ii••['ii4i II - flr lti — 1TTJ' Notes: 10 m4ill CERTIFIED MEMBER - NATIONAL ENVIRONMENTAL BALANCING BUREAU 1. • ,••-., ap .• TEST AND BALANCE REPORT Equal Air Balance Company DIFFUSER AND GRILLE TEST Menchie's Carlsbad Job No.: 20226 Readings by: Mall Wood Date: 8/3/2020 II 11 U1II I••['iEI IJ.']:l ',•L. I (1U Notes: 11 N11B1B CERTIFIED MEMBER - NATIONAL ENVIRONMENTAL BALANCING BUREAU - - Im p P CpAll m I CA I Jill !I 12115 1 A CC - C C C 4 C C I jl C; m C) A A ' - '. ' CR r m will .5 C WTH !111111Wl pq U A If Is hCl CCC 1111 !i!II IjUji,C C A go 1111 - I lilt 1111111 i A A A9CC II Ig 111 z A 9 A ir IRC; b CL! A b ; h m : h 111, ih C Jill A C AC CC C C - -ill A Hall C C5 A A 21 C 11 bA! !!C CC C C Ni C 4 C A I Cl l b BRESSI RANCH VILLAGE CENTER I CMACA.99 I E IS RECE\jED 0 Ito MAY 18 2020 7. CITY OF CARLSBAD BUILDING DIVISION Director (Countp of 6an 1 ttjo AMY HARBERT Assistant Director DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD AND HOUSING DIVISION P.O. BOX 129261, SAN DIEGO, CA 92112-9261 Phone: (858) 505-6659 FAX: (858) 505-6824 1(800) 253-9933 www.sdcdeh.org PLAN APPROVAL SHEET DBA: MENCHIE'S FROZEN YOGURT DATE: 3/19/20 SITE: 2659 GATEWAY RD D107 CARLSBAD 92009 Pc #: DEH2020-FFPP-012263 BUSINESS OWNER: SAA Plans are approved contingent upon the following: )Department of Environmental Health (DEH) stamped plans shall be maintained at the jobsite and available for review a the time of the inspectionJ 2) Changes to equipment layout, menu, or application must be submitted for approval. Changes made without approval will make the olan anoroval null and void. 4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency. 5) Upon completion of 50%-80% of construction, email: celeste.penn@sdcountv.ca.gov to schedule an inspection. In lieu of a plumbing inspection by DEH, ensure that the plumbing is constructed to these standards: Floor sinks shall be installed '/2 exposed and equipped with an appropriate grill cover if no access is provided for cleaning. Drain lines shall slope ¼" per foot, shall not exceed 15' in length and shall terminate a minimum of!" above the floor sink with a legal air gap or otherwise approved by the enforcing agency. Drain lines shall not intersect walkways or door ways. No condensate drainage of any kind can drain to the mop sink. 3-compartment sinks, preparation sinks, dump sinks, and any other plumbed equipment must drain indirect to a floor sink. Grease traps/interceptors, if required by the local waste water authority must be located outside of the food preparation, food storage, or warewashing areas. Floor surfaces must be sloped 1:50 to required floor drains. Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed in a chase so as to facilitate cleaning. 6) Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of successful completion of this course is to be furnished at the final inspection. 7) All equipment is to be in place and functional. At the time when the final inspection is requested, the facility shall have all utilities operational and all refrigeration shall have an ambient air temperature of 38°F or below and shall be equipped with a thermometer accurate to +1- 2°F in the warmest section of the unit. 8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashesround4pipes and conduits with Plans reviewed by: Celeste Penn, REHS EMAIL: celeste.penn(sdcountv.ca.qov. AT LEAST 10 WORKING DAYS IN ADVANCE TO SCHEDULEINSPECTIONS.A FINAL INSPECTION MUST BE CONDUCTED AND AN ENVIRONMENTAL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENIN'ANDLOPERATING THIS FOOD ESTABLISHMENT. "Environmental and public health through leadership, partnership and science" SAN DIEGO REGIONAL OFFICE USE ONLY HAZARDOUS MATERIALS PLAN CHECK # QUESTIONNAIRE BP DATE I I Business Name Business Contact Telephone # Menchie's Frozen Yogurt Tim McGinn Project Address City State Zip Code APN# 2629 Gateway Road D107, Carlsbad, CA 92009 Mailing Address City• State • Zip Code Plan File# Project Contact Applicant E-mail Telephone # Ashley Rosado arosodo@interplanllc.com - 407.645.5008 The following questions represent the facility's activities, NOT tne Specific project aescruptuon. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for protects within the City of San DIecio: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. Flammable Solids 8. Unstable Reactives 12. •Radloactives I the answer to any Diego, CA 92123. Call (858) 505.6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: YES NO (for new construction or remodeling projects) 0 NJ Is your business listed on the reverse side of this form? (check all that apply). 0 NJ Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 NI Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons. .500 pounds and/or 200 cubic feet? 0 NJ Will your business store or handle carcinogenslreproductive toxins in any quantity? 0 .NJ Will your business use an existing or install an underground storage tank? 0 NJ Will your business Store or handle Regulated Substances (CalARP)? 0 NJ Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 NJ Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or areater than 1.320 gallons? (California's Aboveground Petroleum Storage Act). CalARP. Exempt Date initials E3 CalARP Required Date initials CalARP Complete Date initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 pocdcomp(ãtsdcountv.ca.aov (858) 586-2650). [*No stamp required if 01 Yes and 03 Yes MrLdQ4-08 No!. The following questions are intended to identify the majority of air pollution Issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. (Excludes garages & small outbuildings.] YES NO 0 lI Will the project disturb 160 square feet or more of existing building materials? 0 NI Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 NI (ANSWER ONLY IF QUESTION I or IS YES) Has an asbestos surveybeen performed by a Certified Asbestos Consultant or Site Surveillance Teóhñician? 0 l (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commending asbestos removal. 0 NI Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (w.sdaøcd.orgIinfo/facts/permits.odfl for typical equipment requiring an APCD permit. 0 Q (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school Briefly describe business activities: Briefly describe proposed project: Self Served Frozen Yogurt Shop Interior Buildout of Existing Space I declare under penalty of perjury that to the best of my knowledge and belief tHe responses made herein are true and correct. Ashley Rosado - Agent Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date. FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-i1MD' APCD COUNTY-HMD APCD COUNTY-HMD APCD RECEIVE) B C IJiLDINC, MAY 182020 TYoFc.t -A stamp in this PDX oniv exempts ousinesses irum curnpiculiv UI UPUCKLIP IV a HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY wMMVAUR 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. Automobile Detailers Barber/Beauty Shops Business/Sales Offices Cleaning Services Carpet/Upholstery Childcare Facilities Churches Community Centers Consulting Services Contractors Counseling Services Educational Services (no auto repair/film developing) Financial Institutions/Services Fitness Centers Gas Stations (no carwash/auto repair) Grocery Stores (no film developing) Residential based Businesses Hotels/Motels (no laundry) Laundromats Libraries Medical Offices (no x-ray developing) Mortuaries Museums Nail Salons Nursing Homes Office Buildings (no, process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services (no car wash/auto repair) Public Storage Facilities e Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) CERTIFICATION STATEMENT I certify that the information above is true and correct to the best of my knowledge. Signature: 44%y./94c2lô Agent Print Name:Ashley Rosado DATE: 2.12.20 Facility Contact:________________________________ Title:_________________________________________ ENCINA WASTEWATER AUTHORITY 6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinaipa.com Page'2 of 2 (city of Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov PURPOSE This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form + Patio I + Decks I •:• PME (w/o panel upgrade) + Pool A If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. A Details on CAP ordinance requirements are available on the city's website. 4 A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webaae and download the latest form. Application Information Project Name/Building Permit No.: Mencnles Frozen Yogurt BP No.: Property Address/APN: 26rGateway Road Dl 07, Carlsbad, CA 92009 Applicant Name/Co.: Ashley Rosado / Interplan LLC Applicant Address: 604 Courtland Street Suite 100, Orlando, FL 32804 Contact Phone: 407.645.5008 Contact Email: arosado@interplanllc.com Contact information of person completing this checklist (if different than above): Name: Contact Phone: Company name/address: Contact Email: Applicant Signature: /9S44 Agent Date: 2.12.20 6-50 Page 1 of 6 Revised 08119