Loading...
HomeMy WebLinkAbout1738 SCHOONER WAY; ; CBR2017-1434; PermitCity 0f Carlsbad Residential Permit Print Date: 03/22/2019 . Permit No: CBR2017-1434 Job Address: 1738 Schooner Way Permit Type: BLDG-Residential Work Class: Addition Status: Closed - Finaled Parcel No: 2073200600 Lot #: Applied: 06/26/2017 Valuation: $95,277.80 Reference U: Issued: 05/29/2018 Occupancy Group: Construction Type: Permit Finaled: U Dwelling Units: Bathrooms: . Inspector: AKrog Bedrooms: Orig. Plan Check U: Final Plan Check U: Inspection: 3/22/2019 11:08:38AM Project Title: Description: SUNDSETH: ADD 499 SF FOR BEDROOM 3 & 4 I/REMODEL 150 SF MASTER BATH & CLOSET Applicant: . Owner: BROOKS A WORTHING COOWNER SUNDSETH KEONI J AND GEANIE H P0 Box 1041 1738 Schooner Way Carlsbad, CA 92018-1041 CARLSBAD, CA 92008 760-729-3965 BUILDING PERMIT FEE ($2000+) , $609.78 BUILDING PLAN CHECK FEE (BLDG) $480.44 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $43.00 GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION . $166.00 MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $52.00 PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL . $80.00 5B1473 GREEN BUILDING STATE STANDARDS FEE . . $4.00 STRONG MOTION-RESIDENTIAL $12.39 SWPPP INSPECTION FEE TIER 1- Medium BLDG . $232.00 SWPPP PLAN REVIEW FEE TIER 1- MEDIUM $55.00 Total Fees: $1,734.61 Total Payments To Date: $1,734.61 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: []PLANNING 0 ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH 0 HAZMATIAPCD Building Permit Application rrbty of k— 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Cdlsbad email: building@carlsbadca.gov www.carlsbadca.gov Plan Check No.QfRZ %-I- t'..M Est. Value Plan Ck. Deposit I Date lo - - t( Iswppp I JOB ADDRESS 1-720 4UNITS SUITE#/SPACE#/UNITI I I APN I - (oI) - - 00 CT/PROJECT C LOT C PHASE C # BEDROOMS BATHR I OO TENANT BUSINESS NAME CONSTR. TYPE I __. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) (q 4-1 dèEo kv,4cl 2I6 4001< t6i,05;0 / V1 444s . doolik 4=9 EXISTING USE J PROPOSED USE GARAGE (SF) PATIOS (S F) I DECKS (SF) I IYESDC FIREPLACE NO[:] lAIR CONDITIONING YES I:JNO I FIRE SPRINK' ERS I YES APPLICANT NAME Primary Contact 'B A U),wi4 I TYOWNER PROPER -t & e*u' e ADDRESS ?O e I 64 ADDRESS 1-me Js~kcvrjev WA-1 CITY STATE ZIPwI6 CITY STATE ZIP PHONE 7(0 IL'1 I FAX 1' 07 '4 PHONE IFAX I . EMAIL SA Wo c-Wi EMAIL DESIGN PROFESSIONA CONTRACTOR BUS. NAME A. tAJ ADDRESS x i4-I __o ____ ADDRESS I(_ io1-' ''_____________________________ 'STATE ZI CITY STATE CITY ZIP t PHONE -700 1Z!O IFAX -72tO1 PHONE FAX 116721 t774 A VJo4 '-14i Cowl EMAIL EA utIb(*fr I I STATE LIC. C STATE LIC.# coms Cli? BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish o repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commendIng with Section 7000 of Division 30f the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). PL1?OØ{J Workers' Compensation Declaration: I here by affirm under penally of pe4ur, one of the lbllo wing declarations: Ell have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. have and will maintain workers' compensation, as required by Section 37000? the Labor Code, for the performance of the work for which this permit Is issued. My workers' compensa n rance carder and policy number are: Insurance Co. _C4't'tiC i =W a. Policy No. tjJ C ACX3 Expiration Date 71 i Ti B N section need not be completed if thermit is for one hundred dollars ($100) or less. Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (116100,000), In addition to the cost of compensation, damages vided n Section 060? the L code, Interest and attorney's fees. CONTRACTOR SIGNATURE 4j°-.- - DAGENT DATE ®GOoOWO1E)OD @G04 . - - I hereby affirm that am exempt from Contractor's Ucense Law for the following reason I, as owner of the property or my employees with wages as their sole compens n, will do the wo and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves th on, and who doe such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement is sold within one year of comple n, the ownerS erwill have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section _____________Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes ONO 2.1(have !have not) signed an application fora building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, bull have hired the following person to coordinate, supervise and provide the major work (include name! address! phone Icontractors' license number): twill provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone! type of work): 5PR0PERTY OWNER SIGNATURE []AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? C11 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes Cl No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes Cl No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address Icerlifythati have mad the application and state thatthe above Information Is conectand thatthe information on the plans is accurate. I agree to oompkwfth all Cilyordinances and State Ian relartingtD buildingoonstruction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA M OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3stories in height EXPIRATION: Every permit issued by the BuildingcifdalunderthepronsoftiuisCodeshallexpirebylimitationandbecomenullandvokl tithe building or work authorized bysuch permit Is not commenced within 180 days from the date ofsudr permit orifthebulii orwork au bysri permit is s or abandoned at any time after the work is comencedfor a period of 180 days (Sedion 106.4A Uniform Building Code). M'APPLICANT'S SIGNATURE JA DATE (49 / 29 1' STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. • .i (Comm ercial Projects Only) Fax (760) 602-8560, Email buildinacarIsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only), CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS 0 PICKUP. o CONTACT (Listed above) a OCCUPANT (Listed above) a CONTRACTOR (On Pg. 1) a ASSOCIATED CB # O MAIL TO: a CONTACT (Listed above) a OCCUPANT (Listed above) 0 CONTRACTOR (On Pg. 1) a NO CHANGE IN USE / NO CONSTRUCTION 0 MAIL/ FAX TO OTHER: a CHANGE OF USE/ NO CONSTRUCTION ,.gAPPLICANTS SIGNATURE DATE Permit Type: BLDG-Residential Application Date: 06/26/2017 Owner: COOWNER SUNDSETH KEONI J AND GEANIEH Work Class: Addition Issue Date: 05/29/2018 Subdivision: CARLSBAD TCT#72-18 LJNIT#01, Status: Closed •Finaled Expiration Date: 09/16/2019 Address: 1738 Schooner Way Carlsbad, CA 92008-3623 IVR Number: 4643 - Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 01/02/2019 0110212019 BLDG-22 080191.2018 Sewer/Water Service 0110312019 0110312019 BLDG47 Interior 080344-2019 LathlDrywail BLDG-18 Exterior 080411-2019 Lath/Drywall 0111012019 0111012019 BLDG-17 interior 080995-2019 Lath/Drywall Checklist Item BLDG-Building Deficiency BLDG-27 Shower 081100-2019 Pan/Tubs 03120/2019 03120/2019 BLDG-Final 086559.2019 Inspection Passed Andy Krogh Passed Andy Krogh Passed Andy Krogh Passed Andy Krogh COMMENTS - Shower Passed Andy Krogh Partial Pass Andy Krogh Complete Complete Complete Complete Passed Yes Complete Reinspection Incomplete Checklist Item COMMENTS ' Passed BLDG-Building Deficiency Requires green building form, waste No - management with receipts, Ok to occupy BLDG-Plumbing Final Requires exterior clean out covers, requires No -hose Bibb vacuum breaker BLDG-Mechanical Final Yes BLDG-Structural Final -. Yes BLDG-Electrical Final Yes 0312212019 0312212019 BLDG-Final 086800-2019 Passed Chris Renfro Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Requires green building form, waste Yes management with receipts, oh to occupy BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Complete March 22, 2019 Page 2 of 2 Permit Type: BLDG-Residential . Application Date: 06/26/2017 Owner: COOWNER SUNDSETH KEONI J AND GEANIE H Work Class: Addition Issue Date: 05/29/2018 Subdivision: CARLSBAD TCT#72-18 UNlT#01 Status: Closed - Finaled Expiration Date: 09/16/2019 Address: 1738 Schooner Way Carlsbad, CA 92008-3623. IVR Number: 4643 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 0812912018 08129/2018 BLDG-21 068514-2018 Passed Andy Krogh Complete Underground/Under! loor Plumbing 09/04/2018 09104/2018 BLDG-66 Grout 068916-2018 Passed Andy Krogh Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Foundation . Yes 1011012018 10I1012018 BLDG-13 Shear 072724-2018 Failed-Construction Andy Krogh Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist Item COMMENTS Pissed BLDG-Building Deficiency. Requires special inspection and plan No change revision to show new door on north side of building by pool BLDG-15 072452.2018 Passed Andy Krogh Complete Roof/ReRoof (Patio) 12/1812018 12/1812018 BLDG-13 Shear 079097-2018 Failed Andy Krogh Reinspection Complete Panels/HO (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Missing approximately 60f shear on north . No east corner BLDG-Building. Deficiency Requires special inspection and plan No change revision to show new door on north side of building by pool 12/19/2018 12/19/2018 BLDG-13 Shear 079298-2018 Passed Andy Krogh PanelslHD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Requires special inspection and plan Yes change revision to show new door on north side of building by pool BLDG-Building Deficiency Missing approximately 6' of shear on north Yes east corner 12/20/2018 12/20/2018 BLDG-84 Rough 079447-2018 Passed Andy Krogh Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 .. Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout . Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers Complete Complete March 22, 2019 - Page 1 of 2 City of Carlsbad cbR2017-1434 July 10, 2017 _ k f' A W :Devè61,ment Services SPECIAL INSPE0 A~01, "4w Building Division C I TV OF AGREEMENT 1635 Faraday Avenue B 760-602-2719 CARLSAD B-45 WWW.0 In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. 'roject/Permit: Z() 17 't3 4 Project Address:_ 7 'f) C(9I THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZED AGENT. Please check if you are Owner-Builder . (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please (LAS,) Mailing Phone: 310 2--027( lam: MPropertyOwner aProperty Owner's Agent of Record DArchitect of Record DEngineer of Record State of California Registration Number Expiration Date: AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of CaliforniaBuilding Code. special inst Signature: ions noted the roved plans and, as required by the MA'c 7jl' CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor/builder! owner-builder. Contractor's Company Name:- 64 LJ, 1_(.44 i/Uti ijU (.. Please check If you are Owner-Builder 0 Name: (Please print) Is (First) Mailing Address: P1) 60)0 10 q C-&L, 4-t (.4- of 7OI S Email:_ i11.t€LUc. d44OO. C.#QsW Phone: ( 7z.g 3' State of California Contractor's License Number: ' q Expiration Date: _1'_/_Z0 O I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. I will Provide a final reriort / letter in compliance with CBC Section 1704.1.2 orior to reauestinu final inspection. A B-45 Page 1 of I Rev. 08/11 EsGil Corporation In Partners/lip wit/i government for Building Safety DATE: 05/21118 ci APPLICANT U JURIS. JURISDICTION: c ity-of-Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: cbR2017-1434 SET: IV PROJECT ADDRESS: 1738 Schooner Way PROJECT NAME: Bedroom Addition, Nook Extension and M. Bath Remodel for and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. LIII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: Brooks Worthing . EsGil Corporation staff did not advise the applicant that the plan check has been completed. LI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Brooks Worthing Telephone #: 760-729-3965 Date contacted:— (b ) Email: baworthinginc@yahoo.com Telephone Fax In Person REMARKS Trusses have been deferred. By: Javier Snider (RM) Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 05/14/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partners flip wit/i government for Bui&(ing Safety DATE: 04/30/18 JURISDICTION: City of Carlsbad PLAN CHECK NO.: cbR2017-1434 UA'PLICANT JURIS. U PLAN REVIEWER U FILE SET: III PROJECT ADDRESS: 1738 Schooner Way PROJECT NAME: Bedroom Addition, Nook Extension and M. Bath Remodel for and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Brooks Worthing liii EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Brooks Woring Telephone #: 760-729-3965 Date contacted: -4b (by() Email: baworthinginc@yahoo.com ail)( TeIephork Fax In Person LI REMARKS: By: Javier Snider (RM) Enclosures: EsGil Corporation EJGA DEJDMB DPC 04/23/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad cbR2017-1434 04/30/18 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from .the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). Please sign all plan sheets. FOUNDATION AND FRAMING Verify all A trusses, check support points on plans. Please check sheet 5 and 6 details. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). CBC Sectibn 107.3.4.1. Please review truss calculations. Ensure that calculation, and diagram match sheet 6 of plans. Continued City of Carlsbad cbR2017-1434 04130/18 MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L3 No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Javier Snider (RM) at EsGil Corporation. Thank you. EsGil Corporation In tFartnership with government for gui(ding Safety DATE: 03/20/2018 JURISDICTION: City of Carlsbad PLAN CHECK NO.: cbR2017-1434 SET: II PROJECT ADDRESS: 1738 Schooner Way P_ V ' J URIS. U PLAN REVIEWER U FILE PROJECT NAME: Bedroom Addition, Nook Extension and M. Bath Remodel for and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Brooks Worthing EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Brooks Worthing/c,,.7 Telephone #: 760-729-3965 Date contacted: 4xia (by: Email: baworthinginc@yahoo.com eMail TelephoneV Fax In Person LI REMARKS: S By: Javier Snider (RM) Enclosures: EsGil Corporation El GA El EJ 0 MB 0 PC 03/12/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad cbR2017-1434 03/20/2018 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). Please sign all plan sheets. FOUNDATION AND FRAMING 14. Verify all A trusses, check support points on plans. Spans on glans are 12 ft. while calculations show 11 ft., A truss on calculations sheet do not show overhang. Please correct. 19. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2). a) Expansion/Epoxy anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. Please indicate on plans. City of Carlsbad cbR2017-1434 03/20/2018 MISCELLANEOUS If special inspection is required, the designer shall complete the city's "Special Inspection Agreement" found at the end of this list. Not included. Applicant to complete and submit to the City of Carlsbad city's waste management forms found at the end of this list. Not included. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or.detail number, calculation page, etc. . Please indicate here if any changes have been made to the plans that are not a result of corrections from this list.. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes E3 No L3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Javier Snider (RM) at EsGil Corporation. Thank you. EsGil Corporation In (Partners flip with government for (Building Safety DATE: July io; 2017 JURISDICTION: City of Carlsbad PLAN CHECK NO.: cbR2017-1434 SET:I PROJECT ADDRESS:' 1738 Schooner Way U}PPLICANT ..el JURIS. U PLAN REVIEWER U FILE PROJECT NAME:' Bedroom Addition, Nook Extension and M. Bath Remodel for and Remodel The plans transmitted herewith have been corrected where necessary and, substantially comply with the jurisdiction's codes. F-1 The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith. is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Brooks Worthing EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Brooks Worthing Telephone #: 760-729-3965 Date contacted7/i1t, (by4.S Email: baworthingincyahoo.com Iephon_, Fax In Person By: Rich Moreno Enclosures: EsGil Corporation 0 G DEJDMB E] PC June 29, 2017 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad cbR2017-1434 July 10, 2017 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: ëbR2017-1434 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 1738 Schooner Way FLOOR AREA: Addition: 647 sq-ft Remodel: 150 sq-ft REMARKS: DATE PLANS RECEIVED BY JURISDICTION: June 26, 2017 DATE INITIAL PLAN REVIEW COMPLETED: July 10, 2017 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: 12-ft DATE PLANS RECEIVED BY ESGIL CORPORATION: June 29, 2017 PLAN REVIEWER: Rich Moreno This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad cbR2017-1434 July 10, 2017 . PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). Permit application states 647 sq-ft addition and 150 sq-ft remodel. Plans show close to 700 sq-ft addition and about 230 sq-ft remodel. Please clarify project areas on resubmittal. All new residential buildings, including additions, require a soils report. An update letter is required if the report is more than 3 years old. If a room addition is less than 500 sq. ft. in area and only one story, then a soils report is not required. The maximum allowable soil bearing value used in any design must be 1500 psf for this exception. Under this condition, Esgil staff should advise the City (upon final transmittal) to place their "soils notice" stamp on the plans. Carlsbad has ruled that a stand-alone accessory dwelling unit, if under 500 square feet, may also qualify for this exception. . GENERAL RESIDENTIAL REQUIREMENTS Is existing exterior window between Kitchen and Nook to remain? Not typical construction. Sleeping rooms shall have a window or exterior door for emergency escape. Section R310. a) The bottom of the clear opening shall not exceed 44" above the floor. Do not measure to the window sill. This generally applies to windows that have a height of 3' or less. See the figure below to see the correct method of measurement. Please dimension on elevations. Landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served City of Carlsbad cbR2017-1434 July 10, 2017 and have a minimum or 36-inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ¼-inch per. foot. Landings or finished floors shall not be more than 1.5 inches lower than the top of the threshold for outward swinging exterior doors or 7.75" for doors that do not swing outwards. R311.3. Overflow roof drains shall terminate in an area where they will be readily visible and will not cause damage to the building. If the roof drain terminates through a wall, the overflow drain shall terminate 12" minimum above the roof drain. Policy 84-35. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area (if over 30 sq. ft.), shall be located in a hallway or other readily accessible location and 30" headroom clearance Is required above the opening. Section R807.1. . FOUNDATION AND FRAMING Detail F does not reflect new to existing joining of foundation. Please provide pertaining detail. It appears that new foundation is being proposed to abut to existing continuous footing on foundation plans. Please clarify. Detail E for retrofitting anchors should be detail G. See left wall line. Provide standard SSW connection and foundation detail sheets. Check section callouts and referenced section on A-2. Also, provide traverse section Nook. Verify all A trusses, check support points on plans. For conventional framing: each braced panel must have a minimum length of 4- ft. Per section R602.10.2.3. For conventional framing: bracing wall lines must be spaced no more than 25-ft apart. see Table R602.10.1.3. By observation, it appears that this residence had previous work done for an open floor plan. The wall line aligned with the post at kitchen island(?) needs structural calculations to verify that there sufficient lateral bracing will be provided for structure. a) Show footing for post at kitchen. The intention for strap ties is to provide tension between connecting members. Please check that all bent strap ties shown on plans are shown straight. Also, City of Carlsbad cb1t2017-1434 July 10, 2017 provide and reference connection detail for strap ties connecting double top plate to rafters where it may pertain. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2) / a) Expansion/Epoxy anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. Show strap ties. at discontinuous top plates along right wall lines. . MECHANICAL 21: Show on the plans the location, type and size (Btu's) of all heating and cooling appliances or systems. 22. Every dwelling unit shall be provided with heating facilities capable, of maintaining a room temperature of 68 degrees F at a location 3 feet above the floor and 2 feet from exterior walls in all habitable rooms. Show basis for compliance. CRC 303.9. . ELECTRICAL 23. Note on the plans that receptacle outlet locations will comply with CECArticle 210.52. 24. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 - a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). , b) , Weather resistant type for receptacles installed in damp or wet locations (outside). 25. Will light at exterior right door be affected by this project? Could not verify location on plans. , . RESIDENTIAL GREEN-BUILDING STANDARDS 26. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan; perCGC Section 4.408.2. . ENERGY CONSERVATION 27. Please coordinate building direction on energy plans. Rights walls are shown as front walls, etc. ' 28. Energy code section on the cover sheet should be for the-2016 Energy Code. City of Carlsbad cbR2017-1434 July 10, 2017 29. When replacing or modifying the mechanical system: If more than 40' of new ductwork is installed in unconditioned space, HERS inspection is required for both existing and new duct sealing. Replacement of mechanical equipment (air handler, condensing unit of an air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger) requires HERS inspection. Note: The CFI R-ALT-HVAC form may be submitted at the final inspection, it is not required at initial plan submittal. If pertains: Include on the Title Sheet of the plans the following statementi. "Compliance with the documentation requirements of the 2016 Energy Efficiency Standards is necessary for this project. Registered, signed, and dated copies of the appropriate CFI R, CF2R, and CF3R forms shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." Include all applicable sections of the (MFI R) RMS-1 form or the specifications contained thereon with the plans. Residential Energy Lighting Requirements: ES 150.0(k) All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) . MISCELLANEOUS If special inspection is required, the designer shall complete the city's "Special Inspection Agreement" found at the end of this list. Applicant to complete and submit to the City of Carlsbad city's waste management forms found at the end of this list. If there is no complying barrier between the pool proposed new door, please show how compliance with section AGI 00.2 for pool safety will be achieved. (ie. exit alarm; self-closing, self-latching device with the release at least 54" from the floor, etc.). To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. City of Carlsbad cbR2017-1434 July 10, 2017 40. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: YesO No 41. The.jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Rich Moreno at EsGil Corporation. Thank you. City of Carlsbad cbR2017-1434 July 10, 2017 (DO NOT PAY— THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: cbR2017-1434 PREPARED BY: Rich Moreno DATE: July 10, 2017 BUILDING ADDRESS: 1738 Schooner Way BUILDING OCCUPANCY: R-3/U BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Addition 697 169.50 118,142 Remodel 230 46.51 10,697 Air Conditioning Fire Sprinklers TOTAL VALUE 128,839 Jurisdiction Code Icb IBy Ordinance I - ....................- $729.01I Bldg. Permit Fee by Ordinance V .P' __-j I $473.86 I Type of Review: El Complete Review E Structural Only D Other. Repetitive Fee 1 Repeats Hourly Hr. @ * EsGil Fee I $408.251 Comments: In addition to the above fee, an additional fee of $43 is due (1/2 hour © $86/hr.) for the CalGreen review. Sheet I of I macvalue.doc + City of Carlsbad Print Date: 08/27/2019 Permit No: PREV2018-0277 Work Class: Residential Permit Revisi Status: Closed - Finaled Lot #: Applied: 10/31/2018 Reference #: Issued: 12/11/2018 Construction Type Permit 08/27/2019 Finaled: Bathrooms: Inspector: AKrog Orig. Plan Check #: CBR2017-1434 Final Plan Check #: Inspection: Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 1738 Schooner Way BLDG-Permit Revision 2073200600 $ 0.00 Project Title: Description: SUNDSETI-I: ADD BAY WINDOWS Applicant: Owner: BROOKS A WORTHING COOWNER SUNDSETH KEONI J AND GEANIE H• P0 Box 1041 1738 Schooner Way Carlsbad, CA 92018-1041 CARLSBAD, CA 92008 760-729-3965 FEE AMOUNT BUILDING PLAN CHECK REVISION ADMIN FEE $35.00 MANUAL BUILDING PLAN CHECK FEE $225.00 Total Fees: $ 260.00 Total Payments To Date: $ 260.00 'Balance Due: $0.00 Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1760-602-8560 f I www.carlsbadca.gov (city of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-1.5 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Numb7M - t Plan Revision NumberIq/c9OJI Oc??? Project Address (1 3€ 4bOC4t General Scope of Revision/Deferred Submittal: z- CONTACT CONTACT INFORMATION: Name M-euA- Phone 70o 1 a674,15 Fax? '?Z 0-7e4 Address_ Aii City C* Zip Email Address f27 A 9.A4W, L"OYl Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Plans Calculations Soils E Energy I1 Other 2. Describe revisions in detail 3. List page(s) where each revision is shown 19 OI* Does this revision, in any way, alter the exterior of the project? "Yes No Does this revision add ANY new floor area(s)? E1 Yes No Does this revision affect any fire related issues? fl Yes N, No Is this a complete set? LI Yes 1"No £Signature_>( Date 1635 Faraday Avenue, Carlsbad, CA 92008 : 760-602-2719 f: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsGil A SAFEbuiItCompany DATE: 12/03/18 0 APPLICANT RIS. JURlSDlCTIOft—Cat1sbiãdI7 PLAN CHECK #.: CBR2017-1434.rev(2018-0277) SET: IA PROJECT ADDRESS: 1738 Schooner Way PROJECT NAME: Addition Revision for the Sundseth Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Alena Blasio EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Alena BI Telephone #: 760 729 3965 Date contacted: (y(7 Email: baworthinginc@yahoo.com Mail Telephone Fax IVP'rson LI REMARKS: By: Javier Snider Enclosures: EsGil 12/03/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 - EsGil A SAFEbuItt'Company DATE: 11/08/18 JURISDICTION: Carlsbad PLAN CHECK #.: CBR2017-1434.rev(2018-0277) PROJECT ADDRESS: 1738 Schooner Way O APPLICANT .2i URIS. SET: I PROJECT NAME: Addition Revision for the Sundseth Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. Eli The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Alena Blasio) EsGil staff dud not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Alena Blasio Telephone #: 760 729 3965 Date contacted: I LItIt (by) Email: baworthininc@yahoo.com ('ITeIhone Fax In Person 6 [J REMARKS: By: Javier Snider Enclosures: EsGil 11/01/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 ff Carlsbad CBR2017- 1434.rev(2018-0277) 11/08/18 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK #.: CBR2017-1434.rev(2018-0277) JURISDICTION: Carlsbad PROJECT ADDRESS: 1738 Schooner Way FLOOR AREA: STORIES: HEIGHT: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 11/08/18 DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/01/18 PLAN REVIEWER: Javier Snider FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2017- 1434.rev(2018-0277) 11/08/18 PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). To be checked on final. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). To be checked on final. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, carport, patio, deck and balcony. Section RI 06.2. New dimensions affect site plan. Please provide in revision. FOUNDATION REQUIREMENTS Provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. Addition now exceeds 500 sf provide a soils report per Carlsbad. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 14 Carlsbad CBR2017-1434.rev(2018-0277) 11108118 8. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes No L3 9. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Javier Snider at EsGil. Thank you. A Carlsbad CBR2017- 1434.rev(2018-0277) 11/08/18 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBR2017- 1434.rev(2018-0277) PREPARED BY: Javier Snider DATE: 11/08/18 BUILDING ADDRESS: 1738 Schooner Way BUILDING OCCUPANCY: R-3 1997 UBC Building Permit Fee V 1997 UBC Plan Check Fee (W I Type of Review: 0 Complete Review 0_Repetitive Fee 0 Other I Repeats ' Hourly EsGII Fee * Based on hourly rate o Structural Only 2 Hrs.@ $90.00 I $180.001 Comments: Sheet 1 of 1