HomeMy WebLinkAbout2243 PASEO SAUCEDAL; ; CB030756; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04-15-2003 Residential Permit Permit No: CB030756 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Applicant: Building Inspection Request Line (760) 602-2725 2243 PASEO SAUCEDAL CBAD RESDNTL Sub Type: 2552602900 Lot#: $3,840.00 Construction Type: 0 0 MEURER RESIDENCE Reference #: Structure Type: Bathrooms: RAD 0 NEW 0 CONVERT THIRD GARAGE TO BEDROOM Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check#: MEURER ANDREW&CHRISTINE ISSUED 03/14/2003 MOP 04/15/2003 04/15/2003 APS GENERAL CONTRACTORS STEA 2832 ·)4/15/03 0002 01 1950 KELLOGG AVE CARLSBAD 92008 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Total Fees: $133.26 2243 PASEO SAUCEDAL CGP CARLSBAD CA 92009 $53.49 Meter Size $0.00 Add'I Reel. Water Con. Fee $34.77 Meter Fee $0.00 SDCWAFee $0.00 CFO Payoff Fee $1.00 PFF $0.00 PFF (CFO Fund) $0.00 License Tax $0.00 License Tax (CFO Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFO Fund) $0.00 Sidewalk Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Housing Impact Fee $0.00 Housing lnlieu Fee Housing Credit Fee $0.00 Master Drainage Fee $0.00 Sewer Fee Additional Fees TOTAL PERMIT FEES Total Payments To Date: $34.77 Balance Due: FINAL APPROVAL Date: ()r-.) 0-03 Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $133.26 $98.49 NOTICE: Please t C that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exacti You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any f x i n f hi h I een iv n N Tl E ·mil r hi r to whi h h of limi i n h r vio I h rwi x ir d. 02 99,. 4Y .J)t; 1b IO PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 1, PROJECT INFORMATIO~ 1.143 PA5£o dA//(-£/JAL G4Rl,')6A/) Address (include Bldg/Suite #) Legal Description Lot No. Existing Use ~/?/' o,c FOR OFFICE USE ONLY ,,,-,r PLAN CHECK NO. e:g...-7 ~ 'O EST. VAL. ·\,Y1:f~ Plan Ck. Depos1tt{, "'l l Validated By • '.;:~ f&> Date ~ I (c,cz~ I Business Name (at this address) Phase No. 03/14/03 Total# of units ,? 34,77 , Description of Work SQ. FT. ·· · OfTiol'/ (3i1lLP offr G111 /3Eotao,+, / ,o - #of Stories # of Bathrooms / 2.i"ICONTACT PERSON tlf-different from applicant) I/. ' VfJ.l!AlO € O'Ct20&0/ /f/£0-A ,,ELLo?? z.. f'ARl5/JAJ 1J1-6ff5' Name Address City State/Zip Telephone# Fax# 3. APPLICANT Contractor □-Agent for Contractor 1 ' 1'. "· rt I - , JName Telephone# {X 4. PROPERTY OWNER C/.1R1:J /i1f llRef. r, dAII t.£/J&l C4ftSMl2 7tt1-GJ'l-2'177 Name 7 City Telephone# .. )s. , .. CONTRACTOR-~ COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant o a civil penalty of not more thaJI five hundred dollars [$5qg,J). AP5 6 l m s (". f. 0-A €/.{.(JC(r A/le: . v; z11ay d-,'-b Name Address City Stat /Zip Telephone # State License# /J--?JOI/Jj License Class /3 City Business License# }2j) J{;L/ Designer Name Address City State/Zip Telephone State License # _________ _ r,i 6. WORK£RS' COMP£NSATION 1, · Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: gJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers' compensation, as required by Section 3700 of the '3PW .>Jo,9~ issued. My worker's compensation insurance carrier and policy number are: b,). 'f "° '1 lnsu,ance Company 57JIT£ F qA'O Pol;cy fl! . e erformance of the work for which this permit is Expiration Date 0: -/-0 3 !THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, l shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: /house orkers' c mpe sation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred iti cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. DATE /o/A(C/1 /Z,,ZM3 (}, SIGN 7. I hereby affirm that 1 am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction {include name / address I phone number I contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): ________________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated {include name / address / phone number / type of work),,_----------------------------------------------------------- PROPERTY OWNER SIGNATURE ______________________ _ DATE __________ _ COMPLETE lHIS SECTION FOR NON•RESIOENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME _____________ _ LENDER'S ADDRESS __________________________ _ 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced ·thin 180 days from the dale of such permit or ii the building or work authorized by such permit is suspended or abandoned 1at any time after the work is co ced f od l;t days (Section 106.4.4 Uniform Building Code). ✓ APPLICANT'S SIGNATU DATE&!-(,4 /?, 2tJtJ3 7 WHITE: File YELLOW: Applicant PINK: Finance Inspection List . . . Permit#: CB030756 Type: RESDNTL RAD Date Inspection Item Inspector 05/29/2003 19 Final Structural JE 05/09/2003 17 Interior Lath/Drywall JE 05/07/2003 14 Frame/Steel/Bolting/Weldin JE 05/07/2003 14 Frame/Steel/Bolting/Weldin JE 05/07/2003 34 Rough Electric JE 05/07/2003 44 Rough/Ducts/Dampers JE 04/25/2003 11 Fig/Foundation/Piers JE Thursday, May 29, 2003 Act AP AP PA AP AP AP AP MEURER RESIDENCE CONVERT THIRD GARAGE TO BEDROOM Comments FINAL GARAGE DOOR TO BE ADJUSTED TO BE SELF CLOSING OK TO DRYWALL 1147-G2 OK TO PLACE CONCRETE Page 1 of 1 UNSCHEDULED BUILDING INSPECTION DATE PERMIT# C.8 03 o7..S-b . PLAN CHECK# ____ _ , DESCRIPTION ___ 1?._ .. 0_ ... __ r,o,,,V_Je_Al_l0_" ___________ _ CODE DESCRIPTION ACT EsGil Corporation In 'l'artnersfiip witfi (jovernment for (}JuiUing Safety DATE: April 7, 2003 JURISDICTION: Carlsbad PLAN CHECK NO.: 03-756 PROJECT ADDRESS: 2243 Paseo Saucedal PROJECT NAME: Meurer garage conversion SET: II □~ANT D JURIS. D REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ■ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ■ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person ( LJ,-'[) ■ REMARKS: OK to issue with the desi~ each page and placing a note on the plans about the smoke detector requireme~}Jehhe ;ttached for the language of the note. By: Bryan Zuppiger Enclosures: Esgil Corporation 0 GA O MB O EJ O PC 4/1/03 trnsmll.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 <;:arlsbad 03-756 April 7, 2003 1. · When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, show locations of permanently wired smoke detectors with battery backup in the new and existing construction or provide a note on the plans to this effect, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2: a) Inside each bedroom. b) Centrally located in corridor or area giving access to sleeping rooms. c) On each story. d) In the basement, if part of the dwelling unit. e) When sleeping rooms are upstairs, at the upper level in close proximity to the stair. f) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 310.9.1. EsGil Corporation In <Partnersnip witn <;ovemment for <Bui(ain9 Safety DATE: March 24, 2003 JURISDICTION: Carlsbad PLAN CHECK NO.: 03-756 PROJECT ADDRESS: 2243 Paseo Saucedal PROJECT NAME: Meurer garage conversion SET: I □~NT □ Cu.!RJ&,-1 □ PLAN REVIEWER □ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ■ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ■ The applicant's copy of the check list has been sent to: Donald O'Conner 1950-A Kellogg Avenue Carlsbad CA 92008 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ■ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Donald O'Conner Telephone#: 760 931 6869 ( 0-i A-JA, LAPti:') Date contacted:3/Jy /0..> (by: (c.-) Fax #: ( ::,c,,0) 9~1. lo99-> Mail /Telephone 0 REMARKS: Fax✓ In Person By: Bryan Zuppiger Esgil Corporation 0 GA O MB O EJ O PC Enclosures: 3/17/03 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 03-756 _March 24, 2003 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 03-756 JURISDICTION: Carlsbad PROJECT ADDRESS: 2243 Paseo Saucedal FLOOR AREA: 160' REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: March 24, 2003 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: n/a DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/17/03 PLAN REVIEWER: Bryan Zuppiger This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 03-756 March 24, 2003 • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, and (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The person responsible for their preparation must sign all final sheets of plans. (California Business and Professions Code). 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 4. Indicate on the Title Sheet of the plans the name of the legal owner and name of the person responsible for the preparation of the plans. Section 106.3.3. 5. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including the bedroom conversion. Section 106.3.3. 6. Is the new bedroom being accessed through the bathroom? • FOUNDATION REQUIREMENTS 7. Specify size, I.C.B.O. number and manufacturer of power driven pins, expansion anchors or epoxy anchors. Show edge and end distances and spacing. Section 106.3.3. 8. Please detail the concrete "berm". Carlsbad 03-756 March 24, 2003 • FIRE PROTECTION 9. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, show locations of permanently wired smoke detectors with battery backup in the new and existing construction or provide a note on the plans to this effect, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2: a) Inside each bedroom. b) Centrally located in corridor or area giving access to sleeping rooms. c) On each story. d) In the basement, if part of the dwelling unit. e) When sleeping rooms are upstairs, at the upper level in close proximity to the stair. f) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in fill sleeping areas of the unit. Section 310.9.1. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation. Thank you. Carlsbad 03-756 . March 24, 2003 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Bryan Zuppiger BUILDING ADDRESS: 2243 Paseo Saucedal BUILDING OCCUPANCY: R3/U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier conversion 160 City Estimate Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: 0 Complete Review D Other PLAN CHECK NO.: 03-756 DATE: March 24, 2003 TYPE OF CONSTRUCTION: VN Reg. VALUE ($) Mod. 3,840 3,840 $53.49! $34.771 D Structural Only 0 Repetitive Fee c=-iRepeats D Hourly I Hour * $29.951 Esgll Plan Review Fee Comments: Sheet of macvalue.doc PLANNINC/ENCINEERINC APPROVALS PERMIT NUMBER CB03-J:S-0 DATE 3/ 31/ () 3 ADDRESS J-Jlf 3 ~QSeg f::aucLiaf RESIDENTIAL TENANT IMPROVEMENT ---~-~ ESIDENTIAL ADDITION MINOR ( < $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLACE FAIRE COMPLETE OFFICE BUILDINC OTHER ___________________ _ PLANNER ________ _ DATE ______ _ ENCi NEE~~ DATE 6/3;/ d3 ' oocstMJsformSr'Plannlng Engineering Approvals ~ ~ D D N M " " ~ ii V • • £ £ u u C C • • 0: 0: PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB 03-TS<o Addressc1J"-/3 PC\SeD Sc,uce.J{l_,L Planner Chris Sexton ___________ _ Phone (7601 602-4624 APN: , ')- Type of Project & Use: . · Net Project Density: ______ _cD=U'l..'/A"'-"C'- Zoning: P-{!_ General Plan: RM Facilities Management Zone: _,_(_2--=-- CFO (in/out) #_Date of participation: ____ Remaining net dev acres: __ _ Circle One (For non-residential development: Type of land used created by this permit: ____________________ _ Legend: IZI Item Complete D Item Incomplete -Needs your action Environmental Review Required: YES NO ✓TYPE __ _ DATE OF COMPLETION: ________ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO ✓ TYPE ___ _ APPROVAL/RESO. NO. _______ DATE __ _ PROJECT NO. _________ _ OTHER RELATED CASES: ____________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: _______________________ _ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES __ NOL CA Coastal Commission Authority? YES__ NO If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (6191 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 21 Complete Coastal Permit Determination Log as needed. lnclusionary Housing Fee required: YES NO~ (Effective date of lnclusionary Housing Ordinance · May 21, 1993.) Data Entry Completed? YES __ NO __ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y /N, Enter Fee, UPDATE!) H:IADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 [i]ltJ □ [i}--[J □ □□□ □□□ Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improverne!1ts, right- of-way width, dimensional setbacks and existing topographical lines (including all ·side and rear yard slopes). 2. Provide legal description of property and assessor's parcel number. Policy 44 -Neighborhood Architectural Design Guidelines 1. Applicability: YES ____ NO ._,/ 2. Project complies YES ___ NO ___ _ Zoning: 1 . Setbacks: Front: Required c)O r Shown ~..J_='~"f~'--- Interior Side: Required -' Shown --=--------Street Side: Required Shown ------- Rear: Required IC) ' Shown c;,a;/,._,';:_-;~--• ___ _ Top of slope: Required _______ .Shown ______ _ 2. Accessory structure setbacks: Front: Required ------~ Interior Side: Required ~ Street Side: Required Rear: Required Structure separation: Required ______ _ 3. Lot Coverage: 4. Height: ',<lr-( Required _"'-_! __ d!,_1-""..L.--- Shown ~~~:~ _;_1_ 4 --z--/~-~ Shown Shown ------- Shown -< .:3() 1 5. Parking: Spaces Required;) Shown -A-=~=----- (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required _______ Shown ______ _ Additional Comments __________________________ _ (' /LluJ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER.._ ~{;, ,k f t:1K-DATE 3-;.,) ½ -03 H;\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01