Loading...
HomeMy WebLinkAbout57C0667L; San Marcos Creek; West Carlsbad Blvd; 2007-03-27Co/trans DEPARTMENT OF TRANSPORTATION Structure Maintenance & Investigations Bridge Inspection Report Bridge Number : 57C0667L Facility Carried: WEST CARLSBAD BLVD Location : 0.5 mi N/0 La Costa Ave City : CARLSBAD Inspection Date : 03/27/2007 Inspection Type Routine FC D Underwater Special Othernn n STRUCTURE NAME; SAN MARCOS CREEK CONSTRUCTION INFORMATION Year Built : 1995 Year Widened: N/A Length (m) : 63.4 Skew (degrees): 0 No. of Joints : 2 No. of Hinges : 0 Structure Description:6 span continuous CIP/RC slab supported by driven PC/PS concrete pile bents (5 per bent) and by open end RC diaphragm abutments on driven PC/PS concrete piles. Span Configuration : (S) 9.0m, 4@11.4m, 9.0m (N) LOAD CAPACITY AND RATINGS Design Live Load.: MS-18+MOD OR HS-20+MOD 32.4 metric tons 54 metric tons PPPPP Type 3 N/A Inventory Rating: Operating Rating: Permit Rating : Posting Load : Calculation Method: Calculation Method: LOAD FACTOR LOAD FACTOR Type 3S2 N/A Type 3-3 N/A DESCRIPTION ON STRUCTURE Deck X-Section: (W) 0.5m br, 11.6m, 0'. 5m br (E) Total Width: 12.6m Net Width: 11.6 m Rail Description: Type 25- concrete Min. Vertical Clearance: Unimpaired DESCRIPTION UNDER STRUCTURE Channel Description: Natural defined sandy bay, riprap bank CONDITION TEXT CONDITION OF STRUCTURE The structure is in good condition. No. of Lanes: 2 Rail Code : 1111 ELEMENT INSPECTION RATINGS F#Elem 101 101 101 101 101 101 101 101 101 38 204 215 226 256 301 302 321 331 Element Description Concrete Slab - Bare P/S Cone Column or Pile Extension Reinforced Cone Abutment P/S Cone Submerged Pile Slope Protection Pourable Joint Seal Compression Joint Seal Reinforced Cone Approach Slab w/ or w/o AC Ovly Reinforced Cone Bridge Railing Env 4 4 4 4 4 4 4 4 4 Total Qty 802 15 25 16 2 26 26 4 153 Units sq.m. ea. m. ea. ea. m. m. ea. m. Qty in each Condition State St. 1 St. 2 St. 3 St. 4 St. 5 802 15 25 16 2 26 26 4 153 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WORK RECOMMENDATIONS - NONE Printed on:Thursday 05/03/2007 07:18 AM 57C0667L/AAAE/10836 Inspected By : M. Zaarour/ G. Zorapapel Registered Civil Engineer Printed on:Thursday 05/03/2007 07:18 AM 57COS67L/AAAE/10836 STRUCTURE INVENTORY AND APPRAISAL REPORT IDENTIFICATION (1) (8) (5) (2) (3) (6) (7) (9) (11) (12) (13) (16) (17) (98) (99) (43) STATE NAME- CALIFORNIA STRUCTURE NUMBER INVENTORY ROUTE (ON/UNDER)- HIGHWAY AGENCY DISTRICT ON 069 57C0667L 150000000 11 99.5 COUNTY CODE 073 FEATURE INTERSECTED- FACILITY CARRIED- LOCATION- (4) PLACE CODE 11194 SAN MARCOS CREEK WEST CARLSBAD BLVD 0.5 mi N/0 La Costa Ave MILEPOINT/KILOMETERPOINT 0 BASE HIGHWAY NETWORK- NOT ON NET 0 LRS INVENTORY ROUTE & SUBROUTE LATITUDE 33 DEC 05 MIN 16 SEC LONGITUDE 117 DEC 18 MIN 46 SEC BORDER BRIDGE STATE CODE % SHARE * BORDER BRIDGE STRUCTURE NUMBER ******!* STRUCTURE TYPE AND MATERIAL STRUCTURE TYPE MAIN:MATERIAL- CONCRETE CONT TYPE- SLAB CODE 201 (44) STRUCTURE TYPE APPR:MATERIAL- TYPE- CODE (45) NUMBER OF SPANS IN MAIN UNIT 6 (46) NUMBER OF APPROACH SPANS 0 (107) DECK STRUCTURE TYPE- CIP CONCRETE CODE 1 (108) WEARING SURFACE / PROTECTIVE SYSTEM: A) TYPE OF WEARING SURFACE- NONE CODE g B) TYPE OF MEMBRANE- NONE CODE 0 C) TYPE OF DECK PROTECTION- NONE CODE 0 *************** AGE AND SERVICE *************** (27) YEAR BUILT 1995 (106) YEAR RECONSTRUCTED 0000 (42) TYPE OF SERVICE: ON- HIGHWAY 1 UNDER- WATERWAY 5 LANES:ON STRUCTURE 02 UNDER STRUCTURE 00 AVERAGE DAILY TRAFFIC 5000 YEAR OF ADT 2000 (109) TRUCK ADT 3 % 2 KM (28) (29) (30) (19) BYPASS, DETOUR LENGTH *************** GEOMETRIC DATA **************** (48) LENGTH OF MAXIMUM SPAN 11.4 M (49) STRUCTURE LENGTH 63.4 M (50) CURB OR SIDEWALK: LEFT 0.0 M RIGHT 0.0 M (51) BRIDGE ROADWAY WIDTH CURB TO CURB 11.6 M (52) DECK WIDTH OUT TO OUT 12.6 M (32) APPROACH ROADWAY WIDTH (W/SHOULDERS) 11.6 M (33) BRIDGE MEDIAN- NO MEDIAN 0 (34) SKEW 0 DEC (35) STRUCTURE FLARED NO (10) INVENTORY ROUTE MIN VERT CLEAR 99.99 M (47) INVENTORY ROUTE TOTAL HORIZ CLEAR 11.6 M (53) MIN VERT CLEAR OVER BRIDGE RDWY 99.99 M (54) MIN VERT UNDERCLEAR REF- NOT H/RR 0.00 M (55) MIN LAT UNDERCLEAR RT REF- NOT H/RR 0.0 M (56) MIN LAT UNDERCLEAR LT 0 .0 M *************** NAVIGATION DATA *************** (38) NAVIGATION CONTROL- NO CONTROL CODE 0 (111) PIER PROTECTION- CODE (39) NAVIGATION VERTICAL CLEARANCE 0.0 M (116) VERT-LIFT BRIDGE NAV MIN VERT CLEAR 0.0 M (40) NAVIGATION HORIZONTAL CLEARANCE 0.0 M 100.0 N/A (112) (104) (26) (100) (101) (102) (103) (105) (110) (20) (21) (22) (37) SUFFICIENCY RATING = STATUS HEALTH INDEX PAINT CONDITION INDEX = ************* CLASSIFICATION ************* NBIS BRIDGE LENGTH- YES HIGHWAY SYSTEM- NOT ON NHS FUNCTIONAL CLASS- MINOR ARTERIAL URBAN DEFENSE HIGHWAY- NOT STRAHNET PARALLEL STRUCTURE- NONE EXISTS DIRECTION OF TRAFFIC- 1 WAY TEMPORARY STRUCTURE- FED. LANDS HWY- NOT APPLICABLE DESIGNATED NATIONAL NETWORK - NOT ON NET TOLL- ON FREE ROAD MAINTAIN- CITY OR MUNICIPAL HIGHWAY AGENCY OWNER- CITY OR MUNICIPAL HIGHWAY AGENCY HISTORICAL SIGNIFICANCE- NOT ELIGIBLE **************** CONDITION *** (58) DECK (59) SUPERSTRUCTURE (60) SUBSTRUCTURE (61) CHANNEL & CHANNEL PROTECTION (62) CULVERTS CODE Y 0 16" 0 N 1 0 0 3 04 04 5 CODE 7 7 N ********* LOAD RATING AND POSTING ********* CODE (31) DESIGN LOAD- MS-18+MOD OR HS-20+MOD 6 (63) OPERATING RATING METHOD- LOAD FACTOR 1 (64) OPERATING RATING- 54.0 (65) INVENTORY RATING METHOD- LOAD FACTOR 1 (66) INVENTORY RATING- 32.4 (70) BRIDGE POSTING- EQUAL TO OR ABOVE LEGAL LOADS 5 (41) STRUCTURE OPEN, POSTED OR CLOSED- A DESCRIPTION- OPEN, NO RESTRICTION (67) (68) (69) (71) (72) (36) (113) (75) (76) (94) (95) (96) (97) (114) (115) **************** APPRAISAL ************J STRUCTURAL EVALUATION DECK GEOMETRY UNDERCLEARANCES, VERTICAL & HORIZONTAL WATER ADEQUACY APPROACH ROADWAY ALIGNMENT TRAFFIC SAFETY FEATURES SCOUR CRITICAL BRIDGES CODE 7 7 N 1111 ********** PROPOSED IMPROVEMENTS * TYPE OF WORK- LENGTH OF STRUCTURE IMPROVEMENT BRIDGE IMPROVEMENT COST ROADWAY IMPROVEMENT COST TOTAL PROJECT COST YEAR OF IMPROVEMENT COST ESTIMATE FUTURE ADT YEAR OF FUTURE ADT CODE 7000 2020 *************** INSPECTIONS *************** (90) INSPECTION DATE 03/07 (91) FREQUENCY 24 MO (92) CRITICAL FEATURE INSPECTION: (93) A) FRACTURE CRIT DETAIL- NO MO A) B) UNDERWATER INSP- NO MO B) C) OTHER SPECIAL INSP- NO MO C) CFI DATE Printed.on:Thursday 05/03/2007 07:18 AM 57C0667L/AAAE/10836