Loading...
HomeMy WebLinkAbout57C0134; Carlsbad OH; Carlsbad Blvd; 2007-10-18Page 1 of 3 DEPARTMENT OF TRANSPORTATION Structure Maintenance & Investigations Bridge Number : 57C0134 Facility Carried: CARLSBAD BLVD Location : 0 . 6 MI NW ELM AVE Bridge Inspection Report City Inspection Date Inspection Type Routine FCn n : CARLSBAD : 10/18/2007 Underwater Specialn n Other STRUCTURE NAME: CARLSBAD OH CONSTRUCTION INFORMATION Year Built : 1925 Skew (degrees) : 45 Year Widened: 1935 No. of Joints : 0 Length (m) : 50.3 No. of Hinges : 0 Structure Description: Five simple CIP/RC "T" beam girder (7) spans on two closed end backfilled RC strutted column (5) bent abutments and on four RC column (5) bents, all supported on RC spread footings. Span Configuration : (SW) 9.8 m, 9.4 m, 8.2 m, 9.4 m, 13 . 7 m (NE) c/c LOAD CAPACITY AND RATINGS Design Live Load: M-13.5 OR H-15 Inventory Rating: 28.1 metric tons Operating Rating: 47.1 metric tons Permit Rating : ppppp Posting Load : Type 3 N/A Calculation Method: LOAD FACTOR Calculation Method: LOAD FACTOR Type 3S2 N/A Type 3-3 N/A DESCRIPTION ON STRUCTURE Deck X-Section: (S) 0.5m br, 5.0m, 4.0m tried, 4.7 m, 1.2 m sw, 0.3 m br (N) Net Width: 13.7 m No. of Lanes: 2 Rail Code : 0000 Total Width: 15.7m Rail Description: Concrete Baluster Min. Vertical Clearance : Unimpaired DESCRIPTION UNDER STRUCTURE Channel Description: None. CONDITION TEXT CONDITION OF STRUCTURE This inspection requested by Eva Plajzer city engineer regarding recommendations from Simon Wong Engineering dated July 30, 2007. There are soffit cracks with light efflorescence at various locations in all the spans. There are 3-5 minor vertical cracks at the face of the girders in span # 1 and # 5. There are spalls at the following locations: Bent cap #4 at easterly end (300mm x 1000mm x 50mm) with exposed rebar. Span #1 at the westerly overhang (300mm x 100mm x 50mm) with rebars exposed. Column #5 of bent #3 (300mm x 100mm x 50mm) at the bottom. Soffit of span #1 bay #3, 2 small spalls (150mm x 200mm x 15mm) with rebars exposed. There are spalls (100mm x 100mm x 20mm average) and cracks in the most of concrete rail balusters. Over all the bridge is appeared to be in good condition. Printed on: Monday 11/19/2007 02:02 PM 57C0134/AAAE/12294 CONDITION TEXT Page 2 of 3 RECOMMENDATIONS Repair the spalls at the verious locations. The cracks will be manoted during the routine inspections ELEMENT INSPECTION RATINGS F#Elem Element Description 101 101 101 101 101 101 101 101 13 110 205 210 215 234 339 359 Concrete Deck - Unprotected w/ AC Overlay Reinforced Cone Open Girder/Beam Reinforced Cone Column or Pile Extension Reinforced Cone Pier Wall Reinforced Cone Abutment Reinforced Cone Cap Concrete Railing (aesthetic/masonry) Soffit of Concrete Deck or Slab Env 4 4 4 4 4 4 4 4 Total Units Qty 680 sq.m. 352 m. 10 ea. 44 m. 44 m. 82 m. 113 m. 1 ea. Qty in each Condition State St. 1 St. 2 St. 3 St. 4 St. 5 680 352 9 44 44 80 88 0 0 0 1 0 0 1 20 1 0 0 0 0 0 1 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WORK RECOMMENDATIONS RecDate Action Work By Status RecDate Action Work By Status EstCost:03/27/2007 Sub-Patch spalls StrTarget: 2 YEARS LOCAL AGENCY PROPOSED 07/30/2004 DistTarget: EA: EstCost: Super-Patch spal StrTarget: 2 YEARS LOCAL AGENCY PROPOSED DistTarget: EA: Patch the spall at column #5 of bent #3 (300mm x 100mm x 50mm) at the bottom. Patch the spalls the following locations: Bent cap #4 at easterly end (300mm x 1000mm x 50mm) with exposed rebar. Span #1 at the westerly overhang (300mm x 100mm x 50mm) with rebars exposed. Inspected By : M. Zaarour Registered Civil Engineer Printed on:Monday 11/19/2007 02:02 PM 57C0134/AAAE/12294 Page 3 of 3 STRUCTURE INVENTORY AND APPRAISAL REPORT IDENTIFICATION (1) (8) (5) (2) (3) (6) (7) (9) (11) (12) (13) (16) (17) (98) (99) STATE NAME- CALIFORNIA STRUCTURE NUMBER INVENTORY ROUTE(ON/UNDER)- HIGHWAY AGENCY DISTRICT ON 069 57C0134 1500S1010 11 COUNTY CODE 073 FEATURE INTERSECTED- FACILITY CARRIED- LOCATION- (4) PLACE CODE 11194 MTDB, BNSF RY, AMTRAK CARLSBAD BLVD 0.6 MI NW ELM AVE MILEPOINT/KILOMETERPOINT 0 BASE HIGHWAY NETWORK- NOT ON NET 0 LRS INVENTORY ROUTE & SUBROUTE LATITUDE 33 DEG 09 MIN 50 SEC LONGITUDE 117 DEG 21 MIN 14 SEC BORDER BRIDGE STATE CODE % SHARE * BORDER BRIDGE STRUCTURE NUMBER ******** STRUCTURE TYPE AND MATERIAL ********* (43) STRUCTURE TYPE MAIN:MATERIAL- CONCRETE TYPE- TEE BEAM CODE 104 (44) STRUCTURE TYPE APPR:MATERIAL- NOT APPLICABLE TYPE- NOT APPLICABLE CODE (45) NUMBER OF SPANS IN MAIN UNIT 5 (46) NUMBER OF APPROACH SPANS 0 (107) DECK STRUCTURE TYPE- CIP CONCRETE CODE 1 (108) WEARING SURFACE / PROTECTIVE SYSTEM: A) TYPE OF WEARING SURFACE- BITUMINOUS CODE g B) TYPE OF MEMBRANE- NONE CODE o C) TYPE OF DECK PROTECTION- NONE CODE 0 *************** AGE AND SERVICE *************** (27) YEAR BUILT 1925 (106) YEAR RECONSTRUCTED 1935 (42) TYPE OF SERVICE: ON- HIGHWAY-PEDESTRIAN 5 UNDER- RAILROAD 2 (28) LANES:ON STRUCTURE 02 UNDER STRUCTURE 00 (29) AVERAGE DAILY TRAFFIC 20000 (30) YEAR OF ADT 1990 (109) TRUCK ADT 1 % (19) BYPASS, DETOUR LENGTH 5 KM *************** GEOMETRIC DATA **************** (48) LENGTH OF MAXIMUM SPAN 13.7 M (49) STRUCTURE LENGTH 50.3 M (50) CURB OR SIDEWALK: LEFT 0.0 M RIGHT 1.2 M (51) BRIDGE ROADWAY WIDTH CURB TO CURB 13.7 M (52) DECK WIDTH OUT TO OUT 15.7 M (32) APPROACH ROADWAY WIDTH (W/SHOULDERS) 13.7 M (33) BRIDGE MEDIAN- CLOSED (NO BARRIER) 2 (34) SKEW 45 DEG (35) STRUCTURE FLARED NO (10) INVENTORY ROUTE MIN VERT CLEAR 99.99 M (47) INVENTORY ROUTE TOTAL HORIZ CLEAR 13.7 M (53) MIN VERT CLEAR OVER BRIDGE RDWY 99.99 M (54) MIN VERT UNDERCLEAR REF- RAILROAD 6.76 M (55) MIN LAT UNDERCLEAR RT REF- RAILROAD 2.5 M (56) MIN LAT UNDERCLEAR LT 0.0 M *************** NAVIGATION DATA *************** (38) NAVIGATION CONTROL- NOT APPLICABLE CODE N (111) PIER PROTECTION- CODE (39) NAVIGATION VERTICAL CLEARANCE 0.0 M (116) VERT-LIFT BRIDGE NAV MIN VERT CLEAR M (40) NAVIGATION HORIZONTAL CLEARANCE 0.0 M SUFFICIENCY RATING = STATUS HEALTH INDEX PAINT CONDITION INDEX 87.1 99.7 N/A ************* CLASSIFICATION ************* (112) NBIS BRIDGE LENGTH- YES (104) HIGHWAY SYSTEM- NOT ON NHS (26) FUNCTIONAL CLASS- OTHER PRIN ART URBAN (100) DEFENSE HIGHWAY- NOT STRAHNET (101) PARALLEL STRUCTURE- NONE EXISTS (102) DIRECTION OF TRAFFIC- 2 WAY (103) TEMPORARY STRUCTURE- (105) FED.LANDS HWY- NOT APPLICABLE (110) DESIGNATED NATIONAL NETWORK - NOT ON NET (20) TOLL- ON FREE ROAD (21) MAINTAIN- CITY OR MUNICIPAL HIGHWAY AGENCY (22) OWNER- CITY OR MUNICIPAL HIGHWAY AGENCY (37) HISTORICAL SIGNIFICANCE- NOT ELIGIBLE **************** CONDITION *** (58) DECK (59) SUPERSTRUCTURE (60) SUBSTRUCTURE (61) CHANNEL & CHANNEL PROTECTION (62) CULVERTS ********* LOAD RATING AND POSTING **** (31) DESIGN LOAD- M-13.5 OR H-15 (63) OPERATING RATING METHOD- LOAD FACTOR (64) OPERATING RATING- (65) INVENTORY RATING METHOD- LOAD FACTOR INVENTORY RATING-(66) (70) CODE Y 0 14 0 N 2 0 0 3 04 04 5 CODE 6 7 6 N N * CODE 2 1 47.1 1 28.1 BRIDGE POSTING- EQUAL TO OR ABOVE LEGAL LOADS 5 (41) STRUCTURE OPEN, POSTED OR CLOSED- DESCRIPTION- OPEN, NO RESTRICTION (67) (68) (69) (71) (72) (36) (113) (75) (76) (94) (95) (96) (97) (114) (115) **************** APPRAISAL **************** CODE STRUCTURAL EVALUATION g DECK GEOMETRY 9 UNDERCLEARANCES, VERTICAL & HORIZONTAL 4 WATER ADEQUACY N APPROACH ROADWAY ALIGNMENT 6 TRAFFIC SAFETY FEATURES 0000 SCOUR CRITICAL BRIDGES N ********** PROPOSED IMPROVEMENTS * TYPE OF WORK- LENGTH OF STRUCTURE IMPROVEMENT BRIDGE IMPROVEMENT COST ROADWAY IMPROVEMENT COST TOTAL PROJECT COST YEAR OF IMPROVEMENT COST ESTIMATE FUTURE ADT YEAR OF FUTURE ADT CODE 28800 2015 (90) (92) A) *************** INSPECTIONS ********** INSPECTION DATE 03/07 (91) FREQUENCY CRITICAL FEATURE INSPECTION: (93) FRACTURE GRIT DETAIL- NO MO A) B) UNDERWATER INSP- NO MO B) C) OTHER SPECIAL INSP- NO MO C) 24 MO CFI DATE Printed on .-Monday 11/19/2007 . 02:02 PM S7C0134/AAAE/12294