HomeMy WebLinkAboutPS 08-27; Scripps Carlsbad Clinic; Sign Permits/Programs (PS),.
City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4610
PLANNING APPLICATION# ft?Of30o21
REC'D BY b ltJA-\\v l"t-
DATE ~·lu·O~
SIGNFEE *¥f-
SIGN PROGRAM FEE----------
RECEIPT NO.-------'---------
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of lllumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
NAME OF PROJECT:
ADDRESS OF PROJECT: ___ .-z,_\_7_C, _ __,$=-=-A-'-t.,-=-\t!--..L.A ........ ~.a....=2._.=----------
ASSESSOR PARCEL NUMBER: __ Z_I;_Z.. __ -_o_Z_l_-_o_l _o_o _______ _
RELATED PLANNING CASE NUMBER(S): _c;'.t:::.....>o<\):....J(_">-=O=-.....>oo<6'-:0~J"-------------
TYPE OF DEVELOPMENT:
(a) Residential (e) Service Station (i) Public Park @ Commercial (f) Prof. Care (j) Produce Stand
Office/Industrial (g) Theater (k) Nursery
(d) llotel/Motel (h) Govt/Church (l) P-U/OS Zone
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA YesD NoD Specific Plan Number
VILLAGE REDEVELOPMENT AREA YesD NoD Requires VR Approval
SIGN ORDINANCE: YesD NoD
COASTAL ZONE: YesO NoD
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Form 10 Revised 12/04 Page I of 4
.·
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes 0 No 0 Date -------
PROPOSED PERMANENT SIGNS:
TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
NUMBER PROPOSED SIGN SIGN SIGN SIGN
ALLOWED AREA AREA HEIGHT HEIGHT
Pole**
Monument** l l t?D 41 (p ~·
Wall 1.. 7/j.. '?O ~"
Suspended
Directional ~ z.. lP ~~ ftl CP'
Canopy
Freestanding**
(Project
_Identity)
PROPOSED TEMPORARY SIGNS:
TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
NUMBER PROPOSED SIGN SIGN SIGN SIGN
ALLOWED AREA AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues. Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard. Page 3 of 4 illustrates an example for what would be require«J for such proposed signs.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Form 10 Revised 12/04 Page 2 of 4
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter. Additional time will be required for on-site inspection.
PIL
Show building Is
• Sight Distance Requirement
• I • : I • • : • :
~ : '\ ___ -l _-~how setbacks from all curbs
Show all property lines
curb line
• • • • • :
PIL • I : •
I •
I • • • • • i • ---
Sight Visibility
21.41.080 Sign design standards
Street N ame(s)
I
I
(i)
North
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Form 10 Revised 12/04 Page 3 of 4
JAN. 1/. Z008 3:18PM HG FENTON NO. 2262 P. 2
UISTINGSlGN PROGRAMS OR. SPECli'IC PLAN SION ClUT£RJA
TOTAJ.. BUJlJ)JNG STRE£T Pl'.ONTA.QB ft.
TOTAl,. SIGNAG! AlLOWANCE sq. ft.
EXISTJNO SlONAOI! (SQ. FT.) cq. A.
aewiNJ.N(J SIGN ALLOWANCE AT PRBSBNT *1•!.
.PllOPOSSD SIONAOE (SQ. FT.) sq. ft.
lt!MA.tNING SIGN ALLOWANCE AfTEa PROPOSED SIGN -------14-ft.
OWNU.
NAME (l'lUNT OR. 'TYPE) NAMi (PJlQtn' Oil TYPE)
~~-~N P~Al (O~NY \t~. ~r-l ~y M~ ktuJr
MAJUNG ADDUSS MAJUNG APlld$8
15~ MlSf)OtJ \Jt\LLEY Ut>. S1E)~ ~.,,.., M\SSIGN VlfLLE.Y ~
ern 1\.!lfl.l STAT& ZIP 1. ~!lONE crtY Alom STATJ %Jt l'ltDHONB
SicN Dtew 0 f1().\08lt;\4\~-0\ ~ ~,0 9l.'O~ ~~.Gt~
t~0-1J8
DA'l'B
PL.OOlf.& CHBCI'lr"E
1. Field chick byplamltr.
2. . w-ithm ~~tAL
3. Styla ~,.,.. -Prosnm-Ddlor Speoif"IC Plau eritaia,. it ~·e.
4. Localic:sc • ba~
'I} l'a ~ lriqle • MnW
s. Polo a4JDOIIUmBDt tip& to be cboc;kecl b)' Tdc ~~ fcrvilblity ilaueL
6. Whoa approve4 route copy tG J)tta !ratD'
APPRO'\'ED: ~ 6cLkJA ~?,-
• • ' • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • a llonn lO l81llcod 12104 Plct4of4
I I
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
/IIIII/II !m ~ IIIII/I ~ lllllllllllll/1/lllm IIIII Ill/~~~
Applicant: HG FENTON
Description Amount
f PSO S 0'0'2 "r' 44.00
2176 SALK AV CBAD
Receipt Number: R0069002 Transaction ID: R0069002
Transaction Date: 03/06/2008
Pay Type Method Description Amount
Payment Check 44.00
Transaction Amount: 44.00
Ci tJ • r'ar lsbad
FaracJctY Lenter
Farada) Cashiering 001
0806601-2 03/06/2008 75
Thu Mrir06,2008 11:30 AM
PERMITS -PERMilS $44.00
T n:1 n Nb r : J80()f~G 1 o z t:.:ri 1 n:u
Tr-ans/flcptff:
$44.0()
$!:4'
SIGNPERMITNO.PS 00 ~z.1
APPROVED BY
t)· Scripps
San Diego, CA
Prepared by
/
corbindesign
People get lost. We fix that. ···
109 East Front Suite 304
Traverse City. Ml 49684
231 947.1236
DATE
All ideas, designs, arrangements and plans indicated or represented by these
drawings are owned by, and property of the Scripps Health and Corbin Design
and were created, evolved and developed for use on and in connection with the
specified project. None of such ideas, designs, arrangements or plans shall be used
by or disclosed to any person, firm or corporation for any purpose whatsoever
without the written permission of Corbin Design and Scripps Health.
These drawings are considered design-intent and are not for construction.
Written dimensions on these drawings have precedence over scaled dimensions.
The further development and engineering of the design-intent drawings is
expected to be shown in the Fabricator's submitted shop drawings. Contractors
shall verify and be responsible for all dimensions and conditions on the job.
Corbin should be notified of any variations from the dimensions and conditions
shown by these drawings prior to the execution of any work, including changes
to graphic designs or typography.
1 I '
------
l
Exterior Signage Carlsbad Clinic 2
Table of Contents
Platform Sign-type Drawings and Details Specifications
Sign Location Plan 3 lx-7a Freestanding Main ID 8 Fabrication Specifications 13
Site Study 4 lx-6 Main ID -Channel Letters 9 Installation 14
Exterior Elevations 5 Entrance-Vinyl on Glass 10 Warranty 14
Graphic Standards 6 Gx-9 Clinic Vehicular Guide 11
Design Array/Sign Messaging 7 Rx-1, 2 Regulatory 12
Exterior Signage Carlsbad Clinic
--~
---
5tt1tJ l.o<A---r-roN • > ACLGpr~i~
~ ";>f-ttx....:.IV lv DE!Io;-d l::>~Av-l •c:!t "8i£Jo . .J
\
/
t--........ -----N89 4221'" 1 .. """-
001 ot;;
lx-7a
I
I
3
Siqn • --t -Plan
Exterior
Carlsbad Clinic
Color I( Au
..&. Entrance
-----
Public Pathways
Public Elevators
Public Stairs
Restrooms
Sign Typ•c t--* lx-6 Main 10
oo lx· 7 Free-standong Main 10
-lx·S Entrance 10 ·Wall-mounted
• Gx-9 Clonic Vehoc. Guo~
e Rx·1.2.3 Regulatory
Oat• •D" 100
05.02.08 I Revised
Master Wayf~ndrng Program
C,)· Scripps
San Diego, CA
>
corbin
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
Exte rior Signage Carlsbad Clinic
San Diego, CA
>
corbin
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
Scale Notes
nts
4
Date Description Elevations
05.02.08 Revised Site Study
Carlsbad
E~terior Signage Carlsbad Clinic
;~·~ ~-~ ~:= -~¥
--~ -" ---~--?
.··T North '·. Atl·:;
t= 14' j
tYscnpps
(Rear) Elevation (Expanded]
/3''-South (Front) Elevation [Expanded] -~·
San Diego. CA
>
corbindesign
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
Scale
3/64" = 1' 0" (on 11" x 17")
5
----
;:. z -----"-=t=--. '_-_---~ -
".__ --
'• . -' ~
~\West Elevation [Expanded] ~ . . -
Notes Date Description Elevations
05.02.08 Revised Elevations
Carlsbad
E :de~rior Signage Carlsbad Clinic
BillSE Color
5« ripps Bl LIE
PPI t-JJON E® 272 8
H o~tt 11elil 5 M P'56 590
311'1 363.5-2 10 D NOO 081
Awrery M-dllli!jl1t Blue A9528-0
P.w•ery Blue A 782 2.-R
:s.,.mbe>ls
0
Parking
= E><it Only
Logo
t )· Scripps
Pdaster Wayfi11ding Program
t )· Scripps
Sa n Diego, CA
2
Scripps Green
PANTONE® 334
Matthews MP56591
3M 3635-210 DN00274
Avery Kelly Green A9670-0
Avery Bright Jade A9679-T
Avery Kelly Green A7825-R
Parking Garage Designator
&
No Parking
>
corbin
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
n
Scripps Orange
PANTONE® 1665
Matthews MP00192
3M 3635-210 DN00275
Avery Orange A9169-0
Avery Orange A7815-R
Parking Lot Designator
4
White
MP N-202
Avery White A9001-0
Avery White A7801-R
Arrow
Black
Matthews MP00833
Avery Black A7090-0
g
Barrier Free
Metallic Silver
Matthews MP18071
Information
Caution Red
PANTONE® 485
Matthews MP00643
Avery Warm Red A9304-0
Avery Warm Red A7814-R
Avery Light Tomato A9324-T
8
Light Blue
PANTONE® Cyan
Matthews MP00832
Avery Olympic Blue A9530-0
Avery Olympic Blue A7821-R
Avery Process Blue A9561-T
Caution Yellow
PANTONE® 110
Matthews MP05856
6
Avery Dark Yellow A9150-0
Avery Yellow A7812-R
• ~ 0 • • 0
No Smoking Pedestrian Path Two-way Traffic
Typography
Myriad Pro -Semibold Condensed
Aa Bb Cc Dd Ee Ff Gg Hh li Jj Kk Ll Mm Nn
Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz
0123456789
Myriad Pro -Bold Condensed
Aa Bb Cc Dd Ee Ff Gg Hh li Jj Kk Ll Mm Nn
Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz
0123456789
Notes
This drawing is design-intent only.
Fabricator is responsible for fabrication
and engineering details not included in
these drawings. Any changes in design,
materials, fabrication method or other
details must be approved by the client
before final fabrication.
CAUTION! COLOR:
CONSISTENT AND ACCURATE COLOR The Pantone Matching System® and
REPRODUCTION ON THIS PAGE CANNOT Matthews Paint system are used for
BE ASSURED DUE TO THE LIMITATIONS OF specifying signage panel color matches.
COLOR COPYING TECHNOLOGY. (In the absence of sign material color chip
reference sets, actual color swatches
should be referenced for color matching.)
Elevator
Shown here are approximations of the
primary signage background colors and
supporting accent colors. Actual color
finishes on signage are to be matte or
low lustre (not shiny or glossy) and
exclusively a premium acrylic
polyurethane.
Stairs Valet
Production Notes
CAUTION!
CONSISTENT AND ACCURATE COLOR REPRODUCTION ON THIS PAGE CANNOT BE ASSURED DUE TO
THE LIMITATIONS OF COLOR COPYING TECHNOLOGY.
Fabricator is responsible for matching all colors and materials as specified and is required to provide
Corbin Design color and material samples for approval prior to fabrication.
COLOR:
The Pantone Matching System® and
Matthews Paint system are used for specifying signage panel color matches. (In the absence of sign
material color chip reference sets, actual color swatches should be referenced for color matching.)
Shown here are approximations of the primary signage background colors and supporting accent
colors. Actual color finishes on signage are to be matte or low lustre (not shiny or glossy) and
exclusively a premium acrylic polyurethane.
ENGINEERING:
Fabricator for provide detailed shop drawings for all components of sign, base and foundation. All
structural elements are to be stamped by a structural engineer licensed in the state of California.
CALIFORNIA (TITLE 24) BRAILLE
Fabricator is responsible for accurately creating Grade 2 Braille in support of the tactile message to
conform with applicable Braille standards. California has its own, unique standard for Braille. Dots
within cells must be 1/10 inch apart, measured from the centers. The cells are 2/10 or 3/10 inch
apart, depending on how you measure. If you measure from the second column of dots to the first
column in the next adjacent cell in the same word, it is 2/10 inch. If you measure from dot to
corresponding dot, it is 3/10 inch. Dots must be 1/40 inch high. Although it is not stated, the
assumption is that dots will have a rounded shape.
ENGINEERING:
Fabricator for provide detailed shop
drawings for all components of sign, base
and foundation. All structural elements
are to be stamped by a structural
engineer licensed in the state of
California.
Date
05.02.08
Description Sign Type Array
Revised Graphic Standards
Carlsbad
Ex te ri or Si g nag e Carlsbad Clinic
Sign 007-norh face Sign 008-east face
• •
Rx-2f Delivery Parking Rx-2d Left Turn Only
non-illuminated non-illuminated
[.t.~aater Wayfinding Program > Scale
3/8" = 1'-0"
" South Entrance
North Entrance
Deliveries
Sign 002-south face
• Gx-9
Clinic Vehic. Guide
Color Palette
C,)· Scripps corbin n (on an 11 x 17 sheet)
San D i~go, CA
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
~Parking ®
1' Salk Avenue
Sign 002 -north face
* lx-6
Main 10
~ South Entrance
1' North Entrance
Deliveries
Sign 003-south face
• Gx-9
Clinic Vehic. Guide
Sign ODS and OOSb
t )· Scripps
Sign 001 -east/west face
00
lx-7
Free-standing Main 10-Medium
This sign type array depicts actual messaging.
Notes
This drawing is design-intent only. Fabricator is responsible for fabrication
and engineering details not included in these drawings. Any changes in
design, materials, fabrication method or other details must be approved
by the client before final fabrication.
Date
05.02.08
Description
Revised
7
Sign Type Array
Carlsbad
Exterior Signage
Exterior Signage Carlsbad Clinic
Side View (Back side)
Master Wayfinding Program
t )· Scripps
San Diego, CA
6'-0" 4'-4 1/2"
>
corbin ign
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
9" 6" cap
Scale
1/2" = 1'-0"
(on an 11 x 17 sheet)
Color Palette
0 -Biue
0 -Green
0 -0range
Top View
4 7 sqft sign face
•
Cfl ps
Front View
See sign type array for actual messaging.
8 L_I ~~
0 L__.I ~
White
Metallic Silver
Fabrication Notes
This drawing is design-intent only. Fabricator is
responsible for fabrication and engineering details not
included in these drawings. Any changes in design,
materials, fabrication method or other details must be
approved by the client before final fabrication.
@ Electrical required
3/16" (th.) fabricated,
two-sided, painted aluminum,
internally illuminated sign
cabinet with radius top and
bottom.
LOGO ILLUMINATION
Scripps symbol and logotype to
be push through white acrylic
with surface applied 3M
perforated dual "color on" vinyL
The entire logo to be full color
during the day and white at
night. Illumination to be as bright
as neon with no hot spots.
Interior of sign cabinet to be
painted white or covered with 3M
light enhancement film.
LOGO PLACEMENT
The entire logo should be scaled
to fit on the sign face and a
margin of 12" should be left
between logo and sign edges.
Logo is centered horizontally and
vertically on the sign panel.
Aluminum fabrication with a single panel for
information (2-sided) Cut-out and push-through
letters. Translucent white acrylic. Copy to glow
white at night.
Font: Myriad Pro Bold Condensed
Footing to be engineered by fabricator.
Electrical Supply Power to be provided to sign
location by electrical contractor.
Stone bed (1/2" round stone) surround to
extend a minimum of 4' beyond sign face with
metal landscape edging to protect sign from
lawn maintenance.
INTERNAL ILLUMINATION
Use GE Tetra PowerGrid LED Lighting System. Number
of modules and power supplies to be determined by
fabricator. Light to project through push-through letters
and perforated side panels. Internal access through
hingeable panels for maintenance to be provided.
Complete lighting details to be provided by fabricator.
Recessed spacer panel painted
metallic silver.
3/16" (th.) painted aluminum
plate with curved top and
bottom edges.
Perforated side panel
1/4" Dia. holes - 3/8" stg Ctrs.
Painted metallic silver with
Day/Night aaytic background panel.
Background to appear white
when illuminated.
1/8" thick aluminium trim
painted metallic silver.
Date Description
05.02.08 Revised
Hexagon screws
Side View (Front side)
Sign Type Array
lx-7a oo
Freestanding Main 10
Medium
8
Exterior Signage Carlsbad Clinic
3'·11 J/8"
2
3'·8 5/8" 1'·11 3/8" • . L'
. ~--········· •······· ........ ~-····j 30 sql't com boned s.gn face
•
Channel Letters
returns pamted to match color of facade
Isometric Color Rendering
Scripps Logo
returns painted to match color of logo
Mll'5,er \\layfmding Program > c: le Color Palette
13 ·S/8"
~ 8'·1/2" -~···························~·····················································] .
s·
.080" thick returns
#6 X .SO"
stainless steel
counter sunk screw
. so· thick diffused
white panel
3M Saipps' Blue
perforated dualfilm
Mounting
Hardware
White LEO lights
Trimless Channel Letter Detail
F bri< 1tio1 ,..ote Date ---,.--t )' Scripps
San Diego, CA
corbin
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
3/4" = 1'·0"
(on an 11 x 17 sheet) 0 -Blue
0 Grttn
0 1 Or~ng~
0 1 Whttf
0 1 Metalh< Silver
This drawing is design·lntent only. Fabricator is
responsible for fabrication and engineering details not
included in these drawings. Any changes in design,
materials, fabrication method or other details must be
approved by the client before fonal fabrication.
@ Electrocal required
ELECTRICAL REQUIREMENTS
While the entire sign should draw about three amps of
power a dedicated 20 amp circuit is recommended. It Is
preferred that no raceway be used.
WEIGHT
The approxomate weoght for a Sign 12' wode os 1 OOib.
05.02.08
LOGO lllUMlNATION
Scripps symbol and logotype to hove
surface applted 3M perforated dual "color
on•. The entire 1090 to be full color dunng
the day and wh1te at night. Illumination to
be as bnght as neon wtth no hot spots.
Interior of s;gn cabinet to be covered with
JM hght enhancement f1lm or with light
enhancement wh•te paint.
fABRICATION
White acrvhc face wtth atumtnum
fabricanon and lntemal lltumtnattOn. t.oQo
returns are to be Pltnted to match the
color of the tace. Chann~ letter returns are
to be pa1nted to match the color of th~
facade. Overall thiCkness to be s·.
Description s;gn Type Array
Revised lx-6 *
9
Main 10 -Channel Letters
Exterior Signage Carlsbad Clinic 10
Mas;ter Wayiinding Program
C)· Scripps
Sa n Diego, CA
I equal --l
I
equal
-.--1----
7 1/2" cap
.......,-----
equal
60" to center
>
corbin sign
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
r-equal ---j
I • I ~
•
=
0 0
=
Sign 004
Scale Color Palette
1/2" = 1'-0"
(on an 11 x 17 sheet)
----------~
This drawing shows actual messaging.
Fabrication Notes
This drawing is design-intent only. Fabricator is
responsible for fabrication and engineering details not
included in these drawings. Any changes in design,
materials, fabrication method or other details must be
approved by the client before final fabrication.
60" to center
I equal I I
e ~;
-
e ual
I 2·-o· -----1
F
0 0
t:::
Sign 006
4 Surface applied opaque vinyl lettering.
Center horizontally and vertically in
window frame.
Font; Myriad Pro, Bold Condensed
I equal I
• •
Date Description
05.02.08 Revised
~ ~ Surface applied opaque vinyl logo. ~ I ~ Center horizontally in window fram•
Sign Type Array
Entrance
Vinyl on Glass
IE)(terior Signage Carlsbad Clinic
3 l/2" cut-out and push-through
translucent acrylic circle.
Mask and spray blue to match
sign face.
Cut-out and puah-through circle
with applied translucent vinyl
circle.
4'-0"
2'-0" 1'-8"
2'-0"
4"
1"
1'-11"
3 1/2"
6 sq ft sign face ---1
'
Top View
3'-0"
See sign type array for actual messaging. '• '• '• '• \.""-----------
Master Wayfinding Program > Scale Color Palette
r )· corbindesign 3/4" = 1'-0" 0 -0 1 Scripps (on an 11 x 17 sheet) Blue
\:...-109 East Front Suite 304 0 0 1 Traverse City, Ml 49684 Green
San Diego, CA 231 947.1236 0 Orange
White
Metallic Silver
Fabricated two-sided aluminum sign
cabinet with radius top and bottom
(fabricated separate from the
information panels) internally
illuminated using GE Tetra PowerGrid
LED System.
1/8" {th.) painted aluminum curved top
and bottom panels.
Cut-out and push-through
letters. Translucent white acrylic.
Font: Myriad Pro, Semibold Condensed
1/4" h painted rule line.
1/8" alum. custom SignComp
changeable message panel with cutout
and push-through white acrylic copy
and graphics (to be routed [if possible]
out of the same sheet of acrylic).
Painted aluminum
Painted tubular aluminum cladding with
capped opening at the top.
Painted 3" square aluminum posts
mounted into a sleeve that is set into
the ground.
Aluminum sleeve embedded in concrete
footing so sign can be installed
independent of footing and bolted to
sleeve. Temporary cap on sleeve must be
installed if sign post is not installed at the
same time.
Footing to be engineered by fabricator.
Stone bed (1/2" round stone) surround to
extend a minimum of 2' beyond sign face
with metal landscape edging to protect sign
from lawn maintenance.
Electrical Supply Power to be provided to
sign location by electrical contractor.
Specifications
ELECTRICAL REQUIREMENTS
While the entire sign should draw -2 amps of power a
dedicated 20 amp circuit is recommended.
Fabrication Notes
This drawing is design-intent only. Fabricator is
responsible for fabrication and engineering details not
included in these drawings. Any changes in design,
materials, fabrication method or other details must be
approved by the client before final fabrication.
@ Electrical required
Redius cap.
Hingeable aluminum framework for ~ internal access into the cabinet.
Radius cap to be removed before
changeable panel can swing upward.
Perforated side panel
1/4" Dia. holes-3/8" stg Ctrs.
Painted metallic silver with
Day/Night acrylic background panel.
Background to appear white
when illuminated.
1/8" thick aluminium trim
painted metallic silver.
Fabricated aluminum sign cabinet
with radius top and bottom.
Side View
INTERNAL ILLUMINATION
Use GE Tetra PowerGrid LED Lighting System. Number
of modules and power supplies to be determined by
fabricator. Light to project through push-through letters
and perforated side panels. Internal access through
hingeable panels for maintenance to be provided.
Complete lighting details to be provided by fabricator.
Date
05.02.08
R 3 5/8"
R 3"
R 2 1/2"
R 3 3/8"
R 2 7/8"
R 2 1/4"
Description
Revised
11
Sign Type Array
Gx-9 +
Clinic Vehicular Guide
E><terior Sig nage Carlsbad Clinic
6'-8"
Top View
Rx-1 Ae<essible Parking
Rx-l a Van Accessible
Mas1er Wayfinding Program
t )· Scripps
San Diego. CA
Reflective vinyl
All white to be
reflective vinyl
Reflective vinyl
Painted aluminum
Center copy vertically
Font: Myriad Pro, Semibold
Condensed
2" square aluminum
post welded to 8" square
3/B" plate mounted to the
concrete floor
>
5'·9"
corbin
109 East Front Suite 304
Traverse City, Ml 49684
231 947.1236
Top View
1'-9"
Rx-1 b Accessible Path Guide
Scale
3/4" = 1 '-0"
(on an 11 x 17 sheet)
Rx-2a Message variations
Painted aluminum angle bracket.
Back of sign to be painted to
match blue.
Painted aluminum
Reflective vinyl
All white to be
reflective vinyl
Reflective vinyl
Center copy vertically
Font: Font: Myriad Pro, Bold
Condensed
Reflective vinyl
2" square aluminum
post welded to 8" square
3/8" plate mounted to the
concrete floor
1'-0"
Top View Single-sided panel fabricated
out of 1/8" {th.) aluminum.
Panel painted to match blue.
Panels are welded to brackets
(Through face mounting Is
not acceptable) and fastened
to posts using stainless
countersunk screws.
Center copy vertically
Font: Myriad Pro, Semibold
Condensed
Painted aluminum
AU white to be
reflective vinyl
1'-0"
Top View
Rx-2d No Entry
All white to be
reflective vinyl
Reflective vinyl
Painted aluminum
Painted aluminum
All white to be
renective vinyl
Rx-2a Reserved Parking Rx-2a Reserved Parking
Color Palette
0 -Biue
0 ~Green
0 ._I _ ____.I WMe
See sign type array for actual messaging.
0 1 -=-I Metallic Silver
0 -Red
0 l ·-:; ·· J LightBiue
Fabrication Notes
This drawing is design-intent only. Fabricator is
responsible for fabrication and engineering details not
included in these drawings. Any changes in design,
materials, fabrication method or other details must be
approved by the client before final fabrication.
Rx-2e Left Turn Only
Sll
Top View
Rx-2b No Parking
Rx-2f Delivery Parking
Date
All white to be
reflective vinyl
Reflective vinyl
Painted aluminum
Center copy vertically
Font: Myriad Pro, Bold
Condensed
Description
05.02.08 Revised
Top View
(square bollard)
6
12
.080 (th.) aluminum
painted bracket with
capped top and bottom,
bolted to parking bolla rd.
Sign face is attached
using high-bond
(VHB tape)
Fabricator to verify
ballard diameter.
.080 (th.) aluminum
painted bracket with
capped top and bottom,
2 bolted to parking bolla rd.
lli 1/2"1 ~~~~g ~~:~~b~~~ched
6 1/S" (VHB tape)
Top View
(round ballard)
Rx-2c Patient Drop Off
Bollard-mounted option
Fabricator to verify
ballard diameter.
Sign Type Array
Rx-1, 2 •
Regulatory
Exterior Signage Carlsbad Clinic
Fabrication Specifications
A. Quality Standards
The materials, products, equipment and performance
specifications described within, establish a standard of required
iunction. dimension, appearance, performance and quality to be
met by the §uccessful Bidder.
B. !itructural Design
Details on de§ign intent drawings indicate a design approach
ior §ign §tructure but do not necessarily include all fabrication
detail> required for the complete structural integrity of the signs,
including consideration for static, dynamic and erection loads
during handling, erecting, and service at the installed locations,
nor do they necessarily consider the preferred shop practices of
the individual Bidders. Therefore, it shall be the responsibility
of the §Uccessful Bidder to perform the complete structural
design and engineering of the signs and to incorporate all the
safety feature§ necessary to adequately support the sign for its
intended use and purpose and to protect the Owner. Successful
Bidder sha II also be re§ponsible for ensuring that all signs meet
local. state and federal codes.
C. Vandalism Design
Fabrication and installation design is to withstand severe abuse
and §ouvenir theft vandalism, but not less than the equivalent of
res;isting simple hand implements and tools (screwdrivers, knives,
coins, keys, and similar items), and adult physical force. All
hardware and fasteners within reach shall be vandal resistant.
D. Substitution
No substitution will be considered unless the Designer has
received written request for approval. Successful Bidder
may recommend equal or better equipment or method, but
will be required, prior to the bid submittal, to provide full
documentation establishing such a substitution's equality or
superiority as measured in the following:
• compliance with the visual design intent;
• cost;
• ease of maintenance; and
• performance.
lhe burden of proof of the merit of the proposed substitute is
upon the successful Bidder. The Owner and Designer's decision of
approval or di§approval of a proposed substitution shall be final.
E. Material Handling
lhe successful Bidder is to pack, wrap, crate, bundle, box, bag,
or otherwise package, handle, transport, and store all fabricated
work a§ necessary to provide protection from damage by
every cau§e. Successful Bidder shall provide clear and legible
i dentiiyi ng information on all product packaging to ensure
proper on-site identification and installation.
F. !iign Specifications: Construction Methodology
The drawing§ call for a variety of fabrication techniques.
Successful Bidders are given leeway to fabricate the signs to
meet the intent of the designs depicted by the drawings.
1. Because different systems of extrusions may result in slightly
different dimensional requirements, the total height and width
dimensions described in the sign construction on the drawings
may be considered "nominal" for the purposes of bid submittal.
2. Sign faces are to be fabricated using aluminum plate of
varying thicknesses, as specified on design intent drawings, with
a minimum thickness of .125 inches unless otherwise noted. Sign
cabinet seams shall be sealed to ensure they are watertight.
3. All finishes are to be satin finish, free from fading, peeling
or cracking. Paint preparation of all exterior metal surfaces of
the sign to include removal of all scratches and imperfections,
sanding and chemical etching. Acceleration of the drying process
is not allowed. Exterior metal surfaces are to be painted as
follows:
• First, substrate should be cleaned and prepped in strict
compliance with Matthews' published recommendations
• Apply two (2) full wet coats of Matthews 74760SP/74766SP
PT Filler, using the wet-on-semi wet method. If additional
coats are required to achieve film build requirements, apply
when last applied coat is still semi-wet. A dry film thickness
(DFT) of .4 to .8 mls is required. (see Matthews Product
Bulletin MPC121)
• Next, apply two (2) coats of a Matthews Paint Acrylic
Polyurethane Satin Topcoat to achieve a DFT of 2 mls. (see
Matthews Product Bulletin MPC1 02)
• Finally, apply two (2) coats of a Matthews Paint Acrylic
Polyurethane Clear Coat containing UV inhibitors to achieve
a DFT of 2 mls, to ensure excellent gloss retention and
protection of the color and substrate underneath. (see
Matthews Product Bulletin MPC178 Satin Clear)
4. All cut-out push-through lettering and shapes shall be routed
from a single piece of acrylic. Routed letters and shapes that
are completed route then bonded to a separate acrylic sheet
are not acceptable. Acrylic shall be routed to a depth that when
pushed-through the sign face, there is a minimum of 1/16" and a
maximum of 3/32" of material beyond the exterior surface unless
otherwise noted. Acrylic is to be attached to the back of the sign
using adhesive, mechanical fasteners, or both depending on the
design specifications.
5. Except where approved otherwise by Owner, conceal
fasteners.
6. Exposed welded joints must be filled and ground smooth so
that there is no seam visible when painted.
7. Non-welded joints between various portions of signs must
have a tight, hairline-type appearance, without gaps. Provide
sufficient fastenings to preclude looseness, racking, or similar
movement.
8. Provide drain holes as needed to prevent accumulation
of water within signs. Holes must be inconspicuous and be
in inconspicuous locations; holes must be located such that
drainage does not occur onto signs, or other surfaces subject
to staining. Provide internal system of baffles to prevent "light
leaks" through drain holes of illuminated signs. Provide color-
coordinated insect screening over drain holes.
9. Non-illuminated sign faces are to have lettering and graphics
created as mask and spray or surface-applied vinyl typography
using Avery or 3M exterior grade, minimum 5-year warranty.
Certain applications are to be engineer-grade reflective vinyl as
specified on the design intent drawings.
10. Visible metal joints must adhere to a fit tolerance of .01".
11. Unlit channel letter faces must be a minimum of .125"
aluminum unless otherwise noted. Channel letter returns must
be .080" aluminum.
G. Sign Specifications: Illumination & Electrical
1. It shall be the responsibility of the sign fabricator to perform
the complete electrical design for illuminated signs. Major
illuminated signs shall be designed by an electrical engineer and
shall be fabricated and wired to be compliant with current UL
listing requirements.
2. All internally illuminated sign cabinets are to have an access
panel that is tight fitting, lightproof and waterproof. Access
panels are to be in an accessible location, out of sight, and shall
be shown on shop drawings.
3. Internally illuminated signs are to have adequate internal
system of ventilation to assure a uniform dissipation of heat
from electrical components of electrically powered and
illuminated signs, heat (solar) absorption by sign and other
sources. Any openings in exterior surfaces must be internally
baffled to prevent light leaks and prevent entry of rain, snow,
wind-blown debris, and other foreign matter, and are to be
covered with interior color-coordinated insect screen.
4. Only labels required by law are permitted to be mounted
on the exterior of the sign face, and they shall be located in a
position that is as discreet as possible.
5. All internally illuminated interior metal surfaces shall be
painted white using Matthews' reflective white paint, or shall
be lined with 3M's Matte White Light Enhancement Film, to
enhance and evenly distribute light.
6. All electrical components shall be built to be housed within
sign cabinets. All wiring and raceways within the sign are to be
completely enclosed. Internal illumination by lamps is required
to provide adequate and even illumination over the face of the
sign without hot spots or shadows. "Halo" effects, "spreading"
or similar light spill due to excessive transmission of the backlight
source shall be minimized.
7. Illumination to be provided by exterior UL rated LED only, (as
specified on design intent drawings). Lamps or other internal
hardware must not be visible through the translucent letterforms
and graphics.
8. All internally illuminated exterior signs are to have their own
electric eye on/off control to turn the sign on at night and off in
13
the morning. The successful Bidder is to submit specifications for
the electric eye with the bid, which the Owner will approve prior
to installation.
9. Verify location of power provided by others prior to sign
fabrication.
11. Face-lit channel letters shall be trim less. Internally illuminated
channel letters shall be illuminated using neon, unless otherwise
noted on the design intent drawings. Transformers for channel
letters shall be remote transformers wherever possible. If remote
transformers are not applicable, then all electrical components
shall be contained within the channel letter itself. Raceways are
not acceptable unless specifically noted on the design intent
drawing or if approved by the Designer prior to bid return. All
raceways must be painted the same color as the wall on which
the sign will be mounted. Channel letters to be painted on the
inside with Matthews' reflective white paint, or lined with 3M's
Matte White Light Enhancement Film to enhance and evenly
distribute light.
I. Fonts/Typefaces
The fonts used for this project were selected specifically for this
project by the Designer and Owner, and include those listed in
the graphic standards.
It is the responsibility of the fabricator to purchase the fonts.
No substitution of any other typefaces may be made. Under
no circumstances are typefaces to be electronically distorted
("squeezed" or "extended") for purposes of fitting to the
specified sign or general alteration of the sign face composition
unless noted in the drawings. This includes (but is not limited to)
stretching, squeezing, tilting, outlining or shadowing.
1. Allletterforms, symbols or graphics shall be reproduced
either by photographic or computer-generated means. Hand-
cut characters are not acceptable. Cutting shall be done in such
manner that edges and corners of finished letterforms will be
sharp and true. Letterforms with nicked, cut, ragged, rounded
corners, and similar disfigurements will not be acceptable.
2. All letterforms shall be made from material and gauge
as indicated on design intent drawings. Typefaces shall be
replicated as indicated on the drawing.
3. Silk-screened and vinyl copy is to match the sheen of the copy
panel background (satin). Edges of letters shall be straight and
corners sharp. Surface of letters shall be uniform in color finish,
and free from pinholes and other imperfections.
4. Silk-screened images shall be executed with photo screens
prepared from original art. No hand-cut screens will be accepted.
Original art shall be defined as artwork that is a first generation
reproduction of the specified art.
EJ<"'terior Signage Carlsbad Clinic
Fabrication Specifications
5. Silk-s<reening shall be highest quality, with sharp lines
and no >awtooths or uneven ink coverage. Screens shall be
photographically produced. Application of inks through screens
»hall <onsi>t of one flood pass and one print pass. Images shall
be uniform in color and ink thickness. Images shall be free from
!iqueegee marks and lines resulting from improper print stroke
or s<reen off contact height. Signs shall be placed in adequate
drying racks with minimum of 2 inches between racks for ample
airflow. Sign rack> shall have system of forced airflow between
la)'ers to provide proper drying and curing of inks. After signs
have dried completely according to the ink manufacturer's time
allowance, signs may be packaged.
6. "Pushed-through" copy must fit accurately into routed
p-ortions of cabinet with tight, hairline joints and snugly into
back -of formed (channel) letters.
-;_The edges and corners of routed letterforms shall be sharp
and 1rue. Letterforms with nicked, cut, ragged, rounded (positive
or negative) corners, and similar disfigurements will not be
acceptable. Letteriorms shall be aligned so as to maintain a
ba!ie line parallel to the sign format, with margins and layout
as indicated on design intent drawings and approved shop
drawings_ Vertical strokes shall be plumb. Mechanically fasten
andJor chemically bond center of letters to acrylic plastic as
described in the design intent.
8. Vinyl graphics and letterforms shall be computer-cut.
I n stallatio n
A. P-ermi1s and Variances
>uccessful Bidder shall be knowledgeable of relevant local code
requiremen1s and honor same in fabrication and installation.
Where applicable, it is the responsibility ofthe successful Bidder
io secure any and all necessary permits for signage installation.
It i> the responsibility of the Owner to secure variances, should
ilny be required. It is the Owner's responsibility to call the
ilppr-opriate agency to have all underground utilities properly
locaied and marked. Any damage to below-grade utilities or
~iruciure> is the responsibili1y of the successful Bidder.
II. !:iite Yi!iit
Prior to i nsta llati on of the signs, the successful Bidder is to visit
ihe proposed site to observe existing conditions and verify all
signage required and its location with Owner. Certain signs may
be locaied on sloped grades and may require uneven footings
f-or each po>t. Site-verify all locations to determine special
requirements for footing templates, if required.
At this time, each sign location shall be staked. The final Sign
Message Schedule and Sign Location Plan shall be consulted
together to determine the precise location for each sign.
C. Installation Subcontractors
If the successful Bidder will use a subcontractor to perform
signage installation, the successful Bidder must provide a
company representative to act as an on-site supervisor to oversee
this work.
D. Masonry/Footings
Any concrete bases for signage are to be poured in place and
are to extend beneath the frost line, or deeper to meet code.
Concrete and reinforcement specifications shall be shown on
shop drawing submittals. The successful Bidder is responsible
for the necessary templates, mounting plates and hardware for
concrete and masonry bases. A minimum 2' rock bed or concrete
pad must be added around each concrete base as protection
from landscaping maintenance as specified on the drawings.
All masonry (concrete block, poured concrete, brick, slab, veneer,
mortar, etc.) is to be properly treated and protected to maintain
the structural integrity of the masonry work with exposure to
all environmental conditions found at the site. For exposed or
visible masonry, this shall include the application of protective
sealers or similar finishes to diminish the effects of close-
proximity sprinkling or irrigation systems.
Signs are to be mounted on J-bolt footings unless otherwise
specified in the design intent drawings, engineered per code.
F. Wind Load
Signs, banners and mounting devices shall be engineered to
withstand a minimum 30-psf wind load normal to the sign,
or greater as per local code, in addition to the weight of the
sign. The successful Bidder shall determine appropriate method
of anchoring signs to the locations specified to meet these
requirements as well as all local code requirements.
E. Mounting
All signs to be mounted level and true. All exposed hardware
is to be touch-up painted on site as required. All bolts, nuts,
washers, or other fasteners shall be stainless or galvanized steel.
While sign type drawings may specify or indicate possible
mounting and/or mounting hardware details, the successful
Bidder will be able to substitute equal or better hardware and
techniques, based upon their experience with similar mounting
situations and as long as the visual appearance of the sign is not
compromised from that shown in the design intent drawings.
All signage products must be installed such that there are no
misalignments between visible components. Sign elements
intended to be removable or changeable after installation must
function as intended without binding, sticking or blocking. It
will be the responsibility of the successful Bidder to correct any
installation misalignments at no charge.
Successful Bidder and their installers are expected to have
knowledge of ADA mounting guidelines, general sign locating
practices, and any particular unique installations defined by
Designer. It is the desire of the Owner that the successful
Bidder follow these guidelines as well as architectural cues in
installing for the best visual placement, keeping a reasonable
distance from protruding objects. Any signage that is improperly
located is to be moved to the proper location by the successful
Bidder, and repairs to wall surfaces and signage are to be at the
successful Bidder's expense.
If the installers are unable to make a decision about any sign
locations, they can contact the Designer, providing a graphic
representation of the questionable area, or contact the Owner
for on-site options.
G. Electrical
The Owner will be responsible for providing a power source
to within 10 feet of the base of each sign requiring power
(either at grade or below grade). Power is to be 120 or 277 (LED
illumination should be 120) volts at 60 cycles unless otherwise
noted in the documents. It is the responsibility of the successful
Bidder to manipulate the existing conduit to its proper location,
install an external disconnect, extend the conduit through the
concrete base (or posts) to align with the point of hookup, and
run the power supply through it. Conduit running from the
disconnect to the sign shall travel within the concrete base, not
on its surface.
H. Punchlist
It is required that the successful Bidder complete a walk through
with the Owner immediately following installation to identify
any errors, such as construction or installation issues. Such errors
are to be corrected in a timely manner, and to the satisfaction of
the Owner.
J. Site Safety and Restoration
During the installation period, successful Bidders and
subcontractors are responsible for their own safety, and are
expected to maintain a safe environment for pedestrians.
Successful Bidders and subcontractors are to keep the Owner's
premises and the adjoining premises, driveways and streets
clean and clear. Job site shall be left safe, neat and clean at
the completion of each day's operation. Successful Bidders and
subcontractors are also expected to temporarily maintain old
signs in order to continue their directional and identification
functions, as well as to maintain signage that meets MUTCD
standards during the installation period. At the completion
of work, successful Bidder and subcontractors shall remove
all rubbish, tools, equipment, and surplus materials, from and
about the premises, and shall leave the site as originally found.
Successful Bidder shall be responsible for repairing or correcting
damage to other contractors' work resulting from successful
Bidder's work.
Warranty
A. Signage Warranty
The successful Bidder is to provide a written five (5) year full
replacement warranty to the Owner that all signs will be free
of defects due to craft work and materials including, but not
limited to:
14
1. Bubbling, chalking, rusting or other disintegration of the sign
panel, graphics or of the edges.
2. Corrosion appearing beneath paint surfaces of panels,
brackets, posts or other support assemblies (except as an obvious
result of vandalism or other external damage).
3. Corrosion of fasteners.
4. The assemblies not remaining true and plumb on their
supports.
S.Fading, chalking and discoloration of the colors and finishes
within the vinyl and paint manufacturer's stated warranty
period.
6. Peeling, delamination or warping ("oil canning").
7. Repair and reinstallation of signage due to failed mountings.
Successful Bidder shall also extend in writing to the Owner all
manufacturers' warranties.
B. Repair or Replacement
Without additional cost to the Owner the successful Bidder shall
repair or replace, including installation, any defective signs or
hardware which develop during the warranty period and repair
any damage to other work due to such imperfections. The
successful Bidder will be required to fully replace all signs that
are in error relative to the working documents (sign message
schedule and sign type drawings) that will be submitted to the
successful Bidder upon award of contract.