Loading...
HomeMy WebLinkAboutPS 07-53; Wachovia; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION # ?S "^3 REC'D BY Qorncu\ Q UJLA^ DATE J ^1=^1 U SIGN FEE vfe^^) SIGN PROGRAM FEE. RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4;00 p.m. Average processing time: 2 weeks L -y- CA RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (b) Commercial (c) Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA (e) (f) (g) (h) Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone YesD VILLAGE REDEVELOPMENT AREA YesQ I^IGN ORDINANCE: YesR COASTAL ZONE: YesD No m No • No • No ^ Specific Plan Number Requires VR Approval Form 10 Revised 12/04 Page 1 of 4 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole o Monument 0 Wall / Suspended Directional Canopy Freestanding (Project Identity) S7 -s^ Z'^- PERMITS ISSUED FOR EXISTING SIGNS: Yes • No • Date PROPOSED PERMANENT SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** Monument** O V ^ Wall 1 Suspended \ Directional S \ Canopy Freestanding** (Project Identity) i \ PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** r For Sale** ^ Banner _i 3.^ 7^" **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. ********* Form 10 Revised 12/04 • • • • • Page 2 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL SIGNAGE ALLOWANCE //f ^ ft. REMAINING SIGN ALLOWANCE AT PRESENT REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN sq. ft. W'il sq.ft. sq. ft. ^5:^^ sq.ft. sq. ft. NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRESS s.^^ "3:" S-r sr-6-2<i-i^?^ CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE I CERTIFY THAT 1 AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. 1 CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE SIGNATIRE DXTE' PLANNER CHECK LIST: 1. 2. 3. 4. 5. 6. Field check by planner. Within maximum length, area. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. Location: • In right-of-way • In visibility triangle at comer Pole and monument signs to be checked by Traffic Engineering, for visibility issues. When approved route copy to Data Entry APPROVED: Planner: 0 Date: (p-\3-0~l *************************************** Form 10 Revised 12/04 Page 4 of 4 Wachovia Bank, N.A. Corporate Real Estate 401 S. Tryon Street Charlotte, NC 28288-0340 Memo W5kCHoviA March 24, 2007 Address: 6998 El Camino Lacosta CA 92009 RE: Wachovia-World Savings Signage Permit Authorization As part of the Wachovia-Golden West Signage Conversion Project, Wachovia Corporate Real Estate has engaged Quiel Bros, to submit and obtain permits at all locations in Southern California. Please be advised that the holder of this letter is a representative of Quiet Bros, and is authorized by Wachovia Corporate Real Estate to perform the above mentioned work at Wachovia-Golden West World Savings Bank location. Respectfully, Michael J. Schebece Project Manager Wachovia Corporation Conversion City of Carlsbad Faraday Center Faiaday Cashiering 001 0714201-2 05/22/2007 33 Tue May22,2007 11:27 AM PtRMITS - PLRMIIS $40.00 Tran NOr: 071420102 0011 0012 Trans/Rc.pt#; R00e4523 SET #: PSC70053 1 1TF.M(S): TOTAL: $40.00 Check {Cnk# 7028) $40.00 Total Received: $40.00 Have a nice day: r,*t**»t:+**++**COSTCMER CCPV***+********^ City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: DARYL BRICKMAN Description PS070053 Amount 40. 00 Receipt Number: RO064528 Transaction Date: 05/22/2007 Transaction ID: R0064528 Pay Type Method Description Amount Payment Check 40.00 Transaction Amount: 40.00 SIGN INDUSTRIES CORPORATE OFFICE 360 CRIOEfi AVENUE MOORESTOWN NJ 08057 • FLORIDA 2416 SAND LAKE ROAD ORLANDO, FL 32609 - TEXAS - SERVICE CENTER 460 SOUTH 8ELTUNE ROAD SUPTE IRVING, TX 7E06C - NORTH CAROLINA 120 CASCADE DRIVE CONCORD, NC 20027 - TEXAS 7303 BURLESON ROAD, SUITE TOli AUSTIN. TX 76744 Existing Sign Inventwy SIGN SCHEDULE Proposed Sign Inventoiy SITE PLAN 2 ItlLTi BUM Sgn &i2seo ? UL-20B-RftC Linear Charriel Letters 3 DFOrsctimal '6129B0 3 •36 OFOrealcrd 612960 4 BAG-PYLOfW^FACOJST PylcnBag 612960 5 BAG-UL-20 Oansl Letter Bag '612960 f. RESBG-3-12 Reetaalffi Bemer 612960 7 ELECIRC BKtiicfa-Ste 612960 8 UVCSCARNG LaxiscapngftrSlte 612983 9 RESTDRWtCN F^o^icnforSte SIGN PERMIT NO. PS .^ilzS^ PID 612980 La Costa, CA PLANNING RUTLDING -07 Site Plan Key o Pylon D Exterior Wall Plac^ue Monument n Informational Sign a Channel Letters ATM ea Non-lllum Letters © Special Flat wall sign X Remove Curved wall sign © Welcome Sign O Directional B Clearance o Blade B1' CD 16' set bacl( REVISION NOTES 1, reface pylon m07 mill El Camino Real ^ ^ 5 ' ^ P THIS IS AN ORIGINALUNPUeUSHEDDRAWINGCREATEDByNWSIGN INDUSTRIES, INC. ITISPROVIDEOFORTHEEXCLUSIVEUSEBVTHECUSTOMERANDFORTHEPROJECTNAMEOINTHIS TITLE BLIKK. IT SHALL NOT BE PROVIDED TO ANY OTHER SIGN MANUFACTURER OR USED FDR ANY OTHER PROJECT WITHOUT THE WRITTEN PERMISSION OF NW SIGN INDUSTRIES, INC. THISORAWINGISAN INSTRUMENT OF SERVICEANDSHALL REMAIN THEEXCLUSIVEPROPERTYOFNWSIGN INDUSTRIES. INC. 4/19/07 DESIGNER: SALES REP: TOTAL PAGES: mlh MM 6 WVCHOVIA NW SIGN INDUSTRIES Mo'l°Ri^a"rofo57 Corporate OlllCe (856) 8O2-1677 • fax: (856) 802-0412 ^.j^gigM iNDCsi5iS| 6988 El Camino Real La Costa, CA 612980 ©NW SIGN INDUSTRIES, INC. 2007 NW SIGN INDUSTRIES CORPORATE OFFICE 360 CRIDER AVENUE MOORESTOWN NJ DM57 - FUDRIQA 2416 SAND LAKE ROAD ORLANDO, FL 32009 - TEXAS - SERVICE CENTER 460 SOUTH BELTLINEROAD SUITE 442 IRVING, TX 7S06C - NORTH CAROLINA 120 CASCADE DRIVE CONCORD, NC 26027 - TEXAS 73D3 BURLESON ROAD. SUITE 706 AUSTIN. TX 78744 JJW SIGN INDUSTRIES CORPORATE OFFICE 360 CRIDER AVENUE MOORESTOWN NJ 0B057 - FLORIDA 2416 SAND LAKE ROAD ORLANDO, FL 32B0B - TEXAS - SERVICE CENTER 460 SOUTH BELTUNE ROAD SUfTE 442 IRVING, TX 7E080 • NORTH CAROLINA 120 CASCADE DRtVE CONCORD, NC 2B0Z7 - TEXAS 73C3 BURLESON ROAD. SUITE 706 AUSTIN. TX 78744 • £ _ Existing ilium Pylon Proposed Pylon Electrical Rei^uiremgnts: -Verify power is stable for new sign Landecapma Requirements: -remove palms and replace with low ground cover 24" OO I ID Repaint existing sign case 085 645 blue New plex face with applied 2nd surface applied 3630-137 blue background, with applied trans 3630-156 green SC 60% 3635-70 Diffuser. Re-use existing 8" pole cover with 24"wide aluminum cladding finished 085642 silver Reface D/F Ilium Pylon ^(tp'^J^ scale: 3/6"=1'-0" 7-427-1 6988 El Camino Real La Costa, CA 612980 NW SIGN INDUSTRIES CORPORATE OFFICE 360 CRIDER AVENUE MOORESTOWN NJ D80E7 - FLORIDA 2416 SAND UKE ROAD ORUNDO, FL 32609 - TEXAS - SERVICE CENTtR 4B0 SOUTH BELTLINE ROAD SUITE 442 IRVING, TX 7ED6D - NORTH CAROLINA 120 CASCADE DRIVE CONCORD, NC 28027 - TEXAS 73C3 BURLESON ROAD, SUITE 706 AUSTIN, TX 78744 SIGN INDUSTRIES CORPORATE 0 FFICE 360 CRIDER AVENUE MOORESTOWN NU OM57 - FLORIDA 2416 SAND LAKE ROAD ORLANDO, FL 32floB • TEXAS - SERVICE CENTER 460 SOUTH BELTLINE ROAD SUITE 442 IRVING, TX 76060 • NORTH CAROLINA 120 CASCADE DRIVE CONCORD, NC 2B027 - TEXAS 73C3 BURLESON ROAD. SUITE 706 AUSTIN, TX 76744 • Restoration area 191 sqft Existing Ilium Wall Sign Proposed Elevation "Fieiii managerto verffy exact measurement Channel Letters - LIL-2OB-RAC scale: I/E"=1'-0" Silver jewelite Keyline - 5/16" 3030-157 European Blue vinyl KEYUNE DETAIL Electrical Ket^uirements: -Use existing power 07-427-1 WVCHOVlA ADDRESS: gggg g| Qg^j^p pggi La Costa, CA 612980 ©NW SIGN INDUS1HIES, INC, 2007 NW SIGN INDtSTRlES j J NW SIGN INDUSTRIES CORPORATE OFFICE 360 ORDER AVENUE MOORESTOWN NJ0ME7 FLORIDA 2416 SAND LAKE ROAD ORUNDO, FL 32808 • TEXAS - SERVICE CENTER 460 SOUTH BELTLINEROAD SUITE 442 IRVING, TX 7E06D - NORTH CAROLINA 120 CASCADE DRIVE CONCORD, NC 28027 - TEXAS 73C3 BURLESON ROAD. SUITE 706 AUSTIN. TX 76744 T I u z I Trim cap edtfiui Typical acrylic letters face aluminum fabricated lyplcal Uluminated neon tube llShtlnit Neon tube supports Electro BR short sfeeve/SSW etedrode comedor 1/4" diameter drahude holes Exterior Of Bufldmg Exterior Mai Disconnect switch r'x2"x 1/4" steel arntledips lyplcal Vi" lafis to studs Steel conduit wall pass thru lypfcal "r lx>x provided others Steel conduit 120 volt power supplK provided byothers Metal raceway lyplcal VI" lafls to studs 2"x2"xl/4"steel aniHedlps BUIdlniitvood studs Typical installadon Section / Ul 48-TiD Interior of Building Scale i W-r-OT" Illuminated Channel Letter Remote D-ansfomier Installation 120 Volts Primary / 20 Amp Electrical Qrcult Load Not To Exceed 16 Amps 80 % Load Factor National Electrical Code / Electrical SIflns - Article 1- 600 All signs shall be constructed In accordance with Underwrites Testing Laboratories. After installation the signs shall be visibly marked with the fallowing 1. Manufactures Name 2. Underwriters Label of Approval 3. Input Vbltage and Amperage All electrical to conform to \dtjonal Hetlntal Code ( C.C.K. ), Pari 3 , Title 24 C.C.R. Electrical requirements Type A stucco exterior wall wood framed walls Type B concrete exterior walls TypeC Dryit extedor wall metal fiamed walls sianftame Stucco 1/4' SCR MM Studs SWnlianie-^ 1VpicalVi'x3Vi"la(2s screws set In per drilled holes, to wood studs lyplcalVi'ionfi Star lead expandinit concrete anchors set bi per drMed holes, to concrete wiidls lyplcal 1/4' Han seirtapplnit screws thru dryll to metal wall studs Note I Minimum atudiments four per ntceway hloncl EfnpLv (909)885-4476 Coach«lla ^Mmy (7IS0)347-837D -Kgh Desert (760)955-7446 Fax: (909)888-2239 • E-McA qwebigns-oom PUBCmSER: PHONE NUMBEft ADDRES& coMPne OIUmBf: SALESPERSON: SERVICE JOB NUMBER: DRMVMQ