Loading...
HomeMy WebLinkAboutDWG 406-2; CUP 02-03; NATIONAL UNIVERSITY; 01-02TRAFFIC STRIPING, PAVEMENT MARKINGS AND PAVEMENT MARKERS 1. THE CONTRACTOR IS RESPONSIBLE FOR ALL SIGNING AND STRIPING. 2. 3. 4. 5. SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO TliE LATEST CALTRANS TRAmc MANUAL, CALTRANS STANDARD SPECIFICATIONS (JULY 1999 OR LATEST VERSION THEREOF), THESE PLANS AND THE SPECIAL PROVISIONS. ALL SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE PUBLIC WORKS DIRECTOR OR HIS REPRESENTATIVE, PRIOR TO INSTALLATION. ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE ENGINEER OF WORK AND PUBLIC WORKS DIRECTOR PRIOR TO ANY CHANGE IN THE FIELD. ALL SIGNING AND STRIPING SHALL BE REFLECTIVE PER CALTRANS SPECIFICATIONS. STRIPING SHALL BE REPAINTED TWO WEEKS AFTER INITIAL PAINTING. SIGNING SHALL USE ENCAPSULATED LENS REFLECTIVE SHEETING (HIGH INTENSITY OR EQUAL). 6. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENITS, ALL STREET STRIPING AND MARKINGS WITHIN A 500' PERIMETER OF THE CONSTRUCTION PROJECT WILL BE RESTORED TO A "LIKE NEW" CONOmON, IN A MANNER MEETING THE APPROVAL OF THE CITY INSPECTOR. 7. EXACT LOCATION OF STRIPING ANO STOP LIMIT LINES SHALL BE APPROVED BY TliE PUBLIC WORKS DIRECTOR OR HIS REPRESENTATIVE PRIOR TO INSTALLATION. 8. CONTRACTOR SHALL REMOVE ALL CONFLICTING PAINTED LINES, MARKINGS ANO PAVEMENT LEGENDS BY GRINDING. DEBRIS SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR. 9. ALL PAVEMENT LEGENDS SHALL BE THE LATEST VERSION OF THE CALTRANS METRIC STENCILS. 10. LIMIT LINES AND CROSSWAUKS SHALL BE FIELD LOCATED. CROSSWALKS SHALL HAVE 10' INSIDE DIMENSION UNLESS OTHERWISE SPECIFIED. 11. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT LEGENDS SHALL BE THERMOPLASTIC UNLESS OTHERWISE SPECIFIED. 12. FIRE HYDRANT PAVEMENT MARKERS SHALL CONFORM TO THE LATEST CALTRANS TRAmc MANUAL AND SAN DIEGO REGIONAL STANDARD DRAWING M-19. 13. ALL MEDIAN NOSES AND FLARES SHALL BE PAINITEO YELLOW. 14. ALL SIGNS SHALL BE STANDARD SIZE AS SHOWN IN THE CALTRANS TRAmC MANUAL UNLESS OTHERWISE SPECIFIED. 15. SIGN POSTS SHALL BE SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SAN DIEGO REGIONAL STANDARD DRAWING M-45. 16. WHEN A SIGN IS ATTACHED TO A POLE, IT SHALL BE MOUNITED USING A STANDARD CITY MOUNTING BRACKET WITH STRAPS. 17. EXISTING SIGNS REMOVED BY THE CONTRACTOR SHALL BE DELIVERED BY THE CONTRACTOR TO THE CITY OF CARLSBAD PUBLIC WORKS YARD AT 405 OAK AVENUE. 18. ALL SIGNS SHOWN ON THESE PLANS SHALL BE NEW SIGNS PROVIDED AND INSTALLED BY THE CONITRACTOR EXCEPT THOSE SIGNS SPECIFICALLY SHOWN AS EXISTING TO BE RELOCATED OR l'O REMAIN. 62562 E,p. 03-31-0 LEGEND AND CONSTRUCTION NOTES: 0 EXISTING TO REMAIN. REMOVE ANO SALVAGE SIGN AND POST (IF APPLICABLE) AS NOTED. RELOCATE EXISTING SIGN(S) TO NEW POST (IF APPLICABLE) AS NOTED. REMOVE ALL EXISTING CONFLICTING TRAFFIC STRIPING, MARKING OR ARROW AS NOTED, INCLUDING RAISED PAVEMENT MARKERS. INSTALL TEMPORARY PAVEMENT MARKERS AND TRAFFIC LINES PER CALTRANS STRIPING DETAIL NOTED. PAINT PAVEMENT MARKING OR ARROW AS NOTED. _._ SIGN (AS NOTED ON PLAN) ,,,,r,,. EXISTING STRIPING 12' CONSTRUCTION LANE DIMENSION (12') EXISTING LANE DIMENSIONS ¢=I DIRECTION OF TRAVEL PROJECT "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJ[CT, THAT I HAVE EX[RCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. FIRM, RBF CONSULTING ADDRESS, 5050 AVENIDA ENCINAS CITY, ST., CARLSBAD, CA 92008 TELEPHONE, (760) 476-9193 BY, DAWN WILSON (NAME OF ENGINEER) R. C. £. NO. ,_6=.:2:.=5c.c6::.2 ________ _ REGISTRATION EXPIRATION DAT£, 03-31-06 DATl':c 10-02-02 SITE PLANNINB ■ DESIIIN ■ CONBTRUCTION ~. 62562 7JAtE EXP. 03-31-06 9795 a • tc»rr MESA BOULEVAAD. 8UTE 100 SAN llEOO. CALFOFNA 92124-1324 C C N S U LT I N G aeaet4.!JOOO • FAX 858.814.5001 • wwwR!F .corn DESIGNED· r.&.k CI-ECKED: C. RODRIGUEZ C. RODRIGUEZ DAWN L. WILSON VICINITY MAP CITY OF OCEANSIDE HIGHWAY PACIFIC OCEAN AVE CITY OF ENCINITAS NOT TO SCALE CITY OF VISTA CITY OF SAN MARCOS •ASBUILT" P.E. __ _ EXP. ___ _ REVIEWED BY: INSPECTOR DATE DATE i---t---t-------------;---+--+----!----I I SH1EET I CITY OF CARLSBAD I SHE2ETS I ENGINEERING DEPARTMENT :=='....':::::========:::'....'::===: DA TE INITIAL DATE INITIAL DA 1E INITIAL ENGINEER Of" WORK REVISION DESCRIPTION 011-iER APPROVAL OTY APPROVAL SIGNING AND STRIPING PLAN FOR: NATIONAL UNIVERSITY CITY ENGINEER DWN BY: __ _ CHKD BY: DI.I!. RVWD BY: A VENIDA ENCINAS PROJECT NO. CUP02-03/C0P02-04 DRAWING NO. 406-2 ' ' . ' E R2(35) F)ROPOSEO NATIONAL UNIVERSITY BLOG. ( \. ______ ____J F W11 - TEXACO BLDG. BLOG. ENGINEER OF WORK Hu~~ IF·~-0~ DA'wN ~SON , R.C.E. 6256 DATE EXP. 03-31-06 ■ ■ ■ CONSULTING C. RmRTGUF7 ---J RRl()G[ a q: 0 Q 8755 CLAIIBAONT MESA BOULEVARD, SUITE 100 SAN DIEGO, CAL~IA 92124-1324 858.814.5000 • FAX 858614.5001 • www.RBF.com O~AWN: CHFCKEC· C. RODR I •3U[Z CAWN L, WI LSU~ --- 1-----1-----+------ DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION ' l_-,IIL,_•_ ........... _......., __ GRAPHIC SCALE 20 I DATE INITIAL OTHER APPROVAL 1 inch = 40 fl "AS BUILT" P.E. __ _ EXP.----DATE REVIEWED BY: INSPECTOR DATE SH2EET I CITY OF CARLSBAD I SHE2ETS ENGINEERING DEPARTMENT SIGNING AND STRIPING PLAN FOR: NATIONAL UNIVERSITY AVENIDA ENCINAS -____, ~======r1=======~ APPR~·--E···D· / L . DA TE INITIAL CITY APPROVAL .,,.--,-2 f),:. ~ ~/~ 7'1' 9'/3~/,,.r /o/2~".11- CITY ENGINEER PE EXPIRES DA TE lWN RY: ___ I Cl IKD DY: 0.!!lt~• R\/WD BY: -· PROJECT NO. DRAWING NO. CUP02-03/COP02-04 406-2