HomeMy WebLinkAboutDWG 406-2; CUP 02-03; NATIONAL UNIVERSITY; 01-02TRAFFIC STRIPING, PAVEMENT MARKINGS
AND PAVEMENT MARKERS
1. THE CONTRACTOR IS RESPONSIBLE FOR ALL SIGNING AND STRIPING.
2.
3.
4.
5.
SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO TliE LATEST CALTRANS TRAmc MANUAL, CALTRANS
STANDARD SPECIFICATIONS (JULY 1999 OR LATEST VERSION THEREOF), THESE PLANS AND THE SPECIAL PROVISIONS.
ALL SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE PUBLIC WORKS DIRECTOR OR HIS REPRESENTATIVE,
PRIOR TO INSTALLATION.
ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE ENGINEER OF WORK AND
PUBLIC WORKS DIRECTOR PRIOR TO ANY CHANGE IN THE FIELD.
ALL SIGNING AND STRIPING SHALL BE REFLECTIVE PER CALTRANS SPECIFICATIONS. STRIPING SHALL BE REPAINTED
TWO WEEKS AFTER INITIAL PAINTING. SIGNING SHALL USE ENCAPSULATED LENS REFLECTIVE SHEETING (HIGH INTENSITY
OR EQUAL).
6. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENITS, ALL STREET STRIPING AND MARKINGS WITHIN A 500' PERIMETER
OF THE CONSTRUCTION PROJECT WILL BE RESTORED TO A "LIKE NEW" CONOmON, IN A MANNER MEETING THE APPROVAL
OF THE CITY INSPECTOR.
7. EXACT LOCATION OF STRIPING ANO STOP LIMIT LINES SHALL BE APPROVED BY TliE PUBLIC WORKS DIRECTOR OR HIS
REPRESENTATIVE PRIOR TO INSTALLATION.
8. CONTRACTOR SHALL REMOVE ALL CONFLICTING PAINTED LINES, MARKINGS ANO PAVEMENT LEGENDS BY GRINDING. DEBRIS
SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR.
9. ALL PAVEMENT LEGENDS SHALL BE THE LATEST VERSION OF THE CALTRANS METRIC STENCILS.
10. LIMIT LINES AND CROSSWAUKS SHALL BE FIELD LOCATED. CROSSWALKS SHALL HAVE 10' INSIDE DIMENSION UNLESS
OTHERWISE SPECIFIED.
11. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT LEGENDS SHALL BE THERMOPLASTIC
UNLESS OTHERWISE SPECIFIED.
12. FIRE HYDRANT PAVEMENT MARKERS SHALL CONFORM TO THE LATEST CALTRANS TRAmc MANUAL AND SAN DIEGO
REGIONAL STANDARD DRAWING M-19.
13. ALL MEDIAN NOSES AND FLARES SHALL BE PAINITEO YELLOW.
14. ALL SIGNS SHALL BE STANDARD SIZE AS SHOWN IN THE CALTRANS TRAmC MANUAL UNLESS OTHERWISE SPECIFIED.
15. SIGN POSTS SHALL BE SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SAN DIEGO REGIONAL
STANDARD DRAWING M-45.
16. WHEN A SIGN IS ATTACHED TO A POLE, IT SHALL BE MOUNITED USING A STANDARD CITY MOUNTING BRACKET WITH
STRAPS.
17. EXISTING SIGNS REMOVED BY THE CONTRACTOR SHALL BE DELIVERED BY THE CONTRACTOR TO THE CITY OF CARLSBAD
PUBLIC WORKS YARD AT 405 OAK AVENUE.
18. ALL SIGNS SHOWN ON THESE PLANS SHALL BE NEW SIGNS PROVIDED AND INSTALLED BY THE CONITRACTOR EXCEPT
THOSE SIGNS SPECIFICALLY SHOWN AS EXISTING TO BE RELOCATED OR l'O REMAIN.
62562
E,p. 03-31-0
LEGEND AND CONSTRUCTION NOTES:
0 EXISTING TO REMAIN.
REMOVE ANO SALVAGE SIGN AND POST (IF APPLICABLE) AS NOTED.
RELOCATE EXISTING SIGN(S) TO NEW POST (IF APPLICABLE) AS NOTED.
REMOVE ALL EXISTING CONFLICTING TRAFFIC STRIPING, MARKING OR ARROW AS NOTED,
INCLUDING RAISED PAVEMENT MARKERS.
INSTALL TEMPORARY PAVEMENT MARKERS AND TRAFFIC LINES PER CALTRANS
STRIPING DETAIL NOTED.
PAINT PAVEMENT MARKING OR ARROW AS NOTED.
_._ SIGN (AS NOTED ON PLAN)
,,,,r,,. EXISTING STRIPING
12' CONSTRUCTION LANE DIMENSION
(12') EXISTING LANE DIMENSIONS
¢=I DIRECTION OF TRAVEL
PROJECT
"DECLARATION OF RESPONSIBLE CHARGE"
I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJ[CT, THAT I
HAVE EX[RCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS
DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT
THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS.
I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY
THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY
RESPONSIBILITIES FOR PROJECT DESIGN.
FIRM, RBF CONSULTING
ADDRESS, 5050 AVENIDA ENCINAS
CITY, ST., CARLSBAD, CA 92008
TELEPHONE, (760) 476-9193
BY, DAWN WILSON
(NAME OF ENGINEER)
R. C. £. NO. ,_6=.:2:.=5c.c6::.2 ________ _
REGISTRATION EXPIRATION DAT£, 03-31-06
DATl':c 10-02-02
SITE
PLANNINB ■ DESIIIN ■ CONBTRUCTION
~. 62562 7JAtE
EXP. 03-31-06
9795 a • tc»rr MESA BOULEVAAD. 8UTE 100
SAN llEOO. CALFOFNA 92124-1324
C C N S U LT I N G aeaet4.!JOOO • FAX 858.814.5001 • wwwR!F .corn
DESIGNED· r.&.k CI-ECKED:
C. RODRIGUEZ C. RODRIGUEZ DAWN L. WILSON
VICINITY MAP
CITY OF OCEANSIDE
HIGHWAY
PACIFIC
OCEAN
AVE
CITY OF ENCINITAS
NOT TO
SCALE
CITY OF VISTA
CITY OF
SAN MARCOS
•ASBUILT"
P.E. __ _ EXP. ___ _
REVIEWED BY:
INSPECTOR
DATE
DATE
i---t---t-------------;---+--+----!----I I SH1EET I CITY OF CARLSBAD I SHE2ETS I ENGINEERING DEPARTMENT :=='....':::::========:::'....'::===:
DA TE INITIAL DATE INITIAL DA 1E INITIAL
ENGINEER Of" WORK REVISION DESCRIPTION 011-iER APPROVAL OTY APPROVAL
SIGNING AND STRIPING PLAN FOR:
NATIONAL UNIVERSITY
CITY ENGINEER
DWN BY: __ _
CHKD BY: DI.I!.
RVWD BY:
A VENIDA ENCINAS
PROJECT NO.
CUP02-03/C0P02-04
DRAWING NO.
406-2
' ' . '
E R2(35)
F)ROPOSEO NATIONAL UNIVERSITY
BLOG.
(
\. ______ ____J
F W11 -
TEXACO
BLDG.
BLOG.
ENGINEER OF WORK
Hu~~ IF·~-0~ DA'wN ~SON , R.C.E. 6256 DATE
EXP. 03-31-06
■ ■ ■
CONSULTING
C. RmRTGUF7
---J RRl()G[
a q:
0
Q
8755 CLAIIBAONT MESA BOULEVARD, SUITE 100
SAN DIEGO, CAL~IA 92124-1324
858.814.5000 • FAX 858614.5001 • www.RBF.com
O~AWN: CHFCKEC·
C. RODR I •3U[Z CAWN L, WI LSU~
---
1-----1-----+------
DA TE INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
' l_-,IIL,_•_ ........... _......., __
GRAPHIC SCALE
20
I
DATE INITIAL
OTHER APPROVAL
1 inch = 40 fl
"AS BUILT"
P.E. __ _ EXP.----DATE
REVIEWED BY:
INSPECTOR DATE
SH2EET I CITY OF CARLSBAD I SHE2ETS
ENGINEERING DEPARTMENT
SIGNING AND STRIPING PLAN FOR:
NATIONAL UNIVERSITY
AVENIDA ENCINAS
-____, ~======r1=======~
APPR~·--E···D· / L .
DA TE INITIAL
CITY APPROVAL
.,,.--,-2 f),:. ~ ~/~ 7'1' 9'/3~/,,.r /o/2~".11-
CITY ENGINEER PE EXPIRES DA TE
lWN RY: ___ I
Cl IKD DY: 0.!!lt~•
R\/WD BY:
-· PROJECT NO. DRAWING NO.
CUP02-03/COP02-04 406-2